Loading...
HomeMy WebLinkAboutB11-0496 REV10 Drawings Perimeter Foundation Walls P3 to P1 approvedTRANSMITTAL FORM Project Street Address: __________ ______________________________ ___________ (Number) (Street) (Suite #) Building/Complex Name: ________________________________ Building Permits: Revised ADDITIONAL Valuations (Labor & Materials) (DO NOT include original valuation) Building: $_____________________ Plumbing: $_____________________ Electrical: $_____________________ Mechanical: $_____________________ Total: $_____________________ Description of Transmittal/ List of Changes, Items Attached: __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ (use additional sheet if necessary) Application/Permit #(s) information applies t o : A t t e n t i o n : ( ) Revisions ( ) Response to Correction Letter ____________________________________ __________________________ ___attached copy of correction letter ( ) D e f e r r e d S u b m i t t a l ____________________________________ __________________________ ( ) Other Use this form when submitting additional information for planning applications or building permits. This form is also used for requesting a revision to building permits. A two hour minimum building review fee of $110 will be charged upon reissuance of the permit. Date Received: Department of Community Development 75 South Frontage Road Vail, CO 81657 Tel: 970.479.2128 www.vailgov.com Development Review Coordinator For Office Use Only: F e e P a i d : R e c e i v e d F r o m : Cash _____ ____ Check # __ _ _______ CC: Visa / MC Last 4 CC # exp. date: A u t h o r i z a t i o n # Applicant Information (architect, contractor, owner/owner’s rep) Contact Name: ________________________________________ A d d r e s s : City _____________________ State: _______ Zip: ____________ Contact Name: _________________________________________ Contact Phone: _________________________________________ Contact E-Mail: _________________________________________ I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review ap- proved, International Building and Residential Codes and other ordinances of the Town applicable thereto. X___________________________________________________ Owner/Owner’s Representative Signature (Required) X New Submittal Submittal Cover Sheet 12/1/2014 Project:Strata - Vail OZ Architecture From:PCL Construction Services, Inc. 3003 Larimer Street 953 S Frontage Rd West Denver, CO 80205 Suite 302 Vail, CO 81657 SPECIFICATION SECTION NO. & DESCRIPTION PRIORITY STATUS CODES 1.3.C A - Immediate Response CONTRACTOR REMARKS:A/E REMARKS: CONTRACTOR'S CERTIFICATION: NAME AND SIGNATURE OF CONTRACTOR REPRESENTATIVE:NAME AND SIGNATURE OF REVIEWING AUTHORITY:Date: Ryan Kain 7 8 9 10 I certify that the above submitted items have been reviewed in detail, are correct, and in general conformance with the Contract Drawings and Specifications except as otherwise noted. 5 6 Submittal Type c. Item a. 1 2 3 4 Please see attached PCL Submittal Review Notes Page. ACTION TAKEN A - Approved B - Approved as Noted C - Revise and Resubmit D - Not Approved A - Immediate Response B - Respond within 10 days C - Respond within 15 days Submittal No: Previous Submittal No: Date:Resubmittal CONTRACT REF. DOCUMENT Spec Paragraph Number e. Drawing Sheet Number f. 03300 - Cast-In-Place Concrete PCL Construction Services Inc. Contractor Project No: 5001410 03300-22 To: Description of Item Submitted (Type, size, model number, etc.) b. Shop Drawings - Perimeter Foundation Walls P3 to P1 Action REVIEWED FURNISH AS CORRECTED REJECTED REVISE AND RESUBMIT NOT REVIEWED SUBMIT SPECIFIED ITEMCHECKING IS ONLY FOR GENERAL CONFORMANCE WITH THE DESIGNCONCEPT OF THE PEOJECT AND GENERAL COMPLIANCE WITH THEINFORMATION GIVEN IN THE CONTRACT DOCUMENTS. ANY ACTIONSHOWN IS SUBJECT TO THE REQUIREMENTS OF THE PLANS ANDSPECIFICATIONS. CONTACTOR IS RESPONSIBLEFOR DIMENSIONSWHICH SHALL BE CONFIRMED AND CORRELATED AT THE JOB SITE:FABRICATION PROCESSESAND TECHNIQUES OF CONSTRUCTION;COORDINATION OF HIS WORK WITH THAT OF ALL OTHER TRADES;AND THE SATISFACTORY PERFORMANCE OF HIS WORK. Monroe & Newell Engineers, Inc. DATE 12/02/2014 BY: PCL CONSTRUCTION SERVICES, INC. 953 S. FRONTAGE RD WEST, SUITE 302, VAIL, COLORADO 81652 TELEPHONE: (970) 470-6044 PCL Initial Submittal Review Notes Strata - Vail PCL Project No. 5001410 Subcontractor: PCL Construction Submittal #: 03300-22 Date: 12/1/2014 Revisions: N/A Revision Dates: Specification Section: 03300 – Cast-In -Place Concrete Item Description: Shop Drawings – Foundation Walls P3 to P1 Action: Variance Request (Y/N): N If so, why?: Notes: Notes to OZ Architecture and design reviewers include: • Please find attached Cast-In-Place Concrete submittal, from PCL. Submittal category is “Action”. • Submittal contains shop drawings for all perimeter walls from foundation footings to P1 SOG. • Elevations on shop drawings are not completely accurate with drawings. Elevations are mainly given for the use of rebar development and lap length with the given lift height and are based on highest elevation on the given wall section. Elevations for formsavers within keyways will be coordinated through lift drawings prior to placement. • P1 slab will be poured over the top of these wall lifts. In which, at P1 rebar dowel bars are based off of detail 1/S3.5 in lieu of detail 1/S3.6 as noted on the drawings. Please verify if this is acceptable. Reviewed By: Ryan Kain Correct # 6 @ 1 ' - 4 " f o r 1 ' - 8 " w a l l t h i c k n e s s # 6 @ 1 ' - 2 " f o r 1 ' - 1 0 " w a l l t h i c k n e s s P o u r 2 i s t o s t a r t 6 " f r o m f a c e o f N o r t h w a l l C o r r e c t . B11 B 1 0 B 9 B 8 B 9 . 3 B 9 . 1 B 8 . 8 B 8 . 1 B 7 . 7 B 7 . 8 B 7 . 9 B 7 . 6 B 7 . 5 B12 B 7 T.O.S.S. will vary as sla b s l o p e s for drainage (PCL-RK) B6B5 B 4 B 3 B 2 B 1 B 1 . 5 1 ' - 1 0 " w a l l a l o n g g r i d l i n e B 1 P o u r s t a r t s 6 " f r o m f a c e o f B 1 w a l l 12 3 4 5 1.2 2 . 5 2 . 7 3 . 4 4 . 1 4 . 4 4 . 9 3 . 5 A 1 8 Please verify if corner rebar canbe spaced at 14" O.C. per detail3 on S1.0 to match horizontal sizeand space. (PCL-RK)Yes, corner bars to be per 3/S1.0,except next to openings, then to beper Note 1 in Exterior FoundationWall Schedule on S2.0P-3A C o r r e c t 565.65.8 6 . 5 I.F. (PCL-RK) 8 " O . C . ( P C L - R K ) 9 " O K p e r E x t e r i o r F o u n d a t i o n W a l l S c h e d u l e o n S 2 . 0 P - 3 A f o r a 1 ' - 4 " t h i c k w a l l 123 4 5 6 1.22.52.7 4 . 4 4 . 6 3 . 6 5 . 4 5.5 5 . 7 3 . 5 6 . 5 1 3 1 4 1 5 1 6 1 7 P l e a s e v e r i f y t h e H o r i z o n t a l r e i n f o r c i n g i s t o b e a t 1 6 " o . c . f o r a 1 ' - 8 " t h i c k w a l l ( P C L - R K ) P l e a s e v e r i f y t h e H o r i z o n t a l r e i n f o r c i n g i s t o b e a t 1 6 " o . c . f o r a 1 ' - 8 " t h i c k w a l l ( P C L - R K ) A A 6 0 1 5 ' s s h o w n o n s c h e d u l e o n n e x t p a g e ( P C L - R K ) C o r r e c t , b a r s t o b e a t 1 ' - 4 " E . F . h o r i z o n t a l l y A 7 . 9 A 8 A 8 . 1 A 7 A 6 . 3 A 5 . 9 A 5 . 7 A 5 A 4 A 3 . 3 A 2 . 4 A1.1A1A2 A 3 A 6 A 6 . 2 A 4 . 3 @ 1 6 " o . c . ( R K - P C L ) 1 ' - 4 " ( P C L - R K ) Vertical rebar to be #8 on 9"centers. Please Confirm (PCL-RK) V e r t i c a l r e b a r t o b e # 8 o n 9 " c e n t e r s . P l e a s e c o n f i r m ( P C L - R K ) 1 ' - 4 " f r o m P 1 u p ( P C L - R K ) Beam B5 is 2'-2" deepper current beamschedule (PCL-RK) B e a m B 5 i s 2 ' - 2 " d e e p p e r c u r r e n t b e a m s c h e d u l e ( P C L - R K ) Corre c t C o r r e c t C o r r e c t C o r r e c t Yes, B5 is26"x26" Y e s , B 5 i s 2 6 " x 2 6 " C o r r e c t A 1 2 A 1 5 A 1 4 A 1 3 A 1 1 A 1 0 . 8 A 1 0 . 1 A 1 0 A9.2 A 1 5 . 2 A 1 4 . 4 A 1 3 . 9 A7.9A8A8.1A9 1 ' - 4 " ( P C L - R K ) 1 ' - 6 " ( P C L - R K ) Vertical rebar to be # 8 o n 9 " centers. Please conf i r m ( P C L - R K ) V e r t i c a l r e b a r t o b e # 8 o n 9 " c e n t e r s . P l e a s e c o n f i r m ( P C L - R K ) C o r r e c t 1617 V e r i f y h o r i z o n t a l r e b a r i s t o b e s p a c e d a t 1 4 " ( P C L - R K ) Confirm if verticals are tobe #8 at 8" o.c. (PCL-RK) # 8 v e r t s a t w a l l s 1 ' - 1 0 " t o 1 ' - 4 " S p a c i n g D e p e n d s o n W a l l t h i c k n e s s r e f e r t o S 2 . 0 P - 3 A ( P C L - R K ) S p a c i n g D e p e n d s o n W a l l t h i c k n e s s r e f e r t o S 2 . 0 P - 3 A ( P C L - R K ) S p a c i n g D e p e n d s o n W a l l t h i c k n e s s r e f e r t o S 2 . 0 P - 3 A ( P C L - R K ) Y e s h o r i z o n t a l s t o b e a t 1 4 " . #8 @ 9" fora 1'-6" wall C o r r e c t . C o r r e c t . C o r r e c t . C o r r e c t .