Loading...
HomeMy WebLinkAboutB15-0099 � ( � . � � 06-29-2015 Inspection Request Reporting Page 25 4�08 �m Vail,_S'O C��Of Requested Inspect Date: Tuesday,June 30,2015 Site Address: 520 LIONSHEAD MALL VAIL Lionshead Center Condo Apt 207 A/P/D Information Activity: 615-0099 Type: COMBO Sub Type: AMF Status: ISSUED Const Type: Occupancy: Use: R-2 Insp Area: Owner: LIONSHEAD CENTER CONDO APT 210 INC Applicant: HARRY W ILLIAMS Phone: 970-376-0207 Contractor: HARRY W ILLIAMS Phone: 970-376-0207 Description: Deck Enclosure Notice: Paper submittal.Scanned app to LF,routed to JS,G2-SBELLM Comment: paper submtital Load Calcs/panel routed to laserfiche and JRM-CGODFREY Reauested Inspection(s) Item: 542 PLAN-FINAL Requested Time: 08:00 AM Requestor: HARRY W ILLIAMS Phone: 970-376-0207 Comments: 376-0207 Assigned To: UT Entered By: JMONDRAGON K Action� Time Exp: Comment: Item: 90 BLDG-Final Requested Time: 09:30 AM Requestor: HARRY W ILLIAMS Phone: 970-376-0207 Comments: 376-0207 Assigned To: S Entered By: JMONDRAGON K Action: Time Exp: Comment: Item: 190 ELEC-Final Requested Time: 08:30 AM Requestor: HARRY W ILLIAMS Phone: 970-376-0207 Comments: 376-0207 Assigned To: S Entered By: JMONDRAGON K Action: Time Exp: Comment: e a g on outlet 6" Item: 290 PLMB-Final Requested Time: 09:00 AM Requestor: HARRY W ILLIAMS Phone: 970-376-0207 Comments: 376-02 Entered B JMONDRAGON K Assigned To: S R Y� Action: Time Exp: Comment: a er c ose cold reverse fi 'sh kitchen sink , � � � c (� ` � Inspection Historv �u� Item: 120 ELEC-Rough '*Approved" �� ` 05/20/15 Inspector: sgremmer Action: AP APPROVED ` f� Comment: ��� Item: 200 MECH-Rough '*Approved" � D 05/20/15 Inspector: sgremmer Action: AP APPROVED Comment: Item: 220 PLMB-Rough/D.W.V. "Approved" 05/19/15 Inspector: sgremmer Action: PI PARTIAL INSPECTION Comment: under floor DW V 05/20/15 Inspector: sgremmer Action: AP APPROVED Comment: Item: 230 PLMB-Rough/Water "Approved" 05/20l15 Inspector: sgremmer Action: AP APPROVED Comment: Item: 60 BLDG-Sheetrock Nail "`Approved`" 06/01/15 Inspector: sgremmer Action: AP APPROVED Comment: Item: 190 ELEC-Final 06/29/15 Inspector: sgremmer Action: DN DENIED Comment: max overhang on outlet 6" REPT131 Run Id: 14976 � ��-...: � :� t��� �� — / � / 06-26-2015 Inspection Request Reporting Page 19 4•17 om V�il, CD Gitv n,,i Requested Inspect Date: Monday June 29 2015 Site Address: 520 LIO�ISHEAD�IIALL VAIL Lionshead Center Condo Apt 207 A/P/D Information Activity: 615-0099 Type: COMBO Sub Type: AMF Status: ISSUED Const Type: Occup ancy: Use: R-2 Insp Area: Owner: LIONSHEAD CENTER CONDO APT 210 INC Contractor: HARRY WILLIAMS Phone: 970-376-0207 Description: Deck Enclosure Reauested Insaection(s) � Item: 542 PLAN-FINA � Requested Time: 08:15 AM Requestor: Phone: Comments: 376- 7 U Assigned To: GR Entered By: MHAEBERLE K Action: �. Time Exp: �L�p�t�9r�� �, �C�� �"� Item: 90 BLDG-Finai Requested Time: 01:00 PM Requestor: Phone: Comments: 376-0207 Assigned To: RAGON Entered By: MHAEBERLE K Action: Time Exp: �. ����� Item: 190 EL C-Final Requested Time: 10:00 AM Requestor: Phone: Comments: 376-0207 Assigned To: D AG Entered By: MHAEBERLE K Action: Time Exp: Item: 290 PLMB-Final Requested Time: 10:30 AM Requestor: Phone: Comments: 37 -0207 Assigned To: J DRAGO Entered By: MHAEBERLE K Action: � Time Exp: Item: 390 MECH-Final Requested Time: 11:00 AM Requestor: Phone: Comments: 376-0207 Assigned To: J ON Entered By: MHAEBERLE K Action: Time Exp: � ���� lC �?��J C�- ,Iy r� j -:1 ` t � ��-�� �C4 l L,� Q-e�c.�� nQ-�- �Grc� 5 T � 1 ��� � ���� � t�c�� c�`` �c�c�� �--�— ����� IP.,c��� � � � � ���,�c�• l<<`�c�G� �,�.(� �� Ins�ection Historv � Item: 120 ELEC-Rough "Approved" 05/20/15 Inspector: sgremmer Action: AP APPROVED Comment: Item: 200 MECH-Rough *"Approved*' 05/20/15 Inspector: sgremmer Action: AP APPROVED Comment: Item: 220 PLMB-Rough/D.W.V. '"Approved" 05/19/15 Inspector: s�gremmer Action: PI PARTIAL INSPECTION Comment: under floor D1NV REPT131 Run Id: 14640 Department of Community Development 75 South Frontage Road TUW� QF VA(t� � va�i, CO 81657 Tel: 970.479.2128 www.vailgov.com Development Review Coordinator TRANSM ITTAL FORM Use this form when submitting additional information for planning applications or building permits. This form is also used for requesting a revision to building permits. A two hour minimum building review fee of$110 will be charged upon reissuance of the permit. Application/Permit#(s)information applies to: Attention: o Revisions ��� `���� , �`.T..,/� R �Response to Correction Letter J /`- �attached copy of correction letter �n J I ��, �� Q�Deferred Submittal p'� oi Other Project Street Address: s� �.r�I�`�r-��� I�)r9-1� �o�� _ (Number) (Street) (Suite#) Building/Compiex Name: � l�'�t�� Description of Transmittal/List of Changes, Items Attached: Applicant Information –'" �'�!1T�� �-�`� - � �9-,�J��.-- " (architect,contractor,owner/owner's rep) Contact Name: ��� W� (�L��yY�� � Address: City State: Zip: ContaCt Name: (use additionai sheet if necessary) � —7 Contact Phone: � / � � � ' Buiiding Permits: Revised ADDITIONAL Valuations(Labor 8�Materials) Contact E-Mail: (DO NOT include original valuation) I hereby acknowledge that I have read this application,filled out Building: $ in full the information required,completed an accurate plot plan, and state that all the information as required is correct. I agree to Plumbing: $ comply with the information and plot plan,to comply with all Town ordinances and state laws, and to build this structure according Electrical: $ to the town's zoning and subdivision codes, design review ap- proved, International Building and Residential Codes and other Mechanical: $ ordinances of the Town applicable thereto. X Total: $0 Owner/Owner's Representative Signature(Required) Date Received: For Office Use Only: Fee Paid: Received From: Cash Check# CC: Visa/MC Last 4 CC# exp.date: Authorization# UNIT PANEL 207 PROJECT: LIONSHEAD CENTER ENGINEER: SOH PROJECT#: 15090 VOLTAGE: 120l208V, 1P, 3W MOUNTING: RECESSED MAINS: 100A MLO TYPE: QO RESIDENTIAL AIC: 10K PHASE PHASE DESCRIPTION A B BKR P CIR CIR P BKR A B DESCRIPTION BEDROOM REC&LTG 625 20 1 1 2 2 50 4000 RANGE DINING REC&LTG 625 20 1 3 4 4000 DISHWASHER 1000 20 1 5 6 1 20 1200 REFRIGERATOR KITCHEN CIRCUIT 1500 20 1 7 8 1 20 1200 DISPOSAL KITCHEN CIRCUIT 1500 20 1 9 10 1 20 540 BATHROOM REC(3) WASHER 1500 20 1 11 12 1 20 625 BEDROOM REC&LTG DRYER 2500 30 2 13 14 1 20 625 DEN REC&LTG 2500 15 16 0 SPACE LIVING ROOM REC&LTG 625 20 1 17 18 0 SPACE LIVING ROOM REC&LTG 625 20 1 19 20 0 SPACE SPACE 0 21 22 0 SPACE SPACE 0 23 24 0 SPACE 0 25 26 0 0 27 28 0 0 29 30 0 0 31 32 0 0 33 34 0 0 35 36 0 0 37 38 0 0 39 40 0 0 41 42 0 LOAD CALCULATION SUMMARY NOTE: PROVIDE ARC-FAULT CIRCUIT INTERRUPTER, COMBINATION-TYPE CIRCUIT BREAKERS FOR BRANCH CIRCUITS SUPPLYING ALL 120V POWER OUTLETS AS REQUIRED BY CODE �x,,,,, CALCULATED POWER FACTOR: REPLACE EXISTING PANEL WITH NEW AS SCHEDULED, RECONNECT#1 AL FEEDER ��°; : � � 1.00 PROVIDE AIC RATING AS SHOWN. �����,h��{ a '��- CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS �� `' ��"�� APPLIANCES 0 0 0 0 �._� �. - '.. LIGHTING&RECEPT. 10690 51 5692 27 �,r, ��' '� :;��`� MECHANICAL 0 0 0 0 "�� .�r t,�,�"� OVEN,WASHER, DRYER 14500 70 14500 7p �1;�;� �_�'' TOTAL 25190 121 20192 SEE DEMAND LOAD CALC 5/15/2015 LIONSHEAD CENTER UNIT 207 Demand Load Calculations (Per NEC Article 220 Parts I-Iil) Quanti Volt-Amps Demand General Dwelling unit Square footage 1250 General & Lighting (1 st 3 KVA) 1000 SF X 3 X 100% General & Lighting (Remainder) 250 SF X 3 X 35% Kitchen Small Appliances 2 EA X 1500 X 35% Refrigerator 1 EA X 1000 X 75% Dishwasher 1 EA X 1200 X 75% Oven/Range (Re:table220.19) 1 EA X 8000 X 80% Disposal 1 EA X 1000 X 75% Laundrv 8� Spa Appliances Clothes Washer 1 EA X 1000 X 75% Clothes Dryer 1 EA X 5000 X 100% Mechanical Eauipment Exhaust Fans 1 EA X 50 X 100% Add'I 25% Largest Mech. Load 1 LS X 50 X 25% TOTAL For 208V, 1-Phase, 3 Wire Service 18925 (VA) / 100 AMP SERVICE 208 = Total (VA) = 3000 - �a� � � 10 7 750 750 5000 50 13 18925 91 AMPS �i�S`�C: !tf.i �`��"li� � �� � � {* '`' �Jn n�'� ` F .v �'`� � ._. � .� y, � . + � r °r3P t�� � �. �. �-`� �rx 4�i ti •�����N���c���y�5� NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ik WORK Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B15 -0099 Project #: PRJ15 -0072 Job Address: 520 LIONSHEAD MALL VAIL Applied.....: 04/13/2015 Location......: Lionshead Center Condo Apt 207 Issued...: 04121/2015 Parcel No....: 210107103008 OWNER LIONSHEAD CENTER CONDO APT 2 04/13/2015 CIPRES NO 277 DF 06400 MEXICO, 0 APPLICANT HARRY WILLIAMS 04/13/2015 Phone: 970 - 376 -0207 1056 20 ROAD FRUITA CO 81521 License: C000003386 CONTRACTOR HARRY WILLIAMS 04 /13/2015 Phone: 970 - 376 -0207 1056 20 ROAD FRUITA CO 81521 License: C000003386 Description: Deck Enclosure Occupancy: R -2 Type Construction: IIIB Valuation: $98,500.00 rrrrrwxxwwwwwwwwrwwrrrrrxxwwrwwxrwrrrrrrxxrrwwwwwwwwxwrrrrrrrrxr .xxxrwwrwwwwwwwr. FEE SUMMARY rrrrrrxxxxr, Hxxwwwwwxwwwwrwrrrr.. xxxxwx, xwwwwwwwwwwwrr rx.r.r.rxr.exrwxwrxewww Building Permit - - -> $986.75 Bldg Plan Check - -- > $641.39 Use Tax Fee -- > $1,770.00 Electrical Permit > $57.50 Elec Plan Check – > $37.38 Restuarant Plan Review - -> $0.00 Mechanical Permit —> $60.00 Mach Plan Check - > $15.00 Additional Fees— -> $1,097.40 Plumbing Permit - -> $285.00 Plmb Plan Check - -> $71.25 Recreation Fee ---- -> $120.00 Investigation ---- ---> $0.00 Will Call -- -> $20.00 TOTAL PERMIT FEES— > $5,161.67 Payments– > $5,161.67 rrrrrrxrrrrrxwrwwwwwwwxrrrrr: rrrwwwwrxrwrrxxxrrwwwwwwwrrrrxr:: wwxwwwwwwwwwwrwrrrrrrrxwxxwrwwrrwwrrxxxrrxwwxxwwwwrxrrrxr► BALANCE DUE xxxwxwwwwrrrrrrrrrrrrrxxwwwxrwwwrxrrrrxrxxrxrrxxwwwwwxwwwwwxer -> $0.00 DECLARATIONS I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM - 4:00 PM. combination permit-012811 ww++ ww: rw++++ w++ r+ x+ rr+:: rrrrrrrrrrrrrxrrrrrrrrxxxxxrrrrwxxxw++ ww+ wrrt* w: x+t z++ rrrr:+ rrrrrrrxrxrxrrwrrwxrxxxxrrwxrrrwwxwrwrrrrrw+ w+ w+ rwr+ r+ ww++►++ r+ rrrrrr ++rrrrrrrxrrrrxrrrwwrrrxrww CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit #: B15 -0099 Address: 520 LIONSHEAD MALL VAIL Owner: LIONSHEAD CENTER CONDO APT 210 INC Location: Lionshead Center Condo Apt 207 xr+ rxxrrrrr+ xrrrxrxrrxrxrxrrxxrxrrxxrxxrrrrrrrrxrxxxrrrrrrrxrxxxrrrrrrtxrxxxrrrrrrxtxxxxrx+ rxrerwwwwrtrxrwrxrrtrrxtwrxwww+ xwrxwxxrrrxrrrwrrrrwsxrwxrwwwwwww : + + +r+ + + +ww+r +rr+xx + +rr+rr combination permit-012811 TOWN of vAIL v REQUIRED INSPECTIONS AND STATUSES Permit* B15 -0099 Address: 520 LIONSHEAD MALL VAIL Owner: LIONSHEAD CENTER CONDO APT 210 INC Location: Lionshead Center Condo Apt 207 Item: 00120 ELEC -Rough Item: 00200 MECH -Rough Item: 00220 PLMB- Rough /D.W.V. Item: 00230 PLMB- Rough/Water Item: 00240 PLMB -Gas Piping Item: 00030 BLDG - Framing Item: 00050 BLDG - Insulation Item: 00060 BLDG - Sheetrock Nail Item: 00070 BLDG -Misc. Item: 00190 ELEC -Final Item: 00290 PLMB -Final Item: 00390 MECH -Final Item: 00090 BLDG -Final Item: 00542 PLAN -FINAL combination permit-012811 Department of Community Development kr 75 South Frontage Road TOWN OF VAIL ` Vail, CO 81657 Tel: 970 -479 -2139 www.vailgov.com BUILDING PERMIT APPLICATION (Separate applications are required for alarm s &j sprinkler) Project Street Address: Project #: agnoo / "etc Z07 --�� Number DRB #: f �aL> 59 > > (Number) (Street) (Suite #) Building /Complex Name: Contractor Information Business Name: A 94-14 ,� ,q i✓I S Business Address: Z D PJ Z O 0 Building Permit #: Lot #: Block # Subdivision: I Work Class: New ( ) Addition ( ) Alteration ( ) City A State: Cn Zip: � !, Type of Building: _ .Contact Name: q^ W u , ,qy/s Single- Family ( )Duplex ( ) Multi- Family Commercial( ) Other( ) Contact Phone: n y o � Contact E -Mail: b ®�.�.A s &J u S AJ Cot � i L• C , Work Type: Interior ( ) Exterior ( ) Both (X) I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review ap- proved, International Building and Residential Codes and other ordinances of the Town applicable thereto. X Owner/Owners Re y6sentative Signature (Required) Applicant Information �{ �G, ' r Detailed Scope and Location of Work: &7-re- , Applicant Name: �l'S 11/ WV ca�,orsc��', Applicant Phone: 97D - 3 71,- - D z o 7 Applicant E -Mail: D.Au,as w cis 9 �,4� � •C ©•�^� Project Information Owner Name: Parcel #: (For Parcel #, contact Eagle County Assessors Office at (970 -328 -8640 or visit www.eaglecounty.us /patie) For Office Use Only: Fee Paid: 1 ✓ v Received From: Cash Check # CC: Visa / MC Last 4 CC # exp date: Auth # (use additional sheet if necessary) )ate eceived: D C[E °MIE _. APR 1 u 2015 TOWN OF VAIL 2014 -0901 Valuation of Work Included Plans Included Work Electrical (✓fYes ( )No ( )Yes ( )No O i Mechanical (t,,yYes ( )No ( )Yes ( )No o2, /Sa, o Plumbing ( L-JYes ( )No ( )Yes ( )No "0_10 -0b, r, Q Building (L ,)Yes ( )No ( )Yes ( )No �VV Value of all work being performed: $ 6 (value based on IBC Section 109.3 & IRC Section 108.3) Electrical Square Footage i ,�dD Applicant Information �{ �G, ' r Detailed Scope and Location of Work: &7-re- , Applicant Name: �l'S 11/ WV ca�,orsc��', Applicant Phone: 97D - 3 71,- - D z o 7 Applicant E -Mail: D.Au,as w cis 9 �,4� � •C ©•�^� Project Information Owner Name: Parcel #: (For Parcel #, contact Eagle County Assessors Office at (970 -328 -8640 or visit www.eaglecounty.us /patie) For Office Use Only: Fee Paid: 1 ✓ v Received From: Cash Check # CC: Visa / MC Last 4 CC # exp date: Auth # (use additional sheet if necessary) )ate eceived: D C[E °MIE _. APR 1 u 2015 TOWN OF VAIL 2014 -0901 r 7� "No Job Too Small" April 6, 2015 Harry Williams E -Mail: dallaswus@gmail.com Dear Harry: To follow is the load calculation for Lionshead #207: 1238 square foot x 3 watts per square feet 3,714 Small appliances 2 x 1500 watt 3,000 Electric range 8kw 8,000 No washer 0 No dryer 0 No electric heat 0 No air conditioner 0 TOTAL WATTS 14,714 Total watts 14,714 First l0k at 100% 10,000 Remaining 4,714 at 40% 1,886 TOTAL LOAD 11,886 Amp draw 11,886 watts/208 volts = 57.14 amps Existing service 100 amp 208 volts Please feel fee to contact us at 524 -5043. Sincerely: DJ /Johanna Owners P.O. Box 1221 • Gypsum, CO 81637 -1221 970 - 524 -5043 • fax 970 - 524 -5063 I Ill, ERV - dallaswus@gmail.com - Gmail Gmail COMPOSE Inbox (713) Important Sent Mail Draft (16) Categories Social (30) Promotions (339) Updates (329) Forums 60 Spruce lane (8) 207 LHC 502 LMC Junk E-mail Notes Personal Rod Flaherty Travel More skyline -ff.. R, Vendk*W FY -04VEI SpecWheartion Submittal Data Panasonic Ventilation Fan tl k6sw cei9 a al —1 E—w R—y • allsw Wtwo, provides , it—pe—tl w supply. A Attxtlas dkectPy to housg with to- ,—clity, oontml and a bda—d anoint of a apnqjs- mdeost W hl, ratan mallet pn>sstre O.otgnaA Ole h—, P— ERV shat A All Pads: 3 Years from origiral purdhwe date. I be IaWd . . bah—. only — " e nBeded for a 1,750 sq . (L 2 bed— home M nreel ale ASHRAE 62.2 -*UWn —W—. E ERV " be 08" or wag nxer0 tYTe vIm w 1bsa Mw 40 CFM w Ite ed m PM 30 CFM on tiv supply Pon, and no —, than 0.a — • —t— nm. S StadatlS a 0.1 — . — — • Power MtFQ " be 120 \,Dts and 60 1-t. g gauge. Power co—yolton shell be no greeter W,gL m" W lnwa po,,e, _Xnp0 and for heeling shag be no lass trap 66% a 30 FV-04VE1 d.—W — CFM W a flow L-W 32•F ((rQ as tested . • Motor aquqppwl w th ft—,.N W-.ff t.- arty wo CSA-C439. Tate) Floomey —tld. Effectim—1 lo, cooling shag be M leSS Den EM c_ �W 36% 9 29 CFM net air ton unda 95•F (351Q grerreYuF The supply pw damps shell dose below 20•F • Md= end ooldW w P— ih-gh • P-t proot pat. gavamzed steal body. (-7•C) to prevent fteam, of te ­ The ­ Pa-1 capillwy —e tel-10W. • Ou" 4* ff*" and eMaust ducts. shag be lowly —k..d, AC -nd— type Ths Po— &WY W 14AB • BLAR in backoraft dwTW on -h—t duct. angn—rl . — contnxtaly P— ." hr.� n9 not— ,d .,gy stay ba 120v/6011z DO din shall . — • " . Frost P—bon Mo:le pverft I. • Fa— - Supply and easel . eo-d the i— than 4'. ERV cm be used W co"* v — t— fte..V. Frost Pr—M- Mde life of the ERV — ASHRAE 62.2. LEED. LAP, Callorria Tale-24, a bw of rAeracbm and operates w0vut • E)Tendiible —ur" bra diet up to 16" on and WA Velulau- Code. O.—dion. —ft. Specifications: tallailiperCondleft FV-04VE1 40 110110 11" al 0, Eltaet N V*— (CFK 40 n 10 S-ply A, VU- (CFM1 x 20 10 03 cU WA n 21 17 sp� Ff" 1479 Im 1095 cu—t W1,90 0.15 0.10 1 0.09 Po— RNM N1144 1za60 App—t Sawittill, Bi kO H—Wng 0%930 T1111 livil 32F 0%) i TktW Raowsy Ski—Y I- C0-WV 36%929 � —T , tralakaiart Irwhuctions vtsA uLowm0ldC-cwnhwdlWW P_•.ft am alihis.— NWO T— Fb,-6-d Pl- N.—I,, KJ 07102 0'1 0- o- —wi M—) ti 0.. F 20 FW — L40— _,o Fi o o- Location: Architect: Engineer: -Contracto, Submitted by: Date: FV-04VE1 Spoictilication Subaidilliall Data Panasonic Ventilation Fan r—tinuecii ophorial Accessories Exterla VhM Cep Page I of 2 dallaswus4 ^1 in Nielsen @skylinemechar Show detail M Y https://mail.google.com/mail/u/O/?tab=wm 4/2/2015 Specifications: tallailiperCondleft FV-04VE1 40 110110 11" al 0, Eltaet N V*— (CFK 40 n 10 S-ply A, VU- (CFM1 x 20 10 03 cU WA n 21 17 sp� Ff" 1479 Im 1095 cu—t W1,90 0.15 0.10 1 0.09 Po— RNM N1144 1za60 App—t Sawittill, Bi kO H—Wng 0%930 T1111 livil 32F 0%) i TktW Raowsy Ski—Y I- C0-WV 36%929 � —T , tralakaiart Irwhuctions vtsA uLowm0ldC-cwnhwdlWW P_•.ft am alihis.— NWO T— Fb,-6-d Pl- N.—I,, KJ 07102 0'1 0- o- —wi M—) ti 0.. F 20 FW — L40— _,o Fi o o- Location: Architect: Engineer: -Contracto, Submitted by: Date: FV-04VE1 Spoictilication Subaidilliall Data Panasonic Ventilation Fan r—tinuecii ophorial Accessories Exterla VhM Cep Page I of 2 dallaswus4 ^1 in Nielsen @skylinemechar Show detail M Y https://mail.google.com/mail/u/O/?tab=wm 4/2/2015 � —T , tralakaiart Irwhuctions vtsA uLowm0ldC-cwnhwdlWW P_•.ft am alihis.— NWO T— Fb,-6-d Pl- N.—I,, KJ 07102 0'1 0- o- —wi M—) ti 0.. F 20 FW — L40— _,o Fi o o- Location: Architect: Engineer: -Contracto, Submitted by: Date: FV-04VE1 Spoictilication Subaidilliall Data Panasonic Ventilation Fan r—tinuecii ophorial Accessories Exterla VhM Cep Page I of 2 dallaswus4 ^1 in Nielsen @skylinemechar Show detail M Y https://mail.google.com/mail/u/O/?tab=wm 4/2/2015 ERV - dallaswus @gmail.com - Gmail — Idhs&04ve1 -M.. ' vantg Ear Fl/-04VE1 SpecHkation Submittal Data / Panasonic Ventilation Fan tl fisted ce&V a well rhoint Energy Reco•ery . Atta:ove dasgh usM ABS material. Venttaa provides a tw pared - sllply. • Ateo es dkecty to housing with to-nn hurnidly ,ltd, and a manned arrant of springs. exhaust to net naxan ne teal pessua 9111nraage 0srxuglou the tome. Panawnic ERV shat . AF Pads: 3,A_ ham pri ind P,.Ct_ ° data not he'nstaled n a bell—. Only one unit s The soppy Port dangler shall dose below 20-F needed fur a 1.750 sq. n. 2 badman tame to MN1b911malt yae9iraarlr meet We ASHRAE 62.2 ventllation rep+en ant. ERV st" W cabV or wad nnrrt type with no • Dual 4' intake and aghast an6. less than 40 CFM on tier exhaust port. 30 CFM 11e9ar/N**h*f: , the supply pal. and no moI ten 0.6 sae • FL*v erclosed AC caches' mdor rated for as tested n aaarderae with W 915 and 916 cortnueus run, standards at 0.1 state p *sae n aches water • Power mb g shed be 120 yaks and 60 Hz. gage. Pare, cawnPaon shall to no greeter than 23 watts Appellant SensHe Effectweress • T ho* e111a9nt bower wheels nrrag on single motor for lower pave, cormorpttn and for heatng shay be rib less than 66% at 30 . . FV -04VE7 decreased nose. CFM net air flow uncle, 32-F (0°C) as tested in 1012Y • Motor equipped with 6--1 W-,M fuse acmrderoe with CSA- C439. Total Rec—v 0.1 mod. Etactverhess for cad q VW be no less ten 36% at 29 CFM net err far under 95-F (35°Cf. iAr w� ><**irs*d*� 11nNnF The soppy Port dangler shall dose below 20-F • indoor era outdoor air passes t -gh • Rost Drool oat t glad steel body (-7-C) to Ommira tie of to core. The motor Paha4aac§ -lofty Core Woo o" • Dual 4' intake and aghast an6. shall be tot* erdnaed. AC eadsnear type Tars Process tempers simply a, whale WA aaFheaed to nn catn,ady. Pa«a r4tn9 taafeni g -istu, ad elegy. • Built in be, itraft datpa an exhaust acct. sh" be 120v/60F4. D c dar eta shell he, • Butt n Rant Prevent, Mode prenats the • Filers, sL"* and exhaust err extend fie less than 4 -. ERV ran be used to Campy with Cora fan tee-g. Fri Prshahhtan Mode Ida d the ERV core. ASHRAE 62.2. LEER. AP. Caifarne Tille -24. 9 fee d -W-1, and ape Ilse Wit" • 6Wadebhe nau bM uadtet up M 16', and WA Vantilatorn Cade ets'vMhon. cards'. n%tl30CR1 aItl 7iF10"q TaW P---y es.-0y l0r Cadeq Specifications: WldeperCemfo t FV -04VE1 Ar vd—S." 40 cm 20CM 1012Y ' -. $fate Pn*maa n 131hea ha. g. 0.1 0.1 0.1 EM Ar llatm P*4 10 20 10 it ShglPy At Vdune (CRA 30 20 10 aura (ashes( Os c03 WA powercmangltshlrMh) 23 21 1, SPa•d WSM( 1479 1292 1095 Cusrr W" O.ts 0.10 0.09 p— Wang (y/N� 12iVa0 Agparyd Sensible Ella yraasa is HWag n%tl30CR1 aItl 7iF10"q TaW P---y es.-0y l0r Cadeq 36%x29 QM ill 954 f3s-Q Fa com We ftMgalbn tetf-tims vied is.pwwde.cWWvGnMam i 030 030 - (Ftlwtl ! -- 20 rM -w3 «c _ _Sp iee3 o.ne om �-- o 10 s'0 30 w s'0 w Awhwlawl YMbi Oar1tlW tyoerwaa4t ':. P*epeh ! Location: (' Architect: '-E�- ! Contractor: St3txnitted by -_ _.__ Cale:- tire*"* Aga f*a3Y*a* MWO A-1- Pr*dhrtb OMbi*e T Rivets* Plata N*rak. NJ 07102 rfrri�w7ior rwr s`�'e�x,13�rrgd.��` .f BIdE� Iteeor'MY 1Awdtllator Specifiootian Submittal Data / Panasonic Ventilation Fan (Congaed a r Exterior WON CUP FW04VE1 Page 2 of 2 M V https: / /mail.google.com/mail/u/O /?tab —wrn 4/2/2015