Loading...
HomeMy WebLinkAboutB11-0496 REV18 Architects Instructions � ARCHITECTURE ARCHITECT'S SUPPLEMENTAL INSTRUCTIONS � URBAN DESIGN INTERIOR DESIGN PROJECT NAME: Lion Vail(Strata Vail) ASI#: 044 � OWNER � ARCHITECT � CONSULTANT Q CONTRACTOR ❑ FIELD PROJECT#: 17oo4.i5 DATE OF ISSUANCE: oi/1z/zo16 ❑ OWNER: Lionshead Inn, LLC ARCHITECT: OZ Architecture, Inc. Patricio Burillo Rodrigo Cortina TO CONTRACTOR: PCL 705 West Lionshead Circle CONTRACT FOR: Construction Vail,CO 8i657 CONTRACT DATED: Mdy zoi4 The work shall be carried out in accordance with the following supplemental instructions issued in accordance with the Contract Documents without change in Contract Sum or Contract Time. Prior to proceeding in accordance with these instructions, indicate your acceptance of these instructions for minor change to the Work as consistent the Contract documents and return a copy to the Architect. DESCRIPTION: The Following information is regarding Unit 6604 and deleting the exterior door from Exterior Balcony to the Elevator Corridor and infill with the exterior horizontal lap siding wall assembly. ARCHITECTURAL: Sheets Tz.S Level 6: i. i/Tz.S:Added plan callout reference for new plan 4/Tz.S. z. 3/Tz.S Removed exterior door B6o5C type Ti between Elevator Corridor and Unit(B6o4)Exterior Balcony,. 3• 4/Tz.S New Enlarged plan Unit(6604):Travel Distance Plan with code summary indicating the unit is only required to have one exit per sections ioi4.3 and section ioi5.i exception 1. Sheet Az.o6: i. Removed door B6o5C between Elevator Corridor and Unit(B6o4). Sheet Az.o6-A: i. Removed door B6o5C between Elevator Corridor and Unit(B6o4). Sheet Az.zo: i. Removed door B6oSC between Elevator Corridor and Unit(B6o4). Sheet A4.oz(SK1): i. Removed door B6o5C. z. Infilled door opening with metal stud framing system and exterior horizontal siding assembly. 3. Added exterior horizontal flag note 5 for clarification. 4. Adjusted hot tub location to match plan location. ATTACHMENTS: ,���,�zo�� a;_���or< St:on,i�,.. , �-. . _ ._ .. . ._. . . _ „_.. DENVER PHONE: 303.861.5704 3003 LARIMER STREET FAX: 303.861.9230 DENVER BOULDER COLORADO SPRINGS � DENVER,COLORADO 60205 WWW.OZARCH.COM � � . Architectural Sheets: Tz.S,Az.o6,Az.o6A,Az.zo and A4.o2-SKi ISSUED BY: j��, ACCEPTED BY: —i�-= ARCHITECT: OZ Arc itec#�re CONTRACTOR: iliz/zoi6 Page z of z G:\aoo7\i7ooy Lionshead Inn�CA�AS1�A51_o44 Unit 605 Delete Exterior poor\ASI_oyq docx