HomeMy WebLinkAboutDRB16-0246_A0.00 BDR_1482336015.pdf 354 BEAVER DAM ROAD RESIDENCES VAIL5 COL RAD N g MATERIAL SYMBOLS: ABBREVIATIONS: GENERAL NOTES: DRAWING INDEX: GENERAL AND SITE ffA A0.00 COVER EARTH rz- PLYWOOD ABV ABOVE L LENGTH o p L AFF ABOVE FINISHED FLOOR LDT LIGHT AND DRAPERY TROUGH Ol DO NOT SCALE DRAWINGS TOPOGRAPHIC SURVEY :` 0 AP ACCESS PANEL LT LIGHT TROUGH E r--6Y-c-6Y-;6Y-1 POROUS FILL/DRAINAGE iFFINISH WOOD AC ACOUSTICAL LTL LINTEL 02 VERIFY ALL DIMENSIONS, CONDITIONS AND UTILITY LOCATIONS ON L1 EXISTING SITE PLAN n THE JOB SITE PRIOR TO BEGINNING ANY WORK OR ORDERING N��c�- c�- ADD ADDENDUM LVR LOUVER ADJ ADJACENT MH MANHOLE ANY MATERIALS. nOTIFY ARCHITECT OF ANY CONFLICTS OR L2 PROPOSED SITE PLAN ALT ALTERNATE MFR MANUFACTURE (ER) DISCREPANCIES IN THE DOCUMENTS IMMEDIATELY. L3 LANDSCAPE VIEW PLAN ////// ALUM ALUMINUM MO MASONRY OPENING /��i�jji��i/ STONE MASONRY WOOD-ROUGH 03 AREAS OF CONFLICTS OR DISCREPANCIES MUST BE FULLY ARCH ARCHITECT (URAL) MTL METAL RESOLVED WITH WRITTEN APPROVAL FROM THE ARCHITECT BEFORE L4 LANDSCAPE PLANTING PLAN �, BSMT BASEMENT MAX MAXIMUM CONSTRUCTION CONTINUES IN THOSE AREAS. �IN CI BRG BEARING MECH MECHANIC (AL) L5 LANDSCAPE PLANTING DETAILS BVL BEVELED MC MEDICINE CABINET Y[ o STRUCTURAL CONCRETE BLOCKING 04 PLAN DIMENSIONS ARE TO FACE OF STUD OR FACE OF CONCRETE, BIT BITUMINUOUS MEM MEMBRANE UNLESS OTHERWISE NOTED.SECTION AND ELEVATION DIMENSIONS AREa N BLK BLOCK M METER (S) TO TOP OF CONCRETE,TOP OF PLYWOOD, OR TOP OF WALL PLATES OR BLKG BLOCKING MM MILLIMETER (S) BEAMS UNLESS OTHERWISE NOTED. DRAWING INDEX: ARCHITECTURAL CONCRETE MASONRY UNIT GYPSUM BOARD BOT BOTTOM MIN MINIMUM v o ETI BLDG BUILDING MIR MIRROR 05 PROVIDE ALL NECESSARY BLOCKING IN STUD WALLS AND CEILINGS. A2.00 GRFA CALCULATIONSof U m CPT CARPET (ED) MISC MISCELLANEOUS LOCATIONS INCLUDE BUT ARE NOT LIMITED TO CEILING AND WALL CO)� 4 ' ' j CSMT CASEMENT MULL MULLION MOUNTED FIXTURES, TOILETS,TOILET ACCESSORIES, CABINETRY, A2.01 LOWER LEVEL PLAN BATT INSULATION C CAULK (ING) NAT NATURAL COUNTERTOPS, SHELVES AND CLOSET RODS. CLG CEILING NR NOISE REDUCTION A2.02 MAIN LEVEL PLAN CT CERAMIC TILE NOM NOMINAL 06 ED DENOTES DOORS. REFER TO FLOOR PLANS FOR LOCATIONS. REFER • CLR CLEAR NIC NOT IN CONTRACT TO DOOR SCHEDULE FOR DOOR TYPES. A2.03 UPPER LEVEL PLAN RIGID INSULATION COL COLUMN NTS NOT TO SCALE /� CONC CONCRETE OPG OPENING 07 O DENOTES WINDOWS. REFER TO WINDOWS AND FLOOR PLANS FOR A2.04 ROOF PLAN CMU CONCRETE MASONRY UNIT OPP OPPOSITE LOCATIONS. REFER TO WINDOW SCHEDULE FOR WINDOW TYPES. (In CONST CONSTRUCTION OPH OPPOSITE HAND A3.O1 BUILDING ELEVATION STEEL/METAL AS NOTED CONT CONTINUOUS OH OVERHEAD 1/ // CJT CONTROL JOINT PR PAIR A3.02 BUILDING ELEVATION CPR COPPER PK PARKING 08 COORDINATE ALL ELECTRICAL AND MECHANICAL FIXTURES TO FITla CUST CUSTOM PVMT PAVEMENT WITHIN CEILING, FLOOR AND WALLS SPACES. VERIFY LOCATIONS WITH A3.03 BUILDING ELEVATION IIIIIIIIIIIIIIIIIIIIIIIIIII CARPET DT DRAPERY TROUGH PL PLASTIC LAMINATE ARCHITECT. IIIIIIII DTL DETAIL PT POINT A3.04 BUILDING ELEVATION DIM DIMENSION PSF POUNDS PER SQUARE FOOT 09 IN THE EVENT THAT ADDITIONAL DETAILS OR GUIDANCE IS NEEDED BY A3.05 BUILDING ELEVATIONa DR DOOR PSI POUNDS PER SQUARE INCH THE CONTRACTOR FOR CONSTRUCTION OF ANY ASPECTS OF THIS DRW DRAWING PL PROPERTY LINE PROJECT, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE A3.06 BUILDING ELEVATION DF DRINKING FOUNTAIN QT QUARRY TILE ARCHITECT. ELEC ELECTRIC (AL) REF REFERENCE A3.07 BUILDING ELEVATION 1 1 EL ELEVATION (S) REF REFRIGERATOR 10 THE CONTRACTOR SHALL BE RESPONSIBLE FOR SATISFYING ALL A3.08 BUILDING ELEVATION A4.00 A4.00 ELEV ELEVATOR REIN REINFORCE (D), (ING) APPLICABLE CODES AND OBTAINING ALL PERMITS AND REQUIRED EQ EQUAL REQ REQUIRED EXH EXHAUST RES RESILIENT APPROVALS.THIS PROJECT IS GOVERNED BY THE INTERNATIONAL EXTG EXISTING REV REVISION (D), (ING) BUILDING CODE, 2003 EDITION. CODE COMPLIANCE ISla BUILDING SECTION REFERENCE ELEVATION REFERENCE EXT EXTERIOR REV REVERSE MANDATORY.THE CONSTRUCTION DOCUMENTS SHALL NOT PERMIT FOC FACE OF CONCRETE RH RIGHT HAND WORK THAT DOES NOT CONFORM TO ALL RELEVANT CODES FOF FACE OF FINISH R RISER INCLUDING IBC AND ALL LOCAL AND REGIONAL CODES. 0 FOM FACE OF MASONRY R&S ROD AND SHELF FOS FACE OF STUDS RD ROOF DRAIN 11 THE CONTRACTOR SHALL FIELD COORDINATE AND OBTAIN 1 ( 1 FIN FINISH (ED) RDT RECESSED DRAPERY TRACK APPROVAL FROM THE ARCHITECT & ENGINEER BEFORE ANY A4.00 A400 FFE FINISHED FLOOR ELEVATION RFG ROOFING CUTTING, NOTCHING OR DRILLING OF ANY CAST-IN-PLACE `/ FE FIRE EXTINGUISHER RM ROOM CONCRETE, STEEL FRAMING, OR ANY OTHER STRUCTURAL ELEMENTS FDC FIRE DEPARTMENT CONNECTION RO ROUGH OPENING WHICH MAY AFFECT THE STRUCTURAL INTEGRITY OF THE BUILDING. FHC FIRE HOSE CONNECTION R/S ROUGH SAWNfin DETAIL REFERENCE DETAIL REFERENCE FEC FIRE EXTINGUISHER CABINET S SEALANT (EXTERIOR) FP FIREPLACE SHTG SHEATHING FPS FIREPROOFING,SPRAYED SHH SHOWER HEAD 12 THE CONTRACTOR SHALL VERIFY ALL EXISTING GRADES AND STAKE c MAIN 1 FLG FLASHING SHC SHOWER CONTROLS OUT THE BUILDING FOOTPRINT FOR OWNER AND ARCHITECT M la Q 100'-0" A FLR FLOOR (ING) SM SHEET METAL APPROVAL PRIOR TO BEGINNING ANY SITE WORK. FD FLOOR DRAIN SIM SIMILAR C'i ict FTG FOOTING SC SOLID CORE 13 IT IS THE INTENT AND MEANING OF THESE DOCUMENTS THAT THE Z CC 5 HEIGHT REFERENCE FND FOUNDATION SPEC SPECIFICATON (S) CONTRACTOR AND EACH SUBCONTRACTOR PROVIDE ALL LABOR, J 0 SECTION REFERENCE FBO FURNISHED BY OTHERS SQ SQUARE MATERIALS, TRANSPORTATION,SUPPLIES, EQUIPMENT, ETC.TO OBTAIN FPHB FREEZE PROOF HOSE BIB STD STANDARD A COMPLETE JOB WITHIN THE RECOGNIZED STANDARDS OF THE O FUR FURRED (ING) ST STAIN INDUSTRY. W C.) GA GAGE, GAUGE STL STEEL .. ROOM NAME GALV GALVANIZED SD STORM DRAIN J GC GENERAL CONTRACT (OR) STR STRUCTURAL 14 ALL BUILDINGS TO FIT WITHIN PROPERTY LINES WITHOUT CROSSING Q r /� GL GLASS, GLAZING TEL TELEPHONE EASEMENTS OR SETBACKS. NOTIFY ARCHITECT OF ANY DISCREPANCIES. A ; 1 GYP GYPSUM BOARD TV TELEVISION 5 REVISION REFERENCE ROOM NAME HB HOSE BIB THR THRESHOLD 15 PROVIDE ACCESS PANEL TO MOTOR FOR ALL WHIRLPOOL-TYPE TUBS. HDW HARDWARE T&G TONGUE AND GROOVE COORDINATE ACCESS LOCATIONS WITH INTERIOR DESIGNER AND J HDR HEADER TOS TOP OF SLAB ARCHITECT TO PROVIDE INCONSPICUOUS LOCATION. a O HTG HEATING TOS TOP OF STEEL HVAC HEATING/VENTILATING/AC TOW TOP OF WALL GRID W11 HT HEIGHT TB TOWEL BAR HC HOLLOW CORE TR TRANSOM a HM HOLLOW METAL T TREAD GRID BUBBLE WALL TYPE REFERENCE HOR HORIZONTAL TYP TYPICAL C) HWH HOT WATER HEATER UNO UNLESS NOTED OTHERWISE 0 CC INCL INCLUDE (D), (ING) VB VAPOR BARRIER mCC ; 1 ID INSIDE DIAMETER VIF VERIFY IN FIELD PROJ ECT CODE SUMMARY: IBC INSTALLED BY CONTRACTOR VERT VERTICAL Q n 'BO INSTALLED BY OWNER VCT VINYL COMPOSITION O� Wm 4 A8 2 11 INS INSULATE (D), (ION) WC WATER CLOSET Code: INT INTERIOR WP WATER PROOFING International Residential Code 2015 3 JC JANITOR'S CLOSET WWF WELDED WIRE FABRIC Occupancy: One-Family DwellingA I a 3 KIT KITCHEN W WIDTH, WIDE M WDW WINDOW Separations: LAM LAMINATE (D) INTERIOR ELEVATION REFERENCE WINDOW TAG 1 Hour (residence/garage) LAV LAVATORY WO WITHOUT LH LEFT HAND WD WOOD 1 Hour (residence/mechanical) Special Attributes: ® Addressable Fire Alarm System STN=T=TILE Automatic Sprinkler System DOOR TAG MATERIAL BREAK 4 w en 11 in cwil ISSUED FOR: DATE: SCHEMATIC DESIGN 3.3.16 PEC APPEAL 5.23.16 CONCEPTUAL REVIEW 6.18.16 COPY RIGHT RESERVATION The drawings, specifications and other documents prepared by the Architect (Michael Suman Architect, LLC) for this project are instruments of the Architect's service for use solely with respect to this Project and, unless otherwise provided in writing, the Architect shall be deemed the sole and exclusive author of these documents and shall retain,without limitation, all common law, statutory and other reversed rights, including the copyright hereof. No person, whether having come rightly into possession hereof or otherwise, 2016 MICHAEL SUMAN ARCHITECT,LLC. shall employ these documents on any other project, nor C' ALL RIGHTS RESERVED. for additions to this Project nor for the completion of this SCALE: 1/4"=1'-0" Project by others, unless with the prior express written consent of the Architect and upon appropriate DRAWN: MDS compensation to the Architect in an amount and kind satisfactory to the Architect. The Architect expressly PROJECT#: 1506 claims all proprietary rights in the material which is issued SHEET TITLE: COVER SHEET in confidence for design and/or construction purposes of this Project as noted. These materials may not be copied, modified, nor employed in any way without the specific prior written consent and permission of the Architect. ©2016 Michael Suman Architect, LLC. All rights reserved.