The work shall be carried out in accordance with the following supplemental instructions issued in accordance with the Contract
Documents without change in Contract Sum or Contract Time. Prior to proceeding in accordance with these instructions, indicate your
acceptance of these instructions for minor change to the Work as consistent the Contract documents and return a copy to the Architect.
DESCRIPTION:
The Following information is regarding Unit 6604 and deleting the exterior door from Exterior Balcony to the Elevator
Corridor and infill with the exterior horizontal lap siding wall assembly.
ARCHITECTURAL:
Sheets Tz.S Level 6:
i. i/Tz.S:Added plan callout reference for new plan 4/Tz.S.
z. 3/Tz.S Removed exterior door B6o5C type Ti between Elevator Corridor and Unit(B6o4)Exterior Balcony,.
3• 4/Tz.S New Enlarged plan Unit(6604):Travel Distance Plan with code summary indicating the unit is only
required to have one exit per sections ioi4.3 and section ioi5.i exception 1.
Sheet Az.o6:
i. Removed door B6o5C between Elevator Corridor and Unit(B6o4).
Sheet Az.o6-A:
i. Removed door B6o5C between Elevator Corridor and Unit(B6o4).
Sheet Az.zo:
i. Removed door B6oSC between Elevator Corridor and Unit(B6o4).
Sheet A4.oz(SK1):
i. Removed door B6o5C.
z. Infilled door opening with metal stud framing system and exterior horizontal siding assembly.
3. Added exterior horizontal flag note 5 for clarification.
4. Adjusted hot tub location to match plan location.
ATTACHMENTS:
,���,�zo��
a;_���or<
St:on,i�,.. , �-. . _ ._ .. . ._. . . _ „_..
DENVER PHONE: 303.861.5704
3003 LARIMER STREET FAX: 303.861.9230
DENVER BOULDER COLORADO SPRINGS � DENVER,COLORADO 60205 WWW.OZARCH.COM
�
� .
Architectural Sheets: Tz.S,Az.o6,Az.o6A,Az.zo and A4.o2-SKi