HomeMy WebLinkAboutB14-0096 CR3 Rescheck Generated by REScheck-Web Software
Compliance Certificate
Project Snowberrry Duplex
Energy Code: 2012 IECC
Location: Vail, Colorado
Construction Type: Single-family
Project Type: New Construction
orientation: Bldg. faces 333 deg. from North
Conditioned Floor Area: 11,552 ft2
Glazing Area 25%
Climate Zone: 6
Permit Date:
Permit Number:
Construction Site: Owner/Agent: Designer/Contractor:
2744 + 2754 Snowberry Lane Mike Dantas
Vail, Colorado 81657 Slopeside Construction
2121 N Frontage Rd W#206
Vail, Colorado 81657
(970) 376-5444
. . . . - .
Compliance: 17.2%Better Than Code Maximum UA: 1272 Your UA: 1053
The%Better or Worse Than Code Index reflects how dose to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Envelope Assemblies
.
. .
Ceiling - MAIN: Cathedral 2,939 38.0 21.0 0.017 50
Ceiling -SECONDARIES: Cathedral 1,939 57.0 21.0 0.013 25
Wall - E Wood: Wood Frame, 24in. o.c. 1,051 23.0 0.0 0.053 44
Orientation: Left side
Window: Vinyl Frame, 2 Pane w/Low-E 199 0.300 60
Orientation: Left side
Door: Glass 21 0.230 5
Orientation: Left side
Basement 3 E: Solid Concrete or Masonry 145 19.0 0.0 0.046 7
Orientation: Left side
Wall height: 10.0'
Depth below grade: 7.6'
Insulation depth: 10.0'
Basement 2 E: Solid Concrete or Masonry 229 19.0 0.0 0.037 8
Orientation: Left side
Wall height: 12.0'
Depth below grade: 12.0'
Insulation depth: 12.0'
Basement 1 E: Solid Concrete or Masonry 518 19.0 0.0 0.037 19
Orientation: Left side
Wall height: 12.0'
Depth below grade: 12.0'
Insulation depth: 12.0'
Project Title: Snowberrry Duplex Report date: 04/23/15
Data filename: Page 1 of10
. -
- . .
Wall - N Wood: Wood Frame, 24in. o.c. 3,965 23.0 0.0 0.053 153
Orientation: Front
Window: Vinyl Frame, 2 Pane w/Low-E 694 0.300 Z08
Orientation: Front
Door Entry: Solid 56 0.200 11
Orientation: Front
Door Garage: Solid 324 0.059 19
Orientation: Front
Wall -W Wood: Wood Frame, 24in. o.c. 774 23.0 0.0 0.053 23
Orientation: Right side
Window: Vinyl Frame, 2 Pane w/Low-E 323 0.300 97
Orientation: Right side
Door: Glass 21 0.230 5
Orientation: Right side
Basement 3 W: Solid Concrete or Masonry 148 19.0 0.0 0.039 6
Orientation: Right side
Wall height: 10.0'
Depth below grade: 10.0'
Insulation depth: 10.0'
Basement 2 W: Solid Concrete or Masonry 244 19.0 0.0 0.037 9
Orientation: Right side
Wall height: 12.0'
Depth below grade: 12.0'
Insulation depth: 12.0'
Basement 1 W: Solid Concrete or Masonry 489 19.0 0.0 0.037 18
Orientation: Right side
Wall height: 12.0'
Depth below grade: 12.0'
Insulation depth: 12.0'
Wall -5 Wood: Wood Frame, 24in. o.c. 943 23.0 0.0 0.053 29
Orientation: Back
Window: Vinyl Frame, 2 Pane w/Low-E 244 0.300 73
Orientation: Back
Door: Glass 157 0.300 47
Orientation: Back
Basement-4 5 Masters: Solid Concrete or Masonry 425 19.0 0.0 0.043 18
Orientation: Back
Wall height: 7.0'
Depth below grade: 7.0'
Insulation depth: 7.0'
Basement- 3 S: Solid Concrete or Masonry 942 19.0 0.0 0.039 37
Orientation: Back
Wall height: 10.0'
Depth below grade: 10.0'
Insulation depth: 10.0'
Basement- 2 S: Solid Concrete or Masonry 1,112 19.0 0.0 0.037 41
Orientation: Back
Wall height: 12.0'
Depth below grade: 12.0'
Insulation depth: 12.0'
Basement- 1 S: Solid Concrete or Masonry 1,112 19.0 0.0 0.037 41
Orientation: Back
Wall height: 12.0'
Depth below grade: 12.0'
Insulation depth: 12.0'
Project Title: Snowberrry Duplex Report date: 04/23/15
Data filename: Page 2 of10
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2012 IECC requirements in
REScheck Version 5.5.0 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Name-Title Signature Date
Project Notes:
Two-unit duplex, North facing, set into hillside. All buried concrete walls checked as "basement" walls. Building
checked as a single building.
Project Title: Snowberrry Duplex Report date: 04/23/15
Data filename: Page 3 of10
REScheck Software Version 5.5.0
Inspection Checklist
Energy Code: 2012 IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section Plans Verified Field Verified
# Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions
& Req.ID
103.1, Construction drawings and ❑Complies
103.2 documentation demonstrate ❑Does Not
[PR1]1 energy code compliance for the
building envelope. ❑Not Observable
- ❑Not Applicable
103.1, Construction drawings and ❑Complies
103.2, documentation demonstrate ❑Does Not
403.7 energy code compliance for
[PR311 lighting and mechanical systems. ❑Not Observable
Systems serving multiple ❑Not Applicable
� dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1, Heating and cooling equipment is Heating: Heating: ❑Complies
403.6 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not
[PR2]z on loads calculated per ACCA Coolin Coolin
Manual J or other methods g' g� ❑Not Observable
� approved by the code official. Btu/hr Btu/hr ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Snowberrry Duplex Report date: 04/23/15
Data filename: Page 4 of10
Section Plans Verified Field Verified
# Foundation Inspection Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1 Conditioned basement wall R- R- ❑Complies See the EnvelopeAssemblies
[F04]1 insulation R-value. Where interior R_ R_ ❑ table for values.
insulation is used, verification Does Not
� may need to occur during ❑Not Observable
Insulation Inspection. Not ❑Not Applicable
required in warm-humid locations
in Climate Zone 3.
303.2 Conditioned basement wall ❑Complies
[F05]1 insulation installed per ❑Does Not
manufacturer's instructions.
_ ❑Not Observable
❑Not Applicable
402.2.8 Conditioned basement wall ft ft ❑Complies see the Envelopeassemblies
[F06]1 insulation depth of burial or ❑Does Not table for values.
distance from top of wall.
_ ❑Not Observable
❑Not Applicable
303.2.1 A protective covering is installed ❑Complies
[FO11]2 to protect exposed exterior ❑Does Not
insulation and extends a
� minimum of 6 in. below grade. ❑Not Observable
❑Not Applicable
403.8 Snow-and ice-melting system ❑Complies
[F012]2 controls installed. ❑Does Not
_ ❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Snowberrry Duplex Report date: 04/23/15
Data filename: Page 5 of10
Section Plans Verified Field Verified
# Framing / Rough-In Inspection Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1, Door U-faCtor. U- U- ❑COmplie5 See the Envelope Assemblies
402.3.4 ❑DoeSNot tableforvalues.
[FR1]1 ❑Not Observable
- ❑Not Applicable
402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies
402.3.1, average). ❑DoesNot tableforvalues.
402.3.3,
402.3.6, ❑Not Observable
402.5 i ❑Not Applicable
[FR2]1 ,
303.1.3 U-factors of fenestration products ❑Complies
[FR4]1 are determined in accordance ❑Does Not
with the NFRC test procedure or
- taken from the default table. ❑Not Observable
❑Not Applicable
402.4.1.1 Air barrier and thermal barrier ❑Complies
[FR23]1 installed per manufacturer's ❑Does Not
instructions.
❑Not Observable
❑Not Applicable
402.4.3 Fenestration that is not site built ❑Complies
[FR20]1 is listed and labeled as meeting ❑Does Not
AAMA/WDMA/CSA 101/1.S.2/A440
- or has infiltration rates per NFRC ❑Not Observable
400 that do not exceed code ❑Not Applicable
limits.
402.4.4 IC-rated recessed lighting fixtures ❑Complies
[FR16]z sealed at housing/interior finish ❑Does Not
and labeled to indicate <_2.0 cfm
� leakage at 75 Pa. ❑Not Observable
❑Not Applicable
403.2.1 Supply ducts in attics are R- R- ❑Complies
[FR12]1 insulated to ?R-8.All other ducts R_ R_ ❑Does Not
in unconditioned spaces or
�� outside the building envelope are ❑Not Observable
insulated to >_R-6. ❑Not Applicable
403.2.2 All joints and seams of air ducts, ❑Complies
[FR13]1 air handlers, and filter boxes are ❑Does Not
sealed.
-�- ❑Not Observable
❑Not Applicable
403.2.3 Building cavities are not used as ❑Complies
[FR15]3 ducts or plenums. ❑Does Not
_ ❑Not Observable
❑Not Applicable
403.3 HVAC piping conveying fluids R- R- ❑Complies
[FR17]z above 105 °F or chilled fluids ❑Does Not
below 55 °F are insulated to ?R-
3 ❑Not Observable
❑Not Applicable
403.3.1 Protection of insulation on HVAC ❑Complies
[FR24]1 piping. ❑Does Not
❑Not Observable
❑Not Applicable
403.4.2 Hot water pipes are insulated to R- R- ❑Complies
[FR18]z >_R-3. ❑Does Not
❑Not Observable
❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Snowberrry Duplex Report date: 04/23/15
Data filename: Page 6 of10
Section Plans Verified Field Verified
# Framing / Rough-In Inspection Value Value Complies? Comments/Assumptions
& Req.ID
403.5 Automatic or gravity dampers are ❑Complies
[FR19]z installed on all outdoor air ❑Does Not
intakes and exhausts.
_ ❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Snowberrry Duplex Report date: 04/23/15
Data filename: Page 7 of10
Section Plans Verified Field Verified
# Insulation Inspection Value Value Complies? Comments/Assumptions
& Req.ID
303.1 All installed insulation is labeled ❑Complies
[IN13]z or the installed R-values ❑Does Not
provided.
_ ❑Not Observable
❑Not Applicable
402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies 5ee the Envelope Assemblies
402.2.5, mass wall with at least 1/z of the � Wood ❑ Wood �Does Not table for values.
402.2.6 wall insulation on the wall � Mass ❑ Mass
[IN3]1 exterior,the exterior insulation ❑Not Observable
requirement applies (FR10). ❑ Steel ❑ Steel ❑Not Applicable
303.2 Wall insulation is installed per ❑Complies
[IN4]1 manufacturer's instructions. ❑Does Not
_. ❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Snowberrry Duplex Report date: 04/23/15
Data filename: Page 8 of10
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.1, � Wood ❑ Wood �DoesNot tableforvalues.
402.2.2, � Steel ❑ Steel ❑Not Observable
402.2.6
[FI1]1 ❑Not Applicable
303.1.1.1, Ceiling insulation installed per ❑Complies
303.2 manufacturer's instructions. ❑Does Not
[F12]1 Blown insulation marked every
300 ftz. ❑Not Observable
� ❑Not Applicable
402.2.3 Vented attics with air permeable ❑Complies
[F122]z insulation include baffle adjacent ❑Does Not
to soffit and eave vents that
extends over insulation. ❑Not Observable
❑Not Applicable
402.2.4 Attic access hatch and door R- R- ❑Complies
[F13]1 insulation >_R-value of the ❑Does Not
adjacent assembly.
� ❑Not Observable
❑Not Applicable
402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies
[F117]1 ach in Climate Zones 1-2, and ❑Does Not
<=3 ach in Climate Zones 3-8.
� ❑Not Observable
❑Not Applicable
403.2.2 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies
[F14]1 cfm/100 ft2 across the system or ftz ftz ❑Does Not
<=3 cfm/100 ft2 without air
§_� ❑Not Observable
handler @ 25 Pa. For rough-in
tests, verification may need to ❑Not Applicable
occur during Framing Inspection.
403.2.2.1 Air handler leakage designated ❑Complies
[F124]1 by manufacturer at <=2%of ❑Does Not
design air flow.
❑Not Observable
❑Not Applicable
403.1.1 Programmable thermostats ❑Complies
[F19]2 installed on forced air furnaces. ❑Does Not
_ ❑Not Observable
❑Not Applicable
403.1.2 Heat pump thermostat installed ❑Complies
[FI10]z on heat pumps. ❑Does Not
. ❑Not Observable
❑Not Applicable
403.4.1 Circulating service hot water ❑Complies
[FI11]z systems have automatic or ❑Does Not
accessible manual controls.
. ❑Not Observable
❑Not Applicable
403.5.1 All mechanical ventilation system ❑Complies
[F125]z fans not part of tested and listed ❑Does Not
HVAC equipment meet efficacy
and air fiow limits. ❑Not Observable
❑Not Applicable
404.1 75%of lamps in permanent ❑Complies
[F16]1 fixtures or 75°/o of permanent ❑Does Not
fixtures have high efficacy lamps.
-�• ❑Not Observable
Does not apply to low-voltage
lighting. ❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Snowberrry Duplex Report date: 04/23/15
Data filename: Page 9 of10
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
404.1.1 Fuel gas lighting systems have ❑Complies
[F123]3 no continuous pilot light. ❑Does Not
❑Not Observable
❑Not Applicable
401.3 Compliance certificate posted. ❑Complies
[F17]z ❑Does Not
_ ❑Not Observable
❑Not Applicable
303.3 Manufacturer manuals for ❑Complies
[F118]3 mechanical and water heating ❑Does Not
systems have been provided.
_ ❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Snowberrry Duplex Report date: 04/23/15
Data filename: Page 10 of10
2012 IECC Energy
Efficiency Certificate
. .
Above-Grade Wall 23.00
Below-Grade Wall 19.00
Floor 0.00
Ceiling / Roof 59.00
Ductwork (unconditioned spaces):
� .. . .
Window 0.30
Door 0.06
. .. . . .
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments