HomeMy WebLinkAboutB16-0481_A3.01_1482188422.pdf8 7 6 5 4 3 9
T
U
V
73'-6 1/8"
LEASELINE TO LEASELINE
30'-4"
LEASELINE TO LEASELINE
2
ADJACENT TENANT (N.I.C.)
ADJACENT TENANT (N.I.C.)
MALL EXIT
CORRIDOR (N.I.C.)
MALL EXTERIOR
E
L4 L4
F F F
X3
X3 X3
X3
M
X3
X3
X3
S
S
SHOWROOM / SALES
OFFICE
MALL EXIT
CORRIDOR (N.I.C.)
CL
1
2
(E) 9'-0" A.F.F.
SHOWROOM
(E) 10'-0" A.F.F.
SHOWROOM
(E) 10'-0" A.F.F.
SHOWROOM
3
EQ EQ EQ
EQ 3'-3"
TYP.
4
6
(E) 9'-6" A.F.F.
SHOWROOM
5 TYP.
7
SCALE:
1/4" = 1'-0" REFLECTED CEILING PLAN 2
A3.01
REFLECTED
CEILING PLAN
AS NOTED
REFLECTED CEILING PLAN KEY NOTES
1. FIELD VERIFY EXISTING SPRINKLER SYSTEM LAYOUT. INCLUDING MAIN TRUNKLINES, PIPING
ELEVATIONS & EXISTING CLEAR HEIGHTS.
2. REFER TO ELECTRICAL DRAWINGS FOR LIGHT FIXTURE SCHEDULE.
3. G.C. TO REPAIR ANY FIREPROOFING DISTURBED DURING CONSTRUCTION.
4. CENTER LIGHT IN TILE.
5. SEE STRUCTURAL DRAWINGS FOR STRUCTURAL DETAILS.
6. EXIT SIGNS SHALL BE CONNECTED TO AN EMERGENCY POWER SYSTEM THAT WILL PROVIDE AN
ILLUMINATION OF NOT LESS THAN 90 MIN. IN CASE OF PRIMARY POWER LOSS. (1011.2-1011.5.)
7. G.C. TO REUSE (E) SPEAKERS V.I.F. EXACT LOCATION & CONFIRM W/ OWNER CPM.
LIGHT FIXTURE LEGEND
TYPE DESCRIPTION
PENDANT MOUNTED WALL WASHER - COLOR BLACK, WHITE, OR SILVER
*L4 - WITH BAFFLE TO PREVENT SCALLOPING
EMERGENCY LIGHT
EM = EMERGENCY LIGHT
NL = NIGHT LIGHT OPERATION
(N) REFER TO DETAIL "L4" LIGHT FIXTURE MOUNTING
CEILING LEGEND NOTES
6
A8.03
SCALE:
PROJECT NUMBER:
DRAWING TITLE
ISSUE / REVISION
51643
SOLARIS PLAZA
141 E MEADOW DRIVE
#202
VAIL, CO 81657
SHEET NUMBER
10.26.16 PERMIT ISSUE
960 Atlantic Ave.
Alameda, CA 94501
510 865 8663
mbharch.com
12.15.16 PLAN CHECK COMMENTS
L4
X3
1
2
3
(E) EXIT SIGN.
X1
(E) SUPPLY GRILLE.
REFER TO MECHANICAL DRAWINGS.
(E) RETURN AIR GRILLE.
REFER TO MECHANICAL DRAWINGS.
MOTION SENSOR, WALL MOUNTED. REFER TO ELECTRICAL DRAWINGS.
SECURITY CAMERA, WALL MOUNTED. REFER TO ELECTRICAL DRAWINGS.
SPEAKERS. REFER TO ELECTRICAL DRAWINGS. REFER TO
(N) WALL MOUNTED SUPPLY GRILLE. REFER TO MECHANICAL DRAWINGS.
(E) SPRINKLER HEAD LOCATION, SHOWN FOR REFERENCE ONLY.
TYPE DESCRIPTION
S
SP
M
6
A8.03
SHOPPERTRAK
11
A8.03
SECURITY CAMERA, CEILING MOUNTED. REFER TO ELECTRICAL DRAWINGS.
S
1
A7.03
CONFIRM FIXTURE COLOR WITH TESLA DM.
REMOVE (E) TRACK LIGHT
(E) SURFACE MOUNT TRACK SYSTEM TO REMAIN
(N) EXIT SIGN, WALL MOUNTED
T1
F
FLUORESCENT LIGHTS
4 SEE MECHANICAL DWGS FOR SUPPLY AIR.
5 ALL (E) LIGHTING TO REMAIN. TYP U.O.N.
6 ALL (E) SPEAKERS TO REMAIN, GC TO WIRE INTO (N) SOUND SYSTEM CONTROLS
N
NOTE:
G.C. TO NOTIFY OWNER AND ARCHITECT
IF ANY DEVICE NOT ALREADY SHOWN ON
DRAWINGS NEEDS TO BE ADDED TO THE
SHOWROOM GYP. BD. WALLS, GYP. BD.
CEILINGS PRIOR TO INSTALLATION
7 (E) FIRE SPRINKLER VALVE ACCESS; 18" X 18" STEALTH ACCESS PANEL
E (E) EXIT SIGN
1
1
12/19/16