HomeMy WebLinkAboutB14-0045 Blower Door report ���.������'��� � '��'`��l.�J����IliJ6.a"e�v�. Lion's Ridge Apartments — Building 4 Final Blower poor Report Test Date: April 13, 2016 Builder: Gorman & Company, Inc. Contact: Clint Tyrell; Chuck Collins Site Address: North Frontage Road, Vail, CO Site Visit By: Kristen Hartel Report By: Kristen Hartel Background The project goal is to undergo testing at final construction to determine if the project meets code requirements for air lealcage (3ACH50). ACH50 results as determined by depressurizing each unit are listed below. Site Observations To comply with RESNET sampling protocol, testing was completed on 12 randomly-chosen units in each building in a variety of conditions (i.e. firewall, unit type, and number of exterior walls). Outside air temperature during the test was approximately 55°F. Construction was finished. All windows were installed and latched shut. The blower door test was performed in the entrance door to each unit. Air Leaka e Results Unit Number Unit Type Unit Conditions CFM @ 50 Pa ACH 50 4106 D Firewall/Interior 375 2.58 4108 D Firewall/Interior 345 2.38 4109 AA Firewall/Interior 225 2.4 4111 C No firewall/Exterior 265 1.9 4205 C Firewall/Interior 345 2.5 4207 C Firewall/Interior 315 2.28 4209 A Firewall/Interior 218 2.33 4301 C No firewall/Exterior 375 2.7 4304 D Firewall/Interior 415 2.86 4306 D Firewall/Interior 440 3.03 4311 C No firewall/Exterior 300 2.17 4312 B Firewall/Interior 295 2.98 Please call with any questions or concerns. �.��stew +--ra�te� _9�0-�0�--���g K.�i,ste v�@,4cti,ve�vi,e��i.es.co vv�. Page 1 of 1 4/19/2016 P.O. Box 7627, Avon,CO 81620 I P: 970.306.4233 � F: 866.403.3485 � www.activeenergies.com