Loading...
HomeMy WebLinkAboutB13-0552 B14-0032 Steel inspection Department of Community Development 75 South Frontage Road TOWN OF VAIL' va�i, co s�ss7 Tel: 970.479.2128 www.vailgov.com Development Review Coordinator TRANSMITTAL FORM Use this form when submitting additional information for planning applications or building permits. This form is also used for requesting a revision to building permits. A two hour minimum building review fee of$110 will be charged upon reissuance of the permit. Application/Permit#(s)information applies to: Attention: (�Revisions B14-0032 Martin Haerbele Q Response to Correction Letter �attached copy of correction letter B13-0552 Martin Haerbele Q Deferred Submittal �Other ��s�^s�^��� Project Street Address: 463 Beaver Dam RD (Number) (Street) (Suite#) Building/Complex Name: Zekelmen Description of Transmittal/List of Changes, Items Attached: Steel reinforcement inspections for First 10'-1-3.5E and 1-4W and H-B, Applicant Information First 10'-1-3.5E and 1-4W and H-B,4.H-G and G.4-5 and wall (architect,contractor,owner/owner's rep) 6.1-4 and 4.B-E and wall E4-5, 1-4 and G-H Contact Name: RA Nelson Address: 51 Eagle Road#2 City Avon State: CO ZiP; 81620 Contact Name: Grant Smith (use additional sheet if necessary) Contact Phone: 970-391-9736 Building Permits: gsmith@ranelson.com Revised ADDITIONAL Valuations(Labor 8�Materials) Contact E-Mail: (DO NOT include original valuation) I hereby acknowledge that I have read this application,filled out Building: $ in full the information required,completed an accurate plot plan, and state that all the information as required is correct. I agree to Plumbing: $ comply with the information and plot plan,to comply with all Town ordinances and state laws, and to build this structure according Electrical: $ to the town's zoning and subdivision codes, design review ap- proved,Intemational Building and Residential Codes and other Mechanical: $ ordinances of the T ap ' to. X Total: $� Owner/Owner's Repr ta' (Required) a son.com, CO ra Nel N-Cory � Date:207 Date Received: 10:00:74- , ...�, �. . . �. ... >_ � � � � l:/ � D For Ot1'ice Use Only: . �y(� Fee Paid: r`ii i� lr <� L�J�� Received From: casn Check# TOWN OF VAI L CC: vsa/MC Last 4 CC# exp.date: Authorization# �,..�� 5020 County Road 154 Gienwood Springs,CO 81601 Phone:970-945-7988 Fax:970-945-8454 HEPWORTH-PAWLAK GEOTECHNICAL hoaeo�lhos�eobech.com REINFORCEMENT STEEL INSPECTION REPORT Client: Trademark Construction Services Job No.: 112 330B Day: Thursday Attn: Brian McAndrews Date: 1/15/15 555 S. Old Woodward Ave.Suite 25L Page: 1 of 1 Birmingham, Michigan 48009 Project: Special Inspections and Construction Observation and Testing, Proposed Zekeiman Residence, Lot 5,Biock 4,Vail Viliage Third Filing,463 and 473 Beaver Dam Road�Vail, Colorado _ _..�_.____ ._�.__ _ ..__ .._ _.. Area of inspection: Walis to 10 feet below top of waii, Lines 1 to 3.5 on east side, 1 to 4 on west side, and H to B on north side _ma______._.. �_.__ ��_��._ ___.__�.__e____.______r._.,_.__ Reference Documents Structural Drawing provided on site, Sheet 312, Waii Types FW1, FVY3, 8� Used: F1N4 Inspection Notes: Reinforcing about 90% complete and inside forms not yet in place{at time of inspection. Inspection Status: � Preliminary ❑ Final � Concrete reinforcement as noted above was judged to be in reasonable conformance with the referenced construction documents. ❑ Exceptions Noted: _ _ _ __._.__ .__�_�.___.�..__.__--�_......__._ Verbal Danny with RA Nelson was informed of our inspection results. Final Communication: inspection was requested on Monday, January 19, 2015. ____ __ -- ----_ — - ---_ _---_ ..__-- - ____ _.___._._ _._-- __.__. . _ _ _ _ Distribution: Trademark Construction Services-B�ian McAndrews(brian�ltradsmarlcmi.com) R.A.Nelson 8 Associates-G�ant Smlth(�mith�anelson.com) R.A.Nelson&Associates-Danny Aldaz(daldaz@ranelson.com) Martin/Martin Engineers-Kevin Hass(KHass�martinmartln-mtn.com) Martin/Martin Engineers-Sean Molloy(smollov�martinmartin-mtn.com� Thomas J. Westhoff, CET David A. Young, P.E. Field Technician Reviewed By �...j 5020 County Road 154 � Glenwood Spriogs,CO 81601 � Phone:970-945-7988 HEPWORTH-PAWLAK GEOTECHNICAL Fax:970-945-8454 h�aeo�huneotech.com REINFORCEMENT STEEL INSPECTION REPORT Client: Trademark Construction Services Job No.: 112 330B Day: Tuesday Attn: Brian McAndrews Date: 1/20/15 555 S. Oid Woodward Ave. Suite 25L Page: 1 of 1 Birmingham, Michigan 48009 Project: Special Inspections and Construction Observation and Testing, Proposed Zekelman Residence, Lot 5, Block 4, Vail Village Third Filing, 463 and 473 Beaver Dam Road, Vail, Colorado __ __ Area of inspection: Foundation Walls to 10 feet betow top of wall, Lines 1 to 3.5 on east side, ` 1 to 4 on west side, and H to B on north side . ._ _...,_. ,�.. . __.. .. . . _.. , __ ___._..... . _ � Reference Documents Structural Drawing provided on site, Sheet 312, Wall Types FW1, FW3, 8 : Used: FW4 _ .. .,.. _._.,... : . ,_ __ _ Inspection Notes: Minor reinforcement bar clearance issues were initiaily noted and were corrected to prior to concrete placement. Inspection Status: ❑ Preliminary � Final � Concrete reinforcement as noted above was judged to be in �easonable conformance with the referenced construction documents. ❑ Exceptions Noted: ... ._ _. ... ., _ , Verbal Danny with RA Nelson was informed of our inspection results. ; Communication: Distribution: Trademark Constructlon Services-Brian McAndrews(brian�trademarkml.com) R.A.Nelsan 8�Associates-Grant Smith(s�smlth�ranelson.com) R.A. Nelson 8 Associates-Danny Aldaz(daldaz�ranelson.com) Martin/Martin Engineers-Kevin Hass(KHass�rnartinmartl�-mtn.com) Martin/Martin Engineers-Sean Molloy(amollov�martlnmartfn-mtn.coml KH Webb Architects-Stacey Gcering(stacev�khwebb.com) Thomas J. Westhoff, CET David A. Young, P.E. Field Technician Reviewed By H� 5020 Coonty Road 154 �� Glenwooc!Springs,CO 89601 Phone:970-94.�7988 Fax:970-945-8454 HEPWORTN-PAWLAK GE07ECHNICAL haaeo hps�eotech.com REINFORCEMENT STEEL INSPECTION REPORT Client: Trademark Construction Services Job No.: 112 330B Day: Friday Attn: Brian McAndrews Da#e: 2/6/7 5 555 S. Otd Woodward Ave. Suite 25L Page: 1 of 1 Birmingham, Michigan 48009 Project: Special Inspections and Construction Observation and Testing, Proposed Zekelman Residence, Lot 5� Biock 4, Vail Village Third Fi[ing, 463 and 473 Beaver Dam Road, Vail, Colorado Area of Inspection: Foundation Walls to Elevation 109� Line H, 1 to 4, 1, G to H, and 4, G to H Refe�ence Dacuments Structural Drawing provided on site, Sheet S312, S393� and S314 Used: Inspection Notes: fnspection Status: ❑ Preliminary � Final � Concrete reinforcement as noted above was judged to be 'rn reasonabte confoRnance with the referenced construction documents. ❑ Exceptions Noted: Verbal Danny with RA Nelson was informed of our inspecfion results. Communication: Distribution: Trademark Construction Services-Brian McAndrews tbrianC�trademarkmi.com) R.A.Nelson&Associates--Grant Smith(ssmith(a�ranefson.coml R.A.Nelson 8 Associates-Danny Aldaz(daldazCa�raoelson.com) Martln/Martin Engineers-Kev�n Hass(KHaas6�martinmartin-mtn.coml Martin/Martin Engineers-Sean Molloy(smollov[�martinmartin-mtn.coml KH Webb Archltects-Stacey Goering(stacev[a�khwebb.com) Thomas J.Westhoff, CET David A.Young, P.E. Field Technician Reviewed By j.�..j� 5020 Cou�ty Road 754 Glenwood Springs,CO 81601 Phone:970 945 7988 Fax:970-945-8454 HEPWORTH-PAWLAK GEOTECHNICAL hos�eo�hqs�eotech.com REINFORCEMENT STEEL INSPECTION REPORT Client: Trademark Construction Services Job No.: 112 330B Day: Tuesday Attn: Brian McAndrews Date: 2/3/15 555 S. Old Woodward Ave. Suite 25L Page: 1 of 1 Birmingham, Michigan 48009 Project: Special Inspections and Construction Observation and Testing, Proposed Zekelman Residence, Lot 5, Block 4, Vail Village Third Filing, 463 and 473 Beaver Dam Road, Vail, Colorado __ .. _ .. ___ . __. __. _ __ Area of lnspection: Foundation Walls 4, H to G and wall G, 4 to 5 and wall B, 1 to 4 and wa114, BtoEandwallE, 4to5. . .... . ........ .� ___..,... .. ._ .. __. _...... � .,...___ . ._ : _.. .,.._. . ._ : _ Reference Documents Structural plans sheets S100M, S312 Used: _ _ ..�... . .. ..__. .__ ___.___, .. �..�. __. _r N..rt_.a r.�.�,....._ . ._.. Inspection Notes: Wall H, 1 to 4 was not inspected at this time because scaffolding was not completed. Inspection Status: ❑ Preliminary � Final � Concrete reinforcement as noted above was judged to be in reasonable conformance with the referenced construction documents. ❑ Exceptions Noted: ...�._ a �._ ...._.,.��___., _.,.�,_..�.m_�_,.__�,._, :. w.... _� ,. ..�...__s ,., .,,. _._. Verbal Danny w/RA Nelson was informed that reinforcement was installed Communication: according to construction documents. _ __ - _ _ _ Distribution: __ _ _ _ Trademark Construction Services-Brian McAndrews(brlan�trademarlcmi.com) R.A Nelson 8 Associates-Grant Smith(osmlth�ranelson.com) R.A.Nelson S Associates-Danny Aidaz(daldaz�ranelaon.com) Martin/Martin Engineers-Kevin Hass(KHaas�rnartlnmartln-mtn.com) MartiNMartin Engineers-Sean Molloy(smollov�martinmartln-mtn.com) KH Webb Architects-Stacey Goering(stecev�tichwebb.com) Paul Weiser David A. Young, P.E. Field Technician Reviewed By H� 5020 County Road 154 Gienwood Springs,CO 81601 Phone:970-945-7988 Fax: 970-945-8454 HEPWORTH-PAWLAK GEOTECHNICAL �pggp�hoaeotech.COm REINFORCEMENT STEEL INSPECTION REPORT Client: Trademark Construction Services Job No.: 112 330B Day: Thursday Attn: Brian McAndrews Date: Z/5/15 555 S. Old Woodward Ave. Suite 25L Page: 1 of 1 Birmingham, Michigan 48009 Project: Special inspections and Construction Observation and Testing, Proposed Zekelman Residence, Lot 5, Block 4, Vail Village Third Filing, 463 and 473 Beaver Dam Road, Vail, Colorado Area of Inspectifln: Foundation Wall, line H, 1 to 4 was cancelled because scaffolding was still not completed. __._., _..m,_._.._,_ ,T .,__._,_ ,..,. _.. ._ .. .__. _ . .. ._...,..._._. . _r., .., .,.. _..._ Reference Documents Used: ._ .,_ .... �__�..�..__...._.�,.._._�___. �.,..�____�. ,_._..,_�_.._.�..._ .. .a..._,_ _.�_.__ ..,...._. _,._.__ �. . Inspection Notes: Inspection Status: ❑ Preliminary ❑ Final ❑ Concrete reinforcement as noted above was judged to be in reasonable conformance with the referenced construction documents. ❑ Exceptions Noted: . , . ._.._.....�..,. ___R_�._.��......��:_�._�.._w�..,�_.__. .,�__�,,.n�.._...... .��..��_._ . _ .... . . .,.._ Verbal Danny wlRA Nelson was infonned of incompleted scaffolding and that Communication: reinforcement would be inspected before concrete pour tomorrow. __ ____ _ _ ____ . ____ .,____ _ _ _ ___ _ _ __ Distribution: Trademark Construction Services-Brian McAndrews(bNan�trademarkmi.com) R.A.Nelson S Associates-Grant Smith(s�smith�ranelson.com 1 R.A.Nelson 8 Associates-Danny Aldaz(daldaz�nnelson.com) MartiNMartin Engineers-Kevin Hass(KHaas�rnartln artln-mtn.com) MartiNMartin Engineers-Sean Molloy(smollov�martlnmartin-m�.com) KH Webb Architects-Stacey Goering(stacev�lchwebb.com) Paul Weiser David A. Young, P.E. Field Technician Reviewed By