HomeMy WebLinkAboutB16-0069 Old Unit specs.pdf Base unit dimensions — 48DJ008-014
FILTER ACCESS PANEL STD CORNER CORNER CORNER
(DISPOSABLE FILTERS) UNIT WUNITEIGHT ECONOMIZER WEIGHT WEIGHT W I HT
WEIGHT
[las) (C)
IP }0'-7 C1013
Lb Kg Lb Kg Lb Kg Lb Kg Lb Kg
d—z'-a 5!16'-4 -1'-0 5!e' 48DJEIDJD008 870 395 44 20 '189 86'161 73 239 109
(7191 (3201
1- f____------' 480JE/DJ13009 880 399 44 20 191 87 163 74 242 110
I N-1
i-I9 11/16' ACCESSCRY 4BDJE/DJD012 1035 469 44 20 225 102 192 87 285 129
I OPENING( 10567 HOOD FILTER 48DJD014 1050 476 44 20 228 103 195 88 289 131
1 HDR1-
ZONTAL' /
I i // \\\\ CORNER
R 11 SUPPLY-AIR\\ 1 I / OUTSIDE AIR WEIGHT "H" "J" "K"
t'-1 7/8' I OPENING •1 l 2'-27/16' UNIT (D)
13523 11 HORIZONTAL--I iL-- l // [671]
1- I 1 -,i E ��( 9Lb Kg Ft-in. mm Ft-In. mm Ft-in. mm
0'- 16' 48DJEJDJ0008 280 127 2-07/e 632 3.55As 1050 2-911he 856
r 3'-1' L0'-7" I_D'-S 11!16 48DJE/DJDO09 284 129 1-27/s 378 3-55Aa 1050 2.9"/ta 856
(940) / [1783 [1447 48DJE/DJDO12 333 151 2-10% 885 4-1,Ao 1253 3-0% 924
OUTSOF PANEL 4, / r 48DJD014 338 153 1-27/a 378 4-15/,e 1253 3-0% 924
SUPPLY AIR /6
RETURN AIR
/STD CONDENSATE DRAIN(INTERNALLY TRAPPED)
NOTES: RIGHT SIDE
1 Dimensions in[ )are in millimeters
2 0 Center of Gravity
3 '%/// Direction of airflow
2'-11 1/2 0'-3 9/16'
4 Ductwork to be attached to accessory roof curb [9021 (931
only FILTER/ECONOMIZER ACCESS PANEL\ NOMIZER
EAIR5 Minimum clearance(local codes or jurisdic- �tion may prevail): CONDENSER COILa Between unit,flue side and combustible sur- 3'-615/16r-5 7/8'
b Bottom to combustible surfaces(when not HOOD (4547
using curb),14 inches 0'-3 1/8'
c. Condenser coil,for proper afHlow,36-in one CORNER "A"-_, p 1 -.179) +
side,12 in the other The side getting the /' x. -� -CORNER 'a'
greater clearance is optional r/ -- -- -4-1-01-45011/2.
d Overhead, 60 in. to assure proper con- II .
denser fan operation p p 11 COILORATORI RETURYERTICALENINO I 1'-0 5/8' i„
e Between units,control box side,42 Inches , II 1 1 I 13201
f Between unit and ungrounded surfaces, ���// ii Up
-- d -. RETo[IN-A�Ii_-j
control box side,36 inches 4 -9 3/4• 11 E ___ , T }
g Between unit and block or concrete walls (14677 'I ALT. CONDENSATE ' �I 0"-2 9716"
end other grounded surfaces,control box HDRAIN OPENING I (65]
side,42 inches I1 IN BASEPAN i SUPPLY-10'-2 13/16'
LEFT AIR 1 2'-4 3/4" 2 1
h. Horizontal supply and return end,0 inches --I1— - 0 1 OPENING I 23
17307
6 With the exception of the clearance for the con- S I DE u I VERTICAL'
denser coil and combustion side,as stated in fiy II I /
notes 5a,b and c,a removable fence or bar- 1
I /
ricade requires no clearance 1199171!4 I I SUPPLY AIR
0'-2 15/1C,1 �"- 0'-4 11!16' "---•--
Connection Sizes 1757 'lI -11197
A Pia"bla[35]Feld Power Supply Hole �]_ 1'-2' °.(-153871/16-
13 2'h"Die[64]Power Supply Knockout CORNER 'D"•-- 2'-11 1/4'
[8951
C 1�/a'Dia(441 Charging-Port Hole �`-' 13557 0'-3 1/B" CORNER "C"
D '!a'Ole 122)Field Control Wiring Hole 3'-4 1/4' 4"-9 3/16 [797
E 1/+'-14 NPT Condensate Drain 110227 (2001
1/2'•14 NPT Gas Connection 40010006,009 ' 7'-3 3/8'
F x!."-14 NPT Gas Connection 480JE008.009,012, (22191
480JD012,014 FRONT
G 2'Dia[51)Power Supply Knockout
ELECTRICAL
DISCONNECT LOCATION
•,H• 0"-7 3/8'
• 0'-0 3/8'
11873 13/16' 1101 --p.
---------
(97) il}
1
2'-1' I
•i� A FLUE HOOD CONTROL 80X/ 1635] INDOOR-FAN MOTOR I I
5574 cONOLNSLR COIL G COMPRESSOR/ BLOWER ACCESS PANEL 1
/ / BURNER ACCESS ® i
' •J 2'-O 3/8" PANEL
(619
PIM
0'-4 " F-1-+ I
'+1 (101) - II .I
0'-4 9/16" d 0'-5 3/4" L- 3'-O 1
[1167 -4"-S 7/8"---.-- LI 461 FORKLIFT SLOTS
0'-2 9/16' (13697 0'-8 7/16' 0'-2 1/4" (571
1653 TYP _.. .. [2147 (V.IP 8 PLACES)
ill . • LEFT SIDE FRONT
• _ 9
ROOF CURB — 48DJ008-014
NOTES:
1
ROOF CURBEll UNIT SIZE 1 Roof curb accessory is shipped
ACCESSORY unassembled
S0D0901371 y 2 Insulated panels:1"thick polyurethane foam,
1211
48DJD/DJE008-012 13/4 lb density
2'-0•' 4BDJDO14 3 Dimensions in[ }are In millimeters.
�_ 50DJ901381 4 Root curb:16 gage steel.
r----1 [610J 5 Attach ductwork to curb (Flanges of duct rest
lesiiiiiimmummummer on curb)
��. 6 Service clearance 4 ft on each side
„,,s-, •
/I ` \ 7 r Direction of airflow
I -
\I .o`- - it
I ti U UNIT SIZE "B" "C" DRAIN "E" "F'" "G" CONNECTOR
tY /� r __...// HOLE GAS POWER CONTROL PKG.ACC.
a i 48D 0008,00',
• __,,/- 012&014 1-1016/is" 1-1015/i6" 1-3/4"[45] 3/d'[19]NPT 1'[25]NPT Vin"[19]NPT 50DJ901551
ns7 480JE008,009 [583] [583]
'0" &012 —_
1
1761
4. ri--1
12WIR 3-3 5/8-
(10061 UNIT 1 5/32"- .
" (30)
SUPPLY-AIR I ✓U� NAIL
OPENING GASKET
i'-3 1/4' 'C- I (SUPPLIED WITH CURB) . TYPICAL (4) SIDES
(387) 1 ––––– --�-. '4 0(t/16• COUNTER FLASHING
DUCT
(FIELD SUPPL lEU>
� J � (FIELD SUPPLIED)
0'0 7/16" ROOFING FELT
Ili) 2'-6 15/16' -:.I 11'-2 7/6" 0'-0 7/16" (FIELD SUPPLIED) SECTION "C-C'
(BOLT 11E05) (786) (3781 III)
(HOLT HEADS) SCALE 1:4
1761 CANT STRIP
°.-° [1117 __._ 4'-013/16" 0'-07/16' %. (F[E(.ROOFIIGEMATERIAL
(BOLT READS) (1240) (BOLT HEADS) \ (FIELD SUPPLIED)
f 4 B.%�.�
AA ' ,/ �\\ �\� —9f.F NOTE 2
! RIGID INSUt.AT1ON
(10 (F CELO SUPPL IGD)
immmmwwwwwwwwwwwwommumwoommommoommowit
I
/ .
! GAS
! SERVICE
/ PLATE 1 -8 3/16" ', `I "F"
0'-0 1/4'(7). . ..
/ [5137 +'-4 5%16" SERVICE
! (INSIDE) [110),+w`` PLATE "G.
.Aa- 0 [11 v` INSIDE) /, ma.
0'-4 9/16" \\ `�/ 1 -B 3/15 SPLATE(5133E
(116) Po I ! \ ►" (INSIOE)NI
'f,. SUPPLY AIR RETURN AIR ;� , 2 3/B
I ►
),,,t,,
........______,
VIEW 'A-A" p 1 A,,
MEANS OF
OFFLANGETO
BE ON =4 �``````�������`�`� `
. ..
ttz6a7 ..
• °nei .
VIEW '8' �^'' ♦ /•
y„,,, VIEW
ALL CORNERS) SEE VIEW "B`0 "^^ �
11