Loading...
HomeMy WebLinkAboutE16-0001 . ` /` . �`. \� - — --- --- 01-13-2016 Inspection Request Re orting Page 21 --- --_--- -- _------- -4_�4-p nL -_ - ----- -- V i�; C0 -_ ' _----- Requested Inspect Date: Thursday,January 14 2016 Site Address: 2475 GARMISH DR VdIL Sunlight Unit 5 A/P/D Information Activity: E16-0001 Type: B-ELEC Sub Type: AMF Status: ISSUED Const Type: Occupanc : Use: Insp Area: Owner: JOHNSON, ERIC S.-LINDSTR�M,CHERYL G Applicant: MD MOLLER COMPANY Phone: 970-376-8785 Contractor: MD MOLLER COMPANY Phone: 970-376-8785 Description: Tie in PV to grid power. Bring Electrical panel u�p to code for Solar PV Roof Panels Comment: paper submiftal routed to lasertiche and C-4-CGODFREY Comment: see 615-0410 PV Fee has already been paid per state requirements.-CGODFREY Reauested Insaection(s) Item: 120 ELEC-Rough Requested Time: 11:30 AM Requestor: MD MOLLER COMPANY Phone: 970-376-8785 Comments: 390-3345 Assigned To: SG Entered By: JMONDRAGON K Action: Time Exp: Item: 190 ELEC-Final Requested Time: 12:00 PM Requestor: MD MOLLER COMPANY Phone: 970-376-8785 Comments: 390-3345 Assigned To: SGREMMER Entered By: JMONDRAGON K Action: Time Exp: __ � Inspection Historv :� � �� Item: 120 ELEC-Rough � Item: 190 ELEC-Finar REPT131 Run Id: 15030 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ,. �a�ra�v�; . Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 ELECTRICAL PERMIT Permit #: E16-0001 Project #: PRJ15-0579 Job Address: 2475 GARMISH DR VAIL Applied.....: 01/05/2016 Location......: Sunlight Unit 5 Issued. . . : 01/07/2016 Parcel No....: 210311414005 OWNER JOHNSON, ERIC S. - LINDSTROM 01/05/2016 PO BOX 2088 EDWARDS CO 81632 APPLICANT MD MOLLER COMPANY 01/05/2016 Phone: 970-376-8785 MICHAEL MOLLER PO BOX 2153 ' AVON CO 81620 License: C000003393 CONTRACTOR MD MOLLER COMPANY 01/05/2016 Phone: 970-376-8785 MICHAEL MOLLER PO BOX 2153 � AVON CO 81620 License: C000003393 Description: Tie in PV to grid power. Bring Electrical panel up to code for Solar PV Roof Panels Valuation: $2,500.00 Square Ft: 100 ,.,...............................................<,............,.....,......,.... FEE SUMMARY ........,,,,...............,....,.,,..,.....,,,,......,.........,,.............., Electrical Permit-----------------> $57.50 Investigation-----------------------> $0.00 � TOTAL PERMIT FEES--------------> $0.00 Payments-------------------------------> $0.00 BALANCE DUE------------------------> $0.00 ...............................................................................«.............«,........_......,......,.«...,,......................,..,,....,w..,...,.,.«..,..«........ DECLARATIONS I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM -4:00 PM. electrical permit_102615 � � - �t ��L1� !'!�L j ....................................................................................................«..«..............,..,...........,.,..,..,.............,......................... CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAI, SIGN OFF Permit#: E16-0001 Address: 2475 GARMISH DR VAIL Owner: JOHNSON, ERIC S. - LINDSTROM, CHERYL G Location: Sunlight Unit 5 ..................................................................................................................................................................................... Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. efectrical permit_102615 � � x � �Oi�N QF YA� ' ***.***..�*****.***.*********.x**********.**********************************.************,********w*..*********.**********�*****„*.***,.**.,***�.****** REQUIRED INSPECTIONS AND STATUSES 1 Permit#: E16-0001 Address: 2475 GARMISH DR VAIL Owner: JOHNSON, ERIC S. - LINDSTROM, CHERYL G Location: Sunlight Unit 5 *,,.*,..***«************************�***„***«.,«,,,,********«***«,,,.«,..*****„*********«*„*,.,.****«***,,,.*********************,.*********,,,.**************«*«,,.* Item: 00120 ELEC-Rough Item: 00190 ELEC-Final electrical permit_102615 � . �,� ' Department of Community Development �� 75 South Frontage RoadWest TOWN OF VAf L '� `" � va�i, CO 81657 _-__.___._______. _ __ _. Tel: 970-479-2139 www.vailgov.com SOLAR THERMAL/SOLAR ELECTRIC PERMIT APPLICATION (Separate applications are required for any electrical work or any roof alteration) Project Street Address: - --- .,.� -,�- / � Project#: ��.J � 5 ° �S'i `�'� --• i � t;c��r.����'� (Number) (Street) (Suite#) DRB#: �i.���J — �� I O Building/Complex Name: .J L^^�� ���T �G`�� • Permit#: �•I C� ` �'G'C.'' � Project Information: Lot#��Block#� Subdivision: �(�{���c�C,�?�t,� Owner Name: �c- � ; J nh�, � n,, �. 1� �G�, , Parcel# �'-� `�, 1 1 �1 i '`1 �%i�� ____ __ ____ ___ ___ (For Parcel#,contact Eagle County Assessors Office at(970)328-8640 or visit Work Class: New�� Addition ( ) Alteration ( � www.eagiecounty.us/patie) � Contractor Information Type of Building: ��I, Single-Family( ) Duplex( ) Multi-Family�) Business Name: �`�1 �1.3, �`�e('v� �:� . Commercial ( ) Other( ) Business Address: �� �c��{ 2 V �� ' City �•.f::>�, State: �'_<� Zip: �;r <_:? Work Type Interior � ( ) Exterior( ) Both�) � Contact Name: _ �''i i�,� M ��l�� — — _ Contact Phone: ���1 c� • � ' ���, . �j�$� Solar Application Type: , Contact E-Mail: ,Mi � k�_����;Q �. �:�I ,�� r��f.� Residential (xj Non-Residential O � _. � __._. I hereby acknowledge that I have read this application,filled out in full the ' Solar Type: f information required,completed an accurate plot plan, and state that all i the information as required is correct. I agree to comply with the infor- Solar Electric�) Solar Thermal O � mation and plot plan,to comply with all Town ordinances and state laws, i and to build this structure according to the town's zoning and subdivision I codes, design review approved,International Building and Residential Codes and other ordinances of the Town applicable thereto. ^ � Value of all work being performed: $ ��S�O � ` (value based on IBC Section 109.3&IRC Section 108.3� ��--`�_ � Owner/Owner' resentative Signature(Required) , Detailed Scope and Location of Work: � Applicant Information � ���;r,�- ;,r, ��P r� r��� � ����p�. � .� Applicant Name: � ' � ��"r�� � c� �,Jz� •��, � s � i -ir.ci.r � ��k' ` �- j r C c"� . Applicant Phone: Applicant E-Mail: i i Additional Authorized ProjectDox Users i Full Name: i (use additional sheet if necessary) j ! E-Mail: Date Received: Full Name: E-Mail: i r � � r (use additional sheet if necessary) �� � � � � ��,� �,-�, � ��� _ � I ;I �;�_ For Office Use Only: J�{il �v z[�}'� ! Fee Paid: I Received From: � I -��;�,���, �� �,�.I L Cash Check # �-��- � � CC: Visa / MC Last 4 CC # Auth # 2015-Dec Ac��i�rv�� ELvN��zc=i�� �oi�.��z.,.r.�� Solar instailation lnformation Vendor: ActiveEnergies SolarLLC .; ;��i� PO Box 7627 ;����,���D F�� C��� Avon, C4 81620 (970-3Q6-4233/info@activeenergies.com) r���� � �`���� Site: Johnson Residence ~` " /- � � .. _: _�-�� __:.,��. Sunlight North Condominiums 2475 Garmisch Drive#5 °�- �` -�-'--�"` Vail, CO 81657 � ���� �;��' _ �_.���.� System Layout: Single Pane1=5.38ft tall X 3.2$ft wide System Size=13.52ft tall X 16.i8ft wide(including mounting equipment) Panel Arrangement:2 columns of 5 panels oriented in the landscape position,mounted flush on the southeast facing roof ---- , � , � PV disconnect& �"������ >;��� �°Y �� inverter ,� �, �- .y�.. � � �. �_...,�. �:. � �I a��_� � �� � ,� �. .„�. r r � ���� � ���;`��" ��" ��`� r� �f,, � t � rz� � ,"..�" #y � f` �''�. . Holy Cross meter �-'�� ' � �� � ��: Equipment: Panels: 10 LG315N1C-G4 @ 315 watts Inverter: 10 SolarEdge P320 optimizers+1 SolarEdge SE3000A-US inverter Mounting Equipment:Unirac racking system with Easy Feet Monitoring: SolarEdge Remote Energy Monitoring System Holy Cross electric meter located on in the southwest side of the condo complex. The PV disconnect and inverter to be located on the northwest side(back)of the individual unit. Meter placard required for Holy Cross. Minimum Designed Temperature: -40°F M�imum Ambient Design Temperature: 140°F All AC wiring to be completed by a Colarado licensed rnaster electrician All DC wiring to be overseen by NABCEP certified installer Pa e 1 of 4 10/13/2015 P.O.Box�627,Avon,CO 81620 � P: 970.306.4233 � F: 8b6.403.3485 � www.activeenergies.com At+�PTV�+i ENN��z(�IN:S �OL�1�2.r.,.<� Calculations 3.15kW System Size (STC) • 10 LG315N1C-G3 solar modules @ 315watts • 10 SolarEdge P320 Optimizers • 1 SolarEdge SE3000A-US inverter(1 string of 10 modules/oprimizers} • Fixed anay tilt angle: 18.43° • Array azimuth: 105°(where 180°is south) • Estimated annual power production: 4,068kWh Maximum PV System Voltage: 690.7 Voc=40.6V/module 40.6V x 1 module=40.6V Temperature correction factor 690.7(A) STC=25°C, Temperature Coefficient(Voc) _-0.28 %/°C (-40°C -25°C}=65°C 40.6V+(-65°C x(-0.28%/°C x 40.6V)x 1 module)=48V Maximum PV Source Circuit(String} Current: 690.8 (A)(1) Igo= 10.Q2A 10.02A x 1.25 = 12.SA Maximum PV Output Circuit(Array) Current: 690.8 (A)(2) 3,150w/350v=9A per 10 string SE3000A-US inverter limit 9.SA combined string Inverter Output Circuit Current: 690.8 (A)(3) 12.SA @ 240V John Wiles, "Photovoltaic Power Systems and the National Electrical Code: Suggested Practices", 2005,pp. E1-E25. pdf version online at: httn://www.nmsu.edu/%7Etdi/Photovoltaics/Codes- Stds/PVnecSu�Pract.html M Page 2 of 4 10/13/2015 P.O.Box 7627,Avon,CO 81620 � P: 970.306.4233 � F: 866.403.3485 ( www.activeenergies.com A.C"PIVE Eiv��:�zC�i�:s SOI.�'�12.�.,.� Conductor Sizing Pass Thru Box from Optimizers to Inverter(per combined string}: SE3000A-US inverter limit 12.SA combined string 9.SA x 1.25 = 11.9A #10 THWN-2 Table 310.16 40A (90°C column, see note 240.4(D)) Conduit fill adjustment Table 310.15 (B)(3)(a) No conduit fill adjustment Temperature conecrion factor Table 310.15 (B)(2)(b) 40Ax .77=30.$A Inverter to Disconnect to Service Panel: Nameplate maximum continuous output current: 12.SA @ 240V 12.SA x 125%= 15.6A 210.19 (A)(1) #10 THWN-2 Table 310.16 30A (75°C column) No temperature conection factor No conduit fill adjustment Overcurrent Protection Device 20A two pole breaker Per Manufacturer Specificatian Conductors may be oversized for voltage drop Page 3 of 4 10/13/2015 P.O.Box 7627,Avon,CO 81620 � P: 970306.4233 � F: 866.403.3485 � www.activeenergies.com Array mounted on roof 10 LG315N1C-G4 Solar Panels 2#10 USE-2lRHW-2 10 SolarEdge P320 DC Optimizers 1#6G Bare Cu Conductors in Free Air I___'_____.'___1 1 2 1 ... 10 i- --- Pass-Thru i Box --- ---- --- ------- Located on roof +/-100� '/."C EMT/LFMC 2#10 THWN-2 t#10 G THWN-2 i � � i i �------- --- �i '------------------ fnverter w/ Integrated DC Disconnect SolarEdge SE3000A-US NEMA 3R Max AC Output:12.5A @ 240V Located badc of unit Line Dia rg am Johnson Residence Sunlight North Condominiums 2475 Garmisch Drive#5 Vail,CO 81657 Placard on meter stating "Phomvoltaic System Connected" And location of PV Disconnect per Holy Cross specifications Net Meter Q On south side of home +/-3' +/ 0' C EMT/PVC/LFMC '/."C EMT/PVC/LFMC/NM-B 3#10 THWN-2 3#10 THWN-2 1#12 G THWN-2 1#12 G THWN-2 30A � Disconnect Located back of unit ------- ------- - • . r, : ^ . � DC Grounding • n Electrode Conductor � ^ solid bare#6 Cu per NEC 250.66(C) � � n n � � Service Panel Located in home Backfeed Breaker 20A 2P 240V Ac ��r1�-� E�TL+,1-�c�IN�� �1.11.J1�1\,LLC 3.15 kW Utility interactive Photovoltaic System Pa e4of4 P.O.Box 7b27,Avon,CO 81620 � P: 970.306.4233 � F: 866.403.3485 � www.activeenergies.com Modules: 10 LG315N1C-G4 Voc=40.6V Isc= 10.02 A Optimizers: 10 SolarEdge P320 1 String X 10 Modules Inverter:SolarEdge SE3000A-US Operating Voltage: 350V Operating Current: 9.5A Max System Voltage:500V Max Output Current: 15A Tilt Angle: 18.43° Array Azimuth: 105° Production:4,068kWh, -See Calcu/ation Sheetfor conductor sizing. -All conductors are copper unless othervvise noted. -Inverter listed(UL-1741)to de- energize upon loss of utility voltage per NEC 690.61. -Inverter has integral ground-fault protection per NEC 690.5 -240V 1 Phase Service Panel rating of 100A(bus rating 100 amp and 100 Main disconnect)to accommodate 20A+ 100A= 120A supply(up to 120%of connected power sources from residential installations per NEC 690.64(B)(2)) � � �.����� ` `z da;E" ;G. � �+' �' ��� a `s^ �3 3i � � � �� � � � � � � !� P� F; � � � • � � 1 / ' ,�..,r� 1 �� . The new Q.PRO BFR-G4 is the result of the continued evolution of our -- Q.PRO family. Thanks to improved power yield, excellent reliability, and �.�� high-level operatianal safety,the new Q.PR� �fR-�4 generates electricity at a low cost (LCOE) and is suitable for a wide range of applications. � LOW ELECTRICITY GENERATION COSTS �" Higher yield per surface area and lower BOS costs thanks to higher power classes and an efficiency rate of up to 16.2%. � INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low-light and temperature behavior. �, ENDURING HIGH PERFORMANCE ��' Long-term yield security with Anti-PID Technology�, Hot-Spot-Protect and Traceable Quality Tra.QT^". � LIGHT-WEIGHT QUALITY FRAME High-tech aluminum alloy frame,certified for Q�� high snow(5400 Pa) and wind loads(4000 Pa). roaewwow '"�°:"°"'� �� MAXIMUM COST REDUCTIONS 2014 Up to 10% lower logistics costs due to higher module capacity per box. SAFE ELECTRONICS PhnlnrY Protection against short circuits and thermally induced power losses � Quallty Tested Q�LS � due to breathable junction box and welded cables. ,„�,�„�,,,Ty �,�,��e,,;� �1tl"tl°e'etl°9O' fdarmodub2013 i�rewsm .. . QPR0.C2 R76 O A RELIABLE INVESTMENT IDtl400325&; "'•°�'"" Inclusive 12-year product warranty and 25-year linear performance guaranteez. � nPT test conditions:Ceiis at-i000v against grounded,with conductive me- tal foil covered module surface,25°C, THE IDEAL SOLUTION FOR: 168n z See data sheet on rear for further �Rooftop arrays on �Rooftop arrays on Ground-mourted infORnOtion. residential huildings commerciaf/industrial wlar power plants buildings Engineered in Germany Q CE`,`,S I � Format 65.7 in x 39.4 in x 1.26in(including frame) "P;;° ��c�.,o.� (1670 mm x 1000 mm x 32 mm) """°�'-' WeIgM 41.45 Ib(18.8 k� 1 YYGn�IItpMm�O.l�µ5w) # FroM Cover 0.13 in(3.2 mm)thermaly pr�shessed glass with anti-reflection technolo�r o-,�„�,,,,,, �... ar.«�io�.0 ack Cover Composite film ym„�W I Frame Btack anodized aluminum } +aM1++ „�.,,,m.., Cell 6 x 10 polycrystalline solar cells '""�'1W` � �' lunction 6ox 4.33 in x 4.53 in x 0.9 in(110 mm x 115 mm x 23 mm), Protection class IP67,with bypass diodes } ,,,,,�o„��,�N ..■�w.}n.. Cable 4 mmY Solar cable;(+)x39.37 in(1000 mm),(-)¢39.37 in(1000 mm) � ��t.lf(.G W 0[iYIA ObAf (�B�1 Cannector Tyco Solarlok PV4,IP68 0�,���I�Ioaans�� POWER CLASS 255 260 265 MINIMUM PERFORMANCE AT STANDARQ TEST CONDITIONS,STC'(POWER TOLERANCE+5!N 1-Q W) Pawer at MPP� P„�, (W] 255 260 265 Short Circuit CurreM` ke [Al 9.07 9.15 9.23 e E Open Circuit Valtage* V,� [1q 37.54 37.77 38.01 � Current at MPP• Ip„ [A] 8.45 8.53 8.62 Voltage at MPP` V„� M 30.18 30.46 30.75 EHiciencyT q [%l t 15.3 a 15.6 t 15.9 MINIMUM PERPORMANCE AT NORMAL OPERdTING CONDITIONS,NOC3 Power at MPPz PNPP [W] 188.3 192.0 195.7 � Short Circuit CurreM` I� W 7.31 7.38 7.44 � Open Circuit Voltage` V,� [V] 34.95 35.16 35.38 .:_ � Current at MPP* i,�P [IU 6.61 6.68 6.75 Voltage at MPP' V� [V] 28.48 28.75 29.01 '1000 W/m',25°C,spectrum AM 1.5G �Measu2menttolerences STC m3%;NOC i5% '800 W/m�,NOCT,spectrum AM 1.5G 'rypical values,actual values maydiffer Q CELLS PERFORMANCE WARRANTY PERfORMANCE AT LOW IRRADIANCE ,.��m �or�un o�^�---T--r--T--i i i i -i--� . . �� At least 97%ot nominal power during � , � � � � i , W s, ,�„Y�e.e,���M...�.�u., � � �� u3 � �o,..n,�man,n.c.�.�.�n.: firstye�.Thereaftammr.0.6%degra- � �w---�--�- -'--'���-�+"�'t '� -------------------------- -- W d dation per yeac W , i ; ; ; ; ; i , >� Atleast92%ofnominalpowerafter � p --�--`-�--'--'--�--�--�--; i � i i i i i i i � 10 W i � � � � � � i W f ------------- Y�rs• �° Atleast83%ofnominal erafter � °0'--r--r--r-r--,---,--�--,--� P�'/ ❑ i i i i i i i i �::a •., - - 25 y�rs. � �--� � � � � � � � � � . ,,.� � r--r- r--r--i--r-r-�--� � � i � i i � i ' All data within measurement tolerances. �'�ee sno aoo .00 me .00 ioo m �oa iwe '� Full warranties in accordance with the oa ' warranry terms ot the Q CELLS sales IRRADIMICE[W/m'] „r---,.__�_.__T__._-----? or anisation of g your respecti�country. ` ` The typical change in module efficierwy ffi an irr�iance of 200 W/m4 in relation "°^'^°^� �=�q � =a��m�v���a, to 1000 W/m�(both at 25°C and AM 1.5G spectrum)is-2%(relative). z N TEMPERATURE COEFPICIENTS � Temperature Caefficient of Isc a [%!K7 +0.04 Tennperature Coefficient of Va Q � [%/K] -0.30 �, Temperature Coefficient of P„PP Y [%/K] -0.41 Narmal Operating Cell Temperature NOCT [°C] 113 t 5.4(45 t 3°C) � � � .�. �. � m 0 Maximum System Volbge Vs„s M 1000(IEC)/1000(UL) Safety Class �� a 0 Maximum Series Fuse Rating [p pC] 20 Pire Rating C/TYPE 1 E Ma�c Luad(UL)� p6s/ft�J 75(3600 Pa) Permitted madule temperature -40°F up to+185°F � on continuous duty (-40°C up to+85°C) Load Rating(UUz pbs/it'] 55.6{2666 Pa) 2 see installation manual � � : 0 t � � 1 � I • � �, , �. , � � UL 1703;VDE Qualiry Tested;CE-compliant; Num6er of Modules per Pallet 32 ` IEC 61215(Ed.2);IEC 61730(Ed.l)application dass A ; Numher of Pallets per 53'Container 3p � DVE /' � !ee Number of Pallets per 40'Container p6 $ � ,�P Pallet Dimensions(L x W x H) 68.7 in x 45.0 in x 46.0 in �. ♦ ���;��US „�,,.,, (1745 x 1145 x 1170 mm) � Pallet Weight 1323 Ib(651 kg) � NOIE:Installation instructians must be followed.See the installation and operating manual or contact our technical service department for fuRher information on approved installation and use � of this product. N He�a c��s usn c�. 300 Spectrum Center Drive,Suite 1250,Irvine,CA 92618,USA I TEL+1 949 748 59 96 I EMAIL q-cells-usa�qcells.com I WEB www.q-cells.us Engineered in Germany Q C,E`,`S � • solar - • • � SolarEdge Power Optimizer Module Add-On For North America P3�0 / P320 / P400 / P405 � ,.x.._ � ' �./�,r�''f��xr� ��. � ��'Y x f&r;� ; �,,�,��'f r� ...:,a� £ �,z:;^ �'w�+j +M�� Nre�+�.. �.���,r �r,�� r�d ��.i t •-'�� 4` ,.t�m�"'` .:t.�� %a�},`�3 J�;� � � ��� i; . q 1� � - � � . � � . .� . � .. :�'�� .s� � . . . .. . .. . . .�. . . ��. . . . .. ..3. e� ��'�� �QOWCI p G . . � . . . . hQ'` �e� �� a 25Vear5 ; s; ��arra��� -� �,o o," °'•�az�Wn ��+�� . .. . . . . . . .... . . r . . � . . � � :b' .. � . . . .. - . . . � :S: � ��.-��.. . . . k - �' �' <a �: �f.':' : . � . . . . . . . t �I PV power optimization at the module-level t � Up to 25% more energy F Superior efficiency(99.5%) � Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading ����_ �� Flexible system design for maximum space ufilizatio� � Fast installation with a single bolt � Next generation maintenance with rnodule-level monitoring � Madule-level voltage shutdown for installer and firefighter safety USA - GERMANY - ITAIY - FRANCE - JAPAN - CHINA - ISRAEI - AUSTRALIA www.solaredge.us I so I a r - • • � SolarEdge Power Optimizer Module Add-On for North America P300 / P320 / P400 / P405 _�__._�__ __._ _ ___. __ �_ _____ __ ___. i P300 � P320 P400 ' P405 i (for high-power (for 72&96-cell � tfor thin flim (for 60-cell modules) � 60-cell modules) � madules �p�.� modules�_�„� _... _ .�. _,____.__�_._.�.�_.�.�.._�._.__. _...._ INPUT� —• ______ .�__�__,.__�._�,.__�__.._.__.._._..._m._.._.,._____._..��__.__ Rated Input DC Power�l� .,. , ..a. ,.. 300.,. .. . ..� .. r y ,32D . .... �..,, 400 A05 W . .._....,, .. ................................................... .............. Absolute Maximum Input Voltage 48 80 125 Vdc ,(Voc at lowest temperature�. ......... .... e........ ....e......,..............._............-•--................................... ............... .MPPT Operatin&Ran�e 8 48 8-80 12.5-105 Vdc ..... ........................... ........................... ............................ ..............,... .............. Maximum,5hort Circuit Current(Isc).. 30 11 30 Adc ........................... ........................... ................................ Maximum DC In�ut Current............ ,,,,12:5 13.75 12.5 AdC ._...... ....... ........ . ............................ ....._........................ Maximum Effiaenc� . 99.5 %o ......... ........ . .......................................... _.............................,.......................... .....%...... .Wei�htedaEfficiency.. ...,u......... ... 98.8 ..�...................................................._......... ........._................. Overvolta e Cate or ...�'.. ............. .....�....�... .__.__�___.__.�_Y I I OUTPUT DURIN6 OPERATION POWER OPTlMIZER CONNECTED TO OPERATING 50LAREDGE INYERTER) � � � .Maximum Output Current 15 Adc� ...., ............... ....................................e..........._.......,......,..,...........a..�.,..�......,.,.............. ,............. Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR 50LAREDGE INVERTER OFF) Safety Output Voltage per Power�Y�`� � � vv 1 AR_- .�N y��' m �`�T Y Vdc O m¢er � -_�__.. ______.._s___�___._�__�� STANDARD COMPLIANCE --- —.-____ � EMC,,,,,,,,,,,,,,,, .FCC Part15 Ciass B,IEC61000-6-2,IEC61000-63 ........................ .................o.......,, .................................,...,..........................,..............,.,,......,........ ..SafetY...................................... ....................................IEC62109-1(class il safety)r UL1741........,...., RoHS i ..................... .............. Yes INSTALLATION SPECIPICATIONS � � Maximum Allowed System Volta�e 1Q00 Vdc . ............................ . . .... .........,...,....... ..............._.......,............,..............................,........_...,..........,.....,. .Compatib,le inverters .All SolarEdge Sin�le Phase and Three Phase inverters .....e.............. ....•••• ............................... .............. �........................ Dimensions jW x L x H) 128 x 152 x 27.5/ s 128 x 152 x 35/ 128 x 152 x 481 mm in .., .,a... ..... 5x5:97x.1.Q8 � 5x5.97x1.37.... .....Sx5.97x1.89 .......�..... .................................. ... ............. . .......,.........,.. ......,............. Wei ht mcludin cables 770%1.7 � 930/2.05 930 J 2.05 �r,(Ib ..�. .�.........�........)............. .•••....................................... .1.... ..e.,....................................... .... . .. .. ..,........ ...... .., .Input Connector MC4 Compatible._. . ........................................•••.....,........................ ..........._....... Output Wire Type/Connector..,. Double Insulated MC4 Com atible ... .... ................................................... P .........o........... .... ........... ........ Output Wire Length .e................ 0.95/3.0 1.2/3.9 m ft ....................................................•-va......_....._.........,.................................. .............. Operetin�Temperature,Ran�e,._ .. .. -40 +85/.-40 +185 C/°F ............................................... ............,......................................... .....,........ Protection Rating IP6$/NEMA6P ....... .......... .... .,...... ...._........................0-100......................._........................... .............. Relative Humidi . .....�.............tY._.......-•-•..,._...... % ....�......................_............_...........----� �'�RetedSfCpoweroftMmodule.Moduleofu W+5% ...............•.........-.....-•"'.......•..-•-'-•,... ....-......... p powartohranceallowed. . ...__. _.._------------_. _ __.._.. .__....--�-- ._ _._.___.... . __-__-.--__-__._�_-----'------- .. _._._----`------..__._. � PV SYSTEM DESIGN USING SINGLE PHASE THREE PHA5E 208V THREE PHASE 480Y A SOLAREDGE INVERTER� ___..__.___.._._..,.__.__.--_.__ ____._ _.� _. __._ _...____ ,_ Minimum String Length 8 10 � 18 .,(PowerOptimizers�.... .....p ....,... .............. ....................................................... .. ..,, ..,......,....... ,...................,.....,.......... Maximum String Length 25 25 50 (Power optimizers�........................................................... .. ..,....... . . . . . . ..................................... .............. .. ... ........... ... ....... ..... Maximum Power per Strin� . 5250 ......6000 12750 W ....................... ......,........................,.... ......... Yes ............... ......, ............... ....... Parallel Strings of Different Lengths or Orientations .............................................................................................................................................................. .............. n�R is not aDowed to miz P405 wtth P300/P400/PfiW/P700 in one string. .. I � o •� �: _ . • . solar - • • ! . SolarEdge Single Phase Inverters . For IVorth America SE3000A-US/ SE38QOA-US/ SE5QOOA-US 1 SE6000A-US 1 SE7600A-US/ SE10000A-US / SE1140QA-US .������{ki§�$:�ix3�i���r� �-+�s�;���'�� �:�.; �4�,:�r�.A i� �.4 a �e3 ,� � �. �;,,h s ?a�2,+�:�St :� �'. �" J � ia�s ,+�� �. xr. 6` 7+� �d,��''��.e�Y 7e�c- . t � r zsr. t *� ,��a'��� i��"�U�� d � "k �ms r�����'��y�.x��'`� .."�t,�sz�`�`a�.r,:, f�����rt�`��',���xra1�,�� � ��e'� :i��� � ��� � �" � � �� '���+�����'s�hk��� 't�my�"`� n�, ✓ � �.'� . � x �� a`t � � . . . .. � - � ���.���.��i�e F nVe�f� . `�����`�,��`�'�ur2'��rv��Or�t���, �� �' � � � . . .. . ' ; �� �� ��� �� .�12 25 '� a k� ��� a �� m s, ,����zx�� � �':�� ° ���� `',�«'�r��z���� ��1�(8[(��i � �; � �,� � ; ��8t,a���� _ ,. �; � � s �Z ��5p��P�������� �y✓ � ,���y'��z���4�`�e:'�`r"a�.� �9 t�l'RN�J:73������t .� �� '� „t�7 a��]'� � . . � �mi y°� . . SI !tL.�.. . . . 1f .. � ����� w as?ie ���.. � .. , .. . . . . ��.. � ��� �'. . ..... .. k ,....,'. ,. ..:..,� ,<n ._,.:,��-.. The best choice for SolarEd e enabled s stems � Integrated arc fault protection(Type 1}�for NEC 201169Q.11 compliance :� a= Superior efficiency(98�6} � - Small,lightweight and easy to install an provided bracket � �- Buiit-in module-fevel monitoring a� ,;� � Internet connection through Ethernet or Wireless � :� -� Outdoor and indoar instaliation F f � Fixed voltage inverter,DC/AC conversion oniy � Pre-assembled Safety Switch for faster installation � Optional—revenue grade data,ANSI C12.1 U�A GERMAN'Y {Tt�IY FRANCE: 1APAPJ CNINA-AUSTRALIA-THENEFHERLANRS-ISRAEI WWW.solaredge.us so I a r � • � S�ngle Phase Inverters for North America SE3000A-US/SE3800A-US/SE5DOOA-US 0 SE6000A-US/ SE7600A-US J SE10000A-US/SE11400A-US �T� � SE3000A-US SE3800A-US SESOOOA-US { SE6000A-U5w SE7600A-US SE10000A-US SE11A00A-US OUTPUT �� � � ----,-------- -� r-------r----______,..�__�---- Nominal AC Power Output � 3000 3800�� 5000 �� ��~' i 9980 @ 208V f ' 4 6000 76� � 10000 @240V 4 11400 � VA Max.AC Power Out ut 3300 4150 5400 @ 208V I � � 30800 @ 208V P � 5450�240V � 600Q ` 8350 � 10950�240V 12000 VA . s AC Output Voltage Min:Nom.-Max.�'� _ _ � � . � _ � � _ 183-208-229 Vac AC Output Voltage Min.-Nom:Max.�'� � � I � � � � � � � 211-240-264 Vac AC Frequency Min:Nom.-Max.�l� 5i9.3-60-60.5{with H I country setting 57-60-60.5) Hz Max.Conttnuous Output Current 12.5 I 16 I ZS�1 240V � ZS � �Z � 42 C�a 240V � 47.5 A . i GFDI 1 A Utilit r�Monitoring,Islanding Protection,Country Con�urable Thresholds Yes Yes INPUT `�C,mmended Max.DC Power{2� 3750 4750 � 6250 7500 9500 12400 14250 W Transformer-less,Ungrounded ! Yes Max.Input Voltage 500 Vdc Nom.DC Input Voltage 325�208V/350 @ 240V Vdc Max.Input CurrenN'� 9.5 I 13 � 15.5�240V � 18 � 23 I 30.5 @224 V � 34.5 Adc • I Max.Input Short Grcuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600kn Sensftivity . . . Maximum Inverter Efficiency 97.7 98.2 98.3 98.3 � 98 98 98 % CEC Weighted Efficiency 97,g � 98 97•5 @ 208V � 97.5 97S 97�2�� 97.5 % a � 98 @ 240V ( � 97.5 @ 240V � , � NiphttimePowerConsumption�� ; <2.5 ����� <4 W ADDITIONAL FEATURES Supported Communiwdon Interfaces R5485,R5232,Ethernet,ZigBee(optionai) Revenue Grade Data,ANSI C12.1 Optional�4� Rapid Shutdown-NEC 2014 690.12 �Functionality enabled when SolarEdge repid shutdown kit is installed�s� STANDARD COMPUANCE ��� ��~ � �� � Safety �� UL1741,UL1699B,UL1998,CSA 22.2 �� Grid Connection Standards IEEE1547 Emissions �� � � mqM� ��N FCC part15 class B INSTALLATION SPECIFICATIONS �� �� AC output conduit size/AWG renge 3/4"minimum/16-6 AWG ��w�� 3/4"minimum J 83 AWG DC input conduit size/#of strings/ 3J4"minimum/1-2 strings/16-6 AWG 3/4"minimum/1-2 strings/14-6 AWG AWG range , q Dimensions with Safety Switch 30.5 x 12.5 x 7/ 30.5 x 12.5 x 7.5/ in/ 30.5x12.5x10.5/775x315x260 ,(HxWxD) 775 x 315 x 172 775 x 315 x 191 mm Weight with Safety Switch 51.2%23.2 54.7%24.7 88.4 f 40.1 ib/kg . Coolfng Natural Convection Fans(user replaceable) Noise . <25 � <50 a dBA , Min:Max.Operetlng Temperature Range -13 to+140/-25 to+60(-40 to+60 version available�fi�) 'F/'C Protection Rating . . NEMA 3R = . . �3j For other regfonal seffings please contac[SolarEdge wppo2 �'�Llmited to 125%for locations where the yearly avenge high umperaarre is above 77'F/25'C and m 135%for lo�ations where ft Is helow 77'F/25'C. Fardetatled infortnatlon,refertn hCn:/lwww.solared�.us(files/odisliiwerter dc oversizine euide.odf �'�A higher curcent wurce may be used;the irrverter will Iimit tts input wrreM to the values sbted. �u Revenue grade IrnMer P/N:SEwaorA-USOOONNR2 �5�Rapid shutdown kR P/N:SE10W-N50.51 t�-40 version P/N:SE�oowA-US�NNU4 SUf15PEC - 1_..:.......::...... � � � �• � : � t - - �-•� �, � �, - - -