Loading...
HomeMy WebLinkAboutB15-0273 plans approved VAIL , CO BUILDING PERMIT SET ^ 2 �� / ) /- '�` CONSTRUCTION NOTES: )L� A. CONTRACTOR SHALL VERIFY ALL DIMENSIONS CONFIGURATIONS AND J. CONTRACTOR IS TO COORDINATE CONSTRUCTION WITH ARCHITECT AND SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCIES BETWEEN THESE oWNER. CODE DATA DRAWINGS AND ACTUAL FIELD DIMENSIONS. - B. FIELD-VERIFIED ELEVATIONS AND DIMENSIONS OF EXISTING BUILDING E SHALL HAVE PRECEDENCE OVER ELEVATIONS AND DIMENSIONS SHOWN ON THE PLANS. WHEN A CONFLICT ARISES BETWEEN ELEVATIONS OR . DIMENSIONS SHOWN ON THE PLANS, THE CONTRACTOR SHALL NOTIFY � SBSA IN WRITING WITHIN 24 HOURS FROM THE TIME THE CONFLICT IS NOTICED. C. ALL ITEMS OF WORK SHALL BE ACCOMPLISHED IN A WORKMANLIKE MANNER, AND IN ACCORDANCE WITH BEST MODERN CONSTRUCTION PRACTICE. ALL MATERIALS, EQUIPMENT AND WORK SHALL COMPLY WITH ALL CURRENTLY APPROVED OR ACCEPTED PROVISIONS OF APPLICABLE CODES AND STANDARDS, AND ALL FEDERAL, STATE, COUNTY, AND MUNICIPAL CODES, LAWS, AND ORDINANCES. SUCH CODES, STANDARDS, LAWS, AND ORDINANCES SHALL, UNLESS OTHERWISE MUTUALLY AGREED UPON, BE THOSE THAT WERE IN EFFECT ON THE DATE OF THE BID OPENING. D. CONTRACTOR SHALL MAKE MAXIMUM EFFORT TO PERFORM ALL WORK IN THE LEAST DISRUPTIVE MANNER AND MAINTAIN A SAFE ENVIRONMENT DURING CONSTRUCTION. BARRICADES AND CONTROLS SHALL BE ERECTED AND MAINTAINED BY THE CONTRACTOR UNTIL COMPLETION OF PROJECT. E. ALL EXISTING UTILITIES SHALL BE PROTECTED AND ALL DAMAGES TO LANDSCAPING SPRINKLERS, UTILITIES, OR OTHER EXISTING STRUCTURES AS A RESULT OF CONSTRUCTION SHALL BE RESTORED TO ORIGINAL CONDITION EXCEPT WHERE MODIFICATIONS ARE NOTED. F. THE CONTRACTOR IS RESPONSIBLE FOR LOCAL TRAFFIC AND PEDESTRIAN CONTROL AND SITE SAFETY AND SECURITY. RESETTING OF SIGNS SHALL INCLUDE THE TEMPORARY RESETTING OF SIGNS NECESSARY FOR TRAFFIC AND PEDESTRIAN REGULATION(CAUTION SIGNS,ETC.) G. AT TIMES OF EQUIPMENT EMPLOYMENT, THE CONTRACTOR SHALL EMPLOY FIELD PERSONNEL TO AID IN GUIDING PEDESTRIAN TRAFFIC SAFELY AWAY FROM THE WORKING AREA. THE AUDIO SIGNALS OF ALL CONSTRUCTION MACHINERY SHALL BE IN WORKING ORDER DURING THE CONSTRUCTION. H. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL NECESSARY BUILDING PERMITS. I. CONTRACTOR SHALL ESTABLISH A WRITTEN SCHEDULE OF CONSTRUCTION AND REVIEW SAID SCHEDULE WITH ARCHITECT AND OWNER FOR APPROVAL. K. THE ARCHITECT SHALL RETAIN RIGHT TO APPROVE OR REJECT ALL WORK PERFORMED. L. CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY BUILDING DETERIORATION NOT SPECIFICALLY ADDRESSED BY THESE DRAWINGS BEFORE CONTINUING WITH THE WORK. M. CONTRACTOR SHALL HAVE SALVAGE RIGHTS, UNLESS SPECIFIC ITEMS ARE NOTED TO BE RETAINED BY THE OWNER. N. CONTRACTOR SHALL REMOVE ALL EQUIPMENT, UNUSED MATERIAL, AND DEBRIS FROM THE PREMISES AND LEAVE THE SITE IN A NEAT AND CLEAN CONDITION. GENERAL NOTES: A. THE ARCHITECTURE AND ENGINEERING SERVICES PROVIDED BY SBSA INVESTIGATION WERE LIMITED TO THE REVIEW AND EVALUATION OF SPECIFIC AREAS OR ITEMS WHICH WERE VISIBLE DURING OUR SITE VISITS OR AGREED UPON BY THE OWNER. OUR RECOMMENDATIONS ARE BASED ON PROBLEMS WHICH ARE EVIDENT AT THE PRESENT TIME. NO ASSURANCES CAN BE MADE THAT THE PROPERTY WILL NOT SUSTAIN FURTHER DAMAGE AFTER ANY REPAIRS ARE PROVIDED. B. THE REMODELING, REHABILITATION, AND/OR MODIFICATIONS OF AN EXISTING STRUCTURE REQUIRES THAT CERTAIN ASSUMPTIONS BE MADE REGARDING EXISTING AND PRE-EXISTING CONDITIONS. BECAUSE SOME OF THESE ASSUMPTIONS MAY NOT BE VERIFIABLE WITHOUT EXPENDING ADDITIONAL SUMS OF MONEY OR DESTROYING OTHERWISE ADEQUATE OR SERVICABLE PORTIONS OF THE BUILDING. THE CLIENT, BY THE ACCEPTANCE OF THE DRAWINGS AND DESIGN SPECIFICATIONS FOR THOSE PORTIONS OF SERVICES RENDERED, AGREES, TO THE FULLEST EXTENT PERMITTED BY LAW, TO INDEMNIFY AND HOLD THE ARCHITECT/ENGINEER HARMLESS FROM ANY CLAIM, LIABILITY OR COST (INCLUDING REASONABLE ATTORNEYS' FEES AND COST OF DEFENSE) FOR INJURY OR ECONOMIC LOSS ARISING OR ALLEGEDLY ARISING OUT OF THE PROFESSIONAL SERVICES PROVIDED. EXCEPTING ONLY THOSE DAMAGES, LIABILITIES, OR COSTS ATTRIBUTABLE TO THE SOLE NEGLIGENCE OR WILLFUL MISCONDUCT OF THE ARCHITECT/ENGINEER. SCOPE OF WORK: WATERPROOFING REPAIRS ON THIRD AND FOURTH LEVEL EXTERIOR DECKS. NO ALTERATIONS TO ANY STRUCTURAL OR FIREPROOFING SYSTEMS ON THE DECKS,AND NO REVISIONS TO THE ORIGINAL STRUCTURAL DESIGN. ��: ��_ Q ��'; "s.�, in � , ..'r,,, M �� •5 zy'1� �...����r.:; � �° l�j ,t,��_''; •� T�i J � N �� L � � Q � J U') APPLICABLE CODES: ORIGINAL CONSTRUCTION: -2003 INTERNATIONAL BUILDING CODE -2002 NATIONAL ELECTRICAL CODE -2003 INTERNATIONAL MECHANICAL CODE -2003 INTERNATIONAL PLUMBING CODE -2003 INTERNATIONAL ENERGY CONSERVATION CODE -2003 INTERNATIONAL FUEL GAS PIPING CODE -2003 INTERNATIONAL FIRE CODE REPAIR/REHABILITATION: -2012 INTERNATIONAL BUILDING CODE -2011 NATIONAL ELECTRICAL CODE -2012 INTERNATIONAL MECHANICAL CODE -2012 INTERNATIONAL PLUMBING CODE -2012 INTERNATIONAL ENERGY CONSERVATION CODE -20121NTERNATIONAL FUEL GAS CODE -2012 INTERNATIONAL FIRE CODE OCCUPANCY: PARKING GARAGE S-2 RESIDENTIAL UNITS R CONSTRUCTION CLASSIFICATION: PARKING GARAGE(S-2) TYPE IA RESIDENTIAL UNITS(R) TYPE VB LIVE LOADS USED IN ORIGINAL DESIGN: EXTERIOR DECKS(SNOW) 100 PSF LIVE LOADS USED IN REPAIR DESIGN: EXTERIOR DECKS(SNOW) 100 PSF II II IMi I_�� Solutions Before Solutions After aeaor,mPmo�,�m a��e,u�u iro c�iam,m wwm Ph:(3N�425JZR FaR:(1207365m5o �•;w.>.a ne��a...w ma a.n. w msi.iM.in.r mer�w e.a�p�ra. +�m�na.iu�wt m..wawa.num mv�xK.wpyiy�e ma nxny.�rot.r n. z � � < O � � � H � � Q W � Q � z � W O � 3 � c�n Wp � � � HU � �" O H � � � U � � � � � z � o � � x � � DRAWING SCALE: �"=1'-0" JOB NUMBER: 314037.00 COVERSHEET G1.01 � S � � 8 � � i ! �� �� E� �''� i�. � �?� � � A2.03 — STORAGE 2' CLOSET 1 ASSUMED EXISTING q2,p2 HYDRONIC LINES' . � S�F CV i �q 1 A2.03 1 2,_Q�� ASSUMED EXISTING �'�� SLOPE HYDRONIC LINES* n'P. —� EXISTING D N LOCATION 2�_��� LSLOPE` w � 0 o I EXISTING TIMBER COLUMN CV �� 2 EXISTING DRAIN oQ� o a A2.02 �LOCATION s�/ � o (V �1 � � SLOPE o a� EXTENT OF TAPERED DECK 2 N o AREA.REFER TO DETAILS. q2,01 �' TAPERED SLOPE= Yz"PER rYp. FOOT 2�_��� 'EXISTING HYDRONIC LINES TO BE SPLICED WITH PLASTIC NIPPLE CONNECTIONS IN LIEU EXISTING RAIL BALLUSTERS OF COPPER. LINES TO BE SLEEVED THROUGH EXISTING TIMBER BEAMS BELOW WALL AND TAPER PENETRATIONS WITH METALLIC PENETRATION SLEEVES.WATERPROOFING OF PENETRATIONS PER MANUFACTURER'S LEVEL 4 BALCONY RECOMMENDATIONS. SCALE: 1/4" = 1'-0" €�-y��'� A �' �' � �( , �_ ��- � L. 1 I A1.01 I CHALET 1 - LEVELS 3 AND 4 SCALE: 1/4"=1'-0" � <V A2.01 IW �� EXISTING DRAIN� LOCATION SLOPE � 1 1 � A2.02 :��:--_ Q . , �� � -'�,a...::.....:y�.: �;� �u;,� (+�1 Solutions Before �s�r�`�.,-:=? � Solutions After 6-��. 4fifl0 Table Noun�ain Drive,llni�1>0 Os� �\�' (n Cnldm,LOro1W ��•••...L.;��.L'/ .3 lt1 *;:.:_`: �""� r�.�303�azsanz O r...�nol3vsmso J N �,�«, ��"�:�m m.u,mm�o�..,,�,���. �,�����. �� NtlosU.a T�e!MUwut qr npwM wittm ..n ar msA nc cwrM�ma n/mw�m�e. � � �.a ow we..e�e.e. L SLOPE � Q \ J (!') A2.01 TYP. NOTE:ACTUAL LAYOUT MAY BE REVERSED. LEVEL 4 BALCONY SCALE: 1/4" = 1'-0" � � 0 < 0 � wa S�F �m �lA2.02 �° 2'-0" � 1 A2.03 SLOPE �,P EXISTING DRAIN LOCATI ON EXISTING TIMBER COLUMN SLOPE ❑ wi a � o � NOTE:ACTUAL LAYOUT MAY BE REVERSED. LEVEL 3 BALCONY SCALE: 1/4" = 1'-0" 2'-0" 2 A2.02 0 (V SLOPE A2.01 TYP. a � � � � � � W � w � z � Q � z � p � 3o � '� � w a � �U Q � H �� � w � � � � � � � � U � Q x � u DRAWING SCALE: %"=1'-0„ ]OB NUVIBER: 374037.W CHALETI-LEVEL53&4 A1.01 � � 0. Z 8 � < � $ NOTE:ACTUAL LAYOUT MAY BE REVERSED. LEVEL 4 BALCONY L-U EXISTING RAIL BALLUSTERS EXISTING TIMBER BEAMS BELOW LEVEL 4 BALCONY SCALE: 1/4" = 1'-0" 'EXISTING HYDRONIC LINES TO BE SPLICED WITH PLASTIC NIPPLE CONNECTIONS IN LIEU OF COPPER. LINES TO BE SLEEVED THROUGH WALL AND TAPER PENETRATIONS WITH METALLIC PENETRATION SLEEVES.WATERPROOFING OF PENETRATIONS PER MANUFACTURER'S RECOMMENDATIONS. � ��� � � ) �� % � � TYP. NOTE:ACTUAL LAYOUT MAY BE REVERSED. LEVEL 3 BALCONY SCALE: 1/4" = 1'-0" 1 I A1.02 I CHALET 2 - LEVELS 3 AND 4 SCALE: 114"=1'-0" � a � M 01 � � �� ,"I W O J N ^Y 1 L � � Q � � J (!) Solutions Before Solutions After aaea r.me m��m�m o.;..:,u�u i� c.�aa�,maoun Ph(303�425JZ12 Fax:(]20�345pt5p COP1fipIT ��„m F�lrumnl ol xrice md ve Me EMarO.a�Rr�t�ilUw�q�epwy 1wMn man 1 0l�Fc CapylqAh mE Flfiqsnnb M b mrt.e me�t.a. 0 � �0 � '< � a � �i a � o $ �m �m 0 � � � � a � OHaQ � Q � � ¢ Q � � � � O � °oW a � � �,W'' QUQwa E� � ¢ `� E� � � 3a � � � � � � � � U � ¢ x � U DRAWING SCALE: y"=7'{I" ]OB NU�IBER: 3]4D37.00 CHALET 2-LEVELS 3&4 A1.02 � z � A2.03 = STORAGE 2' CLOSET 1 2�_0�� ASSUMED EXISTING �'�� SLOPE HYDRONIC LINES" TYP. -_ 1 ASSUMED EXISTING q2.p2 HYDRONIC LINES* . � s�F N � �1 A2.03 �EXISTING DF2AjN Typ, LOCATION I 2'-0" LSLOPE` w � 0 o yI EXISTING TIMBER COLUMN CV �1 z EXISTING DRAIN oQ� o a A2.02 �LOCATION s�/ N �� C � - SLOPE EXTENT OF TAPERED DECK 2 N �� AREA.REFER TO DETAILS. q2,01 `� TAPERED SLOPE=Yz"PER Typ. FOOT 2�_0�� *EXISTING HYDRONIC LINES TO BE SPLICED WITH PLASTIC NIPPLE CONNECTIONS IN LIEU EXISTING RAIL BALLUSTERS OF COPPER. LINES TO BE SLEEVED THROUGH EXISTING TIMBER BEAMS BELOW WALL AND TAPER PENETRATIONS WITH METALLIC PENETRATION SLEEVES.WATERPROOFING OF PENETRATIONS PER MANUFACTURER'S LEVEL 4 BALCONY RECOMMENDATIONS. SCALE: 1/4" = 1'-0" 6 ,- 1 I A1.03 I CHALET 3 - LEVELS 3 AND 4 SCALE: 1/4"=1'-0" C�/� �/ ) / / /rl�- ) � � <V A2.01 �W a O EXISTING DRAIN� LOCATION SLOPE � � 1 A2.02 Q S�,o��N�"-:iy,'�. I� �:.s;�� �'�;. M Solutions Before ;;1�; w� � Solutions After �n�:?:.,,,�,"��;; nseo r,mo Mo�,�m o.�.e,u�u,�o ,O �..L' � �f'] coie�,cnaam �'..>>�P. .- ,� � �,.�3�i�-�m e..:pzol�wzso � mvnnwr J N TM..��,m�.�.,�a..�.,�,.a. a�.,a�.M�.�.��„�a.�wr,� can�n p�M���IU 1 qe apeeeJ wlWn �u'1 �«n�m�;:e,�b""'�ae ti.���u..a L � � � T„-- J (n �.�� TYP. NOTE:ACTUAL LAYOUT MAY BE REVERSED. LEVEL 4 BALCONY SCALE: 1/4" = 1'-0" z 0 a 0 �m 1 a S�F �m �1 A2.02 �� 2'-0" � 1 A2.03 SLOPE TYP. EXISTING DRAIN LOCATION EXISTING TIMBER COLUMN SLOPE � W1 a I ° N NOTE:ACTUAL LAYOUT MAY BE REVERSED. LEVEL 3 BALCONY SCALE: 1/4" = 1'-0" 2'-0" 2 A2.02 0 CV SLOPE A2.01 TYP. �--� � � � � W �r w � w � z � Qc� � � � 03ow �l � � W � OQ � .� � H � E"'� f-�"'�i � � W � ¢ � � ¢ � � � U � �' x � u oR.av�NC scnLe: y,�=i.�, JOB NU,VIBER: 374037.W CHALET 3-LEVELS 3&4 A1.03 � 8 g a 8 � m $ L�V EXISTING RAIL BALLUSTERS EXISTING TIMBER BEAMS BELOW LEVEL 4 BALCONY SCALE: 1/4"= 1'-0" 1 I A1.04 *EXISTING HYDRONIC LINES TO BE SPLICED WITH PLASTIC NIPPLE CONNECTIONS IN LIEU OF COPPER. LINES TO BE SLEEVED THROUGH WALL AND TAPER PENETRATIONS WITH METALLIC PENETRATION SLEEVES.WATERPROOFING OF PENETRATIONS PER MANUFACTURER'S RECOMMENDATIONS. �`� 1 � � t`�'1� � '� CHALET 4 - LEVELS 3 AND 4 SCALE: 1l4"=1'-0" NOTE:ACTUAL LAYOUT MAY BE REVERSED. LEVEL 4 BALCONY � TYP. NOTE:ACTUAL LAYOUT MAY BE REVERSED. LEVEL 3 BALCONY SCALE: 1/4" = 1'-0" � Q n M /� � V/ IA I.J 1 •� � W O J N �� L � L � Q .� � J (n Solutions Before Solutions After 4fiB0 Table 1iow�sin Ihive,Unit 1J11 Gnidm,fOBpCN Ph(30.iJ 425JD1 Faz:(I2UJ345U}.50 Ni m�i�y m m n�Wmnt M rrNCe md nre qe ol�5/�F�.T�er mpy ml be ypliM�l. �ai�n �i�m.aw�...a..me� i ma n��.a. �ny.�e wie. z c � � � 0 �m �m 0 a � � � � � � W � w � z � Q cn � � � O30w a � � ,,W`� �UQWa E� � � 3 � w � � � � x w g � a Q x � U ORAWING SCALE: %"=1�{7^ �oa NuHaea: s�ao3�.ou CHALET 4-LEVELS 3&4 A1.04 � � 8 a a � a � 0 u � m � A2.03 STORAGE CLOSET 1 ASSUMED EXISTING p,Z,p2 HYDRONIC LINES" I s`„� ��A ,� N �1 li / A2.03 EXISTING D N � 2�-0�� nP, LOCATION 2�_��� ASSUMED EXISTING �'�� SLOPE HYDRONIC LINES* rvP. -- L SLOPE w ~ 0 o I EXISTING TIMBER COLUMN (V m+ 2 EXISTING DRAIN oQ� o a A2.02 LOCATION 5�/ � o � CV � � , I }b�l j I��I - SLOPE w EXTENT OF TAPERED DECK 2 ° o� AREA.REFER TO DETAILS. ,q2,01 N `� TAPERED SLOPE= Yz"PER rrP. FOOT 2�_��� *EXISTING HYDRONIC LINES TO BE SPLICED WITH PLASTIC NIPPLE CONNECTIONS IN LIEU EXISTING RAIL BALLUSTERS OF COPPER. LINES TO BE SLEEVED THROUGH EXISTING TIMBER BEAMS BELOW WALL AND TAPER PENETRATIONS WITH METALLIC PENETRATION SLEEVES.WATERPROOFING OF PENETRATIONS PER MANUFACTURER'S LEVEL 4 BALCONY RECOMMENDATIONS. SCALE: 1/4" = 1'-0" � Zi/ -_ � � ��,, % � 1 I A1.05 I CHALET 5 - LEVELS 3 AND 4 SCALE: 1/4"=1'-0" � CV A2.01 �W a O � EXISTING DRAIN- LOCATION SLOPE � 1 � � A2.02 �-<--_„R Q �s�� �� ����� � Solutions Before .,,..... ,,,� M �:•�� '•`y`t �° ��;:�� � Salutions After M+POTableMo�muinorive, iitlll ���s '.G'J��/J �' � � Go1drn,C08�1N[)n �.'.7�'... '.-Y�? ._. �3 � ��3�„�,m ea.:��zu�sas-mso J � �«:�,.m:,.�,��,�..:�.ma�.a. pep�M1Y el IDS4 Mc.1MY moY rol M M1+MkNM. ��.a�.,.� ��.�.�, i��i ���sasA mc cmrH��me nwnw���.M e. � �«�.��a,��° L � SLOPE � Q � ; 1 J � A2.03 A2.01 TYP. NOTE:ACTUAL LAYOUT MAY BE REVERSED. LEVEL 4 BALCONY SCALE: 1/4"= 1'-0" w� 1 0 A2.02 � 2'-0" � 1 A2.03 SLOPE �.P EXISTiNG DRAIN LOCATION EXISTING TIMBER COLUMN SLOPE I � Wi a O � NOTE:ACTUAL LAYOUT MAY BE REVERSED. LEVEL 3 BALCONY SCALE: 1/4" = 1'-0" S��p \F �W � 0 � 2'-0„ 2 A2.02 SLOPE ,�1 � A2.01 TYP. z � � � 8 x �i O � � o � $ �m � � � � H � W � w � z � � � � � Q zo � � aO � OW a � O � F � E--� � 6 3 W � � � zx W 0 U ,� a x � U DRAWI[JG SCALE: y"=7'{I" JOB NUVfBER: 374037.W CHALET 5-LEVELS 3&4 A1.05 " ASSUMED EXISTING HYDRONIC LINES' W� 0 m SLOPE 1 2'-0„ A2.�2 ASSUMED EXISTING HYDRONIC LINES' w a o �, `� N STORAGE CLOSET 1 1 A2.01 EXISTING DRAIN �•03 I I TvP. LOCATION TYP. 2 � � = A2.03 SLOPE wI � o I EXISTING TIMBER COLUMN (V �I SLOPE .�2 ~ �EXISTING DRAIN S�� o o� LOCATION N � SLOPE TYP. W EXTENT OF TAPERED 2 ° o} DECK AREA.REFER TO ,4z,01 N uJi� DETAILS.TAPERED SLOPE=Y"PER FOOT 2,_�„ *EXISTING HYDRONIC LINES TO BE SPLICED WITH PLASTIC NIPPLE CONNECTIONS IN LIEU EXISTING RAIL BALLUSTERS OF COPPER. LINES TO BE SLEEVED THROUGH EXISTING TIMBER BEAMS BELOW WALL AND TAPER PENETRATIONS WITH METALLIC PENETRATION SLEEVES.WATERPROOFING OF PENETRATIONS PER MANUFACTURER'S RECOMMENDATIONS. LEVEL 4 BALCONY SCALE: 1/4" = 1'-0" 1 A1.06 CHALET 6 - LEVELS 3 AND 4 SCALE: 1/4"=1'-0" � _ i 2 �� ; � �7� ,��. � � A2.01 NOTE:ACTUAL LAYOUT MAY BE REVERSED. LEVEL 4 BALCONY SCALE: 1/4" = 1'-0" 1 A2.02 2'-0" 1 A2.03 SLOPE EXISTING DRAIN LOCATION EXISTING TIMBER COLUMN SLOPE w � 0 � � � \s��A \F �w a O I � 2�'�n 2 A2.�2 I SLOPE 0 CV I A2.01 TYP. NOTE:ACTUAL LAYOUT MAY BE REVERSED. LEVEL 3 BALCONY SCALE: 1/4"= 1'-0" � � Q � M Solutions Before � Solutions After � acear,ni..MO��o���.��e,u�ni�o ,^ Go1dm,GD86103 Y 1 •�j T..� Ph:(3N)425-]TR > F..,�ZO,� JO N ��,�,��.�,��a.�..�ma,.�. v�w�nr vi�v,n�.my mey�e�e.ap'Ya.a. �� ame.a.a�w��.e.iaw�a.m.�«e.m�� � � mm«��oi mu n�.av�NU me�.e*v��.x e. r�.a me w.m�.e L � � J (n 'c � � a 0 �m �m 0 � � � � � � fsl � W � Z Q � � � � � � O w � OOQ � � � � 6 � �. H � � 3w � � � ox w u � ,..a a � � x � u � � a < 0. �C 0 m � DRAN7NG SCALE: y"=1{I" )OB NUMBER: 374037.00 CHALET 6-LEVELS 3&4 A1.06 l � � i i i . � � A2.03 STORAGE CLOSET 1 ASSUMED EXISTING p,2.p2 HYDRONIC LINES* � \s�oa . I \c� w a 0 0 CV �p 1 A2.03 1 2,_�,� ASSUMED EXISTING �'�� SLOPE HYDRONIC LINES* n'P• ~ EXISTING D N LOCATION 2�_0�� LSLOPEa o a I EXISTWG TIMBER COLUMN [V N� z A2.02 EXISTING DRAIN Q� o a LOCATION s�'� N �7 C � � = SLOPE w EXTENT OF TAPERED DECK 2 ° o� AREA.REFER TO DETAILS. p,2,01 (V � TAPERED SLOPE= Yz"PER nP. FOOT 2,_�„ *EXISTING HYDRONIC LINES TO BE SPLICED WITH PLASTIC NIPPLE CONNECTIONS IN LIEU EXISTING RAIL BALLUSTERS OF COPPER. LINES TO BE SLEEVED THROUGH EXISTING TIMBER BEAMS BELOW WALL AND TAPER PENETRATIONS WITH METALLIC PENETRATION SLEEVES.WATERPROOFING OF PENETRATIONS PER MANUFACTURER'S LEVEL 4 BALCONY RECOMMENDATIONS. SCALE: 1/4" = 1'-0" er 1 I A1.07 CHALET 7 - LEVELS 3 AND 4 SCALE: 1/4"=1'-0" �� I � � '.J / � � CV A2.01 1 W a O � EXISTING DRAIN- LOCATION SLOPE � A2.03 A2.02 � � � , Q �;� .;`�`,°.•-`""'�'.�Fy_ � Solutions Before ;;.:5. .,�. .. � _�i Solutions After �: �:�;L�., � q�.:� 4fiApTableMn�m�alnOrive.Unit1J0 b iI� f.nldm,C()&)i6i a .,� � 4 �n,'-�...Jc"c..�' v� � '� � en aos `� . � ��-�m �.-s-.�. � _ Fax.��z��� - O �,a„�,. J N ,�.�,.m�.���a.�.m<,.a. pJfd�oKUr�a rpoEutM NMwI Me apeexE wXlm ` �/� t al�SA Mc CopylpMS mE nlM1�q�m�nLL MI b �.Y 1 wbrtN md P��. L � � � �-� J UI A2.01 TYP. NOTE:ACTUAL LAYOUT MAY BE REVERSED. LEVEL 4 BALCONY SCALE: 1/4" = 1'-0" S : �� �� / : ��.� -;.+� 2'-0" � 1 A2.03 SLOPE 7YF EXISTING DRAIN LOCATION EXISTING TIMBER COLUMN SLOPE W a 0 I � NOTE:ACTUAL LAYOUT MAY BE REVERSED. LEVEL 3 BALCONY SCALE: 1/4" = 1'-0" � � � 0 a 0 �m S�F �m 2'-0" 2 A2.02 SLOPEC 0 N C 2 A2.01 NP. � � � � c W � W � Q cn . Q � zF � Q � � � � Q F � � E � � : H � � � � � x � U iQ ) � : �, ) � , W i � : Lj ; � ? u � 8 � � 0 a � � � DRAWING SCALE: �"=1'U" JOB NU�IBER: 374037.W CHALET 7-LEVELS 3&4 A1.07 L-U EXISTING RAIL BALLUSTERS EXISTING TIMBER BEAMS BELOW LEVEL 4 BALCONY SCALE: 1/4" = 1'-0" *EXISTING HYDRONIC LINES TO BE SPLICED WITH PLASTIC NIPPLE CONNECTIONS IN LIEU OF COPPER. LINES TO BE SLEEVED THROUGH WALL AND TAPER PENETRATIONS WITH METALLIC PENETRATION SLEEVES.WATERPROOFING OF PENETRATIONS PER MANUFACTURER'S RECOMMENDATIONS. � �. 1 I A1.08 I CHALET 8 - LEVELS 3 AND 4 SCALE: 114"=1'-0" NOTE:ACTUAL LAYOUT MAY BE REVERSED. LEVEL 4 BALCONY � TYP. NOTE:ACTUAL LAYOUT MAY BE REVERSED. LEVEL 3 BALCONY SCALE: 1/4" = 1'-0" � Q rn M � � � .3 r-I W O J N /�Y/ L � � a � � J (n Solutions Before Solutions After aswo r,me M�mm�on.e,v,,;i i�o c�ia�,m Pnam Ph(3Q9)�425-�D2 Fax:(]30)31S025p IGNi b�w o.m�.w��,r.,,�ma v.u. y or�e�.my moy�a e.apka.e. M.rc rproqi�M Mqwl q�+P�wMn �a�sA nc copyyrt.me Mma��.�M e. � c � � < 0 �m �m 0 a � � � � � W Q w � z � � � � � � 30w '� � w a H O Q 6 H Er-] � W -� �-+ �, 3 a � Q � � ¢� w � v � a a � ¢ x � U DRAWING SCALE: y"=1'-0" )OB NU�IBER: 374037.00 CHALET 8-LEVELS 3&4 A1.08 � � � < � a $ A2.03 — STORAGE 2' CLOSET 1 2�_�,� ASSUMED EXISTING �'�� SLOPE HYDRONIC LINES" TYP. 1 ASSUMED EXISTING q2.p2 HYDRONIC LINES" — . ! s�F CV i tp 1 1 A2.03 EXISTING D N nP. �LOCATION 2�_0�� W L SLOPE' 0 o I EXISTING TIMBER COLUMN fV v�� 2 EXISTING DRAIN � _ w A2.02 �LOCATION s�-� N �� t � SLOPE 0 0� EXTENT OF TAPERED DECK 2 N � AREA. REFER TO DETAILS. ,q2,01 TAPERED SLOPE=Yz"PER TyP. FOOT 2�_��� 'EXISTING HYDRONIC LINES TO BE SPLICED WITH PLASTIC NIPPLE CONNECTIONS IN LIEU EXISTING RAIL BALLUSTERS OF COPPER. LINES TO BE SLEEVED THROUGH EXISTING TIMBER BEAMS BELOW WALL AND TAPER PENETRATIONS WITH METALLIC PENETRATION SLEEVES.WATERPROOFING OF PENETRATIONS PER MANUFACTURER'S LEVEL 4 BALCONY RECOMMENDATIONS. SCALE: 1/4" = 1'-0" 1 I A1.09 I CHALET 9 - LEVELS 3 AND 4 SCALE: 1/4"=1'-0" -- �c� , .,;— � � � � A2.01 NOTE:ACTUAL LAYOUT MAY BE REVERSED. LEVEL 4 BALCONY SCALE: 1/4"= 1'-0" � W�A2.02 � 2'-0" � 1 A2.03 SLOPE TYP EXISTING DRAIN LOCATION EXISTING TIMBER COLUMN SLOPE ❑ wi a 0 � NOTE:ACTUAL LAYOUT MAY BE REVERSED. LEVEL 3 BALCONY SCALE: 1/4" = 1'-0" \s�oA �F � W a O � 2'-0" 2 A2.02 0 CV SLOPE A2.01 TYP. Q O� M Solutions Before � Solutions After �I� asen r,bir M„��um n.;�e,u�u i>o VI 1/1 Goldm,CU&yRA Y! •� � P!t(303J 425-�ZR n' O Fa�:(l2�)34SVL`A W COY1F1[11 J N �,�sa iM i�w��,�..�.�e�.a. �.no.a.a�cea.�m�ai a aamea�.m� i��i�i .�a..�e�m��`'�nH'�me v�xn���.e w i � � � J (n � 0 < 0 �m �m 0 � � � � � W �r (,�,� Q � � � Q � z � �, O � 3 � � � W ,��, � Q � a H � � � E"i ra-� � � W � � � � x W U U �-] � x � U DRAWING SCALE: �"=7{�,� JnB���: 374037.00 CHALET 9-LEVELS 3&4 A1.09 � � a `6 � 0 u � m � � w� a 0 � SLOPE 1 2'-0" � ASSUMED EXISTING HYDRONIC LINES* ,�.oz ASSUMED EXISTING HYDRONIC LINES' w a o Q cn (V STORAGE 1 CLOSET 1 A2.01 EXISTING DRAIN �•03 TYP. LOCATION TYP. 2 = A2.03 SLOPE w N �j EXISTING TIMBER COLUMN SLOPE EXISTING DRAIN oQ� o a� .02 �LOCATION s�/ N o � SLOPE TYP. o a� EXTENT OF TAPERED 2 ' o DECK AREA.REFER TO N `� DETAILS.TAPERED %�•01 SLOPE_�"PER FOOT 2�_��� *EXISTING HYDRONIC LINES TO BE SPLICED WITH PLASTIC NIPPLE CONNECTIONS IN LIEU EXISTING RAIL BALLUSTERS OF COPPER. LINES TO BE SLEEVED THROUGH EXISTING TIMBER BEAMS BELOW WALL AND TAPER PENETRATIONS WITH METALLIC PENETRATION SLEEVES.WATERPROOFING OF PENETRATIONS PER MANUFACTURER'S RECOMMENDATIONS. LEVEL 4 BALCONY SCALE: 1/4" = 1'-0" z y�� �-. ���� 1 I A1.10 I CHALET 10 - LEVELS 3 AND 4 SCALE: 1/4"=1'-0" ic (V A2.01 NOTE:ACTUAL LAYOUT MAY BE REVERSED. LEVEL 4 BALCONY SCALE: 1/4" = 1'-0" A2.02 2'-0" � A2.03 SLOPE EXISTING DRAIN LOCATION EXISTING TIMBER COLUMN SLOPE ❑ w� a � ° � \s�op \F IW �� 2'-0" 2 �.�2 SLOPE 0 (V A2.01 TYP. NOTE:ACTUAL LAYOUT MAY BE REVERSED. LEVEL 3 BALCONY SCALE: 1/4" = 1'-0" � Q � Solutions Before M � Solutions After afien rame nm,sm�ox.e u„��i�o � '^ Goldm,fOBp1N �, •� � Ph(303)425-1TR /�� Fax:(]20)X5CQ50 W O CCPM1fNT .� N m..aro.nw a.m n.wm„�w..w�.aa v.m. ww�r a�sA iM m.y ma nw e.mpKm�e. �.>,.�.,���.�..�M��., '`�i �a sssi,x�c wvr�d���ma Fm�mm�o a e. � �ac.a ma w���.a L � � � J (,!') � � � 0 � 0 �m �m �m 0 a � � � � c�, � � QWz �¢ � m � Q 3 p w � QQ � a ,�, E.. o � E� �� 3w H � � rx z o � a a � � x � U DRAWING SCALE: y"=1'-0" ]OB NUVBER: 374U3�.00 CHALET 10-LEVELS 3&4 A1.10 � � S a a 6 0 a m � L-U EXISTING RAIL BALLUSTERS EXISTING TIMBER BEAMS BELOW LEVEL 4 BALCONY SCALE: 1/4" = 1'-0" 1 I A1.11 *EXISTING HYDRONIC LINES TO BE SPLICED WITH PLASTIC NIPPLE CONNECTIONS IN LIEU OF COPPER. LINES TO BE SLEEVED THROUGH WALL AND TAPER PENETRATIONS WITH METALLIC PENETRATION SLEEVES.WATERPROOFING OF PENETRATIONS PER MANUFACTURER'S RECOMMENDATIONS. / Z_1�� 1 � ��. 1 � CHALET 11 — LEVELS 3 AND 4 SCALE: 114"=1'-0" NOTE:ACTUAL LAYOUT MAY BE REVERSED. LEVEL 4 BALCONY y TYP. I NOTE:ACTUAL LAYOUT MAY BE REVERSED. LEVEL 3 BALCONY SCALE: 1/4" = 1'-0" � Q 0 '�t 'I1 � V/ IA Y I �� 1"I W O J N �� L � Q� Q � � J (n Solutions Before 5olutions After 4b80 Table Mmmtein UivG Ilni�1]II Goldm,C(lA1WU 1'h(3N)425-�D1 Fax:(Y20)3450250 ]IT Ymwq�m m wWumml al�rt�ire mE m Ue a�„�m�,m%����. °oi ms�e�My,i.m�e n�im�•mm f ma�he. wn.n..x e. � c � � 0 a 0 �m 0 a � � � H � � F W � � C� 7 � Q � � O `� 003 � w � a W � � � U Q W � �' � E-� � ��., 3 w H � � zx o � ,..W_1 a x � U DRAN7NG SCALE: y"=1��1^ ]OB NUVIBER: 374037.W CHALET ll-LEVELS 3&4 A1.11 � � � S � < � a � 8 � � � 2'-0" 1 ASSUMED EXISTING �'�� SLOPE HYDRONIC LINES* TYP. ~ W 1 ASSUMED EXISTING /�.02 HYDRONIC LINES"` I \S�DA \� w li / a � O (V y A2.03 EXISTING D N np. LOCATION 2�_��� I SLOPE 0 o EXISTING TIMBER COLUMN � � CV �, 2 Z A2.02 A2.03 EXISTING DRAIN QE - a LOCATION S�'� N �1 � _ � STORAGE 2' 0' CLOSET PE SLOPE w EXTENT OF TAPERED DECK 2 — ° o} AREA.REFER TO DETAILS. ,q2,01 N `�� TAPERE P -Y" D SLO E- 2 PER TYP. FOOT 2�_��� *EXISTING HYDRONIC LINES TO BE SPLICED WITH PLASTIC NIPPLE CONNECTIONS IN LIEU EXISTING RAIL BALLUSTERS OF COPPER. LINES TO BE SLEEVED THROUGH EXISTING TIMBER BEAMS BELOW WALL AND TAPER PENETRATIONS WITH METALLIC PENETRATION SLEEVES.WATERPROOFING OF PENETRATIONS PER MANUFACTURER'S LEVEL 4 BALCONY RECOMMENDATIONS. SCALE: 1/4" = 1'-0" Z�j + � I �' 1 � � Z 1 A1.12 I CHALET 12 - LEVELS 3 AND 4 SCALE: 1/4"=1'-0" � (V A2.01 !W a 0 � EXISTING DRAIN� LOCATION SLOPE i 1 � � A2.02 �a;--:--, Q ��,o.,�;....�:3,; O �:•�� � �;�,+�� ••..r,,,• � Solutions Before o= `���$? � Solutions After ��'.,, Uy'] 4fi80Tab1eNo�m�ainOnve,unitilll �)� �� � Gnldrn,C08U1N �j� .}.,�,> LIi `�::�.� �. '3 ,� ��3�,�,m � .!:.."_� O Far.(J20)3LSpL`0 J N �„�r in...>a.�a�v.m�.w��oi...K.ma a.n. papetY ol 9il Inc.11ieY moY rot Aa dplkdM JftlasE.v�pe.lce0�IUwI M<cpeaN wMm �� cann�o�ms�.ec GvrMU me Fxnq.�wb.�e. � � n�.e m<o.e�na. L SLOPE � Q ,_ � 31 J � A2.03 A2.01 TYP. NOTE:ACTUAL LAYOUT MAY BE REVERSED. LEVEL 4 BALCONY SCALE: 1/4" = 1'-0" 1 al A2.02 � 2'-0" � 1 A2.03 SLOPE -ryp EXISTING DRAIN LOCATION EXISTING TIMBER COLUMN SLyPE � wl a � � NOTE:ACTUAL LAYOUT MAY BE REVERSED. LEVEL 3 BALCONY SCALE: 1/4" = 1'-0" S�F �w a O � 2'-0„ 2 �.�2 SLOPE � � A2.01 TYP. z � o � 8 a a 8 a m o ^ $ �� � � `� �> a �m � �� � a � � � E-" W �, � O � H W �] � � � � � Opzgw WQQ � a � U � N r E"'� � �+�, 3W � � � � � w � � � � a � Q x � u DRAWING SCALE: y"=1'-0" JOH NUNIBER: 374037.W CHALET 12-LEVELS 3&4 A1.12 L�V EXISTING RAIL BALLUSTERS EXISTING TIMBER BEAMS BELOW LEVEL 4 BALCONY SCALE: 1/4" = 1'-0" "EXISTING HYDRONIC LINES TO BE SPLICED WITH PLASTIC NIPPLE CONNECTIONS IN LIEU OF COPPER. LINES TO BE SLEEVED THROUGH WALL AND TAPER PENETRATIONS WITH METALLIC PENETRATION SLEEVES.WATERPROOFING OF PENETRATIONS PER MANUFACTURER'S RECOMMENDATIONS. � �� / � J� 1 A1.13 � CHALET 13 - LEVELS 3 AND 4 SCALE: 1/4"=1'-0" NOTE:ACTUAL LAYOUT MAY BE REVERSED. LEVEL 4 BALCONY � TYP. NOTE:ACTUAL LAYOUT MAY BE REVERSED. LEVEL 3 BALCONY SCALE: 1/4"= 1'-0" � Q � d' 0� N N •3 rl W O _I N �� L � � a � � J (n Solutions Before Solutions After nEeo rnme How�,;��;�e,u���i�o c�ia�,m emm Ph(3N�425-]DI Fa�:()2��345-02YJ ilI tc�n¢as m n�bum�l M urie me ae Me a«mom���a�..°ewn�ira�'.m� or mv,e�.woNPO ma nena�e w ee 1 ma woxat.a 7 CF E � a 0 �� 0 � � � � H � � � � F � �¢ wpW � C� � � �, Op � gw '� ,,,a 3 � w c. a ]„�W-' � C] w � �" � H F-ai �,�, 3 W H � � zx o � a a Q � x � U DRAWING SCALE: y"=1'-0" )OB NUMBHR: 374037.W CHALET 13-LEVELS 3&4 A1.13 � � � a � z � O u a a � � z � N z � 0 (E)EXTERIOR WALL CONSTRUCTION SHINGLE-LAP NEW BUILDING PAPER UNDER EXISTING LAYERS(MIN 2" LAP) BOARD AND BATTEN WOOD SIDING TO MATCH EXISTING CARRY WATERPROOFING UP WALL SURFACE 8"MIN FROM TOP OF SLAB WATER RESISTIVE BARRIER LAPPED OVER FLASHING/SCREED COPPER FLASHING WITH 4"VERTICAL LEG AND HEMMED EDGE NON-SKINNING BUTYL SEALANT RANDOM PATTERN STONE TO MATCH EXISTING "HYDRODRAIN 700"DRAINAGE MAT %"PLYWOOD DECK ON TAPERED 2x SLEEPERS HYDRONIC TUBING 6x6WWF "HYDORTECH"FLUID APPLIED WATERPROOF MEMBRANE AND CAP SHEET SELF-LEVELING URETHANE SEALANT %"ISOLATION JOINT FILLET SEALANT AT PERIMETER JOINT (E)STRUCTURAL SYSTEM AND DECK NOTE: WATERPROOFING TO CONSIST OF 90 MIL FIRST COAT FOLLOWED BY REINFORCING MESH,THEN SECOND COAT OF 125 MILS AND SECOND LAYER OF REINFORCING MESH. INSTALL PER MANUFACTURER'S INSTRUCTIONS 1 � A2.01 � TYPICAL PERIMETER BALCONY TRANSITION AT EXT. WALL SCALE: 3"=1'-0" �"PLYWOOD DECK ON TAPERED 2x SLEEPERS HYDRONIC TUBING 6 x 6 WWF "HYDORTECH"FLUID APPLIED WATERPROOF MEMBRANE AND CAP SHEET SELF-LEVELING URETHANE SEALANT %"ISOLATION JOINT FILLET SEALANT AT PERIMETER JOINT (E)STRUCTURAL SYSTEM AND DECK EXISTING RAILING BALLUSTERS, SEE ORIGINAL DETAIL 11A2.04 FOR ATTACHMENT "HYDORTECH"FLUID APPLIED WATERPROOFMEMBRANE OVER TOP SIDE OF EDGE FRAMING \ COPPER FLASHING CAP WITH HEMMED DRIP EDGE NON-SKINNING BUTYL SEALANT CARRY WATERPROOFING UP STEEL SUPPORT POST TO UNDERSIDE OF WOOD RANDOM PATTERN STONE TO MATCH EXISTING � "HYDRODRAIN 700"DRAINAGE MAT SLOPE 114"I FT. � / � � 1� � �� , %�=,� i -� (E)FURRING (E)T&G WOOD DECKING �,.-__ , ,,_�. SF,D:,..'M...,;� ��..��;;: �'; ' � w�j�� ��,'1 J ! �° ._�?3�•—.�. i ii� j $� __ � I I i < � � a� �� �` JJ � , .. � `' �, I � '.°'": _ : , NOTE: WATERPROOFING TO CONSIST OF 90 MIL FIRST COAT FOLLOWED BY REINFORCING MESH,THEN SECOND COAT OF 125 MILS AND SECOND LAYER OF REINFORCING MESH.INSTALL PER MANUFACTURER'S INSTRUCTIONS 2 � A2.01 � TYPICAL PERIMETER BALCONY TRANSITION AT RAIL EDGE SCALE: 3"=1'-0" Solutions Before Solutions After 46BO taFle Nn�mqin Dnve.Llnit iTl (%% Gnldm CO&N0 '� �,3�,,�,m F.,_(�20,345-W50 J �' mo av.nw a.m„.wmmi a�.a.k.ma s.u. �,��,.��,�.�m��,.��.� �, ��i o��n�:wMau�`a„°°*F°°.m,m � wr�.e me vo..a�.a. �u�a L � � J � � � o � � a a w z � I I I I I I� �� � � � H � C7Q � � Q � z w � O � OO � '� a3 � ¢ �, WO � � � U � � Q � � � z O � a x � U DRAWING SCALE: y"=7'.p" JOH NU�fB£R: 374037.IX1 DETAILS A2.01 i�. (E)DOORS-TEMPORARILY REMOVE FOR PROPER THRESHOLD FLASHING JAMB TRIM VERIFY PAN FLASHING AT THRESHOLD-PROVIDE IF MISSING COPPER FLASHING BEYOND SELF-ADHERED MEMBRANE FLASHING AT THRESHOLD-LAP OVER WATERPORRFING � RANDOM PATTERN STONE TO MATCH EXISTING "HYDRODRAIN 700"DRAINAGE MAT / � � FT. � �__�.. SLOPE 1/4"I FT. � � (E)FURRING (E)T8G WOOD DECKING NOTE: WATERPROOFING TO CONSIST OF 90 MIL FIRST COAT FOLLOWED BY REINFORCING MESH,THEN SECOND COAT OF 125 MILS AND SECOND LAYER OF REINFORCING MESH.INSTALL PER MANUFACTURER'S INSTRUCTIONS ❑� 2"CONCRETE TOPPING SLAB "HYDRODRAIN 700"DRAINAGE MAT HYDRONIC TUBING 6-INCH WWF SLOPE STONE Ya" �PER FT.TO DRAIN � Yz"PLYWOOD DECK ON TAPERED 2x SLEEPEFtS HYDRONIC TUBING 6x6WWF "HYDORTECH"FLUID APPLIED WATERPROI)F MEMBRANE AND CAF'SHEET SELF-LEVELING URETHANE SEALANT Z"ISOLATION JOINT FILLET SEALANT AT PERIMETER JOINT (E)STRUCTURAL SYSTEM AND DECK � � 1 _ NOTE Z �/ � ) � � % 2 z � � � ��r_.. Q `'��`��t':��, � �� ` '•'"'' .. 6✓��pH:`,� � �i ���, ti,�. .� � � � J N ^y) a.d � N Q .� � COPPER BASE FLASHINGIf�f�D INTO WOOD COLUMN-SOLDER MITERED CORNERS UNCURED NEOPRENE FIASHING SEALANT AT PERIMETER RANDOM PATTERN STONE TO MATCH EXISTING "HYDROTECH"FLUID-APPLIED WATERPROOFING MEMBRANE AND CAP SHEET , � (E)PLYWOOD DECK Yz"PLYWOOD DECK ON ORIGINAL DECKING (E)STRUCTURAL TIMBER COLUMN � � ( (E)FURRING �� (E)T&G WOOD DECKING WATERPROOFING TO CONSIST OF 90 MIL FIRST COAT FOLLOWED BY REINFORCING MESH,THEN SECOND COAT OF 125 MILS AND SECOND LAYER OF REINFORCING MESH.INSTALL PER MANUFACTURER'S INSTRUCTIONS Solutions Before Solutions After 468�Table Mowuin Orive,Uni11A Goldrn,N BOiN Ph(34i)4]5-�ZR F..:p2o�aa5osso Ht �M m m n.wma�a..�.ma o.a. �m SBSA M..Thq mry rot w Aiqka�a. !.n rtproEUnd Mqou1 qe epesE wXln oi msn e�.wor4��.ma nwxq.�.rt..x e. i me o�w�w�.a. � � � 0 < 0 �m �m �-] �-, � � H � W � �i � � Q `� Z � Q z w 0038 � � O Q � � � W H � FQ E� � � 3 � � � z a o x � U DRAWING SCALE: y"=]'-0" ]OB NUVfBER: 314037.00 1 A2.02 TYP. PERIMETER BALCONY TRANSITION @ DOOR THRESHOLD 2 A2.02 TYP. PERIMETER BALCONY TRANSITION @ TIMBER COLUMN DETA�� SCALE: N.T.S. A�.O� SCALE: 3"=1'-0" � � � a � � � TWO STAGE DECK DRAIN 2"CONCRETE TOPPING SLAB "HYDRODRAIN 700" DRAINAGE MAT HYDRONIC TUBING 6-INCH WWF SLOPE STONE%" PER FT.TO DRAIN �l UNCURED NEOPRENE FLASHING-TO 9"OUT FROM DRAIN EDGE 9"TYP. NOTE: WATERPROOFING TO CONSIST OF 90 MIL FIRST COAT FOLLOWED BY REINFORCING MESH,THEN SECOND COAT OF 125 MILS AND SECOND LAYER OF REINFORCING MESH.INSTALL PER MANUFACTURER'S INSTRUCTIONS A2,03 I TYP. PERIMETER BALCONY TRANSITION DRAIN SCALE 3"=1'-0" SEALANT AT PERIMETER RANDOM PATTERN STONE TO MATCH EXISTING "HYDROTECH"FLUID-APPLIED WATERPROOFING MEMBRANE AND CAP SHEET , (E)PLYWOOD DECK �z"PLYWOOD DECK ON ORIGINAL DECKING (E)DRAIN PIPING (E)FURRING (E)T&G WOOD DECKING z � N z � � : � `-�. (E)EXTERIOR WALL CONSTRUCTION SHINGLE-LAP NEW WRB UNDER EXISTING LAYERS NEW STUCCO SKIM COAT OVER JOINT CARRY WATERPROOFING UP WALL SURFACE 8"MIN FROM TOP OF SLAB (2)LAYER BUILDING PAPER LAPPED OVER FLASHING/SCREED BOTTOM STUCCO WEEP SCREED � ,;���_ Q tio ::...��,`? c�l ,���'':�.:;�'� O� ,n�•.�r.,ti. VI c�- ..q�;F�,- 3 ,-I � O J N �Y I L � N Q � � J (/') COPPER FLASHING WITH 4"VERTICAL LEG AND HEMMED EDGE UNCURED NEOPRENE FLASHING NON-SKINNING BUTYL SEALANT RANDOM PATTERN STONE TO MATCH EXISTING "HYDRODRAIN 700"DRAINAGE MAT %"PLYWOOD DECK ON TAPERED 2x SLEEPERS SLOPE 1/4"/FT. , L "HYDORTECH"FLUID APPLIED (E)STRUCTURALSYSTEM WATERPROOFMEMBRANE AN DECK SELF-LEVELING URETHANE SEALANT %"ISOLATION JOINT Z l/ i � FILLET SEALANT AT PERIMETER JOINT �Q�� NOTE: WATERPRObF1�0 CONSIST OF 90 MIL FIRST COAT FOLLOWED BY REINFORCING MESH,THEN SECOND COAT OF 125 MILS AND SECOND LAYER OF REINFORCING MESH.INSTALL PER MANUFACTURER'S INSTRUCTIONS 2 � A2.03 � TYP. PERIMETER BALCONY TRANSITION @ STUCCO WALL SCALE: 3"=1'-0" Solutions Before Solutions After E6P0 Table Mowuin Ihive,[lnit iTl co�da,,msoam �,3���,m e,::��so�3asmso ��P a�m InMrvme�l oi wNn mE va Me �ooms��,�.my m,r.a w mq�wa. �o�m��iwMNi.m.a�,m,e.1ma xnpYnwu.x G I m0 prweatM. � � � 0 < 0 �m �m 0 � � � H � C7Q �' � Q � z w � 030° � �-7 ,� `" � � �, � � Q � � h � � Q �7� � � � z � O � � x � u DRAWING SCALE: y"=7'-0,. )OB NU�ABER: 374037.W DETAILS A2.03 � � � � a � a � �a�iiP�G RE; S7f�U�i� F ��.IRRI�+,�C� ,��7!?€PC 1 G �- L A2.04 � RAILINGATTACHMENT - ORIGINAL DETAIL l�a�'....__ i��'.. 3�6" � �TT�AC�i 6i1 ivE���L i-'G �`trtU�Ji t���UVk �tN%��,}���'it%2 L.t�.. SGREWS iNTO 3X PRES. TRE:' w��Q �AS�, c�i�c�-�� �r� 1 X ��` �i..,.i��� r .. ��..� iiQf�`�.{.,{�r`tC:� �i�: 5 f= :or�rrv� i!b... RE: ` ��,�; y�� wat�� s�r�� s, IE"E PL. RE: c, PPEft �'��`�' "� � _ _�,;�,.. ?�t�t Tf) �TF74_4{`T"l!� � � � _' 1 �� / " � Solutions Before Solutions After 96BO Tablc Nowuin Ihive,L`ni�1�11 coiae,,m ewm Ph:(303)425-JDL Far(J20�345025p �r t�a.a�.w�i or...<.ma�a. r d�sA Mc.lney me�not ee mqim�N. a.a�moaaa.iuw�me.,w�e.�mm ,a mu�.crora��.me nrm9.,�«n..x e. 7 C � � < 0 �m � � � � c. � OH � � Q � za Q � zw �¢ � 03 °oA � � Qwz E--� � Q C7 E� � � 3 � � � � �- ° � z F' o ,..W.] a � � x � u DRAN7NG SCALE: y"=1-0„ JOB NUViBER: 314037.00 ORIGINAL DETAIL A2.04 � �o O � a d m x �