HomeMy WebLinkAboutA16-0015 FA-0.00 ° cir1/4 4. LEGEND : ,.,.:0ld'i/y i Vail Fire&Emergency Services � + st �1�: 03/22/16 SYMBOL DEVICE MANUFACTURER PART MOUNTING ^` v�. O; MANUFACTURER/PART# °i,3 352331 ero • FACP Honeywell ..- .O. t,er �?:74.`:4 i � 'N,. GORDON RESIDENCE Vista-128BPT r . ; ; Ademco Vista 128 FACP Fire Alarm Control Panel w/7AH Batteries Mount on wall in manufacturer backbox • ;�e7, -.,:-' ;,�„ Standby .. - Number of Current Total Current KP Device Type Devices (Amps) Amps} LCD Keypad/Annunciator Honeywell 6160 Mount on wall in manufacturer backbox Main FACP CPU 1 X 0.032 = 0.032 4193SN Serial Interface 3 X 0.00015 - = 0.00045 Combination Smoke & COSMOD4W Module 3 X 0.052 = 0.156 Heat Detector w/Sounder System Sensor i3 series 4WTA-B 4" square box i3 Smoke Detector 6 X 0.0005 = 0.003 i4 Smoke/CO Detector 11 X 0.0005 = 0.0055 Combination Smoke and 6160 Keypad 2 X 0.04 = 0.08 0co CO Detector w/Sounder System Sensor i4 series COSMO-4W 4" square box SUM COLUMN FOR STANDBY LOAD 0.27695 = AMPS O System Sensor 5601P Heat Detector w/4193SN Addressable module 4" square box Alarm Load - Number of Current Total Current Device Type Devices (Amps) (Amps) © Cosmo Interface Module COSMOD4W Main FACP CPU 1 X 0.032 = 0.032 4193SN Serial Interface 3 X 0.00015 = 0.00045 COSMOD4W Module 3 X 0.075 = 0.225 KB Knox Box i3 Smoke Detector 6 X 0.035 = 0.21 - i4 Smoke/CO Detector 11 X 0.04 - = 0.44 6160 Keypad 2 X 0.1 = 0.2 LV Horn/Strobe, weatherproof System Sensor P2RK Weatherproof backbox Outside Horn/Strobe 1 X 0.195 = 0.195 z _o SUM COLUMN FOR ALARM LOAD 1.30245 = AMPS a Standby Load Required Standby Time in Hours E Current (Amps) GENERAL NOTES: w 0.27695 X 24 = 6.65 0 Alarm Load Required Alarm Time in Hours 1 . ALL EQUIPMENT IS TO BE INSTALLED AND TESTED IN o Current (Amps) [15 MINUTES) ACCORDANCE WITH MANUFACTURER STANDARDS, FIRE > 1.30245 X 0.25 = 0.33 w Add Standby and Alarm Load for Required DEPARTMENT REQUIREMENTS AND NFPA 72. Ampere Hour Battery 6.97 2. REFER TO MANUFACTURERS DATA SHEETS AND Multiply by the Derating Factor of 1.2 INSTALLATION INSTRUCTIONS FOR FURTHER INFORMATION Total Ampere Hours Required = 5.37 REGARDING PRODUCT INSTALLATION, WIRING DIAGRAMS, Batteries Provided: 12AH Minimum PROGRAMMING AND DEVICE OPERATION. Q a ZONE LIST O Approved for install - z ZONE # DESCRIPTION 1 SPRINKLER WATERFLOW N 2 SPRINKLER TAMPER CO 3 LOWER LEVEL CO DETECTION 0 0 4 LOWER LEVEL SMOKE DETECTION 0 Q 5 MAIN LEVEL CO DETECTION 6 MAIN LEVEL SMOKE DETECTION t" rri O 7 UPPER LEVEL CO DETECTION J '- 0 o Z L9 8 UPPER LEVEL SMOKE DETECTION SEQUENCE OF z0 Q o •• o O C 9 GARAGE HEAT DETECTOR N J z > 0 E 10 ,SYSTEM TROUBLE OPERATIONS: w Z z z `-' z o c� o o cn o z o Co . cn m_ cn r,, N Q N Q uJ o � - m Z x L.o CC N H > H J H ^ , O 0 a o0 o' N wN CCI (/) z w moo co _ = C9 0_ o O (� O O U O ccoo x zH gad N � � � � m (r) fl' - c 3 Mo � o � o V) o 0 O � (n Q DEVICE Ct I- Q QD No No No Qo Q� z - z • z � DESCRIPTION co I vct go go go ED Up "I�r�� < < H HH � � HH Qcn Q = .� 8�E c9 z SMOKE DETECTOR X X X H 0 z 0 HEAT DETECTOR X X X CARBON MONOXIDE DETECTOR X X X SPRINKLER WATERFLOW SWITCH X X X X SPRINKLER TAMPER SWITCH X X CO M . CID POWER LOSS, OPEN CIRCUIT, GROUND FAULT X X 1- a7 0) PROJECT INFORMATION : r w 0, GORDO \ RESIDE\ CE 0 v) VAIL, COLORADO < 0 w FIRE ALARM SYSTEM 0 Z z D D= 4-WIRE DATA/POWER, 4-#16AWG (2 PAIR) J 0 Q X = 2-WIRE DATA, 2-#16AWG EOL EOL AHJ: VAIL FIRE & EMERGENCY SERVICES O Z © APPLICABLE CODES: 2015 IBC, 2015 IFC, 2013 NFPA 72 0 0 N = 2-WIRE SOUNDER CIRCUIT, 2-#18AWGJ = Z = 2-WIRE DATA CIRCUIT, 2-#16AWG D D FULLY SPRINKLERED _ J Q KP = KEYPAD CIRCUITING, 4-#18AWG FIRE ALARM SYSTEM FOR SINGLE FAMILY HOME. SYSTEM INCLUDES NEW w > W O RISER NOTES: ;CO co ADDRESSABLE VISTA 128 FIRE ALARM CONTROL PANEL. SMOKE 0® J 0 D CO DETECTORS WILL BE INSTALLED IN SLEEPING ROOMS AND AREAS OUTSIDE Z = W 1. REFER TO VISTA INSTALLATION MANUAL FOR D D OF SLEEPING ROOMS. INTEGRAL CARBON MONOXIDE DETECTORS ARE w 0 I- 0 MORE INFORMATION. 2. WIRE SIZE MAY BE VARIED, PROVIDED IT MEETS L,N L,N PROVIDED WITHIN 15 OF FUEL BURNING APPLIANCES. HEAT DETECTORS MANUFACTURERS SPECIFICATIONS. c D WILL BE INSTALLED IN THE GARAGE. SOUNDERS ARE INTEGRAL TO U) 3. VERIFY WIRING OF SYSTEM SENSOR COSMOD4W (TYP) (TYP) DETECTORS. A KNOX BOX WILL BE MOUNTED ON THE OUTSIDE OF THE w w 0 m PRIOR TO INSTALLATION. WIRING DIAGRAM IS ® HOME. THE SPRINKLER SYSTEM IS MONITORED BY THE FIRE ALARM 0 U D INCLUDED SUBMITTAL BOOKS. w SYSTEM. Z - Q 120VAC DEDICATED POWER VISTA 128FPB 0 cL cL Z CONTROL PANEL Z FLOW SWITCH 0 CO H 0 Z Z TAMPER SWITCH 0 COMO w TELEPHONE LINE - FIRE TELEPHONE LINE - SECURITY BELL N WP FIRE PROTECTION ENGINEER: 0 co BELL U D OUTPUT EOLR DEBORAH SHANER, P.E., SHANER LIFE SAFETY PO BOX 1073, FRISCO, CO 80443 SHEET DESCRIPTION: RISER DIAGRAM DAOCOM UTPUT KP KEYPAD KEYPAD PHONE: 970-409-9082 FIRE ALARM PLAN FAX: 970-797- 1898 DRAWN BY: DATE: DLS 3/2/16 SHEET#: FA-0.00