HomeMy WebLinkAboutA16-0073 cut sheets.pdf Honeywell VISTA-20P VISTA° CONTROL PANEL grao _ reLt The high capacity, feature-rich VISTA-20P lets you deliver In addition, the VISTA-20P, used with an AlarmNet°Internet or more value to your customers on each and every sale with 4G communicator can be installed in premises without TELCO up to 48 zones of protection, Internet uploading/downloading, lines. The panel's installation advantages, innovative end-user graphic keypad support and dual partitions. VISTA-20P gives benefits and robust system capacity make the value-priced you the ability to send alarm signals and upload/download via VISTA-20P an ideal choice for higher end installations. an Internet Protocol (IP), improving the speed at which information can be delivered to and from the control panel. FEATURES • IP alarm reporting and uploading/ • 16 output devices •Dynamic Signaling downloading capability for Internet and —Relays(Model 4204 Relay Modules, —Reduces redundant reporting to Intranet use via iGSMV4G, 7845i-ENT, or 4229 Expansion Module) the central station when multiple GSMV4G or GSMX4G • Four installer configurable zone reporting methods are used; i.e. •Supports four graphic types allows the installer to create digital dialer and AlarmNet radio touchscreen keypads custom zone types by assigning Valuable End-user Features all zone attributes •Wireless keys can be programmed •Viewable on system keypads: without using zones •Supports four wire and up to —Exit countdown 16 two-wire smokes —Time and date display* • Eight on-board hardwired zones —Works with Sentrol CleanMem" (15 when Zone Doubling —Event log" standard maintenance signal feature is used) •Auto keypad backlighting on entry -40 hardwire expansion zones • Multiple actions on output devices -40 wireless expansion zones depending on system state • Keyswitch arming —Turns lights off when system arms .Programmable macro buttons and •Two low current on-board —Turns the same light on when trigger outputs system disarms single button arming —Flashes same lights when system •Supports a variety of wireless remote • 100 Event Log viewable at system is in alarm controls for single-button operation keypads with time/date stamp • Built-in phone line cut monitor •User Scheduling •48 system user codes assignable to with programmable delay and —Latchkey reports to pagers either partition annunciation options p —Auto arm/disarm • Expandable to 48 total zones when —Display on system keypads —"User access"time windows used with hardwired and/or wireless —Trigger local sounders expansion modules —Trigger system bell •VIP Module allows system control from any touchtone phone •Two independent partitions plus a Security Dealer Features common partition •Automatic System Load Shed •Chime by zone —Global Arming from any —During extended AC power fail, •Fully compatible with Honeywell Total system keypad the system battery will be Connect" Remote Services —Go to function to view or operate disconnected to prevent irreversible Requires custom alpha keypad one partition from the other battery failure. Reduces service —Separate partition account numbers calls to replace batteries. VISTA-20P VISTA° CONTROL PANEL SPECIFICATIONS Electrical •GSMV4G Digital Cellular Communicator Agency Listings •Aux. power 12VDC,600mA maximum with Remote Service Capability ETL listing •Seven hour standby at 400mA aux. •GSMX4G Digital Cellular Communicator for • Residential Fire and Burglary: load with four amp hour battery VISTA Control Panels —Household Fire Warning System Units—ANSI/UL 985,2000/05/26 • 16.5VAC/25VA transformer •5881 ENL RF Receiver supports (5th edition)with revisions up to up to eight zones—60mA 2004/04/29 •Alarm output 12VDC,2.0 amps max. -For UL installations,combined aux.and •5881 ENM supports up to alarm output cannot exceed 700mA 16 zones 60mA Smoke Detectors •5881 ENH supports up to •Supports up to 16 two-wire smoke detectors Output Control 48 zones—60mA •Supports up to four relay boards •Supports four-wire smoke detectors 5883 Transceiver supports up to (up to 16 relays) 40 zones—80mA •Optional X-10 transformer/interface Communications (part no.4300)may be used to control Keypads •Communi Internet and Digital Cellular up to 16 X-10 receiving devices •6162 Custom Alpha Security Keypad Cammunicator with Remote Service —40mA/120mA Capability Zones •7845i-ENT Enterprise Internet •Eight hardwired zones •6162V Voice Custom Alpha Security Communicator 9 Keypad—60mA/190mA (15 with zone doubling) •GSMV4G Digital Cellular Communicator •Selectable response 10msec, •6162RF Custom Alpha Receiver/Security with Remote Service Capability Keypad—120mA/210mA 350msec,750msec •GSMX4G Digital Cellular Communicator for •Assignable to any partition •6152 Fixed-English Security Keypad VISTA Control Panels —40mA/70mA •20 selectable zone types plus four •6152V Voice Fixed-English Security •Touchtone or pulse configurable zone types Keypad—60mA/190mA •Formats supported •Programmable swinger suppression •6152RF/6152RFFR Fixed-English/French —ADEMCO®Contact ID Receiver/Security Keypad—80mA/105mA —ADEMCO 4+2 Express —ADEMCO low speed Expansion Devices •6152ZN/6152ZNFR Fixed-English/French —Sescoa/Radionics •4219—Eight hardwired zones—16mA Security Keypad with Hardwired Zone •3+1,4+1 and 4+2 reporting •4204—Up to four relays—15mA standby —35mA/80mA (each active relay draws an •6148 Fixed English LCD—30mA/55mA •Reporting capabilities additional 40mA) —Split •6280 Color Graphic Touchscreen —Dual •4229—Eight hardwired zones and two Keypad with Voice —Split/Dual—True dial tone detection relays—36mA(each active relay draws an additional 40mA) •Tuxedo Touch"(TUXW)Color Graphic • Low battery reports 11.2—11.6VDC Voice Touchscreen Security Keypad and •AC loss and restoral reporting supported Accessories Home/Business Controller(White) •iGSMV4G Internet and Digital •Tuxedo Touch with Integrated Wi-Fi® Cellular Communicator with (TUXWIFIW)Color Graphic Voice Remote Service Capability Touchscreen Security Keypad and Home/Business Controller with •7845i-ENT Enterprise Integrated Wi-Fi(White) Internet Communicator ORDERING VISTA-20P Control Panel VISTA-20PSIA Control Panel for CP-01 SIA Certifications For more information: www.honeywell.com/security Automation and Control Solutions Honeywell Security Products Americas Honeywell 2 Corporate Center Dr. Suite 100 Hone P.O. Box 9040 Melville, NY 11747 1.800.467.5875 LNISTA20PD/D December 2013 www.honeywell.com ©2013 Honeywell International Inc. SYSTEM �$ SENSOR Smoke Detectors with Sounder and Relay Option 7 System Sensor ir sounder and relay smoke detectors apply the guiding principles of installation ease, 3 intelligence,and instant inspection in a series of TM specialty conventional devices. Features Installation ease.Throughout the i3 series,installation is simple •85 dB sounder with its installer-friendly base and plug-in design.The base accommodates a broad range of back box and direct mounting •Form C relay options and provides ample space for pre-wiring the device.To Isolated thermal sensor complete the installation,the i3 detector plugs into its base with a • simple Stop-Drop'N Lock action. •Plug-in design(base included) Intelligence.To reduce the likelihood of nuisance alarms,all •In-line terminals i3 detectors are equipped with both drift compensation and •Flexible mounting options smoothing algorithms.These capabilities minimize both short-and •Stop-Drop'N Lock"attachment to the base long-term causes of nuisance alarms,such as RF interference and dust accumulation.When connected to the 2W-MOD2 loop test/ •Removable cover and chamber maintenance module or an i3 Ready' panel,2-wire i3 detectors can generate a remote maintenance signal when in a maintenance or •Remote maintenance signaling freeze trouble condition.To measure the sensitivity of any i3 detector, •Drift compensation and smoothing algorithms the SENS-RDR displays the reading,in terms of percent-per-foot •Simplified sensitivity measurement obscuration,within seconds. •Dual-color LEDs Instant inspection.i3 has red and green LEDs to simplify local status indication during power-up,standby,alarm,maintenance, and freeze trouble conditions.When in alarm,i3 sounder models generate an 85 dB temporal tone.If connected to the RRS-MOD reversing relay/synchronization module,all i3 sounders on the loop will activate when one detector is in alarm.The RRS-MOD also synchronizes i3 sounder output to ensure a clear audible signal. Agency Listings Should the application call for differentiating between a local and a general alarm,the i3 line offers an isolated thermal model,which (13 ® sO MEA MSFMETA initiates a local alarm when smoke is detected,and a general alarm LISTED APPROVED approved approved cC r. us when the thermal sensor is activated. i�11 3015195 7272-1653:164 372-02-E 2133 3180932 �j�Smoke Detector Specifications Electrical Specifications LED Modes Operating Voltage Nominal:12/24V non-polarized LED Mode Green LED Red LED Condition Duration 2-wire:8.5 V to 35 V Power up Blink every Blink every 10 Initial LED 80 seconds 4-wire:10 V to 35 V 10 seconds seconds status Maximum Ripple Voltage 30%of applied voltage(peak to peak) indication Standby Current 2-wire:50 pA maximum average Normal Blink every 5 off 4-wire:50 pA maximum average (standby) seconds Peak Standby Current 2-wire:100 pA Out of off Blink every 5 4-wire:n/a sensitivity seconds Maximum Alarm Current 2-wire:2WTR-B:130 mA limited by control Freeze off Blink every 10 panel trouble seconds 2WTA-B:130 mA** Alarm off Solid 4-wire:4VVTAB,4WTR 6:35 mA Power-Up Sequence for LED Indication 4WTAR-B,4WITAR-B:50 mA **Direct Power(Non-Reverse Polarity):130 Condition Duration mA limited by panel.Reverse Polarity Power: Initial LED 80 seconds 30 mA for the 2WTA-B in alarm;12 mA for all status other 2WTA-B units on the loop.Add 25 mA indication for the RRS-MOD reversing relay alarm current. Architect/Engineer Specifications Alarm Contact Ratings 2-wire:n/a Smoke detector shall be a System Sensor i3 Series model number , 4-wire:0.5 A @ 30 V AC/DC listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Form C Contact Ratings 2 A @ 30 V AC/DC Systems.The detector shall be a combination photoelectric/thermal Physical Specifications equipped with a sounder(model 2WTA-B,4WTA-B),a Form C relay(model 2VVTR-B),a combination sounder/relay(model 4WTAR-B),or an isolated Operating Temperature 32°F to 100°F(0°C to 37.8°C) thermal/sounder/relay(model 4WITAR-B).The detector shall include a Range mounting base for mounting to 31/2-inch and 4-inch octagonal,single-gang, Operating Humidity 0 to 95%RH non-condensing and 4-inch square back boxes with a plaster ring,or direct mount to the Range ceiling using drywall anchors.Wiring connections shall be made by means Thermal Sensor 135°F(57.2°C)fixed of SEMS screws.The detector shall allow pre-wiring of the base and the Freeze Trouble 41°F(5°C) head shall be a plug-in type.The detector shall have a nominal sensitivity Sensitivity 2.5%/ft.nominal of 2.5 percent per foot as measured in the UL smoke box.The detector shall be capable of automatically adjusting its sensitivity by means of drift Input Terminals 14-22 AWG compensation and smoothing algorithms.The detector shall provide dual- Dimensions(including 5.3 inches(134 mm)diameter,2.0 inches color LED indication that blinks to indicate power-up,normal standby,out of base) (51 mm)height sensitivity,alarm,and freeze trouble conditions.When used in conjunction Approximate Weight 7.1 oz(200 g) with the 2W-MOD2 module,2-wire models shall include a maintenance Sound Pressure Output 85 dBA(models 2WTA-B,4WTA-B,4WTAR-B, signal to indicate the need for maintenance at the alarm control panel and and 4WITAR-B only) shall provide a loop testing capability to verify the circuit without testing each Mounting 311/z inch octagonal back box,4-inch octagonal detector individually.When used in conjunction with the RRS-MOD module, back box,single gang back box,4-inch square all i3 sounder models on a loop shall sound when one sounder alarms,all shall back box with a plaster ring,direct mount to be synchronized,and all sounders may be silenced from the panel. ceiling Ordering Information Model Thermal Wiring Alarm Current Model Description 2WTA-B Yes 2-wire 130 mA max.limited by RRS-MOD Reversing relay/synchronization module control panel 2W-MOD2 2-wire loop test/maintenance module 2WTR-B Yes 2-wire 130 mA max.limited by SENS-RDR Sensitivity reader control panel RT Removal/replacement tool 4WTA-B Yes 4-wire 35 mA A77-AB2 Retrofit adapter bracket 4WTR-B Yes 4-wire 35 mA 4WTAR-B Yes 4-wire 50 mA 4WITAR-B Yes 4-wire 50 mA *--. SYSTEM 02009 System Sensor. 3825 Ohio Avenue•St.Charles,IL 60174 Product specifications subject to change without notice.Vsit systemsensor.com for �� SENSOR Phone:800-SENSOR2•Fax:630-377-6495 current product information,including the latest version of this data sheet. A05-0348-004.6/09•#2170 SYSTEM rif) �$ SENSOR' TM i4 Series Combination • CO/Photoelectric Smoke Detector Best-in-class carbon monoxide(CO)and smoke detection technology in a single, system-connected device. Features Integration:The i4 Series combines CO and smoke detection into one device, requiring less wiring and fewer back boxes than • Single device for CO and smoke detection that uses less wiring two separate devices.The i4 Series is compatible with i3(2WTA-B and fewer junction boxes or 4WTA-B),so an attractive CO monitoring solution can easily be • Compatible with a wide range of control panels with the use of the retrofitted into existing i3 installations.The i4 Series CO cell can be required i4 Interface Module. easily replaced at end-of-life, resulting in a much lower life cost than • Sends distinct smoke and CO signals to the panel having to replace the entire detector. • Sounds Temporal 3 for smoke and Temporal 4 for CO Installation ease:The i4 Series Combination CO/Smoke detector • Built-in 85dB sounder requires less wiring than two separate CO and smoke devices. • LEDs display both CO and smoke status Installers can pre-wire its plug-in base,while its large wire-entry port External IR LED provides extended range sensitivity testing and in-line terminals provide ample room for neatly routing wiring.The • base accommodates several back box options and also direct mounts • Versatile mounting allows for wall or ceiling placement using drywall anchors.The i4 head plugs into the base with a simple • Easily replaceable electrochemical CO cell with 6-year end-of-life Stop-Drop'N LockTM action.When the detector's CO cell reaches end- timer that signals the panel and chirps to alert the homeowner of-life,it can be easily replaced in the field without a tool. • RealTest®enables functional test using canned CO Intelligence:With the help of the module,the i4 Series transmits • Drift compensation and smoothing algorithms provide false distinct CO and smoke signals,allowing appropriate response alarm immunity from the central monitoring station. Intelligent features,such as drift • Compatible with SENS-RDR sensitivity tester compensation and smoothing algorithms, reduce nuisance alarms. • Full agency compliance with UL 268 and UL 2075 Instant inspection:The i4 Series LEDs enable instant inspection of detector status signaling normal/standby condition,alarm condition,maintenance/trouble condition or functional test mode. 2-wire devices allow loop testing via the EZ Walk feature where wiring can easily be verified by checking the LED status at each detector. Smoke sensitivity can be easily measured using the wireless SENS- RDR device.CO cell functionality can also be quickly validated in the field with canned CO per NFPA 720:2009 requirements using the Agency Listings detector's RealTest functionality. ,T U o 4, LISTED S268 1653:0227 i4 Series Combination CO/Smoke Detector Specifications Carbon monoxide(CO)/Smoke detector shall be a System Sensor model number COSMO-2W(2-Wire)/COSMO-4W(4-Wire)listed to UL 268 for Fire Protection Signaling Systems and to UL 2075 for Carbon Monoxide Gas Detection.The detector shall be photoelectric smoke sensing and electrochemical CO sensing and equipped with a sounder capable of Temp 3 and Temp 4 audible signals.The detector shall have nominal sensitivity of 2.5 percent per foot as measured in the UL smoke box.The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector's base shall be able to mount to a single-gang electrical box or direct(surface mount)to the wall or ceiling.Wiring connections shall be made by means of SEMS screws.The detector shall provide LED indication that blinks to indicate normal standby,smoke alarm,smoke maintenance,CO alarm,CO trouble/end-of-life.When the detector is in CO trouble condition,it shall send a trouble signal to the panel.The detector shall provide a means to test CO gas entry into the CO sensing cell.The detector shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry.The 2-wire model shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually.The detector shall have a replaceable CO cell that can be replaced at end of cell life. Electrical Specifications Operating Voltage(VDC): Nominal: 12/24;Minimum:8.5;Maximum:35 Maximum Standby Current: 50 pA Maximum Alarm Current: 2-Wire 50mA;4-Wire 40mA Audible Signal: 85 dBA Maximum Reverse Polarity Current: 20 mA Maximum Start-up Current: 200uA Maximum Start-up Capacitance: .10 pF Physical Specifications Dimension: Diameter:5.5 Depth:2.5"(includes base) Weight: 9.2 oz.(261 g) Operating Temperature Range: 0—50°C(32—122°F) Operating Humidity Range: 20-95%RH Storage Temperature Range: -10—70°C(14—158°F) Sensitivity: 2.5%/ft nominal Input Terminals: 14 to 22 AWG Mounting: Back boxes:3.5"and 4"Octagonal;Single-gang;4"Square;2 x 4",3.5"and 4"round ceiling. Direct mount to wall or ceiling. Operation Modes/LED Status Green Red Blue Sounder Alarm Smoke: Off On Off Temp 3 Alarm CO: Off Off On Temp 4 Alarm Smoke&CO: Off On On Temp 3 Power Up: Blink 5 sec. Blink 5 sec Blink 5 sec. Off Standby: Blink 5 sec. Off Off Off RealTest®Mode(CO): Off Off Blink 1 sec. Off After CO is Sprayed: Off Off On Temp 4 Smoke Maintenance: Off Blink 5 sec. Off Off CO Trouble: Off Off Blink 5 sec. Off End-of-Life: Off Off Blink 5 sec. Intermittent i4 Series Interface and Reversing Relay Module e e e The i4 Interface Module connects up to 12 detectors to a • •e wide range of control panels using only 2 to 3 zones. It • also interconnects the devices, so when one device alarms, they all sound. Features Integration:The i4 module allows up to 12 i4 Series or compatible • Easily integrates up to 12 compatible detectors to a wide range of i3 Series smoke detector models to be integrated into a fire alarm panel using only 2 to 3 zones:a smoke zone,a CO zone and an control panels optional trouble zone. Detectors sound Temp 3 for smoke and Temp • 2-wire module is compatible with COSMO-2W combination 4 for CO events.The i4 module can be used to alarm all sounders in detectors and 2WTA-B smoke detectors. compatible detectors for smoke and CO events.When one detector • 4-wire module is compatible with COSMO-4W combination detects smoke or CO and goes into alarm,all connected detectors detectors and 4WTA-B smoke detectors. alarm,offering the highest level of warning to the homeowner. • Sends distinct smoke and CO signals from i4 detectors to the panel Installation ease:The i4 Series Interface Module mounts to a • LED indication shows when a detector on the loop requires 411/16-inch square back box for quick and easy installation.Terminal cleaning or maintenance(2-wire detectors only) blocks with durable SEMS screws ensure a reliable connection. It • Initiates the EZ Walk loop test(2-wire detectors only) also has pre-drilled holes for easy mounting inside a metal enclosure • Module interconnects the sounders of all devices connected to it. Intelligence:The i4 Interface Module allows i4 and compatible i3 No RSS-MOD is required.Optional trigger inputs are provided to sound multiple modules. smoke detector models(2WTA-B and 4WTA-B)to communicate with any listed fire alarm control panel capable of utilizing this module. Instant inspection:The i4 Interface Module provides LED status indication for the loop,displaying normal operation,loop wiring fault, smoke events,smoke maintenance(2-wire only),CO events,and CO maintenance/end-of-life. Agency Listings ,T y� �G LISTED SHI 1653:0228 i4 Series Interface Module Specifications The i4 module shall be a System Sensor i4 Series model number COSMOD2W(2-wire)or COSMOD4W(4-wire)listed to UL 864 and UL 985 for Control Units for Fire Protection Signaling Systems.The module shall include provisions for mounting to 4-inch square back box. Wiring connections shall be made by means of SEMS screws.The module shall provide 4 LED indicators that blink or illuminate to indicate communication status,maintenance alert,alarm or freeze trouble conditions,and EZ Walk loop test mode(2-wire module only).The module shall allow communication to i4 Series and i3 Series detectors with sounders with any UL 864-and UL 985-listed fire alarm control panel capable of utilizing this module.The 2-wire module shall offer provisions for Style D/Class A wiring on IDC loops and shall provide a loop testing capability(EZ Walk)to verify the initiating loop wiring. Electrical Specifications Module Operating Voltage(VDC): Nom.: 12/24;Min.:8.5(2-wire), 10(4-wire,power limited);Max.:35 VDC(power limited) Standby Current: 2-Wire:61mA(max.),45mA(12V In),26mA(24V In); 4-Wire:52mA'(max.),37mA'(12V In),22mA'(24V In) Alarm Current2: 2-Wire: 181 mA(max.), 121 mA(12V In),64mA(24V In); 4-Wire:78mA'(max.),57mA'(12V In),34mA'(24V In) Maximum Ripple Voltage: 30%of applied power Maximum Alarm Threshold: 9.2 Volts DC Alarm and Maintenance Contact Rating: 100 mA @I 36 Volts DC,resistive,25 ohms Maximum Loop Wiring Resistance: 2-Wire 50 Ohms;4-Wire 300 Ohms Trigger inputs: Min On Voltage: 1.5V;Max.:Vin Does not include current draw from attached detectors or EOL relay.2 Does not include reverse polarity current draw from attached detectors. Physical Specifications Module Dimension: Height:6.04 Width:6.04 Depth: 1.00" Weight: 9.6 oz.272(g) Operating Temperature Range: 0—50°C(32—122°F) Operating Humidity Range: 5-95%RH Storage Temperature Range: -20—70°C(-4—158°F) Input Terminals: 14 to 22 AWG Mounting: 411/16"square back box or inside a metal enclosure Operation Modes/LED Status Green Yellow Red Blue Alarm Smoke: Blink 1 sec. Off On Off Alarm CO: Blink 1 sec. Off Off On Alarm Smoke&CO: Blink 1 sec. Off On On No power/No communication: Off Off Off Off Loop wiring fault: Blink 1 sec. On Off Off EZ Walk Test Mode(2-wire only): Blink 1 sec. Blink 5 sec. Off Off Smoke Maintenance(2-wire only): Blink 1 sec. Off Blink 5 sec. Off Smoke Freeze Trouble(P 2WTA-B only): Blink 1 sec. Off Blink 10 sec. Off CO Trouble: Blink 1 sec. Off Off Blink 5 sec. Module Power-Up Sequence/LED Status Condition Duration Maintenance/Freeze trouble LED indication 6 minutes EZ Walk test available 6 minutes after power up or panel reset Ordering Information Part No. Description COSMO-2W 12/24 volt,2-wire,system-connected,combination carbon monoxide/smoke detector with RealTest technology COSMO-4W 12/24 volt,4-wire,system-connected,combination carbon monoxide/smoke detector with RealTest technology COSMOD2W 2-wire interface module(required to use with COSMO-2W models) COSMOD4W 4-wire interface module(required to use with COSMO-4W models) CO-REPL Replacement CO cell for COSMO-2W and COSMO-4W models SENS-RDR Sensitivity reader EOLR-1 End-of-line relay(required with 4-wire systems) *Th_ SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 ©2013 System Sensor. Phone:800-SENSOR2•Fax 630-377-6495 Product specifications subject to change without notice.Visit systemsensor.com SEI SORT for current product information,including the latest version of this data sheet. ,vJ www.systemsensor.com CODS30302•11/13 SYSTEM �$ SENSOR K � ` Outdoor Selectable- r x Output Horns, f y Strobes, and Horn Strobes for Wall Applications SPECTRert SpectrAlerio Advance outdoor audible visible products Amway a 1m are rich with features that cut installation times and maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns, strobes,and horn strobes in the industry.With white or red plastic • Weatherproof per NEMA 4X, IP56 housings,wall or ceiling mounting options,and plain or FIRE-printed • Listed to UL 1638(strobe)and UL 464(horn) devices,SpectrAlert Advance can meet virtually any application • Compatible with System Sensor synchronization protocol and requirement, including indoor,outdoor,wet,and dry applications in legacy SpectrAlert products temperatures from—40°F to 151°F. • Field selectable candela settings: 15, 15/75,30,75,95, 110, 115, Like the entire SpectrAlert Advance line,outdoor horns,strobes, 135, 150, 177,and 185 and horn strobes for wall applications include a variety of features • Automatic selection of 12-or 24-volt operation at 15 and that increase application flexibility and simplify installation. First, 15/75 candela field-selectable settings, including candela,automatic selection of • Rotary switch for horn tone and three volume selections 12-or 24-volt operation,horn tones,and three volume options enable installers to easily adapt devices to meet requirements. • Horn rated at 88+dBA at 16 volts • Rated from—40°F to 151°F Next,SpectrAlert Advance devices use a universal mounting plate • Universal mounting plate with an onboard shorting spring that for both wall and ceiling applications.This mounting plate includes tests wiring continuity before devices are installed an onboard shorting spring that ensures wiring continuity before devices are installed,so installers can verify proper wiring without • Plug-in design with minimal intrusion into the back box mounting the devices and exposing them to potential construction • Tamper-resistant construction damage.Once the plates are mounted,all SpectrAlert Advance • Listed for ceiling or wall mounting devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes(metal back boxes are available separately)that accommodate in-and- Agency Listings out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock-outs located on the back eliminate the need to drill SIGNALING rl 0 UL holes for screw-in mounting. Plastic and metal weatherproof back MEA7300-1653:187 boxes come with 3/4-inch top and bottom conduit entries and 3/4-inch LISTED ® (outdoor strobes) approved 7125-1653:188(horn strobes, knock outs at the back.A screw-in NPT plug with an 0-ring gasket 54011(chimes,horn strobes,horns) APPROVED pp chime strobes) S3593(outdoor and alert strobes) 302s-72 MEA452-05-E 7135-1653:189(horns,chimes) for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications Architect/Engineer Specifications General SpectrAlert Advance outdoor horns,strobes,and horn strobes shall mount to a weatherproof back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•Circuit° Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts.Outdoor SpectrAlert Advance products shall operate between-40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95, 110, 115, 135, 150, 177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options shall be set by a multiple position switch. On four-wire products,the strobe shall be powered independently of the sounder.The horn or horn strobe models shall operate on a coded or non-coded power supply.The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature -40°F to 151°F(-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Rangel 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 2.5"D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.3"D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions(SA-WBB) 5.7"L x 5.1"W x 2.0"D(145 mm L x 130 mm W x 51 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS01201 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed Horn and Horn Strobe Output(dBA) candela ratings must be reduced in accordance with 8-17.5 16-33 24-Volt Nominal this table. Switch Sound Volts Volts Reverberant Anechoic Strobe Output(cd) Position Pattern dB DC FWR DC FWR DC FWR DC FWR Listed Candela Candela rating at—40°F 1 Temporal High 78 78 84 84 88 88 99 98 15 2 Temporal Medium 74 74 80 80 86 86 96 96 15/75 Do not use below 32°F 3 Temporal Low 71 73 76 76 83 80 94 89 30 4 Non- High 75 44 Temporal 82 82 88 88 93 92 100 100 95 70 5 Non- Medium 110 110 Temporal 78 78 85 85 90 90 98 98 115 115 6 Non- Low 75 75 81 81 88 84 96 92 135 135 Temporal 150 150 7t Coded High 82 82 88 88 93 92 101 101 177 177 8t Coded Medium 78 78 85 85 90 90 97 98 185 185 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobe. AVDSo12o1 SpectrAlert Advance Diagrams r 4.7" 2.5" ► l\ 1 i .....i.."I''.50 \ IN ,, MIA II�/111 5.6" (40 /I o =1 1.llj V��® „moi Wall-Mount Horn Strobes ^7�� Wall Plastic Weatherproof Back Box 4104-1414,A* il II � . ® ,® ® 1 ��1i Ii I�ui'=�I'-�_ SII ,�II Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Model Description Wall Horn Strobes P2RK"t 2-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P2RHK"t 2-Wire Horn Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) P2WK"t 2-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2WHK*t 2-Wire Horn Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe,High cd,Red,Outdoor, 120 V(includes plastic weatherproof back box) Wall Strobes SRK"t Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) SRHK"t Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) SWK"t Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) SWHK"t Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) Horns HRKt Horn,Red,Outdoor(includes plastic weatherproof back box) Accessories SA-WBB Red,Metal Weatherproof Back Box SA-WBBW White,Metal Weatherproof Back Box Notes: *Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2RK-P. t Add"-R"to model number for weatherproof replacement device(no back box included),only for use with weatherproof outdoor flush mounting plate,WTP and WTPW. "Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 candela settings.When replacing standard outdoor units both the device and back box must be replaced. *Th_ SYSTEM ©2012 System Sensor. 3825 Ohio Avenue•St.Charles, IL 60174 Product specifications subject to change without notice.Visit systemsensor.com SENSOR Phone:800-SENSOR2•Fax:630-377-6495 for current product information,including the latest version of this data sheet. AVDS01201•3/12