HomeMy WebLinkAboutB16-0104 cut sheet.pdf HIGH EFFICIENCY RESIDENTIAL BOILERS • I4IIEHT FIRE TUBE MEL =11 L7(1"7.L'71TM 4.1 "# 3.1�1hipruir C95% (CERTIFIED:-) AFUE EFFICIENCY Most Efficient DESIGNEE*ENGINEERED*ASSEMBLED 2016 ENERGY STAR www.energystar.gov ttLochlñvar. HIGH EFFICIENCY BOILERS&WATER HEATERS LOCHINVAR.COM I4IIBHT FIRE TUBE p:'The KNIGHT')floor-standing fire tube-boiler features reduced installation footprint for flexibility in boiler placement. Plus, all connections are on the top and left side, so KNIGHT is an easy drop-in replacement for older, less efficient boilers. Six models offer inputs from 55,000 to 285,000 Btu/hr. E I The KNIGHT fire tube boiler operates with low pressure drop.The design incorporates a small volume of water in the heat exchanger.This allows the boiler to be installed in a primary/secondary or a full-flow piped system.There is 'i no need to change the piping to accommodate the boiler.The boiler adapts to the system.This flexibility allows for a faster, more cost-effective boiler upgrade. I, 1, Modulation turndown up to 10:1 means the firing rate automatically changes 4. f, 1 as the heat load varies.A KHN110 KNIGHT boiler fires at its maximum 110,000 Btu/hr rate when load is highest,then "turns down"to as low as 10% (11,000 Btu/hr) as load decreases.A modulating boiler runs smoothly and efficiently,without frequent on/off cycling. I •- 1 ' OR ,i' •,ative Regulation . - - through the gas # or when gas -tio, 16 ilprIPF KNIGHT boilers can be installed with direct-vent air intake and exhaust runs up to 100 equivalent feet, using PVC,CPVC, • polypropylene or AL29-4C stainless steel vent pipe. CON,XUS® Ig. BOILER CONTROL, . - if — .x FROM ANYWHERE. From wherever you are,the CON•X•US®option lets y‘ • •t-capable device to link up with the SMART SYSTEM'"on an unlimited number of KNIGHT®boilers. 1 Do regular CON•X•US > Adjust setpoints,domestic > Status alerts via text or checks for all your KNIGHT hot water,reset curves, e-mail let you know when customers, and let them pump delays and more, a KNIGHT boiler needs know you're monitoring using the CON•X•US attention. their boiler's performance. interactive display. fr ! III With CON•X•US,you're always in touch and in control. ANDROID APP ON ` Download on th= •ptional CON•X•US control board is sold separately. Google play ii App Store MQG LTIMATE IN BOILER CONTROL & MONITORING dus 's most advanced boiler control system now includes the CON•X•US®Remote Connect an LOCH N LINK'" Flash Programming feature.See back cover for a complete list of S STEM'" functions and features. �— . 5544 6 2 t 99g.4 G E . LOCKOUT Q Blue Screen Normal system operation �tikliEf leM ° DM LERO VW�+ = .. _- 7 Yellow Screen Maintenance due shows BOLERO S41.1St.Um _ IG 24.0 �aootr d ,.��� . installer name&number ti.. i i N , ,,, f{L`i X Wil, .tnc t 'Pl `,. Red Screen Lockout mode .nr' Igicno,r c.11,4 re.! ',Wifl1 v4.i Pass rtsfr 5.114 reaLS i 5. MAA itternal i MAR Yj. .....----N, I NZ i - . • ... .., .. / c"7:.'r:..,...,.• R� . .. ..7 -7J.7;''---;."- lam ,a„ ijLOCH-N-LINKTM EASY USB FLASH PROGRAMMING Use a USB drive to name,store and easily manage multiple proven paramete Quickly upload them via the front panel port,reducing installation and progr. KNIGHT°BOILER DIMENSIONS AND SPECIFICATIONS* -- �� =_'moi A �� effialkor I'ir°yl B • IC •• • M D MI ll JIM . till • .I ,-`i-, wig s 16" UIn �t 0 0 I.— E -. - ± ± Input MBH Heating Model Ca acity Net Gas Water Air Vent Shipping Number Min Max AFUE% MBH MBH A B C D E F 6 H I J Connect. Connect. Inlet Size Weight . 8.3 55 95 51 44 6" 8-3/8" 11-1/8" 10-1/2" 13-1/4" 37-1/2" 32-5/8" 32-1/4" 13-1/4" 3-3/8"- KHN085 8.5 85 95 79 69 6" 8-3/8" 11-1/8" 10-1/2" 13-1/4" 37-1/2" 32-5/8" 32-1/4" 13-1/4" 3-3/8" /2" 1" KHN110 11 110 95 102 89 7-3/8" 9-3/4" 11-1/8" 10-5/8" 14-5/8" 37-3/4" 33" 32-1/2" 14" 4-5/8" 1/2" 1" 198155 15.5 155 95 144 125 7-3/8" 9-3/4" 11-1/8" 10-5/8" 14-5/8" 37-3/4" 33" 32-1/2" 14" 4-5/8" 1/2" 1" KHN199 19.9 199.9 95 185 161 7-1/2" 10-1/2" 11-1/8" 11-5/8" 15-3/8" 38" 33" 32-3/4" 14" 4-5/8" 1/2" 1-1/4" KHN285 28.5 285 95 264 229 7-1/2" 10-1/2" 11-1/8" 11-5/8" 15-3/8" 38" 33" 32-3/4" 14" 4-5/8" 1/2" 1-1/4" >Smart System Digital Operating Control >Access to BMS Settings through Graphic LCD Display >ENERGY STAR Most Efficient Product Multi-Color Graphic LCD Display w/Navigation Dial, >High-Voltage Terminal Strip >95%DOE AFUE Efficiency Soft Keys and Loch-N-LinkTM USB programming 120 VAC/60 Hertz/1 Phase Power Supply >Modulating Burner with up to 10:1 Tu >Three Boiler Setpoint Temperature Inputs Three Sets of Pump Contacts Direct Spark Ignition - Plus Domestic Hot Water Prioritization >Low-Voltage Terminal Strip Low NOx Operation >Built-in Cascading Sequencer for up to 8 Boilers, DHW Recirculation Pump Start/Stop >ASME Stainless _, with Cascade Redundancy 24 VAC Device Relay 30 PSI ASME Rel Multiple Size Boiler Cascade Proving Switch Contacts >Vertical&Horizo Lead Lag Flow Switch Contacts PVC,CPVC,Polypropylene:T yen r_ Efficiency Optimization Alarm on Any Failure Contacts >Smart System Control Front End Loading Capability Runtime Contacts >Condensate Trap >Outdoor Reset Control with Outdoor Air Sensor DHW Thermostat Contacts • Programmable for Three Reset Temperature Inputs 3 Space Heat Thermostat Contacts >Other Features >Programmable System EfficiencyOptimizers System Sensor Contacts Automatic Reset High Limit g Y P Adjustable High Limit w/Manual'. SH Night Setback DHW Tank Sensor Contacts Boiler Circulating Pump DHW Night Setback Outdoor Air Sensor Contacts g Zero Clearances to Combustible Anti-Cycling Cascade Contacts Y g 12-Year Limited Warranty(See W Outdoor Air Reset Curve 0-10 VDC BMS External Control Contact Ramp Delay 0-10 VDC Boiler Rate Output Contacts • Modulation Factor Control 0-10 VDC Variable Speed System Pump Signal Input • Boost Temperature&Time 0-10 VDC Signal to Control Variable Speed Boiler Pump Modbus Contacts CON X•US >Four Pump Control Modbus Co• .. - System Pump with Parameter for Continuous Operation >Time Clock BACnet MSTP Boiler Pump with Variable Speed Control >Data Logging Flow Switch Domestic Hot Water Pump Hours Running,Space Heating Low-Water Cutoff '- Domestic Hot Water Recirculation Hours Running,Domestic Hot Water Alarm Bell >Domestic Hot Water Prioritization Ignition Attempts Concentric Vent , DHW tank piped with priority in the boiler loop Last 10 Lockouts SMART SYSTEM'PC Softwa- DHW tank piped as a zone in the system with the pumps >Maintenance Reminder Condensate Neutralization. controlled by the SMART SYSTEM Custom Maintenance Reminder with BMS Gateway to LON or' DHW Modulation Limiting Contractor Contact Information Multi-Temperature Lo. Separately Adjustable Space Heat/DHW Switching Times Installer Ability to De-activate Service Reminder Sidewall Vent Te!• >Building Management System Integration _ >Low-Water Flow Safety Control&Indication Wireless Outdoo 0-10 VDC Input to Control Modulation or - 0-10 VDC Modulation Rate Output • Lochinvar,LLC 300 Maddox Simpson,„,..,,�,y ost Efficient OE S,eN -7k Lebanon,Tennessee 37090Lochinvar P:615.889.8900/F:615.547.1000 _ .'144 016 �, CERTIFIED:). CERT. Eo _�I ■■■ ENEFGV STAfl nergY=tar.gov F.RO KHN-02 PDP-10M-01/16 Printed in U.S.A.©Lochinvar,LLC iPhone and iPod touch are trademarks of Apple Inc.,registered in the U.S.and other countries. Android and Google are trademarks of Google Inc.,registered in the U.S.and other countries. App store is a service mark of Apple Inc.Google Play is a service mark of Google Inc.