Loading...
HomeMy WebLinkAboutB15-0387 . . /�,� � 02-03-2016 Inspection Request Re ortin � Page 11 4:03�m __ �1�, CO - Citv O�__ - Requested Inspect Date: Thursday February 04,2016 Site Address: 133 WILL�W PL VAIL Riva Ridge Chalets Unit 16 A/P/D Information Activity: 615-0387 Type: COMBO Sub Type: AMF Status: tSSUED Const Type: Occupancy: Use: R-2 Insp Area: Owner: BAUM,SHARLENE Applicant: RAINVILLE CONSTRUCTION INC Phone: 970-376-5009 Contractor: RAINVILLE CONSTRUCTION INC Phone: 970-376-5009 Description: Redo kitchen cabinets,add powder room add small wash/drywer,paiting,hardwood flooring,carpets. Notice: Paper submittal-scanned to LF, routed to G1 -SBELLM Requested Insaection(s) Item: 90 BLDG-Final Requested Time: 10:00 AM Requestor: RAINVILLE CONSTRUCTION INC Phone: 970-376-5009 Comments: 376-5009 Assigned To: Entered By: JMONDRAGON K Action: Time Exp: Item: 190 ELEC-Final Requested Time: 09:30 AM Requestor: RAINVILLE CONSTRUCTION INC Phone: 970-376-5009 Comments: 376-5009 Assigned To: SGREM Entered By: JMONDRAGON K Action: Time Exp: Item: 29 PLMB-Final Requested Time: 08:30 AM Requestor: RAINVILLE CONSTRUCTION INC Phone: 970-376-5009 Comments: 376-5009 Assigned To: SG Entered By: JMONDRAGON K Action: Time Exp: Item: 390 MECH-Final Requested Time: 09:00 AM Requestor: RAINVILLE CONSTRUCTION INC Phone: 970-376-5009 Comments: 376-5009 Assigned To: SG Entered By: JMONDRAGON K Action: Time Exp: 'G ���� Inspection Historv Item: 120 ELEC-Rough **Approved" 11/03/15 Inspector: sgremmer Action: AP APPROVED Comment: Item: 200 MECH-Rough 11/03/15 Inspector: sgremmer Action: DN DENIED Comment: fire damper for bath exhaust fans Item: 220 PLMB-Rough/D.W.V. Approved'* 11/03/15 Inspector: sgremmer Action: AP APPROVED Comment: Item: 230 PLMB-Rough/Water "'Approved" 11/03/15 Inspector: sgremmer Action: AP APPROVED Comment: Item: 240 PLMB-Gas Piping Item: 30 BLDG-Framing Item: 50 BLDG-Insulation Item: 60 BLDG-Sheetrock Nail '*Approved*' 11/13/15 Inspector: martin Action: AP APPROVED Comment: Item: 70 BLDG-Misc. Item: 290 PLMB-Final ftem: 390 MECH-Final item: 190 ELEC-Final Item: 90 BLDG-Final REPT131 Run Id: 15038 NOTE: TH/S PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ,. �aw�o�v�tt.'. Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B15-0387 Project #: PRJ15-0571 Job Address: 133 WILLOW PL VAIL Applied.....: 10/02/2015 Location......: Riva Ridge Chalets Unit 16 Issued. . . : 10/2812015 Parcel No....: 210108214003 OWNER BAUM, SHARLENE 10/02/2015 75 CHERRY ST DENVER, CO 80220-5635 APPLICANT RAINVILLE CONSTRUCTION INC 10/02/2015 Phone: 970-376-5009 TODD RAINVILLE PO BOX 118 i RED CLIFF CO 81649 License: C000003894 CONTRACTOR RAINVILLE CONSTRUCTION INC 10/02/2015 Phone: 970-376-5009 TODD RAINVILLE PO BOX 118 � RED CLIFF CO 81649 License: C000003894 Description: Redo kitchen cabinets, add powder room add small wash/drywer, paiting, hardwood flooring, carpets. Occupancy: R-2 Type Construction: IIIB Valuation: $100,000.00 .........................................«.,___............_,.......,...,,..,.,... FEE SUMMARY ..........,.,,....,..,.........,.,.........,...,.,.�...........,,....,....,...,., Building Permit-----------> $993.75 Bldg Plan Check----------> $645.94 Use Tax Fee-----------------------> $1,800.00 Electrical Permit---------> $57.50 Elec Plan Check-----------> $37.38 Restuarant Plan Review--------> $0.00 Mechanical Permit------> $0.00 Mech Plan Check---------> $0.00 Additional Fees--------------------> $0.00 Plumbing Permit--------> $180.00 Plmb Plan Check---------> $45.00 Recreation Fee--------------------> $0.00 Investigation-----------------------> $0.00 Will Call------------------------------> $15.00 � TOTAL PERMIT FEES--------------> $3,774.57 Payments-------------------------------> $3,774.57 BALANCE DUE------------------------> $0.00 ....................................................«.....,,,,...,.,,...........,,............>....,.............,...............,.......«......,.........,........................... DECLARATIONS I agree to comply with the information and plot plan,to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM -4:00 PM. � combination permit_012811 � � � T��N�F�A� j �/�k x��.F k k w w i t w'R'k w k w'I w#f k}#��f R+�f e Ye 4 Y k w f e e f e'h k t k w 4}t(f r f!�Y f f�f fi w�f r f Y e fr+t R+1r x�fr f e f R f k k f f�#f w Y Yr R+w rt#wYr x f*R k I�x#k*f f��4 f 1'f k f�YrY`Y`#'Yr f Yr R f k f w f R f���f k w f 4Y`+�f Yr k f f w�R w#f/�*�*R f r+Y�k'R N f t t t/f 1r R a�f k*k 4• CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF � Permit#: 615-0387 Address: 133 WILLOW PL VAIL Owner: BAUM, SHARLENE Location: Riva Ridge Chalets Unit 16 •a k 4�+w�,!++w rt it k k w k M f/w#k*f f e�f�4 x f�R f f 4 Ye#r Ye f f e+�x�R x f x x t*4 f�+�i 4 k f Y`N w X YrYr X Yr M M 4 tr f f t�*k**f k*i t f f fi fr#'!+!�1 r t'R 41(i f�#f k A f�R f�R 1��e rt f f YrYI e e t�K f f r R t'f 4 f+t 4��R fiYr f YrYr�Yr��f#��*f f f�R���tYr A�ti t r f*f f f k�x#'�w+f 4*f combination permit_012811 � i � ������ � ..****..**********.****.,,****.«**��..**.*.«.**..**.*..***********„�*****.«.*«**********.****:**.**..*�***�.******.«.,,**,.*««***.<***�.*****.*..««.**** REQUIRED INSPECTIONS AND STATUSES ! Permit#: B15-0387 Address: 133 WILLOW PL VAIL Owner: BAUM, SHARLENE Location: Riva Ridge Chalets Unit 16 ...,.*.*.**,.��*�*.,..*.*****.�*.*�*.*.*.***.*«**„«***.,«*„**«*********,*****.**.****«*�*.�*.**,..***�*..****�,.���**�.*�**.�*«****„*�*«.,,*.**..*...*..... Item: 00120 ELEC-Rough Item: 00200 MECH-Rough Item: 00220 PLMB-Rough/D.W.V. Item: 00230 PLMB-Rough/Water Item: 00240 PLMB-Gas Piping Item: 00030 BLDG-Framing Item: 00050 BLDG-Insulation Item: 00060 BLDG-Sheetrock Nail Item: 00070 BLDG-Misc. Item: 00290 PLMB-Final Item: 00390 MECH-Final Item: 00190 ELEC-Final Item: 00090 BLDG-Final combination permit_012811 i �u"'•� Department of Community Development 75 South Frontage Road ���� ��.����., . —' Vail, CO 81657 7� Te1: 970.479.2128 ��j� �-�� `� www.vailgov.com ,/ Development Review Coordinator TRANSMITTAL FORM Use this form when submitting additional information for planning applications or building permits. This form is also used for requesting a revision to building permits. A two hour minimum buiiding review fee of$110 wili be charged upon reissuance of the permit. , , ;ApplicationlPermit#(s) information applies 'to: Attention: Revisions �Response to Correction Letter �� '' ��� ��attached copy of correction letter �� �Deferred Submiftal , (�Oiher ......................................................................................................................................................................................................................................................................................................: Project Street Address: ; (Number) (Street) (Suite#) I..._............................................................................................................................................................................... € Building/Complex Name: Description of TransmittaU List of Changes, Items Attached: ........................................................................................:: ;:Applicant Information j!(architect,contractor,owner/owner's rep) �Contact Name: �`� �i cti"����p `Address: Zt'I�v �O�,i't.�M.e�.%'�- ��- ;City J\P[� l:�� �k State: t,V_ Zip: � `i ;ContBCt Name: �,pr 1 N ����'� ��S`� � Q-d�-�C: <(use additional sheet if necessary) _ .,:.,,. - �t�to� 3`1e-.��cc�i . , :. Contact Phone: � Building Permits. � j���+` � �i � �r,1 <Revised ADDITIONAL Va[uations (Labor& Materials) 'Contact E-Maii: �e� C.1 `� h €(DO NOT include original valuation) r. I hereby acknowledge that I have read this application,filled out `Building: $ ; in full the information required,completed an accurate plot plan, !. and state that all the information as required is correct. I agree to ;Plumbing: $ ' comply with the information and plot plan, to comply with alI Town > ordinances and state iaws, and to build this structure according ;Electrical: $ ' to the town's zoning and subdivision codes, design review ap- ;; proved, International Building and Residential Codes and other ; Mechanical: $ ordina es of t wn a plicable thereto. �X - (�� � Total: �� ; �:OwnedOwner's Representative Signature{Required) _................._.................._................_......... ........_.............................._.._.__.... .......................................; ................................................................................................................................................................................................: Date Received: For Office Lise Onh•: Fee Paid; Received From: Cash Check# CC; Visa/MC Last 4 CC# exp.date: Authorization# � �? � ? . � � C � ry- � N � (D CD � � � � 3 � '��'►�! � �j � fp Vl � �" n' 11± � S/� J Q. � Q" � �1 � N � N �' �" N N �� b(p' !/�U� -,-��- w V! `�� P'��+ �• � � �� .� �� �-h � � � � O � �� � � c� � � � �. t�, n. . -, � � � � � � �. tD � � � � � � � �. � rn �� n:� w � 0 � _.._.._.._�.._._........_ �4 ...._....___.__..w__...�_.. { � 2�° ..,�,r 42�� __ 27�� � 116" r� ._ 21 7/16" 209116" 1/ " 99". _�3�. 27'1/1G' w _t;�, �t � W2136-L W4236 .NA � � � Nw � B�6L42-L' 621-D3 3�FOL s< � � m .., C N �,Nj � � i N � ..A J � J � � � � b . � _ . .... � _. � � �' � � � � � � i � {� ' ; C� . �_ : :- � � � ..a�..._.._a.. �N ' 'y ; : # �� 1� r E LQ � � "\ i '�.l 1 �� 1 � t 1 i ! o � . � N � p. AIf dimensfons and size designatlonr must be verified on the stte to fit job Client accepts these drawings as is, can use them on its ow�risk. DesEgn:Baum ' �, �, l T� Des3gn drawings are provided Designed:07.08.1: � for the fair use by the client or Printed:07.08.15 his agent in completing the project as listed within this contract Drawing#:2 Dispiay settings 1/2"=1' All dimensions and size designation; °�,, must ba verifled on the site to fit job - C)ient accepts these drawings as is� ' can use tham on its own risk. rM Design drawings are provided Designed:07.08.1; � for tha fair use by the clfent or Printed:07.08.15 his agent in compfeting the project as listed within this contract Design:Baum Drawing#:2 Display settings 1/2"=1' All dimensions and slze designationf must be varified on the site to fit job Client accepts these drawings as is� can use them on its own risk. TM Design drawings are provided Designed:07.08.1: €or the fair use by the client or Printed:07.08.15 his agent in compieting the project as Iisted within this cantraat Design:Baum Orawing#:2 Display settings 9/2"=1' � `Ct��l�''�L �hm�1�--� Ail dimensions and size designa8ons must be varifiad nn the site to fitjob c Clienk sccepts these drawings as is a can use them on its own risk. Design:Baum T►�; Design drawings era pravfdad - for tha fair use by the clie�t or his agent in completing the project as listed within ihis contra�t Drawing#:2 .--��� �� � Designed:07.08.1; Printed:07.08.15 Display settings 1 1/16"=1' J t Department of Community Development 75 South Frontage Road TOWN OF VAIL' van, co $�ss� Tel: 970-479-2139 www.vailgov.com BUILDING PERMIT APPLICATION (Separate applications are required for alarm &sprinkler) ' Project Street Address: W� Project#: ��'(j •(�'�j' 7� ��'�33 �a�C. �..lD �� ! Number DRB#: ( ) (Street) (Suite#) p ;� Building Permit#: p��' ��1 i Building/Complex Name: 11 ��/� COIJJ�' S N��T(� �Contractor Information Lot#: (I1 Block#� Subdivision:_ _��/( Business Name: �A I N U l I,L,� C(��S 1- �(N ------ ---------- Business Address: �O ��X ��Qj Work Class: New( ) Addition( ) Alteration (� n (� : :, _:_ _ ;City_ P.fl l--���+-- State: �. Zip: l�a�l Type of Building: --^ ;� Single-Family( ) Duplex( ) Multi-Family(r/) ' ,Contact Name: ��r�c1 11 I4 L r�v���� � i Commercial ( ) Other( ) Contact Phone:__��.0� 3nC� 'SbU�' , ,. _ _ t � �> Work Type: Interior(�Exterior( ) Both ( ) Contact E-Maif: `�C���'��f � `[u4�v0• Gc?M _ _. _ _ _-- --, --__ _. :.. .--: .,__.:._: __. .,:,,� _ ' Valuation of ' I hereby acknowledge that I have read this application,filled out V�/ork Included Plans Included Work I in full the information required,completed an accurate plot plan, and state that all the information as required is correct. I agree to "Electrical ( Yes ONo OYes ONo t(�'Q� comply with the information and plot plan,to comply with all Town '' ordinances and state laws, and to build this structure according to �Mechanical ( )Yes ( )No ( )Yes ( )No the town's zoning and subdivision codes, design review ap- / `�t Z dOO. c° ; ' proved, International Building and Residential Codes and other �Plumbing (�jJYes ONo OYes ONo , ordinances of the Town applicable thereto. I #� ,Building ( )Yes (✓�No ( )Yes ( )No � (�_ _........ _.__ . .__.. _. ,,...._... .... . . ......... __....,_. X �,. '� !Value of all work being performed: $ IU��C�7. 1� I(value based on IBC SecUon 109.3&IRC Section 108.3� 'OwneNOwner's Representative Signature(Required) ��� � �Electrical Square Footage A � +Applicant Information j Detailed Scope and Location of Work: Applicant Name: �� Qp i,�/v�1 Il ', re� k�� c��� c���� i Applicant Phone: �7O � 3�(� • Svo� ; �� ��d� ��» Applicant E-Mail: (��G�.�F �tr e `1�F-�. rD{Y1 ; �� S M a l I �,.,��, �dr�e f Project Information I �/�t IJ��/C , ''IJ�-(dc.�1 dp� !'��('. . �Q(,J C�jD�s 'Owner Name: Sh���«� 13�u�• � ' Parcel#: c�I�I ���d• 1�{ �>c� 3 (For Parcel#,contact Eagle County Assessors Office at(970-328-8640 or visit www.eaglecounty.us/patie) � ' " ` "` (use additional sheet if necessary) For Office Use Only: �1 Fee Paid: �02�-3O� Received From: Date Received: Cash Check# CC: Visa/MC Last 4 CC# exp date: Auth # 2014-0901 � .r SPAC6K TIMBI[AND B4EVINPi ENOIN6ERlNG INC September 29t'', 2015 Todd Rainville TG Renovations RE: MEP Engineering Review of Interior Remodel Riva Unit 210 Vail, CO Mr. Rainville, This letter is provided for your use in acquiring mechanical permit from the Authority Having Jurisdiction for mechanical, electrical and plumbing work necessary for the proposed remodel at the aforementioned location. The project consists of interior finishes remodel with added powder room, washer/dryer closet, and bar/sink niche. Below is a summary of our findings and recommendations. Engineering review is based on the 2012 International Code family as adopted by the Town of Vail. Mechanical Scope. 1. General: A complete life safety systems and code review of the entire building has not been perFormed as part of this effort; however, it appears from site visit that the drywall ceiling within the unit may interpreted to serve as the lower membrane of fire resistance rated construction. As such, we recommend any ducts penetrating this assembly be protected accordingly. 2. Powder Room Exhaust: Provide new 120V/1 ph ceiting mounted exhaust fan with radiation damper grille capable of producing 50 CFM minimum exhaust rate. Provide back draft damper at new fan duct connection and connect new 4" diameter exhaust duct to existing minimum 4" diameter exhaust serving adjacent bathroom. Verify existing bath exhaust fan is fitted with backdraft damper at fan. Add backdraft damper if none found. 3. Dryer Exhaust: New clothes dryer shall be ducted to convey moisture to outside the building unless selected unit is a listed and labeled condensing (ductless) clothes dryer. Dryer exhaust duct cannot penetrate ceiling membrane. Exhaust duct, if required by dryer type, shall be installed in either of the following scenarios: a. Completely belaw ceiling membrane in new saffit. b. Above ceiling plane in joist bay, but with fire resistance rated construction adjusted to create pocket to route exhaust duct. Though this solution may be aesthetically preferred, we deem it difficult and question feasibility. 4. Dryer Closet Makeup Air: Provide louvered door in closet with minimum 100 square inches free area. Riva Unit 210,Vail Colorado September 29'h,2015 MEP Engineering Review for Interior Remodel page 1 of 3 r" MEP Engineering Review: Riva Unff 210 Remodel, Vatl Colorado Electrical Scope. 1. General: The existing service is 100A, 240/120V, single-phase with dedicated utility meter. Because demand meter information was not available, a full NEC load calculation (based on optional feeder and service load calculation in NEC 220.82) was performed for the unit to verify adequate capacity for the existing load and the added loads of a wine cooler, stacked combination washer& dryer, and a small bathroom exhaust fan. Though exact data sheets were not available at the time of load calculation, we have made conservative assumptions based on generally known load sizes for each of the added load types and we have also included a future load adjustment equal to 10% of the entire units load. With this adjustment inc{uded, the total calcufated load for the unit is 80A. 2. Load Assumptions: a. Washer/Dryer—30A, 240V branch circuit with an assumed load of 5760VA. b. Wine Cooler—20A, 120V branch circuit with assumed load of 500VA. c. Exhaust Fan —Assumed fractional horsepower fan with a load of 100VA. 3. Provide GFCI receptacles in new powder room and in bar niche. Plumbing Scope. 1. General: a. Provide new domestic water, waste and vent connections to new plumbing fixtures in accordance with code. b. Waste and vent piping shall be asphaltum coated service weight cast iron soil �ip� ��d `r�b-t�ub' �ubber jbinfs wifk► sf�inle�� steel �I�m��. c. Domestic water shall be Type L hard drawn copper tube with wrought copper fittings and lead free solder joints. d. Water piping insulation: Molded fiberglass with fire resistant white all service jacket (ASJ) with preformed white PVC jacket at elbows and fittings. i. New cold water piping NPS 3/" and smaller shall be insulated '/Z" thick. ii. New hot water piping NPS 3/" and smaller shall be insulated 1" thick. e. New hot water fixtures connected to existing system shall not be further than 20 feet piping distance from recirculated hot water main. f. Piping in garage ceiling plenum: New water piping not permitted in garage ceiling plenum. Freeze protect waste & vent piping in garage ceiling plenum equivalent to existing. 2. New water closet: Flush valve type not permitted. Flush tank required. Connect to 4" minimum waste piping and provide 2" minimum vent. Provide NPS '/Z" branch cold water from nearest NPS 3/" minimum existing cold water service. Provide wall stop and water hammer arrestor listed for concealment or 12" air chamber in wall upstream of wall stop. 3. New handsink and bar sink: Provide 1'/2" minimum waste piping and 1'/4" minimum vent. Provide NPS '/Z" branch hot and cold water with wall stop for each. Extend hot and cold service from nearest existing NPS 3/" minimum hot and cold water piping. 4. New washer: Provide washer box with NPS '/2" hot and cold water connections with integral stop and hammer arrestor for each. Washer box shall include 2" minimum 5 � September 29fh,2015 page 2 of 3 � � MEP Engineering Review: Riva Unff 210 Remodel,Vall Colorado drain connection with 1'/2" minimum vent. Washer box waste standpipe shall be individually trapped, discharge to 3" minimum existing piping, and be 18" minimum high, but not higher than 42". Provide wall cleanout access above washer box fixture trap wye. Please let us know if you have any questions. Sin re , o�PpO LI�F� ; V�� .�F y� '' 18 J k B vin PE B Engi ering 'O�� • .. ,;G\�<v �SS�ONA��� 2'�'`�°� � (S� �� � � September 29'h,2015 page 3 of 3