B15-0390
_ 4 � �� 10-28-2015 � Inspection Request Re ortin Lj Page 24 4:04 pm VaiL CO - Citv O� �'Si5^- D��' I Requested Inspect Date: Thursday,October 29,2015 Site Address: 4093 SPRUCE WAY VAIL Vail East Lodging Unit 35 A/P/D Information Activity: 615-0390 Type: COMBO Sub Type: AMF Status: ISSUED Const Type: Occupan—cy: Use: R-2 Insp Area: Owner: MCDONNELL,JANET&SGOTT Phone: 720-431-6920 Applicant: COLORADO COMFORT PRODUCTS, INC Phone: 303-777-3234 Contractor: COLORADO COMFORT PRODUCTS, INC Phone: 303-777-3234 Description: Family Room Fireplace Conversion-Wood to Gas Notice: Paper submittal;scanned to LF, routed to F1 -SBELLM Requested Inspection(s) Item: 90 BLDG-Final Requested Time: 08:00 AM Requestor: COLORADO COMFORT PRODUCTS, INC Phone: 303-777-3234 -or- dave hall Comments: 303-88 58 Assigned To: Entered By: JMONDRAGON K Action: Time Exp: __ Item: 190 ELEC-Final Requested Time: 04:00 PM Requestor: COLORADO COMFORT PRODUCTS, INC Phone: 303-777-3234 -or- dave hall Comments: 303-886-8 Assigned To: J N Entered By: JMONDRAGON K Action: Time Exp: Item: 290 PLMB-Final Requested Time: 04:30 PM Requestor: COLORADO COMFORT PRODUCTS, INC Phone: 303-777-3234 -or- dave hall Comments: 303-886- 8 Assigned To: JMO ON Entered By: JMONDRAGON K Action: Time Exp: Item: 390 MECH-Final Requested Time: 03:30 PM Requestor: COLORADO COMFORT PRODUCTS, INC Phone: 303-777-3234 -or- dave hall Comments: 303-886-8 Assigned To: JMO Entered By: JMONDRAGON K Action: Time Exp: / � Inspection Historv Q �� �� ,� / Item: 120 ELEC-Rough " "Approved" 10/28/15 Inspector: sgremmer Action: AP APPROVED Comment: Item: 200 MECH-Rough "Approved" 10/28/15 Inspector: sgremmer Action: AP APPROVED Comment: Item: 240 PLMB-Gas Piping '*Approved" 10/28/15 Inspector: sgremmer Action: AP APPROVED Comment: Item: 190 ELEC-Final Item: 290 PLMB-Final Item: 390 MECH-Final Item: 90 BLDG-Final REPT131 Run Id: 14936 NOTE: TH/S PERM/T MUST BE POSTED ON JOBSITE AT ALL T/MES .• �1WNQF Y�tL`. Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B15-0390 Project #: PRJ15-0574 Job Address: 4093 SPRUCE WAY VAIL Applied.....: 10/05/2015 Location......: Vail East Lodging Unit 35 Issued. . . : 10/14/2015 Parcel No....: 210112204006 OWNER MCDONNELL, JANET& SCOTT 10/05/2015 Phone: 720-431-6920 16245 CADLAND CT PARKER, CO 80134 APPLICANT COLORADO COMFORT PRODUCTS, I 10/05/2015 Phone: 303-777-3234 255 WYANDOT STREET DENVER CO 80223 License: C000003239 CONTRACTOR COLORADO COMFORT PRODUCTS, I 10/05/2015 Phone: 303-777-3234 255 WYANDOT STREET DENVER CO 80223 License: C000003239 Description: Family Room Fireplace Conversion -Wood to Gas Occupancy: R-2 Type Construction: VB Valuation: $1,345.00 ......................»............«.,.._.._,...,..,.,,,.,,.,........._,,,,,....... FEE SUMMARY =........,,_...._................,.........._.,................................ Building Permit-----------> $50.95 Bldg Plan Check----------> $33.12 Use Tax Fee-----------------------> Electrical Permit---------> $57.50 Elec Plan Check-----------> $0.00 Mechanical Permit------> $37.38 Restuarant Plan Review--------> $0.00 $20.00 Mech Plan Check---------> $5.00 Additional Fees--------------------> ($109.07) Plumbing Permit--------> $15.00 Plmb Plan Check---------> $3.75 Recreation Fee--------------------> $0.00 Investigation-----------------------> $0.00 Will Call------------------------------> $15.00 TOTAL PERMIT FEES--------------> $128.63 Payments-------------------------------> $128.63 BALANCE DUE------------------------> $0.00 ......................................................,._.......,...,._........,..,........,............,...,.._............_......,,....,,.........._._,....,......,.,....>,....,,,_... DECLARATIONS I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM -4:00 PM. combination permit 012811 � � • � 1 11�V� 1`t11L � ..................................................................................................................................................................................... CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit#: 615-0390 Address: 4093 SPRUCE WAY VAIL Owner: MCDONNELL, JANET& SCOTT Location: Vail East Lodging Unit 35 ..................................................................................................................................................................................... combination permit_012811 I ! � TOWN t}F VA�L ` *.,***.***.,***�***„****....,.*„*�**.*************,*„****„*********„**.*************,***„*************,****,**,*********,*******,**.***,*�*,****..**** REQUIRED INSPECTIONS AND STATUSES Permit#: B15-0390 Address: 4093 SPRUCE WAY VAIL Owner: MCDONNELL, JANET & SCOTT Location: Vail East Lodging Unit 35 *****.***„«„*««*.*,,,,*„««*��.,******.*****�,*...*****.******«««***,,,,***«*«�**,.**„**«****«********„**««***«*****��******,,,.**************«*�...***««**„*,. Item: 00120 ELEC-Rough Item: 00200 MECH-Rough Item: 00240 PLMB-Gas Piping Item: 00190 ELEC-Final Item: 00290 PLMB-Final Item: 00390 MECH-Final Item: 00090 BLDG-Final combination permit_012811 i _•----- 0� ��� �,�o n-, �� � � �� �.� �. � 't _ __��w'�,I �Lb�� � \ � � � O { , r � �� ���� p r ���� � �� S � � �-~- � � �d �, �� � �,�R��' , �� � � �L� ,��.��� : ��� Y� : 2� o � � � � _.,_�� � ; N � � f .......�.�nr.�����_.b_��.�..._._............ � �_ _-- _-- _ ___ ...T.�,.._ ��� � V��--- , q,� e��.:�p�". � �. �. ,�„��,.�`�� x��� V���� � .. . .. �_/� .., . //� � � � /�/ � V � �� � �.flJ���, /� ��r �� � � Department of Community Development 75 South Frontage Road � \ Vail,CO 81657 TOWN OF VAiI Tei: 970-479-z�zs � www.vailgov.com Development Review Coordinator BUILDING PERMIT APPLICATION (Separate applica6ons are required for alarm 8�sprinkler) Project Strr.et Address: �� �, Pro�e�t#: ��i5 �5`1� �/D 3 �PRuC.� `I �_ DRB#: (Number) (Street) (Suite#) Building/Complex Name: �A I L E��jT �,p'��t N(.7 Buiding Permit#:_���'�3�� Contractor Informatlon Lot#: `� &ock#� Subdivision:(7i��in 3ic� /� /� G F � Business Name: � l..-o�.O�Rbf� C.:c�mFo/27� _ . _ Business Address: ��SS I/1l`'//�}NX�v? ST. WO����� New�) Addidon �) Alteration(� City -�F(� ��.1�� State: � Zip: Type of Buildin : 223 Si I�Famil Du lex Multi-Fami �'.. �9 Y� P � Y� Contact Name: - • Commercial� Other�) Conta�t Phone: _ o - - Contact E-Mail: ork Type: Interior Exterior O Both O �,-,a�'� 1 C�� GflM _ I hereby adcnowledge at I have read this appliqtion,filled out Valuation of in full the information required,completed an aa:urate plot plan, Work Induded Plans tnduded Work and state that all the information as required is correct. I agree to � - - - '� comply with the information and plot plan,to comply with all Town E����I �Yes �No �Yes No �lUr7 � ordinances and state laws,and to build this structure according to ;Mechanical �Yes �No OYes �No ��� the town's zoning and subdivision codes, design review a� � a b�. ✓ proved,Intemational Building and Residential Codes and other ;,:plumbing �Yes ojNo QYes �No / ordinances of the Town applica le thereto. Building OYes �No OYes �No '-- x ���/��y'� __ _ _ ;Value of all work being perFormed: $ OwnedOwner's Representative Signature(Required) `;(va�ue�ed«,iac sec�on�os.3 a iRC�os.� � C ;Electrical Square Footage / �f J __ _.__ _. __ _ _.. ! __ _. _ Applicant Ir�formation � Deta�7ed Scope and Location of Work: a ApplicantName: � °"'N�"��- �O/l/Vi�T/�G �°� 1�u�QNIN(7 Applicant Phone: 70��"' 7 3 �- c(�/v�� �(Z.G1'L� "'�'O �'�J ��R��L�C.� �APP�icant E Mail: �GLY►'l�dnn e/�l� ca u-�hQ.o.� ��/�1� �.✓�'l l 1..�( 1��a Y✓� . Project InfoRnation �� �.y�� Owner Name• I � � oN���- Parc�l#: o�l�/ /0?02 �7 00�o (For Parcal*,eorMaet Eayls CouMy Asssssas 011ia at(970-32a-t6�10 or visit www.eaglecour�ty.udpatie) , (use additional sheet ff necessarY) For Office Use Only: � � � � � `a Fee Paid: Date Received: D Reaeived From: �1t�� Q 5 20�5 Cash Check# CC: Ysa/MC Last 4 CC# exp date: �• �� 7W1 Auth # TOWN OF �/�11 L ` � MENDOTA "SEABROOK" DIRECT VENT GAS FIREPLACE INSERT WITH HEARTHGLO COMBUSTION SYSTEM Model D-40 Dee Timber: Flat or Ba �� �. � t ► . � ,�.,�` � . . �_� \ % �; �.� \ � ` � I -=��. tl�.�;: �+ I '�"` � � � _ _-- I \■ �_I __ �D40 Flat shown with optional Andover poor and Overlay) INSTALLATION & OPERATING INSTRUCTIONS NATIONAL We recommend that our gas NO. DT-0806� FIREPLACE INSTITUTE hearth products be installed and serviced by profes- ""`"AN51""'°^" sionals who are certified in ` "'"^'°`k"""� = the U.S.by the National ° `�� N Fireplace Institute�(NFI)as �T�° ` �er,�ea �ERTIF�IED9 NFI Gas Specialists. � GasAppliance ° WARNING: THIS APPLIANCE TO BE USED ONLY AS AN INSERT IN AVERTISSEMENT:Cet appareil a etre employe seulment comme un inserer dans SOLID FUEL BURNING FIREPLACES. lecarburant solide brulant des cheminees. NOTE: THE NATURAL VENT(B-VENT� SYSTEM CANNOT BE USED TO VENT THIS INSERT MODEL! WARNING: This product must be installed by a licensed plumber or gas fitter when installed in the commonwealth of Massachusetts. Improper installation, adjustment,alteration,service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a quali6ed installer,service agency or the gas supplier. FOR 1'OUR SAFETY: DO NOT STORE OR USE GASOLINE OR OTHER POUR VOTRE Sewrite: Ne pas entreposer ni ufiliser d'essence ni d'autre vaperures ou liquides FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY inflammables dans le voisinage de cet appareil ou de tout autre appareiL OTHER APPLIANCE. FOR YOUR SAFETY:WHAT TO DO IF YOU SMELL GAS: POUR VOTRE Securite:Que faire si vous sentez une odeur de gaz: 1.OPEN WINDOWS. 1.Ne pas tenter d'allumer d'appareil 2.DON'T TOUCH ELECTRICAL SWITCHES. 2.Ne touchez a aucun interrupteur.Ne pas vous servir des tele phones se trouvant dans le bafi- ', 3.DO NOT USE ANY PHONE IN YOUR BUILDING ment ou vous vous trouvez. 4.EXTINGUISH ANY OPEN FLAME 3.Evacuez la piece,le batiment ou la zone. li 5.IMMED[ATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR'S PHONE. q,pPPelez immediatement votre fournisseur de gaz depuis un voisin.Suivez les instructions du 'I 6.FOLLOW THE GAS SUPPLIERS INSTRUCTIONS. fournisser. 7.IF GAS SUPPLIER IS UNAVAILABLE,CALL YOUR FIRE DEPARTMENT. 5. Si vous ne powez rejoindre le fournisseur de gas,appelez le service dos incendies. I WARNING: IMPROPER INSTALLATION,ADJUSTMENT,ALTERATION, AVERTISSEMENT:Une installation,un reglage,une modification,un entrefien ou une mainte- SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY nance inwrrects peuvent entrainer des dommages materiels,des lesions corporelles ou la perte de DAMAGE. REFER 1'O THIS MANUAL. FOR ASSISTANCE OR ADDIT[ONAL vies humaines. Consuter le manuel des usagers fourn avec ce generateur d'air chaud. INFORMATION,CONSULT A QUALIFIED[NSTALLER,SERVICE AGENCY, OR THE GAS SUPPLIER. MISE EN GARDE: Installafion,reglage,modification,entretien ou depannage non appropries pourront causer des blessures ou des dommages materiels. Referez-vous au manuel du proprietaire fourni avac cet appariel. Pour assistance ou renseignements complementaires,veuillez consulter un installateur experimente,une agence de depannage/entrei6en ou cotre compagnie gaziere. Pour utilisafion avec les portes en verre cerfifiee 1'appareil suelement Ne pas operer avec le verriere enleveq craquelure,brise. ' �I CONGRATULATIONS! �, You are the owner of a world-class heat producing gas fireplace insert. This elegant, highly efficient insert will be a constant source of comfort and fascination. It will be the focal point of beauty and interest in your home. The Mendota Gas Fireplace Insert is a true heating appliance incorporating the traditional aesthetics of � fireplace fire viewing with the controllability and fuel efficiency of a home gas furnace. Of particular interest is the low fuel consumption and brilliant fire viewing afforded by the patented realistic Hearth- '� Glo wood fire-like combustion system. �, I Carefully read the following instructions prior to actual installation. Proper Mendota Gas Fireplace In- I, sert installation and operation will give you years of safe trouble free comfort and enjoyment. ', If you have any questions regarding installation or operation of your Mendota Fireplace Insert please I contact your local dealer. ...CAUTION... FOR YOUR SAFETY do not install or operate your Mendota Gas Fireplace Insert without first reading and understanding ' this manual. Any installation or operational deviation from the following voids the Mendota Gas Fireplace Insert Warranty j and may prove hazardous: �I Due to high temperatures,the Fireplace in which the Insert is to be installed should be located out of traffic and away from ' furniture and draperies. Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition.Young children should be carefully supervised when they are in the same room as the Mendota Gas Fireplace Insert. Clothing or other flammable material should not be placed on or near the Insert. , Mendota lnserts are designed for installation only in vented non-combustible fireplaces. Any fireplace in which an Insert is ' to be installed MiJST be vented to the outside in accordance with the latest addition of Natural Fuel Gas Code. Do not con- ' nect this appliance to a chimney flue serving a separate solid fuel-burning appliance. Any gill,panel or glass removed for servicing the Insert MUST be replaced prior to operating the Insert. The Mendota Gas Insert is a powerful,efficient heating unit. It has been designed as a majar source of supplemental heat.It should not take the place of,or be used as,a whole house heating system. Installation and repair should be done by a qualified service person. The Insert should be inspected before use and at least annually by a professional Mendota approved service person. More frequent cleaning may be required due to excessive lint ' from carpeting,bedding material,etc. It is imperative that control compartments,burners and air passageways be kept clean. DO NOT use this insert if any part has been under water or exposed to moisture corrosion. Immediately call a qualified ser- vice technician to inspect the Fireplace Insert and replace any part of the control system and any gas control that has been under water. DO NOT use this insert if burner does not light immediatelv. If burner does not light promptly,turn off unit i and call your Mendota dealer. It is Johnson Gas Appliance Company's policy that no responsibility is assumed by the Company or by any of its employees or representatives for any damages caused by an inoperable,inadequate,or unsafe condition that is the result,either directly or indirectly,or any improper operation or installation procedures. INSTALLER: THESE INSTRUCTIONS ARE TO REMAIN WITH HOMEOWNER. I 2 MENDOTA D-40 GAS DIRECT VENT FIREPLACE INSERT SPECIFICATIONS & CLEARANCES 34 �24-�{ � O 16 1/4 13 1/4 � TOP VIEW 8 IN.MIN.CLEARANCE MANTEL � 12"MIN. FROM TOP TRIM OF GRILL B D-40 Surround Dimensions TO MANTEL � � A B Inches mm. Inches mm. No Trim 31 788 44 1118 33 838 48 1220 24 314 A 36 914 52 1321 With Black 31 1/16 792 44 1/8 1122 or Brass Trim 331/16 843 481/8 1224 �r 36-�� 361/16 920 521/8 1326 FRONT VIEW 8"MAX.MANTEL DEPTH(WIDTH) I 5/8� � I 13 114 � � 4-6 CO-LINEAR ADAPTER I � 24 5/8 22 3/4 19 16" MIN. NON-COMBUSTBLE � � HEARTH EXTENSION CO-LINEAR VENT ADAPTER MENDOTA D-40 GAS DIRECT VENT FIREPLACE INSERT 4 INSTALLATION INSTRUCTIONS CAUTION: Each installation must conform to all local,state and national codes.Refer to the national fuel gas code and local zoning and code authorities for details on installation requirements.The Mendota Inserts must be vented to the outside in accordance with the latest edition of the National Fuel Gas Code. In the absence of local codes,the installation must conform with National Fuel Gas Code ANSI Z223.1 (NFPA 54),or Canadian Code CANI-B149 or most current edition,also known as NFPA 54. Do not connect this InseR to a chimney flue serving a separate solid fue]or gas-burning appliance. 1. Remove glass doors, metal fire screens, etc. from existing fireplace. Be sure there is 12" minimum distance from top of upper grill to bottom of mantel; see Specifications [Pg.4 & 5], and a 16" mini- mum non-combustible hearth extension in front of the glass surface if a raised hearth is not supplied. (See pg. 14 for "Raised Hearth"). 2. Remove any additional framework or other obstructions in the existing fireplace opening and burn- ing area. Also remove any chimney cap from top of chimney so that vent liner can be installed freely. 3. Before Insert is installed, have gas supplier or contractor run gas line to the existing fireplace. Be sure �as plumbin� instructions [see P�. 15 & 16 are carefully followed. Gas supply may enter fire- place on either side or back of fireplace, whichever is most convenient and accessible. Electrical �, service (120 volt) should also be supplied [See electrical requirements on Pg. 3 and blower instruc- I tions on Pg. 29]. ! 4. The entire chimney should be swept to remove creosote, soot and any obstructions (bird nests, etc.). I 5. Open fireplace damper. If damper opening is large enough to accept 4" and 6" flue liners, perma- nently secure damper in "open" position. NOTE: Massachusetts requires that the flue damper must be removed or permanently welded in the "open"position. , I 6. If damper opening is too small for the 4" & 6" flue liners, it will be necessary to remove the damper I handle and the damper plate. Some damper plates are held in place by a pinned hinge that can be re- ! leased easily by tapping out the pin with a hammer and punch. Others may be held in place by a I screw or bolt, or pivots may be cast into the damper housing. The latter types may be harder to get out and may require sawing or breaking out. [NOTE: if flue size is 6" (127 mm) or less, or if severe 'i offsets occur, or a significant mortar slop is evident between the liners, try to snake liner down the !� chimney to the top of the damper housing before breaking out damper plate and housing.] ', �i CAUTION: If 4" & 6" flue liners cannot be installed in an extremely tight chimney DO NOT pro- �I ceed with installation. �� 7. If damper opening is narrower than 4-1/2" to 5" (114 mm to 127 mm) and if local code authorities , allow, loosen and remove mortar behind back side of damper housing in the center of the opening , enough to get the gripping teeth of a pipe wrench over the flange of the damper housing (for cast ', iron housings). Tighten the wrench snugly, and kick down on the wrench handle to break out a half 'I moon shaped piece of the damper housing, enough to easily fit the flex liner through it. If the open- 'I ing is wide enough,the break out is not necessary. �, 8. Install Insert only in chimney heights of 12' (minimum) to 35' (maximum) -- as measured in � step 9 below. 9. Measure the chimney height from the top of the chimney (or the existing flue liner) to a point 23" (584 mm) above the floor of the fireplace hearth. It may be necessary to drop a rope and measure the rope itself. Be sure to allow for all offsets in existing chimney. Cut the 4" diameter flex liner(s) to this measured length. 6 DURA–VENT CAP OR „Z—AMERI–VENT CAP III ll OR), 45-01 —001 53 irdiul 11610 FLASHING/CAP ADAPTER 4iiiiio I I 50-06-00073 s CLAMP 7 4" DIA, FLEX 35' [:[ —t-,5 El — 4" DIA. FLEX�==� 4" DIA. FLEX 6" DIA. FLEX i 50-06-00073 a ems, CLAMP _ 45-01 -00123 IV .11.1— D.V. ADAPTER _ , _ J 45-01 -0012 4 liii D.V. ADAPTER —+ WIll AA-11-378 CO-AXIAL VENT KIT AA-11-377 CO-LINEAR VENT KIT FIGURE 4 NOTE: THE INSERT IS DESIGNED,TESTED&LISTED FOR OPERATION ONLY WITH MENDOTA INSERT VENTING COMPONENTS AS LISTED IN FIGURES 3,3A,4&4A. 11. (See FIGURE 4A)The vent kits include a trimable flashing. Measure,trim and shape flashing to fit the existing flue liner. This flashing prevents water and small animals from entering area between the chimney liner and flue liner. Plan for 1"to 1-1/2"(25 mm to 38 mm)overlap on each side. Center the flashing and mark it about 3" (75 mm)larger in each dimension than the existing chimney. Trim the notch with snips and bend edges with hand seaming tool,metal break or pliers. -1---- ouri. iiiiii„,__CAP Iht 1 8 *a '.,.,...�,f,,,.:.l : :i�.�•1/ 11111111 ♦v......•..♦ FLASHING III.... , � 18 -1 FIGURE 4A: Chimney Flashing and cap 8 14. TYPICALLY FOR FACTORY BUILT ZC FIREPLACES,REFER TO PAGE 7. Use Mendota Co-Axial Vent Kit--#AA-11-00378 4" exhaust flex pipe extends full length of chimney from vent boot adapter to vent cap. 6" inlet flex pipe extends from vent boot adapter to existing chimney,above damper area(approx.4-5 ft.). Tightly secure flex vents with clamps provided. Seal vent cap/flashing to top of chimney with weatherproof sealer. Seal areas between 6"flex pipe and chimney,at damper area,with unfaced fiberglass insulation. 15. TYPICALLY FOR MASONRY FIREPLACES,REFER TO PAGE 7. Use Mendota Co-Linear Vent Kit--#AA-11-00377 4" exhaust flex pipe extends full length of chimney-from vent boot adapter to vent cap. 4" inlet flex pipe extends from vent boot adapter to existing chimney,above damper area(aprox.4-5 ft.). Tightly secure 4" flex pipes using clamps provided. Seal vent cap/flashing to top of chimney with weatherproof sealer. Seal areas between 4"flex pipes and existing chimney,at damper area, with unfaced fiberglass insulation. 16. You are now ready to install the Mendota Gas Insert. A. Lift Insert vertically from carton/pallet. illp DOOR TABS 0411== 0 ICI v.! - SPRING TABS ���_���d�'�.I�� SPRING BAR iimi FIGURE 6 : OPENING THE GLASS DOOR 17. Remove 5/16" nut and locking u-clamp from vent boot adapter(See FIG.7A,Pg. 12). 18. You are now ready to hook up the Insert to gas supply. Be sure gas plumbing instructions, [Pg. 15 & 16], and all state and local codes have been carefully followed. Be sure all items on Installation Check-Off List [Pg. 17]have been completed. NOTE: AGA APPROVED FLEX LINES ARE APPROVED FOR USE WITH MENDOTA INSERTS. 1 0 A. Place u-clamp over threaded rod. Thread clamping nut on threaded rod and tighten firmly. B. Reinstall exhaust baffle by placing rear edge on ledge, swinging front edge upward and reinstalling two (2) sheet metal screws. CAUTION: The exhaust baffle must be rein- stalled before operation. CO-LINEAR BENT ADAPTER BOOT FRONT I 'b „mut FIBERGLASS THREADS SEAL DOUGHNUT U-CLAMP J 5/1 6"NUT SIDE VIEW CO-LINEAR CO-AX VENT ADAPTER BOOT FRONT THREADED ROD FIBERGLASS AWN �SEAL DOUGHNUT U-CLAMP 72) 5/1 6" NUT SIDE VIEW CO-AXIAL FIGURES 7A 1 2 RAISED HEARTH SPECIFICATIONS INSERT LESS THAN 16" NON—CONBUSTIBLE PROTECTOR PROJECT d LOWER GRILL THIS LINE I 'NO PROTECTION f-- NEEDED IN SHADED RAISED HEARTH AREA FLOOR LEVEL 16° 2 X DIMENSION LUMBER OR CONCRETE BLOCK FIGURE 9 In most installations, a 16" non-combustible protector is required in front of the unit's glass door sur- face on the floor or raised hearth. This protection can be any non-combustible material such as 24- gauge sheet metal,tile,brick, concrete board, etc. Please note that the required 16" clearance starts at the front face of the glass door. If replacing a wood-burning insert with this gas insert,the exist- ing and approved hearth protection will provide adequate floor protection. If a raised hearth extends less than 16", refer to the diagram above and the following procedure to see if additional floor protection is required. Project a line(using string or a tape measure)from the top of the lower grill to the edge of the raised hearth, continuing on to the floor. If the point of intersection with the floor is beyond 16" from the Insert,then no further floor protection is required. If the intersection is less than 16" from the Insert then additional non-combustible floor protection is required to meet the minimum 16". For installations where the fireplace is raised 16" or more (from the top of the lower grill) above the floor or if the floor is non-combustible (stone, brick, etc.), a non-combustible protector is not re- quired. 1 4 GAS PRESSURE REQUIREMENTS A MAJOR CAUSE OF OPERATING PROBLEMS WITH GAS APPLIANCES CAN BE IMPROPER GAS PRESSURE! Such problems as changes in flame color or configuration,gas pilot or burner outages,intermittent operation, changes in heat output,excessive burner noise,etc.are nearly always the result of changes in gas pressure or im- proper gas pressure at the time of the installation. The most important item to check during the installation and the first thing to check when problems occur is gas pressure! Gas supplies normally enter a residence at 1/2 PSI(13" - 15" W.C.)(3. KPA). A regulator is then placed inside the residence,which drops this pressure to 7" W.C. (1.8 KPA)(Nat. Gas). This "inches to inches" regulator is of adequate capacity to service the gas appliances(such as dryer,furnace,etc.). If this regulator's capacity is not sufficient to add the Gas Fireplace, an additional "inches to inches"regulator must be installed for the Fireplace. EXCEPTION: Some codes allow 2-PSI(1.4KPA) supplies to enter the residence, in which case "pounds to inches"regulators are used. The following table provides information on correct gas pressure requirements. Be sure your gas supplier or plumber carefully follows this table. DESIRED MINIMUM MAXIMUM MANIFOLD AIR SHUTTER INLET INLET INLET OUTLET POSITION* PRESSURE PRESSURE PRESSURE PRESSURE NATURAL GAS 7.0"W.C. 5.0"W.C. 11"W.C. 3.5"W.C. 1/8- 1/4"OPEN (1.75 kPa) (1.12 kPa) (2.61 kPa) (0.87 kPa) (7 mm) L.P.GAS 11.0"W.C. 11"W.C. 13.0"W.C. 10.0"W.C. '/2"OPEN-MIN. (2.75 kPa) (2.75 kPa) (3.24 kPa) (2.5 kPa) (14 mm) TURN GAS VALVE KNOB TO"HIGH"POSITION. GAS PRESSURES MAY VARY PLUS OR MINUS 5%. 'NOTE: FOR HIGH ALTITUDE (ABOVE 5.000 FEET)SOME VARIATIONS IN AIR SHUTTER SETTINGS MAY BE REQUIRED. Manifold pressure must be taken at the MANIFOLD"tap and inlet pressure at the"SUPPLY"tap with the burner operating by a qualified installer(see Figure 10: Pressure Test Port). MANIFOLD PRESSURE TAP HI LO r INLET REGULATOR 71I PRESSURE TAP THERMOPILE •, se THERMOSTAT i 4 sP. 'f .M. y►''' THERMOPILE —*2 y ( tit I QFk '1071 �y� ON/OFF GAS THERMOSTAT—*3 La i . CONTROL KNOB PILOT GAS LINE—r "ti ! kluv ` PILOTADJ. SCREW Figure 10: Pressure Test Port GAS LEAK TEST REQUIREMENT: It is the responsibility of the installer/service person to assure that each and every gas connection and supply tubing that are a part of this fireplace are leak proof. The qualified/ certified individual connecting the gas supply line, performing pressure tests or performing any service to this fireplace is required to perform a THOROUGH LEAK TEST on ALL gas fittings that are a part of this appliance or the gas supply line connection using soap-water solution or a calibrated combustible gas detector. Failure to perform this leak test may lead to a house fire and/or an explosion. Mendota is not responsible for any damages due to an Installer's failure to conduct a leak test and verify that all connections and supply lines are leak proof. 1 6 LIGHTING INSTRUCTIONS IMPORTANT: Be sure all items on"LIGHTING CHECK OFF LIST"[Pg. 17]have been completed! CAUTION: If the pilot goes out,be sure to wait a minimum of five minutes before relighting-BE SURE TO ALWAYS REMOVE THE GLASS BEFORE RELIGHTING THE PILOT. 1. Remove glass door-ALWAYS LIGHT PILOT WITH GLASS REMOVED! 2. Make sure any gas supply shut-off cocks are open and Thermostat is MANIFOLD "OFF". PRESSURE TAP MI LO INLET 3. Push in Gas Cock Dial Slightly and turn clockwise to"OFF". NOTE: Dial THERMOPILE REGULATOR =SURE SSURE TAP cannot be turned from"PILOT"to"OFF"unless dial is pushed slightly.DO THERMOSTAT} NOT FORCE! THERMOPILE-►2 A• ON/OFF GAS THERMOSTAT-►3 - CONTROL 4. Wait five(5)minutes to allow gas which may have accumulated in main KNOB burner compartment to escape.If you smell gas,STOP. PILOT GAS LINE-+01», , 0 5. Turn Gas Cock Dial Counterclockwise to "PILOT" position. PILOTAO1 SCREW I— 6. Depress Gas Cock Dial and push in red Piezo igniter button. Once pilot ig- nites,continue depressing dial for about 1/2 minute. If pilot does not remain ig- FIGURE 11: Gas Valve nited,repeat operation allowing a longer period before releasing Gas Cock Dial. IMPORTANT: After pilot is lit,system millivolt readings and gas pressure should be taken by qualified installer. Pilot flame must register a minimum of 325 millivolts. 7. Push Rear Flame ON/OFF switch to"on". This switch is located behind lower grill on left side. See below. OO 0 ON SCREW OFF CD OW REAR BLOWER FLAME CONTROL MENDOTA BATTERY BY . � • 000 BATTERY (S6BMD PAN6L J \ Amenca s Premiere Fireplaces he 9 Volt Battery required for the Rear Flame ON/OFF function is mounted on the back-side of the Control Panel shown in the diagram above. To access this battery,remove the control panel mounting screws and flip this panel downward. Replace the battery with a high quality 9V Battery only. 8. After pilot is lit and before installing logs,turn Gas Dial to "ON" and"cycle"the burner on/off to make cer- tain it ignites promptly and that the flame runs smoothly around burner curve and promptly lights entire burner. 9. With pilot operating, install log set and coals(see PG.20). With logs/coals in place, "cycle"the burner again to make sure of prompt ignition of burner and that the flame runs smoothly around entire burner. NOTE: Logs will produce a strong,acrid odor on initial contact with flames. 10. Reinstall glass front by "hanging" slots on upper edge of door over tabs on upper edge of firebox opening. Then"swing in" lower edge of door. Carefully pull out the two(2) Spring Loaded Door Holding Bars located under the doorframe. Raise Bars and fit Bars firmly into Bar Holding Brackets on doorframe(see instructions PG. 10). 11. NOTE: Be sure doorframe is "centered" in firebox opening. To "center": Release Door Holding Bars,with door"hanging" in upper slots "slide" door frame(within the slots)to center of firebox. Replace Door Holding Bars. 12. Turn Gas Dial counterclockwise to "ON"then set Thermostat or push Remote Control to turn on burner. 1 8 DEEP TIMBER LOG SET INSTALLATION INSTRUCTIONS With door removed, carefully remove the shipping foam pack, containing the logs, from inside the firebox. 1. Cut the clear tapes and outer plastic wrap using a sharp utility knife or equivalent. Locate the 2 bags of coals and the log pieces.Identify each log piece,A-F and the Large Chunk coals and Small coals per the diagrams show on this page: 4 ,,,,- __ ...... , ..,. ,,, ...,,,,,-,. _ , ...... . . - ,, „t- ' ,4 M 1 .i._ • NI LARGE CHUNK COALS SMALL COALS ,," LOG A OG F ,., T., '. �. -.- ' - '7.: r ..:, i �, LOG - LOG B x l� 3 L -4, 40"16 I y - 7 r,. .f LOGD ' LOGE LOGC Disclaimer: All figures in the following sections are for representation purposes only. Your model may vary slightly from those pictured below! 2 0 4. Place right front log"C" behind front burner as shown. Front to Back; place this log so that its rear-most edge is 1/8" away from the center burner tube. Adjustments to this location can be made later during Log"G"installation. — •• '' -....,.•• -��, tom"- '. - k - is S as; >A a ,'A �' ' .� r l n t e, LOG C 1. 5. Place left front log "D" behind front burner and in front of Pilot Light, as shown. Butt Log "D" against Log"C". . -- .. f 1 ate. .i, - - - : dr^0 LOG D 1 - *To", _ 4 = - .........".1.---., "111.11".:-'. . _ 7. Place left front log "F" as shown in the diagram below. Identify Pin on Log "B" and Hole in Log "F". Place Log"F" so that the hole in log "F" falls over Pin in log"B", see diagram below. Front right cor- ner of Log"F" must rest on left-most Log Iron Bar as shown in the next diagram. HOLE PIN d LOG F ` 0 , ��-I"' -7"K - *- c ty■ ate- ai: J{ , •^, .os`Tc.1.,�yv, °L1. t .,:e..-... _ 4 J / y,tom,t i - r 1 l'?t 4 - • S � v- - tMr w w� ..i�;_ . !,))l j[ 4 ` . . „ : , � al /! � :-- 7; a. ti �_' I. j ;.. F .k cam: . . y±�,y•: •"1I w _ Ar r lip,r; .. 4 it . ...1 ' i J kill '. f- ...' ' • e t✓.rr t ' /'. f 6f f ? - ` •'"• -. LOG "F" LOCATION Make Certain that the front right corner of Log "F" sits on the left-most Log Iron Bar as Shown in the diagram, above. 2 4 1 w , • _,,.__ _ .......... - k .1x -J ft — � i'.y, a Imo % ■ Front corner of Log "G" must rest on right-most Lou Iron liar. This locates Lou "G" properly. y /� 4 •� {:,` ' «;. , , ft:\''.. .i o, ,.. , IN". • 1. , , ti,,_, 4mA FILL AREA IN FRONT OF BURNER WITH SMALL COALS 6 WALL SWITCH,REMOTE CONTROL OR THERMOSTAT OPERATION The Insert comes with an "ON-OFF" Rocker Switch located in the lower right hand corner of the surround. An optional Wall Switch,remote control or thermostat may be purchased to substitute for the Rocker Switch. A thermostat should be placed in the same room as the fireplace, approx. 4-5 ft. off the floor. Do Not place thermostat near the fireplace. Thermostat must be 460 to 750 Millivolt rated. An on-off wall switch or remote control may be used if Insert is not used primarily as a sup- plementary heat source. WHEN INSTALLED IN A SLEEPING AREA,A THERMOSTAT IS REQUIRED. NOTE: If thermostat is located over 25 ft. from the fireplace the pilot flame may need to be in- creased. CAUTION: BURNER SHOULD LIGHT IMMEDIATELY AFTER TURNING WALL SWITCH OR THERMOSTAT"ON". IF BURNER DOES NOT COME ON IMMEDIATELY TURN THE THERMOSTAT/WALL SWITCH OFF AND WAIT 60 SECONDS BEFORE TURNING ON AGAIN. IF BURNER DOES NOT COME ON IMMEDIATELY AFTER SECOND TRY RECHECK COMPLETE INSTALLATION OF LOGS,PILOT,ETC.TO INSURE PROPER PILOT FLAME IMPINGEMENT ON THE THERMOPILE AND PROMPT BURNER IGNITION. NEVER TURN BURNER ON& OFF "QUICKLY" -ALWAYS WAIT 60 SECONDS! When using remote control be sure to hold in button firmly until Insert lights. DO NOT push button and release quickly before Insert lights. Insert should light IMMEDIATELY and then button can be released. If Insert does not light immediately release button,wait 60 seconds and repeat lighting pro- cedure. Use two-wire,copper lead wire per chart and install as follows: THERMOSTAT (STANDARD) RECOMMENDED MAXIMUM REMOTE ON/OFF SWITCH OR WALL SWITCH LEADLENGTH(TWO-WIRE) THERMOCOUPLE WHEN USING WALL THERMOSTAT (CP-2 SYSTEM) 2 LEAD THERMOPILE WIRE SIZE MAX.LENGTH 14 GA. 100 FT. PILOT 16 GA. 64 FT. 18 GA. 40 FT. 20 GA. 25 FT. 22 GA. 18 FT. Nos I. L * II MAIN GAS VALVE THERMOCOUPLE WIRE THERMOSTAT WIRING DIAGRAM FIGURE 12 NOTE: Thermostat Must Be 325-750 Millivolt Rated CAUTION: THIS CONTROL IS A MILLIVOLT SYSTEM.NO ADDITIONAL POWER SUPPLY CAN OR SHOULD BE USED. 2 8 '' BURNER ttto.--5-- _--,_s.__i-_o—_-._---■._-_o-_■_i_s---•■-;-■7-- _ 1 1 WELDMENT : ER : 1 i ASSEMBLY .:. O L44-4 ti\. � i M a` �t �� �� REMOVABLE BURNER PAN r; 9© �� VALVE ASSEMBLY BURNER ORIFICE FIGURE 14 BLOWER(S)REMOVAL 1. Refer to FIGURE 14. Disconnect power to fireplace and blowers. 2. Remove door assembly, logs and coals. 3. Disconnect gas supply piping/tubing from gas valve. 4. Disconnect electrical connections at the Snapdisc thermostat by carefully pulling off wires connected to the Snapdisc thermostat. 5. Disconnect wiring connection between gas valve and ON/OFF switch or thermostat wire. 6. Remove 2 sheet metal screws that hold down the burner tube weldment; and remove burner. 7. Remove all sheet metal screws from Removable Burner Pan. Remove entire Burner Pan carefully and set aside. 8. Remove two Thumb Screws that secure the blower assembly to the unit floor. Blower as- sembly can now be removed through the rectangular access hole. Once blowers have been replaced or serviced, reassemble in reverse order. NOTE: Seal access plate with stove cement or 600°F RTV sealant before assembling in place. 3 0 I TROUBLE SHOOTING MENDOTA GAS FIREPLACE INSERT SYMPTOM PROBABLE CAUSES CORRECTIVE ACTION 1. Thin black coating[soot] A. Incorrect gas pressure Have gas supplier check for correct gas pressure[7"W.C. forms on viewing glass. Nat.Gas;11"W.C.LP Gas]. B. Not enough combustion air If sooting continues open-air shutter on burner[see"Gas Flame Adjustment"below]. If sooting still continues,call a Mendota dealer. NOTE: To clean glass-remove glass and wipe glass with cloth or paper towel. 2. Humming or whistling A. Normal operating noise. Some noise is normal. It is caused by the gas supply flow- coming from Fireplace In- ing through the gas orifice. It is expected from any gas sert. fireplace. The noise can be reduced by turning the Hi/Lo Knob on the control. Turning down the flame will reduce the heat output of the Insert. 3 A change in flame appear- A. A change in gas pressure. Have your gas supplier check for correct gas 7"W.C.Nat. ance or burner operation. Gas;1 I"W.C.LP Gas]. If flame still needs adjustment see "Flame Adjustment"below. B. Carbon dirt or lint. Clean out carbon,spider webs,lint,etc.from shutter area. NEVER BLOCK AIR INTAKE OR OUTLET VENTS. 0 m' CLOSE I .�� OPEN --- - /_ v - ��/a�A NSHUTTER li\ C ONTROL KNOB PUSH CLOSE UL OPEN FIGURE 15: Air Shutter Adjustment (Parts shown are for depiction purposes only.Your actual model may appear different than what is shown above) GAS FLAME ADJUSTMENT During the initial installation,the air shutter opening should be checked to be certain that the shutter is set cor- rectly at 1/8"to 1/4" open for natural gas and 1/2" minimum open for L.P. gas. NOTE: For altitudes above 5,000 ft.,some variations may be required. Be sure burner and logs are properly installed(see pages 20-27). After burner has been properly installed and operated for 2-3 hours, small additional adjustments to the air shutter may be necessary for final flame appear- ance. These small shutter adjustments can be made by the following procedure: [NOTE: Very small changes in shutter settings make maior changes in flame appearance.] 1. Air shutter control is located behind the lower grill. 2. If flame is too "blue,"push air shutter knob in (close) in small 1/8" increments until flame turns desired real- istic"orange." 3. If flame is too"orange"or is causing sooting on viewing glass,pull air shutter knob out(open)in approx. 1/8"increments until sooting stops. IF SOOTING DOES NOT STOP,TURN OFF UNIT AND CALL YOUR MENDOTA SERVICE PERSON. IMPORTANT: Try each new shutter setting approx. 'h hr.before making additional changes. NOTE: Changes in front burner flame can be made by re-arranging the coals and front burner air shutter opening. (See above.) 3 2 REPLACEMENT PARTS LIST MENDOTA GAS FIREPLACE INSERT - MODEL D-40 Deep Timber PART NO. DESCRIPTION HA-34-00007 Flat Door Assembly 65-06-00483 Glass Door Pane Flat HA-33-00031 Door Gasket Flat HA-34-00035 Bay Door Assembly 65-06-00582 Glass Door Pane Bay HA-33-00070 Bay Gasket Door HA-33-00071 Glass Gasket-Horizontal -(4 required) HA-33-00072 Glass Gasket-Vertical - (2 required) 35-01-00341 Deep Timber Log Set 35-01-00240 Bag of Coals 35-01-00234 Firebrick Kit 35-01-00239 Glowing Inswool (.6 oz Bag) 10-10-00104 On-Off Switch—Externally Mounted on Surround 65-06-00149 Piezo Igniter 05-02-00306 Main Gas Valve-SIT HA-34-00178 L.P. Kit HA-34-00187 Valve Assembly w/LP Conversion Kit-SIT 05-02-00283 Knob -On-Off Extension 10-10-00152 Rear Burner Rocker Switch 05-02-00284 Knob - Hi/Lo Regulator Ext. 05-02-00290 L.P. Pressure Regulator HA-27-0016 Front Orifice (Nat. Gas)#52 HA-33-00198 Rear Orifice (Nat. Gas) 7/64" HA-33-00191 Front Orifice (L.P. Gas) #57 HA-33-00190 Rear Orifice (LP. Gas) 1/16" 05-04-00036 Pilot Orifice (LP Gas) 05-04-00035 Pilot Assembly Complete - Nat. Gas 05-07-00061 Thermopile 05-07-00067 Thermocouple 10-01-00046 Rheostat 15-02-00064 Blower with Motor RH 15-02-00065 Blower with Motor RH 05-01-00157 Thermo-Disc(Snap Disc) 65-06-00125 Black Paint, 12 oz Aerosol Can 05-02-00308 Rear Burner Solenoid Valve-Concentric Control 35-01-00311 Large Chunk Coals WARNING: Use only authorized parts and materials obtained from Johnson Gas Appli- ance Company when replacing defective or damaged glass. DO NOT use glass from other suppliers as a replacement. DO NOT substitute other manufacturer's materials or components. DO NOT operate unit with cracked, broken or missing glass. DO NOT FORCE, STRIKE OR SLAM GLASS DOOR ASSEMBLY. 3 4 Figure 19 SAS VALVE B _ 3Y Qa - j s I :, �r �� PR - SS _ R - �,�.����:`��,of� f\`,or Q...=i ► 1 �. , .�►_� � c R _ E _ LAT - R \ \ 0 `\" �, e SCR _ WS • o o. 3 6 MENDOTA WARRANTY QUALIFICATION & SERVICE REFERENCE FORM As a part of Mendota's on-going program of customer satisfaction,this Form verifies proper installation and operation. It is important as a reference for future service.It insures long life and trouble-free operation of Mendota fireplaces&stoves and qualifies the owner for Mendota's lifetime limited warranty. Owner should sign Form when completed. Optionally,please register at our website at:WWW.JOHNSONGAS.COM/MENDOTA-REGISTRATION.ASP HOME OWNER: DEALER: ADDRESS: ADDRESS: CITY/STATE/ZIP: CITY/STATE/ZIP: SIGNATURE: PHONE: MODEL#: SERIAL#: DATE INSTALLED: GAS NAT or L.P. Mendota Fireplace Inserts are sophisticated,hi-tech gas appliances. All installation and operating instructions must be care- fully followed. The DXV fireplace must be installed and serviced by a qualified Mendota approved service person. REF: MENDOTA GAS FIREPLACE INSERT ❑ APPROVED VENT PIPES AND VENT CAP INSTALLED-Per Manual and manufacturer's specifications ❑ CHECK FOR PROPER CLEARANCES TO COMBUSTIBLES-Per pipe manufacturer's specifications ❑ INSTALL PROPER SIZE GAS LINES-CHECK FOR GAS LEAKS-Per Manual ❑ CHECK FOR CORRECT GAS PRESSURE AT MANIFOLD-Per Manual a. 3.5 Inches Water Column Maximum-Nat.Gas b. 10.5 Inches Water Column Maximum-L.P.Gas ❑ TAKE COMBUSTION SYSTEM MILLIVOLT READINGS [See Manual Pg.33] a. Pilot only-[Minimum millivolt 325] Reading: b. Main burner operating-[Minimum Millivolts 100] Reading: ❑ CYCLE BURNERS ON/OFF FOR PROMPT IGNITION-Per"LIGHTING INSTRUCTIONS" Burner must light IMMEDIATELY-Flame must travel promptly around"curve"&light burner. ❑ INSTALL LOGS AND ADJUST FLAME-Per Manual Proper pilot flame impingement on thermopile&burner-Air shutter opening: 1/8"- 1/4"Nat.Gas- 1/2"LP ❑ BRIEF OWNER ON OPERATION AND MAINTENANCE OF UNIT ❑ Light Pilot ❑ Operate Burner ❑Explain blower"delay"operation WARRANTY REGISTRATION Your Name Address City State Zip Dealer(Place of Purchase) City State Zip Date of Purchase Serial Number Purchaser's Signature MENDOTA FIREPLACE INSERT,_D-40 DEEP TIMBER CUT OUT PAGE AND MAIL TO: JOHNSON GAS APPLIANCE CO.,520 E AVE.N.W.,CEDAR RAPIDS,IOWA 52405 OR REGISTER YOUR NEW INSERT AT: WWW.JOHNSONGAS.COM/MENDOTA-REGISTRATION.ASP 3 8 F MENDOTA EXTENDED LIFETIME PROTECTION AND LIMITED WARRANTY MENDOTA GAS FIREPLACE INSERT MODEL: NAT.&L.P. Mendota Division of Johnson Gas Appliance Company,520 E Avenue N.W.Cedar Rapids,Iowa 52405,extends this Extended Lifetime Protection and Limited Warranty to the original purchaser of a Mendota Gas Fireplace Insert,Serial Number ,which is limited and used under normal home conditions. STANDARD WARRANTY: JOHNSON GAS APPLIANCE CO.,MENDOTA DIVISION,WARRANTS THAT YOUR NEW MENDOTA GAS FIREPLACE INSERT IS FREE FROM MANUFACTURING AND MATERIAL DEFECTS FOR A PERIOD OF ONE YEAR FROM THE DATE OF INSTALLATION,SUBJECT TO THE FOLLOWING CONDITIONS AND LIMITATIONS: EXTENDED LIFETIME WARRANTY: THE HEAT EXCHANGER,THE BURNER TUBE,THE COMBUSTION CHAMBER AND THE OUTER SHIELD OF THE MENDOTA GAS FIREPLACE INSERT ARE WARRANTED FOR THE LIFETIME OF THE ORIGINAL OWNER,SUBJECT TO PROOF OF PURCHASE AND THE FOLLOWING CONDITIONS AND LIMITATIONS: 1) This new Mendota Fireplace Insert must be installed and serviced by a competent,authorized service contractor. It must be installed and operated at all times in accordance with the installation and operating instructions furnished with the Fireplace. All adjustments to logs, coals or burner must be made by an authorized Mendota Service person. This limited warranty does not cover the cost of service calls,the cost of labor to remove or install parts covered by this limited warranty,freight or other transportation expenses that may be incurred in connection with obtaining performances under this limited warranty. The remedy for damages as the result of any defects in this product which have been warranted herein is limited to replacement parts and does not include any incidental,indi- rect or consequential damages or expenses sustained in connection with the products,including damages to property,except as provided by law. 2) This warranty is non-transferable and is made to the original retail purchaser,provided the purchase was made through an authorized Men- dota dealer. Mendota is not responsible for any damage to or malfunction of the Insert unless caused by a defect in material or workmanship from normal home use. Damage caused by abuse,improper installation or operation,installation by unqualified personnel or breach of the conditions of this limited warranty will excuse Mendota from performance of any part of the limited warranty. This warranty does not cover glass or log breakage. Mendota has the right to investigate and inspect the exact original fireplace and materials,in the event a claim is made(without alterations or tamper- ing),to determine whether the claimed damage or malfunction was caused by abuse,improper installation or other cause outside this warranty. Men- dota is not responsible for any repairs or material purchases that have not received prior written approval from Mendota. NOTE: Minor warping of certain parts or discoloration is normal and is not a defect covered by this limited warranty. Over-firing of your Mendota Fireplace Insert can cause major warping of parts. Over-firing above rated nameplate specifications is contrary to the manufacturer's instructions and WILL void this warranty. This warranty may not be extended by our representatives in any manner. The company neither assumes,nor authorizes any third party to assume,on its behalf,any other liabilities with respect to the sale of this Mendota product. 3) Mendota may at its discretion,fully discharge all obligations of this warranty by refunding the wholesale price of the defective part(s). 4) All other warranties-expressed or implied-with respect to the product,its components and accessories,or any obligation/liabilities on the part of the company are hereby expressly excluded. Products made by other manufacturers,sold with the Fireplace or thereafter,are not cov- ered by this limited warranty. The use of unauthorized components will make this warranty null and void. This warranty shall be effective only if the original purchaser of the Mendota appliance is registered with Mendota Division within thirty(30)days of the date of purchase. Such registration or the failure to register shall not be deemed to created any obligation or liability by the manufacturer and this warranty with its conditions and limitations shall be the only procedure for obtaining any rights against the manufacturer and expresses the sole obliga- tion and responsibilities of the manufacturer which are offered to the original purchaser and accepted upon purchase of the appliance. Mendota Division,reserves the right to make changes at any time without notice,in design,material,specifications,prices and the right to discontinue styles and products. Some states do not allow the exclusions of limitation of incidental or consequential damages or limitations on how long an implied warranty lasts,so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights,which vary from state to state. 4 2