Loading...
HomeMy WebLinkAboutB14-0042 REV6 truss approvedRe: The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of this component for any particular building is the responsibility of the building designer, per ANSI/TPI 1. The truss drawing(s) referenced below have been prepared by MiTek Industries, Inc. under my direct supervision based on the parameters provided by Hernandez, Marcos Lion’s Ridge / Bldg 1/ Roof Pages or sheets covered by this seal: R43466472 thru R43466488 My license renewal date for the state of Colorado is Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. October 31, 2015. Alpine Truss-Montrose, CO. 03042-14B 7777 Greenback Lane Suite 109 Citrus Heights, CA, 95610 Telephone 916/676-1900 Fax 916/676-1909 MiTek USA, Inc. December 19,2014 Job 03042-14B Truss A1 Truss Type COMMON Qty 5 Ply 1 Lion’s Ridge / Bldg 1/ Roof Job Reference (optional) R43466472 7.600 s Sep 19 2014 MiTek Industries, Inc. Fri Dec 19 15:03:12 2014 Page 1 Alpine Truss, Montrose, CO - 81401 ID:6H?QcMI6c4e8LHnD43dQbjzXm0O-S33YO0lkRm65m1A0CZNF8Fi25H6Y08wdrl?h7xy7L3D Scale = 1:77.0 A B N C O D E F G P H I M L K J Q R S T U 8x10 10x10 7x10 4x4 4x6 2x4 8x10 8x8 3x8 12x12 3x6 7-6-6 7-6-6 15-0-14 7-6-8 18-3-5 3-2-7 21-11-4 3-7-15 -3-0-0 3-0-0 7-6-6 7-6-6 15-0-14 7-6-8 18-3-5 3-2-7 21-11-4 3-7-15 25-11-4 4-0-0 1- 1 - 0 12 - 4 - 1 1 7- 2 - 1 4 3- 1 0 - 1 0 9.00 12 Plate Offsets (X,Y)-- [B:0-2-0,0-2-10], [E:0-5-0,0-5-4], [F:0-4-0,Edge], [G:0-6-0,0-7-8], [H:0-2-12,0-3-4], [L:0-4-0,0-4-8] LOADING (psf) TCLL (Roof Snow=100.0) TCDL BCLL BCDL 100.0 15.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 NO IBC2012/TPI2007 CSI. TC BC WB (Matrix) 0.92 0.31 0.57 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.06 -0.09 0.03 0.01 (loc) L-M L-M J M l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 328 lb FT = 0% GRIP 118/123 LUMBER- TOP CHORD 2x6 SPF 2100F 1.8E *Except* F-I: 1.5X9.5 Microllam LVL 2.0E TG, B-E: 2x6 SPF 1650F 1.5E BOT CHORD 2x6 SPF 1650F 1.5E WEBS 2x4 SPF 2100F 1.8E *Except* E-M: 2x4 WW Stud, F-L,G-K: 2x6 SPF 1650F 1.5E H-J: 1.5X5.5 Microllam LVL 2.0E TG OTHERS 2x10 DF No.1&Btr LBR SCAB A-D 2x10 DF No.1&Btr one side G-I 2x10 DF No.2 both sides SLIDER Left 2x6 SPF 1650F 1.5E 4-11-2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-10-13 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt E-L, F-L, H-J, G-K MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)B=3096/0-5-8 (min. 0-4-14), J=3958/0-5-8 (min. 0-1-8) Max Horz B=300(LC 27) Max Uplift B=-304(LC 28) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD A-B=-0/637, B-N=-3017/372, C-N=-2538/367, C-O=-2358/346, D-O=-2357/338, D-E=-2026/327, E-F=-1508/405, F-G=-960/466, G-P=-1245/0, P-Q=-1503/0, H-Q=-1561/0, H-R=0/1150, I-R=0/1043, H-J=-3929/0 BOT CHORD B-S=-334/1886, M-S=-214/1886, M-T=-214/1886, L-T=-214/1886, K-L=-598/268 WEBS E-M=0/313, E-L=-1395/46, F-L=-771/0, H-K=-1113/650, G-K=-517/1078, G-L=0/1643 NOTES- 1) Attached 10-6-15 scab A to D, front face(s) 2x10 DF No.1&Btr with 2 row(s) of 10d (0.131"x3") nails spaced 9" o.c.except : starting at 3-6-5 from end at joint A, nail 3 row(s) at 2" o.c. for 2-0-0; starting at 7-7-2 from end at joint A, nail 2 row(s) at 4" o.c. for 2-4-4. 2) Attached 10-0-0 scab G to I, both face(s) 2x10 DF No.2 with 2 row(s) of 10d (0.131"x3") nails spaced 9" o.c.except : starting at 0-1-10 from end at joint G, nail 3 row(s) at 4" o.c. for 2-0-0; starting at 2-5-10 from end at joint G, nail 3 row(s) at 4" o.c. for 3-5-12. 3) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 4) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1 5) This truss has been designed for greater of min roof live load of 15.0 psf or 2.00 times flat roof load of 100.0 psf on overhangs non-concurrent with other live loads. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Bearing at joint(s) J considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 304 lb uplift at joint B. 10) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 11) This truss has been designed for a total drag load of 240 lb. Lumber DOL=(1.33) Plate grip DOL=(1.33) Connect truss to resist drag loads along bottom chord from 20-11-4 to 21-11-4, 0-0-0 to 1-0-0 for 120.0 plf.Continued on page 2 ENGINEERING OF RECORD TO REVIEW AND APPROVE LOADING. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane, Suite 109 Citrus Heights, CA, 95610 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information December 19,2014 Job 03042-14B Truss A1 Truss Type COMMON Qty 5 Ply 1 Lion’s Ridge / Bldg 1/ Roof Job Reference (optional) R43466472 7.600 s Sep 19 2014 MiTek Industries, Inc. Fri Dec 19 15:03:12 2014 Page 2 Alpine Truss, Montrose, CO - 81401 ID:6H?QcMI6c4e8LHnD43dQbjzXm0O-S33YO0lkRm65m1A0CZNF8Fi25H6Y08wdrl?h7xy7L3D NOTES- 12) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) . The design/selection of such connection device(s) is the responsibility of others. 13) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: A-B=-200, B-F=-230, F-H=-230, H-I=-230, B-J=-20 Concentrated Loads (lb) Vert: Q=1800(B) R=-1800(F) Horz: Q=1350(B), R=-1350(F) Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane, Suite 109 Citrus Heights, CA, 95610 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information Job 03042-14B Truss A1G Truss Type GABLE Qty 2 Ply 1 Lion’s Ridge / Bldg 1/ Roof Job Reference (optional) R43466473 7.600 s Sep 23 2014 MiTek Industries, Inc. Fri Dec 19 09:15:26 2014 Page 1 Alpine Truss, Montrose, CO - 81401 ID:6H?QcMI6c4e8LHnD43dQbjzXm0O-ipKAEeM7QYaF3YuizzWli1VMn3cT422LjPSYmNy7Q9F Scale = 1:68.2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1516 31 30 29 28 27 26 25 24 23 22 21 20 19 18 173233 5x5 3x4 5x5 8x8 3x4 3x8 3x8 3x6 21-11-4 21-11-4 15-0-14 15-0-14 21-7-12 6-6-14 21-11-4 0-3-8 0- 1 - 7 11 - 5 - 2 6- 3 - 5 9.00 12 Plate Offsets (X,Y)-- [4:0-4-0,0-4-8], [16:0-2-12,0-0-8], [18:0-3-8,0-1-8], [22:0-2-8,0-3-0] LOADING (psf) TCLL (Roof Snow=100.0) TCDL BCLL BCDL 100.0 15.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 NO IBC2012/TPI2007 CSI. TC BC WB (Matrix) 0.29 0.08 0.71 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a -0.01 (loc) - - 17 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 184 lb FT = 0% GRIP 169/123 LUMBER- TOP CHORD 2x6 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF 1650F 1.5E OTHERS 2x4 WW Stud *Except* ST10: 2x4 SPF 1650F 1.5E BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 11-22, 10-23, 9-24, 12-21, 13-20, 14-19, 15-18 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 21-11-4. (lb) - Max Horz 1=279(LC 26) Max Uplift All uplift 100 lb or less at joint(s) 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 20, 19 except 17=-109(LC 22), 1=-212(LC 19), 18=-110(LC 19) Max Grav All reactions 250 lb or less at joint(s) 30 except 17=901(LC 1), 1=381(LC 42), 22=418(LC 1), 23=312(LC 1), 24=336(LC 1), 25=336(LC 1), 26=333(LC 1), 27=335(LC 1), 28=343(LC 1), 29=332(LC 1), 31=632(LC 1), 21=320(LC 1), 20=638(LC 1), 19=1378(LC 1), 18=2005(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-479/514, 2-3=-411/379, 3-4=-376/374, 4-5=-341/371, 5-6=-310/343, 6-7=-284/320, 7-8=-259/298, 8-9=-235/275, 13-14=-202/331, 14-15=-232/631, 15-16=-791/560, 16-17=-860/108 WEBS 11-22=-392/68, 10-23=-288/33, 9-24=-309/28, 8-25=-309/33, 7-26=-307/29, 6-27=-308/28, 5-28=-318/29, 4-29=-298/31, 2-31=-547/45, 12-21=-291/14, 13-20=-614/25, 14-19=-1341/31, 15-18=-1564/22, 16-18=-512/151 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 20, 19 except (jt=lb) 17=109, 1=212, 18=110. 10) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. Continued on page 2 Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane, Suite 109 Citrus Heights, CA, 95610 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information December 19,2014 Job 03042-14B Truss A1G Truss Type GABLE Qty 2 Ply 1 Lion’s Ridge / Bldg 1/ Roof Job Reference (optional) R43466473 7.600 s Sep 23 2014 MiTek Industries, Inc. Fri Dec 19 09:15:27 2014 Page 2 Alpine Truss, Montrose, CO - 81401 ID:6H?QcMI6c4e8LHnD43dQbjzXm0O-A0uYS_NlBsi6hiTuXh1_FE2XXTyipVIUx3C5Ipy7Q9E NOTES- 11) This truss has been designed for a total drag load of 240 lb. Lumber DOL=(1.33) Plate grip DOL=(1.33) Connect truss to resist drag loads along bottom chord from 20-11-4 to 21-11-4, 0-0-0 to 1-0-0 for 120.0 plf. LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 1-11=-230, 11-13=-230, 1-17=-20 Trapezoidal Loads (plf) Vert: 13=-345-to-16=-2030 Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane, Suite 109 Citrus Heights, CA, 95610 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information Job 03042-14B Truss B1 Truss Type ROOF SPECIAL Qty 25 Ply 1 Lion’s Ridge / Bldg 1/ Roof Job Reference (optional) R43466474 7.600 s Sep 19 2014 MiTek Industries, Inc. Fri Dec 19 14:36:36 2014 Page 1 Alpine Truss, Montrose, CO - 81401 ID:6H?QcMI6c4e8LHnD43dQbjzXm0O-B0dCQHRcIP1ZIm9HiNl_ShcMEwJm3DIjrROD6Sy7LS9 Scale = 1:77.0 A B M C N D E F G H I L K J O P Q R S T 8x12 10x10 10x10 2x4 8x8 5x10 M18SHS 4x4 6x10 4x4 4x8 7-6-6 7-6-6 15-0-14 7-6-8 21-11-4 6-10-6 -3-0-0 3-0-0 7-6-6 7-6-6 15-0-14 7-6-8 18-10-6 3-9-8 21-11-4 3-0-14 22-3-12 0-4-8 1- 1 - 0 9- 6 - 9 12 - 4 - 1 1 8- 6 - 4 9.00 12 4.00 12 Plate Offsets (X,Y)-- [E:0-6-0,0-5-0], [F:0-4-0,Edge], [H:0-2-0,0-1-12], [K:0-3-0,Edge] LOADING (psf) TCLL (Roof Snow=100.0) TCDL BCLL BCDL 100.0 15.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 YES IBC2012/TPI2007 CSI. TC BC WB (Matrix) 0.77 0.59 0.92 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.09 -0.17 0.06 -0.03 (loc) K-L K-L J J-K l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 M18SHS Weight: 180 lb FT = 0% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x6 SPF 1650F 1.5E *Except* E-F: 2x6 SPF 2100F 1.8E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF 1650F 1.5E *Except* E-L,G-K: 2x4 WW Stud OTHERS 2x10 DF No.1&Btr LBR SCAB A-D 2x10 DF No.1&Btr one side SLIDER Left 2x6 SPF 1650F 1.5E 4-9-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-6-15 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt E-K, H-J, G-J MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)J=2804/0-5-8 (min. 0-4-6), B=3364/0-5-8 (min. 0-5-4) Max Horz B=251(LC 34) Max Uplift J=-16(LC 37), B=-147(LC 36) Max Grav J=2804(LC 1), B=3365(LC 15) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD A-B=-0/616, B-M=-3438/130, C-M=-3323/125, C-N=-2771/101, D-N=-2751/100, D-O=-2439/85, E-O=-2320/80, E-P=-1923/124, F-P=-1407/100, F-G=-1471/96, H-J=-610/47 BOT CHORD B-Q=-206/2200, L-Q=-74/2200, L-R=-75/2200, K-R=-75/2200, K-S=-44/737, S-T=-44/737, J-T=-44/737 WEBS E-L=0/298, E-K=-1529/75, F-K=-25/278, G-K=-34/1194, G-J=-2365/59 NOTES- 1) Attached 10-6-15 scab A to D, front face(s) 2x10 DF No.1&Btr with 2 row(s) of 10d (0.131"x3") nails spaced 9" o.c.except : starting at 3-5-11 from end at joint A, nail 3 row(s) at 2" o.c. for 2-0-0; starting at 7-3-12 from end at joint A, nail 2 row(s) at 3" o.c. for 2-11-12. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 3) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 100.0 psf on overhangs non-concurrent with other live loads. 6) All plates are MT20 plates unless otherwise indicated. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) J except (jt=lb) B=147. 10) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 11) This truss has been designed for a total drag load of 240 lb. Lumber DOL=(1.33) Plate grip DOL=(1.33) Connect truss to resist drag loads along bottom chord from 0-0-0 to 1-0-0 for 240.0 plf. LOAD CASE(S) StandardDesign valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane, Suite 109 Citrus Heights, CA, 95610 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information December 19,2014 Job 03042-14B Truss B1AG Truss Type GABLE Qty 1 Ply 1 Lion’s Ridge / Bldg 1/ Roof Job Reference (optional) R43466475 7.600 s Sep 19 2014 MiTek Industries, Inc. Fri Dec 19 14:34:08 2014 Page 1 Alpine Truss, Montrose, CO - 81401 ID:6H?QcMI6c4e8LHnD43dQbjzXm0O-WYhFMhfn9wNYX0rr1I5GSTT3bGoQOGPwpPXOw1y7LUT Scale = 1:85.5 A B AA C AB D E F G H I J K L M N Y X W V U T S R Q P O Z 6x6 6x6 10x10 3x8 M18SHS 8x8 5x8 5x10 3x6 5x5 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 8x8 2x4 6x6 2x4 2x4 2x4 5x12 6x6 18-10-6 18-10-6 21-11-4 3-0-14 -3-0-0 3-0-0 15-0-14 15-0-14 18-10-6 3-9-8 21-11-4 3-0-14 22-3-12 0-4-8 1- 1 - 0 9- 6 - 9 12 - 4 - 1 1 8- 6 - 4 9.00 12 4.00 12 Plate Offsets (X,Y)-- [B:0-5-14,0-0-1], [B:2-5-3,0-2-8], [C:0-1-4,0-2-8], [D:0-4-0,0-4-8], [K:0-3-0,0-3-8], [M:0-2-4,0-4-4], [T:0-2-8,0-3-0] LOADING (psf) TCLL (Roof Snow=100.0) TCDL BCLL BCDL 100.0 15.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 YES IBC2012/TPI2007 CSI. TC BC WB (Matrix) 0.77 0.63 1.00 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in 0.00 0.00 -0.07 -0.00 (loc) N N O M-N l/defl n/r n/r n/a n/r L/d 180 80 n/a 120 PLATES MT20 M18SHS Weight: 229 lb FT = 0% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x6 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF 1650F 1.5E LBR SCAB A-D 2x10 DF No.1 one side SLIDER Left 2x8 SPF 1950F 1.7E 3-9-8 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-3-10 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 3-3-7 oc bracing. WEBS 1 Row at midpt M-O, I-S, H-T, G-U, J-R, K-Q JOINTS 1 Brace at Jt(s): Z MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 21-11-4. (lb) - Max Horz B=250(LC 9) Max Uplift All uplift 100 lb or less at joint(s) U, V, W except O=-2035(LC 35), B=-4462(LC 28), S=-1073(LC 31), T=-243(LC 31), X=-158(LC 37), Y=-667(LC 37), R=-216(LC 39), P=-293(LC 29), Q=-2093(LC 28) Max Grav All reactions 250 lb or less at joint(s) except O=2044(LC 28), B=4487(LC 35), S=1233(LC 48), T=647(LC 61), U=583(LC 15), V=572(LC 15), W=561(LC 15), X=535(LC 48), Y=850(LC 32), R=711(LC 62), P=532(LC 26), Q=2175(LC 35) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD A-B=-0/619, B-AA=-6532/6457, C-AA=-5588/5601, C-AB=-5038/4984, D-AB=-4714/4686, D-E=-4387/4343, E-F=-3752/3661, F-G=-3139/3073, G-H=-2565/2495, H-I=-1797/1792, I-J=-1153/1199, J-K=-674/715, K-L=-605/592, L-M=-592/567, M-O=-1937/1899 BOT CHORD B-Y=-4601/4663, X-Y=-3937/3926, W-X=-3463/3450, V-W=-2983/2970, U-V=-2503/2490, T-U=-2023/2010, S-T=-1543/1530, R-S=-1063/1050, Q-R=-583/570, P-Q=-736/718 WEBS I-S=-1194/1102, H-T=-607/268, G-U=-543/106, F-V=-532/45, E-W=-521/77, D-X=-498/184, C-Y=-784/688, J-R=-673/242, P-Z=-545/340, K-Q=-656/274, Q-Z=-1977/1992, M-Z=-2323/2338, L-Z=-806/694 NOTES- 1) Attached 10-7-2 scab A to D, front face(s) 2x10 DF No.1&Btr with 2 row(s) of 10d (0.131"x3") nails spaced 9" o.c.except : starting at 3-5-13 from end at joint A, nail 3 row(s) at 2" o.c. for 2-0-0. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1 5) Unbalanced snow loads have been considered for this design. 6) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 100.0 psf on overhangs non-concurrent with other live loads. 7) All plates are MT20 plates unless otherwise indicated. 8) Gable requires continuous bottom chord bearing. 9) Gable studs spaced at 2-0-0 oc.Continued on page 2 Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane, Suite 109 Citrus Heights, CA, 95610 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information December 19,2014 Job 03042-14B Truss B1AG Truss Type GABLE Qty 1 Ply 1 Lion’s Ridge / Bldg 1/ Roof Job Reference (optional) R43466475 7.600 s Sep 19 2014 MiTek Industries, Inc. Fri Dec 19 14:34:08 2014 Page 2 Alpine Truss, Montrose, CO - 81401 ID:6H?QcMI6c4e8LHnD43dQbjzXm0O-WYhFMhfn9wNYX0rr1I5GSTT3bGoQOGPwpPXOw1y7LUT NOTES- 10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 12) A plate rating reduction of 20% has been applied for the green lumber members. 13) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) U, V, W except (jt=lb) O=2035, B=4462, S=1073, T=243, X=158, Y=667, R=216, P=293, Q=2093. 14) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 15) This truss has been designed for a total drag load of 240 plf. Lumber DOL=(1.33) Plate grip DOL=(1.33) Connect truss to resist drag loads along bottom chord from 0-0-0 to 21-11-4 for 240.0 plf. LOAD CASE(S) Standard Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane, Suite 109 Citrus Heights, CA, 95610 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information Job 03042-14B Truss B1D Truss Type ROOF SPECIAL Qty 4 Ply 1 Lion’s Ridge / Bldg 1/ Roof Job Reference (optional) R43466476 7.600 s Sep 19 2014 MiTek Industries, Inc. Fri Dec 19 14:36:02 2014 Page 1 Alpine Truss, Montrose, CO - 81401 ID:6H?QcMI6c4e8LHnD43dQbjzXm0O-AUaLHf1IIylNDYZljE8?4WBYpDhh6tki199QvQy7LSh Scale = 1:79.2 A B M C N D E F G H I L K J O P Q R S T U 10x12 M18SHS 12x12 8x8 2x4 7x12 M18SHS 7x12 M18SHS 4x6 8x8 4x6 4x8 7-6-6 7-6-6 15-0-14 7-6-8 21-11-4 6-10-6 -3-0-0 3-0-0 7-6-6 7-6-6 15-0-14 7-6-8 18-10-6 3-9-8 21-11-4 3-0-14 22-3-12 0-4-8 1- 1 - 0 9- 6 - 9 12 - 4 - 1 1 8- 6 - 4 9.00 12 4.00 12 Plate Offsets (X,Y)-- [E:0-6-0,0-5-4], [F:Edge,0-5-8], [H:0-3-0,0-1-12] LOADING (psf) TCLL (Roof Snow=100.0) TCDL BCLL BCDL 100.0 15.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 YES IBC2012/TPI2007 CSI. TC BC WB (Matrix) 0.77 0.66 0.80 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.09 -0.14 0.08 0.06 (loc) K-L J-K J K-L l/defl >999 >592 n/a >999 L/d 360 240 n/a 240 PLATES MT20 M18SHS Weight: 182 lb FT = 0% GRIP 169/123 169/123 LUMBER- TOP CHORD 2x6 SPF 1650F 1.5E *Except* E-F: 2x6 SPF 2100F 1.8E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF 1650F 1.5E *Except* E-L: 2x4 WW Stud OTHERS 2x10 DF No.1&Btr LBR SCAB A-D 2x10 DF No.1&Btr one side SLIDER Left 2x6 SPF 1650F 1.5E 4-9-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-9-3 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 3-10-14 oc bracing. WEBS 1 Row at midpt E-K, F-K, G-K, H-J, G-J MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)K=2791/12-11-12 (min. 0-6-3), J=888/12-11-12 (min. 0-6-3), B=2489/0-5-8 (req. 0-6-11) Max Horz B=269(LC 35) Max Uplift K=-1541(LC 36), J=-2651(LC 31), B=-3010(LC 36) Max Grav K=3656(LC 49), J=2962(LC 26), B=4280(LC 25) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD A-B=-0/616, B-M=-5195/4244, C-M=-4841/3336, C-N=-3881/3332, D-N=-3621/3104, D-O=-3259/2869, E-O=-2548/2167, E-P=-2334/2333, F-P=-1359/1353, F-G=-1106/1125, G-H=-735/806, H-J=-584/73 BOT CHORD B-Q=-3322/3778, L-Q=-3096/3402, L-R=-3096/3402, R-S=-3096/2999, K-S=-2043/2594, K-T=-1792/1788, T-U=-495/382, J-U=-825/912 WEBS E-L=0/298, E-K=-1629/325, F-K=-1443/61, G-K=-1960/1939, G-J=-2799/2793 NOTES- 1) Attached 10-6-15 scab A to D, front face(s) 2x10 DF No.1&Btr with 2 row(s) of 10d (0.131"x3") nails spaced 9" o.c.except : starting at 3-5-11 from end at joint A, nail 3 row(s) at 2" o.c. for 2-0-0; starting at 7-3-12 from end at joint A, nail 2 row(s) at 3" o.c. for 2-11-12. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 3) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 100.0 psf on overhangs non-concurrent with other live loads. 6) All plates are MT20 plates unless otherwise indicated. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9) WARNING: Required bearing size at joint(s) B greater than input bearing size. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) K=1541, J=2651, B=3010. 11) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 12) This truss has been designed for a total drag load of 240 plf. Lumber DOL=(1.33) Plate grip DOL=(1.33) Connect truss to resist drag loads along bottom chord from 8-11-8 to 21-11-4, 0-0-0 to 1-0-0 for 376.6 plf.Continued on page 2 Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane, Suite 109 Citrus Heights, CA, 95610 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information December 19,2014 Job 03042-14B Truss B1D Truss Type ROOF SPECIAL Qty 4 Ply 1 Lion’s Ridge / Bldg 1/ Roof Job Reference (optional) R43466476 7.600 s Sep 19 2014 MiTek Industries, Inc. Fri Dec 19 14:36:02 2014 Page 2 Alpine Truss, Montrose, CO - 81401 ID:6H?QcMI6c4e8LHnD43dQbjzXm0O-AUaLHf1IIylNDYZljE8?4WBYpDhh6tki199QvQy7LSh LOAD CASE(S) Standard Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane, Suite 109 Citrus Heights, CA, 95610 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information Job 03042-14B Truss B1G Truss Type GABLE Qty 1 Ply 1 Lion’s Ridge / Bldg 1/ Roof Job Reference (optional) R43466477 7.600 s Sep 23 2014 MiTek Industries, Inc. Fri Dec 19 09:15:39 2014 Page 1 Alpine Truss, Montrose, CO - 81401 ID:6H?QcMI6c4e8LHnD43dQbjzXm0O-pJc5z5WHMYDP7YNBECFokmXPUJv0dtwFix6kk6y7Q92 Scale = 1:74.9 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 6x6 6x6 6x10 4x6 8x8 5x5 8x8 6x6 21-11-4 21-11-4 15-0-14 15-0-14 18-10-6 3-9-8 21-11-4 3-0-14 22-3-12 0-4-8 0- 1 - 7 8- 7 - 0 11 - 5 - 2 7- 6 - 1 1 9.00 12 4.00 12 Plate Offsets (X,Y)-- [1:0-3-5,Edge], [5:0-4-0,0-4-8], [12:0-3-0,0-2-0], [15:0-2-13,0-4-4], [18:0-2-6,0-4-0], [20:Edge,0-3-8], [25:0-2-8,0-3-0] LOADING (psf) TCLL (Roof Snow=100.0) TCDL BCLL BCDL 100.0 15.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 YES IBC2012/TPI2007 CSI. TC BC WB (Matrix) 0.99 0.68 0.93 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in 0.00 0.00 -0.08 -0.00 (loc) 18-19 18-19 20 18-19 l/defl n/r n/r n/a n/r L/d 180 80 n/a 120 PLATES MT20 Weight: 183 lb FT = 0% GRIP 169/123 LUMBER- TOP CHORD 2x6 SPF 2100F 1.8E *Except* T3,T4: 2x6 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 WW Stud OTHERS 2x4 WW Stud *Except* ST11: 2x4 SPF 1650F 1.5E WEDGE Left: 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-10-10 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 3-1-6 oc bracing. WEBS 1 Row at midpt 18-20, 12-25, 11-26, 10-27, 13-24, 14-23, 18-21 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 21-11-4. (lb) - Max Horz 1=207(LC 35) Max Uplift All uplift 100 lb or less at joint(s) 27, 28, 29, 30, 31, 32, 33, 34, 35, 23 except 1=-3783(LC 32), 20=-1037(LC 31), 25=-1309(LC 31), 26=-435(LC 31), 24=-412(LC 39), 22=-212(LC 38), 21=-992(LC 28) Max Grav All reactions 250 lb or less at joint(s) except 1=3838(LC 31), 20=1063(LC 32), 25=1437(LC 32), 26=623(LC 24), 27=431(LC 15), 28=392(LC 15), 29=341(LC 15), 30=335(LC 1), 31=343(LC 1), 32=333(LC 48), 33=318(LC 15), 34=326(LC 15), 35=373(LC 1), 24=655(LC 26), 23=494(LC 16), 22=538(LC 27), 21=1158(LC 27) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-6370/6327, 2-3=-5957/5897, 3-4=-5543/5479, 4-5=-5164/5137, 5-6=-4751/4728, 6-7=-4329/4276, 7-8=-3920/3873, 8-9=-3521/3520, 9-10=-3098/3108, 10-11=-2667/2683, 11-12=-2028/2044, 12-13=-1583/1632, 13-14=-1401/1484, 14-15=-953/986, 15-16=-644/656, 16-17=-482/497, 17-18=-264/223, 18-20=-1014/990 BOT CHORD 1-35=-5019/5003, 34-35=-4701/4685, 33-34=-4349/4365, 32-33=-4061/4045, 31-32=-3744/3727, 30-31=-3424/3407, 29-30=-3104/3087, 28-29=-2784/2767, 27-28=-2464/2447, 26-27=-2144/2127, 25-26=-1824/1807, 24-25=-1518/1501, 23-24=-1170/1154, 22-23=-850/834, 21-22=-530/514, 20-21=-385/362 WEBS 12-25=-1416/1333, 11-26=-598/449, 10-27=-404/62, 9-28=-365/74, 8-29=-314/43, 7-30=-308/31, 6-31=-316/62, 5-32=-307/98, 4-33=-290/75, 3-34=-304/39, 2-35=-329/60, 13-24=-626/427, 14-23=-468/98, 16-22=-522/235, 17-21=-424/123, 18-21=-1026/1024 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 100.0 psf on overhangs non-concurrent with other live loads.Continued on page 2 Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane, Suite 109 Citrus Heights, CA, 95610 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information December 19,2014 Job 03042-14B Truss B1G Truss Type GABLE Qty 1 Ply 1 Lion’s Ridge / Bldg 1/ Roof Job Reference (optional) R43466477 7.600 s Sep 23 2014 MiTek Industries, Inc. Fri Dec 19 09:15:40 2014 Page 2 Alpine Truss, Montrose, CO - 81401 ID:6H?QcMI6c4e8LHnD43dQbjzXm0O-HWATARXv7sLFkiyOovm1G_4aEjFFMKAOxarHGZy7Q91 NOTES- 6) All plates are 2x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 27, 28, 29, 30, 31, 32, 33, 34, 35, 23 except (jt=lb) 1=3783, 20=1037, 25=1309, 26=435, 24=412, 22=212, 21=992. 12) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 13) This truss has been designed for a total drag load of 240 plf. Lumber DOL=(1.33) Plate grip DOL=(1.33) Connect truss to resist drag loads along bottom chord from 0-0-0 to 21-11-4 for 240.0 plf. LOAD CASE(S) Standard Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane, Suite 109 Citrus Heights, CA, 95610 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information Job 03042-14B Truss B2 Truss Type ROOF SPECIAL Qty 8 Ply 1 Lion’s Ridge / Bldg 1/ Roof Job Reference (optional) R43466478 7.600 s Sep 19 2014 MiTek Industries, Inc. Fri Dec 19 14:35:29 2014 Page 1 Alpine Truss, Montrose, CO - 81401 ID:6H?QcMI6c4e8LHnD43dQbjzXm0O-e74tMNdb4pa3lTYPHp2GEYKvlwS9twwrRWfAGqy7LTC Scale = 1:76.8 A B L C M D E F G H K J I N O P Q R 8x12 10x10 8x8 4x6 2x4 8x8 5x10 M18SHS6x10 4x4 4x4 7-6-6 7-6-6 15-0-14 7-6-8 21-11-4 6-10-6 -3-0-0 3-0-0 7-6-6 7-6-6 15-0-14 7-6-8 18-10-6 3-9-8 21-11-4 3-0-14 1- 1 - 0 9- 6 - 9 12 - 4 - 1 1 8- 6 - 4 9.00 12 4.00 12 Plate Offsets (X,Y)-- [E:0-6-0,0-4-12], [F:0-4-0,Edge], [G:0-5-4,0-3-8], [J:0-3-0,Edge] LOADING (psf) TCLL (Roof Snow=100.0) TCDL BCLL BCDL 100.0 15.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 YES IBC2012/TPI2007 CSI. TC BC WB (Matrix) 0.73 0.58 0.91 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.09 -0.17 0.06 -0.03 (loc) J-K J-K I I-J l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 M18SHS Weight: 177 lb FT = 0% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x6 SPF 1650F 1.5E *Except* E-F: 2x6 SPF 2100F 1.8E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF 1650F 1.5E *Except* E-K,G-J: 2x4 WW Stud OTHERS 2x10 DF No.1&Btr LBR SCAB A-D 2x10 DF No.1&Btr one side SLIDER Left 2x6 SPF 1650F 1.5E 4-9-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-6-11 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt E-J, H-I, G-I MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)I=2681/0-5-8 (min. 0-4-3), B=3375/0-5-8 (min. 0-5-5) Max Horz B=254(LC 29) Max Uplift I=-18(LC 36), B=-147(LC 35) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD A-B=-0/313, B-L=-3427/129, C-L=-3311/124, C-M=-2796/101, D-M=-2727/100, D-E=-2426/84, E-N=-1925/123, F-N=-1408/99, F-G=-1473/95, H-I=-440/48 BOT CHORD B-O=-209/2181, K-O=-78/2181, K-P=-78/2181, J-P=-78/2181, J-Q=-45/740, Q-R=-45/740, I-R=-45/740 WEBS E-K=0/298, E-J=-1509/76, F-J=-24/281, G-J=-37/1175, G-I=-2372/62 NOTES- 1) Attached 10-0-0 scab A to D, front face(s) 2x10 DF No.1&Btr with 2 row(s) of 10d (0.131"x3") nails spaced 9" o.c.except : starting at 3-6-6 from end at joint A, nail 2 row(s) at 4" o.c. for 2-0-0; starting at 7-4-6 from end at joint A, nail 2 row(s) at 7" o.c. for 2-7-10. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 3) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1 4) Unbalanced snow loads have been considered for this design. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) I except (jt=lb) B=147. 9) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 10) This truss has been designed for a total drag load of 240 lb. Lumber DOL=(1.33) Plate grip DOL=(1.33) Connect truss to resist drag loads along bottom chord from 0-0-0 to 1-0-0 for 240.0 plf. LOAD CASE(S) Standard Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane, Suite 109 Citrus Heights, CA, 95610 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information December 19,2014 Job 03042-14B Truss BXGD Truss Type FLAT GIRDER Qty 2 Ply 3 Lion’s Ridge / Bldg 1/ Roof Job Reference (optional) R43466479 7.600 s Sep 23 2014 MiTek Industries, Inc. Fri Dec 19 09:15:43 2014 Page 1 Alpine Truss, Montrose, CO - 81401 ID:6H?QcMI6c4e8LHnD43dQbjzXm0O-i5sbpSZoQnjqbAhzT2JkuciCSwKDZnSrdY4xtuy7Q9_ Scale = 1:51.5 1 2 3 4 5 10 9 8 7 6 3x6 8x8 3x6 7x14 2x4 5x8 4x10 2x4 12x12 8x8 1-6-12 1-6-12 3-6-12 2-0-0 5-6-12 2-0-0 8-0-8 2-5-12 1-6-12 1-6-12 3-6-12 2-0-0 5-6-12 2-0-0 8-0-8 2-5-12 8- 5 - 0 Plate Offsets (X,Y)-- [1:Edge,0-2-12], [5:0-3-8,Edge], [7:0-6-0,0-6-4], [8:0-6-4,0-2-0] LOADING (psf) TCLL (Roof Snow=100.0) TCDL BCLL BCDL 100.0 15.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 NO IBC2012/TPI2007 CSI. TC BC WB (Matrix) 0.55 0.47 0.57 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.10 -0.12 0.00 0.00 (loc) 8 8 6 9 l/defl >978 >749 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 319 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x8 SPF 1950F 1.7E WEBS 2x4 SPF 1650F 1.5E BRACING- TOP CHORD 2-0-0 oc purlins (6-0-0 max.): 1-5, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 1-10, 5-6 REACTIONS.(lb/size)10=11530/0-3-8 (req. 0-6-0), 6=15591/0-3-8 (req. 0-8-2) Max Horz 10=-179(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-10=-9320/0, 1-2=-1611/0, 2-3=-1611/0, 3-4=-2493/0, 4-5=-2493/0, 5-6=-8793/0 BOT CHORD 8-9=0/2829, 7-8=0/2829 WEBS 1-9=0/9205, 2-9=-275/49, 3-9=-5004/0, 3-8=0/5632, 3-7=-1381/9, 4-7=-465/28, 5-7=0/8872 NOTES- 1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x8 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-5-0 oc, Except member 2-9 2x4 - 1 row at 0-6-0 oc, member 9-3 2x4 - 1 row at 0-9-0 oc, member 3-8 2x4 - 2 rows staggered at 0-7-0 oc, member 7-3 2x4 - 1 row at 0-9-0 oc, member 4-7 2x4 - 2 rows staggered at 0-7-0 oc, member 7-5 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 4) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) WARNING: Required bearing size at joint(s) 10, 6 greater than input bearing size. 9) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 3584 lb down at 1-6-12, 2712 lb down at 1-6-12, 3584 lb down at 3-6-12, 2712 lb down at 3-6-12, 3584 lb down at 5-6-12, 2712 lb down at 5-6-12, and 3584 lb down at 7-10-12, and 2712 lb down at 7-10-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard Continued on page 2 Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane, Suite 109 Citrus Heights, CA, 95610 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information December 19,2014 Job 03042-14B Truss BXGD Truss Type FLAT GIRDER Qty 2 Ply 3 Lion’s Ridge / Bldg 1/ Roof Job Reference (optional) R43466479 7.600 s Sep 23 2014 MiTek Industries, Inc. Fri Dec 19 09:15:43 2014 Page 2 Alpine Truss, Montrose, CO - 81401 ID:6H?QcMI6c4e8LHnD43dQbjzXm0O-i5sbpSZoQnjqbAhzT2JkuciCSwKDZnSrdY4xtuy7Q9_ LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 1-5=-230, 6-10=-20 Concentrated Loads (lb) Vert: 6=-6296(F=-3584, B=-2712) 9=-6296(F=-3584, B=-2712) 8=-6296(F=-3584, B=-2712) 7=-6296(F=-3584, B=-2712) Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane, Suite 109 Citrus Heights, CA, 95610 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information Job 03042-14B Truss C1 Truss Type ROOF SPECIAL Qty 36 Ply 1 Lion’s Ridge / Bldg 1/ Roof Job Reference (optional) R43466480 7.600 s Sep 23 2014 MiTek Industries, Inc. Fri Dec 19 09:15:46 2014 Page 1 Alpine Truss, Montrose, CO - 81401 ID:6H?QcMI6c4e8LHnD43dQbjzXm0O-6gXkRUcgji6PSdQY8AtRWFKff7Gum6dHJWIbSCy7Q8x Scale = 1:83.7 1 2 3 4 5 6 7 8 9 10 15 14 13 12 11 16 17 18 19 20 21 9x10 M18SHS 6x8 6x8 6x10 5x12 6x8 5x10 4x4 5x8 5x5 3x8 M18SHS 8x8 6x10 8-8-4 8-8-4 16-11-4 8-3-0 26-4-6 9-5-2 30-1-14 3-9-8 33-2-12 3-0-14 -2-0-0 2-0-0 8-8-4 8-8-4 12-10-10 4-2-6 16-11-4 4-0-10 21-7-13 4-8-9 26-4-6 4-8-9 30-1-14 3-9-8 33-2-12 3-0-14 33-7-4 0-4-8 1- 1 - 0 5- 3 - 1 3 9- 6 - 9 12 - 4 - 1 1 8- 6 - 4 3.00 12 9.00 12 4.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [3:0-2-8,Edge], [5:0-4-0,0-1-0], [6:0-1-0,0-1-8], [7:0-4-4,0-2-12], [8:0-8-0,0-3-0], [9:0-2-6,0-4-0], [11:0-3-8,Edge], [12:0-2-4,0-1-8], [14:0-3-12 ,0-3-4], [15:0-3-8,0-3-0] LOADING (psf) TCLL (Roof Snow=100.0) TCDL BCLL BCDL 100.0 15.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 YES IBC2012/TPI2007 CSI. TC BC WB (Matrix) 0.80 0.80 0.67 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.31 -0.54 0.04 0.02 (loc) 13-14 13-14 11 13-14 l/defl >933 >538 n/a >999 L/d 360 240 n/a 240 PLATES MT20 M18SHS Weight: 226 lb FT = 0% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x6 SPF 2100F 1.8E *Except* T4,T5: 2x6 SPF 1650F 1.5E, T1: 2x10 DF No.2 BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF 1650F 1.5E WEDGE Left: 2x4 WW Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-10-1 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 5-8-3 oc bracing: 2-15. WEBS 1 Row at midpt 6-13, 8-12, 9-11, 4-15 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)2=1008/0-5-8 (min. 0-1-15), 15=4916/0-5-8 (req. 0-7-11), 11=2943/0-5-8 (min. 0-4-15) Max Horz 2=234(LC 34) Max Uplift2=-112(LC 28), 15=-13(LC 36) Max Grav 2=1224(LC 14), 15=4916(LC 1), 11=3129(LC 16) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-16=-175/1542, 3-16=-107/1865, 3-4=-71/1684, 4-5=-2920/38, 5-6=-3618/51, 6-17=-1894/80, 7-17=-1728/75, 7-8=-1657/82, 8-9=-1003/55, 9-11=-3062/21 BOT CHORD 2-18=-1464/48, 15-18=-1464/13, 15-19=-57/1565, 14-19=-92/1565, 14-20=-24/1992, 20-21=-24/1992, 13-21=-24/1992, 12-13=-23/787 WEBS 3-15=-2141/69, 4-14=0/1875, 5-14=-2301/79, 6-13=-1779/74, 7-13=-44/758, 8-13=-9/1131, 8-12=-2142/26, 9-12=0/2284, 6-14=0/1542, 4-15=-4250/66 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 100.0 psf on overhangs non-concurrent with other live loads. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) WARNING: Required bearing size at joint(s) 15 greater than input bearing size. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 15 except (jt=lb) 2=112. 10) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 11) This truss has been designed for a total drag load of 240 lb. Lumber DOL=(1.33) Plate grip DOL=(1.33) Connect truss to resist drag loads along bottom chord from 8-2-4 to 9-2-4 for 240.0 plf. LOAD CASE(S) Standard Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane, Suite 109 Citrus Heights, CA, 95610 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information December 19,2014 Job 03042-14B Truss C1G Truss Type GABLE Qty 8 Ply 1 Lion’s Ridge / Bldg 1/ Roof Job Reference (optional) R43466481 7.600 s Sep 23 2014 MiTek Industries, Inc. Fri Dec 19 09:15:49 2014 Page 1 Alpine Truss, Montrose, CO - 81401 ID:6H?QcMI6c4e8LHnD43dQbjzXm0O-WFDs3WeZ?dU_K586qIQ88ty9kLJkzSSj?UXG3Xy7Q8u Scale = 1:84.4 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 36 37 38 39 404x6 6x10 7x12 M18SHS 6x10 4x4 6x8 7x12 M18SHS 5x12 8x12 4x8 5x8 5x5 3x8 M18SHS 8x8 4x6 8x12 8-8-4 8-8-4 16-11-4 8-3-0 21-8-13 4-9-9 26-4-6 4-7-9 30-1-14 3-9-8 33-2-12 3-0-14 8-8-4 8-8-4 12-10-10 4-2-6 16-11-4 4-0-10 21-8-13 4-9-9 26-4-6 4-7-9 30-1-14 3-9-8 33-2-12 3-0-14 33-7-4 0-4-8 0- 3 - 8 9- 6 - 9 12 - 4 - 1 1 8- 6 - 4 3.00 12 9.00 12 4.00 12 Plate Offsets (X,Y)-- [1:0-5-0,Edge], [3:0-6-0,0-1-15], [4:0-10-4,0-4-4], [6:0-2-13,0-1-8], [8:0-7-12,0-3-0], [9:0-2-6,0-4-0], [11:0-3-8,Edge], [12:0-2-4,0-1-8], [16:0-3-8,0-3-0] LOADING (psf) TCLL (Roof Snow=100.0) TCDL BCLL BCDL 100.0 15.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 YES IBC2012/TPI2007 CSI. TC BC WB (Matrix) 0.81 0.72 0.73 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.21 -0.30 0.05 0.02 (loc) 14-15 14-15 11 14-15 l/defl >999 >981 n/a >999 L/d 360 240 n/a 240 PLATES MT20 M18SHS Weight: 235 lb FT = 0% GRIP 118/123 113/123 LUMBER- TOP CHORD 2x6 SPF 1650F 1.5E *Except* T1: 1.5X5.5 Microllam LVL 2.0E TG, T2: 2x6 SPF 2100F 1.8E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF 1650F 1.5E *Except* W4: 1.5X5.5 Microllam LVL 2.0E TG, W6,W5: 2x4 WW Stud OTHERS 2x4 WW Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-0-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 5-0-15 oc bracing: 1-16. WEBS 1 Row at midpt 6-13, 8-12, 9-11, 3-16, 4-6, 4-14 REACTIONS.(lb/size)1=466/0-5-8 (min. 0-1-8), 16=4902/0-5-8 (req. 0-7-11), 11=2966/0-5-8 (min. 0-4-14) Max Horz 1=232(LC 34) Max Uplift1=-45(LC 28), 16=-8(LC 36) Max Grav 1=597(LC 64), 16=4902(LC 1), 11=3107(LC 16) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-36=-153/1528, 2-36=-88/1804, 2-3=-80/1529, 3-4=-3681/35, 5-6=-1883/50, 6-37=-1843/86, 7-37=-1764/85, 7-8=-1609/88, 8-9=-1000/54, 4-15=-1042/75, 4-5=-1591/59, 9-11=-3050/18 BOT CHORD 1-38=-1483/37, 16-38=-1483/28, 16-39=-45/2048, 15-39=-60/2048, 14-15=0/3358, 14-40=-22/1971, 13-40=-22/1971, 12-13=-22/797 WEBS 2-16=-2411/72, 3-15=0/1963, 6-13=-1785/54, 7-13=-51/715, 8-13=-24/1125, 8-12=-2129/44, 9-12=0/2311, 6-14=0/1293, 3-16=-4405/69, 4-6=-1295/57, 4-14=-1842/21 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 100.0 psf on overhangs non-concurrent with other live loads. 6) All plates are MT20 plates unless otherwise indicated. 7) All plates are 2x4 MT20 unless otherwise indicated. 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 11) WARNING: Required bearing size at joint(s) 16 greater than input bearing size. 12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 16. 13) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. Continued on page 2 Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane, Suite 109 Citrus Heights, CA, 95610 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information December 19,2014 Job 03042-14B Truss C1G Truss Type GABLE Qty 8 Ply 1 Lion’s Ridge / Bldg 1/ Roof Job Reference (optional) R43466481 7.600 s Sep 23 2014 MiTek Industries, Inc. Fri Dec 19 09:15:49 2014 Page 2 Alpine Truss, Montrose, CO - 81401 ID:6H?QcMI6c4e8LHnD43dQbjzXm0O-WFDs3WeZ?dU_K586qIQ88ty9kLJkzSSj?UXG3Xy7Q8u NOTES- 14) This truss has been designed for a total drag load of 240 lb. Lumber DOL=(1.33) Plate grip DOL=(1.33) Connect truss to resist drag loads along bottom chord from 8-2-4 to 9-2-4 for 240.0 plf. 15) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane, Suite 109 Citrus Heights, CA, 95610 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information Job 03042-14B Truss D1 Truss Type Monopitch Qty 35 Ply 1 Lion’s Ridge / Bldg 1/ Roof Job Reference (optional) R43466482 7.600 s Sep 23 2014 MiTek Industries, Inc. Fri Dec 19 09:15:50 2014 Page 1 Alpine Truss, Montrose, CO - 81401 ID:6H?QcMI6c4e8LHnD43dQbjzXm0O-?RnFHrfBmwcrxEjJN0xNg5UIZlcYitatE8Hpc_y7Q8t Scale = 1:49.5 1 2 3 4 5 6 7 8 13 12 11 10 9 14 15 8x8 4x4 5x10 M18SHS7x10 7x14 5x5 2x4 5x10 M18SHS 4x6 4x6 4x6 5x5 4-3-9 4-3-9 8-3-7 3-11-14 13-8-2 5-4-11 17-4-8 3-8-6 21-11-4 4-6-12 -3-0-0 3-0-0 4-3-9 4-3-9 8-3-7 3-11-14 13-8-2 5-4-11 17-4-8 3-8-6 21-11-4 4-6-12 1- 1 - 0 8- 4 - 1 2 4.00 12 Plate Offsets (X,Y)-- [2:0-1-4,Edge], [5:0-2-0,0-3-0], [7:0-2-0,0-1-12], [10:0-2-8,0-1-8], [12:0-5-0,0-3-0] LOADING (psf) TCLL (Roof Snow=100.0) TCDL BCLL BCDL 100.0 15.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 YES IBC2012/TPI2007 CSI. TC BC WB (Matrix) 0.94 0.94 0.87 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.21 -0.29 0.12 0.02 (loc) 11-12 11-12 9 12 l/defl >999 >878 n/a >999 L/d 360 240 n/a 240 PLATES MT20 M18SHS Weight: 147 lb FT = 0% GRIP 169/123 169/123 LUMBER- TOP CHORD 2x6 SPF 2100F 1.8E *Except* T1: 2x10 DF No.2 BOT CHORD 2x4 SPF 1650F 1.5E *Except* B1: 2x4 SPF 2100F 1.8E WEBS 2x4 SPF 1650F 1.5E *Except* W1,W2,W3,W5: 2x4 WW Stud SLIDER Left 2x4 WW Stud 2-1-14 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 8-9, 6-10, 7-9 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)9=2635/0-5-8 (min. 0-5-8), 2=3526/0-5-8 (min. 0-4-15) Max Horz 2=255(LC 31) Max Uplift2=-120(LC 28) Max Grav 9=3523(LC 15), 2=3910(LC 15) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-5122/100, 3-4=-4745/129, 4-5=-5236/101, 5-14=-3860/102, 6-14=-3572/80, 6-7=-2257/88, 7-8=-281/131, 8-9=-620/23 BOT CHORD 2-15=-285/4119, 13-15=-285/4119, 12-13=-285/4119, 11-12=0/4943, 10-11=0/3374, 9-10=-6/1957 WEBS 4-12=-49/934, 5-12=-302/156, 5-11=-1831/20, 6-11=0/1042, 6-10=-2462/11, 7-10=0/2073, 7-9=-3440/0 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 100.0 psf on overhangs non-concurrent with other live loads. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=120. 9) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 10) This truss has been designed for a total drag load of 240 lb. Lumber DOL=(1.33) Plate grip DOL=(1.33) Connect truss to resist drag loads along bottom chord from 0-0-0 to 1-0-0 for 240.0 plf. LOAD CASE(S) Standard Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane, Suite 109 Citrus Heights, CA, 95610 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information December 19,2014 Job 03042-14B Truss D1D Truss Type GABLE Qty 5 Ply 1 Lion’s Ridge / Bldg 1/ Roof Job Reference (optional) R43466483 7.600 s Sep 23 2014 MiTek Industries, Inc. Fri Dec 19 09:15:53 2014 Page 1 Alpine Truss, Montrose, CO - 81401 ID:6H?QcMI6c4e8LHnD43dQbjzXm0O-P0SNvth33r_PoiSu38V4Ij6riyhQvD2Jw6VTCIy7Q8q Scale: 1/4"=1’ 1 2 3 4 5 6 7 8 9 10 11 12 13 24 23 22 21 20 19 18 17 16 15 14 25 8x8 4x4 6x6 12x12 3x6 5x5 2x4 2x4 2x4 2x4 5x5 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x6 3x10 21-11-4 21-11-4 -3-0-0 3-0-0 21-11-4 21-11-4 1- 1 - 0 8- 4 - 1 2 4.00 12 Plate Offsets (X,Y)-- [2:Edge,0-3-8], [3:0-7-9,0-0-12], [4:0-4-0,0-3-8], [18:0-2-8,0-3-0] LOADING (psf) TCLL (Roof Snow=100.0) TCDL BCLL BCDL 100.0 15.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 YES IBC2012/TPI2007 CSI. TC BC WB (Matrix) 0.82 0.68 0.95 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.02 -0.08 (loc) 1 1 15 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 149 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x6 SPF 1650F 1.5E *Except* T1: 2x10 DF No.2 BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF 1650F 1.5E WEDGE Left: 2x4 SPF 1650F 1.5E BRACING- TOP CHORD Structural wood sheathing directly applied or 4-2-3 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 3-2-0 oc bracing. WEBS 1 Row at midpt 13-14 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 21-11-4. (lb) - Max Horz 2=204(LC 30) Max Uplift All uplift 100 lb or less at joint(s) 17, 18, 19, 21, 22 except 14=-1325(LC 31), 2=-2888(LC 28), 15=-1257(LC 28), 16=-187(LC 30), 23=-285(LC 29), 24=-1354(LC 14) Max Grav All reactions 250 lb or less at joint(s) except 14=1395(LC 24), 2=3429(LC 25), 15=1363(LC 35), 16=671(LC 25), 17=705(LC 15), 18=693(LC 15), 19=700(LC 15), 20=681(LC 15), 21=529(LC 15), 22=519(LC 1), 23=674(LC 22), 24=751(LC 28) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-5784/5569, 3-4=-4906/4750, 4-5=-4340/4197, 5-6=-3771/3638, 6-25=-3239/3122, 7-25=-3031/2887, 7-8=-2740/2617, 8-9=-2233/2117, 9-10=-1688/1604, 10-11=-1139/1076, 11-12=-746/688, 12-13=-504/467, 13-14=-253/125 BOT CHORD 2-24=-4901/4902, 23-24=-4458/4389, 22-23=-4003/3982, 21-22=-3523/3502, 20-21=-3043/3022, 19-20=-2563/2542, 18-19=-2083/2062, 17-18=-1594/1572, 16-17=-1124/1102, 15-16=-644/622, 14-15=-422/400 WEBS 12-15=-1277/1255, 11-16=-636/227, 10-17=-666/71, 9-18=-653/40, 8-19=-659/36, 7-20=-642/25, 6-21=-488/56, 5-22=-483/58, 4-23=-629/314, 3-24=-701/1283, 12-14=-1433/1435 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 100.0 psf on overhangs non-concurrent with other live loads. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 2-0-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.Continued on page 2 Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane, Suite 109 Citrus Heights, CA, 95610 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information December 19,2014 Job 03042-14B Truss D1D Truss Type GABLE Qty 5 Ply 1 Lion’s Ridge / Bldg 1/ Roof Job Reference (optional) R43466483 7.600 s Sep 23 2014 MiTek Industries, Inc. Fri Dec 19 09:15:53 2014 Page 2 Alpine Truss, Montrose, CO - 81401 ID:6H?QcMI6c4e8LHnD43dQbjzXm0O-P0SNvth33r_PoiSu38V4Ij6riyhQvD2Jw6VTCIy7Q8q NOTES- 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 17, 18, 19, 21, 22 except (jt=lb) 14=1325, 2=2888, 15=1257, 16=187, 23=285, 24=1354. 11) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 12) This truss has been designed for a total drag load of 240 plf. Lumber DOL=(1.33) Plate grip DOL=(1.33) Connect truss to resist drag loads along bottom chord from 0-0-0 to 21-11-4 for 240.0 plf. 13) This truss has large uplift reaction(s) from gravity load case(s). Proper connection is required to secure truss against upward movement at the bearings. Building designer must provide for uplift reactions indicated. LOAD CASE(S) Standard Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane, Suite 109 Citrus Heights, CA, 95610 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information Job 03042-14B Truss D1G Truss Type GABLE Qty 2 Ply 1 Lion’s Ridge / Bldg 1/ Roof Job Reference (optional) R43466484 7.600 s Sep 23 2014 MiTek Industries, Inc. Fri Dec 19 09:15:56 2014 Page 1 Alpine Truss, Montrose, CO - 81401 ID:6H?QcMI6c4e8LHnD43dQbjzXm0O-pb8WXvjyMmM_f9BTkH2nwMkS29jH6cblc4k7pdy7Q8n Scale = 1:45.3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 29 28 27 26 25 24 23 22 21 20 19 18 17 165x10 4x4 5x5 3x6 6x6 8x8 5x5 21-11-4 21-11-4 21-11-4 21-11-4 0- 3 - 4 7- 7 - 0 4.00 12 Plate Offsets (X,Y)-- [1:0-3-15,Edge], [10:0-4-0,0-4-8], [14:0-3-0,0-4-0], [16:0-2-4,0-3-0], [22:0-2-8,0-3-0] LOADING (psf) TCLL (Roof Snow=100.0) TCDL BCLL BCDL 100.0 15.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 YES IBC2012/TPI2007 CSI. TC BC WB (Matrix) 0.43 0.66 0.71 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a -0.08 (loc) - - 17 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 137 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x6 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF 1650F 1.5E BRACING- TOP CHORD Structural wood sheathing directly applied or 3-10-13 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 3-1-11 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 21-11-4. (lb) - Max Horz 1=178(LC 30) Max Uplift All uplift 100 lb or less at joint(s) 19, 20, 21, 22, 23, 24, 25, 26, 28 except 1=-1602(LC 27), 16=-1178(LC 30), 17=-993(LC 27), 18=-298(LC 29) Max Grav All reactions 250 lb or less at joint(s) except 1=1747(LC 34), 16=1184(LC 43), 17=1075(LC 34), 18=553(LC 24), 19=463(LC 14), 20=453(LC 14), 21=453(LC 14), 22=457(LC 14), 23=457(LC 14), 24=453(LC 14), 25=396(LC 14), 26=334(LC 1), 27=369(LC 1), 29=1128(LC 14) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-5319/5078, 2-3=-4225/4086, 3-4=-3845/3724, 4-5=-3532/3419, 5-6=-3192/3082, 6-7=-2851/2744, 7-8=-2509/2401, 8-9=-2179/2079, 9-10=-1820/1726, 10-11=-1490/1409, 11-12=-1142/1075, 12-13=-757/704, 13-14=-548/506, 14-15=-291/265 BOT CHORD 1-29=-4975/4956, 28-29=-3954/3935, 27-28=-3602/3583, 26-27=-3314/3295, 25-26=-2994/2975, 24-25=-2674/2655, 23-24=-2354/2335, 22-23=-2034/2015, 21-22=-1705/1686, 20-21=-1395/1376, 19-20=-1075/1056, 18-19=-755/736, 17-18=-435/416, 16-17=-299/280 WEBS 14-17=-939/925, 13-18=-538/319, 12-19=-436/50, 11-20=-426/59, 10-21=-427/66, 9-22=-430/75, 8-23=-429/48, 7-24=-427/20, 6-25=-367/17, 5-26=-313/16, 4-27=-324/16, 2-29=-989/42, 14-16=-1300/1307 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1 4) Unbalanced snow loads have been considered for this design. 5) All plates are 2x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. Continued on page 2 Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane, Suite 109 Citrus Heights, CA, 95610 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information December 19,2014 Job 03042-14B Truss D1G Truss Type GABLE Qty 2 Ply 1 Lion’s Ridge / Bldg 1/ Roof Job Reference (optional) R43466484 7.600 s Sep 23 2014 MiTek Industries, Inc. Fri Dec 19 09:15:56 2014 Page 2 Alpine Truss, Montrose, CO - 81401 ID:6H?QcMI6c4e8LHnD43dQbjzXm0O-pb8WXvjyMmM_f9BTkH2nwMkS29jH6cblc4k7pdy7Q8n NOTES- 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 19, 20, 21, 22, 23, 24, 25, 26, 28 except (jt=lb) 1=1602, 16=1178, 17=993, 18=298. 11) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 12) This truss has been designed for a total drag load of 240 plf. Lumber DOL=(1.33) Plate grip DOL=(1.33) Connect truss to resist drag loads along bottom chord from 0-0-0 to 21-11-4 for 240.0 plf. LOAD CASE(S) Standard Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane, Suite 109 Citrus Heights, CA, 95610 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information Job 03042-14B Truss E1 Truss Type Roof Special Qty 25 Ply 1 Lion’s Ridge / Bldg 1/ Roof Job Reference (optional) R43466485 7.600 s Sep 23 2014 MiTek Industries, Inc. Fri Dec 19 09:15:58 2014 Page 1 Alpine Truss, Montrose, CO - 81401 ID:6H?QcMI6c4e8LHnD43dQbjzXm0O-mzGGyalCuOcivTKrrh5F?nqmfzLLaUl24ODEuWy7Q8l Scale = 1:49.2 1 2 3 4 5 6 10 9 8 7111213 4x4 5x10 M18SHS7x12 M18SHS 8x12 2x4 4x8 5x5 8x10 7x12 M18SHS 5x10 M18SHS 4-10-13 4-10-13 10-0-15 5-2-3 14-8-9 4-7-10 19-10-7 5-1-14 24-9-4 4-10-13 4-10-13 4-10-13 10-0-15 5-2-3 14-8-9 4-7-10 19-10-7 5-1-14 24-9-4 4-10-13 1- 9 - 8 6- 9 - 2 8- 4 - 1 2 3.00 12 4.00 12 Plate Offsets (X,Y)-- [2:0-6-0,0-4-8], [5:0-8-0,0-4-12], [8:0-2-0,0-1-12] LOADING (psf) TCLL (Roof Snow=100.0) TCDL BCLL BCDL 100.0 15.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 YES IBC2012/TPI2007 CSI. TC BC WB (Matrix) 0.55 0.88 0.85 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.33 -0.60 0.15 0.02 (loc) 8-9 8-9 7 9 l/defl >888 >489 n/a >999 L/d 360 240 n/a 240 PLATES MT20 M18SHS Weight: 131 lb FT = 0% GRIP 169/123 169/123 LUMBER- TOP CHORD 2x6 SPF 2100F 1.8E *Except* T3: 2x6 SPF 1650F 1.5E BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x4 SPF 1650F 1.5E *Except* W3,W4: 2x4 WW Stud, W1: 2x6 SPF 1650F 1.5E BRACING- TOP CHORD Structural wood sheathing directly applied or 3-1-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-7, 4-8, 5-7, 2-10 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)7=3049/0-5-8 (min. 0-4-11), 10=3049/0-5-8 (min. 0-4-11) Max Horz 10=242(LC 31) Max Uplift10=-29(LC 28) Max Grav 7=3673(LC 14), 10=3678(LC 14) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-802/0, 2-3=-6380/55, 3-4=-6415/31, 4-5=-2630/75, 5-6=-264/90, 6-7=-438/22, 1-10=-790/9 BOT CHORD 10-11=-73/5555, 9-11=-98/5555, 9-12=0/4603, 12-13=0/4603, 8-13=0/4603, 7-8=0/2420 WEBS 2-9=0/514, 3-9=-1605/52, 4-9=0/2127, 4-8=-3100/52, 5-8=0/2310, 5-7=-4022/0, 2-10=-5657/156 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10. 8) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 9) This truss has been designed for a total drag load of 240 lb. Lumber DOL=(1.33) Plate grip DOL=(1.33) Connect truss to resist drag loads along bottom chord from 0-0-0 to 1-0-0 for 240.0 plf. LOAD CASE(S) Standard Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane, Suite 109 Citrus Heights, CA, 95610 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information December 19,2014 Job 03042-14B Truss E2 Truss Type Roof Special Qty 8 Ply 1 Lion’s Ridge / Bldg 1/ Roof Job Reference (optional) R43466486 7.600 s Sep 23 2014 MiTek Industries, Inc. Fri Dec 19 09:15:59 2014 Page 1 Alpine Truss, Montrose, CO - 81401 ID:6H?QcMI6c4e8LHnD43dQbjzXm0O-EApeAwmqfhkZWdv1PPcUY_MxENj1JwrBI2ynQyy7Q8k Scale: 1/4"=1’ 1 2 3 4 5 9 8 7 61011 7x12 M18SHS 7x10 4x6 5x10 M18SHS3x4 3x10 5x10 M18SHS 4x8 5x10 M18SHS 8-6-7 8-6-7 15-1-13 6-7-6 21-11-4 6-9-7 5-0-1 5-0-1 8-6-7 3-6-6 15-1-13 6-7-6 21-11-4 6-9-7 1- 9 - 8 3- 1 1 - 2 8- 4 - 1 2 3.00 12 4.00 12 Plate Offsets (X,Y)-- [3:0-8-4,0-4-0], [7:0-5-0,0-3-0] LOADING (psf) TCLL (Roof Snow=100.0) TCDL BCLL BCDL 100.0 15.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 YES IBC2012/TPI2007 CSI. TC BC WB (Matrix) 0.56 0.73 0.93 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.21 -0.28 0.11 -0.02 (loc) 7-8 7-8 6 6-7 l/defl >999 >920 n/a >999 L/d 360 240 n/a 240 PLATES MT20 M18SHS Weight: 113 lb FT = 0% GRIP 169/123 169/123 LUMBER- TOP CHORD 2x6 SPF 2100F 1.8E BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x4 SPF 1650F 1.5E *Except* W3,W4,W6: 2x4 WW Stud, W1: 2x6 SPF 1650F 1.5E BRACING- TOP CHORD Structural wood sheathing directly applied or 4-3-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-6, 3-7, 4-6, 2-9 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)6=2695/0-5-8 (min. 0-3-9), 9=2695/0-5-8 (min. 0-4-1) Max Horz 9=244(LC 34) Max Uplift9=-41(LC 27) Max Grav 6=2821(LC 14), 9=3222(LC 14) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-901/7, 2-3=-4757/84, 3-4=-2844/106, 4-5=-370/116, 5-6=-618/26, 1-9=-1019/14 BOT CHORD 9-10=-95/4328, 8-10=-96/4328, 7-8=0/4503, 7-11=0/2497, 6-11=0/2497 WEBS 2-8=-12/411, 3-7=-2276/27, 4-7=0/1204, 4-6=-3258/15, 2-9=-4214/159 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9. 8) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 9) This truss has been designed for a total drag load of 240 lb. Lumber DOL=(1.33) Plate grip DOL=(1.33) Connect truss to resist drag loads along bottom chord from 0-0-0 to 1-0-0 for 240.0 plf. LOAD CASE(S) Standard Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane, Suite 109 Citrus Heights, CA, 95610 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information December 19,2014 Job 03042-14B Truss E2G Truss Type Roof Special Qty 1 Ply 1 Lion’s Ridge / Bldg 1/ Roof Job Reference (optional) R43466487 7.600 s Sep 23 2014 MiTek Industries, Inc. Fri Dec 19 09:16:01 2014 Page 1 Alpine Truss, Montrose, CO - 81401 ID:6H?QcMI6c4e8LHnD43dQbjzXm0O-AYxPbcn4BJ?Hmx3QXqeydPSHxAQ6nrFUmMRuUry7Q8i Scale = 1:47.4 1 2 3 4 5 6 7 11 10 9 81213 10x10 5x5 5x6 5x10 M18SHS3x4 5x6 8x8 6x8 4x6 4x10 8-6-7 8-6-7 15-1-13 6-7-6 21-11-4 6-9-7 5-1-3 5-1-3 8-6-7 3-5-4 15-1-13 6-7-6 21-11-4 6-9-7 1- 3 - 7 3- 1 1 - 2 1- 5 - 1 1 7- 1 0 - 1 5 3.00 12 4.00 12 Plate Offsets (X,Y)-- [1:Edge,0-5-2], [5:0-4-0,0-4-12], [9:0-4-0,0-3-4] LOADING (psf) TCLL (Roof Snow=100.0) TCDL BCLL BCDL 100.0 15.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 YES IBC2012/TPI2007 CSI. TC BC WB (Matrix) 0.54 0.69 0.87 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.19 -0.26 0.11 -0.02 (loc) 9-10 10-11 8 8-9 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 M18SHS Weight: 120 lb FT = 0% GRIP 118/123 197/144 LUMBER- TOP CHORD 2x6 SPF 2100F 1.8E *Except* T1: 2x6 SPF 1650F 1.5E BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x4 SPF 1650F 1.5E *Except* W3,W4,W6: 2x4 WW Stud, W1: 1.5X7.25 Microllam LVL 2.0E TG BRACING- TOP CHORD Structural wood sheathing directly applied or 4-6-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-8, 5-9, 6-8 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)8=2686/0-5-8 (min. 0-3-7), 11=2686/0-5-8 (min. 0-3-11) Max Horz 11=262(LC 30) Max Uplift11=-39(LC 27) Max Grav 8=2706(LC 14), 11=2923(LC 14) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-88/502, 2-3=-2489/50, 2-4=-1963/0, 4-5=-4314/80, 5-6=-2694/107, 6-7=-369/117, 7-8=-621/26, 3-11=-1628/32, 1-3=-607/19 BOT CHORD 11-12=-82/4252, 10-12=-59/4252, 9-10=0/4037, 9-13=0/2360, 8-13=0/2360 WEBS 4-10=-257/94, 5-10=0/274, 5-9=-1918/24, 6-9=0/1058, 6-8=-3077/12, 4-11=-2672/133 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11. 8) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 9) This truss has been designed for a total drag load of 240 lb. Lumber DOL=(1.33) Plate grip DOL=(1.33) Connect truss to resist drag loads along bottom chord from 0-0-0 to 1-0-0 for 240.0 plf. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane, Suite 109 Citrus Heights, CA, 95610 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information December 19,2014 Job 03042-14B Truss E3G Truss Type GABLE Qty 1 Ply 1 Lion’s Ridge / Bldg 1/ Roof Job Reference (optional) R43466488 7.600 s Sep 23 2014 MiTek Industries, Inc. Fri Dec 19 09:16:03 2014 Page 1 Alpine Truss, Montrose, CO - 81401 ID:6H?QcMI6c4e8LHnD43dQbjzXm0O-6x39?IpLiwF??EDpeFgQiqXf?_6UFv3nDfw?Zjy7Q8g Scale = 1:42.6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 29 28 27 26 25 24 23 22 21 20 19 18 17 165x10 4x4 4x4 5x5 8x8 21-11-4 21-11-4 21-11-4 21-11-4 0- 3 - 4 7- 7 - 0 4.00 12 Plate Offsets (X,Y)-- [1:0-3-15,Edge], [8:0-4-0,0-4-8], [16:Edge,0-3-8], [22:0-2-8,0-3-0] LOADING (psf) TCLL (Roof Snow=100.0) TCDL BCLL BCDL 100.0 15.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 YES IBC2012/TPI2007 CSI. TC BC WB (Matrix) 0.44 0.69 0.21 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a -0.09 (loc) - - 16 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 130 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x6 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF 1650F 1.5E BRACING- TOP CHORD Structural wood sheathing directly applied or 3-9-13 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 3-0-12 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 21-11-4. (lb) - Max Horz 1=178(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 18, 19, 20, 21, 23, 24, 25, 26, 28 except 1=-1674(LC 27), 16=-129(LC 30), 17=-149(LC 27) Max Grav All reactions 250 lb or less at joint(s) 16 except 1=1820(LC 34), 17=424(LC 24), 18=471(LC 14), 19=458(LC 14), 20=453(LC 14), 21=453(LC 14), 22=463(LC 14), 23=456(LC 14), 24=441(LC 14), 25=396(LC 14), 26=335(LC 1), 27=369(LC 1), 29=1128(LC 14) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-5552/5305, 2-3=-4456/4316, 3-4=-4078/3954, 4-5=-3763/3649, 5-6=-3422/3311, 6-7=-3054/2937, 7-8=-2753/2648, 8-9=-2401/2312, 9-10=-2044/1959, 10-11=-1723/1639, 11-12=-1380/1309, 12-13=-1039/981, 13-14=-699/654, 14-15=-355/299 BOT CHORD 1-29=-5189/5173, 28-29=-4168/4152, 27-28=-3816/3800, 26-27=-3528/3512, 25-26=-3208/3192, 24-25=-2888/2872, 23-24=-2568/2552, 22-23=-2249/2233, 21-22=-1919/1903, 20-21=-1609/1593, 19-20=-1289/1273, 18-19=-969/953, 17-18=-649/633, 16-17=-329/313 WEBS 14-17=-393/76, 13-18=-444/25, 12-19=-431/21, 11-20=-426/24, 10-21=-427/37, 9-22=-437/16, 8-23=-428/65, 7-24=-415/64, 6-25=-368/28, 5-26=-313/17, 4-27=-324/16, 2-29=-989/42 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1 4) Unbalanced snow loads have been considered for this design. 5) All plates are 2x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. Continued on page 2 Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane, Suite 109 Citrus Heights, CA, 95610 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information December 19,2014 Job 03042-14B Truss E3G Truss Type GABLE Qty 1 Ply 1 Lion’s Ridge / Bldg 1/ Roof Job Reference (optional) R43466488 7.600 s Sep 23 2014 MiTek Industries, Inc. Fri Dec 19 09:16:04 2014 Page 2 Alpine Truss, Montrose, CO - 81401 ID:6H?QcMI6c4e8LHnD43dQbjzXm0O-a7dXDepzTENsdOo?CyBfF24qlORj_MJxSJgY5Ay7Q8f NOTES- 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 18, 19, 20, 21, 23, 24, 25, 26, 28 except (jt=lb) 1=1674, 16=129, 17=149. 11) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 12) This truss has been designed for a total drag load of 240 plf. Lumber DOL=(1.33) Plate grip DOL=(1.33) Connect truss to resist drag loads along bottom chord from 0-0-0 to 21-11-4 for 240.0 plf. LOAD CASE(S) Standard Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane, Suite 109 Citrus Heights, CA, 95610 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information ed g e o f t r u s s . fr o m o u t s i d e " 16 /1 -0 PR O D U C T C O D E A P P R O V A L S JO I N T S A R E G E N E R A L L Y N U M B E R E D / L E T T E R E D C L O C K W I S E AR O U N D T H E T R U S S S T A R T I N G A T T H E J O I N T F A R T H E S T T O TH E L E F T . CH O R D S A N D W E B S A R E I D E N T I F I E D B Y E N D J O I N T NU M B E R S / L E T T E R S . W 4 - 6 W3-6 W 3 - 7 W2-7 W1-7 C1-8 C5 - 6 C6 - 7 C7 - 8 C4-5 C3-4 C2 - 3 C1 - 2 TOP CHORD TOP CHORD 8 7 6 5 4 3 2 1 BO T T O M C H O R D S TO P C H O R D S BE A R I N G LA T E R A L B R A C I N G L O C A T I O N In d i c a t e s l o c a t i o n w h e r e b e a r i n g s (s u p p o r t s ) o c c u r . I c o n s v a r y b u t re a c t i o n s e c t i o n i n d i c a t e s j o i n t nu m b e r w h e r e b e a r i n g s o c c u r . Mi n s i z e s h o w n i s f o r c r u s h i n g o n l y . In d i c a t e d b y s y m b o l s h o w n a n d / o r by t e x t i n t h e b r a c i n g s e c t i o n o f t h e ou t p u t . U s e T o r I b r a c i n g if i n d i c a t e d . Th e f i r s t d i m e n s i o n i s t h e p l a t e wi d t h m e a s u r e d p e r p e n d i c u l a r to s l o t s . S e c o n d d i m e n s i o n i s th e l e n g t h p a r a l l e l t o s l o t s . 4 x 4 PL A T E S I Z E Th i s s y m b o l i n d i c a t e s t h e re q u i r e d d i r e c t i o n o f s l o t s i n co n n e c t o r p l a t e s . " 16 /1 Fo r 4 x 2 o r i e n t a t i o n , l o c a t e pl a t e s 0 - Ce n t e r p l a t e o n j o i n t u n l e s s x , y of f s e t s a r e i n d i c a t e d . Dim e n s i o n s a r e i n f t - i n - s i x t e e n t h s . Ap p l y p l a t e s t o b o t h s i d e s o f t r u s s an d f u l l y e m b e d t e e t h . 1 "4/3 PL A T E L O C A T I O N A N D O R I E N T A T I O N Sy m b o l s Nu m b e r i n g S y s t e m 1. A d d i t i o n a l s t a b i l i t y b r a c i n g f o r t r u s s s y s t e m , e . g . d i a g o n a l o r X - b r a c i n g , i s a l w a y s r e q u i r e d . S e e B C S I . 2. T r u s s b r a c i n g m u s t b e d e s i g n e d b y a n e n g i n e e r . F o r w i d e t r u s s s p a c i n g , i n d i v i d u a l l a t e r a l b r a c e s t h e m s e l v e s m a y r e q u i r e b r a c i n g , o r a l t e r n a t i v e T o r I b r a c i n g s h o u l d b e c o n s i d e r e d . 3. N e v e r e x c e e d t h e d e s i g n l o a d i n g s h o w n a n d n e v e r s t a c k m a t e r i a l s o n i n a d e q u a t e l y b r a c e d t r u s s e s . 4. P r o v i d e c o p i e s o f t h i s t r u s s d e s i g n t o t h e b u i l d i n g d e s i g n e r , e r e c t i o n s u p e r v i s o r , p r o p e r t y o w n e r a n d a l l o t h e r i n t e r e s t e d p a r t i e s . 5. C u t m e m b e r s t o b e a r t i g h t l y a g a i n s t e a c h o t h e r . 6. P l a c e p l a t e s o n e a c h f a c e o f t r u s s a t e a c h j o i n t a n d e m b e d f u l l y . K n o t s a n d w a n e a t j o i n t l o c a t i o n s a r e r e g u l a t e d b y A N S I / T P I 1 . 7. D e s i g n a s s u m e s t r u s s e s w i l l b e s u i t a b l y p r o t e c t e d f r o m t h e e n v i r o n m e n t i n a c c o r d w i t h A N S I / T P I 1 . 8. U n l e s s o t h e r w i s e n o t e d , m o i s t u r e c o n t e n t o f l u m b e r s h a l l n o t e x c e e d 1 9 % a t t i m e o f f a b r i c a t i o n . 9. U n l e s s e x p r e s s l y n o t e d , t h i s d e s i g n i s n o t a p p l i c a b l e f o r u s e w i t h f i r e r e t a r d a n t , p r e s e r v a t i v e t r e a t e d , o r g r e e n l u m b e r . 10 . C a m b e r i s a n o n - s t r u c t u r a l c o n s i d e r a t i o n a n d i s t h e r e s p o n s i b i l i t y o f t r u s s f a b r i c a t o r . G e n e r a l p r a c t i c e i s t o c a m b e r f o r d e a d l o a d d e f l e c t i o n . 11 . P l a t e t y p e , s i z e , o r i e n t a t i o n a n d l o c a t i o n d i m e n s i o n s i n d i c a t e d a r e m i n i m u m p l a t i n g r e q u i r e m e n t s . 12 . L u m b e r u s e d s h a l l b e o f t h e s p e c i e s a n d s i z e , a n d i n a l l r e s p e c t s , e q u a l t o o r b e t t e r t h a n t h a t s p e c i f i e d . 13 . T o p c h o r d s m u s t b e s h e a t h e d o r p u r l i n s p r o v i d e d a t s p a c i n g i n d i c a t e d o n d e s i g n . 14 . B o t t o m c h o r d s r e q u i r e l a t e r a l b r a c i n g a t 1 0 f t . s p a c i n g , o r l e s s , i f n o c e i l i n g i s i n s t a l l e d , u n l e s s o t h e r w i s e n o t e d . 15 . C o n n e c t i o n s n o t s h o w n a r e t h e r e s p o n s i b i l i t y o f o t h e r s . 16 . D o n o t c u t o r a l t e r t r u s s m e m b e r o r p l a t e w i t h o u t p r i o r a p p r o v a l o f a n e n g i n e e r . 17 . I n s t a l l a n d l o a d v e r t i c a l l y u n l e s s i n d i c a t e d o t h e r w i s e . 18 . U s e o f g r e e n o r t r e a t e d l u m b e r m a y p o s e u n a c c e p t a b l e e n v i r o n m e n t a l , h e a l t h o r p e r f o r m a n c e r i s k s . C o n s u l t w i t h p r o j e c t e n g i n e e r b e f o r e u s e . 19 . R e v i e w a l l p o r t i o n s o f t h i s d e s i g n ( f r o n t , b a c k , w o r d s a n d p i c t u r e s ) b e f o r e u s e . R e v i e w i n g p i c t u r e s a l o n e i s n o t s u f f i c i e n t . 20 . D e s i g n a s s u m e s m a n u f a c t u r e i n a c c o r d a n c e w i t h A N S I / T P I 1 Q u a l i t y C r i t e r i a . Fa i l u r e t o F o l l o w C o u l d C a u s e P r o p e r t y Da m a g e o r P e r s o n a l I n j u r y Ge n e r a l S a f e t y N o t e s * Pl a t e l o c a t i o n d e t a i l s a v a i l a b l e i n M i T e k 2 0 / 2 0 so f t w a r e o r u p o n r e q u e s t . In d u s t r y S t a n d a r d s : 6- 4 - 8 di m e n s i o n s s h o w n i n f t - i n - s i x t e e n t h s ( D r a w i n g s n o t t o s c a l e ) ' 2 0 1 2 M i T e k fi A l l R i g h t s R e s e r v e d MiT e k E n g i n e e r i n g R e f e r e n c e S h e e t : M I I - 7 4 7 3 r e v . 0 1 / 2 9 / 2 0 1 3 WE B S ed g e o f t r u s s . fr o m o u t s i d e " 16 /1 -0 IC C - E S R e p o r t s : ES R - 1 3 1 1 , E S R - 1 3 5 2 , E S R 1 9 8 8 ER - 3 9 0 7 , E S R - 2 3 6 2 , E S R - 1 3 9 7 , E S R - 3 2 8 2 JO I N T S A R E G E N E R A L L Y N U M B E R E D / L E T T E R E D C L O C K W I S E AR O U N D T H E T R U S S S T A R T I N G A T T H E J O I N T F A R T H E S T T O TH E L E F T . CH O R D S A N D W E B S A R E I D E N T I F I E D B Y E N D J O I N T NU M B E R S / L E T T E R S . W 4 - 6 W3-6 W 3 - 7 W2-7 W1-7 C1-8 C5 - 6 C6 - 7 C7 - 8 C4-5 C3-4 C2 - 3 C1 - 2 TOP CHORD TOP CHORD 8 7 6 5 4 3 2 1 BO T T O M C H O R D S TO P C H O R D S BE A R I N G In d i c a t e s l o c a t i o n w h e r e b e a r i n g s (s u p p o r t s ) o c c u r . I c o n s v a r y b u t re a c t i o n s e c t i o n i n d i c a t e s j o i n t nu m b e r w h e r e b e a r i n g s o c c u r . 4 x 4 PL A T E S I Z E Th i s s y m b o l i n d i c a t e s t h e re q u i r e d d i r e c t i o n o f s l o t s i n co n n e c t o r p l a t e s . " 16 /1 Fo r 4 x 2 o r i e n t a t i o n , l o c a t e pl a t e s 0 - 1 "4/3 PL A T E L O C A T I O N A N D O R I E N T A T I O N Sy m b o l s Nu m b e r i n g S y s t e m Ge n e r a l S a f e t y N o t e s * Pl a t e l o c a t i o n d e t a i l s a v a i l a b l e i n M i T e k 2 0 / 2 0 so f t w a r e o r u p o n r e q u e s t . In d u s t r y S t a n d a r d s : AN S I / T P I 1 : N a t i o n a l D e s i g n S p e c i f i c a t i o n f o r M e t a l P l a t e C o n n e c t e d W o o d T r u s s C o n s t r u c t i o n . DS B - 8 9 : D e s i g n S t a n d a r d f o r B r a c i n g . BC S I : B u i l d i n g C o m p o n e n t S a f e t y I n f o r m a t i o n , G u i d e t o G o o d P r a c t i c e f o r H a n d l i n g , I n s t a l l i n g & B r a c i n g o f M e t a l P l a t e C o n n e c t e d W o o d T r u s s e s . 6- 4 - 8 di m e n s i o n s s h o w n i n f t - i n - s i x t e e n t h s WE B S S Y P r e p r e s e n t s v a l u e s a s p u b l i s h e d b y A W C i n t h e 2 0 0 5 / 2 0 1 2 N D S S P r e p r e s e n t s A L S C a p p r o v e d / n e w v a l u e s w i t h e f f e c t i v e d a t e o f J u n e 1 , 2 0 1 3 So u t h e r n P i n e l u m b e r d e s i g n a t i o n s a r e a s f o l l o w s : 24 " O . C . 24 " O . C . (8)HUS28 (8 ) H U S 2 8 A1G B1G BX G D D1G D1G E3GE2G D1DB1AG A1G BX G D B1D D1D B1D B1 D1D B1D D1D B1D D1DB1(2) B1(5) B1(5) B1(5) D1(3) D1(5) D 1 (5) D1(3) D1(5) A1(5) E1(8 ) E1(8 ) D2(4) D2( 4 ) E1(9) E2(8) B2( 4) B2(4) D1(3) D1(3) B1(2) B1(2) B1(3) C1(9) C1(9) C1(9) C1(9) 21-05-12 22-09-04 11-03-08 10 - 0 6 - 0 8 5- 1 1 - 0 0 13 - 0 8 - 0 8 17 - 0 7 - 0 0 8-05-08 2- 1 0 - 0 0 13 - 0 8 - 0 8 5- 1 1 - 0 0 11-03-08 21 - 0 4 - 0 0 5- 1 1 - 0 0 8-05-08 2- 1 0 - 0 0 13 - 0 8 - 0 8 16-05-08 13-08-085-11-00 11-03-0810-08-00 21-11-04 10-01-0030-09-04 5-11-008-05-08 33-04-00 2- 1 0 - 0 0 11 - 0 6 - 0 0 8-05-08 5- 1 1 - 0 0 11-03-08 20 - 0 7 - 0 0 5- 1 1 - 0 0 8-05-08 2- 1 0 - 0 0 11 - 0 6 - 0 0 21 - 0 7 - 0 8 11 - 0 6 - 0 0 5- 1 1 - 0 0 11-03-08 10 - 0 3 - 0 8 Building#-1 RoofTrussLayout Lion'sRidgeApartmentHomes 1280NorthFrontageRdWestVail,CO RoofArea:10823.63|HipLines:0|RidgeLines:163.08 FasciaLines:346.17|RakedFascia:860.95|Valley:061408JayJayRoadMontrose,CO81401 Office:970.249.0801Fax:970.249.1296 Date:11/12/2014