HomeMy WebLinkAboutB13-0552 B14-0032 Steel inspection Department of Community Development
75 South Frontage Road
TOWN OF VAIL' va�i, co s�ss7
Tel: 970.479.2128
www.vailgov.com
Development Review Coordinator
TRANSMITTAL FORM
Use this form when submitting additional information for planning applications or building permits.
This form is also used for requesting a revision to building permits. A two hour minimum building review
fee of$110 will be charged upon reissuance of the permit.
Application/Permit#(s)information applies
to: Attention: (�Revisions
B14-0032 Martin Haerbele Q Response to Correction Letter
�attached copy of correction letter
B13-0552 Martin Haerbele Q Deferred Submittal
�Other ��s�^s�^���
Project Street Address:
463 Beaver Dam RD
(Number) (Street) (Suite#)
Building/Complex Name: Zekelmen Description of Transmittal/List of Changes, Items Attached:
Steel reinforcement inspections for First 10'-1-3.5E and 1-4W and H-B,
Applicant Information
First 10'-1-3.5E and 1-4W and H-B,4.H-G and G.4-5 and wall
(architect,contractor,owner/owner's rep)
6.1-4 and 4.B-E and wall E4-5, 1-4 and G-H
Contact Name: RA Nelson
Address: 51 Eagle Road#2
City Avon State: CO ZiP; 81620
Contact Name: Grant Smith
(use additional sheet if necessary)
Contact Phone: 970-391-9736
Building Permits:
gsmith@ranelson.com Revised ADDITIONAL Valuations(Labor 8�Materials)
Contact E-Mail: (DO NOT include original valuation)
I hereby acknowledge that I have read this application,filled out Building: $
in full the information required,completed an accurate plot plan,
and state that all the information as required is correct. I agree to Plumbing: $
comply with the information and plot plan,to comply with all Town
ordinances and state laws, and to build this structure according Electrical: $
to the town's zoning and subdivision codes, design review ap-
proved,Intemational Building and Residential Codes and other Mechanical: $
ordinances of the T ap ' to.
X Total: $�
Owner/Owner's Repr ta' (Required)
a son.com,
CO ra Nel N-Cory
� Date:207 Date Received:
10:00:74-
, ...�, �. . . �. ... >_ � � � � l:/ �
D
For Ot1'ice Use Only: . �y(�
Fee Paid:
r`ii i� lr <� L�J��
Received From:
casn Check# TOWN OF VAI L
CC: vsa/MC Last 4 CC# exp.date:
Authorization#
�,..�� 5020 County Road 154
Gienwood Springs,CO 81601
Phone:970-945-7988
Fax:970-945-8454
HEPWORTH-PAWLAK GEOTECHNICAL hoaeo�lhos�eobech.com
REINFORCEMENT STEEL INSPECTION REPORT
Client: Trademark Construction Services Job No.: 112 330B Day: Thursday
Attn: Brian McAndrews Date: 1/15/15
555 S. Old Woodward Ave.Suite 25L Page: 1 of 1
Birmingham, Michigan 48009
Project: Special Inspections and Construction Observation and Testing, Proposed Zekeiman Residence,
Lot 5,Biock 4,Vail Viliage Third Filing,463 and 473 Beaver Dam Road�Vail, Colorado
_ _..�_.____ ._�.__ _ ..__ .._ _..
Area of inspection: Walis to 10 feet below top of waii, Lines 1 to 3.5 on east side, 1 to 4 on
west side, and H to B on north side
_ma______._.. �_.__ ��_��._ ___.__�.__e____.______r._.,_.__
Reference Documents Structural Drawing provided on site, Sheet 312, Waii Types FW1, FVY3, 8�
Used: F1N4
Inspection Notes: Reinforcing about 90% complete and inside forms not yet in place{at time
of inspection.
Inspection Status: � Preliminary ❑ Final
� Concrete reinforcement as noted above was judged to be in reasonable conformance with the
referenced construction documents.
❑ Exceptions Noted:
_ _ _ __._.__ .__�_�.___.�..__.__--�_......__._
Verbal Danny with RA Nelson was informed of our inspection results. Final
Communication: inspection was requested on Monday, January 19, 2015.
____ __ -- ----_ — - ---_ _---_ ..__-- - ____ _.___._._ _._-- __.__. . _ _ _ _
Distribution:
Trademark Construction Services-B�ian McAndrews(brian�ltradsmarlcmi.com)
R.A.Nelson 8 Associates-G�ant Smlth(�mith�anelson.com)
R.A.Nelson&Associates-Danny Aldaz(daldaz@ranelson.com)
Martin/Martin Engineers-Kevin Hass(KHass�martinmartln-mtn.com)
Martin/Martin Engineers-Sean Molloy(smollov�martinmartin-mtn.com�
Thomas J. Westhoff, CET David A. Young, P.E.
Field Technician Reviewed By
�...j 5020 County Road 154
� Glenwood Spriogs,CO 81601
� Phone:970-945-7988
HEPWORTH-PAWLAK GEOTECHNICAL Fax:970-945-8454
h�aeo�huneotech.com
REINFORCEMENT STEEL INSPECTION REPORT
Client: Trademark Construction Services Job No.: 112 330B Day: Tuesday
Attn: Brian McAndrews Date: 1/20/15
555 S. Oid Woodward Ave. Suite 25L Page: 1 of 1
Birmingham, Michigan 48009
Project: Special Inspections and Construction Observation and Testing, Proposed Zekelman
Residence, Lot 5, Block 4, Vail Village Third Filing, 463 and 473 Beaver Dam Road, Vail,
Colorado
__ __
Area of inspection: Foundation Walls to 10 feet betow top of wall, Lines 1 to 3.5 on east side, `
1 to 4 on west side, and H to B on north side
. ._ _...,_. ,�.. . __.. .. . . _.. , __ ___._..... . _ �
Reference Documents Structural Drawing provided on site, Sheet 312, Wall Types FW1, FW3, 8 :
Used: FW4
_ .. .,.. _._.,... : . ,_ __ _
Inspection Notes: Minor reinforcement bar clearance issues were initiaily noted and were
corrected to prior to concrete placement.
Inspection Status: ❑ Preliminary � Final
� Concrete reinforcement as noted above was judged to be in �easonable conformance with the
referenced construction documents.
❑ Exceptions Noted:
... ._ _. ... ., _ ,
Verbal Danny with RA Nelson was informed of our inspection results. ;
Communication:
Distribution:
Trademark Constructlon Services-Brian McAndrews(brian�trademarkml.com)
R.A.Nelsan 8�Associates-Grant Smith(s�smlth�ranelson.com)
R.A. Nelson 8 Associates-Danny Aldaz(daldaz�ranelson.com)
Martin/Martin Engineers-Kevin Hass(KHass�rnartinmartl�-mtn.com)
Martin/Martin Engineers-Sean Molloy(amollov�martlnmartfn-mtn.coml
KH Webb Architects-Stacey Gcering(stacev�khwebb.com)
Thomas J. Westhoff, CET David A. Young, P.E.
Field Technician Reviewed By
H� 5020 Coonty Road 154
�� Glenwooc!Springs,CO 89601
Phone:970-94.�7988
Fax:970-945-8454
HEPWORTN-PAWLAK GE07ECHNICAL haaeo hps�eotech.com
REINFORCEMENT STEEL INSPECTION REPORT
Client: Trademark Construction Services Job No.: 112 330B Day: Friday
Attn: Brian McAndrews Da#e: 2/6/7 5
555 S. Otd Woodward Ave. Suite 25L Page: 1 of 1
Birmingham, Michigan 48009
Project: Special Inspections and Construction Observation and Testing, Proposed Zekelman
Residence, Lot 5� Biock 4, Vail Village Third Fi[ing, 463 and 473 Beaver Dam Road, Vail,
Colorado
Area of Inspection: Foundation Walls to Elevation 109� Line H, 1 to 4, 1, G to H, and 4, G to H
Refe�ence Dacuments Structural Drawing provided on site, Sheet S312, S393� and S314
Used:
Inspection Notes:
fnspection Status: ❑ Preliminary � Final
� Concrete reinforcement as noted above was judged to be 'rn reasonabte confoRnance with the
referenced construction documents.
❑ Exceptions Noted:
Verbal Danny with RA Nelson was informed of our inspecfion results.
Communication:
Distribution:
Trademark Construction Services-Brian McAndrews tbrianC�trademarkmi.com)
R.A.Nelson&Associates--Grant Smith(ssmith(a�ranefson.coml
R.A.Nelson 8 Associates-Danny Aldaz(daldazCa�raoelson.com)
Martln/Martin Engineers-Kev�n Hass(KHaas6�martinmartin-mtn.coml
Martin/Martin Engineers-Sean Molloy(smollov[�martinmartin-mtn.coml
KH Webb Archltects-Stacey Goering(stacev[a�khwebb.com)
Thomas J.Westhoff, CET David A.Young, P.E.
Field Technician Reviewed By
j.�..j� 5020 Cou�ty Road 754
Glenwood Springs,CO 81601
Phone:970 945 7988
Fax:970-945-8454
HEPWORTH-PAWLAK GEOTECHNICAL hos�eo�hqs�eotech.com
REINFORCEMENT STEEL INSPECTION REPORT
Client: Trademark Construction Services Job No.: 112 330B Day: Tuesday
Attn: Brian McAndrews Date: 2/3/15
555 S. Old Woodward Ave. Suite 25L Page: 1 of 1
Birmingham, Michigan 48009
Project: Special Inspections and Construction Observation and Testing, Proposed Zekelman
Residence, Lot 5, Block 4, Vail Village Third Filing, 463 and 473 Beaver Dam Road, Vail,
Colorado
__ .. _ .. ___ . __. __. _ __
Area of lnspection: Foundation Walls 4, H to G and wall G, 4 to 5 and wall B, 1 to 4 and wa114,
BtoEandwallE, 4to5.
. .... . ........ .� ___..,... .. ._ .. __. _...... � .,...___ . ._ : _.. .,.._. . ._ : _
Reference Documents Structural plans sheets S100M, S312
Used:
_ _ ..�... . .. ..__. .__ ___.___, .. �..�. __. _r N..rt_.a r.�.�,....._ . ._..
Inspection Notes: Wall H, 1 to 4 was not inspected at this time because scaffolding was not
completed.
Inspection Status: ❑ Preliminary � Final
� Concrete reinforcement as noted above was judged to be in reasonable conformance with the
referenced construction documents.
❑ Exceptions Noted:
...�._ a �._ ...._.,.��___., _.,.�,_..�.m_�_,.__�,._, :. w.... _� ,. ..�...__s ,., .,,. _._.
Verbal Danny w/RA Nelson was informed that reinforcement was installed
Communication: according to construction documents.
_ __ - _
_ _
Distribution: __ _ _ _
Trademark Construction Services-Brian McAndrews(brlan�trademarlcmi.com)
R.A Nelson 8 Associates-Grant Smith(osmlth�ranelson.com)
R.A.Nelson S Associates-Danny Aidaz(daldaz�ranelaon.com)
Martin/Martin Engineers-Kevin Hass(KHaas�rnartlnmartln-mtn.com)
MartiNMartin Engineers-Sean Molloy(smollov�martinmartln-mtn.com)
KH Webb Architects-Stacey Goering(stecev�tichwebb.com)
Paul Weiser David A. Young, P.E.
Field Technician Reviewed By
H� 5020 County Road 154
Gienwood Springs,CO 81601
Phone:970-945-7988
Fax: 970-945-8454
HEPWORTH-PAWLAK GEOTECHNICAL �pggp�hoaeotech.COm
REINFORCEMENT STEEL INSPECTION REPORT
Client: Trademark Construction Services Job No.: 112 330B Day: Thursday
Attn: Brian McAndrews Date: Z/5/15
555 S. Old Woodward Ave. Suite 25L Page: 1 of 1
Birmingham, Michigan 48009
Project: Special inspections and Construction Observation and Testing, Proposed Zekelman
Residence, Lot 5, Block 4, Vail Village Third Filing, 463 and 473 Beaver Dam Road, Vail,
Colorado
Area of Inspectifln: Foundation Wall, line H, 1 to 4 was cancelled because scaffolding was
still not completed.
__._., _..m,_._.._,_ ,T .,__._,_ ,..,. _.. ._ .. .__. _ . .. ._...,..._._. . _r., .., .,.. _..._
Reference Documents
Used:
._ .,_ .... �__�..�..__...._.�,.._._�___. �.,..�____�. ,_._..,_�_.._.�..._ .. .a..._,_ _.�_.__ ..,...._. _,._.__ �. .
Inspection Notes:
Inspection Status: ❑ Preliminary ❑ Final
❑ Concrete reinforcement as noted above was judged to be in reasonable conformance with the
referenced construction documents.
❑ Exceptions Noted:
. , . ._.._.....�..,. ___R_�._.��......��:_�._�.._w�..,�_.__. .,�__�,,.n�.._...... .��..��_._ . _ .... . . .,.._
Verbal Danny wlRA Nelson was infonned of incompleted scaffolding and that
Communication: reinforcement would be inspected before concrete pour tomorrow.
__
____ _ _
____ . ____ .,____ _ _ _ ___ _ _ __
Distribution:
Trademark Construction Services-Brian McAndrews(bNan�trademarkmi.com)
R.A.Nelson S Associates-Grant Smith(s�smith�ranelson.com 1
R.A.Nelson 8 Associates-Danny Aldaz(daldaz�nnelson.com)
MartiNMartin Engineers-Kevin Hass(KHaas�rnartln artln-mtn.com)
MartiNMartin Engineers-Sean Molloy(smollov�martlnmartin-m�.com)
KH Webb Architects-Stacey Goering(stacev�lchwebb.com)
Paul Weiser David A. Young, P.E.
Field Technician Reviewed By