0 z.....".4.... tqco C / "I WConta is41 IR; O www.tyc. 11, Products QU 1o# Vail Fire&Emergen y Services 11/01/16 Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General NOTICE The TYCO Series TY-FRB Sprinklers 1h Description described herein must be installed and " O,f maintained in compliance with this doc �' ' The TYCO Series TY-FRB, 5.6 K-factor, ument, as well as with the applicable , „ Upright (TY313) and Pendent (TY323) standards of the National Fire Protec- [ Sprinklers described in this data sheet tion Association,in addition to the stan- r 1 are quick response,standard coverage, dards of any other authorities having .4 � decorative 3 mm glass bulb-type spray jurisdiction. Failure to do so may impair sprinklers designed for use in light or the performance of these devices. ordinary hazard,commercial occupan- ., cies such as banks, hotels, and shop- The owner is responsible for maintain- „ i ping malls. ing their fire protection system and devices in proper operating condition. The recessed version of the Series TY- The installing contractor or sprinkler FRB Pendent Sprinkler,where applica- manufacturer should be contacted with ble, is intended for use in areas with a any questions. finished ceiling.This recessed pendent sprinkler uses one of the following: • A two-piece Style 15 Recessed Sprinkler Escutcheon with recessed adjust- Identification ment up to 5/8 inch (15,9 mm) from the flush pendent position. Number (SIN) • A two-piece Style 20 Recessed Escutcheon with recessed adjust- TY313 Upright 5.6K, 1/2"NPT ment up to 1/2 inch (12,7 mm) from TY323 Pendent 5.6K, 1/2"NPT ''sn, the flush pendent position. The adjustment provided by the Technical Recessed Escutcheon reduces the Temperature Rating accuracy to which the fixed pipe drops Data 135°F(57°C) to the sprinklers must be cut. 155°F(68°C) Approvals 175°F(79°C) Intermediate level versions of Series200°F(93°C) TY-FRB Sprinklers are described in UL and C-UL Listed 286°F(141°C) Technical Data Sheet TFP357. Sprin- FM, LPCB, and VdS Approved kler guards and shields are described CE Certified Finishes in Technical Data Sheet TFP780. Sprinklers with Polyester Finish are UL Sprinkler: Refer to Table A and C-UL Listed as Corrosion-Resis- Recessed Escutcheon:White Coated, tant Sprinklers. Chrome Plated, or Brass Plated Maximum Working Pressure Physical Characteristics 175 psi (12.1 bar) Frame Bronze 250 psi (17.2 bar)* Button Brass/Copper 'The maximum working pressure of 250 psi Sealing Assembly Stainless IMPORTANT (17.2 bar)only applies to the listing by Un- Steel w/TEFLON Always refer to Technical Data derwriters Laboratories, Inc.(UL). Bulb Glass Sheet TFP700 for the "INSTALLER Discharge Coefficient Compression Screw Bronze WARNING"that provides cautions K=5.6 GPM/psi1/2(80,6 LPM/bar1/2) Deflector Bronze with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 FEBRUARY 2014 TFP172 olti OF pi TFP172 � 11 Page2of4 z. 4. # / Components: * ** 1 Frame 4 Bulb Temperature rating is Pipe thread connections per ISO 7-1 D. ? g07 indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 0 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11,1 mm) �mergen y Services Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESRME:ON 6* °%:"ellfr;: "'Tr>r i N i ------------- /5 =, 7/16" �_ (11,1 mm) lii `'■rc 17 4 ( NOMINAL 2° I I (I I i 2 II MAKE IN (50,8 mm) �, / D' r2" \Ij CV 1-3/8" 1 // i* (50,8 mm) (34,9 mm) 3 ` WRENCH 71 / ,it FLATS 1/2" NPT** DEFLECTOR* --- 2-7/8"(73,0 mm)DIA. --I CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT(TY313)AND PENDENT(TY323)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE L. Operation Installation The glass bulb contains a fluid which The TYCO Series TY-FRB,5.6 K-factor, WRENCH RECESS expands when exposed to heat.When Upright (TY313) and Pendent(TY323) (USE ONLY the rated temperature is reached, the Sprinklers must be installed in accor- 00/1 END"A") fluid expands sufficiently to shatter the dance with this section. �,� glass bulb, allowing the sprinkler to General Instructions FIGURE 2 activate and water to flow. Do not install any bulb-type sprinkler if W-TYPE 6 the bulb is cracked or there is a loss SPRINKLER WRENCH Design of liquid from the bulb. With the sprin- kler held horizontally, a small air WRENCH bub- Criteria ble should be present. The diameter RECESSRCof the air bubble is approximately 1/16 The TYCO Series TY-FRB,5.6 K-factor, inch (1,6 mm)for the 135°F(57°C)and Upright (TY313) and Pendent(TY323) 3/32 inch(2,4 mm)for the 286°F(141°C) �,� Sprinklers are intended for fire protec- temperature ratings. /ice 71•Htion systems designed in accordance with the standard installation rules rec- A leak-tight 1/2 inch NPT sprinkler joint ognized by the applicable Listing or should be obtained by applying a min- Approval agency (such as, UL Listing min- imum to maximum torque of 7 to 14 11 11 " is based on the requirements of NFPA ft.-lbs. (9,5 to 19,0 Nm). Higher levels Noir, 13, and FM Approval is based on the of torque can distort the sprinkler Inlet PUSH WRENCH requirements of FM's Loss Prevention with consequent leakage or impairment Data Sheets).Only the Style 15 or Style of the sprinkler. IN TO ENSURE 20 Recessed Escutcheon is to be used Do not attempt to compensate for ENGAGEMENT for recessed pendent installations. insufficient adjustment in the Escutch- WITH SPRINKLER eon Plate by under-or over-tightening WRENCHING AREA the sprinkler. Re-adjust the position of FIGURE 3 the sprinkler fitting to suit. W-TYPE 7 RECESSED SPRINKLER WRENCH Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. do,ti OF zo ilk.1 ' w' 11 z 4. Step 3. Tighten the sprinkler into the 4 b sprinkler fitting using only the W-Type (73,0 sprinkler DIA. D.3111OJ I 0 6 Sprinkler Wrench(Figure 2).With ref- erence to Figure 1, apply the W-Type 6 2-1/4" DIA. Vail Fire&Emergen:y Services Sprinkler Wrench to the wrench flats. FACE OF (57,2 mm) 11/01/16 Torque sprinklers 7 to 14 ft.-lbs. (9,5 to SPRINKLER 19,0 Nm). FITTING 5/8"(15,9 mm) Recessed Pendent Sprinklers l \ - FLUSH The Series TY-FRB Recessed Pendent 3/8±5/16" =1`�`i' .1 1' � Sprinklers must be installed in accor- (9,5±7,9 mm) y - '% dance with the following instructions. } / WO Step A.After installing the Style 15 or MOUNTING 1/8" Style 20 MountingPlate over the s rin- kler threads, ad with pipe-thread SURFACE _ (3,2 mm) sealant applied to the pipe threads, CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) hand-tighten the sprinkler into the TY-FRB PLATE 3/4" sprinkler fitting. (19,1 mm) Step B. Tighten the sprinkler into the FIGURE 4 Step B. fitting using onin the W-Type SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) 7spriRecessed SprinkleruinWrench (Figure WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 3).With reference to Figure 1,apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque 2-7/8"DIA. sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 (73,0 mm) Nm). FACE OF Step C.After ceiling installation and fin- SPRINKLER 2-1/4" DIA. _ ishing, slide on the Style 15 or Style 20 FITTING (57,2 mm) Closure over the Series TY-FRB Sprin- 5/16±1/4" 1/2" 12,7 mm) kler and push the Closure over the (7,9±6,4 mm) ( Mounting Plate until its flange comes in + miFLUSH contact with the ceiling. / =11 7 Care and t / �` + ' MOUNTING ! 1/8" J Maintenance SURFACE (3,2 mm) The TYCO Series TY-FRB,5.6 K-factor, I Upright (TY313) and Pendent (TY323) CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) Sprinklers must be maintained and ser- TY-FRB PLATE 7/8"(22,2 mm) viced in accordance with this section. FIGURE 5 Before closing a fire protection system SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) main control valve for maintenance WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 work on the fire protection system RECESSED ESCUTCHEON that it controls, obtain permission to shut down the affected fire protection Modified sprinklers must be replaced. standards of any other authorities hav- systems from the proper authorities Sprinklers that have been exposed to ing jurisdiction. Contact the installing and notify all personnel who may be corrosive products of combustion, but contractor or sprinkler manufacturer affected by this action. have not operated, should be replaced regarding any questions. Absence of the outer piece of an if they cannot be completely cleaned Automatic sprinkler systems are rec- escutcheon, which is used to cover by wiping the sprinkler with a cloth or ommended to be inspected, tested, a clearance hole, can delay sprinkler by brushing it with a soft bristle brush. and maintained by a qualified Inspec- operation in a fire situation. Care must be exercised to avoid dam- tion Service in accordance with local The owner must assure that the sprin age to the sprinklers before,during,and requirements and/or national codes. klers are not used for hanging any after installation. Sprinklers damaged objects and that the sprinklers are only by dropping, striking, wrench twist/ cleaned by means of gently dusting slippage, or the like, must be replaced. with a feather duster; otherwise, non- Also, replace any sprinkler that has a operation in the event of a fire or inad- cracked bulb or that has lost liquid from vertent operation may result, its bulb. (Ref. Installation Section.) Sprinklers which are found to be leak- The owner is responsible for the ing or exhibiting visible signs of corro- inspection,testing,and maintenance of sion must be replaced. their fire protection system and devices in compliance with this document, as Automatic sprinklers must never be well as with the applicable standards painted, plated, coated, or other- of the National Fire Protection Associa- wise altered after leaving the factory. tion (e.g., NFPA 25), in addition to the TFP172 �41111. Page 4 of 4 P/N* 77 - XXX - X - XXX � I SPRINKLER TEMPERrKta l ni e 8 Emergen;y Services FINISH RATINUS'1/ 6 SIN 1 NATURAL BRASS 135 135°F(57°C) 370 5.6K UPRIGHT(1/2'"NPT) TY313 3 PURE WHITE(RAL9010)"" 155 155°F(68°C) POLYESTER 371 5.6K PENDENT(1/2"NPT) TY323 q SIGNAL WHITE(RAL9003) 175 175°F(79°C) POLYESTER •Use suffix"I"for ISO 7-1 connection; 9 CHROME PLATED 200 200°F(93°C) for example,77-370-4-175-I "Eastern Hemisphere sales only 286 286°F(141°C) TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Ordering Warranty Procedure For warranty terms and conditions,visit Contact your local distributor for avail- www.tyco-fire.com. ability. When placing an order, indicate the full product name and Part Num- ber(P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pen- dent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify)tem- perature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify:Style 15 Recessed Escutcheon with (specify`)finish, P/N(specify") Specify: Style 20 Recessed Escutch- eon with(specify°)finish, P/N(specify") *Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright©2014 Tyco Fire Products, LP. All rights reserved. two TEFLON is trademark of The DuPont Corporation. Fire Protection Products f . e n , e 1 e . .,,,, .,., 1 ri r .,.„ „, {4r .41111111. 10' ‘i,,, r S ..,..,:, iipo• „0,,„;., z' F 0 ' rei__. +. rn Schedule:1Q Mr d Schedule ' { 4,.-- Submittal Data Sheet ' # 'f F bk Q 11/01/16 FM Approved and Fully Listed Sprinkler Pipe SCHEDULE 10 SPECIFICATIONS Wheatland's Schedule 10 and Schedule 40 steel fire sprinkler pipe is FM Approved and UL, NOMINAL NOMINAL C-UL and FM Listed. NPS NOM OD NOM ID WALL WEIGHT UL PIECES In. mm In. mm In. mm lbs./ft. kg/m CRR" Lift Approvals and Specifications Both products meet or exceed 1% 1.660 42.2 1.442 36.6 .109 2.77 1.81 2.69 7.3 61 the following standards: 1% 1.900 48.3 1.682 42.7 .109 2.77 2.09 3.11 5.8 61 • ASTM A135,Type E, Grade A (Schedule 10) 2 2.375 60.3 2.157 54.8 .109 2.77 2.64 3.93 4.7 37 • ASTM A795,Type E,Grade A(Schedule 40) 21/2 2.875 73.0 2.635 66.9 .120 3.05 3.53 5.26 3.5 30 • NFPA 13 3 3.500 88.9 3.260 82.8 .120 3.05 4.34 6.46 2.6 19 Manufacturing Protocols Schedule 10 and Schedule 40 are subjected 4 4.500 114.3 4.260 108.2 .120 3.05 5.62 8.37 1.6 19 to the toughest possible testing protocols to 5 5.563 141.3 5.295 134.5 .134 3.40 7.78 11.58 1.5 13 ensure the highest quality and long-lasting performance. 6 6.625 168,3 6.357 161.5 .134 3.40 9,30 13.85 1.0 10 8 8.625 219.1 8.249 209.5 .188 4.78 16.96 25.26 2.1 7 Finishes and Coatings All Wheatland black steel fire sprinkler pipe 'Calculated using Standard UL CRR formula,UL Fire Protection Directory,Category VIZY. `The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. up to 6" receives a proprietary mill coating to Threaded Schedule 40 steel pipe is used as the benchmark(value of 1.0). ensure a clean,corrosion-resistant surface that outperforms and outlasts standard lacquer coatings.This coating allows the pipe to be SCHEDULE 40 SPECIFICATIONS easily painted,without special preparation. Schedule 10 and Schedule 40 can be ordered in NOMINAL NOMINAL black,or with hot dip galvanizing,to meet NPS NOM OD NOM ID WALL WEIGHT UL PIECES FM/UL requirements for dry systems that meet in. mm in. mm in. mm Ibs./ft. kg/m CRR* Lift the zinc coating specifications of ASTM A795 or A53.All Wheatland galvanized material is 1 1.315 33.4 1.049 26.6 .133 3.38 1,68 2.50 1.00 70 also UL Listed. 1% 1.660 42.2 1.380 35.1 .140 3.56 2.27 3.39 1.00 51 Product Marking 1Yz 1.900 48.3 1.610 40.9 .145 3.68 2.72 4.05 1.00 44 Each length of Wheatland fire sprinkler 2 2.375 60.3 2.067 52.5 .154 3.91 3.66 5.45 1.00 30 pipe is continuously stenciled to show the manufacturer,type of pipe,grade,size "Calculated using Standard UL CRR formula,UL Fire Protection Directory,Category VIZY. and length. Barcoding is acceptable as a 'The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark(value of 1.0). , supplementary identification method. ® C (III APP® SUBMITTAL INFORMATION PROJECT: CONTRACTOR: DATE: ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: LOCATIONS: COMMENTS: ❑ BLACK ❑ HOT-DIP GALVANIZED eat an Tube --- - a DIVISION OF ZEKELMAN INDUSTRIES