HomeMy WebLinkAboutB16-0481_A8.06_1482188426.pdfSUB FLOOR B.O. (E) STRUCTURE CEILING, SEE RCP 20 GA. METAL TRACK CONT. METAL BRIDGING, SEE 1 LAYER 5/8" TYPE "X" GYP. BD. ON 20 GA METAL STUDS @ 24" O.C. 20 GA. DIAGONAL METAL BRACING WHEN STUDS ARE GREATER THAN 14'-0" A.F.F. 2 - GYP. BD. EXTENSION ABOVE SUSPENDED CEILING ONLY. GYP. BD. EXTENSION TIGHT TO UNDERSIDE OF CONC. BEAM / OR SLAB+WEBS IN SALES AREA & OWNER'S LOUNGE T.O. FINISH FLOOR 6" 20 GA. METAL TRACK (N) xxxT150-43 TO MATCH SIZE OF STUDS (1) #10 SMS EACH SIDE @ EACH STUD HILTI X-U W/ 1 1/2" EMBED @ 48" OC AND @ 4" MIN/12" MAX FROM EACH END OF SILL TRACK, (2) MIN PER SILL TRACK SUB FLOOR B.O. (E) STRUCTURE CEILING, SEE RCP CONT. METAL BRIDGING, SEE 1 LAYER 5/8" TYPE "X" GYP. BD. EACH SIDE ON 20 GA METAL STUDS @ 24" O.C. 20 GA. METAL TRACK 2 -6" 20 GA. METAL TRACK GYP. BD. EXTENSION ABOVE SUSPENDED CEILING ONLY. T.O. FINISH FLOOR WHERE NO CEILING, EXTEND FULL HEIGHT (N) xxxT150-43 TO MATCH SIZE OF STUDS (1) #10 SMS EACH SIDE @ EACH STUD HILTI X-U W/ 1 1/2" EMBED @ 48" OC AND @ 4" MIN/12" MAX FROM EACH END OF SILL TRACK, (2) MIN PER SILL TRACK 1/2" NOTE: STORES IN SEISMIC ZONES 3 & 4 ONLY: PROVIDE CLIP ANGLE(S) + 5'-0" A.F.F. AT WALLS 10'-0" HIGH OR LESS, AND EVERY 4'-0" AT WALLS GREATER THAN 10'-0" OR AS REQUIRED BY LOCAL CODES. 1-1/2" X 3" X 16 GA. CHANNEL CLIP ANGLE 1/4" LESS THAN STUD WIDTH, TYP. - ATTACH AT EVERY STUD WITH (4) 5/8" #S-12 SCREWS OR 3/4" WELDS IN (3) PLACES MTL. STUD FRAMING, TYP. SEE WALL LEGEND - SHEET A2.01 FOR SIZE, GAUGE & SPACING 3/4" 16 GA. COLD-ROLLED CHANNEL, LOCATE AT 4'-0" O.C. HORIZONTALLY, OR AS REQUIRED BY LOCAL CODE TYP. AT ALL SITUATIONS INDICATED HERE: NESTED TRACKS (20 GAUGE MIN.) OR SLOTTED TRACK (20 GAUGE MIN.) TO ALLOW 1/2" DEFLECTION TRACKS PER ES REPORT ESR-1042 STUDS CUT 1/2" SHORT FOR 1/2" DEFLECTION FINISH MATERIALS (WHERE OCCURS) HELD 1/2" SHORT OF TOP OF TRACK TO ALLOW FOR 1/2" DEFLECTION. DO NOT SCREW FINISH MATERIALS INTO TOP OF TRACK - FASTEN INTO STUDS ONLY ACOUSTICAL SEALANT IN 1/2" DEFLECTION GAP AT PARTITIONS WITH ACOUSTICAL INSULATION CONCRETE SLAB (CAST-IN-PLACE OR POST-TENSIONED), TYP. THROUGHOUT THIS DETAIL HILTI X-U 0.157" DIAMETER POWDER-ACTUATED FASTENERS AT 18 O.C. EMBED 3/4" PER ESR-2269 6" X 3'-0" X 6" ANGLE LLH (20 GA MIN.) FASTEN BRACE TO ANGLE WITH (3) #10 SCREWS AT SINGLE BRACE: FASTEN ANGLE TO CONCRETE WITH (4) HILTI X-U 0.157" DIAMETER POWDER-ACTUATED FASTENERS, EMBED 3/4" PER ESR-2269 AT DOUBLE BRACE: FASTEN ANGLE TO CONCRETE WITH (5) HILTI X-U 0.157" DIAMETER POWDER-ACTUATED FASTENERS, EMBED 3/4" PER ESR-2269 TO TOP OF PARTITION PARTITION TO SLAB PARTITION BRACE TO SLAB A8.06 PARTITION DETAILS AS NOTED SCALE: 1-1/2" = 1'-0" NON-RATED PARTITION B SCALE: 1-1/2" = 1'-0" FURRED PARTITION A SCALE: PROJECT NUMBER: DRAWING TITLE ISSUE / REVISION 51643 SOLARIS PLAZA 141 E MEADOW DRIVE #202 VAIL, CO 81657 SHEET NUMBER 10.26.16 PERMIT ISSUE 960 Atlantic Ave. Alameda, CA 94501 510 865 8663 mbharch.com 12.15.16 PLAN CHECK COMMENTS SCALE: NOT USED D SCALE: 6" = 1'-0" TYPICAL BRIDGING DETAIL 2 SCALE: N.T.S. PARTITION TYPE LEGEND 1 X## FRAMING SIZE RATING/HR PARTITION TYPE PARTITION TYPE TAG PARTITION TYPE LEGEND: SEE PARTITION DETAILS THIS SHEET RATING LEGEND: 0 - NON-RATED PARTITION 1 - 1 HOUR RATED PARTITION 2 - 2 HOUR RATED PARTITION FRAMING SIZE LEGEND: 1 - 7/8" HAT CHANNEL 2 - 2 1/2" METAL FRAMING 3 - 3 5/8" METAL FRAMING 4 - 4" METAL FRAMING 6 - 6" METAL FRAMING GENERAL NOTES: 1. ALL METAL STUDS TO BE 20 GA. UNLESS NOTED OTHERWISE. 2. USE GREEN BOARD ON TILED WALLS. 3. LEVEL 4 GYP. BD. FINISH TYP. IN CUSTOMER FACING AREAS U.O.N. 4. LEVEL 5 FINISH AT FEATURE CEILING AND PLASMA WALL. SCALE: NOT USED E NOTE: SEE ELEVATIONS FOR BASE DETAIL. SCALE: NOT USED G SCALE:WALL HEIGHT TABLE 3 SCALE: 3" = 1'-0" CONCRETE DECK PARTITION - NON SEISMIC 6 12/19/16