HomeMy WebLinkAboutB11-0496 REV27 cast iron sovent (2) APPROVED\\filesvr\jobs\21111028\CA\ca mech\Shop drawings\15400-52-R2 - Cast Iron Sovent Resubmittal 2\15400-52-R2 - Cast Iron Sovent Resubmittal 2 - BCER REVIEW.docm SUBMITTAL TRANSMITTAL TO:DATE:August 29, 2016 REFERENCE:Strata Vail Jeff Mapp OZ Architecture BCER PROJECT #:21111028 E-Mail:jmapp@ozarch.com SUBMITTAL #:15400-52-R2 SUBMITTAL NAME:Cast Iron Sovent Resubmittal 2 Date In Date Out Submittals & Tag #Section Manufacturer Re v i e w e d Re j e c t e d Re v i s e & Re s u b m i t Ma k e Co r r e c t i o n s As No t e d 08/25/16 08/29/16 Cast Iron Sovent Resubmittal 2 15400 Southeastern Specialty X BCER Internal Coordination: Life Safety Plumbing Mechanical Electrical Technology ☐ Completed ☒ N/A ☒ Completed ☐ N/A ☐ Completed ☒ N/A ☐ Completed ☒ N/A ☐ Completed ☒ N/A These are transmitted as indicated: ☐ Checked as Noted (See Comments below) ☒ Checked as Noted (See Submittals) SUBMITTAL REVIEW COMMENTS: REVIEWED BY: Brook Corning kwedding New Submittal Submittal Cover Sheet X Project:Strata - Vail OZ Architecture From:PCL Construction Services, Inc. 3003 Larimer Street 953 S Frontage Rd West Denver, CO 80205 Suite 302 Vail, CO 81657 SPECIFICATION SECTION NO. & DESCRIPTION (Cover only one section with each submittal) PRIORITY STATUS CODES 1.4 C - Respond within 15 days CONTRACTOR REMARKS:A/E REMARKS: CONTRACTOR'S CERTIFICATION: NAME AND SIGNATURE OF CONTRACTOR REPRESENTATIVE:NAME AND SIGNATURE OF REVIEWING AUTHORITY:Date: 4 5 8 18 20 19 17 12 13 ACTION TAKEN A - Approved B - Approved as Noted C - Revise and Resubmit D - Not Approved A - Immediate Response B - Respond within 10 days C - Respond within 15 days Submittal No: Previous Submittal No: Date:Resubmittal CONTRACT REF. DOCUMENT Spec Paragraph Number e. Drawing Sheet Number f. 15400 - Plumbing Systems PCL Construction Services Inc. Contractor Project No: 5001410 15400-52-R1 To: Description of Item Submitted (Type, size, model number, etc.) b. 1 Shop Drawings - Cast Iron Sovent - Southeastern Specialty 2 3 Action Submittal Type c. Item a. I certify that the above submitted items have been reviewed in detail, are correct, and in general conformance with the Contract Drawings and Specifications except as otherwise noted. 6 7 Please see attached PCL Submittal Review Notes Page. 14 16 9 10 36 23 15 24 25 26 31 21 27 30 28 29 22 32 33 34 37 38 11 35 39 40 41 42 43 44 45 46 47 57 48 49 50 55 51 56 52 53 54 60 58 59 8/15/16 PCL CONSTRUCTION SERVICES, INC. 953 S. FRONTAGE RD WEST, SUITE 302, VAIL, COLORADO 81652 TELEPHONE: (970) 470-6044 PCL Initial Submittal Review Notes Strata - Vail PCL Project No. 5001410 Subcontractor: RK Mechanical Submittal #: 15400-52-R2 Date: 7/12/16 Revisions: Revision Dates: Specification Section: 15400 – Plumbing Systems Item Description: Cast Iron Sovent Re-Submit – Southeastern Specialty Action: Y Variance Request (Y/N): N If so, why?: Notes: Notes to OZ Architecture and design reviewers include: · Please find attached shop drawings for Cast Iron Sovent Re-Submit for Southeastern Specialty. o The shop drawings included herein reflect the comments as provided both by Conine and Southeastern Specialties. Note that the BCER comments addressed below were incorporated into the original coordination shop drawings in October/November 2015. o Upon Southeastern review further revisions were required and the risers affected were 17A, 18A, 27A, and 4B. The revised drawings are provided herein and clouded in red with clarification comments. o BCER Comment Responses (The comments below are noted and identified on each correlating riser diagram page in green). 1. Calculations for Stacks 12A & 17A/Sheet P2.05-A has been verified. 2. Calculations for Stacks 27A/Sheet P2.01-A has been verified. 3. Calculations for Stacks 31A has been verified. 4. Calculations for Stack 34A has been verified for proper connection distances for branch connections. 5. Calculations for Stack 36A has been verified. 6. RK Mechanical and Southeastern Specialty has confirmed the drawings and will arrange for a field install walk and will invite BCER/Oz. Reviewed By: Justin Burkhardt 3800 Xanthia Street Denver, Colorado 80238 ph: 303.355.9696 fx: 303.355.8666 www.rkmi.com Transmittal of Submittal August 15, 2016 PCL Construction Services, Inc. 2000 South Colorado Blvd, Tower Two, Suite 2-500 Denver, CO 80222 Attention: Chuck Kay Project Engineer Reference: Strata Vail 705 West Lionshead Circle Subject: Submittals for Specification Section 15400 Dear Chuck: RK Mechanical is providing PCL Construction Services, Inc. the enclosed submittals for Specification Section 15400 - Cast Iron Sovent - Southeastern Specialty, as listed below: ITEM COPIES REV SUBMITTAL DESCRIPTION STATUS DUE BACK 1 1 2 Cast Iron Sovent - Southeastern Specialty For Review 08/18/2016 Your immediate review and processing is requested to ensure these submittals are returned back to RK Mechanical on or before the DUE BACK date(s) listed above. We are available to discuss any comments or questions you may have concerning these submittals. Sincerely, RK Mechanical Justin Burkhardt xc: RK Job # 4009- Main Files Date Submitted: August 15, 2016 Date Due Back: August 18, 2016 RK Submittal No.: 15400.52 - 2 Specification Section: 15400 - Cast Iron Sovent - Southeastern Specialty Project Name: Strata Vail 705 West Lionshead Circle General Contractor: PCL Construction Services, Inc. 2000 South Colorado Blvd, Tower Two, Suite 2-500 Denver, CO 80222 Mechanical Contractor: RK Mechanical 3800 Xanthia Street Denver, CO 80238 Subcontractor/Supplier: RK Mechanical, Inc. 3800 Xanthia Street Denver, CO 80238 3800 Xanthia Street Denver, Colorado 80238 ph: 303.355.9696 fx: 303.355.8666 www.rkmi.com Submittal Cover Sheet ITEM COPIES REV SUBMITTAL DESCRIPTION DRAWING MANUFACTURER 1 1 2 Cast Iron Sovent - Southeastern Specialty SE Specialty Br a n c h l i n e s i z e in c r e a s e d f r o m 3" t o 4 " , a e r a t o r to s e c o n d co m b o . Ho r i z o n t a l d r a i n l i n e s i z e in c r e a s e d f o r m 3 " t o 4 " do w n s t r e a m o f t h e W C co m b o . t o b u i l d i n g d r a i n . Br a n c h l i n e s i z e in c r e a s e d f r o m 3 " t o 4" , a e r a t o r t o W C co m b o . Pi p e s i z e in c r e a s e d f r o m 3 " to 4 " , a e r a t o r t o co m b o .