HomeMy WebLinkAboutB16-0481_A10.02_1482188421.pdfDIVISION 06 - WOODS AND PLASTICS ROUGH CARPENTRY DIMENSION LUMBER: 1. DIMENSION LUMBER FOR BLOCKING, BACKING, AND MISCELLANEOUS FRAMING SHALL BE CONSTRUCTION GRADE, Fb - SINGLE = 1350 psi. SPRUCE-PINE-FIR (SOUTH). 2. DIMENSION LUMBER FOR STUDS SHALL BE HEM - FIR. NO. 2 & BTR. 3. BOARDS, ONE INCH THICK AND UNDER WHERE EXPOSED, SHALL BE NO. 1 COMMON DOUGLAS FIR, WHITE FIR, WHITE SPRUCE, OR PONDEROSA PINE UNLESS NOTED OTHERWISE. MOISTURE CONTENT SHALL NOT EXCEED 19 PERCENT. 4. BOARDS, ONE INCH THICK AND UNDER WHERE CONCEALED BY PERMANENT CONSTRUCTION, SHALL BE NO. 2 OR BETTER. WOOD PRODUCTS: 1. FORMALDEHYDE EMISSIONS: COMPLY WITH LIMITS IN GREEN BUILDING CODE NOTES IN DRAWINGS. 2. INTERIOR PLYWOOD WHERE COMPLETELY CONCEALED BY PERMANENT CONSTRUCTION SHALL BE C-D PLUGGED INT-APA. 3. EXTERIOR PLYWOOD WHERE CONCEALED OR USED FOR BACKING FOR OTHER MATERIALS SHALL BE C-D EXT-APA. NAILS, SPIKES, AND STAPLES SHALL BE GALVANIZED FOR EXTERIOR LOCATIONS, HIGH HUMIDITY LOCATIONS, AND TREATED WOOD; PLAIN FINISH FOR OTHER INTERIOR LOCATIONS. USE SIZES AND TYPES TO SUIT APPLICATION. BOLTS, NUTS, WASHERS, LAGS, AND SCREWS SHALL BE MEDIUM CARBON STEEL. USE SIZE AND TYPE TO SUITE APPLICATION, GALVANIZED FOR EXTERIOR LOCATIONS, HIGH HUMIDITY LOCATIONS, AND TREATED WOOD; PLAIN FINISH FOR OTHER INTERIOR LOCATIONS. PROVIDE TOGGLE BOLTS OR TAPCON FASTENERS FOR ANCHORAGE TO HOLLOW MASONRY. PROVIDE EXPANSION SHIELD AND LAG BOLT FOR ANCHORAGE TO SOLID MASONRY OR CONCRETE. PROVIDE BOLTS OR POWER ACTIVATED FASTENERS FOR ANCHORAGE TO STEEL. PLYWOOD, FRAMING, BLOCKING, ETC. ON THE INTERIOR OR EXTERIOR IS REQUIRED TO BE FIRE-RETARDANT-TREATED AND SHALL BE BY PRESSURE TREATMENT IN ACCORDANCE WITH AWPB STANDARD C-20 FOR LUMBER AND C-27 FOR PLYWOOD. 1. TREATED MATERIAL SHALL BE LABELED TO INDICATE PRESSURE TREATMENT. 2. TREATMENT SHALL BE FOR CLASS "A" FLAME SPREAD RATING. FRAMING SHALL BE IN ACCORDANCE WITH GENERALLY ACCEPTED FRAMING PRACTICES. 1. BUCKS, WHERE REQUIRED FOR FRAMES, SHALL BE NOMINAL 2 INCH THICK MATERIAL AND OF WIDTH REQUIRED BY CONDITIONS. ANCHOR INTO CONCRETE OR MASONRY WALLS LAG BOLTS AND SHIELDS. 2. BLOCKING SHALL BE FURNISHED WHERE REQUIRED FOR ATTACHMENT OF OTHER MATERIALS. THEY SHALL BE PLUMB, LEVEL, STRAIGHT AND SET TO LINE. ALL GROUNDS SHALL BE SOLID. GROUNDS SHALL BE PROVIDED AT ALL OPENINGS IN WALLS REQUIRING WOOD TRIM OR WHERE GRILLES ARE BEING INSTALLED. 3. CUT MEMBERS SQUARE ON BEARINGS, CLOSELY FITTED, ACCURATELY CUT TO REQUIRED LINES AND LEVELS AND RIGIDLY SECURED IN PLACE. 4. INSTALL MISCELLANEOUS BLOCKING, NAILING STRIPS, FRAMING, SHEATHING, AND BACKING AS REQUIRED FOR ATTACHING FASTENERS, ACCESSORIES FOR WALL ITEMS,AND ETC. 5. INSTALL MEMBERS TRUE, PLUMB, AND LEVEL. SECURE IN PLACE. 6. SPACE MISCELLANEOUS FRAMING AND FURRING AT 16 INCHES ON CENTER. 7. CONSTRUCT MEMBERS OF CONTINUOUS PIECES OF LONGEST POSSIBLE LENGTHS. FINISH CARPENTRY THIS SECTION INCLUDES FINISH CARPENTRY AND FABRICATED PLASTIC ITEMS, OTHER THAN SHOP FABRICATED WORK, WITH ATTACHMENT ACCESSORIES. STORE INDOORS IN VENTILATED AREAS WITH CONSTANT 60 DEGREE FAHRENHEIT TEMPERATURE AND 55 PERCENT MAXIMUM RELATIVE HUMIDITY. WOOD PRODUCTS: 1. FORMALDEHYDE EMISSIONS: COMPLY WITH LIMITS IN GREEN BUILDING CODE NOTES IN DRAWINGS. 2. SOFTWOOD LUMBER: PS 20; CUSTOM GRADE IN ACCORDANCE WITH AWI; MAXIMUM MOISTURE CONTENT OF 5 TO 10 PERCENT FOR INTERIOR WORK AND 15 PERCENT FOR EXTERIOR WORK. 3. HARDWOOD LUMBER: PS 58 OR FED. SPEC MM-L-736; CUSTOM GRADE IN ACCORDANCE WITH AWI; MAXIMUM MOISTURE CONTENT OF 5 TO 10 PERCENT. 4. WOOD PARTICLE BOARD: MEDIUM DENSITY PARTICLEBOARD (45 LBS.). 5. WOOD FIBER BOARD: MEDIUM DENSITY FIBERBOARD (37 TO 50 LBS. PER CUBIC FOOT). 6. SOFTWOOD PLYWOOD: APA A-B. 7. HARDBOARD: PRESSED WOOD FIBER; STANDARD TEMPERED SERVICE GRADE. FRAME CONSTRUCTION: HARDWOOD AS INDICATED IN THE SCHEDULE, SOLID WOOD JAMBS AND HEAD ACCURATELY HOUSED TOGETHER AND SECURED WITH NAILS AND GLUE AS REQUIRED. APPLY STOPS OF SAME SPECIES AS FRAME. INTERIOR WOOD BLIND DOOR FRAMES: AWI CUSTOM - ANY CLOSED GRAIN HARDWOOD OR MDF. NAILS: SIZE AND TYPE TO SUIT APPLICATION. BOLTS, NUTS, WASHERS, LAGS, AND SCREWS: SIZE AND TYPE TO SUIT APPLICATION; NON-CORROSIVE FOR HIGH HUMIDITY, PLAIN FINISH AT OTHER INTERIOR LOCATIONS. INSTALLATION: 1. VERIFY THAT MECHANICAL, ELECTRICAL, AND BUILDING ITEMS AFFECTING THIS SECTION ARE PLACED AND READY TO RECEIVE FINISH CARPENTRY ITEMS. 2. SET AND SECURE MATERIALS AND COMPONENTS IN PLACE, PLUMB, AND LEVEL. 3. FIT EXPOSED EDGES OF PLYWOOD AND PARTICLE BOARD SHELVING AND SITE MADE CASEWORK WITH HARDWOOD EDGING. 4. INSTALL HARDWARE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 5. SAND WORK SMOOTH AND SET EXPOSED NAILS AND SCREWS. APPLY WOOD FILLER IN EXPOSED NAIL AND SCREW INDENTATIONS. CASEWORK AND COUNTERTOPS SECTION INCLUDES: 1. FABRICATION AND INSTALLATION OF SHELVING AND COUNTERTOPS. 2. INSTALLATION OF OWNER-PROVIDED CABINETS. FORMALDEHYDE EMISSIONS OF WOOD PRODUCTS: COMPLY WITH LIMITS IN GREEN BUILDING CODE NOTES IN DRAWINGS. ADHESIVES AND SEALANTS: COMPLY WITH LIMITS IN GREEN BUILDING CODE NOTES IN DRAWINGS. PROVIDE INSTALLATION MATERIALS COMPLYING WITH FINISH CARPENTRY SPECIFICATIONS AND "ARCHITECTURAL WOODWORKING STANDARDS" . PROVIDE PREMIUM GRADE MATERIALS AND FABRICATION AT SHOWROOM AND CUSTOM GRADE AT BACK OF HOUSE SPACES. COUNTERTOPS: 1. SUBSTRATE: PARTICLE BOARD PER ANSI A208.1, M2 MADE WITH EXTERIOR GLUE, OR EXTERIOR SOFTWOOD PLYWOOD COMPLYING WITH DOC PS 1, GRADE C-C PLUGGED, TOUCH-SANDED.. 2. HIGH-PRESSURE DECORATIVE LAMINATE: NEMA LD 3, GRADE HGS AT TOPS AND EDGES. 3. SOLID SURFACE MATERIAL: HOMOGENEOUS SOLID SHEETS OF RESIN, PER ANSI SS1. 4. SIMULATED STONE: SOLID SHEETS OF QUARTZ AGGLOMERATE WITH MATRIX OF FILLED PLASTIC RESIN, COMPLYING WITH "PHYSICAL CHARACTERISTICS OF MATERIALS " ARTICLE OF ANSI SS1. SHELVING: 1. SUBSTRATE: PARTICLE BOARD PER ANSI A208.1, M2 MADE WITH EXTERIOR GLUE, OR EXTERIOR SOFTWOOD PLYWOOD COMPLYING WITH DOC PS 1, GRADE C-C PLUGGED, TOUCH-SANDED.. 2. HIGH-PRESSURE DECORATIVE LAMINATE: NEMA LD 3, GRADE HGS AT TOPS AND EDGES. INSTALLATION: COMPLY WITH "ARCHITECTURAL WOODWORKING STANDARDS". MATCH OR EXCEED GRADE OF INSTALLED PRODUCTS. DIVISION 07 - THERMAL AND MOISTURE PROTECTION FIRESTOPPING VOC CONTENT OF SEALANT PRODUCTS: PER GREEN BUILDING CODE NOTES IN DRAWINGS. FIRE-TEST-RESPONSE CHARACTERISTICS: FIRESTOPPING JOINT AND PENETRATION ASSEMBLIES SHALL COMPLY WITH THE FOLLOWING: 1. TESTED BY UL, INTERTEK ETL SEMKO. OR FM GLOBAL. 2. IDENTICAL PRODUCTS AND ASSEMBLIES TO THOSE TESTED. JOINTS IN OR BETWEEN FIRE-RESISTANCE RATING CONSTRUCTION: RATINGS DETERMINED PER ASTM E 814 OR UL 1479. 1. FIRE RATING: EQUAL TO OR EXCEEDING RATING OF JOINED CONSTRUCTION. 2. SMOKE RATING: L-RATING DETERMINED PER UL 2079, NOT TO EXCEED 5.0 CFM/FT IN SMOKE BARRIERS. 3. EXPOSED JOINT SYSTEMS: FLAME SPREAD INDEX LESS THAN 25 AND SMOKE DEVELOPED INDEX LESS THAN 450, PER ASTM E84. PENETRATIONS IN FIRE-RESISTANCE RATING CONSTRUCTION: RATINGS DETERMINED PER ASTM E1966 OR UL 2079. 1. F RATING: EQUAL TO OR EXCEEDING RATING OF PENETRATED CONSTRUCTION. 2. T RATING: IN HORIZONTAL ASSEMBLIES, AT LEAST 1 HOUR, BUT NOT LESS THAN FIRE RESISTANCE OF PENETRATED CONSTRUCTION. 3. SMOKE RATING: L-RATING DETERMINED PER UL 2079, NOT TO EXCEED 5.0 CFM/FT IN SMOKE BARRIERS. 4. EXPOSED PENETRATION SYSTEMS: FLAME SPREAD INDEX LESS THAN 25 AND SMOKE DEVELOPED INDEX LESS THAN 450, PER ASTM E84. PREPARATION: CLEAN, PRIME AND MASK ACCORDING TO SEALANT MANUFACTURER'S INSTRUCTIONS. INSTALL FIRESTOPPING ASSEMBLIES TO COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS AND PUBLISHED DRAWINGS. ASSEMBLY SCHEDULE: SUBMIT PROPOSED ASSEMBLIES FOR ARCHITECT'S ACCEPTANCE. INDICATE LOCATIONS IN WORK AND ASSEMBLY NUMBERS FROM ONE OR MORE OF THE FOLLOWING SOURCES: 1. UL: FIRE RESISTANCE DIRECTORY. 2. INTERTEK ETL SEMKO: DIRECTORY OF LISTED BUILDING PRODUCTS, FIRESTOP SYSTEMS SECTION. 3. FM GLOBAL: BUILDING MATERIALS APPROVAL GUIDE. JOINT SEALANTS VOC CONTENT OF INTERIOR SEALANTS: PER GREEN BUILDING CODE NOTES IN DRAWINGS. SEALANTS: 1. SILICONE JOINT SEALANTS: MILDEW-RESISTANT, NONSAG, USE NT, ASTM C920. 2. URETHANE JOINT SEALANTS: POURABLE, USE T, ASTM C920. 3. LATEX JOINT SEALANTS: TYPE OP, GRADE NF, ASTM C834. JOINT SEALANT BACKING: CYLINDRICAL, ASTM C1330, TYPE C UNLESS OTHERWISE INDICATED IN JOINT SEALANT MANUFACTURER'S INSTRUCTIONS. PREPARATION: CLEAN, PRIME AND MASK ACCORDING TO SEALANT MANUFACTURER'S INSTRUCTIONS. INSTALL SEALANTS USING PROVEN TECHNIQUES THAT COMPLY WITH THE FOLLOWING AND AT THE SAME TIME BACKINGS ARE INSTALLED: 1. PLACE SEALANTS SO THEY DIRECTLY CONTACT AND FULLY WET JOINT SUBSTRATES. 2. COMPLETELY FILL RECESSES IN EACH JOINT CONFIGURATION. 3. PRODUCE UNIFORM, CROSS-SECTIONAL SHAPES AND DEPTHS RELATIVE TO JOINT WIDTHS THAT ALLOW OPTIMUM SEALANT MOVEMENT CAPABILITY. TOOLING OF NONSAG SEALANTS: IMMEDIATELY AFTER SEALANT APPLICATION AND BEFORE SKINNING OR CURING BEGINS, TOOL SEALANTS TO FORM SMOOTH, UNIFORM BEADS OF CONFIGURATION INDICATED; TO ELIMINATE AIR POCKETS; AND TO ENSURE CONTACT AND ADHESION OF SEALANT WITH SIDES OF JOINT. 1. REMOVE EXCESS SEALANT FROM SURFACES ADJACENT TO JOINTS. 2. USE TOOLING AGENTS THAT ARE APPROVED IN WRITING BY SEALANT MANUFACTURER AND THAT DO NOT DISCOLOR SEALANTS OR ADJACENT SURFACES. 3. PROVIDE CONCAVE JOINT PROFILE PER FIGURE 8A IN ASTM C 1193, UNLESS OTHERWISE INDICATED. DIVISION 08 - DOORS, FRAMES AND HARDWARE STOREFRONT PROVIDED UNDER SEPARATE CONTRACT. DRAWING INFORMATION IS FOR COORDINATION. HOLLOW METAL DOORS AND FRAMES PROVIDE LABELED OR NON-LABELED DOORS AND FRAMES FRAMES IN THE DIMENSIONS AND TYPE SHOWN ON DRAWINGS IN 18 GAUGE FOR INTERIOR DOORS AND FRAMES AND 16 GAUGE GALVANIZED FOR EXTERIOR DOORS AND FRAMES. PROVIDE REINFORCING FOR SPECIFIED HARDWARE. DOORS AND FRAMES SHALL BE SHOP PRIMED. SET FRAMES ACCURATELY INTO POSITION, PLUMBED, ALIGNED AND BRACED UNTIL PERMANENT ANCHORS ARE SET. AFTER WALL CONSTRUCTION REMOVE TEMPORARY BRACING. AT IN-PLACE CONSTRUCTION, SET FRAMES AND SECURE WITH SUITABLE ANCHORAGE DEVICES. BEVEL STRIKE EDGE OF SINGLE ACTING DOORS 1/8 INCH IN 2 INCHES. PREPARE DOORS TO RECEIVE HARDWARE. REFER TO HARDWARE SCHEDULE FOR HARDWARE REQUIREMENTS. INSTALL DOORS PLUMB AND SQUARE, AND WITH MAXIMUM DIAGONAL DISTORTION OF 1/16 INCH. INSTALL HARDWARE IN ACCORDANCE WITH REQUIREMENTS STATED IN HARDWARE SCHEDULE. WOOD DOORS PROVIDE SOLID CORE DOORS COMPLYING WITH "ARCHITECTURAL WOODWORKING STANDARDS". 1. PAINTED DOORS: CUSTOM GRADE 2. DOORS WITH TRANSPARENT FINISH: PREMIUM GRADE. FLUSH INTERIOR DOORS SHALL BE 1-3/4 INCH THICK BIRCH FACE VENEER DOOR. BEVEL STRIKE EDGE OF SINGLE ACTING DOORS 1/8 INCH IN 2 INCHES. PREPARE DOORS TO RECEIVE HARDWARE. REFER TO HARDWARE SCHEDULE FOR HARDWARE REQUIREMENTS. INSTALL WOOD DOORS PLUMB AND SQUARE, AND WITH MAXIMUM DIAGONAL DISTORTION OF 1/16 INCH. INSTALL HARDWARE IN ACCORDANCE WITH REQUIREMENTS STATED IN HARDWARE SCHEDULE. HARDWARE PROVIDE ITEMS AS LISTED IN HARDWARE SCHEDULE ON SHEET C103, COMPLETE TO FUNCTION AS INDICATED. INSTALL HARDWARE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS, USING PROPER TEMPLATES. ACCURATELY AND PROPERLY FIT HARDWARE TO DOORS AND FRAMES. REMOVE EXPOSED PARTS UNTIL AFTER PAINT FINISHING IS COMPLETED. RE-INSTALL AFTER FINISHING IS COMPLETED. FIT FIXED PARTS SNUG AND FLUSH. ADJUST OPERATING PARTS TO MOVE FREELY AND SMOOTHLY WITHOUT BINDING, STICKING, OR WITH EXCESSIVE CLEARANCE. AFTER THE WORK HAS BEEN OTHERWISE COMPLETED, EXAMINE HARDWARE IN PLACE FOR COMPLETE AND PROPER INSTALLATION. LUBRICATE BEARING SURFACES OF MOVING PARTS. ADJUST LATCHING AND HOLDING DEVICES FOR PROPER FUNCTION. ADJUST DOOR CONTROL DEVICES TO PROPER SPEED AND POWER. CLEAN EXPOSED SURFACES AND CHECK FOR SURFACE DAMAGE OPERATING HARDWARE SHALL BE LEVER - TYPE, CENTERED BETWEEN 30"-44" OFF THE FLOOR AND OPERABLE. 5LB. MAX. FORCE. NO DOORS ARE TO REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST TO OPERATE. GLASS STOREFRONT GLASS PROVIDED UNDER SEPARATE CONTRACT. DIVISION 09 - FINISHES GYPSUM WALLBOARD SYSTEM PERFORM GYPSUM WALLBOARD SYSTEMS WORK IN ACCORDANCE WITH RECOMMENDATIONS OF ASTM C754 AND GA216 UNLESS OTHERWISE SPECIFIED IN THIS SECTION. 1. GA 216 - RECOMMENDED SPECIFICATIONS FOR THE APPLICATION AND FINISHING OF GYPSUM BOARD. 2. ASTM C 754 - INSTALLATION OF STEEL FRAMING MEMBERS TO RECEIVE SCREW-ATTACHED GYPSUM WALLBOARD, BACKING BOARD, OR WATER-RESISTANT BACKING BOARD. PROVIDE METAL FRAMING MATERIALS IN ACCORDANCE WITH GA 216. 1. STUDS: SCREW-TYPE CEE-SHAPED MINIMUM 20 GAUGE. 2. RUNNERS: MATCH STUDS. 3. FURRING MEMBERS: SCREW-TYPE HAT-SHAPED 20 GAUGE. 4. PROVIDE CHANNELS AND HANGER WIRE IN ACCORDANCE WITH GA 216. 5. FASTENERS AND ANCHORAGES IN ACCORDANCE WITH GA 216. PROVIDE GYPSUM WALLBOARD MATERIALS IN ACCORDANCE WITH RECOMMENDATIONS OF GA 216. 1. STANDARD GYPSUM BOARDS: 5/8 INCH THICK, MAXIMUM PERMISSIBLE LENGTHS. ENDS SQUARE CUT, TAPERED EDGES. 2. FIRE-RATED GYPSUM BOARDS: UL RATED, 5/8 INCH THICK, MAXIMUM PERMISSIBLE LENGTHS. 3. MOISTURE RESISTANT GYPSUM BOARD: a. 5/8 INCH THICK, MAXIMUM PERMISSIBLE LENGTHS. ENDS SQUARE CUT; TAPERED EDGES. b. PROVIDE IN WET AREAS, INCLUDING BUT NOT LIMITED TO RESTROOMS AND MOP SINK LOCATIONS. 4. AGGREGATE PORTLAND CEMENT BOARD, 1/2 INCH THICK, WITH POLYMER-COATED, WOVEN-GLASS MESH IN BACK AND FRONT SURFACES. PROVIDE GYPSUM WALLBOARD ACCESSORIES IN ACCORDANCE WITH GA 216. 1. CORNER BEADS SHALL BE METAL. 2. PROVIDE REINFORCING TAPE, JOINT COMPOUND, ADHESIVE, WATER FASTENERS IN ACCORDANCE WITH GA 216. FRAMING INSTALLATION: 1. INSTALL MEMBERS TRUE TO LINES AND LEVELS TO PROVIDE SURFACE FLATNESS WITH MAXIMUM VARIATION OF 1/8 INCH IN 10 FEET (1/960) IN ANY DIRECTION 2. METAL STUDS SHALL BE 16 INCHES ON CENTER UNLESS OTHERWISE INDICATED. 3. PARTITION HEIGHTS SHALL BE FULL HEIGHT FROM FLOOR TO ROOF CONSTRUCTION ABOVE AS/OR INDICATED ON THE DRAWINGS. 4. INSTALL DOUBLE STUDS AT DOOR FRAME JAMBS. INSTALL RUNNERS ON EACH SIDE OF OPENING AT FRAME HEAD HEIGHT BETWEEN JAMB STUDS AND ADJACENT STUDS. 5. INSTALL BLOCKING BEHIND DRYWALL FOR SUPPORT OF PLUMBING FIXTURES, TOILET PARTITIONS, WALL CABINETS, TOILET ACCESSORIES, HARDWARE AND ELSEWHERE AS REQUIRED. 6. COORDINATE INSTALLATION OF BUCKS, ANCHORS, BLOCKING, ELECTRICAL, AND MECHANICAL WORK WHICH IS TO BE PLACED IN OR BEHIND PARTITION FRAMING. ALLOW SUCH ITEMS TO BE INSTALLED AFTER FRAMING IS COMPLETE. 7. ERECT WALL FURRING DIRECTLY ATTACHED TO CONCRETE BLOCK AND CONCRETE WALLS. 8. SPACE FURRING CHANNELS MAXIMUM 16 INCHES ON CENTER, NOT MORE THAN 4 INCHES FROM FLOOR AND CEILING BEARING. BOARD INSTALLATION: 1. ERECT SINGLE LAYER STANDARD GYPSUM BOARD IN DIRECTION MOST PRACTICAL AND ECONOMICAL, WITH ENDS AND EDGES OCCURRING OVER FIRM BEARING. 2. ERECT SINGLE LAYER FIRE-RATED GYPSUM BOARD VERTICALLY, WITH EDGES AND ENDS OCCURRING OVER FRAMING. 3. USE SCREWS WHEN FASTENING GYPSUM BOARD TO METAL FURRING OR FRAMING. FINISHING: 1. PLACE CORNER BEADS AT EXTERNAL CORNERS. USE LONGEST PRACTICAL LENGTHS. PLACE EDGE TRIM WHERE GYPSUM BOARD ABUTS DISSIMILAR MATERIALS. 2. TAPE, FILL, AND SAND EXPOSED JOINTS, EDGES, CORNERS, OPENINGS, AND FIXTURES, TO PRODUCE SURFACE READY TO RECEIVE SURFACE FINISHES. FEATHER COATS ONTO ADJOINING SURFACES SO THAT CAMBER IS MAXIMUM 1/32 INCH. FINISHING OF TAPING IS NOT REQUIRED ABOVE CEILING LINE. REMOVE AND REINSTALL DEFECTIVE WORK. ACOUSTICAL CEILINGS CEILING SYSTEMS: AS INDICATED IN FINISH SCHEDULE. 1. ASTM C 636 - STANDARD PRACTICE FOR INSTALLATION OF METAL CEILING SUSPENSION SYSTEMS FOR ACOUSTIC TILE AND LAY-IN PANELS. 2. SUSPENSION SYSTEM: HEAVY DUTY, EXCEPT WHERE INTERMEDIATE DUTY IS PERMITTED BY CODE FOR INSTALLATION INDICATED. INSTALLATION: 1. INSTALL ACOUSTICAL CEILING SYSTEMS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND ASTM C 636 TO PRODUCE FINISHED CEILING TRUE TO LINES AND LEVELS AND FREE FROM WARPED, SOILED, OR DAMAGED GRID OR LAY-IN PANELS. 2. INSTALL CEILING SYSTEMS IN A MANNER CAPABLE OF SUPPORTING ALL SUPERIMPOSED LOADS, WITH MAXIMUM PERMISSIBLE DEFLECTION OF 1/360 OF SPAN AND MAXIMUM SURFACE DEVIATION OF 1/8 INCH IN 10 FEET (1/960). 3. INSTALL AFTER MAJOR ABOVE-CEILING WORK IS COMPLETE. COORDINATE THE LOCATION OF HANGERS WITH OTHER WORK. ENSURE THE LAYOUT OF HANGERS AND CARRYING CHANNELS ARE LOCATED TO ACCOMMODATE FITTINGS AND UNITS OF EQUIPMENT WHICH ARE TO BE PLACED AFTER THE INSTALLATION OF CEILING GRID SYSTEM(S). 4. WHERE DUCTS OR OTHER EQUIPMENT PREVENT THE REGULAR SPACING OF HANGERS, REINFORCE THE NEAREST ADJACENT HANGERS AND RELATED CARRYING CHANNELS AS REQUIRED TO SPAN THE REQUIRED DISTANCE. 5. HANG INDEPENDENTLY OF WALLS, COLUMNS, DUCTS, PIPES, AND CONDUIT. WHERE CARRYING MEMBERS ARE SPLICED, AVOID VISIBLE DISPLACEMENT OF THE LONGITUDINAL AXIS OR FACE PLANE OF ADJACENT MEMBERS. 6. DO NOT SUPPORT FIXTURES FROM OR ON MAIN RUNNERS OR CROSS RUNNERS IF WEIGHT OF THE FIXTURE CAUSES THE TOTAL DEAD LOAD TO EXCEED THE DEFLECTION CAPABILITY. IN SUCH CASES, SUPPORT FIXTURE LOADS BY SUPPLEMENTARY HANGERS LOCATED WITHIN 6 INCHES OF EACH CORNER, OR SUPPORT THE FIXTURES INDEPENDENTLY. 7. INSTALL EDGE MOLDINGS AT INTERSECTION OF CEILING AND VERTICAL SURFACES USING MAXIMUM LENGTHS, STRAIGHT, TRUE TO LINE, AND LEVEL. MITER CORNERS. PROVIDE EDGE MOLDINGS AT JUNCTIONS WITH OTHER CEILING FINISHES. WHERE BULLNOSE CONCRETE BLOCK CORNERS OCCUR, PROVIDE PREFORMED CLOSERS TO MATCH EDGE MOLDING. 8. FIT ACOUSTIC LAY-IN PANELS IN PLACE, FREE FROM DAMAGED EDGES OR OTHER DEFECTS DETRIMENTAL TO APPEARANCE AND FUNCTION. FIT BORDER UNITS NEATLY AGAINST ABUTTING SURFACES. INSTALL PANELS IN ANY UNBROKEN AREA OF CEILING FROM THE SAME PRODUCT LOT AS INDICATED BY LOT NUMBER ON EACH CARTON. 9. INSTALL LAY-IN PANELS LEVEL IN UNIFORM PLANE AND FREE FROM TWIST, WARP, AND DENTS. SCALE: PROJECT NUMBER: DRAWING TITLE ISSUE / REVISION 51643 SOLARIS PLAZA 141 E MEADOW DRIVE #202 VAIL, CO 81657 SHEET NUMBER 10.26.16 PERMIT ISSUE 960 Atlantic Ave. Alameda, CA 94501 510 865 8663 mbharch.com 12.15.16 PLAN CHECK COMMENTS A10.02 ARCHITECTURAL SPECIFICATIONS AS NOTED 12/19/16