HomeMy WebLinkAboutB14-0096 Blower Door Report �� INTENTION ARCHITECTURE 53 red barn
� edwards, CO 81632
(970) 306-6612
seth@intentionarchitecture.com
untentionarchiteckure.com
December 2, 2015
Mike Dantas
Slopeside Construction
2121 N Frontage Road W#206
Vail CO, 81657
CC: Martin Haeberle,Town of Vail Building Department
RE:Air Infiltration Tests-2744 and 2754 Snowberry Boulevard
Dear Mike,
Please find attached the results of the air infiltration tests performed on the aforementioned properties. The test
results show that the homes comply with the maximum air infiltration rates established by the 2012 International
Energy Conservation Code (IECC)for Climate Zone 6.
The scope of this test was to determine air infiltration in accordance with the requirements of the RESNET One
Point Airtightness Test, as specified in Chapter 8, section 802.5 of the RESNET Performance Testing Standards.
Building square footage was calculated using construction documents, and building volume calculated using on-
site measurements and area-weighted averaging calculations.
Sincerely yours,
��''�� �����
_� °�°�� ��
�� ;���� � � , - , y�
t I � �{
Seth Bossung ± ��� +� ����� � '
� � �{}7$�1
BPI Certification 5034550 �� '�� �,�
��� �����'.
�� ��.
iTEC - RESNET Test Report
Test Results
Corrected CFM50 1,563 CFM50
Accuracy Level Standard
Air Changes per Hour @ 50 Pa 1.73 ACH50
2012 IECC Infiltration Maximum 3 ACH50
Result PASS
Effective Leakage Area(ELA) 86.0 Sq. in.
Test Date 11/17/2015
Building Information
Snowberry Duplex-WEST SIDE
2754 Snowberry Boulevard
Vail CO 81657
Year Constructed 2015
Volume 54,127.0 CuFt
Floor Area 4,587 SqFt
Building Height 30.1 Ft.
Test Readings
Nominal Building Pressure -49.8 Pa
Nominal Fan Flow 1,605 CFM
Nominal Fan Pressure 79.5 Pa
Fan Configuration Ring A
Fan Model Model 3 110V
Fan Serial Number 13876
Pressure Gauge Model DG-700
Pressure Gauge Serial Number 9253-6-700
Inside Temperature 71.0 F
Outside Temperature 30.5 F
Time Averaging Period 10.0 Secs
Baseline Readings
Average Baseline -0.4 Pa
Baseline Range 2.0 Pa
Location Information
Geo Tag Location
Longitude: -106.42747
Latitude:39.61693
Site Altitude 8,112.0 Ft
Page 2
iTEC - RESNET Test Report
Test Results
Corrected CFM50 1,572 CFM50
Accuracy Level Standard
Air Changes per Hour @ 50 Pa 1.79 ACH50
2012 IECC Infiltration Maximum 3 ACH50
Result PASS
Effective Leakage Area(ELA) 86.4 Sq. in.
Test Date 11/17/2015
Building Information
Snowberry Duplex- EAST SIDE
2754 Snowberry Boulevard
Vail CO 81657
Year Constructed 2015
Volume 52,596 CuFt
Floor Area 4,383 SqFt
Building Height 30.2 Ft.
Test Readings
Nominal Building Pressure -50.7 Pa
Nominal Fan Flow 1,626 CFM
Nominal Fan Pressure 81.6 Pa
Fan Configuration Ring A
Fan Model Model 3 110V
Fan Serial Number 13876
Pressure Gauge Model DG-700
Pressure Gauge Serial Number 9253-6-700
Inside Temperature 72.0 F
Outside Temperature 30.5 F
Time Averaging Period 10.0 Secs
Baseline Readings
Average Baseline -0.4 Pa
Baseline Range 1.4 Pa
Location Information
Geo Tag Location
Longitude: -106.42747
Latitude:39.61693
Site Altitude 8,112.0 Ft
Page 3