Loading...
HomeMy WebLinkAboutB14-0043 Blower Door Report ���.������'��� �������#��.���i���6.vA A83�. Lion's Ridge Apartments — Building 2 Final Blower poor Report Test Date: September 18, 2015 Builder: Gorman & Company, Inc. Contact: Chuck Collins, RA Nelson Site Address: North Frontage Road, Vail, CO Site Visit By: Kristen Hartel Report By: Kristen Hartel Background The project goal is to undergo testing at final construction to determine if the project meets code requirements for air leakage (3ACH50). Code requirements allow for either pressurization or depressurization to be used when determining code compliance. All units were tested utilizing both pressurization and depressurization. The results from pressurization were consistently preferable over depressurization. ACH50 results as determined by pressurizing each unit are listed below. Site Observations To comply with RESNET sampling protocol, testing was completed on 10 randomly-chosen units in a variety of conditions (i.e. firewall, unit type, and number of exterior walls). Outside air temperature during the test was approximately 55°F. Construction was finished. All windows were installed and latched shut. The blower door test was performed in the entrance door to the units. Air Leaka e Results Unit Number Unit Type Unit Conditions CFM @ 50 Pa ACH 50 2102 D No firewall 365 2.97 2103 C Firewall 325 2.71 2204 D Firewall 320 2.6 2201 A No firewall 360 4.42 2302 D No firewall 485 3.94 2304 D Firewall 395 3.21 2105 C Firewall 250 2.08 2108 E No firewall 250 2.38 2208 E No firewall 280 2.23 2305 C Firewall 365 3.04 Please call with any questions or concerns. ��-�stew �ta�te� ��o-�o�--���� K��stev�@�Fct�ve�v�,er��es.cowt Page 1 of 1 9/22/2015 P.O. Box 7627,Avon, CO 81620 � P: 970.306.4233 � F: 866.403.3485 � www.activeenergies.com