HomeMy WebLinkAboutB15-0442 i � — lo � � 11-12-2015 Inspection Request Re orting Page 15 4:29 qm ----- ---�[ailrS�—�.itY�- --- — Requested Inspect Date: Friday,November 13,2015 Site Address: 1090 VAIL VIEW DR VAIL Unit 9 A/P/D Information Activity: 615-0442 Type: COMBO Sub Type: AMF Status: ISSUED Const Type: Occupancy: Use: R-2 Insp Area: Owner: MULVIHILL, DELPHINE K. Contractor: P FRAHM CONSTRUCTION INC Phone: 970-390-1002 Description: Replace wood fir lace,flue pipe and termination cap..In de dryall install at interior of fire chase.Minor framing non struct ral addition to accommodate new fire ox.O iginal fireplace has been removed by other party. Reauested Inspection(s) Item: 90 BLDG-Final �J Requested Time: 09:30 AM Requestor: Phone: Comments: 390�1002� Assigned To: ' Entered By: MHAEBERLE K Action: Ti E Item: 390 MECH-Final Req ed Time: 09:00 AM Requestor: Phone: Comments: 390�1002 Assigned To: ""' Entered By: MHAEBERLE K Action: Time Exp: Inspection Historv Item: 200 MECH-Rough *'Approved" 11/10/15 Inspector: JRM Action: AP APPROVED Comment: Item: 60 BLDG-Sheetrock Nail "Approved" 11/10/15 Inspector: JRM Action: AP APPROVED Comment: Item: 390 MECH-Final Item: 90 BLDG-Final REPT131 Run Id: 14670 -:� � � � � D i�=; �_:� � l ;� , � ' D '�. �l�- ��—, �..� � _ i � ��� � �' ���5 � � P -+�-p ;•;t�S� i-{�i���.��: . �O�PLi �t�: _m_ _ t�' - � -��� �� ' _ -..�_ x . ___,_..,r____.,._--.. a ..� <,���, j ✓ c $ ., � � ��i. * � $ � �n � 0 N � O M � O .--� .--� �' N M M 0 � � � z � U U c� � .�', � � 0 U C� � � 3 � � � � 0 � � a� � � � � � � � 0 U N bA c�3 � � N � O �, � � � � iow� of VaiB �� � � �� .�. ��R � � �;� � � .�.�� NOTE: TH/S PERM/T MUST BE POSTED ON JOBSITE AT ALL T/MES .• ��to�v�c � Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B15-0442 Project #: PRJ15-0630 Job Address: 1090 VAIL VIEW DR VAIL Applied.....: 10/30/2015 Location......: Unit 9 Issued. . . : 11/09/2015 Parcel No....: 210301409009 OWNER MULVIHILL, DELPHINE K. 10/30/2015 11 LINDWORTH DR ST LOUIS, MO 63124 CONTRACTOR P FRAHM CONSTRUCTION INC 10/30/2015 Phone: 970-390-1002 PETER FRAHM PO BOX 251 EAGLE CO 81631 License: C000004140 APPLICANT PETER FRAHM 10/30/2015 Phone: 970-390-1002 Description: Replace wood fireplace, flue pipe and termination cap. Includes dryall install at interior of fire chase. Minor framing non structural addition to accommodate new firebox. Original fireplace has been removed by other party. Occupancy: R-2 Type Construction: VB Valuation: $6,700.00 ...............................,,..........._......_....._..,,......._..,.,,...... FEE SUMMARY .._....,,.,..,,....,......,.«..,._....,_.......,,.....,............_...,....,.._. Building Permit-----------> $139.25 Bldg Plan Check----------> $90.51 Use Tax Fee-----------------------> $0.00 Electrical Permit---------> $0.00 Elec Plan Check-----------> $0.00 Restuarant Plan Review--------> $0.00 Mechanical Permit------> $80.00 Mech Plan Check---------> $20.00 Additional Fees--------------------> $0.00 Plumbing Permit--------> $0.00 Plmb Plan Check---------> $0.00 Recreation Fee--------------------> $0.00 Investigation-----------------------> $0.00 Will Call------------------------------> $10 00 TOTAL PERMIT FEES--------------> $339.76 Payments-------------------------------> 5339.76 BALANCE DUE------------------------> $0.00 .......................<...,....x,.....x.=....,,,,.......,..<..............��.......................,......,...x............._...................,.._....._....,.,....,................. DECLARATIONS I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM -4:00 PM. combination permit_012811 .. . � � i V���i �+ii�it 1 ..•x..+w+...xx..w+�+.:v.xxx..xrexx..,ee+s.�w.+wv.�x.+..s.s.s..x.+xxxx�..v.�xr.w:�xxw+er.+��xx,vrwv.x�xxwwv.��x,.rs.�we,.w�s..xw.w�x+.x+,r,r,.v.wwr.,vwv.wrr.x:rxx��:+�wv.�i�x,ewv.w�+x.,r:v,v,r:xxe+,r,r�x�:x,r�xr:+x CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit#: B15-0442 Address: 1090 VAIL VIEW DR VAIL Owner: MULVIHILL, DELPHINE K. Location: Unit 9 Yr�.F�,F�R��wttrtrk�kfwwYeA'�ff�w�,Fi1'4f1fRY'�k4ti4trw�k�41(wtkil'�RxM�kYl�hf�wkfrMYrffrfxil'iF�k4f1r1rYrkffxl�,1'rtltetefR�kYr�kAl4lrkYe�k4/it�ktrM'f1`frM#�kfi4leteYrYrM'fifM�R#Yffi4t�treff4ti4 V tri1'Y(4f�1rYrYl�kY(4f+tAit'kfk44trtrf�kf�4wA4firtk41�wRwwYrfl(fftrAitYfi}R combination permit_012811 ♦ � �f�V��� � .*****«.,«««**..***«««*«*..****«*****.****„*******.***,.«*««****«**,.*****«******,.*****,.****«**«********«*,.***«**,+**«,.*******.**********«***�*********** REQUIRED INSPECTIONS AND STATUSES Permit#: B15-0442 Address: 1090 VAIL VIEW DR VAIL Owner: MULVIHILL, DELPHINE K. Location: Unit 9 **„*.,*«««********«***********«,****,,,,,,*„««*************«***„««********,.***,,,,******««*******�**«««*****««*„**«*********«««**********„«««********.,***** Item: 00200 MECH-Rough Item: 00050 BLDG-Insulation Item: 00060 BLDG-Sheetrock Nail Item: 00070 BLDG-Misc. Item: 00390 MECH-Final Item: 00090 BLDG-Final combination permit_012811 ��\``'�� Department of Community Development 75 South Frontage Road TOWN OF VAIL � `'' � va�i,co s�ss� Tel: 970-479-2128 www.vailgov.com Development Review Coordinator BUILDING PERMIT APPLICATION (Separate applications are required for alarm &sprinkler) Project Street Address: Project#: ��l�'��3� 1090 Vail View Drive 9 ��r�` DRB#: ��J�'�VJ1� �� (Number) (Street) (Suite#) /, (.� Building/Complex Name: Telemark Town homes Building Permit#: � f� V� ` � - Contractor Information Lot#: Block# Subdivision: Business Name: P Frahm Construction, Inc Business Address: PO Box 291 Work Class: New(�j Addition(Qj Alteration(Q City Eagle State: CO Zip: 81631 Type of Building: Contact Name: Peter Frahm Single-Family�j Duplex(�j Multi-Family�j Commercial � Other�j Contact Phone: ��0-390-1002 Contact E-Mail: Peter@pfrahmconstruction.com Work Type: Interior� Exterior Q Both(�i I hereby acknowledge that I have read this application,filled out Valuation of in full the information required,completed an accurate plot plan, Work Included Plans Included Work and state that all the information as required is correct. I agree to Electrical �Yes �No QYes QNo comply with the information and plot plan,to comply with all Town ordinances and state laws, and to build this structure according to Mechanical �Yes Q)No OYes QNo 3500 the town's zoning bdivision codes, design review ap- proved, Intern � ilding and Residential Codes and other Plumbing �Yes OjNo �Yes �No ordinances t e n applicab o. 3200 �.�, Building OYes �No QYes �No X Value of all work being perFormed: $ 6700 Owner/ ner's Representative Signature(Required) (value based on IBC Section 109.3&IRC Section 108.3� Electrical Square Footage Applicant Information r Detailed Scope and Location of Work: �nstall new wood Applicant Name: �� , burning fireplace,flue pipe and termination cap. Applicant Phone: Includes,drywall install at interior of fire chase. Applicant E-Mail: Minor framing(non structural)addition to accommodate Project Information new firebox. Owner Name: MULVIHILL, DELPHINE K. Original fireplace was been removed by other party. Parcel#: 2103-014-09-009 (For Parcel#,contact Eagle County Assessors Office at(970-328-8640 or visit www.eag lecou�ty.uslpatie) (use additional sheet if necessary) For Office LJse Only: '�.� ._._._ _ _ . ._., Fee Paid: � �A� ' Date Receive , ; ;; � � =�'< �� � , �l'� ' �� ��� � . 1 Received From: I �'� '� 4 U� !� Cash Check# �D�� 3 � 2015 ,'� CC: Visa/MC Last 4 CC# exp date: �,f � Auth # " �`�..`.+�`�4�_ "`��" r.�.� _._ _., . . t2-Mar-2012 � INSTALLATION AND OPERATION INSTRUCTIONS u ertor SuperiorT"" Pro Series Cat Wood burning Firepiaces FI REPLACES" MODELS �� ��IIIIIIIIIIIIIIIIIIII�IIIIIIIIIIIIIII cPFS US WRT3836RS WCT3836RS WRT3836WS WCT3836WS �� P126625 01 WRT3836RSI WCT3836RS1 WRT3836WSI WCT3836WS1 P/N 126625-01 Rev. D 05/20/15 REPORT N0.10-078 WRT3836RH WCT3836RH WRT3836HWS WCT3836HWS SAVE THIS BOOK This book is valuable. In additian to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain replacement parts or accessory items when needed. Keep it with your ather important papers. INSTALLER: Leave this manual with the appliance. Installateur : Laissez cette notice avec I'appareil. CONSUMER: Retain this manual for future reference. Cor�sommateur:Conservezcette notice pourconsuRation ulterieure. This wood burning fireplace complies with UL127 Ce foyer au bois est conforme aux UL 127 CAN/ULC- CAN/ULC-S610-M87 standard as a FACTORY S610-M87 norme comme une USINE CONSTRUITE BUILT FIREPLACE. CHEMINEE. This fireplace is approved for use as a wood burning fireplace or for use with a vented gas log approved to ANSI Z21.60 or Z21.84 standards or for use with a vent-free gas log heater approved to ANSI Z21.11.2 standard.An INNOVATIVE HEARTH PRODUCTS, LLC hood must be installed when using a vent-free log heater(see Accessories, page 19). FOR CANADA: The authority having jurisdiction POUR LE CANADA: L'autorite competente (comme le (such as the municipal building department, fire service municipal du batiment, les pompiers, etc.) doit department, etc.) should be contacted before etre contacte avant I'installation afin de determiner la installatian to determine the need to obtain a permit. necessite d'obtenir un permis. These models meetthe EPA Wood Burning Fireplace Program Phase 2 emission level.NOTE:To ensure proper fireplace operation, the catalyst should he replaced at a minimum of 3 years and a maximum of 5 years. WARNING: If the information in these AVERTISSEMENT:Assurez-vous de bien suivre les instructions is not followed exactly, a fire or instructions donnees dans cette notice pour reduire au explosion may result causing property damage, minimum le risque d'incindie ou d'explosion ou pour eviter personal injury or death. tout dommage materiel, toute blessure ou la mort. — Do not store or use gasoline or other — Ne pas entreposer ni utilizer d'essence ni d'autres flammable vapors and liquids in the vicinity vapeurs ou liquides inflammables dans le voisinage of this or any other appliance. de cet appareil ou de tout autre appareil. — WHAT TO DO IF YOU SMELL GAS: — QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ : • Do not try to light any appliance. • Ne pas tenter d'allumer d'appareil. • Do not touch any electrical switch; do not • Ne touchez a aucan interrupteur. Ne pas vous use any phone in your building. servir des telephones se trouvant dans le batiment • Immediately call your gas supplier from ou vous trouvez. a neighbor's phone. Follow the gas • Appelez immediatement votre fournisseur de supplier's instructions. gaz depuis un voisin. Suivez les instructions du • If you cannot reach your gas supplier, call fournisseur. the fire department. • Si vous ne pouvez rejoindre le fournisseur de gaz, — Installation and service must he performed appelez le service des incindies. by a qualified installer, service agency or the — L'instalfation et I'entretien doivent etre assures par un gas supplier. installateur ou un service d'entretien qualifie ou par le fournisseur de gaz. For more information,visit Superiorfireplaces.US.com `/�(���� l � Thank you for your purchase. We appreciate your TABLE OF CONTENTS business! Safe Please carefully read and foi�ow all instructions in this manual. Pay �'������������-�������������������������������������������������������������������������������2 special attention to all warnings and safety information. Specifications.................................................................................4 Following these safery, care, and operation instructions will help Fireplace Installation......................................................................5 ensure many years of dependable and enjoyable service from your Venting Installation........................................................................7 fireplace. PureFire Hood Installation............................................................13 Register your product online today! Optional Gas Line Installation......................................................13 To help us keep you up-to-date on product information and Operation and Maintenance.........................................................14 offers, please take a few moments to register your product on- PureFire Emissions Control System.............................................15 line at Superiorfireplaces.US.com (Owner Resources/Product Replacement Parts List................................................................16 Registration). Accessories..................................................................................19 Please read and understand these instructions before installing Replacement Parts.......................................................................22 or operating. Technical Service.........................................................................22 Warranry...-•.................................................................................23 NATIONAL We recommend that our woodburning FIREPLACE hearth roducts be installed and serviced INSTITUTE' P by professionals who are certified in the U.S. 6y the National Fireplace institute"(NFI)as NFI Woodbuming Specialists or who are certified in Canada by 0 Wood Energy Technical �E�»mr CERTIFIED r«n��nn;�y ,,,,,,,,n�,,,;e�.�Training(WETf). -._•,.....• SAFETY A WARNING: Improper instaliation, adjustment, FOR YOUR SAFETY alteration,service or maintenance can cause injury, . Do not store or use gasoline or any other flammable property damage or loss of life. Refer to this manual vapors or liquids in the vicinity of this or any other for assistance or additional information. Consult a appliance. qualified installer or local distributor. • Due to high temperatures, the appliance should be IMPORTANT: Check local codes before installing this located out of traffic and away fram furniture and fireplace. draperies. • Da not place clothing or other flammable materials Before beginning installation of this fireplace,read these instructions on or near the appliance. through completely. • This INNOVATIVE HEARTH PRODUCTS, LLC (IHP) fireplace and • Never leave children unattended when a fire is its components are safe when installed according to this installa- bUl'ning In th6 fll'Bp18C8. tion manua�. Unless you use IHP components, which have been designed and tested for the fireplace system,you may cause a fire Q WARNING: Use SOlid WoOd or proCessed solid hazard. fuel fire logs only. "Do not poke or stir the logs while • The IHP warranty will be voided by and IHP disclaims any respon- they el'e bU1'lllllg. Use only firelogs that have been sibi�ity for the toi�owing actions. evaluated for the application in fireplace and refer to a. Modification of the fireplace, components,doors,air inlet firelog warnings and caution markings on packaging system and damper control. b. Use of any component part not manufactured or approved Prior to use." by IHP in combination with an IHP fireplace system. This flYeplBCe IS nOt intellded to be USed eS 8 SUb- Proper installation is the most important step in ensuring safe and stitute for a furnace to heat an entire home. Use for continuous operation of the fireplace.Consult the local building codes supplemental heat only. as to the particular requirements concerned with the installation of al1 factory built fireplaces. Ovefiring of a fireplace is a condition where exces- �WARNING: Do not install a fireplace insert in this sive temperatures are reached, beyond the design fireplace unless the manufacturer's instructions with capabilities of the appliance.The damage that occurs the insert specifically state this fireplace has been from ovefiring is not covered underthe manufacturer's tested for use with this insert. limited warranty. 2 Sup eri orfireplaces.U S.com 126625-01 D - SAFETY Continued A WARNING: CONTINUED OVERFIRING CAN PER- A WARNING: BURNING IMPROPER FUEL (I.E. MANENTLY DAMAGE YOUR FIREPLACE SYSTEM. CHARCOAL) CAN RESULT IN CARBON MONOXIDE SOME EXAMPLES OF CONDITIONS THAT COULD POISONING, WHICH MAY LEAD TO DEATH! CAUSE OVERFIRING ARE: Carbon Monoxide Poisoning — Early signs of carbon • BURNING QUANTITIES OF SCRAP LUMBER,PINE monoxide poisoning resemble the flu with headaches, BRANCHES, PAPER OR CARDBOARD BOXES dizziness, or nausea. If you have these signs, get WHICH EXCEED THE VOLUME OF THE NORMAL fresh air at once! Have the appliance inspected by a LOG FIRE. qualified service technician. Some people are more • BURNING TRASH, CHEMICALS OR CHEMICALLY affected by carbon monoxide than others. These TREATED COMBUSTIBLES. II1CIUde pCeJ11811t WO(11611, people with heart or lung "Disposal of Ashes disease or anemia, those under the influence of al- cohol, and those at high altitudes. Ashes should be placed in a metal container with a tight-fitting lid.The closed container of ashes should Ventilation Requirements - Provide adequate air for be placed on a noncombustible floor or on the ground, combustion. The fresh air requirements of this ap- well away from all combustible materials, pending P�iance must be met within the space where it will final disposal. If the ashes are disposed of by burial be installed. in soil or otherwise locally dispersed,they should be Smoke Detectors - Since there are always several retained in the closed container until all cinders have potential sources of fire in any home,we recommend thoroughly cooled." installing smoke detectors. If possible, install the "WHEN USING THE DECORATIVE APPLIANCE, THE smoke detector in a hallway adjacent to the room (to FIREPLACE DAMPER MUST BE SET IN THE FULLY reduce the possibility af occasional false activation OPEN POSITION." from the heat produced bythe appliance). Ifyaur local code requires a smoke detector be installed within the "Never use gasoline,gasoline-type lantern fuel,kero- same room,you must follow the requirements of your sene, charcoal lighter fluid, or similar liquids to start local code.Checkwith your local building department or 'freshen up' a fire in this fireplace. Keep all such for requirements in your area. liquids well awayfrom the fireplace while it is in use." "Creosote— Formation and Need for Removal Use SOLID WOOD only for fuel. It is best to use dry When wood is burned slowly,it producestarand other and well seasoned hardwood.Softwoods tend to burn veryquickly.DONOTusetreatedwood,charcoal,coal, organicvapors,whichcombinewithexpelledmoisture trash,driftwood orwoodsthat have been dipped intar, to form creosote. The creosote vapors condense in pitch, pine tar, creosote, etc. Wood products made the relatively cool chimney flue of a slow-burning with synthetic binders, such as plywood, produce ab- fire. As a result, creosote residue accumulates on narmally high temperatures and sputtering,smoking the flue lining. When ignited this creosote makes an fires. When burning artificial logs, please read and extremely hot fire. follow the instructions provided by the manufacturer. The chimney shall be inspected at least twice a Never burn treated construction lumber or scraps. Year during the heating season to determine when a These woods burn excessively hot and may contain creosote buildup has occurred. When creosote has chemicals used to treat insects and fungus. When accumulated(1/8"[3 mm]or more)itshall be removed burned,these chemicals can pose a significant hazard. to reduce the risk of a chimney fire." 126625-01 D Superiorfireplaces.US.com 3 SPECIFICATIONS RIGHT SIDE GAS LINE ELECTRICAL KNOCK 1"AtRSPACE OUTLET � �OUTS TO COMBUSTIBLE j� MATERIAL / � � �_ TOP NO COMBUSTIBLE � � � SPACERS MATERIAL ON FACE � � �_�[.� 9. �8�� — 7'/s" f f 8 3�4�� AIR KIT 11 ��a�� KNOCK OUT LEFT SIDE GAS LINE j COMBUSTIBLE KNOCK 3/4„ WALL BOARD OUTS AIR � �— + SPACE 11 ���s° � i � g��8,• BACK -� AND � 3 4� �� SIDES ; Q NOT LESS y 8 ��� OUTSIDE 0 �THAN 12"TO 14 �ts AIR(LEFT PERPENDICULAR SIDE ONLY) SIDEWALL HEARTH 0"TO � EXTENSION BOTTOM 8" EACH �51";X 16" � SIDE I--29"� —22" I � � � + �0 21" } 0 14 i�a�� � 12 ��2�� � � 32 ��2�� � � 41" ---� 5/8�� ROUND TOP TERMINATION i--1,� � 41 ��a��37� 21" SQUARE CHASE-TOP � TERMINATION $� � , � � I 35" { �{ 1° 41"--I 4 Superiorfireplaces.US.com 126625-01 D - FIREPLACE INSTALLATION SELECTING LOCATION To determine safest and most efficient location for fireplace, you must take into consideration the following guidelines: 1. Location must allow for proper clearances(see Figures 1 and 2). 2. Consider a location where fireplace will not be affected by drafts, air conditioning ducts,windows or doors. _ _ ,_ � � � 3. A location that avoids cutting of joists or roof rafters will make installation easier. r— — — � I f - - - - -I 413/a" I 4. An outside air kit is available with this fireplace (see 0 t� ional I I Outsitle Air Kit on page 7). I I ( MINIMUM CLEARANCE TO COMBUSTIBLES - - - - - - I r=_ =� . Back antl sides of fireplace 3/4"minimum" - - - - - Floor"` 0"minimum l � 21 �/8�I...� Perpendicular wal►to opening 14"minimum ~ 41 3/0"—►1 Top spacers 0"minimum Mantel clearances see Mantels,page 6 Figure 1-Framing Dimensivns Chimney outer pipe surface 1"minimum ' Not required at nailing flanges Maintain 3/4" " See step 2 of Framina Clearance at 17 5/,s" Sides and �WARNING: DO NOT PACK REQUIRED AIR SPACES Back of WITH INSULATION OR OTHER MATERIALS. 52 '/4^ Fireplace 24'/is" Minimum/Maximum Chimney Height Minimum height of chimney, measured from base of firepiace to flue gas outlet of termination, is 14.5 feet for straight flue or a flue with one elbow set.Maximum distance between elbows is 6 feet.For systems with two elbow sets,minimum height is 22 feet.Maximum height of any system is 50 feet.This measurement includes fireplace, 3/4" Clearance Not chimney sections and height of termination assembly at level of flue Required at Nailing Flanges gas outlet (see Figure 19, page 12). 73 �s�,s�� FRAMING 1. Frame opening for fireplace using dimensions shown in Figures Figure 2-Cnrner lnstallation 1 and 2. 2. If fireplace is to be installed directly on carpeting,tile(other than HEARTH EXTENSION ceramic) or any combustible material other than wood flooring, fireplace must be instailed upon a metal or wood panel e�ending A hearth extension projecting a minimum of 16" in front of and a full width and depth of fireplace. minimum of 8"beyond each side of fireplace opening is required to 3. Set fireplace directly in front of this opening and slide unit back protect combustibie floor construction in front of fireplace. Fabri- until nailing flanges touch side framing. cate a hearth extension using a material which meets the following 4. Check level of fire lace and shim with sheet metal if necessa specifications:a layer of noncombustible,inorganic material having p ry' a thermal conductivity of k = .84 BTU IN/FT2 HR °F (or less) at 1" 5. Before securing fireplace to prepared framing, ember protector thick. For example, if material selected has a k factor of 0.25, such must be placed between hearth extension (not included) and as glass fiber,the following formula wouid apply: under bottom front edge of fireplace to protect against giowing 0.25 x 1.0"=0.30"thickness required embers falling through. If fireplace is to be installed on a raised 0.84 platform,a Z-rype ember protector(not included)must be fabri- Thermal conductivity"k" of materials can be obtained from manu- cated to fityour required platform height.Ember protector should e�end under fireplace a minimum of 1 '/2'. Ember protector facturer or supplier of noncombustible material. If hearth extension should be matle of galvanized sheet metal (28 gauge minimum) is to be covered, use noncombustible material such as tile, slate, to prevent corrosion. brick,concrete,metal,glass,marble,stone,etc.Provide a means to 6. Using screws or nails,secure fireplace to framing through flanges Prevent hearth extension from shifting and seal gap between fireplace located on sides of fireplace. frame and hearth extension with a non-combustible material such as sand-cement grout(see Figure 3, page 6). i2ss25-oio Superiortireplaces.US.com 5 FIREPLACE INSTALLATION Continued A WARNING: Hearth extension is to be installed "Note: Drawing NotToScale onl as shown in Fi ure 3. f �2��4°Ref.-- Combustible Y 9 / Material � Safe Zone For Seal Gap 6� Projection of Fireplace Front � Ref. 33, ' Combustible Materials Non Combustibie Ember Protector/�— � 3"Nom�- Materials Below Top Spacer 15" � 1 '/z'�� Min. � Max. 9� � N� Hearth 12" Mi�n- Extension Min. � Do Not Block Louver Top of �y Upper Section �ouvered of Circulating Opening � Fireplace Fireplace Fron� Seal Gap Fireplace Opening–f Elevated Figure 4-Mantel Clearances tn Combustlble Material Ember Protector� Hearth Extension,Circulating Modes Combustibie �12'/;'Ref. Material Seal Gap Fireplace Front � � Safe 6,. Zone for Ref. Projection of Ember Protector� 33� Combustible Materials � 3"Nom. Fireplace Front Raised Hearth Hearth Extension 1'/z"Max.� Ember Protecto 12"Min. i Upper Fireplace Front Seal Gap 9"Min. Section of Elevated Firepiace � Ember Protector Fireplace Opening Hearth Extension,Noncirculating Models Figure 5-Mantel Clearances to Combustible Material(withnut touver) Figure 3-Hearth Extension —�–_ MANTELS FIREBOX A mantel may be installed if desired (see Figure 4).Woodwork such Top Vew of Fireplace as wood trims,mantels or any other combustible material projecting ____ __ from front face must not be placed within 9"of fireplace opening(and { 2��Max. within 9"of top louver opening).Combustible materials above 9"and SAFE ZONE ro ectin more than 1 '/2'from fire lace must not be laced less $ 3° P 1 9 P P 33� than 12"from top opening of fireplace(NFPA 211,Section-Clearance from Combustible Material). Mantels or any other combustible material may come up to side edge Min.12��from of black metal face of fireplace if projection from front face falls within Perpendicular Side Wall limits shown in Figure 5a. flgure 5a-Side Mantel Clearance 6 Sup eri orfireplaces.U S.com 12ss25-oi� VENTING INSTALLATION OPTIONAL OUTSIDE AIR KIT(MODEL AK4/AK4F) A WARNING:The opening in collar around chimney Installation of outside air kit should be performed during rough fram- at top Of firepleCe must nOt be ObStruCted. Never use ing of fireplace due to the nature of iYs location.Outside combustion blown insulation to fill chimney enclosure. air is accessed through a vented crawl space (AK4F} or through a sidewall (AK4). See Figure 6 for instruction of operating air kit. �2 3�8� Galvanized� A CAUTION: Combustion air inlet ducts shall not Outer Pipe � , terminate in attic space. �---' Hemmed End The maximum height for the air vent can not exceed a��Stainless _—, 3 feet helow the flue gas outlet of the termination. �""e`P'Pe ' Secure to Collars with Metal Tape,Screws or Straps(Min.of 1/4"x 20"in size) LINEAL GAIN CAT. N0. PART N0. DESCRIPTION GAIN 36" Fireplace 37'/2" Air�ntet F0895 12-8DM MusttAllow F0881 12-8HT Pipe Section 10 5/s" %, . For Busnes F0896 18-SDM ;��;1���; or Snow ° F0882 18-8HT Pipe Section 16 5/a" ,:t�,. �% -� ��" ° F0897 24-8DM Pipe Section 23 5/s" _ (( F0883 24-8HT F0898 36-SDM Pipe Section 34 5/8" � F0884 36-8HT Air�nlet vent Hood F0899 48-8DM 5 Eyebrow Required for F0885 48-8HT P�Pe Section 46 /e° Vented Crawl Space Wall Installation (Check Local Codes F0916 RT-8DM Round Termination 6'/s"� Before Installing in a RTL-SDM Round Termination 7 3/a"` Vented Crawl Space) Figure 6-Outside Air Kit F0918 RLT-8DM Round Termination 7'/2"� F0917 RTT-8DM Round Termination with 6'/a"to Sli Section 23'/a"' CHIMNEY PIPE Round Termination with 8'/z"to An IHP chimney system consists of 12", 18",24",36"and 4S"snap- RTTL-8DM Slip Section 21 '/z"` lock,double-wall pipe segments,planned for maximum adaptability Round Termination with 7'/2"to to individual site requirements. Actual lengths gained after fitting F0919 RLTT-8DM Slip Section 21 '/a"'` overlaps must be taken into consideration(lineal gain)and are given F0920 ET-SDM Square Chase-Top 12"" in lineal gain chart(see Figure 7). Lineal gain is actual measurable length of a part after two or more F0922 ETO-8DM Square Chase-Top with 12,,,, parts are connected.For Canada,use chimney parts designated"HT". Mesh F0921 ETL-8DM Square Chase-Top with 7°to 15""` Slip Section F0923 ETLO-8DM Square Chase-Top with 12"to Mesh &Slip Section 25'/2"" "The lineal gain for the terminations is measured to the flue gas outlet height. Figure 7-Lineal Gain 126625-01D Superiortireplaces.US.com � VENTING INSTALLATION Continued ASSEMBLY AND INSTALLATION OF DOUBLE WALL CHIMNEY Continue to assembie chimney sections as outlined, making sure SYSTEM that both inner and outer pipe sections are locketl togethec When Each double wall chimney section consists of a galvanized outer �nstalling double walt snap-lock chimney together, it is important to pipe,a stainless steel inner flue pipe and a wire spacer.Pipe sections assure joint between chimney sections is locked. Check by pulling must be assembled intlependently as chimney is installed. When chimneyupwardafterlocking.Chimneywillnotcomeapartifproperly connecting chimney directly to fireplace, inner flue pipe section locked. It is not necessary to add screws to keep chimney together must be installed first with lanced side up. Outer pipe section can (exception-see Figure 10, page 9). then be installed over flue pipe section with hemmetl end up.Press The height of a vertical chimney pipe supported ONLY bythe fireplace, down on each pipe section until lances securely engage hem on must not exceed 20 feet. Chimney heights above 20 feet must be fireplace starter. Wire will assure proper spacing between inner supported. and outer pipe sections. USING ELBOW OFFSETS(30E-8DM) Note:For Canada, use chimney parts designated HT. 1. To achieve desired offset, you may install combinations of 12", 18",24",36"and 48"length of double wall pipe (see offset chart � Opening in collar around chimney at top of and Figure 8). fireplace must not be obstructed. Never use blown Nvte:For systems with 2 elbow sets,minimum height is 22 feet. insulation to fill chimney enclosure. Maximum height for any system is 50 feet. 2. Chimney weight above offset rests on return elbow.Straps must be securely nailed to rafters or joists(see Figure 9,details A and B on page 9). 3. Maximum length of pipe between supports(return elbow or 12S- 8DM) is 6' of angle run. Maximum of two 6' angle run sections per chimney system (see Figure 8). 4. All pipe connections between offset and return must be secured with two screws on outer pipe only (see Figure 10, page 9). Do not penetrate inner stainless. Return Elbow Retum �Elbow Retum Offset Offset Elbow� Elbow 6'Max. Elbow\ 6'Max. \ Ceiling Retum Support Pipe Elbow� 12S-8DM 6'Max. � �Max. Retum � Elbow Otfset Offset � Offset Elbow 6'Max. Elbow 6'Max. �Elbow V � A � B � C Figure S- Typical Olfset lnstallation $ Superiortireplaces.US.com 1 2662 5-01 D VENTING INSTALLATION Continued See Detail A Ceiling Support Pipe 12S-8DM � 2"Min. � _ _ _ � � - - - - � See Detail B Straps� Straps St�ps Straps Detail A Detail B Return Elbow Angle Firestop Figure 9-Ceiling Support Pipe 12S-SDM OFFSET RISE CHIMNEY LENGTH A B 48�� 36�� 24�� 18�� 12�� 4 3/a" 16 3/a" ELBOW SET ONLY 9" 25 3/a" 1 11 '/s" 31" 1 15" 37 3/a" 1 16 3/a" 40 '/2" 1 1 20�� 4� ,�e�� 1 ZZ 5�8� rJZ 1I8� 1 1 25 '/2' 57'/8" 1 27 5/e' 62" 1 1 30 3Is" 67 1�4�� 1 1 33" 72 5/e" 1 1 3rJ 3I4� 78�� 2 37 '/e" 82" 1 1 1 screws� 41 '/a„ 88 5�8„ 1 1 � 43 3/s" 92 3/a" 2 1 ,• a 46 5/e„ 99 3�8„ 2 48 3/a" 103 '/2" 1 1 1 51 '/2' 108'/s" 2 1 54 '/a" 114 '/e" 2 1 57" 119 '/z" 1 2 � 59" �Z.� 5I8�� 2 1 1 � A �' 61 3I4� 129" 1 2 1 64 '/2' 134 3/a" 1 2 1 67 '/a" 139 5/a" 4 OFFSET CHART(22-50 FT.SYSTEM HEIGHT) Figure 10-Elbow Offset 126625-01D Superiortireplaces.US.com 9 VENTING INSTALLATION Continued FIRESTOP SPACERS(3600FS-8DM-1) Minimum Measurements Firestop spacers are required at each point where chimney penetrates �q 3�8' � a floor space. Their purpose is to establish and maintain required (36.5 cm) �„ I 30" clearance between chimney and combustibie materials.When pipe �2.5 (76.2 cm) passes through a framed opening into a living space above,firestop � must be placetl onto ceiling from below as shown in Figure 11. �m� ��� They also provide complete separation from one floor space to an- I (2.5 cm) other or attic space as required by most cotles. When double wall 1" I pipe passes through a framed opening into an attic space, firestop � (2.5 must be placed into an attic floor as shown in Figure 12. �---- cm) If area above is a living space,insta�l firestop I below framed hole. \ Opening"A" \�/ Pitch Slope Opening Used Flashing �.� "A" Max. Model No. 1 Fiat 0° 15" V6F-8DM i , 0-6/12 26.6° 16 '/a" V6F-8DM � 6J12- 12/12 45.0° 20 3/s" V12F-8DM Figure 11-Firestop Spacer with Living Space Above Ceiling Figure 13-Ronf Opening Measurements FLASH/NG INSTALLATION(V6F-8DM OR V12F SDM) If area above is an attic or insulated area,install firestop above tramed hoie. Determine flashing to be used with roof opening chart.Slide flashing over pipe until base is flat against roof.Replace as many shingles as needed to cover exposed area and flashing base. Secure in position � by nailing through shingles(see Figure 14).DO NOT NAIL THROUGH r FLASHING CONE. � Installing Flashing on a Metal Roof When installing flashing on a metal roof,it is required that putty tape be used between flashing and roof.Flashing must be secured to roof using#8 x 3/4"screws and then sealed with roof coating to prevent Figure 12-Firestop Spacer with Attic Space Above Ceiling leakage through screw holes. A roof coating must also be applied around perimeter of fiashing to provide a proper seal. PENETRATING ROOF To maintain a 1"clearance to pipe on a roof with a pitch,a rectangular Storm Collar� opening must be cut. o�ertap 1. Determine center point where pipe will penetrate the roof. � � Shingles Top 2. Determine center point of roof. Pitch is the distance the roof Flashing and Sides Only drops over a given span, usuaily 12". A 6/12 pitch means that Cone the roof drops 6"for each 12" measure horizontally down from Nail Only Outer � � f00f f3ftefS. Perimeter of � � `�' 3. Use roof opening chart(Figure 13)to determine correct opening Flashing ,o' o, length and flashing required. '° e ' 4. Remove shingles around opening measured.Cut out this section. °, 5. Add next sections of pipe until end penetrates roof line.Check to see �% that proper clearances are maintained.E�end chimney by adding sections of double wall pipe until pipe is minimum of 30"above Underlap Shingles highest point of roof cutout.Termination and chimney must extend at Bottom a minimum of 36"above highest point where it passes through roof. Figure 14-Flashing lnstallation io Superiorfireplaces.US.com 126625-01D VENTING INSTALLATION Continued Storm Collar installation(SC1) Place storm collar over pipe and siide down until it is snug against A CAUTION: Do not seal openings on the rooftop open edge of flashing(see Figure 15).Use SC1 for ali rountl termina- fleshing.FOIIOW the InSt8118t1011 i11Stl'UCtIOns pt'OVided tions.Apply waterproof caulk around perimeter of collar to provide with the termination heing used. a proper seal. Terminations with 16" slip pipe sections are available. RTT-8DM, cnimney waterproof RTTL-8DM and RLTT-8DM are approved for flashing installations. P'Pe Caulk When needed,these adjustable terminations may be usetl in combina- stor�, tion with pipe assembly to achieve correct chimney height. Collar Flashing Note:In the rare instance there is a problem with side driven rain or � wind or chimney is not drafting properly, an ADS-8DM (Anti-Draft Shield)can be used with round terminations. / RTL-8DM Attach Bracket � Level of Flue Figure 15-Storm Collar Tabs to Gas Outlet Outer Pipe Flue Pipe of Terminations/Spark Arrestor (3 Places) RTL-8DM Secure with Inside Inner Fireptace system must be terminated with listed round top or chase Screws � Pipe of terminations. In any case, refer to installation instructions supplied � a Chimney Overiap with termination. Terminations approved for this fireplace are RT- sn�n9ies ToP /Caulk 8DM,RTL-SDM and RLT-8DM that can be used for flashing or chase and Sides � Collar and ET-8DM,ETO-8DM,ETL-8DM and ETLO-8DM for chase sryle ter- mination only.Figure 17 shows an RTL-8DM round top termination. � i Flashing � � � � � � � � � � � � � � Underlap Shingles Bottom Only Figure 16- Termination 126625-01D Superiorfireplaces.US.com 11 VENTING INSTALLATION Continued CHASE INSTALLATIONS ��' --� �eve�of Instructions for chase installations are included with chase style ter- � OutleGas mination chosen. In a multiple chase instailation,be sure to provide �o� � adequate distance between terminations to prevent smoke spillage � � from one termination to another. We suggest that terminations be 2�Min. separated at least 24",center to center and stacked at a vertical height s'Min. difference of 18" (see Figure 17). �-- � 2'Min. Note:If a decorative shroud is to be installed,contact manufacturer _ 3'Min. for specifications. �I�I� ����a ����I BI� Figure 18- 10FootRule �IIII II�Pa �II 19 � ,8.. Min. FINISHING FIREPLACE TYP� Combustible materials, such as waliboard, gypsum board, sheet rock,drywall,plywood,etc.,may make direct contact with sides and ���I' �\ top around fireplace face. It is important that combustible materials �I��I� ����I � do not overlap face itself. Brick,glass,tile or other noncombustible materials may overlap front face provided they do not obstruct es- sential openings such as louvered slots. When overtapping with a 2a��nn�n. noncombustible facing material, use only noncombustible mortar or adhesive. 24"Min. EFFECTIVE HEIGHT EFFECTIVE HEIGHT OF TERMINATION CAP OF TERMINATION CAP Figure 17-Multiple Chase Installatian 10 FOOT RULE All flue gas outlet chimney terminations must extend a minimum of 3 feet in height above highest point where it passes through roof and MIN.HEIGHT must be at least 2 feet above highest point of the roof that is within OF 22 FT.(WITH a horizontal distance of 10 feet(see Figure 18). 2 e�sow sETS) MAX.HEIGHT OF 50 FT. MAX.HEIGHT 50 FT. EFFECTIVE HEIGHT EFFECTIVE HEIGHT (ANY SYSTEM) OF TERMINATION CAP OF TERMINATION CAP 14.5 FT. 14.5 FT. MINIMUM MINIMUM HEIGHT HEIGHT UP TO 6FT.MAX. UP TO 6FT.MAX. 30E-8DM 30E-8DM � � � � figure 19- Typical Residential lnstaHations 12 Superi orfireplaces.U S.com 126625-01 D _. PUREFIRE HOOD INSTALLATION 1. The PureFire hood supplied with this fireplace is packaged in a Hood separate box and placed in the firebox during shipping. � � F-- � 2. Remove hood from box. 3. Lift the hood up into the fireplace at an angle with the rear facing Refractory -- up.Set the front section of the hood on the refractory brackets. Reta�ner - Then tilt the rear toward the back of the fireplace so the hood is ��• resting on refractory brackets (see Figure 20).The rear of the �� hood will be touching the rear of the fireplace. ,�-- Figure 20-lnstalling PureFire Hood OPTIONAL GAS LINE INSTALLATION A gas line or gas log lighter may be installed for the purpose of 4. Repack insulation around gas line and into sleeve opening.Seal installing a vented or vent-free decorative gas appiiance incorporat- any gaps between gas line and refractory knockout hole with ing an automatic shutoff device antl complying with the Standard refractory cement or commercial furnace cement. Install gas for Decorative Gas Appliances for Installation in Vented Fireplaces, appliance or cap off gas line if desired. ANSI Z21.60 or American Gas Association draft requirements for Gas Fired Log Lighters for Wood Burning Fireplaces, Draft N0. 4 Outside of dated August, 1993. Fireplace If you wish to install an unvented (vent-free) gas log set, only Lne Incoming `°. iebrick unvented gas log sets which have been found to comply with the Conduit �i2"Black �• inished stantlartl for unvented room heaters,ANSI Z21.11.2 are to be installetl iron►�IPe ° ide in this fireplace. i� Gas line hook up should be done by your supplier or a qualified Repack � SeCViCe pefSOn. Insulation Seal . Note:Before you proceed,make sure your gas supply is turned off. �Ph""'9 �" Provide Enough Refractory �:°� Threaded End for Use only a 1/2"black iron pipe and appropriate fittings. o :. Fitting conneaion 1. Remove knockout intlentation on refractory or firebrick wall Cement located above refractory hearth floor.Knockout indentation must Figure 22-Gas Line lnstallativn be firmly tapped with any solid object,such as a 1/2"dowel,until it is released. Remove fragmented portions of refractory (see Fi9ure 21). A CAUTION:All gas piping and connections must be tested for leaks after installation is completed. After Outside of Fireplace Side ensuring that gas valve is on, apply soap and water � Firebrick Gas Line Finished solution to all connections and joints.Bubblesforming Conduit �o Side show a leak. Correct all leaks at once. DO NOT USE - AN OPEN FLAME FOR LEAK TESTING AND DO NOT . '�2 �We� OPERATE ANY APPLIANCE IF A LEAK IS DETECTED. Insulation LEAK TESTING SHOULD BE DONE BY A QUALIFIED Gas � � SERVICE PERSON. Conduit co�er •_o• Refractory Note:An IHP hood must be installetl when using an unvented gas Knockout log set(see Accessories on page 19). Plug Figure 2i-Gas Line Knockout 2. Remove gas line cover plate located on either side of fireplace and pull out insulation from gas line conduit sleeve.Save insulation for reuse. 3. Run a 1/2" black iron gas line into fireplace through rear at gas line conduit sleeve(if using a raised platform,add height). Provide sufficient gas line into fireplace chamber for fitting connection (see Figure 22). Note:Secure incoming gas line to wood framing to provide rigidiry for threaded end. 126625-01 D Superiortireplaces.US.com 13 OPTIONAL GAS LINE INSTALLATION Continued OPERATION AND MAINTENANCE Continued � WARNING: Do not operate an unvented gas log A"WARNING:FIREPLACES EQUIPPED WITH DOORS set in this fireplace with chimney removed. SHOULD BE OPERATED ONLY WITH DOORS FULLY If you install a decorative gas appliance(vented gas log),decorative OPEN OR DOORS FULLY CLOSED.IF DOORS ARE LEFT gas appliance must comply with the Standard for Decorative Gas PARTLY OPEN,GAS AND FLAME MAY BE DRAWN OUT Appliance for Installation in Solid Fuel Burning Fireplaces, ANSI OF THE FIREPLACE OPENING, CREATING RISKS OF Z21.60/CSA 2.26 or Z21.84 and shall also be installed in accordance BOTH FIRE AND SMOKE". with ANSI Z223.1/NFPA 54 National Fuel Gas Codes(USA)and CAN/ CGA-B149.1 National Gas And Propane Installation Code (Canada). �WARNING:To avoid the risk of damaging fireplace materials and increasing the risk of spreading a fire, Doors Fully Closed Fireplace Front do not use fireplace to cook or warm food. �WARNING: If the fireplace has been used for wood burning,firebox and chimney must be cleaned of soot, creosote and ashes be a qualified chimney cleaner. Creosote will ignite if heavily heated. 000�F,,,,y oPe�ed Fireplace Front � WARNING: When using a decorative vented gas Figure 23-Glass Donrs log, damper must be removed or permanently locked Cleaning Glass , in fully open position and glass doors must be in fully Clean glass with any commercial glass cleaner or soap and water. open position. Do not use any abrasive material to clean the glass. Do not clean glass with any cool water if glass is still hot from fire and smoke. OPERATION AND MAINTENANCE OUTSIDE DAMPER HANDLE OPERATION GLASS DOORS Damper handle,which opens and closes damper blade,is located in upper front face of fireplace.Pushing handle into left of keyway slot Glass doors are optional with this fireplace. When fireplace is in will free damper blade to automatically open. Pushing handle into operation, doors must be fully opened or fully closed position only right will lock damper blade closed (see Figure 24). Vent damper or a fire hazard may be created (see Figure 23). must be locked in the full open position before operating fireplace. Afireplace equipped with glass doors operates much differently than Outside air kit handle is located at left hand side of fireplace (see a fireplace with an open front. A fireplace with glass doors has a Figure 24). Pulling handle out will free outside air door to open. limited amount of air for combustion.Excessive heat within fireplace Pushing handle in will lock door closed. can result if too large a fire is built or if combustion air gate is not comp►ete�y open. � WARNING: Risk of fire! Replace grate with IHP The following tips should be used to assure that both fireplace and mode1125186-01 only.Thisgratehasbeendesignedto glass door retain their beaury and function properly. Both the flue keep the operation of your fireplace safe and efficient. damper and glass doors must be fully opened before starting a fire. This will provide sufficient combustion air and maintain safe Damper Handle temperatures in firebox. Keyway slot IMPORTANT The glass must be allowetl to warm slowly and evenly. � Tempered glass will withstand a gradual temperature rise to 550° --1 F,which is more than a normal fire will generate. Such materials as pitch/wax laden logs, very dry mill end lumber antl large amounts "�N.� of paper or cardboard boxes can create an excessively hot fire and should not be burned in this fireplace. Always keep fire back from �°�F doors and never allow flames to contact glass. D � Outside Air �� �� ^ Kit Handle Handle Retainer Figure 24-Damper and Air Kit Handle 14 Superi orfireplaces.US.com 126625-01 D PUREFIRE EMISSION CONTROL SYSTEM This fireplace is equipped with a PureFire Emission Control System. OPERATION The Catalytic Hood system reduces particulates emissions in a wood The proper use of a wood burning fireplace equipped with the catalyst burning fireplace to meet the EPA Wood-Burning Fireplace Program will significantly reduce the emissions that it produces. Simple fuel Phase 2 emission level. considerations with regard to moisture content,size,and quality of The EPA qualifying label,shown below,will be affixed to the catalyst. fuel will help control the production of wood smoke and improve the Before lighting the first fire, remove and maintain this label in a safe performance of the catalyst and fireplace efficiency.With proper care, place if needed for permits or building inspection.Prior to beginning the catalyst will provide years of fuel savings and lowered emissions. installation,contact your local building official to determine the need By following some simple guidelines, you will ensure maximum to obtain a permit. For proper operation, catalyst must be replace performance and longevity. every 3 to 5 years. The smoke that is usually seen coming out of a chimney is essentially FUELING GUIDELINES a combination of unburned fuel(carbon and hydrogen)and moisture The fireplace grate must always be secured to the retaining brackets in the form of water vapor.The catalyst is a technology that provides provided.The position of the grate must be centered againstthe back secondary combustion for the wood burning process. wall of the firebox. MAINTENANCE Burn only dry,seasoned(cured)wood with less than 20%moisture. The PureFire System is a maintenance free technology.Do not attempt Avoid the use of treated, painted and laminated wood. Never burn to remove or clean the combustor.The direct flame from the fire will garbage or other foreign materials.Do not use artificial logs,colored clean the combustor. Only a certified technician shouid remove the newspaper or petroleum based fire starters.Avoid wood with high unit.To ensure proper fireplace operation,the PureFire System should salt content. All of these materials may contain compounds which be replaced every 3 to 5 years(see Parts on page 17). can shorten the life of the catalyst. Wet or unseasoned wood may NOTE:Chimney smoke may be visible during the first 8 to 10 minutes lower catalytic temperatures and result in inefficient operation. of fireplace operation when the fire is first getting started and the The catalyst is designed to function at optimum efficiency when the final 8 to 10 minutes of operation while the fire is dissipating. Under fireplace is burning clean,dry,cord wood as fireplace fuel.A simple normal operating conditions,you should see little or no smoke com- visual inspection of the chimney during the wood burning process ing out of the chimney. If continuous smoke is visible, make sure will determine catalyst performance. only dry seasoned wood is being burned.If visible smoke continues, The fuel load should always be placed on the back of the grate. the combustor has ceased to function orthere is thermal crumbling. Use ciean dry wood, seasoned cord wood is the best choice. Never Please contact your IHP dealer for any questions or concerns.You burn trash,plastics,gasoline,rubber,industrial solvents,flammable can also visit our web site at Superiorfireplaces.US.com liquids,naptha,household garbage,material treated with petroleum WARRANTY products, leaves, paper products,cardboard or salt driftwood. IHP warranty obligations for the PureFire Emissions Control System Refer to your IHP Homeowner's Guide included with your fireplace are limited to the terms set forth below. for properfire building technique and ash removal procedures.These IHP warrants to the consumerwho purchases a new solid fuel burning fueling guidelines must be followed in order to achieve maximum fireplace containing a PureFire Emissions Controi System as a new emissions performance from the PureFire System. component,to replace the catalyst at no charge should it cease to function within three years from the date of purchase.The PureFire O Catalytic Component is designetl to perform efficiently forthree years of fireplace operation.ONLY recommended fuels should be burned. Follow the fueling directions in manufacturers operation manual.For U.S.Environmental Protection Agency warranty purposes, proof of fireplace purchases is required. Labor Wood-buming Fireplace Program for removal and/or installation of the catatytic component is not the ��=Q�����K�d�����������d=�� responsibility of the manufacturer. �,�����em�,��.�,�m��_����,� ��"'^�a^°°°��"�'"'"°�°°'�"°'�""'�e1a�� Neither IHP nor the dealer who sells the PureFire Emissions Con- m�m��,��,.�„�. Wrrpreinformatbngotowww.qw.gw/b�mwise trol System is responsible for indirect, incidental, special, punitive or consequential damages arising out of the improper use of this FIREPLACE product or the continued use of this product beyond the required SMOKE EMISSIONS RANGE �o�,Em��,o�s HigherEmissiorrs replacement period. Q ,2� e g 6.1 c.c�.cc,c,n.cc�n.z�Fvc� tRHw.�.��.U�F� ��ewa��w��n io.s�amuronc proa�ca recs cmom+.ren�nsviqa ana ow��ee c+owM� MsMFCCTIRF.R. 3MOV/1�tYE XFMM VRODUCts.1�� e�nOF1ND: M^WuaJ�vn�W Reyla H�1IiNalWmYp fLyY� PNlT16E N456101'6: l6(A4U6/16OF WOOD Blltl�� �V�WQ oDe+tbn.raol�R�m6 Oe��ISeO e�'vY 3 b 5 yeas. m 4surg Ey m acraihd�4e.paLL+�btrwunry ma e raWbtbn cwda��,xY N'a�ww�Y��9rhea cenlNnum nM'.MN tFis rtotld 9W'�"io f tic%ase 2 entce�e 1e.tl far us.ePAt wY�mry Freqx�e rmgrm. 126625-01D Superiorfireplaces.US.com 15 REPLACEMENT PARTS LIST WOOD BURNING FIREPLACE MODELS: MODEL CATALOG N0. � WRT3836RS F0671 �/ 29 WRT3836RSI F0672 � 2 WRT3836RH F0673 /� WCT3836RS F0674 I . I �; WCT3836RSI F0675 � WCT3836RH F0676 � �� � � WRT3836WS F0677 Z� � WRT3836WSI F0678 5\ WRT3836HWS F0679 $ . ' WCT3836WS F0680 . WCT3836WS1 F0681 ��\ 15 ��� WCT3836HWS F0682 28 � 20 .��- 30 • 2 • � � 18 11 36/37 9\ � 7 12\ � L( 3 � � � D 35 0 19 31 10 6 38 = � 13 � o 24 �4 33 �14 32 � 22 26 16/ 27 23� 16 27 16 Superiortireplaces.US.com 126625-01D � REPLACEMENT PARTS LIST Continued WOOD BURNING FIREPLACE MODELS This list contains replaceable parts used in your firepiace. A WARNING: Contact an IHP dealer to obtain any of these parts. Never use substitute materials not approved by IHP. Use of non-approved parts can result in poor performance and safety hazards. WRT3836RS WCT3836RS WRT3836RS1 WCT3836RS1 WRT3836RH WCT3836RH WRT3836WS WCT3836WS WRT3836WSI WCT3836WSI KEY N0. PART N0. DESCRiPTION WRT3836HWS WCT3836HWS QTY. 1 !106638-01 ;Insulation Pan • • 1 2 " ;Fireplace Top • • 1 3 !106641-01 :FireplaceSurround • - 1 4 106642-01 �Air Rod Retainer • • 1 5 :106643-01 ;Damper Rod Retainer • • 1 6 " Firebox Bottom • • 1 7 "" °Firebox Surround • • 1 8 " �AirSeparator • • 1 9 'See Page 17 �Left Refractory • • 1 10 �See Page 17 ;Right Refractory • • 1 11 ;See Page 17 Rear Refractory • • 1 12 See Page 17 �Bottom Rear Refractory • • 1 13 �See Page 17 Bottom Front Refractory • • 1 14 " firebox Support Leg • • 4 15 �106687-01 �Damper Can Collar - • 1 16 �106691-01 ;Screen Rod • • 2 17 " s Firebox Top Assembiy • • 1 18 '" 'Air Kit Door Assembly • • 1 19 " €Face Weldment • • 1 20 ;125562-01 Smoke Deflector • • 1 21 " Fireplace Top Insulation • • 1 22 �` �Access Panel • • 1 23 �107854-01 ;Right Refractory Bracket • • 1 24 ?107854-02 Left Refractory Bracket • • 1 25 �125186-01 'Grate • • 1 26 �11418 �Push-On Nut • • 2 27 ;12105 �Screen • • 2 28 '� Collar Insulation + • • 1 29 '20023 �Chimney Starter Coilar • • 1 30 :20027 Refractory Retainer • • 2 31 :23534 6rate Retainer • • 2 32 !20088 DoorStop • • 1 33 :20090 Spring Clip • • 2 34 '20280 ;Top Standoff • • 4 35 21171 ;Conduit Plate Cover • • 4 36 !21379 !Gas Conduit • • 2 37 21380 Gas Conduit • • 2 38 ;124994-01 :PureFire Catalytic Hood • , • 1 PARTS AVAILABLE-NOT SHOWN �20093 :Ember Protector 2 "` Not a field replaceable part 126625-01D Superiortireplaces.US.com » REPLACEMENT PARTS LIST Continued This list contains replaceable parts used in your fireplace. �WARNING: Contact an IHP dealer to obtain any of these parts. Never use substitute materials not approved by IHP. Use of non-approved parts can result in poor performance and safety hazards. HERRINGBONE LINER STACKED LINER MODEL CATALOG N0. WRT3836RS F0671 WRT3836RSI F0672 WRT3836RH F0673 WCT3836RS F0674 � WCT3836RSI F0675 WCT3836RH F0676 WRT3836WS F0677 WRT3836WSI F0678 WRT3836HWS F0679 WCT3836WS F0680 WCT3836WSI F0681 WCT3836HWS F0682 WRT3036WS WRT3036RS WRT3036WS1 WRT3036RSI WRT3036WH WRT3036RH WCT3036WS WCT3036HS PART N0. DESCRIPTION WCT3036WH WCT3036RH WCT3036WS1 WCT3036RSI QTY. :108164 01 Refractory, Left Herringbone White • : 1 i 108165 01 ;Refractory, Right Herringbone White • ; 1 ;108166 01 ;Refractory, Rear Herringbone White • ; 1 108167 01 ;Refractory, Bottom Rear White • ; 1 s 108168 01 i Refractory, Bottom Front White • ; 1 ;108164 02 'Refractory, Left Herringbone Retl • ; 1 108165 02 ;Refractory, Right Herringbone Red • ; 1 ;108166 02 �Refractory, Rear Herringbone Red • ; 1 108167 02 ;Refractory, Bottom Rear Red • : 1 '108168 02 ;Refractory, Bottom Front Red • � 1 :106658-01 !Refractory, LeftStacked White • ; 1 ;106659-01 �Refractory, Right Stacked White • y ;106660-01 ;Refractory, Rear Stacketl White � • ? 1 � ;106661-01 ;Refractory, Bottom Rear White ; • ; 1 :106662-01 ;Refractory, Bottom Front White • 1 ;106658-02 ;Refractory, Left Stacked Retl • ; 1 106659-02 Refractory, Right Stacked Red . � 1 106660-02 :Refractory, Rear Stacketl Retl . ; 1 ;106661-02 :Refractory, Bottom Rear Red . ; 1 ;106662-02 'Refractory, Bottom Front Red • ' 1 18 SuperioHireplaces.US.com 726625-01D ACCESSORIES CAT N0. MODE� DESCRIPTION BI-FOLD GLASS DOORS F0981 BD36 36"Standard Bi-Fold Glass Door- Black finish F0982 BD36B 36"Standard Bi-Fold Glass Door-Brushed Brass finish F0983 BD36P 36"Standard Bi-Fold Glass Door-Platinum finish DOUBLE WALL PIPE F0895 12-8DM 12"Section Double Wall Pipe Snap Lock F0896 18-8DM 18"Section Double Wall Pipe Snap Lock , � � , , F0897 24-8DM 24"Section Double Wall Pipe Snap Lock F0898 36-8DM 36"Section Double Wall Pipe Snap Lock F0899 48-8DM 48"Section Double Wall Pipe Snap Lock F0881 12-8HT 12"Section Hi-Temp Double Wall Pipe Snap Lock F0882 18-8HT 18"Section Hi-Temp Double Wall Pipe Snap Lock F0883 24-SHT 24"Section Hi-Temp Double Wall Pipe Snap Lock F0884 36-8HT 36"Section Hi-Temp Double Wall Pipe Snap Lock F0885 48-8HT 48"Section Hi-Temp Double Wall Pipe Snap Lock 30°OFFSET AND RETURN F0900 30E-8DM 30 Degree Offset and Return F0886 30E-8HT 30 Degree Hi-Temp Offset and Return OPTIONAL OUTSIDE AIR KIT FOR FLOOR INSTALLATION F1091 AK4 Complete Outside Air Kit w/Collars Hood &3' Flex � OPTIONAL OUTSIDE AIR KIT FOR SIDEWALL INSTALLATION � F1093 AK4F Outside Air Kit Collar, Hood &3' Flex for Floor Venting ,,,,,,,,,,,,�,,,,,, STORM COLLAR F0946 SC2-1 Storm Collar FIRESTOP SPACER F0907 3600FS-8DM-1 1"Clearance Firestop Spacer ROOF FLASHING F0908 V6FS-8DM Roof Flashing 0 to 6/12 Pitch (24"Base) F0909 V6F-8DM Roof Flashing 0 to 6/12 Pitch (30"Base) 126625-01D Superiortireplaces.US.com 19 ACCESSORIES Continued ANTI-DRAFT SHIELD (Round Top Termination Only) F0927 ADS-8DM Anti-Draft Shield for Round Top Only MESH ROUND TOP TERMINATIONS F0916 RT-8DM Round Top with Mesh Screen F0888 RT-8HT Ni-Temp Round Top with Mesh Screen RTL-8DM Round Top Termination 8" RTL-8HT Hi-Temp Round Top Termination LG. MESH ROUND TOP TERMINATIONS WITH SLIP SECTION F0917 RTT-SDM Round Top with Slip Section & Mesh F0889 RTT-8HT Hi-Temp Round Top w/Mesh Screen and Slip Section RTTL-8DM Round Top RTTL-8HT Hi-Temp Round Termination LG.with Slip Section ROUND TOP TERMINATIONS WITH LOUVERS F0918 RLT 8DM Round Top with Louvered Screen F0890 RLT-8HT Hi-Temp Round Top with Louvered Screen � �� ROUND TOP TERMINATIONS WITH LOUVERS W/SLIP SECTION ����� ���� F0919 RLTT-8DM Round Top with Slip Section & Louvers F0891 RLTT-8HT Hi-Temp Round Top w/Lvrd. Screen and Slip Section SQUARE TOP TERMINATION WITH LOUVERS F0920 ET-SDM Square Top F0892 ET-8HT Hi-Temp Pyramid Top with Slip Section SQUARE TOP TERMINATION WITH LOUVERS AND SLIP SECTION F0921 ETL-8DM Square Top with Slip Section �� � F0893 ETL-8HT Hi-Temp Large Pyramid Top with Slip Section MESH SQUARE TOP TERMINATION F0922 ETO-8DM Square Top with Mesh MESH SQUARE TOP TERMINATION WITH SLIP SECTION F0923 ETLO-8DM Square Top with Mesh and Slip Section ADJUSTABLEHOOD Re uired when installin a vent-free as lo in this fire lace. F1764 GA6050 Black Fireplace Hood / F1766 GA6053 Brushed Brass Fireplace Hood FIRESTOP THIMBLE F0911 38FST Firestop Thimble ( Use when penetrating a joist) F0912 FST30 Firestop Thimble (Use when offsetting through a joist) 20 Superiorfireplaces.US.com 126fi25-01D ACCESSORIES Continued Canadian code CAN/ULC-S610-M87 and other pertinent IMPORTANT NOTICE NOTICE: The firebox cano h00d codes require stainless steel chimneyforthe installation A manufactured shroud WhICh must not be modified or replaced with of this fireplace.A Cold Air Climate Kit is also required in Canada and is recommended for cooler regions in the has been approved by a na- a cano that ma 6e rovided with United 5tates. Below,find a list of approved stainless tional testing agency for US@ the unvented decorative room heater. Steei Pa"S. with this fireplace may be used CAUTION: THE STRUCTURAL INTEG- Chimney Parts list for Canada if installed in accordance with RITY OF THE MANUFACTURED HOME • • �� � I th@ instructions by ItS f11811U- FLOOR WALL AND CEILING ROOF � , "' � ' ' facturer. A locally fabricated MUST BE MAINTAINED. Fo881 ' � ;_�i 1 ;,z�tron Hi Temp Double ShfOUd 1118y be qSBd Wlth ��"�P Wall Pipe Snap Lock A WARNING: DO NOT INSTALL Fossz 18-SHT is°Section Hi-Temp Double Shroud Leg Spacer Kit (SLK) Wall Pipe Snap Lock in accordance with instructions �N SLEEPING ROOM OF MOBILE Fosas 24-8HT 2a°Section Hi-Temp Double provided with the shroud. HOMES. Wall Pipe Snap Lock Foss4 36-8HT ss"Section Hi-Temp Double IMPORTANT NOTICE A WARNING: Discontinue use Wall Pipe Snap Lock When penetrating a ceiling of the a�pliance immediately if F0885 48-SHT 48"Section Hi-Temp Double �nto an attic a firestop thimble doors are damaged and contact Wall Pipe Snap Lock � Fosss soE-sHT 30 Degree Hi-Temp Offset (38FST or FST30) is required a qualified installer for reQair. and Return to avoid intrusion by insulation Only doors certified with the F0887 12S-8HT Hi-Temp Chimney Support and recommended to negotiate apaliance shall be used. (Far Use With Chimney ^ Heights In Excess of 30') a )OISt. A WARNING: Do not slam or F0888 RT-SHT Hi-Temp Round Top with Mesh Screen strike doors. Damage can result F0889 RTT-8HT Ni-Temp Round Top with in a hazardous condition. Mesh Screen and Slip Sec- Thimble 38FST tion Or FST 30 F0890 RLT-8HT Hi-Temp Round Top with � Louvered Screen F0891 RLTT-8HT Hi-Temp Round Top with Louvered Screen and Slip Section F0892 ET-SHT Hi-Temp Pyramid Top with Slip Section � F0893 ETL-8HT Hi-Temp Large Pyramid Top Firestop with Slip Section(use with all S"systems) F0894 AP-8HT Hi-Temp Anchor Plate/Col- lar Assembly(for masonry fireplaces) F0929 CAK-8 Cold Air Collar Kit-8" Chimney "When ordered alone,this part cannot ship via parcel delivery services. 126625-01 D Superiortireplaces.US.00111 21 REPLACEMENT PARTS TECHNICAL SERVICE See Pages 16 to 18 for a complete replacement parts list. Use only You may have further questions about installation, operation, or parts supp�ied from the manufacturer. troubleshooting. Please contact your IHP dealer for any questions Normally, all parts shouid be ordered through your IHP distributor or concerns.When contacting your dealer please have your model or dealer. Parts will be shipped at prevailing prices at time of order. and serial numbers of your fireplace ready. You can also visit our web site at Superiortireplaces.US.com. When ordering repair parts,always give the following information: 1.The model number of the fireplace. 2.The serial number of the fireplace. 3.The part number. 4.The description of the part. 5.The quantity required. 6.The instailation date of the fireplace. If you encounter any problems or have any questions concerning the instailation or application of this fireplace,please contact your dealer. IHP 1508 Elm H111 Pike, Suite 108 Nashville,TN 37210 Visit us at Superiorfireplaces.US.com 22 Sup eri orfi replaces.U S.com 126625-01 D - _ I Innovative Hearth Products SuperiorT"' Brand Wood-Burning Fireplace 20 Year Limited Warranty THE WRRRANTY Innovative Hearth Products("IHP")20 Vear Limited Warranty warrants your Superior�"^Brand wood burning fireplace("ProducY')to be free from defects in materials and workmanship at the time of manufacture.The Product body,firebox and ceramic glass carry the 20 Year Limited Warranty.Ceramic glass carries the 20 Year Limited Warranty against thermal breakage onry.After installation,if covered components manufactured by IHP are found to be defective in materials or workmanship during the 20 Year Limited Warranty period and while the Product remains at the site of the original installation,IHP will,at its option,repair or replace the covered components.If repair or replacement is not commerciaily practical,IHP witl,at its option,refund the purchase price or wholesale price of the IHP product,whichever is applicabie.IHP will also pay IHP prevailing labor rates,as determined in its sole discretion,incurred in repairing or replacing such components for up to five years.THERE ARE EXCLUSIONS ANO LIMITATIONS to this 20 Year Limited Warranty as described herein. COVERAGECOMMENCEMENT DATE Warranty coverage begins on the date of installation.In the case of new home construction,warranty coverage begins on the date ot first occupancy of the dwelling or six months after the sale of the Product by an independent IHP dealer/distributor,whichever occurs earlier.The warranry shalt commence no later than 24 months following the date of product shipment from IHP,regardless of the installation or occupancy date. EXCLUSIONS AND LIMITATIONS This 20 Year Limited Warranty applies only'rf the Product is installed in the United States or Canada and only if operated and maintained in accordance with[he printed instruc- tions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices. This warranty is non-transferable and eMends to the original owner only.The Product must be purchased through a listed supplier of IHP and proof of purchase must be provided.The Product body and tire6ox carry the 20 Year Limited Warranty from the date of installation.Vent components:trim components,paint and applied siains are excluded from this 20 Year Limited Warranty.The following do not carry a 20 Year Limited Warranty but are warranted as foliows: Air tuhes,haffies and brick retainers—Repair or replacement for one year from the date of installation Cast iron parls—Replacement for one year from date of installation Catalyst—Carries a separate warranty.Refer to the warranty certificate provided tor that part Electrical camponents—Repair or replacement for one year from the date of instailation Fireplace screens,refractory and side shields(meial or refractnry)—ReDair or replacement for two years from date of installation.Excludes hairline cracks. Fuel grates—These parts are considered consumable accessories and therefore are not warran[ed,with the exception of defects in material or workmanship which are covered for 90 days from the date of installation Gaskets—Replacement for one year from date of installation Gold&nickel plating—Replacement for two years from date of installation.Excludes tarnishing Optional glass doors—Repair or replacement for 90 days from the date of installation flefractory&screens—Replacement for two years from date of installation.Excludes hairline cracks Remova6le air tu6es—Repair or replacement for seven years trom date of installation.IHP prevailing labor rates for years one through five. Labor coverage—Prevailing IHP labor rates apply for the warranty period of the component. Parts not otherwise listed carry a 90 day warranty from ihe date of installation. Whenever practica6fe,IHP will provide replacement parts,it available,tor a period af 10 years fram the last date ot manufacture af the Product. IHP will not be responsible for.(a)damages caused by normal wear and tear,accident,riot,fire,flood or acts of God;(b)damages caused by abuse,negligence,misuse,or unauthorized alteration or repair of the Product affecting its stabiliry or pertormance.(The Product must be subject to normal use with approved fuels listed in the Operation Manual provided with the product.This includes burning such firepiace fuels as wood and natural or propane pas.Fuel products with abnormal burning characteristics, including but not limited to fuel such as driftwood,coal or plywood and wood products using a binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly.);(c)damages caused by failing to provide proper maintenance and service In accordance with the instructions provided with the Product;{d)damages,repairs or inefficiency resulting from fauity installation or appiication of tbe Product. Coverage of this 20 Year Limited Warranty is conditional upon use of an adequate fuel grate on factory-built fireplaces only,when applicable. IHP is not responsible for inadequate fireplace system draft caused by air conditioning and heating systems,mechanical ventilation systems,or general construction condi- [ions which may generate negative air pressure in the room in which the appliance is instailed.Additionally IHP assumes no responsibility for smoking conditions caused by inadequate chimney height,adjoining trees or buildings,adverse wind conditions or unusual environmental factors and conditions.Certain IHP Products are listed for use with Securiry Chimneys intemational,Ltd.or IHP chimney systems only.Use ot chimney components other than that specified in the Product manual will void the Product warranry. This 20 Year Limited Warranty covers only parts and labor as provided herein.In no case shall IHP be responsible for materials,components or construction which are not manufactured or supplied by IHP or for the labor necessary to install,repair or remove such materials,components or construction.Additional utilily bflls incurred due to any malfunction or defect in equipment are not covered by this 20 Year Limited Warranly.All replacement or repair components will be shipped F.O.B.from the nearest stocking IHP factory. LIMITATION ON LIABILITY It is expressly agreed and understood that IHP's sole obligation and the purchaser's exclusive remedy under this warranty,under any other warranty,expressed or implied,or in contract,tort or otherwise,shaii be limited to repiacement,repair,or refuntl,as specified herein. In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product,whether such damage occurs or is discovered before or after replacement or repair,and whether such damage is caused by IHP's negligence.IHP has not made and does not make any representation or warranty of fitness for a particular use or purpose,and there is no implied condition of fitness for a particular use or purpose. IHP makes no expressed warranties except as stated in this 20 Year Limited Warranty.The duration of any implied warranty is limited to the duration of this expressed warranty. No one is authorized to change this 20 Year Limited Warranty or to create for IHP any other obligation or liability in connection with the Product.Some states and provinces do not allow the exclusion or limitation of incidental or co�sequential damages,so the above limitations or exclusions may not appiy to you.The provisions of this 20 Year Limited Warranty are in addition to and not a modiffcation of or subtraction from any statutory warranties and other rights and remedfes provided by law. INVESTIGATION OF CLAIMS AGAINST WARRANTY IHP reserves the right to investigate any and all claims against this 20 Year Limited Warranty and to decide,in its sole discretion,upon the method of settlement. To receive the benefits and advantages described in this 20 Year Limited Warranty,the appliance m�st be insialled and repaired by a licensed contractor approved by IHP. Contact IHP at the address provided herein to obtain a listing of approved deaters/distributors.IHP shall in no event he responsi6le for any warranty work done 6y a contrac- tor that is not approued without first ahtaining IHP's prior written consent. HOW TO RE6ISTER A CLAIM AGAINST WARRANTY In order for any claim under this warranty to be valid,you must contact the IHP dealerldistributor from which you purchased the product.If you cannot locate the dealer/ distributor,then you must notify IHP in writing.IHP must be notified of the claimed defect in writing within 90 days oi the date of failure.Notices should be directed to the IHP Warranty Department at 1508 Elm Hill Pike,Suite 108;Nashville,TN 37210 or visit our website at WWW.SUPERIORFIREPLACES.US.COM. Printed in U.S.A.OO 2013 Innovative Hearth Products LlC Innovative Hearth Products P/N 900224-00, Rev. NC 12/2013 1508 Elm Hill Pike, Suite 108•Nashville,TN 37210 WARRANTY KEEP THIS WARRANTY Model Number Serial Number Date Installed Dealer's Name Dealer's Phone Number Keep receipt for warranty verification IHP reserves the right to make changes at anytime,without notice,in design,materials,specifica- ��� tions,prices and also to discontinue colors,styles and products.Consult your local distributor for fireplace code information. ' � I)IIIIIIIIIIIIIII�IIII'IIIIIIIIIII'�I�I INNOVATIVE HEARTH PRODUCTS P126625 O1 Printed in U.S.A.O 2013 IHP LLC PM 126625-01 Rev.D 05/2015. 1508 EIIII HIII PIkC, Suite 108•Nashville,TN 37210