Loading...
HomeMy WebLinkAboutB13-0456 REV12 permit and receipt NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ,. 1C?WN OF UAI�'' Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B13-0456 Project #: PRJ13-0342 Job Address: 1027 PTARMIGAN RD VAIL Applied.....: 10/11/2013 Location......: 1027 PTARMIGAN ROAD Issued. . . : 12/01/2014 Parcel No....: 210109209006 OWNER RESNICK, ERIC & SARA 10/11/2013 493 BEAVER DAM ROAD VAI L CO 81657 CONTRACTOR R.A. NELSON &ASSOCIATES INC 10/11/2013 Phone: 970-471-2633 RYAN SMITH PO DRAWER 5400 � AVON CO 81620 License: C000003122 APPLICANT TRIUMPH DEVELOPMENT 10/11/2013 Phone: 303-475-4413 MIKE FOSTER VAI L CO 81657 Description: NEW SINGLE FAMILY RESIDENCE Occupancy: R-3 Type Construction: VB Valuation: $6,490,000.00 .....x........................................................................... FEE SUMMARY .�...,.........._.,..«...,..,,.......<........�>....,,...............,......... Building Permit-----------> $25,647.25 Bldg Plan Check----------> $16,670.71 Use Tax Fee-----------------------> 129,600.00 Electrical Permit---------> $1,311.00 Elec Plan Check-----------> $852.15 Restuarant Plan Review--------> $0.00 Mechanical Permit------> $11,220.00 Mech Plan Check---------> $2,805.00 Additional Fees--------------------> $0.00 Plumbing Permit--------> $2,970.00 Plmb Plan Check---------> $742.50 Recreation Fee--------------------> $1,534.80 Investigation-----------------------> $0.00 � Will Call------------------------------> $20.00 TOTAL PERMIT FEES--------------> 194,418.41 Payments-------------------------------> 194,418.41 BALANCE DUE------------------------> $0.00 ............................................................................>.....,..,...,�,.......,..,,.......,...x.,.........,.............,.............,,<..........,«....,.,..,.. DECLARATIONS I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM -4:00 PM. combination permit_012811 ,�- � � ! i V�{l��� 1 +x..xxxxxx�+�w.�xxx....++.++.x...,r�.�..+..+.«..+.+..w.......+«�.,v+.....++..�w+..x..+...x.x.xr.......«..+.�,e.x..x�aww�+xx.x�xxx+xs,xrxxxxx�t��+.�>rx��xxxxxx�����������w,rw����ww�www.,.w CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF � Permit#: 613-0456 Address: 1027 PTARMIGAN RD VAIL Owner: RESNICK, ERIC & SARA Location: 1027 PTARMIGAN ROAD ..,.,,.x.........................�......,.................,,...........................,............,........,..<.....,,..,.,.,....,.....,.,,.....,,.�...x.......,,.,................ Cond: 1 (FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY WORK CAN BE STARTED. Cond: 51 (FIRE 2007): MONITORED FIRE ALARM SYSTEM REQUIRED AND SHALL COMPLY WITH NFPA 72(2007)AND VFES STANDARDS. Cond: 500 (FIRE): FIRE SPRINKLER SYSTEM REQUIRED AND SHALL COMPLY WITH NFPA 13R(2010)AND VFES STANDARDS. combination permit_012811 . 1 ��T1! U� 1�I1tL ! ***.*„*„***„***«***«***�**********************„*****.********�*�******«�*„******.,�***********************«*„**«.,********************«**********««**** REQUIRED INSPECTIONS AND STATUSES � Permit#: B13-0456 Address: 1027 PTARMIGAN RD VAIL Owner: RESNICK, ERIC & SARA Location: 1027 PTARMIGAN ROAD ****„*******.**..**„**«********„**.**********�***,.,«**„***«************�***�.*******«****.,*,.*****�.***.***.***„***„««�******«******.,****„�*****«****« Item: 00010 BLDG-FOOTING 11/05/2013 By: sgremmer Action: AP 05/30/2014 By: JRM Action: AP Comments: open area north Item: 00020 BLDG-Foundation/Steel 11/15/2013 By: Martin Action: DN Comments: panels in place. Unable to inpsect. Remove panels and call for re-inspection 11/20/2013 By: JRM Action: PI Comments: APPROVED ALL EXCEPT FOR NORTH STAIR AREA AND SPORTS COURT/GARAGE AREA 11/26/2013 By: sgremmer Action: PI 12/11/2013 By: sgremmer Action: PI Comments: stair walls 01/14/2014 By: sgremmer Action: PI Comments: Base for North and East fireplace 04/23/2014 By: sgremmer Action: PI Comments: rebar for stairs 07/17/2014 By: sgremmer Action: AP Comments: pool 09/09/2014 By: sgremmer Action: PI 11/26/2014 By: sgremmer Action: AP Item: 00021 PLAN-ILC Foundation Plan 01/02/2014 By: JB Action: AP Item: 00025 PW-Rough grade 11/25/2014 By: Is Action: AP Item: 00110 ELEC-Service 07/01/2014 By: sgremmer Action: AP Item: 00120 ELEC-Rough 04/23/2014 By: sgremmer Action: PI Comments: all except sport court and mech area 06/04/2014 By: sgremmer Action: PI Comments: Mech room 06/12/2014 By: sgremmer Action: PI Comments: walls for sport court 06/23/2014 By: sgremmer Action: PI Comments: pool conduits 06/24/2014 By: sgremmer Action: PI Comments: pool conduits 07/17/2014 By: sgremmer Action: AP 08/05/2014 By: sgremmer Action: AP Comments: Pool bonding grid 11/18/2014 By: sgremmer Action: AP Comments: bonding for lights in pool Item: 00130 ELEC-Conduit 07/01/2014 By: sgremmer Action: AP 08/21/2014 By: sgremmer Action: AP Item: 00200 MECH-Rough combination permit_012811 � 12/13/2013 By: JRM Action: PI Comments: IN FLOOR HEAT LOWER LEVEL ZONES 1-4 100#AIR TEST 04/23/2014 By: sgremmer Action: PI Comments: heat and chill mains 04/28/2014 By: sgremmer Action: AP 05/30/2014 By: JRM Action: AP Comments: IN FLOOR HEAT GARAGE ONLY 100#AIR TEST 07/24/2014 By: sgremmer Action: AP Comments: Fireplaces living rm, kitchen, mstr bedroom 08/04/2014 By: sgremmer Action: AP Comments: Deck snowmelt 08/05/2014 By: sgremmer Action: AP Comments: Pool deck snow melt 09/03/2014 By: sgremmer Action: AP Comments: fire place 09/09/2014 By: sgremmer Action: PI Comments: driveway snowmelt 09/22/2014 By: sgremmer Action: AP Comments: snowmelt upper deck 09/25/2014 By: sgremmer Action: AP Comments: lower deck snowmelt Item: 00210 PLMB-Underground 11/26/2013 By: sgremmer Action: PI 12/11/2013 By: sgremmer Action: PI Comments: water main mech room to exit of foundation only 04/28/2014 By: sgremmer Action: AP Item: 00220 PLMB-Rough/D.W.V. 04/10/2014 By: sgremmer Action: PI Comments: bar sink not complete 04/28/2014 By: sgremmer Action: AP 06/04/2014 By: sgremmer Action: AP Item: 00230 PLMB-Rough/Water 04/23/2014 By: sgremmer Action: PI 04/28/2014 By: sgremmer Action: AP 06/04/2014 By: sgremmer Action: AP Item: 00240 PLMB-Gas Piping 04/21/2014 By: sgremmer Action: AP � 07/29/2014 By: sgremmer Action: AP Comments: fire pit 08/21/2014 By: sgremmer Action: AP Comments: driveway bullards and fire pit Item: 00310 MECH-Heating 04/28/2014 By: sgremmer Action: AP Item: 00320 MECH-Exhaust Hoods 04/28/2014 By: sgremmer Action: AP Item: 00330 MECH-Supply Air 04/28/2014 By: sgremmer Action: AP Item: 00410 Special Inspect-progress rept 05/22/2014 By: JRM Action: AP Item: 00030 BLDG-Framing 04/07/2014 By: sgremmer Action: PI Comments: behind pocket doors, and duct work at south west corner on main floor only 04/28/2014 By: sgremmer Action: DN Comments: SI reports to be provided Exterior concrete pillars are cracked from ancher bolts provide fix all windows to be in for U-value verificaction Full stud pack for 5 ply LVL in 1 st floor laundry room Letter from engineer recieved for framing see Laserfiche 04/29/2014 By: sgremmer Action: DN Comments: ILC combination permit_012811 and SI reports to be complete 05/21/2014 By: sgremmer Action: PI Comments: Window u-values complete 07/17/2014 By: sgremmer Action: AP Item: 00022 PLAN-ILC FRAMING 05/19/2014 By: JB Action: AP Item: 00050 BLDG-Insulation 12/11/2013 By: sgremmerAction: PI Comments: underslab and exterior foundation 03/12/2014 By: sgremmer Action: PI Comments: exterior foundation and 2" ridged foam paneling 04/07/2014 By: sgremmer Action: PI Comments: roof 6" of lay in ridged foam board only 05/21/2014 By: sgremmer Action: PI Comments: window insulation 05/22/2014 By: sgremmer Action: PI Comments: lower level except sport court, mech room, and AV room 06/04/2014 By: sgremmer Action: PI Comments: main level 06/12/2014 By: sgremmer Action: PI Comments: upper east wing 06/18/2014 By: sgremmer Action: PI Comments: garage, mech rm, AV rm 06/24/2014 By: sgremmer Action: PI Comments: mikes and emmas room 07/01/2014 By: sgremmer Action: AP Item: 00060 BLDG-Sheetrock Nail 06/04/2014 By: sgremmer Action: PI Comments: lower level 06/12/2014 By: sgremmer Action: PI Comments: fire place chase all on main floor 06/18/2014 By: sgremmer Action: PI Comments: fireplace main ivl 06/24/2014 By: sgremmer Action: PI Comments: allies rm 07/01/2014 By: sgremmerAction: PI Comments: upper Ivl except mstr. 07/17/2014 By: sgremmer Action� Pi Comments: mstr and sport court walls 07/29/2014 By: sgremmer Action: AP Item: 00070 BLDG-Misc. 08/12/2014 By: sgremmer Action: PI Comments: drywall boxes for exterior unit heaters rebar for stairs and hot tub 11/26/2014 By: sgremmer Action: AP Item: 00190 ELEC-Final 11/26/2014 By: sgremmer Action: DN Comments: gfci's in mstr bath not working � 125 volt recpts in mech room to be gfci protected closet surface mount fixture to be 12"from shelf . 11/26/2014 By: sgremmer Action: DN Comments: breaker blanks 12/01/2014 By: sgremmer Action: AP Item: 00290 PLMB-Final 11/25/2014 By: sgremmer Action: AP 11/26/2014 By: sgremmer Action: DN Comments: � secure hose bibs label med gas at valves 12/01/2014 By: sgremmerAction: AP Item: 00390 MECH-Final 11/26/2014 By: sgremmer Action: DN Comments: install exhaust terminations combination permit_012811 i 12/01/2014 By: sgremmer Action: AP Item: 00420 Special Inspect-final rept Item: 00540 BLDG-Final C/O 11/26/2014 By: sgremmer Action: DN Comments: fire, planning, and public works to sign off � handrail at sport court stair not installed stairs at storeage area and deck stair non- complient pool gate latch to be on the inside 12/01/2014 By: sgremmer Action: APCR Comments: All life saftey items complete ok for TCO when PW signs off DIA has been submitted Item: 00501 PW-Access/Staging/Erosion 09/02/2014 By: Is Action: AP Item: 00502 PW-Rough Driveway Grade 09/02/2014 By: Is Action: AP Item: 00503 PW-Final Driveway Grade 11/25/2014 By: Is Action: AP Item: 00532 PW-TEMP. C/O 11/25/2014 By: Is Action: DN Comments: Not ready 11/26/2014 By: Is Action: AP Item: 00539 PW-FINAL C/O 11/25/2014 By: Is Action: DN Comments: Not Ready Item: 00533 PLAN-TEMP. C/O 11/25/2014 By: Warren Action: AP Comments: DIA submitted for remaining work. Item: 00534 PLAN - FINAL C/O 11/25/2014 By: Warren Action: DN Comments: Need to complete landscaping. Site was covered in snow uabel to fully identify all remainign work. DIA submitted. combination permit_012811 � +**********************************�*************************************+*************�**** TOWN OF VAIL, COLORADOCopy Reprinted on 12-01-2014 at 09:18:53 12/O1/2014 Statement ***************�*********************+*+***********+**�***�******************************++* Statement Number: R140002033 Amount: $165.00 12/O1/201909: 18 AM Payment Method: Check Init: CG Notation: ck 413041 RA Nelson ----------------------------------------------------------------------------- Permit No: B13-0456 Type: COMBINATION BLDG PERMIT Parcel No: 2101-092-0900-6 Site Address: 1027 PTARMIGAN RD VAIL Location: 1027 PTARMIGAN ROAD Total Fees: 194, 418.41 This Payment: $165.00 Total ALL Pmts: 194, 418. 41 Balance: $0.00 ****************************************************************************+***********��** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ PF 00100003112300 PLAN CHECK FEES 165. 00 -----------------------------------------------------------------------------