Loading...
HomeMy WebLinkAboutB16-0053 photos.xlsxBay/Bow Window Frame Order Form Fax to Bay World - 419-522-8768, Phone 888-767-0010 Renewal Location Home-Owner Frame for new 2010 Casement Windows Unit Size Wood Type Seat Design Type Wood Roof Style Note: Back Height will be approximately two-thirds of window exterior projection if not spedified If ordering the Bay Frame with a different Jamb Depth than the True Wall Thickness with a Roof Roof Clad Kits Interior Casing Factory Finish Knee Braces Avonite® Solid-Surface Seats Low Voltage Recessed Lights Plastic Laminate Interior Seat All Bay/Bow Frames include DuPont TyVek® Weatherization Wrapping. Exterior Cladding must be applied in the field Comments Renewal by Andersen Location Address Contact Last Name Bay/Bow Quantity Yes Width Measure for Exact Frame Make Size, Width & Height Measure Total Wall Thickness, from Inside Wall Surface to Edge of Exterior Face Trim Exterior Proj. Limitation Insulate to Wall Sheath Insulate to Specific Distance from Inside (No Exterior Stops) Non Insulated Specific Roof Back Height Roof Off-Set Edge Banding 6" Stacked Col. Copper Masonry Flashing Quantity Light Oak White Oak None Painted Interior Specify Paint Color Phone # Order Date " Brushed Nickel Height X Quantity First No Standard R-9 Hip Style Copper with Incralac Applied 2-1/4" Colonial Specify desired Faceboard Width if not 6" Standard Dark Oak Beige " Birch Specify RbA Color Cameo White Sandstone Custom 1 7/8" Int. Stops, used with Universal Nailing Flange Specific Exterior Proj. Desired Fully Insulated, Entire Seat Request Ship Date Choose from 1, 2 or 3 Polished Brass Fax # " " Painted Aluminum Stained Interior Specify Stain Color Colonial Cherry Other Agreement # Jamb Depth Deluxe R-21 Concave Style Specify Alum. Color 3-1/2" Colonial Deluxe Store # Beach Dusk White Yes " " " " " 25° Angle Bay 35° Angle Bay 45° Angle Bay Four-Lite Bay Five-Lite Bay Four-Lite Bow Five-Lite Bow Six-Lite Bow 90° Box Bay 90° Bump-Out 1:2:1 Ratio 1:1:1 Ratio 1:2:1 Ratio 1:1:1 Ratio 1:2:1 Ratio 1:1:1 Ratio 25° Style 35° Style 45° Style 25° Style 35° Style 45° Style 10° Style 15° Style 10° Style 15° Style 10° Style 15° Style STYLE AN CS CD CT CT DB COTTAGE ORIEL COTTAGE ORIEL FW GL GL GT GT PW MIN W 16 16 31.125 43.1875 60.0625 16.5 16.5 16.5 16.5 16.5 16 22 37 37 46 10.5 WHO MIN W 23.5 43.0625 68.625 90 MAX W 60 40 79 118 120 48 48 48 48 48 60/80 72 56 84 84 106 EXT W 54 54 54 54 54 96 108 144 144 MIN H 17 17 17 17 17 27.75 32.875 32.875 38 38 17 10.5 10.5 10.5 10.5 10.5 MAX H 48 80 80 80 80 96 81.25 81.25 73.75 73.75 60/80 80 80 80 80 106 EXT H 72 60.875 60.875 55.375 55.375 72 72 72 72 RATIO 1:1:1 1:2:1 1:1 2:3 3:2 2:4 4:2 1:1 1:2 1:1:1 1:2:1 MIN UI 22 MAX UI 96 140 168 Gliding Active/Stationary: GAS Fractional Gliding Active/Stationary: FGAS Gliding Picture Window: 1:1:1 1:2:1 GLIDING WINDOWS: GL GL FRACTIONAL GT 1:1:1 GT 1:2:1 Width 70.375 Width Width MIN W 22 37 37 46 Height 34 Height Height CO Width 30.8535 CO Width CO Width MAX W 72 56 84 84 CO Height 29.507 CO Height CO Height EXT MAX W 96 108 144 144 CO Area(SqFt) 6.32218211458333 CO Area(SqFt) CO Area(SqFt) MIN H 10.5 10.5 10.5 10.5 MAX H 80 80 80 80 EXT MAX H 72 72 72 72 RATIO 1:1 1:2 1:1:1 1:2:1 Sloped Sill DB Inserts: 1:1 Sash Ratio Cottage 2:3 Cottage 2:4 Oriel 3:2 Oriel 4:2 Flat Sill DB Inserts: 1:1 Sash Ratio Cottage 2:3 Cottage 2:4 Oriel 3:2 Oriel 4:2 DB Full Frame: 1:1 Sash Ratio Cottage 2:3 Cottage 2:4 Oriel 3:2 Oriel 4:2 DOUBLE HUNG DB 1:1 COTTAGE 2:3 ORIEL 3:2 COTTAGE 2:4 ORIEL 4:2 Width Width Width MIN WIDTH 16.5 16.5 16.5 16.5 16.5 Height Height Height Check Rail Check Rail Check Rail MAX WIDTH 48 48 48 48 48 CO Width CO Width CO Width EXT MAX W 54 54 54 54 54 CO Height CO Height CO Height MIN HEIGHT 27.75 32.875 32.875 38 38 CO Area(SqFt) CO Area(SqFt) CO Area(SqFt) MAX HEIGHT 96 81.25 81.25 73.75 73.75 EXT MAX H 72 60.875 60.875 55.375 55.375 RATIO 1:1 2:3 3:2 2:4 4:2 Sub PasswordBreaker()     'Breaks worksheet password protection.     Dim i As Integer, j As Integer, k As Integer     Dim l As Integer, m As Integer, n As Integer     Dim i1 As Integer, i2 As Integer, i3 As Integer     Dim i4 As Integer, i5 As Integer, i6 As Integer     On Error Resume Next     For i = 65 To 66: For j = 65 To 66: For k = 65 To 66     For l = 65 To 66: For m = 65 To 66: For i1 = 65 To 66     For i2 = 65 To 66: For i3 = 65 To 66: For i4 = 65 To 66     For i5 = 65 To 66: For i6 = 65 To 66: For n = 32 To 126     ActiveSheet.Unprotect Chr(i) & Chr(j) & Chr(k) & _         Chr(l) & Chr(m) & Chr(i1) & Chr(i2) & Chr(i3) & _         Chr(i4) & Chr(i5) & Chr(i6) & Chr(n)     If ActiveSheet.ProtectContents = False Then         MsgBox "One usable password is " & Chr(i) & Chr(j) & _             Chr(k) & Chr(l) & Chr(m) & Chr(i1) & Chr(i2) & _             Chr(i3) & Chr(i4) & Chr(i5) & Chr(i6) & Chr(n)          Exit Sub     End If     Next: Next: Next: Next: Next: Next     Next: Next: Next: Next: Next: Next End Sub CS: Std Hinge (fully opened) Wide Open Hinge (fully opened) CD: Std Hinge (fully opened) Wide Open Hinge (fully opened) CT: 1:1:1 Std Hinge (fully opened) 1:1:1 Wide Open Hinge (fully opened) 1:2:1 Std Hinge (fully opened) 1:2:1 Wide Open Hinge (fully opened) CASEMENT WINDOWS CS CD CT 1:1:1 CT 1:2:1 Width 28.75 Width Width MIN W 16 31.125 43.1875 60.0625 Height 46.5 Height Height W-O-H MIN W 23.5 43.0625 68.625 90 CO Width 21.75 CO Width CO Width MAX W 40 79 118 120 CO Height 41 CO Height CO Height CS CD CT CT CO Area(SqFt) 6.19270833333333 CO Area(SqFt) CO Area(SqFt) MIN HEIGHT 17 17 17 17 MAX HEIGHT 80 80 80 80 RATIO 1:1:1 1:2:1 Specialty Window Non-Standard Product Request (NSPR) Form (Please use separate form for each window) Type what is non-standard with this request: Sketch the unit and/or grille patterns in box below. Please provide thorough dimensions. CH-Chord CI-Circle CT-Circle Top EL-Equal Leg Arch HX-Hexagon OC-Octagon PE-Pentagon PP-Peak Pentagon QC-Quarter Circle RT-Right Triangle SL-Springline TP-Trapezoid TR-Triangle UL - Unequal Leg Arch Custom Affiliate Name: Contact Person: Email Address: Date Submitted Insert Full Retail Location Information Canvas Cocoa Bean Dark Bronze Forest Green Sandtone Terratone White Black Red Rock Picture Frame Traditional Insert PF Insert TR None 1 Piece 2 Piece None Phone # Canvas Sandtone Terratone White Pine Oak Maple L-Trim Wide L-Trim Overfit All Sides Overfit Arch Only Overfit No Sill None Store # Colonial Flat Quarter Round Shoe None 4/4" 5/4" None 4-9/16" 6-9/16" Custom Maple Oak Pine Canvas Natural (Pine, Oak, Maple) Sandtone Terratone White This is only a request and not a valid order until approved by Renewal by Andersen Corporation, signed by the Affiliate below and attached to an order form(s). A signature indicates acceptance of this NSPR and any applicable support documents. yes no RbA CG Customer Service Dept use only Status/Date: Reviewed by: Price: Lead-time: Approval drawings were created: WM324 WM351 WM361 WM366 WM444 WM445 WM356 S332 None All Sides Arches Only No Sill Project Name: Project Type: Number of NSPR Units: Total Unit Opportunity: Floor Plan ID # Quantity Product Style Frame Type Unit Width Overall Unit Height Left Leg Height Right Leg Height Exterior Color Interior Color Glass Interior Trim Extension Jamb Thickness Extension Jamb Wall Depth Extension Jamb Species Extension Jamb Color Project Information Unit Information Type Name Here (required to process) HP HPT X3 X3T S2 S2T DP DPO DPOT DPT HPO HPOT S2O S2OT HPRN HPRT S2RN S2RT HPGC HPGT S2GC S2GT HPER HPET S2ER S2ET CSTM PDLT HPLT HPLT S2L S2LT DPL X3O X3TO X3FERN X3TFERN X3REED X3TREED X3CSCAD X3TCSCAD Colonial Custom Gothic Open Hub Sunburst Prairie Renaissance Sunburst None NSPR # Casing Profile Casing Species Casing Location Brickmould Style Brickmould Location Drip Cap Exterior Trim Grille Pattern Grille Type Grille Profile # of Lites Wide # of Lites High # of Spokes # of Hubs NSPR # FDL GBG INTW Custom Date GBG-Standard GBG-Wide INTW-HD INTW-HDW FDL-HD FDL-HDP FDL-HDW FDL-HDWP Approved Denied incomplete Non-Standard Product Request (NSPR) Form (Please use separate form for each window) Type what is non-standard with this request: Sketch the unit and/or grille patterns in box below. Please provide thorough dimensions. CH-Chord CI-Circle CT-Circle Top EL-Equal Leg Arch HX-Hexagon OC-Octagon PE-Pentagon PP-Peak Pentagon QC-Quarter Circle RT-Right Triangle SL-Springline TP-Trapezoid TR-Triangle Custom CS CD CT AN FW DB GW GS GPW PW SPW (use SPW form) Affiliate Name: Contact Person: Email Address: Date Submitted Insert Full Retail Location Information Canvas Cocoa Bean Dark Bronze Forest Green Sandtone Terratone White Black Red Rock Picture Frame Traditional Insert PF Insert TR None Phone # Canvas Sandtone Terratone White Pine Oak Maple L-Trim Wide L-Trim Overfit All Sides Overfit Arch Only Overfit No Sill None Store # Equal 1:1:1 1:2:1 Cottage 2:3 Cottage 2:4 Oriel 3:2 Oriel 4:2 Custom None Maple Oak Pine Canvas Natural (Pine, Oak, Maple) Sandtone Terratone White None 1 2 This is only a request and not a valid order until approved by Renewal by Andersen Corporation, signed by the Affiliate below and attached to an order form(s). A signature indicates acceptance of this NSPR and any applicable support documents. Yes No Floor Plan ID # Quantity Product Style Frame Type Sill Angle (DB only) Extension Jamb Receiver Brickmould Style Sash Ratio Unit Width Unit Height Exterior Color Interior Color Glass (Overall or S1) Glass (S2) Lifts/Pulls Locks RbA CG Customer Service Dept use only Status/Date: Reviewed by: Price: Lead-time: Approval drawings were created: All Sides Arches Only No Sill Project Name: Project Type: Number of NSPR Units: Total Unit Opportunity: Project Information Unit Information Type Name Here (required to process) HP HPT X3 X3T S2 S2T DP DPO DPOT DPT HPO HPOT S2O S2OT HPRN HPRT S2RN S2RT HPGC HPGT S2GC S2GT HPER HPET S2ER S2ET CSTM PDLT HPLT HPLT S2L S2LT DPL X3O X3TO X3FERN X3TFERN X3REED X3TREED X3CSCAD X3TCSCAD Custom Sash Operation Screen Grille Pattern Grille Type Grille Profile # of Lites Wide (S1/S3) # of Lites High (S1/S3) # of Lites Wide (S2) # of Lites High (S2) Colonial Farmhouse Prairie Modified Prairie Custom None Flat Sill 1 2 2 3 4 5 6 7 8 9 10 11 12 13 14 None NSPR # NSPR # FDL GBG INTW Custom Date GBG-Standard GBG-Wide INTW-HD INTW-HDW FDL-HD FDL-HDP FDL-HDW FDL-HDWP Fiberglass Half Fiberglass Aluminum Half Aluminum TruScene Half TruScene Dual TruScene VS - Veneer Custom None Left Right LR LS SR SS LSR LSS SSR SSS Approved Denied Incomplete Municipality Permitting Requirements Color Key: Municipality: Arapahoe Arvada Aspen Breckenridge Boulder County Bow Mar Brighton Broomfield Canon City Carbondale Castle Pines North Centennial Central City Cherry Hills Village Cheyenne Clear Creek County Columbine Valley Commerce City Dillon/Summit County Douglas Eagle County Eagle Town of Edgewater Englewood Estes Park Fireston Frisco Georgetown Glenwood Springs Golden Grand County Grand Junction / Mesa County Greenwood Village Idaho Springs Lafayette Lakewood Longmont Louisville Manitou Springs Mead Morgan County Milliken Nederland New Castle Northglenn Parker Pitkin Platteville Rifle Rio Blanco County Routt County Severence Silverthorn/Summit County Steamboat Springs Sterling Summit County Superior Vail Westminster Wheat Ridge Windsor No Permit Unless Structural: Municipality: Adams Aurora Avon Berthoud Boulder City Castle Rock Cedaredge Chaffee County Denver Eaton Elbert Erie Evans Fairplay Fort Collins Fort Lupton Foxfield Frederick Fremont Garfield County Gilpin County Greeley Gunnison Johnstown Jefferson Larammie Wyoming Larimer County Lincoln County Littleton Lochbuie Lone Tree Loveland Montrose Park County Peyton Pikes Peak Pueblo Severance Teller Thornton Weld County Woodland Park Egress Required Egress Requirements: Must meet current. Like for like allowed. Must meet egress Like for like ok. Must meet current. Like for like allowed. Must meet current. Like for like allowed Must meet egress Like for like allowed. Like for like allowed. Historical. Must meet current code See note on right Must meet current. Must meet current. Like for like allowed. Must meet egress Must meet current. Like for Like allowed Must meet current code Like for like ok Like for like allowed. Must meet current. Must meet curent Must meet curent egress Historical. Like for Like allowed Must meet current. Must meet egress Like For Like allowed. Need to have approval from each city prior to getting permit Like for like ok Basement muste meet curet egress though Like for like ok Should meet current. Some exceptions allowed. Like for like allowed. Must meet egress Like for like allowed. Exception in Basements Historical. Must meet curent Must meet curent Like for like allowed Must meet current code Like for like allowed. Must meet current. Must meet current Like for like ok Must meet egess Must meet egress Must meet egress Like for like ok Must meet curent Egress Must meet egress Must meet curent Egress Must meet curent egress, 2012 IRC Must meet current. Must meet curent eress Like for like ok. Exception is basements Like for like allowed. Must meet egress Egress Requirements: Like for like allowed w/o permit. Like for like allowed w/o permit. Like for like ok w/o permit Like for like ok w/o permit 2012 ICC. Like for like allowed w/o permit. Like for like ok w/o permit Like for like allowed Like for like allowed w/o permit. Like for like allowed Like for like allowed Like for like allowed Like for like allowed Like for like allowed Like for like allowed Like for like allowed Like for like allowed Like for like allowed Like for like allowed Like for like allowed Like for like allowed Like for Like allowed Like for Like allowed Like for like allowed w/o permit. Like for like allowed Like for like allowed Like foe Like allowed Like for like allowed. Like for like allowed Like for like allowed Like for like allowed only need permit if structural change Like for like allowed w/o permit. Like for like allowed w/o permit. Like for like allowed w/o permit. Like for like allowed Like for like allowed w/o permit. Like for like allowed w/o permit. Like for like allowed w/o permit. Like for like allowed w/o permit. Permit required Phone Number: 720-874-6600 720-898-7620 970-429-2748 970-453-3180 303-441-3926 720-301-1877 303-655-2017 303-438-6370 719-276-5292 970-963-2733 303-705-0227 303-754-3321 303-582-5251 x402 303-783-2721 307-637-6265 303-679-2333 303-795-1434 303-289-3790 970-468-2403 303-660-7497 970-328-8730 970-328-9655 303-235-8300 303-762-2356 970-577-3726 303-774-1388 ext. 105 970-668-5276 303-569-2555 970-384-6400 303-384-8151 970-725-3347 970-244-1631 303-486-5783 303-567-4421 303-665-5588 303-987-7500 303-651-8332 303-335-4584 719-685-4398 303-774-1388 ext. 105 970-542-3526 970-660-5043 303-258-3266 970-984-2311 303-450-8745 303-841-1970 970-920-5526 970-785-2245 970-665-6461 970-878-9450 970-870-5566 970-262-7367 970-870-5566 970-522-9700 970-668-3170 303-381-2028 970-479-2139 303-658-2075 303-235-2855 970-674-2400 Phone Number: 720-523-6825 303-739-7420 970-748-4011 970-532-2643 303-441-1880 720-733-3531 970-856-3123 719-530-5568 General: 720-865-2982 Inspector #: 720-865-2520 970-454-3338 303-621-3172 303-926-2780 970-475-1120 970-221-6760 303-857-6694 303-680-1544 720-382-5605 719-276-7460 970-625-5902 303-582-5831 970-350-9786 970-641-8151 970-587-4664 303-271-8260 307-721-5200 970-498-7700 719-743-2337 303-795-3750 303-655-9308 303-708-1818 970-962-2505 970-240-1437 719-836-42558 719-327-2880 719-327-2880 719-543-0002 719-687-3048 303-538-7250 970-353-6100 x35400 719-687-3048 Historical Area Email: sbyer@arapahoegov.com NO EMAILS Submit in person building_official@bouldercounty.org sgutierrez@brightonco.gov tdenning@broomfield.org tisrael@carbondaleco.net jan.ferrell@castlepinesgov.com kritter@centennialco.gov cityclerk@centralcitycolorado.us BLDG@co.clear-creek.co.us jdmccrumb@columbinevalley.org gthompso@douglas.co.us hjones@englewoodgov.org or jbrown@englewoodgov.org cphillips@estes.org rickw@townoffrisco.com or Ryanc@townoffrisco.com gtownclerk@earthlink.net jbrown@cityofgolden.net Check or cash only. comdev@gjcity.org Must submit in person. kstruss@greenwoodvillage.com johnw@cityoflafayette.com Basements are like for like. monicag@louisvilleco.gov Permits done by PPRBD / Elpaso county jmeyer@co.morgan.co.us cjohnson@safebuilt.com jsorensen@parkeronline.org Apps must be submited in person over the counter permit csquires@rifleco.org melodyh@silverthorne.org Permits done by Routt county larryr@co.summit.co.us Can submit permit online. trubotto@cityofwestminster.us mmackey@ci.wheatridge.co.us jliberty-anglado@windsorgov.com Email: rswarts@adcogov.org tmurray@auroragov.org plandevelop@bouldercoloraod.gov buildingcounter@crgov.com ccinfo@chaffeecounty.org developmentservices@denvergov.org ed.watkins@elbertcounty-co.gov kschaefer@evanscolorado.gov slindell@fcgov.com mike.cox@fremontco.com brad.mueller@greeleygov.com cdra@littletongov.org community.development@cityoflonetree.com jeanine jessie@pprbdorg mgurule@prbd.com sharonovao@co.teller.co.us buildings@cityofthornton.net pkamada@weldgov.com sharonovao@co.teller.co.us No permit unless strucutral work is being done Additional Notes: Will need pictures, floor plan drawing, home owner signiture. Permits applications can be emailed. There is a lot of stuff that has to go with the permit application. Windows that are less than 24" off the floor need to have child safety latches. They also require a mid insulation inspection before coil can be put on. Sill heights; distance from door. Permits must be submited in person. Check or cash only Can mail a check and they will mail the permit. We need to make egress if the curent opening will allow without doing any structural. online Can mail in the check. NO credit cards Must pick up the permits in person Need to have pictures of the exterior, also need to submit ufactor forms with application., along with the window worksheets and door forms. Can only pay by check or cash! Need pictues of all the exterior walls and inside pictures of windows. Need to have a .35 Ufactor or better. Permits need to be picked up in person Permits must be picked up Do not need a permit if just doing a door, must pick up the permit in person Check or cash only and must be submited and picked up in person. Permits must be picked up Permits must be picked up Permits must be picked up Permit must be picked up. We must have the signature of the home owner on the permit application. permits must be submited in person online Floor plans or drawing (need to note on the drawing what the room is for i/e bed room or living room), location of doors, exterior pictures. Permits must be submited in person and it needs to be schedualed with Vicky at least 1 day in advance! **IS IT IN FIRE ZONE? (all window might need to be tempered)Call Zoning planner @ 970-920-5482** Checks only. Can pay by credit card over the phone. There has to be a inspection of the opening before the window is closed up. Can only pay by check or cash. Can mail in the check and permit application, must pick up the permit in person Check only Need to have the HAO approval prior to submital of the permit. Need to have check and It is best to pick up the permit in person Can only pay by check or cash. Can mail in the check and permit application Check or cash only and must be submited and picked up in person. Must have blueprint style floor plan on a 11x17 paper, pictures of exsisting windows inside and out. Will also need there HOA form to be signed off by the HOA prior to submital. If it is a duplex the form must be signed by the neighbors! can fax but need to pick up in person Additional Notes: Like for like must not change anything that includes color! Checks only License Information: Renewal By Andersen Matthew Seiler License # AEC611 Matthew Seiler License # C-006522 Renewal By Andersen License # CON-14-0155 Matthew Seiler License # CL-10098 Matthew Seielr License # OL-15-10673 Matthew Seiler License # 17-000919 Matthew Seiler License # CN-977 Matthew Seiler License # CEN-15-08777 Matthew Seiler License # 2591 Business License- Window Warmth LLC License # 3601 Matthew Seiler License # C130355 Matthew Seiler License # 14B00509 Matthew Seiler License # 17987 Renewal By Andersen License # BCL-2014-S-339 Business License for Renewal By Andersen # 3558 Business License for Renewal By Andersen no # Matthew Seiler License # 5127 Renewal by Andersen License # GBC050076 Matt Seiler License # OL-15-02220 Matt Seiler License # GCC9911011 Matthew Seiler License # 19951 Renewal By Andersen License # C00000985 Matthew Seiler License # CL02558 Renewal by Andersen License # CL-299 Matthew Seielr ? On the License # Renewal by Andersen License # 15-CON-049 Matthew Seiler License # 15C01645 Matthew Seiler License # 14-066 Renewal by Andersen Business License # 30217 Matthew Seiler License # 0923 Renewal by Andersen Matthew Seiler License # 130831009 Matthew Seiler License # 130206 Renewal by Andersen Business License # BL5225 License Information: 2014 899484 00 CL Specialty Materials Customer Last Name: Job Site Evaluator: ID # Samples Provided (Y/N) Additonal Instruction: Photos: Specialty Material Sheet must be emailed to all warehouse personnel the same day the measure is turned in. Failure to do so will result in a mis-measure agains the Job Site Evaluator. Please offer as much information as possible to facilitate ordering. Style Qty Materials: First: Ordered: Vendor Date: 08/16/2017 Received: Speicalty Windows Order Form RETAIL LOCATION FLOOR PLAN ID FLOOR PLAN ID CONTINUED 4/4 UP TO 8 1/2" WALL DEPTH: PART # 7500608 5/4 UP TO 8 1/2" WALL DEPTH: PART # 7500614 RETAIL LOCATION NAME PHONE PURCHASE ORDER # REFERENCE UNIT SELECTION ID 24 18 9 2 INTERIOR TRIM OPTIONS EXT JAMBS ID 24 18 9 2 QTY 1 1 1 1 INT TRIM IF UNITS QTR QTR QTR QTR PRODUCT STYLE EL EL EL EL THICKNESS 5/4" OR 4/4" FRAME TYPE IF IF IF IF WALL DEPTH ORDER DATE SPECIES SALES REP ID MEASUREMENTS WIDTH 80.5 45.5 54.25 90.5 COLOR STORE NUMBER FAX OVERALL HEIGHT ADDTL QTY OF 10' PCS DEFERRED SHIP DATE TOTAL SW ON JOB CASINGS FULL FRAME UNITS PROFILE WM 324 WM351 WM361 WM366 WM444 CSA- ORDER ADDITIONAL PIECES BY ALLOCATION Fax or email to your Customer Service Representative LEFT LEG 28.75 27 29.5 17.5 SPECIES MAPLE (MP) PINE (PN) OAK (OK) RIGHT LEG 28.75 27 29.5 17.5 LOCATION ALL SIDES (AS) ARCHES ONLY (AO) NO SILL (NS) ADDTL QTY OF 10' PIECES COLOR/FINISH EXT FG FG FG FG HOMEOWNER EXTERIOR TRIM OPTIONS BRICKMOULD FF=TR OR PF IF=PF ONLY STYLE NOTES/SPECIAL OPTIONS LAST NAME ADDRESS CITY ADDITONAL FORMS ATTAHCHED INT PN PN PN PN LOCATION PRODUCT ORDER FORM GLASS GLAZING i89 i89 i89 i89 APPLIED HIGH ALT HIGH ALT? Yes or No Yes Yes Yes Yes DRIP CAP 1 PC 2 PC 2 PC 2 PC 2 PC 2 PC Breather tubes on all MULL SEQUENCE FULL FRAME ONLY - THIS OPENING (EXAMPLE 1A) NOTE: specialty window to other specialty window only. INSERT FRAME EXT TRIM L-TRIM=L WIDE L=WL WL WL WL WL SIGNED NSPR GRILLE SELECTIONS PATTERN Renaissance (REN) Sunburst (SUNB) Open Hub (OSUN) Gothic (GOTH) Colonial (COL) Prairie (PRA) CO STATE TYPE Grill Between Glass (GBG) Interior Wood (INTW) Full-Divided Light (FDL) FIRST NAME PHONE NO ELECTRONIC ORDER GRILLE ALIGNMENT Floor Plan ID of Adjacent Rectangular Window Below (Used for grille alignment only) Indicate the floor plan ID for the rectangular window under the SW from your product order form. PROFILE GBG: s(STD) or (W) INTW: (HD) or (HDW) FDL: (HD) , (HDP),(HDW) or (HDPW) # LITES WIDE # LITES HIGH ZIP SUNB OSUN ONLY # SPOKES PAGE _____ OF _____ # OF HUBS CHECK FOR SPECIAL OPT Style EL PE PP HX OC CI CT CH SL QC RT TR TP HS UL NSPR Grille REN SUNB OSUN GOTH COL PRA Location AS AO NS Frame Type FF IF Wall Depth 4 9/16" 5 1/4" 6 9/16" Custom Location AS AO NS Type GBG INTW FDL Color WH CV ST TT CB DZ FG BK RR Style NONE PF TR Profile STD W HD HDW HDP HDPW INT TRIM IF QTR COL SH FL INT Color WH CV ST TT PN OK MP Drip 1PC 2 PC L-Trim L WL Depth 5/4" 4/4" HA Yes No Glazing X3 X3T X3O X3OT X3Cscd X3CscdT X3Fern X3FernT X3Reed X3ReedT S2 S2O S2T S2OT S2Cscd S2CscdT S2Fern S2FernT S2Reed S2ReedT i89 i89O i89T i89OT i89Cscd i89CscdT i89Fern i89FernT i89Reed i89ReedT STYLE DB FLAT SILL DB SLOPED SILL GL/GT PW AN FW CS/CD/CT TOP 1.15625 1.15625 1.75 0.9375 1.25 1.25 1.25 SIDES 1.15625 1.15625 1.75 0.9375 1.25 1.25 1.25 SILL 1.40625 0.375 2.5 0.9375 1.25 1.25 1.25 CHECK RAIL 2.03125 2.03125 2.0625 RbA Structural Information Sheet Last Name: Address: City: Site Photos: State: First Name: Telephone: Zip: Existing Structure Jamb Depth: Bearing Wall? Floor: Deck Attached? Interior Wall Length: Ceiling Height: Exterior Finish: Electrical Work? New Product: Style: Additional Notes/Concerns: Site Technician: Cell: Email to structural department immediately. Eves? Width: Stories: Ext Wall Length: Projection: Closest Bearing Wall: Existing Fenestration: Extent: Eve Projection: Interior Finish: Height: Width: YES NO http://taxco.g1.com/COTaxLookup/CentrusDemo.aspx?user=dbancroft@renewaldenver.com http://enabledplus.com/Login?ReturnUrl=%2f Arapahoe County – http://www.arapahoegov.com/index.aspx?NID=1150 Jefferson County – http://jeffco.us/awiz/ Adams County – https://permits.adcogov.org/citizenaccess/ Centennial - http://www.centennialco.gov/Community-Development/property-search.aspx Sub PasswordBreaker()     'Breaks worksheet password protection.     Dim i As Integer, j As Integer, k As Integer     Dim l As Integer, m As Integer, n As Integer     Dim i1 As Integer, i2 As Integer, i3 As Integer     Dim i4 As Integer, i5 As Integer, i6 As Integer     On Error Resume Next     For i = 65 To 66: For j = 65 To 66: For k = 65 To 66     For l = 65 To 66: For m = 65 To 66: For i1 = 65 To 66     For i2 = 65 To 66: For i3 = 65 To 66: For i4 = 65 To 66     For i5 = 65 To 66: For i6 = 65 To 66: For n = 32 To 126     ActiveSheet.Unprotect Chr(i) & Chr(j) & Chr(k) & _         Chr(l) & Chr(m) & Chr(i1) & Chr(i2) & Chr(i3) & _         Chr(i4) & Chr(i5) & Chr(i6) & Chr(n)     If ActiveSheet.ProtectContents = False Then         MsgBox "One usable password is " & Chr(i) & Chr(j) & _             Chr(k) & Chr(l) & Chr(m) & Chr(i1) & Chr(i2) & _             Chr(i3) & Chr(i4) & Chr(i5) & Chr(i6) & Chr(n)          Exit Sub     End If     Next: Next: Next: Next: Next: Next     Next: Next: Next: Next: Next: Next End Sub LEGACY MULLING COMPONENTS NEW CS/AN/FW and GL's To adhere to egress our window must conform to the following rules: 1. 44" or less from top of sill to finished floor 2. Clear opening width must be minimum of 20" 3. Clear opening height must be minimum of 24" 4. Clear opening square footage must be 5.7 sq/ft or greater** **EXCEPTION** - windows on grade level can have clear opening of 5.0 sq/ft Doors Per the International Residential Code, all glass or panels in fixed, operable, swinging, sliding and bifold doors must be constructed from safety glass, regardless of size. In addition, any glass located adjacent to a door within a 24-inch arc of the door must be constructed from safety glass if the bottom edge of the glass is less than 60 inches above the walking surface. The only exception to these rules is decorative glass. and any glass opening too small for a 3-inch ball to pass through. While these IRC rules apply to all residences in the United States, San Francisco law also requires all glass located within 40 inches of an exterior or interior dwelling unit door be tempered or burglar-resistant. Windows Fixed or operable windows must include safety glass if they measure larger than 9 feet square, the bottom edge is less than 18 inches above the floor, the top edge is more than 36 inches above the floor, and there is a walking surface within 36 inches of the glass. Tempered glass is not required unless all four of these conditions are met. Stairs The IRC states that stair rails must be made from safety glass, as well as structural baluster panels and nonstructural infill panels. Tempered glass must be used for all glass adjacent to stairs, ramps and landings if the glass is located within 36 inches of a walking surface. and the exposed surface of the glass is less than 60 inches above any walkway. Finally, all glazing on surfaces adjacent to stairs must be made from safety glass when the surface sits within 60 inches of the bottom tread, and the glass is less than 60 inches above the nose of the bottom tread. Wet Areas The higher risk of slips and falls in wet areas means most glass located in bathrooms or near a hot tub or sauna must be constructed from safety glass. All glass in the bathroom or around a hot tub or sauna must consist of safety glass if the bottom edge is less than 60 inches above a standing or walking surface, such as the shower floor. In outdoor areas around a hot tub, all glazing must be constructed from safety glass if the bottom of the glass is less than 60 inches above the walkway and also within 60 inches of the edge of the water, according to the IRC.