HomeMy WebLinkAboutB15-0452- - - 1 __ _ --- _ •— w _ .yam ---- --- — - _— I - % -T 1 L. - a. f - - " y
FIRST SUPPLEMENTAL MAP TO
'POTATO PATCH CLUB CONDOMINIUMS
SHEET 4 of 5 k
SECOND FLOOR 1' � 10' L—
L
FIRW FLOOR I'-10'
LOWER LEVEL 1"-10'
eWINEERDJC I ffUKVCYING, DJC. RR SM 1015 MAIL COLORADO
� SOP/
�Ca `kvd
,,
e m
l I'^c_e VV vVpv JC_ K_T_ t
1W.
v-L� w'
w:{n, of Vail
REVIEWED FOR CODE
COMPLIANC
Date:-.
Code:
6UILDINC- SECTIONS
I* = 10"
v ezw.m'
UNIT 23 n
. ezzc.e+• L �Ev ers,.mi,e
�v. Bm641'
C•C
E -E
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657
p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149
COMBINATION BLDG PERMIT
Job Address: 950 RED SANDSTONE RD VAIL
Location......: Potato Patch Unit 24
Parcel No....: 210106306024
OWNER POTATO PATCH LLC 11/09/2015
PO BOX 518
EVERGREEN, CO
80439
APPLICANT FIREPLACE WAREHOUSE ETC
ASAHELHERNANDEZ
3827 STEELE ST
DENVER
CO 80205
License: C000004177
CONTRACTOR FIREPLACE WAREHOUSE ETC
ASAHELHERNANDEZ
3827 STEELE ST
DENVER
CO 80205
License: C000004177
Permit #: B15-0452
Project #: PRJ15-0657
Applied.....: 11/09/2015
Issued...: 12/10/2015
11/09/2015 Phone: 303-717-0553
Description:
Install Gas Fireplace - Wood to Gas Conversion
11/09/2015 Phone'. 303-717-0553
Occupancy: R-2 Type Construction: VB
Valuation: $4,200.00
..................«..,...............,,............,,...........,..........,..,, FEE SUMMARY.....,..,_...........,,.,........,.............,,,,........,,..........,...,..
Building Permit ----------->
$111.25
Bldg Plan Check ---------->
$72.31
Use Tax Fee----------------------->
$0.00
Electrical Permit --------->
$0.00
Elec Plan Check ----------->
$0.00
Restuarant Plan Review-------->
$0.00
Mechanical Permit ------>
$100.00
Mech Plan Check --------->
$25.00
Additional Fees-------------------->
($308.56)
Plumbing Permit -------->
$0.00
Plmb Plan Check --------->
$0.00
Recreation Fee-------------------->
$0.00
Investigation----------------------->
$0.00
Will Call ------------------------------ >
$5,00
TOTAL PERMIT FEES-------------->
$5.00
Payments ------------------------------- >
$5.00
BALANCE DUE ------------------------ >
$0.00
DECLARATIONS
I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure
according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and
other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149
OR AT OUR OFFICE FROM 8:00 AM - 4:00 PM.
combination permit_012811
f
i v W NaFvnI L
CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF
Permit #: B15-0452
Owner: POTATO PATCH LLC
Potato Patch Unit 24
combination permit_012811
Address: 950 RED SANDSTONE RD VAIL
Location:
TOWN OF VA Li
REQUIRED INSPECTIONS AND STATUSES
Permit #: B15-0452
Owner: POTATO PATCH LLC
Potato Patch Unit 24
Item:
00200 MECH-Rough
Item:
00240 PLMB-Gas Piping
Item:
00290 PLMB-Final
Item:
00390 MECH-Final
Item:
00090 BLDG -Final
combination permit -012811
Address: 950 RED SANDSTONE RD VAIL
Location:
6!1
TOWN OF VAIL
Department of Community Development
75 South Frontage Road
Vail, CO 81657
Tel: 970-479-2139
www.vailgov.com
BUILDING PERMIT APPLICATION
(Separate applications are required for alarm & sprinkler)
Project Street Address: Project #: F 6-T i 5 o h�) i
Number DRB #:
(Number) (Street) (Suite #)
Building/Complex Name:
Contractor Information
Building Permit#: '66'. Dq_5J
Lot #: Block # Subdivision:
Business Name: ��"eap�k�e W-1r-Wus,_ e, -c
I- I
.._.__--- __.__-_— _--
Business Address: 3g 27 Serie Sk -
Work Class: New ( ) Addition ( ) Alteration X
City Lnay -State: CO Zip: 8��s
Type of Building:
Contact Name: ik0se l �--1tMy� ,C(R.Z
Single -Family ( ) Duplex ( ) Multi -Family (�/s
Commercial( ) Other(
Contact Phone: 3D3 . 717. 0 S" -3
Contact E -Mail: tt5a�1�\.a is �4w hS ,
Work Type: Interior ( ) Exterior ( )Both
I hereby acknowledge that I have read this application, filled out
Valuation of
Work included Plans Included Work
in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to
Electrical ( )Yes ( )No ( )Yes ( )No
comply with the information and plot plan, to comply with all Town
ordinances and state laws, and to build this structure according to
,/u
'Mechanical (Yes ( )No ( )Yes ( )No y i fl0'
the town's zoning and subdivision codes, design review ap-
proved, International Building and Residential Codes and other
Plumbing ({)Yes ( )No ( )Yes ( )No
ordinances of the Town applicable thereto.
Building ( )Yes ( )No ( )Yes ( )No
X
Value of all work being performed: $
(value based on IBC Section 109.3 & IRC Section 108.3)
Owner/dwners Representative Signature (Required)
Electrical Square Footage
Applicant Information
Detailed Scope and Location of Work: -J,^5 -k.►J1�w
LcA,,
1, _
Name: �nk-_fez
` l x -L i ,I
blt-6 y� tet'
Applicant Phone: 303 . -7 V? . Dzrr�
Applicant E -Mail: ti� eel �. �" S • Goin .
NGW p\q 5 `iM c�.n c-�u �cSVti 4yv�t l i
Project Information
Owner Name: �Lt-(..
3 - 6 0114
\
wS \ire iS ovFS�� 7' 3�`' 1gZ . 1 `►'1io
Parcel #: a101 - 06 0 -
(For Parcel #, contact Eagle County Assessors Office at (970-328-8640 or visit
'%A VY,Q� �-C.4" 16 Ct,- -1-4
www.eaglecounty.us/patie)
(use additional sheet if necessary) �O g�S �vScr 1
For Office Use Only:
Fee Paid:
Received From:
Cash Check #
CC: Visa / MC Last 4 CC #
Auth #
exp date:
v l
Date Received:
n NOV 0 9 1015
TOWN OF VAIL
4 r1c ,
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.22, ANSI Z21.50 FOR VENTED GAS FIREPLACES.
CFRTIFIFn FnR (',ANAnA ANI) I INITFn RTATFR I ISINC. ANSI/CRA MFTHnnR X I R4 1 N
SAFETY INFORMATION
AWARNING
If the information in these instructions
are not followed exactly, a fire or
explosion may result causing property
damage, personal injury or loss of life.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Immediately call your gas supplier from a
neighbour's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the
fire department.
- Installation and service must be performed by a
qualified installer, service agency or the supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certified kit is used.
Decorative Product: Not for use as a heating appliance
Qh
Il 111 filllllll lhl�l'V III'lII III VII IIIIIII IIII IIf'fl
NATURAL GAS
XI R4-1 P
PROPANE
HOT GLASS WILL CAUSE
BURNS.
DO NOT TOUCH GLASS UNTIL
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
A barrier designed to reduce the risk of burns from the
hot viewing glass is provided with the appliance and
shall be installed.
=pew Q Iiry Srsl—Certified Ta
v°
Also
9001-2008
$10.00 1.36D
W415-1194 / A / 12.19.13
2
TABLE OF CONTENTS
ftThe
camera icon indicates video tutorials are available as additional reference, visit http://
www.napoleonfireplaces.com/category/product-support/support-centre/
1.0
INSTALLATION OVERVIEW
3
2.0
INTRODUCTION
4
2.1 DIMENSIONS
5
2.2 MINIMUM CLEARANCE TO COMBUSTIBLES
5
2.3 GENERAL INSTRUCTIONS
5
2.4 GENERAL INFORMATION
6
2.5 RATING PLATE INFORMATION
7
3.0
INSTALLATION
8
3.1 LEVELLING THE APPLIANCE
8
3.2 CHIMNEY CONNECTION
9
3.3 GAS INSTALLATION
10
4.0
FINISHING
11
4.1 MINIMUM MANTEL CLEARANCES
11
4.3 NON-COMBUSTIBLE FACING MATERIAL
12
4.2 DOOR REMOVAL / INSTALLATION
12
4.4 LOG PLACEMENT
13
4.6 BATTERY INSTALLATION
14
4.7 GLOWING EMBERS
15
4.8 LOGO PLACEMENT
15
5.0
ELECTRICAL INFORMATION
16
5.1 WIRING DIAGRAM
16
6.0
OPERATION
17
6.1 OPERATING AND LIGHTING INSTRUCTIONS
17
6.2 GENERAL TRANSMITTER LAYOUT
18
6.3 APPLIANCE OPERATION
18
6.4 HAND HELD REMOTE OPERATIONS
18
6.5 TEMPERATURE DISPLAY
19
6.6 ROOM THERMOSTAT
19
6.7 SMART THERMOSTAT
19
6.8 FLAME HEIGHT
20
6.9 CHILD PROOF FUNCTION
20
6.10 NIGHT LIGHT
20
6.11 LOW BATTERY / MANUAL BYPASS
21
6.12 IN THE EVENT OF A POWER FAILURE
21
6.13 CONTROL MODULE
21
6.14 SPLIT FLOW VALVE
21
6.15 ANTI CONDENSATION CONTROL SWITCH (OPTIONAL)
22
6.16 TIMED BLOWER
22
7.0
ADJUSTMENTS
22
7.1 PILOT BURNER ADJUSTMENT
22
7.2 VENTURI ADJUSTMENT
23
7.3 FLAME CHARACTERISTICS
23
8.0
MAINTENANCE
24
8.1 ANNUAL MAINTENANCE
24
8.2 CARE OF GLASS
25
8.4 CARE OF PLATED PARTS
25
8.3 DOOR GLASS REPLACEMENT
25
8.6 FCM REPLACEMENT
26
8.5 BURNER REMOVAL
26
8.7 NIGHT LIGHTT' REPLACEMENT
27
8.8 VALVE TRAIN REPLACEMENT
27
9.0
REPLACEMENTS
28
10.0
OVERVIEW
29
11.0
ACCESSORIES
31
12.0
VALVE TRAIN ASSEMBLY (W010-3028)
32
13.0
TROUBLESHOOTING
33
14.0
WARRANTY
36
15.0
SERVICE HISTORY
37
16.0
NOTES
38
NOTE: changes, other than editorial, are denoted by a vertical line in the margin.
W415 -1194/A/ 12.19.13
J
1.0 INSTALLATION OVERVIEW
Rating Plate, see "RATING
PLATE INFORMATION"
section.
N
Venting, see "INSTALLATION
- CHIMNEY CONNECTION"
Logs, see "FINISHING - LOG
PLACEMENT' section.
Batteries must be disposed of according to the local laws and regulations. Some batteries may be recycled,
and may be accepted for disposal at your local recycling center. Check with your municipality for recycling
instructions.
W415-1194 / A / 12.19.13
11
2.0 INTRODUCTION
WARNING
THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED.
ANY CHANGES OR ALTERATIONS TO THIS APPLIANCE OR ITS CONTROLS CAN BE DANGEROUS AND
IS PROHIBITED.
Do not operate appliance before reading and understanding operating instructions. Failure to operate appliance
according to operating instructions could cause fire or injury.
Risk of fire or asphyxiation do not operate appliance with fixed glass removed.
Do not connect 110 volts to the control valve.
Risk of burns. The appliance should be turned off and cooled before servicing.
Do not install damaged, incomplete or substitute components.
Risk of cuts and abrasions. Wear protective gloves and safety glasses during installation. Sheet metal edges may
be sharp.
Do not burn wood or other materials in this appliance.
Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid
burns or clothing ignition.
Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young
children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there
are at risk individuals in the house. To restrict access to an appliance, install an adjustable safety gate to keep
toddlers, young children and other at risk individuals out of the room and away from hot surfaces.
Clothing or other flammable material should not be placed on or near the appliance.
Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
Ensure you have incorporated adequate safety measure to protect infants/toddlers from touching hot surfaces.
Even after the appliance is out, the glass and/or screen will remain hot for an extended period of time.
Check with your local hearth specialty dealer for safety screens and hearth guards to protect children from hot
surfaces. These screens and guards must be fastened to the floor.
Any safety screen, guard or barrier removed for servicing the appliance, must be replaced prior to operating the
appliance.
The appliance is a vented gas-fired appliance. Do not burn wood or other materials in the appliance
It is imperative that the control compartments, burners and circulating blower and its passageway in the appliance
and venting system are kept clean. The appliance and its venting system should be inspected before use and at
least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from
carpeting, bedding material, etc. The appliance area must be kept clear and free from combustible materials,
gasoline and other flammable vapors and liquids.
Under no circumstances should this appliance be modified.
This appliance must not be connected to a chimney flue pipe serving a separate solid fuel burning appliance.
Do not use this appliance if any part has been under water. Immediately call a qualified service technician to
inspect the appliance and to replace any part of the control system and any gas control which has been under
water.
Do not operate the appliance with the glass door removed, cracked or broken. Replacement of the glass should
be done by a licensed or qualified service person.
Do not strike or slam shut the appliance glass door.
When equipped with pressure relief doors, they must be kept closed while the appliance is operating to prevent
exhaust fumes containing carbon monoxide, from entering into the home. Temperatures of the exhaust escaping
through these openings can also cause the surrounding combustible materials to overheat and catch fire.
• Only doors / optional fronts certified with the appliance are to be installed on the appliance.
• Keep the packaging material out of reach of children and dispose of the material in a safe manner. As with all
plastic bags, these are not toys and should be kept away from children and infants.
• As with any combustion appliance, we recommend having your appliance regularly inspected and serviced as
well as having a Carbon Monoxide Detector installed in the same area to defend you and your family against
Carbon Monoxide.
• Ensure clearances to combustibles are maintained when building a mantel or shelves above the appliance.
Elevated temperatures on the wall or in the air above the appliance can cause melting, discolouration or damage
of decorations, a T.V. or other electronic components.
• A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall
be installed.
• If the barrier becomes damaged, the barrier shall be replaced with the manufacturer's barrier for this appliance.
• Installation and repair should be done by a qualified service person. The appliance should be inspected before
use and at least annually by a professional service person. More frequent cleaning may be required due to
excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners and
circulating air passageways of the appliance be kept clean.
3.2C
W415-1194 /A / 12.1 q 1-4
2.1 DIMENSIONS
241/2" mmei 1
[622mm] 213!8"
241/4" [543mm]
[616mm] 11"
[27 ill,
— 11 1/2"
[292mm]
16 5/8"
[422mm]
2.2 MINIMUM CLEARANCE TO COMBUSTIBLES
5
This appliance must be recessed into a vented noncombustible wood -burning appliance (prefabricated or masonry)
only. The minimum appliance opening size in which the appliance is to be installed is:
HEIGHT 25" (635mm) WIDTH 34.25" (870mm) DEPTH 17" (432mm)
The minimum allowable chimney flue size is 7" (178mm) round.
The minimum distance, from the bottom of a combustible mantel projecting 3" (76mm) maximum from the wall
to the top of the appliance, is 14" (356mm) (see "MINIMUM MANTEL CLEARANCES" section).
2.3 GENERAL INSTRUCTIONS
&JK4WARNING
ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT,
WITH THE GLASS DOOR OPENED OR REMOVED.
PROVIDE ADEQUATE CLEARANCE FOR SERVICING AND OPERATING THE APPLIANCE.
PROVIDE ADEQUATE VENTILATION.
NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE.
OBJECTS PLACED IN FRONT OF THE APPLIANCE MUST BE KEPT A MINIMUM OF 48" (1219mm) FROM
THE FRONT FACE OF THE APPLIANCE.
SURFACES AROUND AND ESPECIALLY ABOVE THE APPLIANCE CAN BECOME HOT. AVOID CONTACT
WHEN THE APPLIANCE IS OPERATING.
FIRE RISK. EXPLOSION HAZARD.
HIGH PRESSURE WILL DAMAGE VALVE. DISCONNECT GAS SUPPLY PIPING BEFORE PRESSURE TESTING GAS
LINE AT TEST PRESSURES ABOVE 1/2 PSIG. CLOSE THE MANUAL SHUT-OFF VALVE BEFORE PRESSURE
TESTING GAS LINE AT TEST PRESSURES EQUAL TO OR LESS THAN 1/2 PSIG (35 mb).
USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH THIS APPLIANCE.
USING NON -LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS COMPONENTS, VENTING
COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL VOID THE WARRANTY AND CERTIFICATION.
THIS GAS APPLIANCE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to
conform with local codes. Installation practices vary from region to region and it is important to know the
specifics that apply to your area, for example in Massachusetts State:
• This product must be installed by a licensed plumber or gas fitter when installed within the commonwealth
of Massachusetts.
• The appliance damper must be removed or welded in the open position prior to installation of a appliance
insert or gas log.
• The appliance off valve must be a "T" handle gas cock.
• The flexible connector must not be longer than 36 inches (914mm).
• A Carbon Monoxide detector is required in all rooms containing gas fired appliances.
• The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent
sealed combustion product.
W415-1194 / A / 12.19.13
X
The installation must conform with local codes or, in
absence of local codes, the National Gas and Propane
Installation Code CSA B149.1 in Canada, or the National
Fuel Gas Code, ANSI Z223.1 / NFPA 54 in the United
States. Suitable for mobile home installation if installed in
accordance with the current standard CAN/CSA Z240MH
Series, for gas equipped mobile homes, in Canada or
ANSI Z223.1 and NFPA 54 in the United States.
NATIONAL
FIREPLACE
We suggestour g that as
INSTITUTE
hearth products be installed
04,500
Max. Input (BTU/HR)
40,000
serviced by professionals
ILIand
33,200
who are certified in the U.S.
Efficiency (w/the fan on)
83%
by the National Fireplace
A.F.U.E. (maximum value)
79%
Institute° (NFI) as NFI Gas
CERTIFIED
Specialists
www.nhcerti5ed.org
Max. Inlet Gas Supply Pressure
Some appliances have optional fans or blowers. If an optional fan or blower is installed, the junction box must
be electrically connected and grounded in accordance with local codes, use the current CSA C22.1 Canadian
Electrical Code in Canada or the ANSI/NFPA 70 National Electrical code in the United States.
4.12A
2.4 GENERAL INFORMATION
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST -FIRED TO ASSURE ITS OPERATION AND
QUALITY!
W415 -1194/A/ 12.19.13
NG LP
Altitude (FT)
0-4,500
04,500
Max. Input (BTU/HR)
40,000
40,000
Max. Output (BTU/HR)
33,200
33,200
Efficiency (w/the fan on)
83%
83%
A.F.U.E. (maximum value)
79%
79%
Min. Inlet Gas Supply Pressure
4.5" Water Column
(11 mb)
11" Water Column
(27mb)
Max. Inlet Gas Supply Pressure
7" Water Column
(17mb)
13" Water Column
(32mb)
Manifold Pressure (Under Flow Conditions)
3.5" Water Column
(9mb)
10" Water Column
(25mb)
W415 -1194/A/ 12.19.13
7
When the appliance is installed at elevations above 4,500ft (1372m), and in the absence of specific
recommendations from the local authority having jurisdiction, the certified high altitude input rating shall be
reduced at the rate of 4% for each additional 1,000ft (305m). Expansion / contraction noises during heating up
and cooling down cycles are normal and to be expected.
This appliance is not approved for closet or recessed installations. It is approved for bathroom, bedroom and
bed -sitting room installations and is suitable for mobile homes. The natural gas model is suitable for installation
in a mobile home that is permanently positioned on its site and fuelled with natural gas.
Canada
ENERQUIDE
Gas Fireplace Energy Efficiency Rating
6809%
Based on CSA P.4.1-02
Model No. X I R4-1
2.5 RATING PLATE INFORMATION
CERTIFIED UNDER / HOMOLOGUE SELON LES NORMES: CSA 2.22, ANSI 221.50 FOR VENTED GAS FIREPLACES / FOYER AGAZVENTILE.
DO NOT TURN ON IF CHILDREN OR OTHER AT RISK INDIVIDUALS ARE NE PAS ALLUMER SI DES ENFANTS OU 11 AUTRES INDIVIDUS A RISQUE SORT A
NEAR THE FIREPLACE. DIRECT VENT GAS FIREPLACE. SUITA13LEuL%I6Y PROXIMITE DU FOYER. FOYER A GAZ VENTILE. HOMOLOGUE POUR INSTALLATION
FOR BEDROOM, BATHROOM AND BEDSITTING ROOM INSTALLATION. DANS UNE CHAMBRE ACOUCHER, UNE SALLE DE BAIN ET UN STUDIO.
SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI SON
ACCORDANCE WITH THE CURRENT STANDARD CAN/CSA Z240MH INSTALLATION EST CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH
SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA OR IN THE sP SERIE DE MAISONS MOBILES EQUIPEESAU GAZ. EN VIGUEUR AU CANADA, OU
UNITED STATES THE MANUFACTURED HOME CONTRUCTION AND """'° AUX STATS-UNIS. SELON LA NORME DE SECURITE ET DE CONSTRUCTION DE
SAFETY STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US T4ArIPtu MAISONS MANUFACTUREES. TITRE 24 CFR. SECTION 3280. DANS LE CAS OU
STANDARD IS NOT APPLICABLE USE THE STANDARD FOR FIRE CERTIFIED FOR CETTE NORME DES ETATS-UNIS NE PELT ETRE APPLIQUEE. SE REFERER A LA
SAFETY CRITERIA FOR MANUFACTURED HOME INSTALLATIONS, CANADA USA NORME RELATIVE AT CRRERE DE MESURES DE SECURITE CONTRE UINCENDIE
SITES AND COMMUNITIES, ANSI / NFPA 501A. FOR USE WITH CERTIFIES POUR POUR LES INSTALLATIONS DANS LES MAISONS MANUFACTUREES, LES SITES ET
BARRIER W565-0134. FOLLOW THE INSTALLATION INSTRUCTIONS REFERENCE #161746 LES COMMUNAUTES ANSU4FPA 501A. POUR UNE UTIUSER AVEC BARRIERE
LOCATED IN THE INSTALLATION MANUAL W565-0134. SUMEZ LES INSTRUCTIONS D'INSTALLATION BE TROUVENT DANS LE
MANUEL D'INSTALLATION.
Natural Gas/Gaz Natural
Propane
XIR4N ❑ CXIR4N ❑ MODEL -] XIR4P L] CXIR4P
4500FT(0-1370m) ALTITUDE/ELEVATION 450OFT(0-1370m)
40,000 BTU/h INPUT ALIMENTATION 40,000 BTU/h
16,000 BTU/h REDUCED INPUT%ALIMENTATION REDUITE 15,000 BTU/h
MANIFOLD PRESSURE: 3.5' WATER COLUMN MANIFOLD PRESSURE: 10' WATER COLUMN
PRESSION AU COLLECTEUR: 3.5' DUNE COLONNE O'EAU PRESSION AU COLLECTEUR: 10"D UNE COLONNE D'EAU
MINIMUM SUPPLY PRESSURE: 4.5' WATER COLUMN MINIMUM SUPPLY PRESSURE: 11" WATER COLUMN
PRESSION 0 ALIMENTATION MINIMALE: 4.5' D'UNE COLONNE D'EAU PRESSION D'ALIMENTATION MINIMALE: 11' D'UNE COLONNE D'EAU
MAXIMUM SUPPLY PRESSURE: 7.0' WATER COLUMN MAXIMUM SUPPLY PRESSURE: 13- WATER COLUMN
PERSSION D'ALIMENTATION MAXIMALE: 7.O' D'UNE COLONNE D'EAU PERSSION D'ALIMENTATION MAXIMALE: 13' DUNE COLONNE D'EAU
P4: 68s% P4: 68.9'6
HIS VENTED GAS FIREPLACE IS NOT FOR USE WITH AIR CE FOYER A GAZ VENTILES NE DOIT PAS ETRE UTILISE
FILTERS. FOR USE WITH GLASS DOORS CERTIFIED FOR THIS CONJOINTEMENT AVEC DES FILTRES A AIR. UTILISER AVEC LES
UNIT ONLY. NOT FOR USE WITH SOLID FUEL. PORTES VITREES HOMOLOGUEES AVEC CETTE UNITE SEULE-
WARNING: Do NOT ADD ANY MATERIAL TO THE APPLIANCE THAT WILL COME IN MENT. UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE
CONTACT WITH THE FLAMES, OTHER THAN THAT SUPPLIED BY THE MANUFACTURER AVEC CET APPAREIL.
WITH THE APPLIANCE. AVERTISSEMENT: N'A JOUTEZ PAS A CET APPAREIL AUCUN MATERIAU DEVANT
DECORATIVE PRODUCT: NOT FOR USE AS A HEATING APPLIANCE. ENTRER EN CONTACTAVEC LES FLAMMESAUTRE QUE CELLI QUI EST FOURNIAVEC CET
ELECTRICAL RATING: 115V 1.SAMP 60HZ APPAREIL PAR LE FABRICANT,
THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE WOLF STEEL VENT KITS, SEE PRODUIT DECORATIF. NE PAS UTILISER COMME APPAREIL DE CHAUFFAGE
OWNER'S INSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLATION AND CLASS: 115V, 1 5AMP, WHZ
RESEALING IS NECESSARY AFTER SERVICING THE VENT -AIR INTAKE SYSTEM. L APPAREIL DOR EVACUER SES GAZ EN UTILISANT L'ENSEMBLE 0 EVACUATION PROPRE A WOLF STEEL. REFERER
WARNING: FOR INSTALLATION INTO A VENTED NON CC MBUST18LE FIREPLACE ONLY THE AU MANUEL O'INSTALLATION DE PROPRIETAME POUR L'EVACUATION PRECISE. IL EST IMPORTANT DE BIEN
MINIMUM FIREPLACE SIZE IS: HEIGHT 24 DEPTH 17'. WIDTH 34. THE MINIMUM INSIDE REINSTALLER ET RESCELLER L'EVENT APRES AVOR ASSURE LE MAINTIEN DU SYSTEME DE PRISE D'AR.
FLUE SIZE IS 6'. THE MINIMUM DISTANCE FROM THE BOTTOM OF A COMBUSTIBLE MANTEL ATTENTION: POUR INSTALLATION DANS UN FOYER VENTILE EN MACONNERIE. LES DIMENSIONS MINIMUMS SONT:
PROJECTING A MAXIMUM 3' FROM THE WALL TO THE TOP CF THE UNIT IS 12', SEE OWNERS HAUTER 24'G', PROFONDEUR 17', LARGEUR 34'. LE DIAMETRE INTERIEUR MINIMUM DE CONDUIT D'EVACUATION
MANUAL FOR GREATER EXTENSIONS. EST DE 6'. LA DISTANCE MINIMALE, DU BAS DU MANTEAU COMBUSTIBLE FORMANT UNE PROJECTION MAXMAL.E D
OPTIONAL FAN KIT- GZ550-KT. GOBS. T DU MUR AU DESSUS DE LA GARNITURE NORMALE EST 12'. REFERER AU MANUEL D'INSTALLATION POUR DES
EXTENSIONS PLUS GRANDES.
WOLF STEEL LTD. SOUFFLERIE OPTIONELIE GZW-KT, GD65.
24 NAPOLEON ROAD, BARRIE. ONTARIO 1_4M OG8 CANADA SERIAL NUMBER/NO. DE SERIE: w3a5-0s6z/D
INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to
the model, venting and gas type of the appliance.
For rating plate location, see "INSTALLATION OVERVIEW" section.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
NOTE: The rating plate must remain with the appliance at all times. It must not be removed.
W415 -1194/A/ 12.19.13
•
1
3.0 INSTALLATION
AWARNING
RISK OF FIRE, MAINTAIN SPECIFIED AIR SPACE CLEARANCES TO VENT PIPE AND APPLIANCE.
Clean out ashes from the inside of the wood -burning appliance. Make sure that the chimney and wood -burning
appliance are in a clean and sound condition and constructed of non-combustible materials. If necessary have
any repair work done by a qualified person before installing the insert. Remove the existing appliance damper
or lock into an open position.
Using screws, attach the appliance warning tag
to the inside of the firebox of the appliance into
which the insert is being installed.
The sheet -metal parts of the appliance, in which
the gas appliance insert is to be installed, must
not be cut.
/WARNING: THIS FIREPLACE HAS BEEN CONVERTED FOR USE WITH A GAS FIREPLACE\
INSERT ONLY AND CANNOT BE USED FOR BURNING WOOD OR SOLID FUELS UNLESS ALL ORIGINAL
PARTS HAVE BEEN REPLACED AND THE FIREPLACE IS RE -APPROVED BY THE AUTHORITY HAVING
JURISDICTION.
ATTENTION: CE FOYER A ETE CONVERTI AFIN D'ETRE UTILISE SEULEMENT
O COMME FOYER ENCASTRE AU GAZ ET NE PEUT ETRE UTILSE POUR BRULER DU BOIS OU O
TOUT AUTRE COMBUSTIBLE SOLIDE, SANS OUE TOUTES LES PIECES ORIGINALES AIENT
ETE REMPLACEES ET OUE LE FOYER SOIT APPROUVE DE NOUVEAU PAR LES AUTORITES
AYANT JURIDICTION..
ADVERTENCIA: ESTA CHIMENEA SE REMODEL6 PARA USARSE SOLO CON UNA
INSERCI6N DE CHIMENEAA GAS Y NO PUEDE USARSE PARA OUEMAR MADERA NI COMBUSTIBLES
S6LIDOS, A MENOS OUE SE HAYAN REEMPLAZADO TODAS LAS PIEZAS ORIGINALES, Y LAAUTORI-
\AD JURISDICCIONAL LA HAYA VUELTO AAPROBAR. ��,� a/
If the wood -burning factory -built appliance has
no gas access hole(s) provided, an access hole of 1'/2 inch (38.1 mm) or less may be drilled through the lower
sides or bottom of the appliance in a proper workman like manner. This access hole must be plugged with non-
combustible insulation after the gas supply line has been installed.
Ensure that existing chimney cleanouts fit properly.
The refractory, glass doors, screen rails, screen mesh and log grates may be removed from the existing
appliance before installing the gas appliance insert.
Smoke shelves, shields and baffles may be removed if attached by mechanical fasteners.
The ventilation openings in the existing appliance may be obstructed by the backer plates, aluminium trim etc.
but these parts are not to be applied so as to have an airtight seal.
68AB
f, 3.1 LEVELLING THE APPLIANCE
Move the appliance close to its final position. This appliance is equipped with levelling screws located on the
base. Level using the levelling screws. Levelling the appliance will eliminate rocking or excessive noise when
the fan is in operation. Once the appliance is level, move it partially into place to allow for all connections to be
made. It is not practical to level the appliance once it has been installed. Determine the required depth prior to
installing the appliance and adjust the levelling screws accordingly.
67.2
W415-1194/ A/ 12.19.13
A
3.2 CHIMNEY CONNECTION
Chimney installation must conform to both national and local code requirements. The chimney must be lined
with one 3" (76mm) diameter liner for intake and one 3" (76mm) diameter liner for exhaust. The minimum and
maximum vent lengths are 10 feet (3m) and 35 feet (11 m) respectively.
Recommended kits come in 3 lengths:
2-3" DOUBLE PLY ALUMINUM LINER -INLET AND EXHAUST.
GDI-320KT VENT KIT 20FT (6m)
GDI-325KT VENT KIT 25 FT (7m)
GDI-335KT VENT KIT 35 FT (11 m)
While the liners must be continuous from the appliance to the chimney cap, to
achieve the needed length, they may be coupled, using an approved coupler
and sealant.
We recommend that exhaust vents that pass through unheated spaces,
such as tall exterior chimneys, be wrapped in a protective sleeve to minimize
condensation and reverse flow symptoms. See Trouble Shooting for details.
This appliance is approved for use with a 3" (76mm) exhaust and air intake.
A
B.
EXHAUST
OUTSIDE: Slip the one end of a liner a minimum of 2" (51 mm) over INTAKE
the sleeve of the air terminal. Secure using 3 screws. Then seal the
joint and screw heads with high temperature sealant. Repeat with the other liner.
FLASHING
PLATE
2" (50.8mm)
OVERLAP
ILL -PAC
NOTE: We recommend that the other end of the exhaust liner be marked to eliminate the
exhaust liner being connected to the intake collar at the appliance.
Gently stretch the liners to the 3" (76.2mm)
required lengths and insert into LINERS
the chimney. Trim and fit the '
flashing plate to suit the chimney
termination. Place the air terminal
onto the top of the chimney.
Make weather tight by sealing
with caulking (not supplied).
Fasten to the chimney with
screws and plugs (not supplied).
C. INSIDE: Remove the securing
screw from the front of the vent
mounting plate. Pull the vent
mounting plate only, back into
the track, to the front stop. Start
the slider back into position. Re -
secure the screw. The appliance
may now be pushed into its
final position inside the wood
burning appliance, and the screw
tightened until the slider has
been pulled tight to the front stop.
HIGH TEMF
SEALANT
MOUNTING
2" (50.8mm) PLATE
OVERLAP
VENT MOUNT
ASSEMBLY
SECURING
SCREW
D. Route the flex liners through 'qj�/
the slider. Attach and secure
the liners to the vent mounting plate using the same procedure as before, ensuring that the marked
exhaust liner is attached to the exhaust collar.
W415-1194/ A/ 12.19.13