HomeMy WebLinkAboutB15-0064 corrections required Date: 3/31/2015 Re: B15-0064 100 E Meadow Drive Unit # 101 Dear Mr. Heid, RESPONSE INSTRUCTIONS ● Submit two complete sets of revised construction documents containing the requested information with all plan revision items clouded or otherwise identified. ● Please respond in writing to each comment with a response letter addressing each comment. BUILDING COMMENTS Architectural Comments: Sheet C 1. Revise plans to reflect current designations for occupancy classifications. Reference section 302.1 IBC 2. Annotate on plans the required fire rating for the structural elements to be influenced by the proposed construction. Reference Table 601 IBC 3. Indicate on the plans the rating for required fire assembly separation and shafts proposed. Reference Chapter 7 of the IBC 4. Clarify scope of work. Application and plans conflict. Reference section 107.2 IBC 5. Provide mechanical, electrical, gas piping, and plumbing plans sealed by a registrant licensed in the State of Colorado. Reference section 107.2 IBC and State of Colorado Registrant rules and regulations. 6. Provide structural design for the proposed gunite pool reviewed and accepted by the engineer of record. Reference section 107.2 IBC ILC Survey 1. Survey to be sealed and signed by registrant per Colorado registrant rules and regulations. P1 1. Plans to be sealed and signed by registrant per Colorado registrant rules and regulations. Town of Vail Page2 Sheet A1.0 1. Provide details of required fire rated assemblies and cross reference on plans. Reference section 107.2 IBC Sheet A1.1 1. Provide detail of proposed fire proofing indicated on plans. Reference section 704 IBC 2. Provide architectural, mechanical, electrical, and plumbing plans for the proposed new mechanical room. Reference section 107.2 IBC Sheet A1.2 1. Provide gas piping plans by a licensed registrant for the proposed fire pit and bar-b- que to include sizing of appliance, materials to be used, fire penetrations, pressures to be used, and developed length of piping. Reference section 107.2 IBC Also show compliance with the towns building code as amended for fire pits. 2. Provide references to details of proposed guardrails showing compliance with the building code. Reference section 1013 IBC Sheet A1.3 1. Provide architectural details/ cross section for proposed addition showing compliance with the building, energy and electrical code. Sheet A2.1 1. Clarify scope of work as request on Sheet C. Sheet A3.2 1. Identify fire rated assembly to be used in detail 1. Structural Comments: Sheet S1 1. Provide structural design for the proposed gunite pool reviewed and accepted by the engineer of record. Reference section 107.2 IBC 2.Clarify pool loads in design criteria 3. Plans to reflect design for proposed guards as per section 1603.1.8 and 1607.8 IBC Plumbing Comments: 1. Provide plans by a registrant licensed in Colorado as indicated in the architectural comments. Mechanical Comments: 1. Provide plans by a registrant licensed in Colorado as indicated in the architectural comments Electrical Comments: 1. Provide plans by a registrant licensed in Colorado as indicated in the architectural comments Town of Vail Page3 Sheet E1 1. Plans to be sealed by a registrant licensed in Colorado. PLANNING COMMENTS Reviewed and accepted FIRE COMMENTS Revisions to the fire alarm and suppression system requires a permit from the fire department. PUBLIC WORKS COMMENTS Obtain a permit for any staging to be done in the public right of way prior to work Sincerely, Martin A. Haeberle Chief Building Official