Loading...
HomeMy WebLinkAboutAir Clearance - Timber Ridge Vail Bldg A Asbestos Consulting Services PROJECT AIR MONITORING REPORT TIMBER RIDGE APARTMENTS BUILDING A 1280 NORTH FRONTAGE ROAD WEST VAIL, COLORADO 81657 PREPARED FOR: Gorman & Company Inc. 200 North Main Street Oregon, Wisconsin 53575 Report Prepared: August 03, 2014 SEI Project Number: SEI14-P105 Prepared By: Sunrise Environmental, Inc. 371 Crest View Drive Black Hawk, Colorado 80422 Phone: 720-209-5282 www.sunrise-enviro.com EXECUTIVE SUMMARY Sunrise Environmental, Inc. provided air monitoring services for Gorman & Company, Inc. at the Timber Ridge Apartments, 1280 North Frontage Road West, Vail, Colorado July 23 –August 01, 2014. The field representative for Sunrise Environmental, Inc. was Mr. Scott D. Sanders. Work was performed in conjunction with asbestos abatement at the site. Asbestos abatement was conducted by Eco Tech Environmental Inc.; a Colorado Department of Public Health & Environment (CDPHE) licensed General Abatement Contractor (GAC). SEI’s scope of work included collection and analysis of final clearance air samples, performing a visual inspection of the work area prior to collection of air samples, and assembling project documentation. Subsequent to cleanup, Sunrise Environmental, Inc. visually inspected the containment areas for visible dust and debris. Upon passage of visual inspection, Sunrise Environmental, Inc. collected final clearance air samples and notified ETE and Gorman & Company, Inc. when laboratory results indicated airborne fiber concentrations were not in excess of 0.01f/cc as required by CDPHE Regulation No. 8. At project completion, air-monitoring results indicate concentrations of airborne fibers were not in excess of 0.01f/cc as required by the Environmental Protection Agency (EPA) and CDPHE for re-occupancy following asbestos abatement. CLIENT: Gorman & Company Inc. 200 North Main Street Oregon, Wisconsin 53575 PROJECT LOCATION: Timber Ridge Apartments 1280 North Frontage Road West Vail, Colorado 81657 Building A DESCRIPTION OF WORK: Final Visual Inspection & Final Clearance Air Monitoring ASBESTOS ABATEMENT CONTRACTORS: Eco Tech Environmental Inc. 2331 West Hampden Avenue Suite 137 Sheridan, Colorado 80110 SUNRISE ENVIRONMENTAL INC. REPRESENTATIVE: Mr. Scott D. Sanders INTRODUCTION SEI provided air monitoring services for Gorman & Company, Inc. at the Timber Ridge Apartments, 1280 North Frontage Road West, Vail, Colorado July 23 –August 01, 2014. The field representative for Sunrise Environmental, Inc. was Mr. Scott D. Sanders. Work was performed in conjunction with the removal of asbestos containing building materials at the site. Asbestos abatement was conducted by Eco Tech Environmental Inc.; a Colorado Department of Public Health and Environment (CDPHE) licensed General Abatement Contractor (GAC). Sunrise Environmental, Inc. performed the final visual inspection, and the collection and analysis of Phase Contrast Microscopy (PCM) air samples after asbestos abatement. SEI successfully participates in the AIHA Proficiency Analytical Testing (PAT) Program (Laboratory ID# 196102). All SEI analysts have been certified in NIOSH 582E to perform collection and analysis of PCM air samples. SCOPE OF WORK Eco Tech Environmental Inc.’s scope of work for this project consisted of the removal/disposal of: 1. Approximately 1,500 square feet of sheet vinyl flooring was removed from Building A. Units 1, 2, 4, 5, 6, 8, 9, 10, 11, and 12 kitchen/ dining/ entry floors (approx. 150 square feet each Unit). SEI has performed the following Industrial Hygiene services: · Performed a visual inspection of the abatement areas, · Collection and analysis of PCM air samples to monitor concentrations of airborne fibers after asbestos abatement in accordance with CDPHE Regulation No. 8, · Assembled and submitted project documentation. The findings set forth in this report are strictly limited in time and scope to the date of the evaluation. The conclusions presented in the Report are based solely on the services described therein, and not on scientific tasks or procedures beyond the scope of agreed upon services. PROJECT DESCRIPTION Sequence of field work: Table 1 summarizes the field work in the order in which it was completed. Table 1. Summary of Field Work DATE FIELD WORK 07-23-14 Pre-clearance visual inspection of Building A, Unit #1 and #2 kitchen/ Dining/ Entry containment is performed. Visual inspection passes. Collection of five (5) PCM final clearance air samples inside Building A, Unit #1 and #2 kitchen/ Dining/ Entry containment. All PCM clearance samples are analyzed and found to be below 0.01f/cc. Eco Tech Environmental Inc. on-site supervisor is notified. 07-25-14 Pre-clearance visual inspection of Building A, Unit #4, #5, #6 kitchen/ Dining/ Entry containment is performed. Visual inspection passes. Collection of five (5) PCM final clearance air samples inside Building A, Unit #4, #5, #6 kitchen/ Dining/ Entry containment. All PCM clearance samples are analyzed and found to be below 0.01f/cc. Eco Tech Environmental Inc. on-site supervisor is notified. 08-01-14 Pre-clearance visual inspection of Building A, Unit #9, #10, #11, #12 kitchen/ Dining/ Entry containment is performed. Visual inspection passes. Collection of five (5) PCM final clearance air samples inside Building A, Unit #9, #10, #11, #12 kitchen/ Dining/ Entry containment. Pre-clearance visual inspection of Building A, Unit #8 kitchen/ Dining/ Entry containment is performed. Visual inspection passes. Collection of five (5) PCM final clearance air samples inside Building A, Unit #8 kitchen/ Dining/ Entry containment. All PCM clearance samples are analyzed and found to be below 0.01f/cc. Eco Tech Environmental Inc. on-site supervisor is notified. AIR MONITORING Sample Collection The effective filter area for samples collected on July 23 through August 01, 2014 was 385mm2. PCM samples were collected on 25 millimeter (mm) mixed cellulose ester membrane filters (0.8 micron pore size). The filters were preassembled by the manufacturer. Air samples were collected at a flow rate of 15.4 to 15.7 liters per minute (LPM). Flow rates were recorded at the beginning and at the end of the sampling period using a DryCal™ Primary Standard flow calibrator. All air samples were collected open-faced and positioned at breathing zone height (approximately five feet above the floor) with exposed portion of the cassette facing downward. Clearance air samples were collected aggressively and in accordance with CDPHE Regulation #8. (See Appendix A for sample data) PCM Analysis Methodology PCM samples were analyzed by SEI according to the NIOSH 7400 Method (“A” counting rules). This method can be found in the NIOSH Manual of Analytical Methods. All air sample results are calculated with blank corrections, checked and reviewed. Unused portions of samples are archived three months unless client requests special handling. Laboratory analysis was accomplished utilizing a Phase Contrast Microscope. Size and fiber counts were performed at 400X magnification. The microscopy field area (MFA), defined by the Walton-Beckett Graticule is 0.00785mm2. Report Data Key Fbrs/Flds: Fibers per fields; total fibers counted over total areas examined. LOD: Limit of Detection; the calculated lower limit of detection expressed in fibers per cubic centimeter. Based on limit of detection of (5.5/100 fibers/field). F/cc: Fibers per cubic centimeter. <LOD: Less than the limit of Detection; thus, the analytical result is less than the value indicated in the LOD column. CONCLUSIONS At project completion, air-monitoring data indicate concentrations of airborne fibers were not in excess of 0.01f/cc as required by the Environmental Protection Agency (EPA) and CDPHE for re-occupancy following asbestos abatement. Reviewed and signed for the company by: _________________________________ Scott D. Sanders President APPENDIX A PCM AIR SAMPLE DATA SUNRISE ENVIRONMENTAL, Inc. Phase Contrast Microscopy Sampling Data Sheet PROJECT DATE: July 23, 2014 PROJECT NUMBER: SEI14-P105 CLIENT: Gorman & Company 200 North Main Street, Oregon, Wisconsin 53575 PROJECT ADDRESS: Timber Ridge Apartments 1280 North Frontage Road West, Vail, Colorado 81657 Building A, Units #1 & #2 Sample (Time) Total (Flow Rate (l/min) Total Fibers/ Number Start Stop Minutes Start Stop Avg. Volume Field LOD Fibers/cc 0723-01 --- --- --- --- --- --- --- 0/100 --- --- 0723-02 --- --- --- --- --- --- --- 0/100 --- --- 0723-03 1125 1240 75 15.6 15.6 15.6 1170. 1/100 0.002 ≤ LOD 0723-04 1125 1241 76 15.6 15.6 15.6 1186. 1/100 0.002 ≤ LOD 0723-05 1126 1242 76 15.6 15.8 15.7 1193. 0/100 0.002 ≤ LOD 0723-06 1127 1242 75 15.6 15.8 15.7 1178. 2/100 0.002 ≤ LOD 0723-07 1128 1243 75 15.6 15.8 15.8 1185. 1.5/100 0.002 ≤ LOD Sample Sample Number Type Location/Description Results 0723-01 Field Blank 0/100 0723-02 Field Blank 0/100 0723-03 CLEARANCE Bldg. A, Unit #1, kitchen, north center ≤ LOD 0723-04 CLEARANCE Bldg. A, Unit #1, kitchen, south center ≤ LOD 0723-05 CLEARANCE Bldg. A, Between Units #1 & #2 ≤ LOD 0723-06 CLEARANCE Bldg. A, Unit #2, kitchen, north center ≤ LOD 0723-07 CLEARANCE Bldg. A, Unit #2, kitchen, south center ≤ LOD LOD= Limit of Detection SUNRISE ENVIRONMENTAL, Inc. Phase Contrast Microscopy Sampling Data Sheet PROJECT DATE: July 25, 2014 PROJECT NUMBER: SEI14-P105 CLIENT: Gorman & Company 200 North Main Street, Oregon, Wisconsin 53575 PROJECT ADDRESS: Timber Ridge Apartments 1280 North Frontage Road West, Vail, Colorado 81657 Building A, Units #4, #5 & #6 Sample (Time) Total (Flow Rate (l/min) Total Fibers/ Number Start Stop Minutes Start Stop Avg. Volume Field LOD Fibers/cc 0725-01 --- --- --- --- --- --- --- 0/100 --- --- 0725-02 --- --- --- --- --- --- --- 0/100 --- --- 0725-03 1144 1301 77 15.6 15.6 15.6 1201. 1/100 0.002 ≤ LOD 0725-04 1145 1301 76 15.6 15.6 15.6 1186. 2/100 0.002 ≤ LOD 0725-05 1146 1302 76 15.6 15.4 15.5 1178. 1/100 0.002 ≤ LOD 0725-06 1147 1303 76 15.6 15.6 15.6 1186. 0/100 0.002 ≤ LOD 0725-07 1148 1304 76 15.6 15.6 15.6 1186. 3/100 0.002 ≤ LOD Sample Sample Number Type Location/Description Results 0725-01 Field Blank 0/100 0725-02 Field Blank 0/100 0725-03 CLEARANCE Bldg. A, Unit #4, Kitchen ≤ LOD 0725-04 CLEARANCE Bldg. A, Between Unit # 4 & #5 ≤ LOD 0725-05 CLEARANCE Bldg. A, Unit #5, Kitchen ≤ LOD 0725-06 CLEARANCE Bldg. A, Between Unit # 5 & #6 ≤ LOD 0725-07 CLEARANCE Bldg. A, Unit #6, Kitchen ≤ LOD LOD= Limit of Detection SUNRISE ENVIRONMENTAL, Inc. Phase Contrast Microscopy Sampling Data Sheet PROJECT DATE: August 01, 2014 PROJECT NUMBER: SEI14-P105 CLIENT: Gorman & Company 200 North Main Street, Oregon, Wisconsin 53575 PROJECT ADDRESS: Timber Ridge Apartments 1280 North Frontage Road West, Vail, Colorado 81657 Building A, Units #8, #9, #10, #11 & #12 Sample (Time) Total (Flow Rate (l/min) Total Fibers/ Number Start Stop Minutes Start Stop Avg. Volume Field LOD Fibers/cc 0801-01 --- --- --- --- --- --- --- 0/100 --- --- 0801-02 --- --- --- --- --- --- --- 0/100 --- --- 0801-03 1438 1554 76 15.6 15.8 15.7 1193. 3/100 0.002 ≤ LOD 0801-04 1439 1555 76 15.6 15.8 15.7 1193. 4.5/100 0.002 ≤ LOD 0801-05 1440 1555 75 15.6 15.6 15.6 1170. 2/100 0.002 ≤ LOD 0801-06 1140 1556 76 15.6 15.4 15.5 1178. 2/100 0.002 ≤ LOD 0801-07 1140 1556 76 15.6 15.4 15.5 1178. 3.5/100 0.002 ≤ LOD 0801-08 1458 1610 72 15.6 15.8 15.7 1130. 0/100 .002 ≤ LOD 0801-09 1458 1611 73 15.6 15.4 15.5 1132. 3/100 .002 ≤ LOD 0801-10 1459 1611 72 15.6 15.4 15.5 1116. 2/100 .002 ≤ LOD 0801-11 1500 1612 72 15.6 15.6 15.6. 1123. 1.5/100 .002 ≤ LOD 0801-12 1501 1612 71 15.6 15.2 15.4 1093. 4.5/100 .002 ≤ LOD Sample Sample Number Type Location/Description Results 0801-01 Field Blank 0/100 0801-02 Field Blank 0/100 0801-03 CLEARANCE Bldg. A, Unit #12, Kitchen ≤ LOD 0801-04 CLEARANCE Bldg. A, Unit #11, Kitchen ≤ LOD 0801-05 CLEARANCE Bldg. A, Between Units #10 & #11 ≤ LOD 0801-06 CLEARANCE Bldg. A, Unit #10, Kitchen ≤ LOD 0801-07 CLEARANCE Bldg. A, Unit #9, Kitchen ≤ LOD 0801-08 CLEARANCE Bldg. A, Unit #8, Kitchen – north ≤ LOD 0801-09 CLEARANCE Bldg. A, Unit #8, Kitchen – west ≤ LOD 0801-10 CLEARANCE Bldg. A, Unit #8, Kitchen - center ≤ LOD 0801-11 CLEARANCE Bldg. A, Unit #8, Kitchen – east ≤ LOD 0801-12 CLEARANCE Bldg. A, Unit #8, Kitchen - south ≤ LOD LOD= Limit of Detection APPENDIX B VISUAL INSPECTION FORMS APPENDIX C CERTIFICATIONS