HomeMy WebLinkAboutDRB150405 Approved Plans r' .
.
� MITSUBISHI � � � S� �e-
/_ ELECTRIC �
COOLING & HEATING � M SERIES
....
. . , ,;
Job fJame:
System Reference: Date:
GENERALFEATURES
• Quiet Operation i� '�
• Optional base pan heater to prevent ice in drain pan �L eiIIIIII�����������IIHIIIqN. �,��
• Limited warranty:five years parts and seven years compressors �� ' � 1'CyCR
� ��BIIIIII�IIIII�IIY��nIIlBllll�i� �,,
� dllllllllllllUlnlllllllllllllill@IIIIInN
ACCESSORIES �t 911hIIIIIIII�IIIIIIluN1111111119fiIIIIIP
❑ 1/2"x 3/8"Port Adapter(MAC-A455JP-E) i� ,%��IwI��IYIIIIiNIpNl���l�lpill�''
❑ 1/2"x 5/8"Port Adapter(MAC-A456JP-E) (� �, � ��� �
❑ 1/4"x 3/8"Port Adapter(PAC-493PI) �i �
❑ 3/8"x 5/8"Port Adapter(PAGSG76RJ-E) �i �A
❑ M-NETAdapter(PAC-IF0IMNT-E) �-
❑ Base Heater(PAC-645BH-E) outdoor unit:Mxz-5C42NA
(For data on specific indoor units,see the MXZ-C Technical and Service Manual.)
S ecifications Model Name
Unit T e MXZ-SC42NA
Rated Capacity Btu/h 40,500/37,400
Cooling' Capaciry Range Btu/h 6,000-43,000
(Non-ducted/Ducted)
Rated Total Input W 4,403/4,112
Rated Capacity Btu/h 45,000/41,000
Heating at 47°F* Capacity Range Btu/h 7,200-53,600
(Non-ducted/Ducted)
Rated Total Input W 3,575/3,463
Heating at 17°F' Rated Capacity Btu/h 24,400/23,000
(Non-ducted/Ducted) Rated Total Input W 2,943/2,869
Power Supply Voltage,Phase,Hertz 208 I 230V, 1-Phase,60 Hz
Electrical Requirements Recommended Fuse/Breaker Size A 40
MCA A 31.9
Indoor-Outdoor S1-S2 V AC 208/230
Voltage Indoor-Outdoor S2-S3 V DC±24
Compressor INVERTER-driven Scroll Hermetic
Fan Motor(ECM) F.L.A. 1.9
Sound Pressure Level Heatin9 dB�A� 58
9
External Dimensions(H x W x D) In(mm) 41-9/32 x 37-13l32 x 13
(1048 x 950 x 330)
Net Weight Lbs(kg) 189(86)
External Finish Munseii No.3Y 7.8/11
Refrigerant Pipe Size O.D.— Liquid(High Pressure) In(mm) 1/4(6.35)
Eight Ports Gas(Low Pressure) A:1/2(12.7) ; B,C,D,E:3/8(9.52)
Max.Refrigerant Line Length Ft(m) 262(80)
Max.Piping Length for Each Indoor Unit Ft(m) 82(25)
Max.Refrigerant Pipe Height If IDU is Above ODU Ft m 49(15)
Difference If IDU is Below ODU � � 49(15)
Connection Method Flared/Flared
Refri erant R410A
'Rating Conditions per AHRI Sta�dard:
Cooling�Indoor:80°F(27°C)DB/67°F(19°C)WB Heating at 47°F�Indow:70°F(21°C)DB/60°F(16°C)WB Heating at 17°F�Indoor:70°F(21°C)DB
Cooling�Outdoor:95°F(35°C)DB/23 9°C(75°F)WB Heating at 47°F�Outdoor:47°F(8°C)DB/43°F(6°C)WB Heating at 17°F�Outdoor 17°F(-8°C)DB/15°F(-9°C)WB
Specifications are subject to change without notice.
OO 2015 Mitsubishi Electric US,Inc.
� ,
� MITSUBISHI �' .
/\ ELECTRIC � �^��� °'�
COOLING & HEATING 1 �� !� �t� �` J�r M SERIES
� : �
• � ���- •- • -
Job Name:
System Reference: Date:
SPECIFICATIONS
Cooling Capacity*. . . .. . . . . .. . . . . . .. . .. ..... . .17,200 Btu/h
Heating Capacity�. . . .. . . . . .. . . . .. . .. .. ..... ..21,600 Btu/h
__,a„_ . �
_.. __ _� _` � ` '� 'Rating Conditions perAHRI Standard
1—.� „ �_ .. ._ �� � �',��� Cooling�Indoor:80°F(27°C)DB/67°F(19°C)WB
Indoor Unit:MSZ-GEI8NA-9 Cooling�Outdoor:95°F(35°C)DB/75°F(24°C)WB
Heating at 47°F�Indoor:70°F(21°C)DB/60°F(16°C)WB
Heating at 47°F�Outdoor:47°F(8°C)DB/43°F(6°C)WB
(For data on specific indoor units[all ducted,all non-ducted,
�„; and both ducted and non-ducted]combinations,see the MXZ
wireiess Remote Technical and Service Manual.)
Controller
Electrical Requirements
Power Supply... . . . .. . .. . .... .. . .208/230V, 1-Phase,60 Hz
MCA. . . .. . . .... . . . .. .. . .... . .. . ... . . .. .. . .. ... . . . . 1 A
GENERAL FEATURES Voltage
• Wall-mounted indoor unit Indoor-Outdoor S1-S2 . . . ..... . .. . ... . .. . .. .AC 208/230V
• Nano Platinum and and Anti-allergy Enryme filters are included Indoor-Outdoor S2-S3 . .. . .. .. . .. . .. . . .. .. . .. . . . .DC t24V
• Quiet operation Indoor-Remote Controller. . . .. . .. . . ... . .. . . . ..MHK1 DC 3V
• Auto fan speed control:Quiet,Low,Medium,High,and Super High PAR-31 MAA DC 12V
• Hand-held Wireless Remote Controller PAC-YT53CRAU DC 12V
• Indoor unit powered from outdoor unit using A-Control
• Auto restart following a power outage Blower Motor(ECM). .... . . . . .. .. . .... . .. ..... . . 0.76 F.L.A.
• Limited warranty:five years parts and seven years compressor
Airflow(Quiet-Lo-Med-Hi-Super Hi)
Cooling.....................230-275-339-420-533 Dry CFM
194-240-304-385-498 Wet CFM
Heating . .... . ..... .. . .. . . .230-275-339-431 -512 CFM
ACCESSORIES Sound Pressure Level(Quiet-Lo-Med-Hi-Super Hi)
Indoor Unit Cooling . .. .. . .. . . . . . . .. . . . .. . . 28-33-38-44-49 dB(A)
❑ Condensate Pump(230V;SI3100-230) Heatin 28-33-38-43-49 dB A
g . . . .. . . . . .. . . . .. . . . .. . . ( )
Controller Options
❑ Wreless Wall-mounted Remote Controller Kit(MHK1)� DIMENSIONS UNIT INCHES I MM
❑ Portable Central Controller(MCCH1)' W 31-7/16/799
❑ OutdoorAirSensor(MOS1)` D 9-1/8/232
n Wired Wall-mounted Controller
(PAR-31 MAA requires MAC-3331F)' H 11-5/8!295
❑ Simple MA Remote Controller Weight.. .. .. . .. ... . . . ... . . .. . . . . . . . .. . .22 Ibs./10 kg
(PAC-YT53CRAU requires MAC-3331F)* E�ernal Finish . ... . . .. . .. . . . .. .. . . Munsell No. 1.OY 9.2/0.2
*See Submittal for information on each option. Field Drainpipe Size O.D.. .. . . . ..... .. . .. .... 5/8"/15.88 mm
u System Control Interface(MAC-3331F)
❑ Remote Temperature Sensor(M21-JKO-307) Refrigerant Type. . . .. . .. . .... . .... . . . .. . .... . ... . . R410A
u Lockdown Bracket for Hand-held Controller(RCMKPI CB) Refrigerant Pipe Size O.D.
Gas Side.. . ..... . .. .... . .. . .. ... .. . .... . 1/2"/12.7 mm
Liquid Side. . ... . .. . .. .. . . ... . .... ... . .. . . 1/4"/6.35 mm
Connection Method . . . .. .. . . .. . .... . . . ... ... . . .. . . .Flared
- ax � I ER R
Specifications are subject to change without notice.
OO 2015 Mitsubishi Electric US,Inc.
f� � .
� MITSUBISHI �� .�-��; d�
/_ ELECTRIC ( � 1 �-dr�y{ ���!�-- E R I E
C O O L I N G & H E A T I N G M S S
� 1
� ��� c ���- •- •
Job Name:
System Reference: Date:
SPECIFICATIONS
Cooling Capacity*. .... . . . . .. . . . .. . . . .. . .... . . .8,400 Btu/h
� � Heating Capacity at 47°F* . .. . . ... . .... . .... . ..10,900 Btu/h
'� 'Rating Conditions perAHRI Standard
���� ���� Cooling�Indoor:80°F(27°C)DB/67°F(19°C)WB
- , Cooling�Outdoor:95°F(35°C)DB/75°F(24°C)WB
Heating at 47°F�Indoor:70°F(21°C)DB/60°F(16°C)WB
S�z-KA09Na Heating at 47°F�Outdoor:47°F(8°C)DB/43°F(6°C)WB
(For data on specific indoor units[all ducted,all non-ducted,
and both ducted and non-ducted]combinations,see the MXZ
GENERAL FEATURES Technical and Service Manual.)
• Four-way 2'x2'ceiling-cassette indoor unit for ceiling recessed
applications Electrical Requirements
• Built-in drain mechanism for condensate removal;lifts to Power Supply. . . .. . . . . . . .. . . . . . . .208/230V, 1-Phase,60 Hz
19-11/16" MCA. ... . . .. . . . .. . . . . . . .. .. . .. . .. . .. .. . . . .. ... .... 1 A
• Wide air-flow pattern for better air distribution Voltage
• Design features ventilation air intake knockout Indoor-Outdoor S1-S2 . . ... . .. ... . . .. . . .. .. . AC 208/230V
• Long-life air filter included with indoor unit Indoor-Outdoor S2-S3 . . . ... .. . .. . . ... . . . .. . . . .. .DC t24V
• Indoor unit powered from outdoor unit using A-Control Fan Motor ECM 0.23 F.L.A.
• Choice of fan speed:Low,Medium,High � � """ " ' ' �" " ' " '� ' "
• Automatic restart foliowing a power outage Airflow Lo-Med-Hi 280-320-350 D CFM
Limited warranty:five years paRs and seven years compressors � � �� � � � 250-290-320 Wet CFM
ACCESSORIES Air Filter . .. .. .. . . .. .. . . . .. . .. . ...Polypropylene Honeycomb
Indoor Unit
o Grille(SLP-15AAUW;required-shipped with unit) Sound Pressure Level(Lo-Med-Hi) . . . .. . . . .29-32-38 d6(A)
Controller Options DIMENSIONS UNIT INCHES/MM GRILLE INCHES/MM
❑ Wireless Wall-mounted Remote Controller Kit(MHK1)'
❑ Portable Central Controller(MCCH1)' W 22-7/16/570 25-5/8/650
❑ OutdoorAir Sensor(MOS1)* D 22-7l16!570 25-5/8!650
❑ Wired Wall-mounted Controller(PAR-31 MAA)` H 9-1/4/235 13/16/20
❑ Simple MA Remote Controller(PAC-YT53CRAU)'
'See Submittal for information on each option. Weight(UniUGrille)
❑ Remote Temperature Sensor(M21-JKO-307) Lbs... . . .. . .... . .. . .. . . . ... . . .. . . . .. . ... . . .. . ... 36/7
❑ Hand-held Wireless Remote Controller 16.5/3
kg. .. . . . :. . .... . .. .. . . . . . . .. . . . . . . .. . ..
(PAR-FL32MA;req.PAR-FA32MA-E) External Finish(Unit/Grille) . .. .. . ... . Galvanized-steel Sheets/
❑ Wireless Signal Receiver PAR-FA32MA(for PAR-FL32MA) Munsell 6.4Y 8.9/0.4
❑ Lockdown Bracket for Hand-held Controller(RCMKPICB) Field Drainpipe Size O.D.. . . ..... . .. . . . .. . . . . . 1-1/4"/32 mm
Refrigerant Type... ... .. . . . . .... .. . . . .. . ... . . .. . . ..R410A
Refrigerant Pipe Size O.D.
Gas Side . .. .. . ..... . . . .. .. ... .. . ....... . 3/8"/9.52 mm
Liquid Side. . ... . .. . .. .. . ... .... .. . .. . .... 1/4"/6.35 mm
Connection Method ... .. . .. . .... . .. ... .... . ..... . . .Flared
' j � t I ER R
���
Specifications are subject to change without notice.
OO 2014 Mitsubishi Electric US,Inc.
r �
PLUMBING SYSTEMS INC. Master License 185796
PO Box 3879,Avon, Colorado 81620—970.390.7763 Cell
���� 970.926.0500 Office—970.569.3209 Fax
P€u�„31���Jf,tp�q�rerr�,!,t[t�.
Bid Proposal
Date: August 19, 2015
Client/Owner: LuLuLemon
Project Address: 193 Gore Creek Drive
Vail, CO 81657
Proposal: Multi-Zone AC
Bid By PSI Tech: Tom Johnson
Description of Work:
We propose to furnish labor and material for plumbing—complete in accordance with the below
specifications as follows:
Provide and Install one (1)outside condenser Mitsubishi Model MXZ-5C42NA with two(2) indoor
Mitsubishi Model MSZ-GEI8NA-9_For_MXZ_MULTI-ZONE_SYSTEMS in sales area and one(1) Mitsubishi
Model SLZ-KA09NA_For MXZ_MULTI-ZONE_SYSTEMS in Store Room/Office.These units are to be
complete with remote controls mounted on wall areas.
Outdoor Condenser unit to be installed on rack mounted to wall outside of electrical supply in storage
room.Wires and piping to be routed inside building within 4 feet of condensing unit,with the exception
of the electrical and refrigerant piping to front of store.This piping and electrical is to be routed high on
exterior wall and penetrate thru wall at or near stone veneer.This routing should eliminate any possible
exposure to asbestos. Ir�the event af ex�asing as�aestc�s, all wc�rl<shall stop and asbes�as abatemer�fi
sha�i begin by r�thers,�c�a pcsif�t where wc�rk can continue.
Most Interior work shall be performed overnight to prevent interference with store operation.
This Proposal i��cl��des all taxes permit fees and electrical work.
General Material Specifications: Interior Work:All drain waste and vent lines to be Schedule 40 PVC
pipe. All water lines to be Type M copper. Gas pipe to be Schedule 40 black steel and corrugated
stainless steel (CSSj.
Excluded from this Proposal:
This Bid does not include any line voltage wiring, concrete cutting and removal, concrete replacement or
patching, all roof penetrations, all roof repairs,testing, abatement, or disposal of Icad paint, asbestos,
mold or other hazardous materials,site utilities, excavation, mounting under mount sink, and permit
fees to be billed on separate invoices. This Bid does not include carbon monoxide detectors,fixtures or
faucets. This bid does not include any tasks or materials not specified in the Description of Work as
stated above.
LULUIEMON-MULTIZONE AC INSTALL.DOC
Price: The price for the above Description of Work is the sum of Thirty-Nine
Thousand Seventy($39,070).
Payment Terms: Payments will be made as follows:
Depasit of 50 percent(%)and Final Completion of 50 percent(%).
Unpaid balances after 15 days after each phase of completion will be charged an additional
administrative fee of 2 percent(%j per manth. Unpaid balances after 60 days of each phase af
campletion will be charged an additional interes#fee of 8 percent(%) per annum,compounded
annually. In the event of collection for non-payment with or without suit, PSI shall be entitled to recover
all collection costs and attorneys'fees,
Additional Terms and Conditions:
1. Plumbing Systems Inc. is not responsible forthe discovery of improperorfauity plumbing; rusted or
defective pipes;acids in drain systems;lines that are settled or broken;existing iliegal conditions;
defective roofing;and/or defective electrical.
2. All material is guaranteed to be as specified, A!I work to be completed in a worlcman-like manner
according to standard practices,
3. �'he price is based on the scope of wark listed above, Any additional work will be priced as a Change
Order.
4. The price is based on work being completed during normal business hours and does not account for
overtime hours. Any request by Client/Owner to complete worl<during overtime hours will be
priced as a Change Order.
5. All changes,additions, extras and/or deductions will be based on a fixed price and agreed to in
writing as a Change�rder before being incorporated into the project for both parties' protection.
6. This proposal is good for thirty{30}days.
7. All agreements are contingent upon strilces,accidents,or delays beyand our contral.
8. Owner to carry fire,tornado,and other necessary insurance.
9. The contractor will excavate aIl main line trenches for underground. If jackhammer and/or other
mechanical devices are required to break rock in orderto install underground plumbing,an
additional charge may be added to cover the cost of the additionaf labor and/or rental of said
equipment.
10. Please note that al!mechanical parts can and will fail. It is the responsibility of the homeowner or
building agent to protect his or herself from property damage by maintaining cold air sensors and/or
a flood mitigation device or both.
Acceptance of Proposal:
7he above prices,specifications,anc!conditions are satisfactory and hereby accepted.You are
authorized Yo do work as specified. Payment will be made as outtined above.
(�•2� • ��
Signature Date of Acceptance
�12��..,fT- L�Tc:��
Printed Name
LULULEMON-MULTiZONE AC)NS7pLLDOC
� � � � �
�� 4 I
i—-',
� ;
;
,4�. ,��
, �
; �
' %� %//
\� ",.- �� ��
4'
2' 1%"X 3/16"angle
Z��
�2�
2�
Page 1