NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TMES
MECHANICAL PERMIT PCrMit #: MO4-0207
Job Address: 4575 MEADOW DR VAIL Status . . . : ISSUED
Location.....: TIMBERFALLS CONDOS #1002 Applied. . : 0913012004
Parcel No...: 210112302002 Issued. . : lLll4l2\04
Project No , {0 F Expires . .: O4ll2l200s
OWNER DTETRICH, FREDERTCK W. 09/30/2004 Phone:
451,4 E MEADOW DR 1002
VAII-,co 81657
License:
CONTRACTOR ROD HALL COMPANY 09/30/2004 Phone: 303-777-7700
255 WYANDOT STREET
DENVER, CO
80223
License:150-M
APPLICANT ROD HALL COMPANY 09/30/2004 Phone: 303-111-1100
255 WYANDOT STREET
DENVER. CO
80223
License:150-M
Desciption: COI\I/ERT WOOD TO GAS. MENDOTA D-30, 30,000 BTU'S, WARNOCK
HERSEY, CGA/AGA/ANS/STD
Valuation: $3,000.00
Fireplace Inforrnation: Resn'icted: Y # ofcas Appliances: 0 #ofGas Logs: 0 #of Wood Pellet: 0r'.':**:r*r.**:r:**:*r:*rr I FEE SUMMARY
Mechanical--> 560.00 Restuarant Plan Review-> 50.00 Tolal Calculatcd Fe'es---> 578.00
Plan Check*-> Sl-5 . 00 DRB Fee-----------> S0 . 00 Additional Fees---------> (S78 - 00 )
lnvesrigation-> 50-00 TOTAL FEES---_> S?8.00 Total Peamit Fee-------> S0.00
Will Call-----> S3 . 00 Payments------------> S0 . 00
BALANCE DUE____-> SO. OO
Item: 05100 BUILDING DEPARTMENTI0/II/2004 cCD Action: AP
Item: 05500 FTRE DEPARTMENT
CONDITION OF APPROVAL
Cond:12
(BI-,DG. ) : FIELD INSPECTIONS ARE REQUIRED T0 CHECK FOR CODE COMPLIANCE.
Cond:. 22
(BLDG.): COMBUSTION AIR IS REQUIRED PER SEC. 701 OF THE l-997 IJMC, OR SECTION
701 0F THE 1997 rMC.
Cond:23
(BLDG. ) : INSTALLATTON MUST CONFORM TO MANUFACTURES TNSTRUCTIONS AND TO CHAPTER
10 OF THE 1-99'7 UMC, CHAPTER 10 OF THE 1997 IMC.
Cond:25
(BI-,DG.): GAS APPI-,IANCES SHALI-, BE VENTED ACCORDING fO CHAPTER 8 AND SHALL
TERMINATE AS SPECIFIED IN SEC.8O5 OF THE 1997 IJMC, OR C}IAPTER 8 OF THE 1997 IMC.
Cond:29(BLDG.): ACCESS TO HEATING EQUIPMENT MUST COMPLY WITH CIIAPTER 3 AND SEC.1017 OF
THE 1997 IJMC AND CHAPTER 3 OF THE 1997 IMC.
Cond: 31
(BI-,DG. ) : BOILERS SHALL BE I.{OIJNTED ON FLOORS OF NONCOMBUSTIBLE CONST. ITNLESS.I,ISTED FOR MOI'NTING ON COMBUSTIBLE FLOORTNG.
Cond: 32(BLDG.): PERMIT,PLANS AlfD CODE ANALYSIS MUST BE
TO AN TNSPECTION REQUEST.
Cond: 30
(BLDG. ) : DRAINAGE OF MECHANICAL ROOMS CONTAINING
BOTI,ERS SHAI,I-, BE EQUIPPED WITH A FLOOR DRATN PER
sEcrroN 1-004.5 0F THE 1997 rMC.
POSTED IN MECHANICAL ROOM PRIOR
HEATING OR HOT-WATER SUPPLY
sE.c. 1,022 0F THE 1997 In4C, OR
DECLARATIONS
I hereby acknowledge that I have read this application, flrlled out in full the information required, complaed an accurate plot plan,
and state that all the information as required is correct. I agre€ to comply with the information and plot plan, to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, Uniform Building Code and other ordinances of the Town applicable thereto.
RIjQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOI.]R HOURS rN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM - 4 PM.C,A
SIGNATIJRE OF OWNER OR CONTRACTOR FOR HMSELF AND OWNER
NVNupVilL
75 5. Frontegn Rd.
A!4 WL *P 3A '@4 t1'129
rttucA'Tlot wlrl ilof lt lcctFrED r ulcoilPtlTloR UlllttcrlD
?roJr<t f:
SulHlrrg Pcfmlt f:
Hcdpnlcal Prrmlt #:
97G.179-2{18 (lnqprctlonr)
Room l.ayout drewn to lcale to Indudc:
H"is 1
Cut/SPGG Shcctl
Permit wtll not be acr:epted wlthout the following:
no tcrdrcss:451
Snbdlvlslon:
Work Class: t{ct{ ( } Addltbtt ( )Alg.Uon Rcpar( ) OUt€r( )
Ooes an EHU cxist at 0ris locatbn:YGs( ) t{o(
r*nctOet ) Rcrtaunnt( I Otftcrff)
-
ffirnodatlon unlB ln thb hrildltE:
loffypc ot Ffrpbel Plopoccd: Gar Appllrc g (NCITAtLowED)
cotrtptETE VALU TIOT FOR llEclr^tltcAt PERtllT (labor e Hatcdtlt)
D N<,
COilTRACTOR I lltORl'lATIOt{
.................or............r..r1rtX1i OIXIGE l|!l! OlllYtrrf rrrrr'ltrtrol"'tr]"'f""'t"" r
1r
EL4 PAz
MENDOTA GAS IIIREPLACE INSENT ,
SPECIFICATIOIIS E CLEARANCES
:_rll' 23 3/8
-T
I
I
II
l+- g' MAx. MANTEL
I DEPIH (fvtDrH )
? l" MtN.
FROU TOP
OF ORILL
TO MANTII
n 7/16
BRASS TRIM I5/6_4t
fM REMO\ABLE
FOR INSTATLAITON
1J/ 16
!
F-so t/4-l
FRONT VIEW
s/8
30 7/t6
22 1/4
TOP. VIEW
I2" IilIN. CLEARANCE TO STDEWALL
C
14 1/6
s s/16
I)-30 Sunounl DEGnrFDl
A B.hdr!||0n.lnclcr ms.
,7 1 6t6 .10 l0t6
30. i 'r,{1Q2.,:4 nIt
$4th Bn$Tltn 27 3il6 691 4031t6 I02l
t03lt6 767 443^6 ll?,,