HomeMy WebLinkAboutFirst Westwind Site Analysis 02/05/07
Westwind Site Analysis:
Site Area: 0.84911 acres; 36,987 square feet
Zoning: Lionshead Mixed Use 1
Development Stats
Standard Allowed Existing
Setbacks
(min.):
Front: 10’ 53’
East Side: 10’ 31’
West Side: 10’ 26’
Rear: 10’ 6.5’
Height:
Average: 71’ ~55’
Maximum: 81.5’ ~65’
Density (max): 29
DU’s (35/ac)* 35 DU’s
*Or a 33% increase from existing, whichever is greater.
GRFA (sq. ft. max):
TOTAL: 92,467 34,458
Floor 1: 8623
Floor 2: 9411
Floor
3: 9492
Floor 4: 6932
Site coverage (max.): 70% (25,890.9 sq. ft.) 37.5% (13,865 sq. ft.)
Landscaping (min.): 20% (7397.4 sq. ft.) 28% (10,403 sq. ft.)
Parking
(min.): 1.4/DU (53.2) 48 total (14 surface, 34 covered)
Disclaimer: This site analysis is based on plans and analysis on file from 1996. No new additions since then
are apparent from the building permits on file. The statistics for existing conditions would need to be verified with new architectural plans.