HomeMy WebLinkAboutAir Clearance - Timber Ridge Vail Bldg A
Asbestos Consulting Services
PROJECT
AIR MONITORING REPORT
TIMBER RIDGE APARTMENTS
BUILDING A
1280 NORTH FRONTAGE ROAD WEST
VAIL, COLORADO
81657
PREPARED FOR: Gorman & Company Inc.
200 North Main Street
Oregon, Wisconsin 53575
Report Prepared: August 03, 2014
SEI Project Number: SEI14-P105
Prepared By:
Sunrise Environmental, Inc.
371 Crest View Drive
Black Hawk, Colorado 80422 Phone: 720-209-5282 www.sunrise-enviro.com
EXECUTIVE SUMMARY
Sunrise Environmental, Inc. provided air monitoring services for Gorman & Company, Inc. at
the Timber Ridge Apartments, 1280 North Frontage Road West, Vail, Colorado July 23 –August 01, 2014. The field representative for Sunrise Environmental, Inc. was Mr. Scott D. Sanders.
Work was performed in conjunction with asbestos abatement at the site. Asbestos abatement
was conducted by Eco Tech Environmental Inc.; a Colorado Department of Public Health &
Environment (CDPHE) licensed General Abatement Contractor (GAC).
SEI’s scope of work included collection and analysis of final clearance air samples, performing a
visual inspection of the work area prior to collection of air samples, and assembling project
documentation.
Subsequent to cleanup, Sunrise Environmental, Inc. visually inspected the containment areas for visible dust and debris. Upon passage of visual inspection, Sunrise Environmental, Inc. collected
final clearance air samples and notified ETE and Gorman & Company, Inc. when laboratory
results indicated airborne fiber concentrations were not in excess of 0.01f/cc as required by
CDPHE Regulation No. 8.
At project completion, air-monitoring results indicate concentrations of airborne fibers were not
in excess of 0.01f/cc as required by the Environmental Protection Agency (EPA) and CDPHE for
re-occupancy following asbestos abatement.
CLIENT: Gorman & Company Inc.
200 North Main Street
Oregon, Wisconsin 53575
PROJECT LOCATION: Timber Ridge Apartments
1280 North Frontage Road West
Vail, Colorado 81657
Building A
DESCRIPTION
OF WORK: Final Visual Inspection & Final Clearance Air Monitoring
ASBESTOS
ABATEMENT
CONTRACTORS: Eco Tech Environmental Inc.
2331 West Hampden Avenue
Suite 137 Sheridan, Colorado 80110
SUNRISE
ENVIRONMENTAL INC. REPRESENTATIVE: Mr. Scott D. Sanders
INTRODUCTION
SEI provided air monitoring services for Gorman & Company, Inc. at the Timber Ridge
Apartments, 1280 North Frontage Road West, Vail, Colorado July 23 –August 01, 2014. The
field representative for Sunrise Environmental, Inc. was Mr. Scott D. Sanders. Work was
performed in conjunction with the removal of asbestos containing building materials at the site.
Asbestos abatement was conducted by Eco Tech Environmental Inc.; a Colorado Department of Public Health and Environment (CDPHE) licensed General Abatement Contractor (GAC).
Sunrise Environmental, Inc. performed the final visual inspection, and the collection and analysis
of Phase Contrast Microscopy (PCM) air samples after asbestos abatement. SEI successfully
participates in the AIHA Proficiency Analytical Testing (PAT) Program (Laboratory ID# 196102). All SEI analysts have been certified in NIOSH 582E to perform collection and analysis
of PCM air samples.
SCOPE OF WORK
Eco Tech Environmental Inc.’s scope of work for this project consisted of the removal/disposal
of:
1. Approximately 1,500 square feet of sheet vinyl flooring was removed from Building A.
Units 1, 2, 4, 5, 6, 8, 9, 10, 11, and 12 kitchen/ dining/ entry floors (approx. 150 square feet each Unit).
SEI has performed the following Industrial Hygiene services:
· Performed a visual inspection of the abatement areas,
· Collection and analysis of PCM air samples to monitor concentrations of airborne
fibers after asbestos abatement in accordance with CDPHE Regulation No. 8,
· Assembled and submitted project documentation.
The findings set forth in this report are strictly limited in time and scope to the date of the evaluation. The conclusions presented in the Report are based solely on the services described therein, and not on scientific tasks or procedures beyond the scope of agreed upon services.
PROJECT DESCRIPTION
Sequence of field work: Table 1 summarizes the field work in the order in which it was
completed.
Table 1. Summary of Field Work
DATE FIELD WORK
07-23-14 Pre-clearance visual inspection of Building A, Unit #1 and #2 kitchen/
Dining/ Entry containment is performed. Visual inspection passes.
Collection of five (5) PCM final clearance air samples inside Building A,
Unit #1 and #2 kitchen/ Dining/ Entry containment.
All PCM clearance samples are analyzed and found to be below 0.01f/cc.
Eco Tech Environmental Inc. on-site supervisor is notified.
07-25-14 Pre-clearance visual inspection of Building A, Unit #4, #5, #6 kitchen/
Dining/ Entry containment is performed. Visual inspection passes.
Collection of five (5) PCM final clearance air samples inside Building A,
Unit #4, #5, #6 kitchen/ Dining/ Entry containment.
All PCM clearance samples are analyzed and found to be below 0.01f/cc.
Eco Tech Environmental Inc. on-site supervisor is notified.
08-01-14 Pre-clearance visual inspection of Building A, Unit #9, #10, #11, #12
kitchen/ Dining/ Entry containment is performed. Visual inspection
passes.
Collection of five (5) PCM final clearance air samples inside Building A,
Unit #9, #10, #11, #12 kitchen/ Dining/ Entry containment.
Pre-clearance visual inspection of Building A, Unit #8 kitchen/ Dining/
Entry containment is performed. Visual inspection passes.
Collection of five (5) PCM final clearance air samples inside Building A,
Unit #8 kitchen/ Dining/ Entry containment.
All PCM clearance samples are analyzed and found to be below 0.01f/cc.
Eco Tech Environmental Inc. on-site supervisor is notified.
AIR MONITORING
Sample Collection
The effective filter area for samples collected on July 23 through August 01, 2014 was 385mm2.
PCM samples were collected on 25 millimeter (mm) mixed cellulose ester membrane filters (0.8
micron pore size). The filters were preassembled by the manufacturer. Air samples were collected at a flow rate of 15.4 to 15.7 liters per minute (LPM). Flow rates were recorded at the
beginning and at the end of the sampling period using a DryCal™ Primary Standard flow
calibrator. All air samples were collected open-faced and positioned at breathing zone height
(approximately five feet above the floor) with exposed portion of the cassette facing downward.
Clearance air samples were collected aggressively and in accordance with CDPHE Regulation #8. (See Appendix A for sample data)
PCM Analysis Methodology
PCM samples were analyzed by SEI according to the NIOSH 7400 Method (“A” counting rules).
This method can be found in the NIOSH Manual of Analytical Methods. All air sample results
are calculated with blank corrections, checked and reviewed. Unused portions of samples are
archived three months unless client requests special handling. Laboratory analysis was
accomplished utilizing a Phase Contrast Microscope. Size and fiber counts were performed at 400X magnification. The microscopy field area (MFA), defined by the Walton-Beckett
Graticule is 0.00785mm2.
Report Data Key
Fbrs/Flds: Fibers per fields; total fibers counted over total areas examined. LOD: Limit of Detection; the calculated lower limit of detection expressed in fibers per
cubic centimeter. Based on limit of detection of (5.5/100 fibers/field).
F/cc: Fibers per cubic centimeter.
<LOD: Less than the limit of Detection; thus, the analytical result is less than the value
indicated in the LOD column. CONCLUSIONS
At project completion, air-monitoring data indicate concentrations of airborne fibers were not in excess of 0.01f/cc as required by the Environmental Protection Agency (EPA) and CDPHE for re-occupancy following asbestos abatement.
Reviewed and signed for the company by:
_________________________________ Scott D. Sanders President
APPENDIX A
PCM AIR SAMPLE DATA
SUNRISE ENVIRONMENTAL, Inc.
Phase Contrast Microscopy Sampling Data Sheet
PROJECT
DATE: July 23, 2014
PROJECT NUMBER: SEI14-P105
CLIENT: Gorman & Company
200 North Main Street, Oregon, Wisconsin 53575
PROJECT ADDRESS: Timber Ridge Apartments
1280 North Frontage Road West, Vail, Colorado 81657
Building A, Units #1 & #2
Sample (Time) Total (Flow Rate (l/min) Total Fibers/ Number Start Stop Minutes Start Stop Avg. Volume Field LOD Fibers/cc
0723-01 --- --- --- --- --- --- --- 0/100 --- ---
0723-02 --- --- --- --- --- --- --- 0/100 --- ---
0723-03 1125 1240 75 15.6 15.6 15.6 1170. 1/100 0.002 ≤ LOD
0723-04 1125 1241 76 15.6 15.6 15.6 1186. 1/100 0.002 ≤ LOD
0723-05 1126 1242 76 15.6 15.8 15.7 1193. 0/100 0.002 ≤ LOD
0723-06 1127 1242 75 15.6 15.8 15.7 1178. 2/100 0.002 ≤ LOD
0723-07 1128 1243 75 15.6 15.8 15.8 1185. 1.5/100 0.002 ≤ LOD
Sample Sample
Number Type Location/Description Results
0723-01 Field Blank 0/100 0723-02 Field Blank 0/100
0723-03 CLEARANCE Bldg. A, Unit #1, kitchen, north center ≤ LOD
0723-04 CLEARANCE Bldg. A, Unit #1, kitchen, south center ≤ LOD
0723-05 CLEARANCE Bldg. A, Between Units #1 & #2 ≤ LOD
0723-06 CLEARANCE Bldg. A, Unit #2, kitchen, north center ≤ LOD 0723-07 CLEARANCE Bldg. A, Unit #2, kitchen, south center ≤ LOD
LOD= Limit of Detection
SUNRISE ENVIRONMENTAL, Inc.
Phase Contrast Microscopy Sampling Data Sheet
PROJECT DATE: July 25, 2014
PROJECT NUMBER: SEI14-P105
CLIENT: Gorman & Company 200 North Main Street, Oregon, Wisconsin 53575
PROJECT
ADDRESS: Timber Ridge Apartments
1280 North Frontage Road West, Vail, Colorado 81657 Building A, Units #4, #5 & #6
Sample (Time) Total (Flow Rate (l/min) Total Fibers/
Number Start Stop Minutes Start Stop Avg. Volume Field LOD Fibers/cc
0725-01 --- --- --- --- --- --- --- 0/100 --- ---
0725-02 --- --- --- --- --- --- --- 0/100 --- ---
0725-03 1144 1301 77 15.6 15.6 15.6 1201. 1/100 0.002 ≤ LOD
0725-04 1145 1301 76 15.6 15.6 15.6 1186. 2/100 0.002 ≤ LOD
0725-05 1146 1302 76 15.6 15.4 15.5 1178. 1/100 0.002 ≤ LOD
0725-06 1147 1303 76 15.6 15.6 15.6 1186. 0/100 0.002 ≤ LOD
0725-07 1148 1304 76 15.6 15.6 15.6 1186. 3/100 0.002 ≤ LOD
Sample Sample
Number Type Location/Description Results 0725-01 Field Blank 0/100
0725-02 Field Blank 0/100
0725-03 CLEARANCE Bldg. A, Unit #4, Kitchen ≤ LOD
0725-04 CLEARANCE Bldg. A, Between Unit # 4 & #5 ≤ LOD
0725-05 CLEARANCE Bldg. A, Unit #5, Kitchen ≤ LOD 0725-06 CLEARANCE Bldg. A, Between Unit # 5 & #6 ≤ LOD
0725-07 CLEARANCE Bldg. A, Unit #6, Kitchen ≤ LOD
LOD= Limit of Detection
SUNRISE ENVIRONMENTAL, Inc.
Phase Contrast Microscopy Sampling Data Sheet
PROJECT DATE: August 01, 2014
PROJECT NUMBER: SEI14-P105
CLIENT: Gorman & Company
200 North Main Street, Oregon, Wisconsin 53575
PROJECT ADDRESS: Timber Ridge Apartments
1280 North Frontage Road West, Vail, Colorado 81657
Building A, Units #8, #9, #10, #11 & #12 Sample (Time) Total (Flow Rate (l/min) Total Fibers/ Number Start Stop Minutes Start Stop Avg. Volume Field LOD Fibers/cc 0801-01 --- --- --- --- --- --- --- 0/100 --- ---
0801-02 --- --- --- --- --- --- --- 0/100 --- ---
0801-03 1438 1554 76 15.6 15.8 15.7 1193. 3/100 0.002 ≤ LOD
0801-04 1439 1555 76 15.6 15.8 15.7 1193. 4.5/100 0.002 ≤ LOD
0801-05 1440 1555 75 15.6 15.6 15.6 1170. 2/100 0.002 ≤ LOD
0801-06 1140 1556 76 15.6 15.4 15.5 1178. 2/100 0.002 ≤ LOD
0801-07 1140 1556 76 15.6 15.4 15.5 1178. 3.5/100 0.002 ≤ LOD
0801-08 1458 1610 72 15.6 15.8 15.7 1130. 0/100 .002 ≤ LOD
0801-09 1458 1611 73 15.6 15.4 15.5 1132. 3/100 .002 ≤ LOD
0801-10 1459 1611 72 15.6 15.4 15.5 1116. 2/100 .002 ≤ LOD
0801-11 1500 1612 72 15.6 15.6 15.6. 1123. 1.5/100 .002 ≤ LOD
0801-12 1501 1612 71 15.6 15.2 15.4 1093. 4.5/100 .002 ≤ LOD
Sample Sample
Number Type Location/Description Results 0801-01 Field Blank 0/100 0801-02 Field Blank 0/100
0801-03 CLEARANCE Bldg. A, Unit #12, Kitchen ≤ LOD
0801-04 CLEARANCE Bldg. A, Unit #11, Kitchen ≤ LOD
0801-05 CLEARANCE Bldg. A, Between Units #10 & #11 ≤ LOD 0801-06 CLEARANCE Bldg. A, Unit #10, Kitchen ≤ LOD 0801-07 CLEARANCE Bldg. A, Unit #9, Kitchen ≤ LOD
0801-08 CLEARANCE Bldg. A, Unit #8, Kitchen – north ≤ LOD
0801-09 CLEARANCE Bldg. A, Unit #8, Kitchen – west ≤ LOD
0801-10 CLEARANCE Bldg. A, Unit #8, Kitchen - center ≤ LOD 0801-11 CLEARANCE Bldg. A, Unit #8, Kitchen – east ≤ LOD 0801-12 CLEARANCE Bldg. A, Unit #8, Kitchen - south ≤ LOD
LOD= Limit of Detection
APPENDIX B VISUAL INSPECTION FORMS
APPENDIX C
CERTIFICATIONS