Loading...
HomeMy WebLinkAboutB14-0096 Blower Door Report �� INTENTION ARCHITECTURE 53 red barn � edwards, CO 81632 (970) 306-6612 seth@intentionarchitecture.com untentionarchiteckure.com December 2, 2015 Mike Dantas Slopeside Construction 2121 N Frontage Road W#206 Vail CO, 81657 CC: Martin Haeberle,Town of Vail Building Department RE:Air Infiltration Tests-2744 and 2754 Snowberry Boulevard Dear Mike, Please find attached the results of the air infiltration tests performed on the aforementioned properties. The test results show that the homes comply with the maximum air infiltration rates established by the 2012 International Energy Conservation Code (IECC)for Climate Zone 6. The scope of this test was to determine air infiltration in accordance with the requirements of the RESNET One Point Airtightness Test, as specified in Chapter 8, section 802.5 of the RESNET Performance Testing Standards. Building square footage was calculated using construction documents, and building volume calculated using on- site measurements and area-weighted averaging calculations. Sincerely yours, ��''�� ����� _� °�°�� �� �� ;���� � � , - , y� t I � �{ Seth Bossung ± ��� +� ����� � ' � � �{}7$�1 BPI Certification 5034550 �� '�� �,� ��� �����'. �� ��. iTEC - RESNET Test Report Test Results Corrected CFM50 1,563 CFM50 Accuracy Level Standard Air Changes per Hour @ 50 Pa 1.73 ACH50 2012 IECC Infiltration Maximum 3 ACH50 Result PASS Effective Leakage Area(ELA) 86.0 Sq. in. Test Date 11/17/2015 Building Information Snowberry Duplex-WEST SIDE 2754 Snowberry Boulevard Vail CO 81657 Year Constructed 2015 Volume 54,127.0 CuFt Floor Area 4,587 SqFt Building Height 30.1 Ft. Test Readings Nominal Building Pressure -49.8 Pa Nominal Fan Flow 1,605 CFM Nominal Fan Pressure 79.5 Pa Fan Configuration Ring A Fan Model Model 3 110V Fan Serial Number 13876 Pressure Gauge Model DG-700 Pressure Gauge Serial Number 9253-6-700 Inside Temperature 71.0 F Outside Temperature 30.5 F Time Averaging Period 10.0 Secs Baseline Readings Average Baseline -0.4 Pa Baseline Range 2.0 Pa Location Information Geo Tag Location Longitude: -106.42747 Latitude:39.61693 Site Altitude 8,112.0 Ft Page 2 iTEC - RESNET Test Report Test Results Corrected CFM50 1,572 CFM50 Accuracy Level Standard Air Changes per Hour @ 50 Pa 1.79 ACH50 2012 IECC Infiltration Maximum 3 ACH50 Result PASS Effective Leakage Area(ELA) 86.4 Sq. in. Test Date 11/17/2015 Building Information Snowberry Duplex- EAST SIDE 2754 Snowberry Boulevard Vail CO 81657 Year Constructed 2015 Volume 52,596 CuFt Floor Area 4,383 SqFt Building Height 30.2 Ft. Test Readings Nominal Building Pressure -50.7 Pa Nominal Fan Flow 1,626 CFM Nominal Fan Pressure 81.6 Pa Fan Configuration Ring A Fan Model Model 3 110V Fan Serial Number 13876 Pressure Gauge Model DG-700 Pressure Gauge Serial Number 9253-6-700 Inside Temperature 72.0 F Outside Temperature 30.5 F Time Averaging Period 10.0 Secs Baseline Readings Average Baseline -0.4 Pa Baseline Range 1.4 Pa Location Information Geo Tag Location Longitude: -106.42747 Latitude:39.61693 Site Altitude 8,112.0 Ft Page 3