HomeMy WebLinkAboutDRB16-0421_A116_1478908303.pdfScale
Date
Drawn By
Checked By
Project Number
1/16" = 1'-0"
7/14/2016
9:18:21 AM
A116
LEVEL 6 FINISH
PLAN / DOORS /
COMMON SPACE
WINDOWS
VAIL
SPA
CONDOMINIUMS
MEW
MEW
02/19/2016
VSRP - 2016
710 W. LIONSHEAD
CIRCLE
1/16" = 1'-0"
1 LEVEL 6 FINISH PLAN - GMP G.C. SCOPE
No. Description Date
1 PROGRESS/PRICIN G 2 OCT
15
2 DRB REVIEW 12 OCT
15
3 PROGRESS/PRICIN G 2 23 DEC
15
4 CDs/PERMIT 21 JAN
16
5 CDs/PERMIT 2 19 FEB
16
GENERAL PLAN NOTES
1. ALL DIMENSIONS ARE TO FACE OF STUD U.N.O.
2. FURNITURE IS NIC, U.N.O.
3. ALL BUILDING AREAS ARE FULLY SPRINKLERED PER NFPA-13.
SPRINKLER PROTECTION SHALL BE PROVIDED FOR EXT
BALCONIES AND IN ROOF TRUSSES AND OTHER SPACES REQ'D
BY CODE. PROVIDE A DRY OR GLYCOL SYSTEM FOR RF TRUSSES
AND GARAGE AND OTHER UNCONDITIONED AREAS.
4. PARKING LEVELS ARE FULLY SPRINKLERED PER NFPA-13.
5. COORDINATE LOCATION OF EXISTING KNOX BOXES WITH FIRE
DEPT- 1 EXISTING BOXES ARE AT FDC LOCATIONS
6. PENETRATIONS AT DOUBLE-T AND TOPPING GARAGE LID SHALL
BE COORDINATED WITH STRUCTURAL.
7. PENETRATIONS AT ROOF TOP AIR CONDITIONING UNITS UNITS
SHALL BE COORDINATED WITH MECHANICAL CONTRACTOR FOR
SIZE AND LOCATION.
8. DIM FROM EDGE OF DOOR FRAME TO EDGE OF ADJACENT
PERPENDICULAR WALL SHALL BE 4" U.N.O.
9. DRYWALL PART'NS BTWN CONDITIONED OCCUPIED SPACES &
GARAGE SHALL HAVE VAPOR BARRIER ON WARM SIDE (AIR INFIL.
BARRIER ON EXT. WHERE SIDING SHOWN).
10. ALL PART'NS IN OR ADJACENT TO PARKING GARAGE TO BE
CONSTRUCTED ON A 5 1/2" x 6" CONC CURB, RE: X/A5.04.
11. ALL BUILDING UTILITY DOORS SHALL BE EITHER REPLACED
IN-KIND W/ REGARD TO RATINGS, HARDWARE, AND FINISHES, OR
KEPT AS-IS. DETERMINED CASE BY CASE - SEE LOCATIONS ON
PLANS
12. ALL CORRIDOR/PARTITIONS SHALL BE ACOUSTICALLY
CONSTRUCTED TO MATCH EXISTING, U.N.O
13. WHERE "CLEAR" IS CALLED OUT ON A DIMENSION, PROVIDE DIM
NOTED FROM FACE OF FINISH TO FACE OF FINISH.
14. (NOTE DELETED -NO NEW STEEL BEARING COLUMNS BEING
ADDED)
15. ALL STRUCT STL BEAMS (EXCEPT AT BALCONIES) TO BE 1-HR
RATE OR MATCH EXISTING
16. REFER TO DETAILS FOR SPECIFIC OR PROPOSED FLOOR
TRANSITIONS
17. 406.2.2, IBC. CLEAR HEIGHT. THE CLEAR HEIGHT OF EACH FLOOR
LEVEL IN VEHICLE AND PEDESTRIAN TRAFFIC AREAS SHALL NOT
BE LESS THAN 7 FEET (2134 MM). VEHICLE AND PEDESTRIAN
AREAS ACCOMMODATING VAN-ACCESSIBLE PARKING REQUIRED
BY SECTION 1106.5 SHALL CONFORM TO ICC A117.1. 8'-2" MIN.
CLEAR HEIGHT
18. PROVIDE PRECAST SPLASH BLOCK @ ALL DOWNSPOUTS
TERMINATING IN LANDSCAPE OR ON FLAT MEMBRANE ROOFS.
19. ALL COLUMNS SHALL BE INDIVIDUALLY PROTECTED FOR 1-HR
RATING, WHEN PART OF PARTITION ASSEMBL
20. ALL EXISTING GLU-LAMS ARE CONSIDERED NON-STRUCUTRAL
AND SHALL BE WRAPPED WITH WEATHER RESISTIVE BARRIER
AND BE CLAD WITH COPPER
21. ALL STOREFRONT AND SLOPED GLAZING TO HAVE .28 U-VALUE
22. ALL NEW RESIDENTIAL DOORS AND WINDOWS TO HAVE .30
U-VALUE
23. SPECIAL INSPECTIONS SHALL INCLUDE SITE-WELDED STEEL AT
ROOF CAPS, AND REBAR REINFORMENT AT POOL AREA
CONCRETE WORK
COMMON WINDOW LOCATIONS NOTED ON PLAN - SEE WINDOW PROVIDERS PACKAGE FOR MORE INFORMATION
SEE A603 FOR PG-01 INFORMATION
GMP FINISHES:
-CARPET AS CALLED OUT
-TILE AS CALLED OUT
-TRIM GLAZED
-REMOVE CROWN/REPAIR ADJACENT WALL/CEILING AREAS
-WALLS PAINTED
-DOORS REFINISHED AS DETERMINED BY OWNER
DRB
APPROVED
10/27/2016
12:00:00 AM