HomeMy WebLinkAboutB16-0418 cut sheets Engineering S
Triangle ) g g ubm�ttal
Tube ACV Prestige Solo 110
ACVMax Control System
• Graphical display with 6 navigation buttons
• EZ Setup allows quick and easy boiler settings adjust-
ment
' • • Presets allow quick configuration of 4 circulator out-
puts
i
i(ny
• Each circulator output is fully configurable for cus-
c <,,yt• us tom applications
• Outdoor temperature reset to maximize efficiency
A. • Accepts two space heating call inputs with indepen-
SM dent outdoor reset curves
E • Simultaneously heat dual temperature heating sys-
" tems with built-in mixing valve control
til I • Domestic hot water priority with optional time-out
• Integrated cascade control for up to 6 Prestige boil-
ers
• 0-10 VDC Modulation input
Prestige Solo Features • Modbus building management system(BMS)inter-
face,LonWorks®and BACnet®interface optional
• Light weight construction for wall mounting • Warm weather shutdown option
• Approved for zero clearance to combustibles • Optional boiler freeze protection
• 2"PVC,CPVC, PP venting up to 45 equivalent feet • Logging function records sensor readings for sys-
• 3" PVC. CPVC, PP, or AL29-4C venting up to 100 tern optimization and troubleshooting
equivalent feet • Describes lockouts in plain english and suggests
• Limited 5 year warranty on parts,except igniter solutions while storing last 8 errors
• Limited 10 year warranty on heat exchanger Standard Equipment
Approvals • Stainless steel premix burner
• 95%AFUE Efficiency • Direct spark ignition with variable speed blower
• ENERGY STAR Qualified • Full modulation with turndown ratio of 5.5:1
•
• ANSI Z21.13 and CSA 4.9 Boiler Standards Aufiomaticairvent
Compliance • ASME 30 PSI pressure relief valve
•
• ASME Boiler Certification —ASME"H"Stamp Integrated pressure and temperature gauge
•
• Low NOx operation exceeding SCAQMD 2012 regu Outdoor temperature sensor
lations • Automatic low water cutoff feature with early warn-
ing
Stainless Steel Fire Tube Heat Exchanger • High temperature limit safety control
• Terminal block for circulator output
• 439 Stainless Steel with titanium heat exchanger • Low voltage terminal strip with removable jumpers
construction for corrosion resistance for manual or automatic reset limits
• Low pressure drop minimizes circulator size • Swing out control for easy access and servicing
• High water content provides stable temperature • Alarm and flame status contacts
control • Polypropylene condensate pan and internal flue
• Self cleaning flue ways reduce maintenance pipe
• Suitable for use with propylene glycol up to 50% • Polypropylene vent/air connections with test ports
concentration
Project/Location: Date:
Consulting Engineer/Architect:
Mechanical Contractor:
Dale:7/1/2016 1 2016.7 Prestige ACVMax Solo 110 Submittal
1
Boiler Dimensions Letter Connection Dimension
in [moo _
3/4"NPSC 16-5/8'
Front View Side View A Pressure Relief [423]
A Valve
B i B 3"Combustion 15-13/16" —
!. c [ J p. Air Inlet [402]
A >7.•
1_,18..-1:.:-_ 0------a, },..o.,.!, C 3"Vent Outlet 8-13/16"
�.. . _ f k_ [224]
I 1I
t-`—; -I D 1"NPT Boiler 2-7/8" -
}>� Return [73]
}i E 1/2"NPT Gas 5.7/8"
l.,`t"+' .I-• - -I.: °--
:-I
-" r ••°-g Connection [150]
-1 i '. :
S. , 1. F r NPT Boiler 16-7/16"
! f '1'41 I Supply [418]
Li : _ •• •, , ' G Boiler Width 19-3/4"
ki 1 I1 [502]
H '{ ' �7 � j H Boiler Height 3[928]6"
3/4"NPSC
!.• 1 �e�--' _ iT-324 I Pressure Relief 111/4"
1 _ L-_--2
Valve [286]
3"Combustion 5.9/16"
,:: 1r '� J Air Inlet&
I •` _ • i > it -}r
' 3"Vent Outlet [141]
0 it 0
L •- ,J K 1/2"NPT Gas 4"
s1.D. � Connection [102]
~�' K
F • L ' ' L 1"NPT Boiler 13-7/16"
G
•
M Return&Supply [341]
M Boiler Depth 17-5/16"
[440]
Boiler Specifications
Input Net
Model Fuel Modulation AFUE DOE Heating AHRI Boiler Water Shipping Weight
(MBH) Capacity(MBH) (MBH) Volume(gal) Lbs
PA 110 Paopaner 2.1
20-110 95% 102 89 103
Pressure Drop Curve vs Grundfos UPS 15-58-FC
16 —
14
3 10 i /
a f
o s i —
o
4
0 2 -n Solo 110
— _ • •Grundfos t1PS15.58F/FC-Spd1
0 Grundlos UPS15.58F/FC-Spd 2
4 5 6 7 8 9 10 11 12 —tITGrundlos UP515-58F/FC•Spd3
Flow Rate(GPM) - solo 110
2