Loading...
HomeMy WebLinkAboutB14-0096 Special Inspection Report Department of Community Development 75 South Frontage Road �0�� �� ���1� Vail, CO 81657 Tel: 970.479.2128 www.vailgov.com Development Review Coordinator TRANSMITTAL FORM Use this form when submitting additional information for planning applications or building permits. This form is also used for requesting a revision to building permits. A two hour minimum building review fee of$110 will be charged upon reissuance of the permit. Application/Permit#(s)information applies to: Attention: 0 Revisions Snowberry Duplex Martin Haeberle �Response to Correction Letter attached copy of correction letter Permit # 614-0096 Q Deferr S ecla�ns ection re ort �other P P P Pro'ect Street Address: 2�54 Snowberry Drive (Number) (Street) (Suite#) BuildinglComplex Name: Description of Transmittal/List of Changes, Items Attached: special inspection report: Applicant Information HP GeOteCh #HP 114017A (architect,contractor,owner/owner's rep) ' contact Name: Seth Bossung - Intention Architecture adaress: 53 Red Barn c�ty Edwards state: CO Z�p: 81632 contact Name: Seth Bossung (use additional sheet if necessary)Text Contact Phone: 970-390-0013 - Building Permits: seth@intentionarchitecture.com Revised ADDITIONAL Valuations(Labor 8�Materials) Contact E-MaiL "(DO NOT include original valuation) I hereby acknowledge that I have read this application,filled out Building: $ in full the information required,completed an accurate plot plan, and state that all the information as required is correct. I agree to Plumbing: $ comply with the information and plot plan,to comply with all Town ordinances and state laws, and to build this structure according Electrical: $ to the town's zoning and subdivision codes, design review ap- proved,International Building and Residential Codes and other Mechanical: $ ordinance of he Town applic ble thereto. X Total: $� Owner/Owner's Representativ Signature(Required) Date Received: Received For Oflice Use Only: TOWN Of VAII' By Ca�olyn Gotl/rey af 1:58 pm,Api 75,2015 Fee Paid: Received From: Cash Check# CC: Visa/MC Last 4 CC# exp.date: Authorization# West Slope Testing & Inspection LLC Report #1 3177 Glendam Dr. Grand Junction, CO 81504 Page 1 of 1 Phone: 970-434-6988 Cell: 970-260-2844 Inspection Report Date: 3-26-15 Client: HP Geotech (Job #HP 114 017A) Project: Snowberry Duplex Address: 2754 SnowberryDr. Vail, CO Buildi�g Permit No: B 14-0096 General Contractor: Slopeside Construction Inspection of shop fabrication or field work at job site: Field Report: Verified onsite welder was qualified per AWS Dl.l & using the correct welding electrodes/materials. Visually inspected field welding at steel beam, column, and steel frame connections East side unit. Note steel beam bearing on column connections were field welded two side with 1" end returns along with beam connection plates at steel frame that were welded three sides with 1/4" fillet welds in lieu of bolting, as shown on structural details. Per conversation with the structural engineer welding in lieu of bolting was acceptable & some follow up documentation would be provided. The field welding & high strength A325 bolting inspected above appeared to be in substantial conformance with the plans/engineers correspondence, and the quality requirements of the AWS D1.1 Structural Welding Code & the AISC/RCSC Specification for A325/A490 bolting. Further inspections will need to be performed on the West side unit. Dou�ias�;.Yuwng ��:ert'�catior#S1(���Z Inspector/Technician: Douglas E Young t uctur W�I a�g'�pc � i sp�� r S Ste� ' L�e�l n ' ��specrar St�ray-applied�irenrut��a �� u�!�ns[�rct�;� Douglas E Young ��I��, CWI 96070131 �� QC1 EXP. 7/1l2017