Loading...
HomeMy WebLinkAboutA16-0075_FA1_1482436816.pdfP P c C C 30' P P P 14'-111 8" P/CO P/CO C C C C C FAJ FAJ FAJ FAJ FAJ FAJ FAJ FAJ FAJ FAJ FAJ 3:1:54 3:1:55 3:1:56 3:1:59 3:1:60 3:1:61 3:1:62 E NC SLC IN + SLC OUT + SLC PROG + Addressable Circuit-Typical Equipment List - Fire Alarm System Quant. Symbol Device Manufacturer Part # 5 XX 2 4 XX 7 XX 1, 0 XX XX XX XX XX 1 XX XX XX XX XX XX XX XX 11 Symbol Smoke Detector Gamewell/FCI ASD-PL2F, B210LP Heat Detector ROR Gamewell/FCI ATD-RL2F Fire/CO Detector Pull Station Gamewell/FCI Gamewell/FCI MCS-COF MS-7AF Strobe Spkr Multi tap System Sensor System Sensor SCW: Ceiling(c), SW: Wall AH-24-W Spkr Strobe MC cd Horn Strobe Ext. System Sensor System Sensor SPSCW P2RK Remote Indicator Flow Switch Tamper Switch Door Holder Duct Detector Control Panel Annunciator Fire Force 8 Gamewell/FCI Gamewell/FCI Gamewell/FCI Gamewell/FCI Gamewell Gamewell/FCI Gamewell/FCI Gamewell/FCI RA400Z AMM-2F AMM-2F DH-FC1 ADPF E3 NGA, LCD SLP-E3 FF8 smoke+sounder base linear beam det. Low Air Switch Aux. Power Supply Monitor Module Address. Relay Gamewell/FCI Gamewell/FCI Gamewell/FCI Gamewell/FCI Gamewell/FCI Gamewell/FCI ASD-PL2F, B200SR-LF ABD-RT2F AMM-2F PM-9 AMM-2F AOM-2RF P P E P FACP FSA P SB BT AUX PWR Acme Alarm Company Venture Sports R/F NAC EXP AOM 2RF 1:2:81 Loop Number Device Number Node Number AMM mon C P/CO FAJ Fire Alarm Junction Box Varies Varies Acme Alarm Company Speaker-Strobe Wiring Typical WIRING CAB APPROVED BY: DRAWN BY: 5-11-07 DISK: CHECKED BY: DATE: SCALE: 14 awg 2cond shielded FPLR Spkr Contacts Strobe Contacts Spkr Contacts Strobe Contacts 14 awg 2cond FPLR To 3:1:63 in Hallway 30 30 30 30 30 30 30 15 EOL N2 EOL N1 P P P P 3:1:64 3:1:65 3:1:66 3:1:67 Scale Project Date Sheet Revision/Issue Project Name and Address Firm Name and Address No. Date General Notes Venture Sports Vail Cascade Terrace Bldg Vail, CO 81657 Prepared by: C l i n t B a r t e l s N I CE T # 1 0 4 5 1 9 NORTH 1/8"=1' The SLC junction boxes are shown on the south side of the wall for illustration purposes only. The junction boxes actually reside on the north side of the wall. Notes Verify the end of line for the speaker circuit and the strobe circuit. Verify voltage and wattage taps for speakers. The number of smoke detectors is the same. Spacing is adjusted to meet code for CO and Starwood requirements. The number of Speaker-strobes has been decreased by three. Mount Pull stations at 48" AFF. Conduit required below ceiling height. approved. Vail Fire & Emergency Services 12/22/16