Loading...
HomeMy WebLinkAboutB14-0096 CR3 Rescheck Generated by REScheck-Web Software Compliance Certificate Project Snowberrry Duplex Energy Code: 2012 IECC Location: Vail, Colorado Construction Type: Single-family Project Type: New Construction orientation: Bldg. faces 333 deg. from North Conditioned Floor Area: 11,552 ft2 Glazing Area 25% Climate Zone: 6 Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 2744 + 2754 Snowberry Lane Mike Dantas Vail, Colorado 81657 Slopeside Construction 2121 N Frontage Rd W#206 Vail, Colorado 81657 (970) 376-5444 . . . . - . Compliance: 17.2%Better Than Code Maximum UA: 1272 Your UA: 1053 The%Better or Worse Than Code Index reflects how dose to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies . . . Ceiling - MAIN: Cathedral 2,939 38.0 21.0 0.017 50 Ceiling -SECONDARIES: Cathedral 1,939 57.0 21.0 0.013 25 Wall - E Wood: Wood Frame, 24in. o.c. 1,051 23.0 0.0 0.053 44 Orientation: Left side Window: Vinyl Frame, 2 Pane w/Low-E 199 0.300 60 Orientation: Left side Door: Glass 21 0.230 5 Orientation: Left side Basement 3 E: Solid Concrete or Masonry 145 19.0 0.0 0.046 7 Orientation: Left side Wall height: 10.0' Depth below grade: 7.6' Insulation depth: 10.0' Basement 2 E: Solid Concrete or Masonry 229 19.0 0.0 0.037 8 Orientation: Left side Wall height: 12.0' Depth below grade: 12.0' Insulation depth: 12.0' Basement 1 E: Solid Concrete or Masonry 518 19.0 0.0 0.037 19 Orientation: Left side Wall height: 12.0' Depth below grade: 12.0' Insulation depth: 12.0' Project Title: Snowberrry Duplex Report date: 04/23/15 Data filename: Page 1 of10 . - - . . Wall - N Wood: Wood Frame, 24in. o.c. 3,965 23.0 0.0 0.053 153 Orientation: Front Window: Vinyl Frame, 2 Pane w/Low-E 694 0.300 Z08 Orientation: Front Door Entry: Solid 56 0.200 11 Orientation: Front Door Garage: Solid 324 0.059 19 Orientation: Front Wall -W Wood: Wood Frame, 24in. o.c. 774 23.0 0.0 0.053 23 Orientation: Right side Window: Vinyl Frame, 2 Pane w/Low-E 323 0.300 97 Orientation: Right side Door: Glass 21 0.230 5 Orientation: Right side Basement 3 W: Solid Concrete or Masonry 148 19.0 0.0 0.039 6 Orientation: Right side Wall height: 10.0' Depth below grade: 10.0' Insulation depth: 10.0' Basement 2 W: Solid Concrete or Masonry 244 19.0 0.0 0.037 9 Orientation: Right side Wall height: 12.0' Depth below grade: 12.0' Insulation depth: 12.0' Basement 1 W: Solid Concrete or Masonry 489 19.0 0.0 0.037 18 Orientation: Right side Wall height: 12.0' Depth below grade: 12.0' Insulation depth: 12.0' Wall -5 Wood: Wood Frame, 24in. o.c. 943 23.0 0.0 0.053 29 Orientation: Back Window: Vinyl Frame, 2 Pane w/Low-E 244 0.300 73 Orientation: Back Door: Glass 157 0.300 47 Orientation: Back Basement-4 5 Masters: Solid Concrete or Masonry 425 19.0 0.0 0.043 18 Orientation: Back Wall height: 7.0' Depth below grade: 7.0' Insulation depth: 7.0' Basement- 3 S: Solid Concrete or Masonry 942 19.0 0.0 0.039 37 Orientation: Back Wall height: 10.0' Depth below grade: 10.0' Insulation depth: 10.0' Basement- 2 S: Solid Concrete or Masonry 1,112 19.0 0.0 0.037 41 Orientation: Back Wall height: 12.0' Depth below grade: 12.0' Insulation depth: 12.0' Basement- 1 S: Solid Concrete or Masonry 1,112 19.0 0.0 0.037 41 Orientation: Back Wall height: 12.0' Depth below grade: 12.0' Insulation depth: 12.0' Project Title: Snowberrry Duplex Report date: 04/23/15 Data filename: Page 2 of10 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2012 IECC requirements in REScheck Version 5.5.0 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name-Title Signature Date Project Notes: Two-unit duplex, North facing, set into hillside. All buried concrete walls checked as "basement" walls. Building checked as a single building. Project Title: Snowberrry Duplex Report date: 04/23/15 Data filename: Page 3 of10 REScheck Software Version 5.5.0 Inspection Checklist Energy Code: 2012 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Req.ID 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate ❑Does Not [PR1]1 energy code compliance for the building envelope. ❑Not Observable - ❑Not Applicable 103.1, Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for [PR311 lighting and mechanical systems. ❑Not Observable Systems serving multiple ❑Not Applicable � dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 403.6 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]z on loads calculated per ACCA Coolin Coolin Manual J or other methods g' g� ❑Not Observable � approved by the code official. Btu/hr Btu/hr ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Snowberrry Duplex Report date: 04/23/15 Data filename: Page 4 of10 Section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1 Conditioned basement wall R- R- ❑Complies See the EnvelopeAssemblies [F04]1 insulation R-value. Where interior R_ R_ ❑ table for values. insulation is used, verification Does Not � may need to occur during ❑Not Observable Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall ❑Complies [F05]1 insulation installed per ❑Does Not manufacturer's instructions. _ ❑Not Observable ❑Not Applicable 402.2.8 Conditioned basement wall ft ft ❑Complies see the Envelopeassemblies [F06]1 insulation depth of burial or ❑Does Not table for values. distance from top of wall. _ ❑Not Observable ❑Not Applicable 303.2.1 A protective covering is installed ❑Complies [FO11]2 to protect exposed exterior ❑Does Not insulation and extends a � minimum of 6 in. below grade. ❑Not Observable ❑Not Applicable 403.8 Snow-and ice-melting system ❑Complies [F012]2 controls installed. ❑Does Not _ ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Snowberrry Duplex Report date: 04/23/15 Data filename: Page 5 of10 Section Plans Verified Field Verified # Framing / Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Door U-faCtor. U- U- ❑COmplie5 See the Envelope Assemblies 402.3.4 ❑DoeSNot tableforvalues. [FR1]1 ❑Not Observable - ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies 402.3.1, average). ❑DoesNot tableforvalues. 402.3.3, 402.3.6, ❑Not Observable 402.5 i ❑Not Applicable [FR2]1 , 303.1.3 U-factors of fenestration products ❑Complies [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or - taken from the default table. ❑Not Observable ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier ❑Complies [FR23]1 installed per manufacturer's ❑Does Not instructions. ❑Not Observable ❑Not Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/1.S.2/A440 - or has infiltration rates per NFRC ❑Not Observable 400 that do not exceed code ❑Not Applicable limits. 402.4.4 IC-rated recessed lighting fixtures ❑Complies [FR16]z sealed at housing/interior finish ❑Does Not and labeled to indicate <_2.0 cfm � leakage at 75 Pa. ❑Not Observable ❑Not Applicable 403.2.1 Supply ducts in attics are R- R- ❑Complies [FR12]1 insulated to ?R-8.All other ducts R_ R_ ❑Does Not in unconditioned spaces or �� outside the building envelope are ❑Not Observable insulated to >_R-6. ❑Not Applicable 403.2.2 All joints and seams of air ducts, ❑Complies [FR13]1 air handlers, and filter boxes are ❑Does Not sealed. -�- ❑Not Observable ❑Not Applicable 403.2.3 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not _ ❑Not Observable ❑Not Applicable 403.3 HVAC piping conveying fluids R- R- ❑Complies [FR17]z above 105 °F or chilled fluids ❑Does Not below 55 °F are insulated to ?R- 3 ❑Not Observable ❑Not Applicable 403.3.1 Protection of insulation on HVAC ❑Complies [FR24]1 piping. ❑Does Not ❑Not Observable ❑Not Applicable 403.4.2 Hot water pipes are insulated to R- R- ❑Complies [FR18]z >_R-3. ❑Does Not ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Snowberrry Duplex Report date: 04/23/15 Data filename: Page 6 of10 Section Plans Verified Field Verified # Framing / Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 403.5 Automatic or gravity dampers are ❑Complies [FR19]z installed on all outdoor air ❑Does Not intakes and exhausts. _ ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Snowberrry Duplex Report date: 04/23/15 Data filename: Page 7 of10 Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions & Req.ID 303.1 All installed insulation is labeled ❑Complies [IN13]z or the installed R-values ❑Does Not provided. _ ❑Not Observable ❑Not Applicable 402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies 5ee the Envelope Assemblies 402.2.5, mass wall with at least 1/z of the � Wood ❑ Wood �Does Not table for values. 402.2.6 wall insulation on the wall � Mass ❑ Mass [IN3]1 exterior,the exterior insulation ❑Not Observable requirement applies (FR10). ❑ Steel ❑ Steel ❑Not Applicable 303.2 Wall insulation is installed per ❑Complies [IN4]1 manufacturer's instructions. ❑Does Not _. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Snowberrry Duplex Report date: 04/23/15 Data filename: Page 8 of10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, � Wood ❑ Wood �DoesNot tableforvalues. 402.2.2, � Steel ❑ Steel ❑Not Observable 402.2.6 [FI1]1 ❑Not Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not [F12]1 Blown insulation marked every 300 ftz. ❑Not Observable � ❑Not Applicable 402.2.3 Vented attics with air permeable ❑Complies [F122]z insulation include baffle adjacent ❑Does Not to soffit and eave vents that extends over insulation. ❑Not Observable ❑Not Applicable 402.2.4 Attic access hatch and door R- R- ❑Complies [F13]1 insulation >_R-value of the ❑Does Not adjacent assembly. � ❑Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies [F117]1 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. � ❑Not Observable ❑Not Applicable 403.2.2 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [F14]1 cfm/100 ft2 across the system or ftz ftz ❑Does Not <=3 cfm/100 ft2 without air §_� ❑Not Observable handler @ 25 Pa. For rough-in tests, verification may need to ❑Not Applicable occur during Framing Inspection. 403.2.2.1 Air handler leakage designated ❑Complies [F124]1 by manufacturer at <=2%of ❑Does Not design air flow. ❑Not Observable ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies [F19]2 installed on forced air furnaces. ❑Does Not _ ❑Not Observable ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [FI10]z on heat pumps. ❑Does Not . ❑Not Observable ❑Not Applicable 403.4.1 Circulating service hot water ❑Complies [FI11]z systems have automatic or ❑Does Not accessible manual controls. . ❑Not Observable ❑Not Applicable 403.5.1 All mechanical ventilation system ❑Complies [F125]z fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy and air fiow limits. ❑Not Observable ❑Not Applicable 404.1 75%of lamps in permanent ❑Complies [F16]1 fixtures or 75°/o of permanent ❑Does Not fixtures have high efficacy lamps. -�• ❑Not Observable Does not apply to low-voltage lighting. ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Snowberrry Duplex Report date: 04/23/15 Data filename: Page 9 of10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 404.1.1 Fuel gas lighting systems have ❑Complies [F123]3 no continuous pilot light. ❑Does Not ❑Not Observable ❑Not Applicable 401.3 Compliance certificate posted. ❑Complies [F17]z ❑Does Not _ ❑Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies [F118]3 mechanical and water heating ❑Does Not systems have been provided. _ ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Snowberrry Duplex Report date: 04/23/15 Data filename: Page 10 of10 2012 IECC Energy Efficiency Certificate . . Above-Grade Wall 23.00 Below-Grade Wall 19.00 Floor 0.00 Ceiling / Roof 59.00 Ductwork (unconditioned spaces): � .. . . Window 0.30 Door 0.06 . .. . . . Heating System: Cooling System: Water Heater: Name: Date: Comments