HomeMy WebLinkAboutSEI14-P103 Timber Ridge Bldg N Unit 3 Asbestos Consulting Services
PROJECT
AIR MONITORING REPORT
TIMBER RIDGE APARTMENTS
1280 NORTH FRONTAGE ROAD WEST
VAIL, COLORADO
81657
BUILDING “N”
UNIT #3
PREPARED FOR:
Eco Tech Environmental Inc. 2331 West Hampden Avenue Suite 137 Sheridan, Colorado 80110
Report Prepared: July 20, 2014
SEI Project Number: SEI14-P103
Prepared By:
Sunrise Environmental, Inc.
371 Crest View Drive Black Hawk, Colorado 80422 Phone: 720-209-5282
www.sunrise-enviro.com
EXECUTIVE SUMMARY
Sunrise Environmental, Inc. (SEI) provided air monitoring services for Eco Tech Environmental
Inc. (ETE) at the Timber Ridge Apartments, Building N, Unit #3, 1280 North Frontage Road West, Vail, Colorado 81657 on July 18, 2014. The field representative for SEI was Mr. Scott D.
Sanders. Work was performed in conjunction with asbestos abatement at the site. Asbestos
abatement was conducted by ETE; a Colorado Department of Public Health & Environment
(CDPHE) licensed General Abatement Contractor (GAC).
SEI’s scope of work included collection and analysis of final clearance air samples, performing a
visual inspection of the work area prior to collection of air samples, and assembling project
documentation.
Subsequent to cleanup, SEI visually inspected the containment areas for visible dust and debris. Upon passage of visual inspection, SEI collected final clearance air samples and notified ETE
when laboratory results indicated airborne fiber concentrations were not in excess of 0.01f/cc as
required by CDPHE Regulation No. 8.
At project completion, air-monitoring results indicate concentrations of airborne fibers were not in excess of 0.01f/cc as required by the Environmental Protection Agency (EPA) and CDPHE for
re-occupancy following asbestos abatement.
CLIENT: Eco Tech Environmental Inc.
2331 West Hampden Avenue
Suite 137 Sheridan, Colorado 80110
PROJECT
LOCATION: Timber Ridge Apartments
1280 North Frontage Road West Vail, Colorado 81657
Building N, Unit #3
DESCRIPTION OF WORK: Final Visual Inspection & Final Clearance Air Monitoring
ASBESTOS
ABATEMENT CONTRACTORS: Eco Tech Environmental Inc.
SUNRISE
ENVIRONMENTAL INC. REPRESENTATIVE: Mr. Scott D. Sanders
INTRODUCTION
SEI provided air monitoring services for ETE at the Timber Ridge Apartments, Building N, Unit
#3, 1280 North Frontage Road West, Vail, Colorado 81657 on July 18, 2014. The field
representative for SEI was Mr. Scott D. Sanders. Work was performed in conjunction with the
removal of asbestos containing building materials at the site. Asbestos abatement was conducted
by ETE; a Colorado Department of Public Health and Environment (CDPHE) licensed General Abatement Contractor (GAC).
SEI performed the final visual inspection, and the collection and analysis of Phase Contrast
Microscopy (PCM) air samples after asbestos abatement. SEI successfully participates in the
AIHA Proficiency Analytical Testing (PAT) Program (Laboratory ID# 196102). All SEI analysts have been certified in NIOSH 582E to perform collection and analysis of PCM air
samples.
SCOPE OF WORK
ETE’s scope of work for this project consisted of the removal/disposal of:
1. Approximately 150 square feet of sheet vinyl flooring was removed from the kitchen,
dining area, and entryway.
SEI has performed the following Industrial Hygiene services:
• Performed a visual inspection of the abatement areas,
• Collection and analysis of PCM air samples to monitor concentrations of airborne fibers after asbestos abatement in accordance with CDPHE Regulation No. 8,
• Assembled and submitted project documentation.
The findings set forth in this report are strictly limited in time and scope to the date of the
evaluation. The conclusions presented in the Report are based solely on the services described
therein, and not on scientific tasks or procedures beyond the scope of agreed upon services. SEI
was not responsible for determining which asbestos-containing materials were to be included in the abatement scope of work.
PROJECT DESCRIPTION
Sequence of field work: Table 1 summarizes the field work in the order in which it was
completed.
Table 1. Summary of Field Work
DATE FIELD WORK
07-18-14 Pre-clearance visual inspection of the containment is performed. (ETE,
SEI)
Collection of five (5) PCM final clearance air samples inside the
containment. (SEI)
All PCM clearance samples are below 0.01f/cc. ETE on-site supervisor is notified. (SEI) AIR MONITORING
Sample Collection The effective filter area for samples collected on July 18, 2014 was 385mm2. PCM samples
were collected on 25 millimeter (mm) mixed cellulose ester membrane filters (0.8 micron pore
size). The filters were preassembled by the manufacturer. Air samples were collected at a flow
rate of 15.6 to 15.7 liters per minute (LPM). Flow rates were recorded at the beginning and at the end of the sampling period using a DryCal™ Primary Standard flow calibrator. All air samples were collected open-faced and positioned at breathing zone height (approximately five
feet above the floor) with exposed portion of the cassette facing downward. Clearance air
samples were collected aggressively and in accordance with CDPHE Regulation #8. (See
Appendix A for sample data) PCM Analysis Methodology
PCM samples were analyzed by SEI according to the NIOSH 7400 Method (“A” counting rules).
This method can be found in the NIOSH Manual of Analytical Methods. All air sample results are calculated with blank corrections, checked and reviewed. Unused portions of samples are archived three months unless client requests special handling. Laboratory analysis was
accomplished utilizing a Phase Contrast Microscope. Size and fiber counts were performed at
400X magnification. The microscopy field area (MFA), defined by the Walton-Beckett
Graticule is 0.00785mm2.
Report Data Key
Fbrs/Flds: Fibers per fields; total fibers counted over total areas examined.
LOD: Limit of Detection; the calculated lower limit of detection expressed in fibers per
cubic centimeter. Based on limit of detection of (5.5/100 fibers/field). F/cc: Fibers per cubic centimeter. ≤ LOD: Less than or equal to the limit of Detection; thus, the analytical result is less than
or equal to the value indicated in the LOD column.
CONCLUSIONS
At project completion, air-monitoring data indicate concentrations of airborne fibers were not in
excess of 0.01f/cc as required by the Environmental Protection Agency (EPA) and CDPHE for
re-occupancy following asbestos abatement.
Reviewed and signed for the company by:
_________________________________
Scott D. Sanders
President
APPENDIX A
PCM AIR SAMPLE DATA
SUNRISE ENVIRONMENTAL, Inc.
Phase Contrast Microscopy Sampling Data Sheet
PROJECT
DATE: July 18, 2014
PROJECT NUMBER: SEI14-P103
CLIENT: Eco Tech Environmental Inc. 2331 W. Hampden Avenue
Suite 137
Sheridan, Colorado 80110 PROJECT
ADDRESS: Timber Ridge Apartments
1280 North Frontage Road West Vail, Colorado 81657 Building N, Unit 3
Sample (Time) Total (Flow Rate (l/min) Total Fibers/
Number Start Stop Minutes Start Stop Avg. Volume Field LOD Fibers/cc
0718-01 --- --- --- --- --- --- --- 0/100 --- ---
0718-02 --- --- --- --- --- --- --- 0/100 --- ---
0718-03 1314 1425 71 15.6 15.6 15.6 1108. 2.5/100 .002 ≤ LOD
0718-04 1314 1425 71 15.6 15.6 15.6 1108. 0/100 .002 ≤ LOD
0718-05 1315 1426 71 15.6 15.6 15.6 1108. 1/100 .002 ≤ LOD
0718-06 1316 1427 71 15.6 15.8 15.7 1115. 2/100 .002 ≤ LOD
0718-07 1316 1428 72 15.6 15.6 15.6 1123. 1.5/100 .002 ≤ LOD
Sample Sample
Number Type Location/Description Results
0718-01 Field Blank 0/100 0718-02 Field Blank 0/100 0718-03 CLEARANCE Building N, Unit 3, kitchen, north side ≤ LOD
0718-04 CLEARANCE Building N, Unit 3, kitchen, south side ≤ LOD
0718-05 CLEARANCE Building N, Unit 3, kitchen, west side ≤ LOD
0718-06 CLEARANCE Building N, Unit 3, kitchen, east side ≤ LOD 0718-07 CLEARANCE Building N, Unit 3, kitchen, center ≤ LOD
LOD= Limit of Detection
APPENDIX B VISUAL INSPECTION FORM
APPENDIX C
CERTIFICATIONS