Loading...
HomeMy WebLinkAboutB11-0496 REV15 Penetration Firestop Report (� PCL Construction Services Inc. x NewSubmittal �� �� Submittal Cover Sheet Date: g�31/15 Resubmittal Project: Strata-Vail To: OZ Architecture From: PCL Construction Services,inc. Submittal No• 07841-04 3003 Larimer Street 953 S Frontage Rd West Contractor Project No:5001410 ' Denver,CO 80205 Suite 302 vaii,co si6s� Previous Submittal No: SPECIFICATION SECTION NO.&DESCRIPTION (Cover only one section with each submittal) 07841 - Through Penetration Firestop System CONTRACT REF.DOCUMENT PRIORITY STATUS CODES ACTION TAKEN Description of Item Submitted Spec Paragraph Drawing Sheet A-Immediate Response A-APProved Item (Type,size,model number,etc.) Submittal Type Number Number B-Respond within 7 days B'Approved as Noted C-Revise and Resubmit e. f. C-Respond within 10 days a. b. c. D-Not Approved 1 Shop Drawings-RK Engineering Judgement Action 1.3 C-Respond within 10 days 2 3 4 5 6 7 8 9 10 CONTRACTOR REMARKS: A/E REMARKS: CONTRACTOR'S CERTIFICATION: I certify that the above submitted items have been reviewed in detail,are correct,and in general conformance with the Contract Drawings and Specifications except as otherwise noted. NAME AND SIGNATURE OF CONTRACTOR REPRESENTATIVE: Received by: Date: Heather Wrozek CONSTRUCTION LEADERS Strata - Vail PCL Proiect No. 5001410 Subcontractor: Date: 8/31/15 Submittal#: 07841-04 Revisions: Revision Oates: Specification Section: 07841 Item Description: Through Penetration Firestop System Action: Variance Request(Y/N): If so, why?: Notes: Notes to OZ Architecture and design reviewers include: - Please find the attached Engineering Judgement from Hilti.Submittal catergory is"Action". - Submittal includes one EJ drawing Transmittal of Submittal rk echanical August 31, 2015 PCL Construction Services, Inc. 2000 South Colorado Blvd, Tower Two, Suite 2-500 Denver, CO 80222 Attention: Chuck Kay Project Engineer Reference: Strata Vail 705 West Lionshead Circle Subject: Submittals for Specification Section 15400 Dear Chuck: RK Mechanical, Inc. is providing PCL Construction Services, Inc. the enclosed submittals for Specification Section 15400 -THROUGH PENETRATION FIRESTOP SYSTEM, as listed below: ITEM COPIES REV SUBMITTAL DESCRIPTION STATUS DUE BACK 1 1 1.3 Sho Drawin s-RK/Hilti En ineerin Jud ement For Review 09/14/2015 Your immediate review and processing is requested to ensure these submittals are returned back to RK Mechanical, Inc. on or before the DUE BACK date(s) listed above. We are available to discuss any comments or questions you may have concerning these submittals. Sincerely, RK Mechanical, Inc. Justin Burkhardt xc:RK Job#4009- Main Files 3800 Xanthia Street Denver, Colorado 80238 ph: 303.355.9696 fx: 303.355.8666 www.rkmi.com Submittal Cover Sheet rk echanical Date Submitted: August 31, 2015 Date Due Back: September 14, 2015 RK Submittal No.: 07841 - 04 Specification Section: 15400 -THROUGH PENETRATION FIRESTOP SYSTEM Project Name: Strata Vail 705 West Lionshead Circle General Contractor: PCL Construction Services, Inc. 2000 South Colorado Blvd, Tower Two, Suite 2-500 Denver, CO 80222 Mechanical Contractor: RK Mechanical, Inc. 3800 Xanthia Street Denver, CO 80238 Subcontractor/Supplier: ITEM COPIES REV SUBMITTAL DESCRIPTION DRAWING MANUFACTURER 1 1 1.3 Shop Drawin s-RK/Hilti En ineerin Jud ement Hilti 3800 Xanthia Street Denver, Colorado 80238 ph: 303.355.9696 fx: 303.355.8666 www.rkmi.com All Hilti EJ's/FCD's are designed in accordance with the International Firestop Counsel ("IFC")guidelines. These EJ's/FCD's are designed by our experienced degreed fire protection technicians using, as the basis for our opinion: ■ relevant 3rd-party testing in accordance with ASTM E-84, ASTM E-119, ASTM E-136, ASTM E- 814, ASTM E-1966,ASTM E-2307, CAN/ULC-S115-11, UL 263, UL 723, UL 1479,UL 2079, or ASTM E-2837 ■ wide-ranging related internal testing of our firestop products, and ■ extensive knowledge and experience of the performance characteristics of Hilti firestop products, and firestopping technology generally. Pursuant to IFC guidelines, each EJ/FCD is intended for one specific jobsite, since even slight variances from one application to the next can affect system performance. Best regards, Fire Protection Engineering Team Corporate Engineering Hilti North America 3701 W.Royal Lane,Suite 100 I Irving,TX, 75063 P 1-800-879-8000 I F 918-254-1679 E usfirestopeng@hilti.com www.us.hilti.com/firestop If you desire not to receive commercial electronic messages(CEMs)from this sender, please reply with"unsubscribe"in the subject line. 2