Loading...
HomeMy WebLinkAboutB14-0042 B14-0043 B14-0044 B14-0045 REV12 plans approvedAPPROVED FOR: BIDDING PERMIT APPLICATION CONSTRUCTION PROJECT LOCATION PROJECT LOCATION SYMBOLS AND CONVENTIONS ROOM NAME 101 150 SF ROOM NAME ROOM NUMBER ROOM AREA IN SQ FEET(OPTIONAL) 999 View Name SCALE: 1/8" = 1'-0" /1 A101 1tm A101 1 1 1 1 11 11 A101 1 Ref 1 Re f 1 Ref 1 Re f 0 00 0 00 1254B 1 1tm ROOM NAME 101 150 SF Space Name 101 Volume R @ 7 1/2" 20 1tm NORTH ARROW PLAN DETAIL REFERENCE DRAWING NUMBER ON SHEET SHEET NUMBER ON WHICH DRAWING WILL BE FOUND SECTION DETAIL REFERENCE DRAWING NUMBER ON SHEET SHEET NUMBER ON WHICH DRAWING WILL BE FOUND WALL SECTION DETAIL REFERENCE DRAWING NUMBER ON SHEET SHEET NUMBER ON WHICH DRAWING WILL BE FOUND EXTERIOR ELEVATION TAG REFERENCE DRAWING NUMBER ON SHEET SHEET NUMBER ON WHICH DRAWING WILL BE FOUND INTERIOR ELEVATION TAG REFERENCE DRAWING NUMBER ON SHEET SHEET NUMBER ON WHICH DRAWING WILL BE FOUND DRAWING IDENTIFICATION DRAWING NAME DRAWING SCALE ON SHEET DRAWING NUMER SPOT ELEVATIONS ELEVATION - NEW CONSTRUCTION ELEVATION - EXISTING CONDITIONS COLUMN GRIDS COLUMN LINE LETTER OR NUMBER - NEW CONSTRUCTION COLUMN LINE LETTER OR NUMBER - EXISTING CONDITIONS ELEVATION MARKERS LEVEL BEING MARKED - NEW CONSTRUCTION LEVEL BEING MARKED - EXISTING CONDITIONS ELEVATION OF LEVEL - NEW CONSTRUCTION @ DATUM ELEVATION OF LEVEL - EXISTING CONDITIONS @ DATUM LEVEL BEING MARKED - NEW CONSTRUCTION ELEVATION OF LEVEL - NEW CONSTRUCTION @ DATUM ITEM TAGS SPACE NAME (SHOULD MATCH ROOM NAME) SPACE NUMBER (SHOULD MATCH ROOM NUMBER) SPACE VOLUME IN CUBIC FEET (OPTIONAL) ROOM TAG SPACE TAG 12 COMMON AREA DOORS (ROOM # / DOOR ID) DOOR TAGS UNIT INTERIOR DOORS WINDOW TAG - EXTERIOR / INTERIOR WALL SYSTEM TAG FLOOR SYSTEM / ROOF SYSTEM TAGS A1 SUPPLEMENTAL REFERENCE STAIR TAG -- RISER COUNT AT RISER HEIGHT REVISION TAG BATHROOM ACCESSORY TAG - SEE SCHEDULE 32im RIGID INSULATION BATT INSULATION EXISTING TO BE REMOVED IN PLAN, SECTION, OR DETAIL WOOD ROUGH WOOD FINISH MASONRY - BRICK MASONRY - CMU CONCRETE EARTH MORTAR / GROUT STEEL GRAVEL PORUS FILL LOOSE / BLOWN IN INSULATION SHEATHING GLASS SURFACE NEW WORK IN PLAN, SECTION, OR DETAIL EXISTING TO REMAIN IN PLAN, SECTION, OR DETAIL TEMPORARY WORK IN PLAN, SECTION, OR DETAIL GORMAN & COMPANY, INC. PROJECT DEVELOPER 200 NORTH MAIN STREET OREGON, WI 53575 VOICE (608) 835-3900 GORMAN & COMPANY, INC ARCHITECT OF RECORD BERGLUND ARCHITECTS, LLC DESIGN ARCHITECT P.O. BOX 2378 EDWARDS, CO 81632 VOICE: (970) 926-4301 CIVIL CONSULTANT CIVIL ALPINE ENGINEERING, INC. P.O. BOX 97 EDWARDS, CO 81632 VOICE: (970) 926-3373 STRUCTURAL ENGINEER STRUCTURAL PLUMBING MECHANICAL BEN MARSHALL, AIA 200 NORTH MAIN STREET OREGON, WI 53575 VOICE (608) 835-6339 MARTIN/MARTIN 255 MAIN STREET UNIT C101 EDWARDS, CO 81632 VOICE: (970) 926-6007 ELECTRICAL GORMAN GENERAL CONTRACTORS, LLC GENERAL CONTRACTOR R.A. NELSON & ASSOCIATES, INC. CONSTRUCTION CONSULTANT P.O. DRAWER 5400 51 EAGLE ROAD #2 AVON, CO 81620 VOICE: (970) 949-5152 200 N. MAIN STREET OREGON, WI 53575 VOICE: (608) 835-5573 PLUMBING ENGINEER BEAUDIN GANZE 222 CHAPEL PLACE UNIT AC-201 AVON, CO 81620 VOICE: (970) 949-6108 MECHANICAL ENGINEER BEAUDIN GANZE 222 CHAPEL PLACE UNIT AC-201 AVON, CO 81620 VOICE: (970) 949-6108 ELECTRICAL ENGINEER BEAUDIN GANZE 222 CHAPEL PLACE UNIT AC-201 AVON, CO 81620 VOICE: (970) 949-6108 WRIGHT & COMPANY, INC. PROJECT DEVELOPER P.O. BOX 7270 AVON, CO 81620 VOICE: (970) 748-7577 LANDSCAPING LANDSCAPE ARCHITECT DENNIS ANDERSON PO BOX 1387 EDWARDS,C O 81632 VOICE: (970) 390-3745 Sheet No. Sheet Title REAL ESTATE DEVELOPMENT & MANAGEMENT 200 N. MAIN STREET OREGON, WI 53575 Plot Date: Project No. Drawn by: Consultant Seal Issue Date: 7/8/2015 1:36:43 PM G101 PROJECT COVER LI O N ' S R I D G E A P A R T M E N T HO M E S 12 6 5 N . F r o n t a g e R o a d W e s t To w n o f V a i l , C O 8 1 6 5 7 14LION-00-01 dmk 2014.03.14 LION'S RIDGE APARTMENT HOMES 1265 NORTH FRONTAGE ROAD WEST TOWN OF VAIL, CO 81657 PROJECT DIRECTORY VICINITY MAP LOCATION MAP SHEET INDEXLEGEND NO. SHEET NAME Current Date A141 BLDG 4 F1 & F2 PLANS 2014.11.03 A142 BLDG 4 F3 & ROOF PLANS 2014.11.03 A143 BLDG 4 ELEVATIONS 2014.11.03 A144 BLDG 4 BUILDING SECTIONS 2014.04.10 A201 WINDOW ELEVATIONS & SCHEDULE 2014.11.03 A301 WALL SECTIONS 2015.03.27 A401 ENLARGED SCALE UNIT PLANS 2015.07.02 A402 ENLARGED SCALE UNIT PLANS 2015.07.02 A403 ENLARGED SCALE STAIR PLANS 2015.07.02 A501 ARCHITECTURAL DETAILS 2015.07.02 A502 ARCHITECTURAL DETAILS 2014.04.10 A503 ACCESSIBILITY NOTES & DETAILS 2015 01.20 A504 ACCESSIBILITY DETAILS 2015 01.20 A601 SCHEDULES - COMMON AREA DOORS 2014.12.15 A602 SCHEDULES - ROOM FINISHES 2014.08.04 MECHANICAL M000 MECHANICAL COVER SHEET 2014.04.10 M001 MECHANICAL SCHEDULES 2014.12.15 M100 SITE MECHANICAL PLAN 2014.04.10 M111 BLDG 1 - F1 & F2 MECHANICAL PLANS 2015 01.20 M112 BLDG 1 F3 & ROOF MECHANICAL PLANS 2014.04.10 M121 BLDG 2 F1 & F2 MECHANICAL PLANS 2015 01.20 M122 BLDG 2 F3 & ROOF MECHANICAL PLANS 2014.04.10 M131 BLDG 3 F1 & F2 MECHANICAL PLANS 2015.07.02 M132 BLDG 3 F3 & ROOF MECHANICAL PLANS 2015.07.02 M141 BLDG 4 F1 & F2 MECHANICAL PLANS 2015 01.20 M142 BLDG 4 F3 & ROOF MECHANICAL PLANS 2015.07.02 M401 UNIT MECHANICAL AND PLUMBING PLAN 2015.03.27 M402 UNIT MECHANICAL AND PLUMBING PLAN 2015.03.27 M501 MECHANICAL DIAGRAMS 2014.04.10 M502 MECHANICAL DIAGRAMS 2014.04.10 M601 W & V ISOMETRICS 2014.04.10 M602 W & V ISOMETRICS 2014.04.10 ELECTRICAL E000 ELECTRICAL COVER SHEET 2014.08.04 E001 ELECTRICAL SCHEDULES 2014.04.10 E100 SITE ELECTRICAL PLAN 2014.04.10 E111 BLDG A F1 & F2 ELECTRICAL PLANS 2014.04.10 E112 BLDG A F3 & ROOF ELECTRICAL PLANS 2014.04.10 E121 BLDG B F1 & F2 ELECTRICAL PLANS 2014.04.10 E122 BLDG B F3 & ROOF ELECTRICAL PLANS 2014.04.10 E131 BLDG C F1 & F2 ELECTRICAL PLANS 2014.04.10 E132 BLDG C F3 & ROOF ELECTRICAL PLANS 2014.04.10 E141 BLDG D F1 & F2 ELECTRICAL PLANS 2014.04.10 E142 BLDG D F3 & ROOF ELECTRICAL PLANS 2014.04.10 E401 ELECTRICAL DIAGRAM 2014.04.10 E402 ELECTRICAL DIAGRAM 2015.07.02 E501 ELECTRICAL ONE-LINE DIAGRAM 2014.04.10 E502 ELECTRICAL DIAGRAMS 2014.04.10 E503 ELECTRICAL LOAD CALCS/SCHEDULES 2014.04.10 E504 ELECTRICAL PANEL SCHEDULES 2014.04.10 E601 FIRE ALARM & COMM. DIAGRAMS 2014.04.10 NO. SHEET NAME Current Date STRUCTURAL S-001 GENERAL NOTES 2014.12.15 S-002 GENERAL NOTES 2014.08.01 S-003 QUALITY ASSURANCE NOTES 2014.08.01 S-004 QUALITY ASSURANCE NOTES 2014.11.03 S-110 BLDG 1 FOUNDATION PLAN 2014.08.01 S-111 BLDG 1 F2 PLAN 2014.12.15 S-112 BLDG 1 F3 PLAN 2014.12.15 S-113 BLDG 1 ROOF PLAN 2014.08.01 S-120 BLDG 2 FOUNDATION PLAN 2015.03.27 S-121 BLDG 2 F2 PLANS 2014.12.15 S-122 BLDG 2 F3 PLAN 2014.12.15 S-123 BLDG 2 ROOF PLAN 2014.08.01 S-130 BLDG 3 FOUNDATION PLAN 2015.03.27 S-131 BLDG 3 F2 PLAN 2014.12.15 S-132 BLDG 3 F3 PLAN 2014.12.15 S-133 BLDG 3 ROOF PLAN 2014.08.01 S-140 BLDG 4 FOUNDATION PLAN 2015.03.27 S-141 BLDG 4 F2 PLAN 2014.12.15 S-142 BLDG 4 F3 PLAN 2014.12.15 S-143 BLDG 4 ROOF PLAN 2014.08.01 S-150 ENTRY PARTIAL PLANS 2015.07.02 S-151 ENTRY ELEVATION 2014.08.01 S-152 DECK PARTIAL PLANS 2015 01.20 S-161 MAINT BLDG & DUMPSTER ENCLOSURE 2014.08.01 S-162 EXTERIOR STAIR & MONUMENT SIGNAGE 2014.08.01 S-300 CONCRETE DETAILS 2014.08.01 S-301 CONCRETE DETAILS 2014.08.01 S-302 FOUNDATION DETAILS 2015 01.20 S-303 FOUNDATION DETAILS 2014.08.01 S-400 TYP MASONRY DETAILS 2014.08.01 S-600 TYPICAL WOOD FRAMING DETAILS 2015.03.27 S-601 TYPICAL WOOD FRAMING DETAILS 2014.08.01 S-602 TYPICAL WOOD FRAMING DETAILS 2014.08.01 S-610 FLOOR DETAILS 2015.03.27 S-611 FLOOR DETAILS 2015.07.02 S-612 FLOOR DETAILS 2015.03.27 S-620 ROOF DETAILS 2014.12.15 S-621 ROOF DETAILS 2015.03.27 S-622 ROOF DETAILS 2014.08.01 S-623 ROOF DETAILS 2014.08.01 ARCHITECTURAL A111 BLDG 1 F1 & F2 PLANS 2014.11.03 A112 BLDG 1 F3 & ROOF PLANS 2014.11.03 A113 BLDG 1 ELEVATIONS 2014.11.03 A114 BLDG 1 BUILDING SECTIONS 2014.04.10 A121 BLDG 2 F1 & F2 PLANS 2014.11.03 A122 BLDG 2 F3 & ROOF PLANS 2014.11.03 A123 BLDG 2 ELEVATIONS 2014.11.03 A124 BLDG 2 BUILDING SECTIONS 2014.04.10 A131 BLDG 3 F1 & F2 PLANS 2014.12.15 A132 BLDG 3 F3 & ROOF PLANS 2014.11.03 A133 BLDG 3 ELEVATIONS 2014.11.03 A134 BLDG 3 BUILDING SECTIONS 2014.04.10 NO. SHEET NAME Current Date GENERAL G101 PROJECT COVER 2015.07.02 G102 PROJECT INFORMATION 2014.04.10 G102a BLDGS 1 & 2 EGRESS PLANS 2014.04.10 G102b BLDGS 3 & 4 EGRESS PLANS 2014.04.10 G103 BUILDING SYSTEMS 2015 01.20 SURVEY / MAPPING 1 of 5 ALTA SURVEY 2014.07.31 2 of 5 ALTA SURVEY 2014.07.31 3 of 5 ALTA SURVEY 2014.07.31 4 of 5 ALTA SURVEY 2014.07.31 5 of 5 ALTA SURVEY 2014.07.31 SITE AS101 ARCHITECTURAL SITE PLAN 2014.04.10 AS102 MAINT. BLDG & DUMPSTER ENCLOSURE 2014.04.10 AS103 EXTERIOR STAIR & MONUMENT SIGNAGE 2014.04.10 CIVIL C1.00 CIVIL COVER SHEET 2014.08.04 C1.01 EXISTING CONDITIONS PLAN 2014.08.04 C1.02 EXISTING CONDITIONS PLAN 2014.08.04 C1.03 SITE PLAN 2015.07.02 C1.04 GEOMETRIC LAYOUT AND SIGNAGE PLAN 2015.07.02 C1.05 GEOMETRIC LAYOUT AND SIGNAGE PLAN 2015.07.02 C2.01 GRADING PLAN 2015.07.02 C2.02 GRADING PLAN 2015.07.02 C2.03 SOIL NAIL WALL GEOMETRIC PLAN & PROFILE 2015.07.02 C2.04 BUILDING SECTIONS 2014.08.04 C2.05 BUILDING SECTIONS 2014.08.04 C3.01 STORM SEWER PLAN 2015.07.02 C3.02 STORM SEWER PLAN 2015.07.02 C3.03 STORM SEWER PROFILES 2015.07.02 C3.04 STORM SEWER PROFILES 2014.08.04 C4.01 UTILITY PLAN 2015.07.02 C4.02 UTILITY PLAN 2015.07.02 C4.03 UTILITY PROFILES 2014.08.04 C5.01 EROSION CONTROL PLAN 2014.08.04 C6.01 DETAILS 2014.08.04 C6.02 DETAILS 2014.08.04 C6.03 DETAILS 2014.08.04 C6.04 DETAILS 2014.08.04 C6.05 DETAILS 2014.08.04 LANDSCAPE L-1 LANDSCAPE COVER SHEET 2014.09.12 L-2 BLDG. 1 LANDSCAPE PLAN 2014.03.14 L-3 BLDG. 2 LANDSCAPE PLAN 2014.03.14 L-4 BLDG. 3 LANDSCAPE PLAN 2014.03.14 L-5 BLDG. 4 LANDSCAPE PLAN 2014.03.14 L-6 SITE LIGHTING PLAN 2014.03.14 MATERIAL LEGEND Date Issue Description 2014.04.10 2014.04.10 2014.04.10 2014.04.10 REVISION 1 REVISION 1 REVISION 1 REVISION 1 2014.08.04 2014.08.04 2014.08.04 2014.08.04 BULLETIN 1 - CONSTRUCTION SET BULLETIN 1 - CONSTRUCTION SET BULLETIN 1 - CONSTRUCTION SET BULLETIN 1 - CONSTRUCTION SET 2014.10.07 2014.10.07 2014.10.07 2014.10.07 BULLETIN 2 BULLETIN 2 BULLETIN 2 BULLETIN 2 2014.11.03 2014.11.03 2014.11.03 2014.11.03 BULLETIN 3 BULLETIN 3 BULLETIN 3 BULLETIN 3 2014.12.15 2014.12.15 2014.12.15 2014.12.15 BULLETIN 4 BULLETIN 4 BULLETIN 4 BULLETIN 4 2015 01.20 2015 01.20 2015 01.20 2015 01.20 BULLETIN 5 BULLETIN 5 BULLETIN 5 BULLETIN 5 2015.03.27 2015.03.27 2015.03.27 2015.03.27 BULLETIN 6 BULLETIN 6 BULLETIN 6 BULLETIN 6 2015.07.02 2015.07.02 2015.07.02 2015.07.02 BULLETIN 7 BULLETIN 7 BULLETIN 7 BULLETIN 7 7 7 7 7 7 7 7 7 7 7 S-151 1 STEP T/FTG C7 C7C9C9C9C94S-302TYP 6 S-302TYP1 3/4" SLAB RECESS UP3S-303C14C14TO ROOF TO ROOF 11 1/4 LVL STAIR STRINGER @ 16" oc8S-302 SEE PLAN FOR FOOTING STEP FOR PLUMBING 6 S-3022S-30212S-3011S-302 12 S-303 8" TYP 8" TYP 8"3 S-303SIMW5-B6 W5-B6 W5-B6 W5-B6 (2) 2x4 W/(2) 2x4 KINGS(2) 2x4 W/(2) 2x4 KINGS(2) 2x4 W/(2) 2x4 KINGS (2) 2x4 W/(2) 2x4 KINGS (2) 2x4 W/(2) 2x4 KINGS(2) 2x4 W/(2) 2x4 KINGS(2) 2x4 W/(2) 2x4 KINGS (2) 2x4 W/(2) 2x4 KINGS W5-A8 W5-A8W5-A8 W5-A8 W5-A8 W5-A8 S- 1 5 1 1 OP E N 5/ 4 " T R E X W 5 - A 3 W 5 - A 3 W 5 - A 3 W 5 - A 3 C7 C7 H 9 - 1 1 6 x 1 2 6 x 1 2 H5 - 3 2 6 S- 6 2 0 1 S- 6 2 2 3 S- 6 2 2 2 S- 6 2 2 TY P TY P 6 S- 6 1 0 TY P 2 x 8 @ 1 6 " O C 2 x 8 @ 1 6 " O C 3x 1 2 @ 2 4 " O C 4x 1 2 4x 1 2 4 x 1 2 4x 1 2 4 x 1 2 4 x 1 2 4 x 1 2 4 x 1 2 DN T/ D E C K SE E P L A N SL O P E 3" / 1 2 " 5/ 4 " T R E X 5/ 4 " T R E X UP H 9 - 1 1 H 9 - 1 1 H 9 - 1 1 H 9 - 1 1 H 9 - 1 1 H 9 - 1 1 H 9 - 1 1 4 x 1 4 S T A I R S T R I N G E R @ 1 6 " O C W S 1 6 S- 6 1 0 3 S- 6 1 0 5 S- 6 1 2 1 S- 6 1 0 11 S- 6 1 1 5 S- 6 1 0 4x 1 2 5/ 4 " T R E X 2 x 8 @ 1 6 " O C 2 x 8 @ 1 6 " O C 2 x 8 @ 1 6 " O C 2 x 8 @ 1 6 " O C 4 x 1 2 4x 1 2 (2 ) 2 x 4 W / (2 ) 2 x 4 K I N G S (2 ) 2 x 4 W / (2 ) 2 x 4 K I N G S (2 ) 2 x 4 W / (2 ) 2 x 4 K I N G S (2 ) 2 x 4 W / (2 ) 2 x 4 K I N G S (2 ) 2 x 4 W / (2 ) 2 x 4 K I N G S (2 ) 2 x 4 W / (2 ) 2 x 4 K I N G S (2 ) 2 x 4 W / (2 ) 2 x 4 K I N G S (2 ) 2 x 4 W / (2 ) 2 x 4 K I N G S 12 S- 6 1 1 H 9 - 1 1 H 9 - 1 1 C7 C7 W 5 - A 1 W 5 - A 1 W 5 - A 1 W 5 - A 1 5/ 4 " T R E X 6 S- 6 1 0 TY P 2 x 8 @ 1 6 " O C 2 x 8 @ 1 6 " O C 4x 1 2 4x 1 2 4 x 1 2 4 x 1 2 4 x 1 2 4 x 1 2 4 x 1 2 4 x 1 2 4x 1 2 UP OP E N T/ D E C K SE E P L A N 5/ 4 " T R E X 5/ 4 " T R E X DN H 9 - 1 1 H 9 - 1 1 H 9 - 1 1 H 9 - 1 1 H 9 - 1 1 H 9 - 1 1 4 x 1 4 S T A I R S T R I N G E R @ 1 6 " O C 6 S- 6 1 0 5 S- 6 1 2 3 S- 6 1 0 5 S- 6 1 2 1 S- 6 1 0 11 S- 6 1 1 SI M 11 S- 6 1 1 5 S- 6 1 0 5/ 4 " T R E X 2 x 8 @ 1 6 " O C 2 x 8 @ 1 6 " O C 2 x 8 @ 1 6 " O C 2 x 8 @ 1 6 " O C 4x 1 2 4x 1 2 12 S- 6 1 1 S- 1 5 1 1 H 9 - 1 1 H 9 - 1 1 H 9 - 1 1 C7 C7 GI R D E R T R U S S 9 S- 6 2 0 H 9 - 1 1 H 9 - 1 1 H 9 - 1 1 H 9 - 1 1 H 9 - 1 1 WS 1 P R E - E N G I N E E R E D R O O F T R U S S @ 2 4 " O C P R E - E N G I N E E R E D R O O F T R U S S @ 2 4 " O C WS 1 22 " x 4 8 " A T T I C A C C E S S CO O R D I N A T E L O C A T I O N WI T H T R U S S B O T T O M CH O R D S P A C I N G (2 ) 2 x 6 EA C H SI D E 8 S- 6 2 0 3 S- 6 2 0 11 S- 6 2 0 Sheet  No.Sheet  TitleDCBA1 2 3 4 5 D C B A 1 2 3 4 5 REAL  ESTATE DEVELOPMENT  &MANAGEMENT 200  N. MAIN  STREET OREGON, WI  53575 Plot  Date:Project  No.Drawn  by:ConsultantSeal 03.14.14 BID  AND  BUILDING  PERMIT 08.01.14 CONSTRUCTION  SETDATE ISSUE  AND  DESCRIPTION7/3/2015  3:08:30  PM S ‐150ENTRY PARTIAL  PLANSLION'S RIDGE APARTMENT HOMES 1280 N. Frontage Road West Town of Vail, CO 81657 13.0870.S01 KJG/SJM 1/4" = 1'-0"1 ENTRY FND PARTIAL PLAN 1 / 4 " = 1 ' - 0 " 2 EN T R Y 2 N D F L P A R T I A L P L A N 1 / 4 " = 1 ' - 0 " 3 EN T R Y 3 R D F L P A R T I A L P L A N 1 / 4 " = 1 ' - 0 " 4 EN T R Y R O O F P A R T I A L P L A N SE E P L A N F O R O R I E N T A T I O N SE E P L A N F O R O R I E N T A T I O N SE E P L A N F O R O R I E N T A T I O N SEE PLAN FOR ORIENTATION304.10.14 REVISION  1 11.03.14 BULLETIN  #3 12.15.14 BULLETIN  #4 03.27.15 BULLETIN  #6 07.02.15 BULLETIN  #77/6/2015 FULL HEIGHT 2x BLOCKING, TYP2x LEDGER W/ (3) #14x3"SCREWS AT 16" OC SIMPSON H2.5A EACH SIDE OF RAFTERSIMPSON HU9 AT LVL 2x LEDGER W/(2) #14 SCREWS @ 16" OC 2x BLOCKING @ 48" OC S-6116S-6114S-6115 6x8 POST AT BRACKET S-30312 SIM 2x 8 L E D G E R w / ( 2 ) RO W S # 1 2 x 3 " SC R E W S @ 1 2 " O C 2/ S - 6 1 0 FO R A D D I T I O N A L IN F O S E E BL O C K I N G w / S H E A R WA L L C O N N E C T I O N PE R PR O V I D E T R U S S V E R T I C A L AT B E A R I N G W A L L 2/ S - 6 1 0 S- 6 1 0 11 AT 3 R D F L O O R O N L Y 3 "2 " 1 '-7 "1 0 " PL 1 / 4 x 4 " H D G w / (2 ) 3 / 4 " Ø B O L T S PL 3 / 8 x 6 x 1 ' - 6 " H D G w / ( 4 ) 3/ 8 " Ø T H R U B O L T S . CO U N T E R S I N K I N P O S T 3/ 1 6 3/ 1 6 A A (3 ) # 1 4 S C R E W S @ 1 6 " O C AT L E D G E R T O R I M B O A R D SI M P S O N U 3 1 0 H A N G E R A T 3x 1 2 R A F T E R T O L E D G E R SI M P S O N D T T 2 Z w / 1/ 2 " Ø T H R E A D E D R O D AT B R A C K E T C O N N FU L L H E I G H T 2 x B L O C K I N G CO N T I N U E 8 ' - 0 " F R O M W A L L AT B R A C K E T C O N N (3 ) S I M P S O N M S T A 1 5 ST R A P A T B L O C K I N G , T Y P 2 " 6 " 7 " 3 1 /4 " 2 " SI M P S O N H G A 1 0 E A C H SI D E A T B R A C K E T (2 ) 1 / 4 x 5 x 1 ' - 3 " P L A T E S H D G , W / (2 ) 1 " Ø T H R U B O L T S A T BR A C K E T K I C K E R 3/ 1 6 3/ 1 6 HD G AS S E M B L Y AF T E R WE L D I N G PL 1 / 4 x x 0 ' - 1 1 " H D G , w/ ( 2 ) 1 " Ø T H R U B O L T S 2x B L O C K I N G 8d @ 6 " O C @ B L O C K I N G & P A N E L E D G E S SI M P S O N H U C 2 6 - 3 SI M P S O N C C Q 5 - 6 S D S 2 . 5 W/ N O T C H @ P O S T SI M P S O N M S T C 4 0 AT P S L P O S T , T Y P SI M P S O N HU 6 1 2 A T L O W RO O F B M , T Y P SI M P S O N H U C 2 6 - 3 SI M P S O N MS T C 4 0 (2 ) 3 / 4 " Ø B O L T S W / 2" Ø P L W A S E R S SI M P S O N L S T A 2 1 w / ( 8 ) 10 d N A I L S A T B L O C K I N G AN D ( 8 ) 1 0 d N A I L S A T B M RA I L I N G P O S T , S E E A R C H 2 1 / 2 " 6 " 2 1 / 2 " (6 ) 1 2 d T O E N A I L S A T BL O C K I N G T O P A R A L L E L JO I S T S (2 ) S I M P S O N L S C @ E A S T R I N G E R ST A I R B E A M TR E X D E C K I N G Sheet  No.Sheet  TitleDCBA1 2 3 4 5 D C B A 1 2 3 4 5 REAL  ESTATE DEVELOPMENT  &MANAGEMENT 200  N. MAIN  STREET OREGON, WI  53575 Plot  Date:Project  No.Drawn  by:ConsultantSeal 03.14.14 BID  AND  BUILDING  PERMIT 08.01.14 CONSTRUCTION  SETDATE ISSUE  AND  DESCRIPTION7/3/2015  3:08:31  PM S ‐611FLOOR DETAILSLION'S RIDGE APARTMENT HOMES 1280 N. Frontage Road West Town of Vail, CO 81657 13.0870.S01 Author 1 1/2" = 1'-0"1 STORAGE EAVE AND LEDGER PERP TO WALL 1 1/2" = 1'-0"2 STORAGE ROOF LEDGER PARALLEL TO WALL 3/8" = 1'-0"3 BRACKET SECTION 1 1 / 2 " = 1 ' - 0 " 7 LE D G E R A T D E C K 1 1 / 2 " = 1 ' - 0 " 8 TR U S S B E A R I N G A T S T O R A G E W A L L 1 1 / 2 " = 1 ' - 0 " 6 BR A C K E T C O N N E C T I O N A T P O S T 1 " = 1 ' - 0 " 4 BR A C K E T C O N N A T F L O O R 1 1 / 2 " = 1 ' - 0 " 5 BR A C K E T C O N N A T B E A M 1 / 2 " = 1 ' - 0 " 9 EN T R Y W I N D O W C O N N 1 " = 1 ' - 0 " 10 EN T R Y W I N D O W C O N N 2 1 1 / 2 " = 1 ' - 0 " 11 HA N D R A I L C O N N A T S T A I R L A N D I N G 04.10.14 REVISION  1 03.27.15 BULLETIN  #6 07.02.15 BULLETIN  #7 1 1 / 2 " = 1 ' - 0 " 12 ST A I R S T R I N G E R C O N N 7/6/2015 E4 A401 3 2 X3'-0" 7'-0" X 3' - 0 " 8' - 0 " X3'-0" 7'-0" 2 0 DOOR ID VARIES BY BLDG & FLOOR DO O R I D V A R I E S BY B L D G & F L O O R BEDROOM LIVING / DINING AREA KITCHEN UTILITIES BATH CLOSET PATIO STORAGE REFR RA N G E DW WH AH U W/D DOOR ID VARIES BY BLDG & FLOOR 21 ' - 0 1 / 4 " 9' - 1 1 3 / 4 " - 8' - 0 " 6' - 1 0 1 / 4 " 3' - 1 1 / 2 " 1' - 1 0 " 9' - 2 1 / 2 " 10 ' - 9 " - 2' - 2 " 5 1 / 2 " 7' - 4 1 / 4 " 5'-0" 11'-6" 23'-7" 11'-7" -5'-9" -5'-8" AP01 AP07 AP11 AP 0 2 X5'-0" 7'-0" 11'-7" -11'-8 1/2" CO A T 12 " S H & R 16" SH & R (5) 16" SH VS 6 D 4 8 B MODULAR TUB SURROUND 5'-0" W4 W3 W2 W3 W4 W4A W1A W5 W4 W4 ALL PATIO RAILS 42" A.F.F MW / H O O D PATIO VARIES BY FLOOR E4 10 ' - 8 1 / 2 " - 10 ' - 0 1 / 4 " 21 ' - 0 1 / 4 " 2' - 6 " 5 1 / 2 " 7' - 4 1 / 4 " 7' - 4 1 / 2 " - 13 ' - 4 1 / 4 " 8' - 6 " BEDROOM LIVING / DINING AREA KITCHEN UTILITIES BATH COATS PATIO STORAGE REFR DW RA N G E X 3' - 0 " 8' - 0 " X3'-0" 7'-0" 01 A401 5 6 AH U WH W/D 6' - 1 0 1 / 4 " - 1' - 1 0 " 3' - 6 1 / 2 " DOOR ID VARIES BY BLDG &FLOOR DO O R I D V A R I E S BY B L D G & F L O O R ALL PATIO RAILS 42" A.F.F AP 0 2 AP01 AP 0 7 AP11 AP11 8' - 0 " 5'-0" 12'-6 1/2" 2'-9 1/2" - CL O S E T 16 " S H & R 12" SH & R 11'-7" -5'-9" -5'-8" 23'-7" 3'-9" X3'-0" 7'-0" MODULAR TUB SURROUND MW / H O O D VS 6 D 4 8 B PATIO VARIES BY FLOOR E4 20 ' - 9 1 / 4 " MASTER BEDROOM WIC MASTER BATH BATH COATS BEDROOM LIVING / DINING AREA KITCHEN UTILITIES PATIO STORAGE DW RA N G E WH AH U W/D REFR 0 3 32X 3' - 0 " 8' - 0 " X3'-0" 7'-0" 33'-8" DOOR ID VARIES BY BLDG & FLOOR DO O R I D V A R I E S BY B L D G & F L O O R ALL PATIO RAILS 42" A.F.F A401 9 8 DOOR ID VARIES BY BLDG & FLOOR W5 W1A W2 10'-10 1/2" -9'-10" -2'-4 1/2" 10'-0" 5' - 6 1 / 4 " - 2' - 1 0 " 1' - 6 " 10 ' - 7 1 / 2 " 23 ' - 1 0 1 / 4 " 11'-2 1/2" -5'-9" -5'-8" -10'-2" AP 0 1 AP01 AP 1 3 AP 0 2 AP 0 2 AP11 X 5' - 0 " 7' - 0 " 10 ' - 7 1 / 2 " - 4' - 0 1 / 2 " 8' - 1 0 1 / 4 " - 2' - 8 " 9' - 2 1 / 2 " 3'-9" W4 W4 W4 W4 W4 W3 W3 W3 W4 W4 W4 W4A W4 7' - 3 3 / 4 " 5 1 / 2 " 2' - 1 " - 3' - 9 " 3 1 / 2 " 9' - 8 " 8' - 0 " X3'-0" 7'-0" CL O S E T MODULAR TUB SURROUND MO D U L A R T U B SU R R O U N D MW / H O O D VS 6 D 4 8 B VS6D48B PATIO VARIES BY FLOOR 7 7 E4 8' - 6 " KITCHEN LIVING / DINING AREA BEDROOM MASTER BEDROOM MASTER BATH WIC BATH UTILITIES COATS PATIO STORAGE REFR DW RA N G E AH U W/D WH 33'-8" X3'-0" 7'-0" X3'-0" 7'-0" X 3' - 0 " 8' - 0 " 33 1 1 DOOR ID VARIES BY BLDG & FLOOR DOOR ID VARIES BY BLDG & FLOOR DO O R I D V A R I E S BY B L D G & F L O O R A401 12 11 11'-2 1/2" -5'-9" -5'-8" -10'-2" 9' - 1 0 1 / 4 " 3' - 6 1 / 2 " 1' - 1 0 " - 6' - 1 0 1 / 4 " 9' - 8 " - 3'-9" 3' - 8 1 / 2 " - 5' - 8 " 21 ' - 0 1 / 4 " AP 0 2 AP 1 3 AP11 AP 0 1 AP 0 2 AP01 W4 W4 W4 W4 W4 W4 W4 W3 W3 W3 W4A W4 W4 W4 3' - 9 " - 2' - 6 1 / 2 " 7' - 3 3 / 4 " 8'-0 1/2" 4'-1" -11'-11 1/2" -2'-1" -10'-4 1/2" 10 ' - 1 0 1 / 2 " - 4' - 0 1 / 2 " - 5' - 6 1 / 4 " 8' - 0 " 5'-0" ALL PATIO RAILS 42" A.F.F CL O S E T MODULAR TUB SURROUND MO D U L A R T U B SU R R O U N D W2 W5 W5 W1A MW / H O O D VS 6 D 4 8 B VS6D48B PATIO VARIES BY FLOOR FILLER AS REQ'D FILLER AS REQ'D UNIT ENTRY DOOR W3012 MW / HOOD W1530 W2 4 3 0 W361524 W2430 DW SS SINK W/ SINGLE LEVER FAUCET PLAM COUNTERTOP SLIDE-IN RANGE / OVEN B4D15 SL S 3 6 AP07 FILLER AS REQ'D W2430 W3918 W2430 W3012 SL S 3 6 SB39 DW W361524 REFR PLAM COUNTERTOP SS SINK W/ SINGLE LEVER FAUCET MW / HOOD SLIDE-IN RANGE / OVEN 84 " 36 " 18 " W1530 W3012 W2430 W361524 MW / HOOD SLIDE-IN RANGE / OVEN PLAM SL S 3 6 B4D15 FILLER AS REQ'D 36 " 18 " 30 " 7' - 0 " UNIT ENTRY DOOR SS SINK W/ SINGLE LEVER FAUCET PLAM COUNTERTOP W2430 W3918 W2430 W361524 REFR DW SS SINK W/ SINGLE LEVER FAUCET SB39 SLIDE-IN RANGE / OVEN SL S 3 6 PLAM COUNTERTOP MW / HOOD W3012 FILLER AS REQ'D 30 " 18 " 36 " 7' - 0 " W2430 W3930 W3012 SLIDE-IN RANGE / OVEN MW / HOOD B4D15 PLAM COUNTERTOP SL S 3 6 SS SINK W/ SINGLE LEVER FAUCET DW FILLER AS REQ'D 30 " 18 " 36 " 7' - 0 " UNIT ENTRY DOOR W2430 B24 W361524 W2430 W3618 W2430 W3012 MW / HOOD SLIDE-IN RANGE / OVEN PLAM COUNTERTOP SL S 3 6 SB36 SS SINK W/ SINGLE LEVER FAUCET DW REFR FILLER AS REQ'D 36 " 18 " 30 " 7' - 0 " W1530 W3012 W2430 W361524 REFR MW / HOOD SLIDE-IN RANGE / OVEN B4D15 PLAM UNIT ENTRY DOOR FILLER AS REQ'D FILLER AS REQ'D 15 " 69 " 7' - 0 " W3012 W2430 W3618 W2430 W361524 REFR PLAM COUNTERTOP DW SB36 SS SINK W/ SINGLE LEVER FAUCET SL S 3 6 SLIDE-IN RANGE / OVEN MW / HOOD FILLER AS REQ'D 7' - 0 " 30 " 18 " 36 " ENLARGED FLOOR PLAN NOTES 1. ALL INTERIOR UNIT PLAN DIMENSIONS ARE FROM FACE OF BARE STUD TO FACE OF BARE STUD, U.N.O. (UNLESS NOTED OTHERWISE). 2. ALL INTERIOR WALLS TO GO TO STRUCTURE ABOVE, U.N.O. 3. ALL DIMENSIONS PROVIDED FOR WALLS BATHROOM TUBS AND SHOWERS ARE TO BE VERIFIED WITH FIXTURE MANUFACTURER. 4. VERIFY TYPE A UNITS WITH SITE PLAN 5. PROVIDE GRAB BARS PER ACCESSIBILITY DETAILS @ UNIT 2101 Sheet No. Sheet Title D C B A 12345 D C B A 12345 REAL ESTATE DEVELOPMENT & MANAGEMENT 200 N. MAIN STREET OREGON, WI 53575 Plot Date: Project No. Drawn by: Consultant Seal Issue Date: 7/8/2015 1:36:34 PM A401 ENLARGED SCALE UNIT PLANS LI O N ' S R I D G E A P A R T M E N T HO M E S 12 6 5 N . F r o n t a g e R o a d W e s t To w n o f V a i l , C O 8 1 6 5 7 14LION-00-01 crd/dmk 2014.03.14 SCALE: 1/4" = 1'-0" 1 MODEL A SCALE: 1/4" = 1'-0" 4 MODEL B SCALE: 1/4" = 1'-0" 7 MODEL C SCALE: 1/4" = 1'-0" 10 MODEL D SCALE: 3/8" = 1'-0" 2 MODEL A KITCHEN 1 SCALE: 3/8" = 1'-0" 3 MODEL A KITCHEN 2 SCALE: 3/8" = 1'-0" 5 MODEL B KITCHEN 1 SCALE: 3/8" = 1'-0" 6 MODEL B KITCHEN 2 SCALE: 3/8" = 1'-0" 8 MODEL C KITCHEN 1 SCALE: 3/8" = 1'-0" 9 MODEL C KITCHEN 2 SCALE: 3/8" = 1'-0" 11 MODEL D KITCHEN 1 SCALE: 3/8" = 1'-0" 12 MODEL D KITCHEN 2 UNITS 1102, 1104, 1106, 2102, 2106, 3110, 4104, 4106, AND 4108 ARE TYPE 'B' ACCESSIBLE. DIMENSIONED CLEARANCES REFER TO THESE UNITS. UNITS 1103, 1105, 2103, 2105, 2107, 3102, 3103, 4101, 4103, 4105, 4107, AND 4111 ARE TYPE 'B' ACCESSIBLE. DIMENSIONED CLEARANCES REFER TO THESE UNITS. UNITS 3108, 4102, 4110, AND 4112 ARE TYPE 'B' ACCESSIBLE. DIMENSIONED CLEARANCES REFER TO THESE UNITS. UNITS 1101, 3101, AND 3107 ARE TYPE 'B' ACCESSIBLE. DIMENSIONED CLEARANCES REFER TO THESE UNITS. Date Issue Description 2014.04.10 2014.04.10 2014.04.10 2014.04.10 REVISION 1 REVISION 1 REVISION 1 REVISION 1 2015.07.02 2015.07.02 2015.07.02 2015.07.02 BULLETIN 7 BULLETIN 7 BULLETIN 7 BULLETIN 7 E4 X3'-0" 7'-0" X 3' - 0 " 8' - 0 " X3'-0" 7'-0" 1 9 3 3 REFR DW RA N G E AH U WH W/D DOOR ID VARIES BY BLDG & FLOOR DO O R I D V A R I E S BY B L D G & F L O O R DOOR ID VARIES BY BLDG & FLOOR KITCHEN UTILITIES LIVING / DINING AREA BEDROOM MASTER BEDROOM WIC MASTER BATH BATH COATS PATIO STORAGE A402 2 3 W1A W5 W5 W1A W4 W4 W3 W3 W3 W4 W4 W4 W4 W4A W4 W4 W4 W4 12'-2 1/2" -5'-9" -5'-8" -10'-2" 34'-8" 6' - 4 1 / 4 " - 2' - 1 0 " 1' - 6 " 10 ' - 1 0 1 / 2 " 21 ' - 1 0 1 / 4 " 9'-2" 4'-4 1/2" -11'-8" -2'-1" -10'-3" 3' - 8 1 / 2 " - 5' - 8 " 4' - 0 1 / 2 " - 10 ' - 1 0 1 / 2 " 6' - 1 0 1 / 4 " - 1' - 1 0 " 3' - 6 1 / 2 " 8' - 6 " 9' - 1 0 1 / 4 " 3'-9" 3' - 9 " - 2' - 1 " 7' - 9 1 / 4 " W4 16 " S H & R AP 0 1 AP01 AP 1 3 AP 0 2 AP 0 2 16 " S H & R AP11 8' - 0 " 5'-0" ALL PATIO RAILS 42" A.F.F CL O S E T X 5' - 0 " 7' - 0 " 9 3/4" 9 3 / 4 " PATIO VARIES BY FLOOR MW / H O O D VS 6 D 4 8 B VS6D48B W1830 W2430 W3012 W1530 MW / HOOD SLIDE-IN RANGE / OVEN B4D15 DW SS SINK W/ SINGLE LEVER FAUCET PLAM COUNTERTOP SL S 3 6 FILLER AS REQ'D 36 " 18 " 30 " UNIT ENTRY DOOR 7' - 0 " W361524 W1830 W3618 W2430 W3012 MW / HOOD SLIDE-IN RANGE / OVEN SL S 3 6 SS SINK W/ SINGLE LEVER FAUCET PLAM COUNTERTOP SB36 DW W1830 B12 REFR 7' - 0 " 36 " 18 " 30 " FILLER AS REQ'D MODEL AA W5 0 2 4 8'-4" 5 1/2" 2'-10" -11'-8" - 14 ' - 8 1 / 2 " 5 1 / 2 " 8' - 0 " 9' - 1 0 1 / 2 " - 5' - 2 " - 11'-7 1/2" -11'-8" - 1' - 1 1 " - 1' - 1 0 " 9' - 3 1 / 2 " 2'-1" AP03 AP11 AP 0 2 AP 0 1 W4 W4 W4A W3 W3 E4 W4 W4 W4 W4 X 4' - 0 " 7' - 0 " X 5' - 0 " 7' - 0 " TYPE A FRONT LOADING WASHER FRONT LOADING DRYER DINING / LIVING AREA KITCHEN BEDROOM BATH AH U CLOSET 12" SH & R 16 " S H & R CL O S E T A402 7 5 D O O R I D V A R I E S B Y B L D G & F L O O R DO O R I D V A R I E S BY B L D G & F L O O R DOOR ID VARIES BY BLDG & FLOOR X3'-0" 7'-0" X 3' - 0 " 8' - 0 " X 3' - 0 " 7' - 0 " MO D U L A R T U B SU R R O U N D STORAGE PATIO AL L P A T I O R A I L S = 4 2 " A . F . F . REFR RANGE MW DW VS B 3 6 B H C R F HOOD WH ABOVE ø 5'-0" 30"x48" MODEL CA E1 E1 E1 3'-3 1/2" 4'-0" 3'-0" E1 E1 E1 W5 21 ' - 5 3 / 4 " 2' - 1 0 " 2 0 33 5' - 6 1 / 4 " - 15 ' - 2 1 / 2 " 10'-0" 12'-6" -1'-10" 2'-2" 6'-10 1/2" 10'-0 1/2" -5'-9 1/2" -6'-3 1/2" -10'-8" 4' - 0 1 / 2 " 3' - 1 0 " - 5' - 6 1 / 2 " 5 1 / 2 " 8' - 0 " 9' - 8 " - 3' - 9 " - 2' - 4 1 / 2 " 7' - 5 3 / 4 " 8' - 1 0 1 / 4 " - 2' - 8 " 9' - 2 1 / 2 " AP12 AP 0 1 AP 1 2 AP 0 2 AP01 AP 0 2 X 4' - 0 " 7' - 0 " X 5' - 0 " 7' - 0 " MASTER BEDROOM CL O S E T MASTER BATH BATH COATS BEDROOM LIVING / DINING AREA KITCHEN UTILITIES PATIO STORAGE DW RA N G E WH AH U FRONT LOADING WASHER REFR DOOR ID VARIES BY BLDG & FLOOR DO O R I D V A R I E S BY B L D G & F L O O R ALL PATIO RAILS 42" A.F.F DOOR ID VARIES BY BLDG & FLOOR FRONT LOADING DRYER CL O S E T X3'-0" 7'-0" X 3' - 0 " 8' - 0 " X3'-0" 7'-0" TYPE A MW 16 " S H & R 16 " S H & R 12" SH & R A402 9 8 16" SH MO D U L A R T U B SU R R O U N D 36 X 3 6 R O L L - I N HO O D VR F 4 8 VS6D48B ø 5'-0" 30"x48" 30"x48" 30"x48" 7 7 ENLARGED FLOOR PLAN NOTES 1. ALL INTERIOR UNIT PLAN DIMENSIONS ARE FROM FACE OF BARE STUD TO FACE OF BARE STUD, U.N.O. (UNLESS NOTED OTHERWISE). 2. ALL INTERIOR WALLS TO GO TO STRUCTURE ABOVE, U.N.O. 3. ALL DIMENSIONS PROVIDED FOR WALLS BATHROOM TUBS AND SHOWERS ARE TO BE VERIFIED WITH FIXTURE MANUFACTURER. 4. VERIFY TYPE A UNITS WITH SITE PLAN 5. PROVIDE GRAB BARS PER ACCESSIBILITY DETAILS @ UNIT 2101 PLAM COUNTERTOP UNIT ENTRY DOOR 34 " OPEN BELOW 34 " RANGE HOOD CONTROL 34 " 14 " 36 " 84 " W3936 W3018 W1836 B4D18 FRONT CONTROL RANGE A.D.W. W2 4 3 6 SS SINK W/ SINGLE LEVER FAUCET PLAM COUNTERTOP MW RANGE HOOD OPEN BELOW FILLER AS REQ'D END PANEL - COUNTERTOP SUPPORT UNIT ENTRY DOOR RANGE HOOD CONTROL FILLER AS REQ'D END PANEL - COUNTER SUPPORT W361524 W2436 W3624 W2436 W3018 RANGE HOOD FRONT CONTROL RANGE SS SINK W/ SINGLE LEVER FAUCET PLAM COUNTERTOP A.D.W. REFR SB36BHCRF 36 " 14 " 34 " 84 " Sheet No. Sheet Title D C B A 12345 D C B A 12345 REAL ESTATE DEVELOPMENT & MANAGEMENT 200 N. MAIN STREET OREGON, WI 53575 Plot Date: Project No. Drawn by: Consultant Seal Issue Date: 7/8/2015 1:36:39 PM A402 ENLARGED SCALE UNIT PLANS LI O N ' S R I D G E A P A R T M E N T HO M E S 12 6 5 N . F r o n t a g e R o a d W e s t To w n o f V a i l , C O 8 1 6 5 7 14LION-00-01 crd/dmk 2014.03.14 SCALE: 1/4" = 1'-0" 1 MODEL E SCALE: 3/8" = 1'-0" 2 MODEL E KITCHEN 1 SCALE: 3/8" = 1'-0" 3 MODEL E KITCHEN 2 SCALE: 1/4" = 1'-0" 4 MODEL A TYPE A SCALE: 1/4" = 1'-0" 6 MODEL C TYPE A SCALE: 3/8" = 1'-0" 5 MODEL AA KITCHEN 1 SCALE: 3/8" = 1'-0" 7 MODEL AA KITCHEN 2 SCALE: 3/8" = 1'-0" 8 MODEL CA KITCHEN 1 SCALE: 3/8" = 1'-0" 9 MODEL CA KITCHEN 2 UNITS 2101 AND 4109 UNITS 1107 AND 3105 UNITS 1108 AND 2108 ARE TYPE 'B' ACCESSIBLE. DIMENSIONED CLEARANCES FEFER TO THESE UNITS. Date Issue Description 2014.04.10 2014.04.10 2014.04.10 2014.04.10 REVISION 1 REVISION 1 REVISION 1 REVISION 1 2015.07.02 2015.07.02 2015.07.02 2015.07.02 BULLETIN 7 BULLETIN 7 BULLETIN 7 BULLETIN 7 UP UP DN DN UP UP 8" 7'-5 1/2" 8" E1 E1 W5 W1A 8' - 6 " W5 W5 3'-9 1/2" 3'-8" 12 ' - 0 " 2' - 1 0 1 / 2 " 2' - 1 0 1 / 2 " T O B O T T O M R I S E R 1 1 '-9 7 /1 6 " 5 A403 1ST FLOOR ENTRY @ GRADE RECESS SLAB FOOT GRATE - TYP. COMPOSITE WOOD /FIBER VERTICAL SLATS U N I T E N T R Y - T Y P U N I T E N T R Y - T Y P U N I T E N T R Y - T Y P U N I T E N T R Y - T Y P 8x8 POST - SEE STRUC. 5/4" TREX TRANSCEND TREEHOUSE - TYP. E Q E Q E1 W5 W1A W5 W5 1 6 '-6 " 5 '-7 " 3'-9 1/2" 3'-8" 2 '-1 0 1 /2 " 2 '-1 0 1 /2 " 8 '-6 " 5 A403 C O M P O S I T E W O O D /F I B E R V E R T I C A L S L A T S U N I T E N T R Y - T Y P U N I T E N T R Y - T Y P U N I T E N T R Y - T Y P U N I T E N T R Y - T Y P CEDAR HORIZONTAL SLATS & TOP RAIL R @ 6 2 9 /3 2 " 1 9 15 A403 E Q E Q E Q 5 '-5 " 5 '-5 1 /1 6 " E1 W5 W1A W5 E1 W5 8 '-6 " 1 6 '-5 1 /4 " 5 '-7 " 2 '-1 0 1 /2 " 2 '-1 0 1 /2 " 3'-9 1/2" 3'-8" 5 A403 C O M P O S I T E W O O D /F I B E R V E R T I C A L S L A T S W / T O P R A I L U N I T E N T R Y - T Y P U N I T E N T R Y - T Y P U N I T E N T R Y - T Y P U N I T E N T R Y - T Y P CEDAR HORIZONTAL SLATS W/ TOP RAIL 15 A403 E Q E Q E Q E Q E Q E Q 5 '-5 " 5 A403 48X22 ATTIC ACCESS PANEL @ EA 4 UNITS SEE DETAIL (10/A502) 5/8" GWB OVER 1/2" RESILIENT CHANNEL @ 12" O.C. CEILING SYSTEM W5 W5 W1A W1A W5 W1A W5 DRAFTSTOPPING ACCESS DOOR W/ CLOSER ABOVE IN ATTIC SPACE - SEE DETAIL (2/A601) 1 HOUR RATED ACCESS PANEL ABOVE IN ATTIC SPACE - SEE DETAIL (1/A601) F I N I S H E D C E I L I N G 9 '-0 " T .O . J S T - T .O . J S T 1 0 '-9 7 /8 " U N F I N F L O O R - T .O .J S T 1 0 '-9 7 /8 " R @ 6 27/32" 19 R @ 6 29/32" 19 UNIT ENTRY DOOR UNIT ENTRY DOOR UNIT ENTRY DOOR UNIT ENTRY DOOR UNIT ENTRY DOOR UNIT ENTRY DOOR F3 F3 16'-5" W5 W5 W5 15 A403 TOP OF DECKING 21'9" TOP OF DECKING 10' 11 1/8" A403 12 A403 13 A301 4 A403 14 NON-SKID STAINED CONCRETE - STANDARD COLOR BY ARCHITECT CLOSED STRINGER @ CUT END OF TREADS - TYP. A403 11 5/4" FIBER COMPOSITE DECKING - TYP. COLOR FROM STANDARD COLORS 7 5'-5" 5'-3 1/4" 6'-8 3/4" EQ EQ EQ EQ EQ EQ HANDRAIL TO EXTEND 12" PAST TREAD 11" 7'-5 1/2" 8" W1A W2 E1 E5 E1 3112A 2 W5 1ST FLOOR ENTRY @ GRADE C O M P O S I T E W O O D /F I B E R V E R T I C A L S L A T S U N I T E N T R Y - T Y P 1 2 '-0 " T O B O T T O M R I S E R 1 1 '-1 0 " 3'-9 1/2" 3'-8" RECESS SLAB FOOT GRATE - TYP. 4 '-9 " 5'-5 1/2" U N I T E N T R Y - T Y P 1 '-6 " R @ 6 2 7 /3 2 " 1 9 E4 10 A403 MECHANICAL CHASE 5/4" TREX TRANSCEND TREEHOUSE - TYP. 8x8 POST - SEE STRUC. E Q E Q E5 E1 E1 10 STAIRS 3212 C O M P O S I T E W O O D /F I B E R V E R T I C A L S L A T S U N I T E N T R Y - T Y P U N I T E N T R Y - T Y P CEDAR HORIZONTAL SLATS & TOP RAIL - 42" HT TYP 1 1 '-1 0 " 1 6 '-7 " 7 '-7 " 3'-9 1/2" 3'-8" E4 W2 W5 R @ 6 2 7 /3 2 " 1 9 10 A403 7 '-6 " E Q E Q E Q E Q E Q E Q E1 E5 E1 10 C O M P O S I T E W O O D /F I B E R V E R T I C A L S L A T S W / T O P R A I L - 4 2 H T T Y P . U N I T E N T R Y - T Y P U N I T E N T R Y - T Y P CEDAR HORIZONTAL SLATS W/ TOP RAIL - 42" HT TYP. E4 W2 W5 6 '-3 1 5 /1 6 " 3'-9 1/2" 3'-8" T O P R I S E R 7 '-7 " 10 A403 E Q E Q E Q E Q E Q E Q 7 '-6 " 5 '-5 " W2 W5 W1A W1A E4 W2 10 A403 1'-10" 4 '-0 " A502 10 48X22 ATTIC ACCESS PANEL @ EA 4 UNITS 5/8" GWB OVER 1/2" RESILIENT CHANNEL @ 12" O.C. CEILING SYSTEM E5 T .O . J S T T O T R U S S B E A R I N G 9 '-1 1 /8 " T .O J S T - T .O J S T 1 0 '-9 7 /8 " U N F I N F L O O R T O T .O J S T 1 0 '-9 7 /8 " F3 F3 R @ 6 27/32" 19 R @ 6 27/32" 19 CHASE CAVITY 16'-6" E4 TOP OF DECKING 21'-9" TOP OF DECKING 10' 11 1/8" 1 0 '-1 1 1 /8 " A403 11 A403 12 A403 13 A403 14 A301 4 Sim CLOSED STRINGER @ CUT END OF TREADS - TYP 5/4" FIBER COMPOSITE DECKING - TYP. COLOR FROM STANDARD COLORS NON-SKID STAINED CONCRETE - STANDARD COLOR BY ARCHITECT 7 7'-6" 5'-3 1/4" 6'-5 3/4" EQ EQ EQ EQ EQ EQ HANDRAIL TO EXTEND 12" PAST TREAD 2x4 STAINED CEDAR TOP CAP 1x6 STAINED STK CEDAR SLAT GUARDRAIL 4x12 FLOOR FRAMING 4X4 STAINED DOUGLAS FIR POSTS TO UNDERSIDE OF TOP CAP 2x TREX DECKING RIP TOP SLAT TO ALIGN W/ T.O. CAP AS REQ'D PROVIDE BLOCKING AS REQ'D 1x6 SLAT SCREEN W/ 1/4" REVEAL ATTACHED TO UNDERSIDE OF FLOOR FRAMING RECESSED TIMBERLOK SCREWS 11 3/16" 1" 2x DECKING TREADS WOOD STRINGER - TYP SEE STRUCTURAL 11 3/16" 1" SEE STRUCTURAL FOR FRAMING INFO 5/4" RISER TYP. 2x DECKING TREADS 5/4" RISER TYP. SEE STRUCTURAL FOR FRAMING INFO 11" 1" 5/4" FIBER COMPOSITE DECKING 2x4 STAINED CEDAR TOP CAP BETWEEN POSTS 1x6 STAINED STK CEDAR SLAT GUARDRAIL FLOOR SYSTEM @ STAIRS 4X4 POST PROVIDE TRIM DECKING AT EDGE OFF END CUT DECK BOARDS - TYP. 2" DIA. WOOD RAILING W/ 1 1/2" GAP CLEAR TO WALL 7 Sheet No. Sheet Title D C B A 12345 D C B A 12345 REAL ESTATE DEVELOPMENT & MANAGEMENT 200 N. MAIN STREET OREGON, WI 53575 Plot Date: Project No. Drawn by: Consultant Seal Issue Date: 7/8/2015 1:36:40 PM A403 ENLARGED SCALE STAIR PLANS LI O N ' S R I D G E A P A R T M E N T HO M E S 12 6 5 N . F r o n t a g e R o a d W e s t To w n o f V a i l , C O 8 1 6 5 7 14LION-00-01 crd 2014.03.14 SCALE: 1/4" = 1'-0" 1 1ST FLOOR SCALE: 1/4" = 1'-0" 2 2ND FLOOR SCALE: 1/4" = 1'-0" 3 3RD FLOOR SCALE: 1/4" = 1'-0" 4 RCP SCALE: 1/4" = 1'-0" 5 SECTION THROUGH STAIRS - TYPICAL SCALE: 1/4" = 1'-0" 6 1ST FLOOR SCALE: 1/4" = 1'-0" 7 2ND FLOOR SCALE: 1/4" = 1'-0" 8 3RD FLOOR SCALE: 1/4" = 1'-0" 9 RCP STAIRS @ FIRE WALL STAIRS @ FIRE WALL STAIRS @ FIRE WALL STAIRS @ FIRE WALL TYPICAL STAIRS TYPICAL STAIRS TYPICAL STAIRS TYPICAL STAIRS SCALE: 1/4" = 1'-0" 10 SECTION THROUGH STAIRS @ FIRE WALL SCALE: 1/2" = 1'-0" 11 RAILING @ CORRIDORS SCALE: 1" = 1'-0" 12 STAIRS @ CONCRETE FLOOR SCALE: 1" = 1'-0" 13 TERMINATION @ LANDING SCALE: 1" = 1'-0" 14 1ST RISER @ LANDING SCALE: 1/2" = 1'-0" 15 DTL-GUARDRAIL @ STAIRS BLDG 3 BLDG 3 BLDG 3 BLDG 3 Date Issue Description 2014.04.10 2014.04.10 2014.04.10 2014.04.10 REVISION 1 REVISION 1 REVISION 1 REVISION 1 2014.12.15 2014.12.15 2014.12.15 2014.12.15 BULLETIN 4 BULLETIN 4 BULLETIN 4 BULLETIN 4 2015.07.02 2015.07.02 2015.07.02 2015.07.02 BULLETIN 7 BULLETIN 7 BULLETIN 7 BULLETIN 7 NOTE: INSTALLER TO REFER TO INTERIOR DESIGN DRAWINGS FROM BERGLUND ARCHITECTS. NOTES:31 CSST GAS RISERS TO UNITS ABOVE.37 CSST GAS RISERS TO UNITS ABOVE.31 CSST GAS TO UNIT. PROVIDE MANUAL SHUT-OFF VALVE AT UNIT. RE: M401 FOR CONTINUATION.37 CSST GAS TO UNIT. PROVIDE MANUAL SHUT-OFF VALVE AT UNIT. RE: M401 FOR CONTINUATION.1-1/4" DCW TO UNIT. PROVIDE MANUAL SHUTOFF VALVE AT EACH UNIT.RE: ENLARGED MODEL PLANS FOR EXTENTS &COORDINATION OF PIPING & VENTING IN MAIN CHASE WALL, TYP.DCW ROUTED AROUND ST AIRWELL PERIMETERS &PIPED WITHIN UNIT SIDEWALL ASSEMBLY.1" DCW TO UNIT. PROVIDE MANUAL SHUTOFF VALVE AT EACH UNIT.1FLAG NOTES: SC A L E : 1 BL D G . 3 - 1 S T F L O O R M E C H A N I C A L P L A N 1/ 8 " = 1 ' - 0 " SC A L E : 2 BL D G . 3 - 2 N D F L O O R M E C H A N I C A L P L A N 1/ 8 " = 1 ' - 0 " 2 3 4 5 RE: M401 FOR TYPICAL BEDROOM LAYOUT.DOMESTIC WATER AND FIRE SPRINKLER ENTRY.STACKED GAS METERS,18 TOTAL.RE: M401 FOR TYPICAL 2 BEDROOM LAYOUT. ST A C K E D G A S ME T E R S , 1 2 TO T A L . C. O . T . G . 6" W , I . E . = 8 0 9 0 . 3 ' . W FI R E C A U L K D C W PE N E T R A T I O N S O F FI R E W A L L S A N D B A R R I E R S . 1 W 1 2 5 4 1 3 5 1 31. CEILING COORDINATION OF ALL MEP SYSTEMS (LIGHTING, DUCTWORK, DIFFUSERS, ELECTRICAL,FIRE PROTECTION, ETC.) MUST BE COMPLETED BY THE CONTRACTOR PRIOR TO THE START OF ANY INSTALLATIONS.2. AVOID ROUTIN G DUCTWORK OVER ELECTRICAL ROOMS OR ELECTRICAL PANELS; MAINTAIN N.E.C.CLEARANCES. COOR DINATE ROUTINGS WITH DIV. 16 CONTRACTOR.3. RE: D/M501 FOR CLEANOUT DIAGRAMS.4. RE: B & C/M501 FOR DOMESTIC WATER ENTRANCE DIAGRAMS.5. RE: A/M501 FOR FIRE ENTRY PIPING DIAGRAM.6. NOT ALL REQUIRED CLEANOUTS ARE NECESSARILY SHOWN ON THESE PLANS. PROVIDE CLEANOUTS ON WASTE, VENT AND STORM PIPING AS REQUIRED BY CODE AND FOR REASON ABLE MAINTENANCE BASED ON ACTUAL FIELD INSTALLATION. COORDINATE LOCATIONS WITH ARCHITECT/ENGINEER.7. PIPING ON EXTERIOR WALLS OR PRE-CAST CONCRETE WALLS TO BE ROUTED IN FRAMED WALL ON INTERIOR SIDE OF INSULATION.8. PEX PIPING SHALL NOT BE ALLOWED TO PENETRATE FIRE BARRIERS WHERE FIRE CAULKING IS REQUIRED.TRANSITION TO EQUIVALENT OR LARGER SIZE STEEL OR COPPER AT PENETRATION AND PROVIDE FIRE RATED ACCESS PANELS TO FITTINGS.9. ALL VALVES SHALL BE INSTALLED ABOVE DROP-IN CEILINGS IN ACCESSIBLE LOCATIONS, OR WITH ACCESS PANELS IN HARD-LID CEILINGS.6 P 3 P 2 5 3 5 3 P 1 P 2 8 3 ROUTE DCW IN WALL ABOVE DOOR HEADERS, TYP. SHOWN OFFSET FOR CLARITY. 5 3 W P 2P1 P 4 P 2 P 2 P 3 W HP11 4"DCW TO BUILDING FROM CIVIL4"FIRE SPRINKLER SERVICE TO BUILDING FROM CIVIL.FROUTE 2-1/2" DCW IN MAIN CHASE WALL TO RISERS.FIRE SPRINKLER LINE TO FIRE PROTECTION SERVICE BY DESIGN BUILD CONTRACTOR.P1P3P2 P 2 P 2 P 1 P 4 P 2 P 2 P 3 P 1 1 3 7 3 56 1 3 5 3 5 1 3 5 3 5 1 3 7 3 7 1 3 7 3 5 8 5 4 83 8 3 RE : M 4 0 2 F O R T Y P I C A L 2- B E D R O O M AC C E S S I B L E U N I T LA Y O U T . 7 7 7 7 8 CSST GAS LINES ROUTED IN CEILING JOIST SPACE TO FIRST FLOOR UNITS AND RISER LOCATIONS. (18) TOTAL SHOWN AS STACKED (2) HIGH. FIRE CAULK ALL PENETRATIONS OF HARD LID CEILINGS AND W1A WALL ASSEMBLIES TYP., RE: ARCH FFI.(2) G(2 ) G (2) G (12) CSST GAS LINES. PROVIDE TRANSITION FROM CSST TO EQUIVALENT SIZE STEEL PIPE FOR PENETRATOINS OF W2 WALL ASSEMBLIES,RE: ARCH FFI. GROUP STEEL PIPING AND PENETRATE THE ARCHITECTURAL SHAFT ON THE SOUTH END OF STAIRWELL 3112. FIRE CAULK ALL PENETRATIONS INTO AND OUT OF THE SHAFT AND PROVIDE FIRE RATED ACCESS PANELS AT CSST TRANSITIONS. (2 ) G (2 ) G (2 ) G (2 ) G (2 ) G (2 ) G 5 (2 ) G (2 ) G (2 ) G (2 ) G (2 ) G (2 ) G CS S T G A S L I N E S R O U T E D I N C E I L I N G J O I S T SP A C E T O F I R S T F L O O R U N I T S A N D R I S E R LO C A T I O N S . ( 1 2 ) T O T A L S H O W N A S S T A C K E D (2 ) H I G H . F I R E C A U L K A L L P E N E T R A T I O N S O F HA R D L I D C E I L I N G S A N D W 1 A W A L L AS S E M B L I E S T Y P . , R E : A R C H F F I . 1"CW TO IRRIGATION SERVICES FROM DEDICATED METER IN FIRE SPRINKLER ROOM. BACKFLOW PREVENTOR AND METER PROVIDED BY OTHERS, CDBBC.1"CW TO IRRIGATION SERVICES FROM DEDICATED METER IN FIRE SPRINKLER ROOM. BACKFLOW PREVENTOR AND METER PROVIDED BY OTHERS, CDBBC.7 Sheet  No.Sheet  TitleDCBA1 2 3 4 5 D C B A 1 2 3 4 5 REAL  ESTATE DEVELOPMENT  &MANAGEMENT 200  N. MAIN  STREET OREGON, WI  53575 Plot  Date:BGCE  Project  No.Drawn  by:ConsultantSeal 3/14/2014 4:00:00 PMLION'S RIDGE APARTMENT HOMES 1280 N. Frontage Road West Town of Vail, CO 81657 9443.00  Date Issue  DescriptionCOPYRIGHT 2014BANZEGEAUDIN (970) 949-6108 (303) 278-3820 (970) 221-5691 (505) 323-9070 (307) 739-3944Vail:Denver:Fort Collins:Albuquerque:Jackson:www.bgce.com  01/29/14 Design  Development  03/14/14 Bid  and  Building  Permit  04/10/14 Revision  1  09/26/14 Bulletin  2  12/15/14 Bulletin  4  01/20/15 Bulletin  5  03/27/15 Bulletin  6  07/02/15 Bulletin  7 M131BLDG 3  F1  & F2 MECHANICAL  PLANSSMW/ZRW SC A L E : 1 BL D G . 3 - 3 R D F L O O R M E C H A N I C A L P L A N 1/ 8 " = 1 ' - 0 " SC A L E : 2 BL D G . 3 - R O O F M E C H A N I C A L P L A N 1/ 8 " = 1 ' - 0 " FLAG NOTES:NOT USED.31 CSST GAS TO UNIT. PROVIDE MANUAL SHUTOFF VALVE AT UNIT. RE: M401 FOR CONTINUATION.37 CSST GAS TO UNIT. PROVIDE MANUAL SHUTOFF VALVE AT UNIT. RE: M401 FOR CONTINUATION.1-1/4" DCW TO UNIT. PROVIDE MANUAL SHUTOFF VALVE AT EACH UNIT.RE: ENLARGED MODEL PLANS FOR EXTENT AND COORDINATION OF PIPING & VENTING IN MAIN CHASE WALL, TYP.1" DCW TO UNIT. PROVIDE MANUAL SHUTOFF VALVE AT EACH UNIT.1 2 3 4 51. CEILING COORDINATION OF ALL MEP SYSTEMS (LIGHTING, DUCTWORK, DIFFUSERS, ELECTRICAL,FIRE PROTECTION, ETC.) MUST BE COMPLETED BY THE CONTRACTOR PRIOR TO THE START OF ANY INSTALLATIONS.2. AVOID ROUTIN G DUCTWORK OVER ELECTRICAL ROOMS OR ELECTRICAL PANELS; MAINTAIN N.E.C.CLEARANCES. COOR DINATE ROUTINGS WITH DIV. 16 CONTRACTOR.3. ROOF PENETRATIONS MIN. 4' FROM FIREWALLS.4. RE: E/M501 FOR VTR DIAGRAM.5. NOT ALL REQUIRED CLEANOUTS ARE NECESSARILY SHOWN ON THESE PLANS. PROVIDE CLEANOUTS ON WASTE, VENT AND STORM PIPING AS REQUIRED BY CODE AND FOR REASONABL E MAINTENANCE BASED ON ACTUAL FIELD INSTALLATION. COORDINATE LOCATIONS WITH ARCHITECT/ENGINEER.6. PIPING ON EXTERIOR WALLS OR PRE-CAST CONCRETE WALLS TO BE ROUTED IN FRAMED WALL ON INTERIOR SIDE OF INSULATION.7. TERMINATE PLUMBING VENTS NOT LESS THAN 12"ABOVE ROOF.8. PEX PIPING SHALL NOT BE ALLOWED TO PENETRATE FIRE BARRIERS WHERE FIRE CAULKING IS REQUIRED TRANSITION TO EQUIVALENT OR LARGER SIZE STEEL OR COPPER AT PENETRATIONS AND PROVIDE FIRE RATED ACCESS PANELS TO FITTINGS.9. ALL VALVES SHALL BE INSTALLED ABOVE DROP-IN CEILINGS IN ACCESSIBLE LOCATIONS, OR WITH ACCESS PANELS IN HARD-LID CEILINGS.10. ALL 3RD FLOOR DUCTWORK SHALL BE INSULATED WITH MIN. R8 INSULATION.11. OFFSET VENTS AND EXHAUST DUCTS IN ATTIC WITH 45° FITTINGS IF POSSIBLE.12. LOCATE ALL VENT AND COMBUSTION AIR TERMINATIONS ON NORT H SIDE OF ROOF TO PREVENT VISIBILITY FROM FRONTAGE ROAD.NOTES: 24 26 4 P 3 P 2 P 4 P 2 P 1P2 3 6 6 4 24 P 3P26 24 P 1P24 5 2 2 2 2 SI X ( 6 ) C O N C E N T R I C 3 " W H - 1 TE R M I N A T I O N S . M I N I M U M 4 ' F R O M A L L AD J A C E N T V E N T S R E : A R C H & P A I N T I N G SP E C F O R E X T E R I O R F I N I S H E S . SI X ( 6 ) C O N C E N T R I C 3 " F - 1 TE R M I N A T I O N S . M A X I M U M D I S T A N C E FR O M A D J A C E N T F - 1 T E R M I N A T I O N S OF 4 " . R E : A R C H & P A I N T I N G S P E C FO R E X T E R I O R F I N I S H E S . TW O ( 2 ) 4 " V T R . 61 7 7 Sheet  No.Sheet  TitleDCBA1 2 3 4 5 D C B A 1 2 3 4 5 REAL  ESTATE DEVELOPMENT  &MANAGEMENT 200  N. MAIN  STREET OREGON, WI  53575 Plot  Date:BGCE  Project  No.Drawn  by:ConsultantSeal 3/14/2014 4:00:00 PMLION'S RIDGE APARTMENT HOMES 1280 N. Frontage Road West Town of Vail, CO 81657 9443.00  Date Issue  DescriptionCOPYRIGHT 2014BANZEGEAUDIN (970) 949-6108 (303) 278-3820 (970) 221-5691 (505) 323-9070 (307) 739-3944Vail:Denver:Fort Collins:Albuquerque:Jackson:www.bgce.com  01/29/14 Design  Development  03/14/14 Bid  and  Building  Permit  04/10/14 Revision  1  09/26/14 Bulletin  2  12/15/14 Bulletin  4  01/20/15 Bulletin  5  03/27/15 Bulletin  6  07/02/15 Bulletin  7 M132BLDG 3  F1  & ROOF MECHANICAL  PLANSSMW/ZRW SC A L E : 1 BL D G 4 - 3 R D F L O O R M E C H A N I C A L P L A N 1/ 8 " = 1 ' - 0 " SC A L E : 2 BL D G 4 - R O O F M E C H A N I C A L P L A N 1/ 8 " = 1 ' - 0 " FLAG NOTES:31 CSST GAS TO UNIT. PROVIDE MANUAL SHUTOFF VALVE AT UNIT. RE: M401 FOR CONTINUATION.37 CSST GAS TO UNIT. PROVIDE MANUAL SHUTOFF VALVE AT UNIT. RE: M401 FOR CONTINUATION.1-1/4" DCW TO UNIT. PROVIDE MANUAL SHUTOFF VALVE AT EACH UNIT.RE: ENLARGED MODEL PLANS FOR EXTENT AND COORDINATION OF PIPING & VENTING IN MAIN CHASE WALL, TYP.1" DCW TO UNIT. PROVIDE MANUAL SHUTOFF VALVE AT EACH UNIT.1 2 3 41. CEILING COORDINATION OF ALL MEP SYSTEMS (LIGHTING, DUCTWORK, DIFFUSERS,ELECTRICAL, FIRE PROTECTION, ETC.) MUST BE COMPLETED BY THE CONTRACTOR PRIOR TO THE START OF ANY INSTALLATIONS.2. AVOID ROUTING DUCTWORK OVER ELECTRICAL ROOMS OR ELECTRICAL PANELS; MAINTAIN N.E.C. CLEARANCES. COORDINATE ROUTINGS WITH DIV. 16 CONTRACTOR.3. ROOF PENETRATIONS MIN. 4' FROM FIREWALLS.4. RE: E/M501 FOR VTR DIAGRAM.5. NOT ALL REQUIRED CLEANOUTS ARE NECESSARILY SHOWN ON THESE PLANS.PROVIDE CLEANOUTS ON WASTE, VENT AND STORM PIPING AS REQUIRED BY CODE AND FOR REASONABLE MAINTENANCE BASED ON ACTUAL FIELD INSTALLATION. COORDINATE LOCATIONS WITH ARCHITECT/ENGINEER.6. PIPING ON EXTERIOR WALLS OR PRE-CAST CONCRETE WALLS TO BE ROUTED IN FRAMED WALL ON INTERIOR SIDE OF INSULATION.7. TERMINATE PLUMBING VENTS NOT LESS THAN 12" ABOVE ROOF.8. PEX PIPING SHALL NOT BE ALLOWED TO PENETRATE FIRE BARRIERS WHERE FIRE CAULKING IS REQUIR ED. TRANSITION TO EQUIVALENT OR LARGER SIZE STEEL OR COPPER AT PENETRATIONS AND PROVIDE FIRE RATED ACCESS PANELS TO FITTINGS.9. ALL VALVES SHALL BE INSTALLED ABOVE DROP-IN CEILINGS IN ACCESSIBLE LOCATIONS,OR WITH ACCESS PANELS IN HARD-LID CEILINGS.10. ALL 3RD FLOOR DUCTWORK SHALL BE INSULATED WITH MIN R8 INSULATION.11. OFFSET VENTS AND EXHAUST DUCTS IN ATTIC WITH 45° FITTINGS IF POSSIBLE.12. LOCATE ALL VENT AND COMBUSTION AIR TERMINATIONS ON NORT H SIDE OF ROOF TO PREVENT VISIBILITY FROM FRONTAGE ROAD.NOTES: 1 5 P 3P2 3 2 3 P 1P2 3 1 3 P 1P2 3 1 5 P 3P23 2 3 P 1P2 3 1 5 P 4P2 5 4 SI X ( 6 ) C O N C E N T R I C 3 " W H - 1 TE R M I N A T I O N S . M I N I M U M 4 ' F R O M A L L AD J A C E N T V E N T S R E : A R C H & P A I N T I N G SP E C F O R E X T E R I O R F I N I S H E S . SI X ( 6 ) C O N C E N T R I C 3 " F - 1 TE R M I N A T I O N S . M A X I M U M D I S T A N C E FR O M A D J A C E N T F - 1 T E R M I N A T I O N S OF 4 " . R E : A R C H & P A I N T I N G S P E C FO R E X T E R I O R F I N I S H E S . TW O ( 2 ) 4 " V T R . 51 7 7 Sheet  No.Sheet  TitleDCBA1 2 3 4 5 D C B A 1 2 3 4 5 REAL  ESTATE DEVELOPMENT  &MANAGEMENT 200  N. MAIN  STREET OREGON, WI  53575 Plot  Date:BGCE  Project  No.Drawn  by:ConsultantSeal 3/14/2014 4:00:00 PMLION'S RIDGE APARTMENT HOMES 1280 N. Frontage Road West Town of Vail, CO 81657 9443.00  Date Issue  DescriptionCOPYRIGHT 2014BANZEGEAUDIN (970) 949-6108 (303) 278-3820 (970) 221-5691 (505) 323-9070 (307) 739-3944Vail:Denver:Fort Collins:Albuquerque:Jackson:www.bgce.com  01/29/14 Design  Development  03/14/14 Bid  and  Building  Permit  04/10/14 Revision  1  09/26/14 Bulletin  2  12/15/14 Bulletin  4  01/20/15 Bulletin  5  03/27/15 Bulletin  6  07/02/15 Bulletin  7 M142BLDG 4  F3  & ROOF MECHANICAL  PLANSSMW/ZRW 16" SH & R 12" SH  & R 16" SH & R 12 "  SH  & R 1. PROVIDE TAMPER RESISTANT RECEPTACLES IN ACCORDANCE WITH NEC 406.12.2. PROVIDE ARC-FAULT PROTECTED CIRCUIT BREAKERS FOR ALL 120 VOLT CIRCUITS IN ACCORDANCE WITH NEC 210.12.3. NMM TYPE CABLE IS NOT PERMITTED MC TYPE CABLE SHALL BE USED FOR LIGHTING AND RECEPTACLE BRANCH CIRCUITS.4. MULTISTATION SMOKE DETECTORS SHALL HAVE INTEGRAL STROBES, IN ACCESSIBLE UNITS.NOTES:NOT USED.PROVIDE ADDRESSABLE TYPE SMOKE DETECTOR CONNECTED TO FIRE ALARM SYSTEM WITH SOUNDER BASE.EF-1 IS COMBINATION EX HAUST FAN/LIGHT PROVIDE ONE (1) SWITCH TO CONT ROL FAN AND ONE (1) TO CONTROL LIGHT.PROVIDE CARBON MONOXIDE DETECTOR. CONNECT SENSOR TO CENTRAL FIRE ALARM PANEL.PROVIDE BACKING FOR CEILING FAN/LIGHT FOR TYPE 'S1' FIXTURES IN LIVING ROOMS AND BEDROOMS. PROVIDE ADD ALTERNATE PRICE FOR CEILING FAN/LIGHT SEE PRICING NOTE SHEET E000.1FLAG NOTES:2 3 S C RE F DW C C SS WP EF 1 S S S EF 1SSSS DI S P S SD SD SD H SD S WA S H E R / DR Y E R T1 S1 S2 V1 V1C WW 1 S T1 F 1 WH 1 SSS1S2 S2 S1 2 2 2 TV TV TV C OV E N / R A N G E MW / H O O D 3 3 SC A L E : 2 1- B E D R O O M A C C E S S I B L E E L E C T R I C A L P L A N 1/ 4 " = 1 ' - 0 " SC A L E : 1 2- B E D R O O M A C C E S S I B L E U N I T E L E C T R I C A L P L A N 1/ 4 " = 1 ' - 0 " SC A L E : 3 MO D E L E E L E C T R I C A L P L A N 1/ 4 " = 1 ' - 0 " 4 5 S S S S SS S H S S S S V1 PA N E L ' C ' C 2 F 1 WH 1 E- 1 5 E- 1 5 E- 7 E- 7 E- 9 E- 9 E- 1 2 E- 1 0 E - 8 E - 2 , 4 E - 6 MWOVEN/RANGE CL O T H E S DR Y E R CL O T H E S WA S H E R REF DW C C C S1 TV TV S2 S1 S2 T1 T1 EF 1 SD CO 4 2 SD 2 S1 SD 2 TV EF 1 V1 SS S C SD2 5 5 5 WW 1 S C- 2 1 C- 2 1 C- 2 1 C- 2 1 C- 1 7 C-17C-17C-17C-18C-14,16C-7C-9 SC-12 C-9 C-10 C-8 C- 2 , 4 C- 6 C- 1 9 C- 1 9 C- 2 1 C- 1 3 C- 1 3 C- 1 3 C- 1 3 C- 1 3 C- 1 3 C- 1 1 C- 1 5 C- 1 5 3 3 C- 2 0 C- 2 3 WH 2 F 1 PA N E L ' A ' EF 1 TV TV V1 T1 T1 S1 5 S S2 WW 1 A- 1 5 A- 1 5 S S S S H CO 4 SD 2 SD 2 S1 5 3 C A- 1 7 A- 2 , 4 A- 6 A- 1 9 A- 1 4 , 1 6 OV E N / RA N G E MW A- 1 8 C CC S DI S P RE F A- 1 7 A- 1 7 A- 1 7 A- 1 7 DW A- 1 0 A- 9 A- 1 2 A- 9 A- 7 C A- 7 A- 8 J A- 1 1 A- 1 3 A- 1 3 S2 S A- 2 0 A- 1 3 A- 1 3 A- 1 3 J C-17E-21E-21E-21E-21E-21 E-21 5 CO 4 J E- 1 3 E- 1 3 E- 1 3 E- 1 3 E- 1 3 5 E- 1 7 E- 1 7 E- 1 7 E- 1 7 E- 1 7 C E-11 E-23 E- 1 9 E- 1 9 E- 1 9 E- 1 7 5 PA N E L ' E ' E- 2 0 1 1 1 1 1 1 1 1 H 1 H 1 H H 1 1 H S 1 7 Sheet  No.Sheet  TitleDCBA1 2 3 4 5 D C B A 1 2 3 4 5 REAL  ESTATE DEVELOPMENT  &MANAGEMENT 200  N. MAIN  STREET OREGON, WI  53575 Plot  Date:BGCE  Project  No.Drawn  by:ConsultantSeal 3/14/2014 4:00:00 PMLION'S RIDGE APARTMENT HOMES 1280 N. Frontage Road West Town of Vail, CO 81657 9443.00  Date Issue  DescriptionCOPYRIGHT 2014BANZEGEAUDIN (970) 949-6108 (303) 278-3820 (970) 221-5691 (505) 323-9070 (307) 739-3944Vail:Denver:Fort Collins:Albuquerque:Jackson:www.bgce.com  01/29/14 Design  Development  03/14/14 Bid  and  Building  Permit  04/10/14 Revision  1  09/26/14 Bulletin  2  12/15/14 Bulletin  4  01/20/15 Bulletin  5  03/27/15 Bulletin  6  07/02/15 Bulletin  7 E402ELECTRICALDIAGRAMXXXXXXMBS