HomeMy WebLinkAboutB16-0481_E100_1482188427.pdfSHEET # DRAWING TITLE DRAWING INDEX ELECTRICAL GENERAL INFORMATION E100 ELECTRICAL LIGHTING PLAN E200 GENERAL NOTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH 2014 NEC WITH LOCAL AMENDMENTS. REFER TO THE LATEST EDITION OF THE NEC, IECC, IBC AND LOCAL ORDINANCES IN EFFECT AT THE TIME OF CONSTRUCTION AS THE CONTROLLING DOCUMENTS. 2. ALL DEVICES AND EQUIPMENT INSTALLED OUTDOORS OR EXPOSED TO THE WEATHER SHALL BE OF WEATHERPROOF CONSTRUCTION. 3. ALL SINGLE AND GANGED PLATES SHALL BE THERMOPLASTIC AND SHALL MATCH THE DEVICE IN COLOR. COORDINATE DEVICE COLOR WITH THE ARCHITECT PRIOR TO INSTALLATION. GANG DEVICES AT GROUP LOCATIONS UNDER A SINGLE COVER PLATE. 4. THE ELECTRICAL PLANS ARE SCHEMATIC IN NATURE AND ARE NOT INTENDED TO SHOW ALL OF THE ARCHITECTURAL DETAIL OR SPECIFICS OF ELECTRICAL CONSTRUCTION. TAKE ALL DIMENSIONS FROM THE ARCHITECTURAL DRAWINGS. PRIOR TO ROUGH-IN, CONTRACTOR TO REVIEW ALL SUBMITTALS OF EQUIPMENT PROVIDED BY OTHER TRADE AND MAKE NECESSARY ADJUSTMENTS. 5. ALL CONNECTIONS TO MECHANICAL EQUIPMENT SHALL BE MADE WITH A MINIMUM OF 24" OF WEATHERPROOF FLEXIBLE CONDUIT TO PREVENT SOUND AND VIBRATION TRANSMISSION TO THE STRUCTURE. 6. COORDINATE ALL MOTOR OVERLOADS AND/OR FUSES FURNISHED BY THIS CONTRACT WITH THE ACTUAL EQUIPMENT INSTALLED. SIZE OVERLOADS BASED ON MOTOR NAMEPLATE FULL LOAD CURRENT AND SERVICE FACTOR. FUSES FOR MOTOR AND TRANSFORMER CIRCUITS SHALL BE DUAL ELEMENT. FUSES FOR OTHER "NON-INRUSH" LOADS SHALL BE FAST ACTING. ALL FUSES SHALL BE CURRENT LIMITING CLASS RK5 OR CLASS L UNLESS OTHERWISE NOTED. FUSES SHALL BE PROVIDED WITH REJECTION TYPE FUSE HOLDERS. 7. GROUNDING CONDUCTORS ARE GENERALLY NOT SHOWN. GROUND AND BOND TOGETHER ALL EQUIPMENT, RACEWAYS, MOTORS, PANELBOARDS AND SWITCHBOARDS, ETC. IN ACCORDANCE WITH NEC ARTICLE 250. BONDING OF ALL INTERIOR METAL PIPING SHALL BE IN ACCORDANCE WITH NEC ARTICLE 250 AS FOLLOWS: A. ALL INTERIOR METAL WATER PIPING SHALL BE BONDED TO ONE OR MORE GROUNDING ELECTRODES USED. THE BONDING JUMPER SHALL BE SIZED IN ACCORDANCE WITH NEC ARTICLE 250. B. INTERIOR METAL PIPING THAT MAY BECOME ENERGIZED (i.e. GAS PIPING, ETC.), SHALL BE BONDED TO ONE OR MORE GROUNDING ELECTRODES USED. THE BONDING JUMPER SHALL BE SIZED IN ACCORDANCE WITH NEC ARTICLE 250, USING THE RATING OF THE CIRCUIT THAT MAY ENERGIZE THE PIPING SYSTEM. C. INTERIOR METAL PIPING SYSTEM SEPARATED BY A PLUMBING EQUIPMENT (I.E. METER, WATER HEATER) SHALL BE PROVIDED WITH A BONDING JUMPER SIZED PER NEC ARTICLE 250. ALL GROUNDING ELECTRODE INSTALLED IN THE BUILDING (SINGLE OR MULTIPLE SERVICES) SHALL BE BONDED TOGETHER TO FORM A SINGLE GROUNDING ELECTRODE SYSTEM 8. INSTALL ALL WALL MOUNTED POWER, TELEPHONE AND DATA OUTLETS AT +15" A.F.F. TO BOTTOM OF THE BOX, UNLESS OTHERWISE NOTED. INSTALL ALL LIGHTING CONTROL SWITCHES, FIRE ALARM PULLSTATIONS, AND WALL TELEPHONE JACKS AT +48" A.F.F. TO TOP OF THE BOX, UNLESS OTHERWISE NOTED. 9. CONDUCTOR PENETRATION OF FIRE RATED PORTIONS OF A STRUCTURE SHALL BE EFFECTIVELY SEALED AND SLEEVED WITH STEEL FLEX 3 FEET EACH SIDE OF THE PENETRATION, OR OTHER APPLIED METHODS. 10. RECESSED LIGHT FIXTURES INSTALLED WHERE THERE ARE INSULATION IS REQUIRED TO BE I.C. RATED. ALL LIGHT SWITCHES NOT WITHIN SIGHT OF THE LUMINAIRES SHALL BE EQUIPPED WITH A PILOT LIGHT, EVEN IF NOT SHOWN IN THE DRAWINGS. CONTRACTOR TO PROVIDE ALL REQUIRED SEISMIC SUPPORT WIRES FOR THE LIGHTING FIXTURES. PENDANT FIXTURES SHALL BE PROVIDED WITH SEISMIC SUPPORT WIRES SO AS NOT TO HIT ANYTHING ON A 45 DEGREE SWING AND AS REQUIRED NY THE AHJ. 11. ALL EQUIPMENT SHALL BE UL LISTED AND SHALL BE INSTALLED AS PER THEIR LISTINGS. INSTALLATION INSTRUCTION FOR ALL UL LISTED EQUIPMENT SHALL BE MADE AVAILABLE TO THE BUILDING INSPECTOR AT THE TIME OF INSPECTION. ALL DEVICES AND EQUIPMENT INSTALLED OUTDOORS OR EXPOSED TO THE WEATHER SHALL BE OF WEATHERPROOF CONSTRUCTION. ALL RECEPTACLES SHALL COMPLY WITH THE LATEST EDITION OF THE N.E.C., EVEN IF NOT SPECIFICALLY IDENTIFIED IN THE DRAWINGS (GFCI, AFCI, TAMPER RESISTANT, HOSPITAL GRADE, ETC.) 12. STRUCTURAL STEEL FIREPROOFING THAT WERE DAMAGED DURING CONSTRUCTION SHALL BE PATCHED AND REPAIRED BY THIS CONTRACTOR. 13. NO FLEXIBLE CONDUIT IS PERMITTED IN DEMISING WALLS. FLEXIBLE CONDUIT IS PERMITTED FOR SHORT, FINAL CONNECTIONS ONLY (6'-0" OR LESS). 14. EXPOSED CONDUIT SHALL BE INSTALLED IN STRAIGHT LINES, PARALLEL OR IN RIGHT ANGLES TO THE BUILDING STRUCTURE. DO NOT LOOP EXCESS FLEXIBLE CONDUIT IN CEILING SPACE OR WALL CAVITY. 15. CABLE TYPES AC AND NM CABLES ARE NOT ACCEPTABLE. TYPE MC CABLE, ELECTRIC METALLIC TUBING (EMT) AND RIGID GALVANIZED CONDUIT ARE PERMITTED. 16. ALL ELECTRICAL PANELS TO BE UL LABELED WITH BOLT ON TYPE CIRCUIT BREAKERS. ELECTRICAL PANELS MAY NOT BE RECESSED IN DEMISING PARTITIONS. SURFACE MOUNT OF FUR OUT WALL TO ACHIEVE FLUSH FINISH APPEARANCE. PANELS SHALL BE MOUNTED ON PLYWOOD BACKER BOARD. 17. 7 DAY, 24 HOUR TIME CLOCK IS REQUIRED TO CONTROL STOREFRONT ENTRY LIGHTS, SHOW WINDOW LIGHTS, SHOW WINDOW RECEPTACLES AND STOREFRONT SIGNAGE. ILLUMINATED STOREFRONT SIGNS MUST REMAIN LIT DURING ALL MALL BUSINESS HOURS. 18. CONTRACTOR IS REQUIRED TO MAKE A FIELD SURVEY OF THE EXISTING ELECTRICAL SERVICE TO ENSURE THAT THE TOTAL CONNECTED LOAD DOES NOT EXCEED THE ELECTRICAL SERVICE. ANY/ ALL MODIFICATIONS OR UPGRADES NEEDED ARE SUBJECT TO LANDLORD'S PRIOR APPROVAL, AND WILL BE COMPLETED BY TENANT/ TENANT'S GC, AT TENANT'S SOLE EXPENSE. 19. COORDINATE ALL CONCRETE TRENCHING/ CORING TO ENSURE THAT ANY UNDER SLAB UTILITIES, ETC., ARE NOT DAMAGED DURING FLOOR CUT. ANY DAMAGE TO BE REPAIRED AT TENANT EXPENSE. PRIOR APPROVAL AND COORDINATION WITH PROPERTY MANAGEMENT IS REQUIRED FOR ALL CONCRETE CUTTING. 20. PROVIDE UPSIZED CONDUCTORS TO COMPENSATE FOR VOLTAGE DROP, FOR 12A LOAD, 120V CIRCUIT: USE #10 FOR 76'-125' RUN, USE #8 FOR 126'-175' RUN, USE #6 FOR 176'-225' RUN. ELECTRICAL POWER PLAN E300 E600 ELECTRICAL SPECIFICATIONS E601 ELECTRICAL SPECIFICATIONS E400 ELECTRICAL ONE-LINE DIAGRAM AND PANEL SCHEDULES GROUNDING ELECTRODE SYSTEM: UFER, GROUND ROD, U.G. WATER PIPE, STRUCTURAL STEEL. CIRCUIT BREAKER E100 ELECTRICAL GENERAL INFORMATION ABBREVIATION DESCRIPTION SYMBOL WEATHERPROOF WP UNLESS NOTED OTHERWISE U.N.O. U.O.N. SEE PLUMBING DRAWINGS S.P.D. PHASE PH NIGHT LIGHT, "ON" 24/7 NL GROUND FAULT INTERRUPTER GFI ABOVE FINISHED FLOOR AFF EXHAUST FAN EF VOLTAGE DROP VD AMPERE A MAIN CIRCUIT BREAKER MCB MAIN LUG ONLY MLO AMPERE INTERRUPTING CAPACITY AIC SEE MECHANICAL DRAWINGS S.M.D. SEE ARCHITECTURAL DRAWINGS S.A.D. EMERGENCY EM SUBSCRIPT LOCATED NEXT TO THE DEVICE MEANS 42"AFF TO CENTER OF DEVICE +42 NATIONAL ELECTRICAL CODE NEC RIGID METAL CONDUIT RMC AMERICAN WIRE GAUGE AWG CONDUIT C VARIABLE FREQUENCY DRIVE VFD COPPER CU GROUND G, GND FURNISH, INSTALL, CONNECT PROVIDE POLE P VOLTS V VOLT AMPERE VA SHORT CIRCUIT CURRENT ISC ONE WAY DISTANCE OF FEEDER/ BRANCH CIRCUIT D REMOVE, DEMO (R) EXISTING (E) EXISTING TO BE RELOCATED (RE) RELOCATED TO THIS NEW LOCATION (RL) PROVISION FOR FUTURE METER PFM PROVISION FOR FUTURE BREAKER PFB LEGEND DESCRIPTION SYMBOL 15A WALL MOUNTED DUAL TECH (U.N.O.) OCCUPANCY OR VACANCY SWITCH SENSOR. LOWER CASE LETTER INDICATES CIRCUIT CONTROLLED BY SWITCH. HORSEPOWER RATED TOGGLE SWITCH WITH THERMAL OVERLOADS. 20A THREE WAY SWITCH AND BOX WALL MOUNTED 1P, 20A SWITCH AND BOX. LOWER CASE LETTER INDICATES CIRCUIT CONTROLLED BY SWITCH. ab 3 T ab DIMMER SWITCH, VA RATING AS SHOWN AND AS REQUIRED DUPLEX OR QUAD CONVENIENCE OUTLET: 20AMP, 120V STANDARD - WHITE = PASS & SEYMOUR #CRB5362-W "B" - BLACK = PASS & SEYMOUR #CRB5362-B "R" - RED = PASS & SEYMOUR #CRB5362-R CONTROLLED OUTLET: 20AMP, 120V, SPLIT-WIRED: PASS & SEYMOUR #5362CH-X 20AMP, 120V, DUAL-CONTROLLED: PASS & SEYMOUR #5362CD-X R R B B SIMPLEX RECEPTACLE, NEMA CONFIGURATION AS NOTED. "B" - BLACK. SPECIAL RECEPTACLE, NEMA CONFIGURATION AS NOTED. "B" - BLACK. FLUSH FLOOR MOUNTED OUTLET BOX WITH DUPLEX RECEPTACLE. SEE FLOOR PLAN FOR SPEC. FLUSH CEILING MOUNTED OUTLET BOX WITH DUPLEX OR QUAD RECEPTACLE. "C" INDICATES FLUSH MOUNTED IN CEILING. C C DATA OUTLET DEVICE BOX. PROVIDE 3/4" CONDUIT INTO CEILING SPACE. PROVIDE ELBOW, BUSHING AND PULL STRING. TELEPHONE OUTLET DEVICE BOX. PROVIDE 3/4" CONDUIT INTO CEILING SPACE. PROVIDE ELBOW, BUSHING AND PULL STRING. AP CEILING MOUNTED DATA OUTLET (REFER TO VENDOR DRAWINGS): "AP" - ACCESS POINT "ST" - SHOPPER TRAK ST JUNCTION BOX - WALL OR CEILING MOUNTED NON-FUSED DISCONNECT SWITCH. FUSED DISCONNECT SWITCH WITH DUAL ELEMENT FUSES PER EQUIPMENT NAME PLATE RATING. MAGNETIC MOTOR STARTER. COMBINATION MAGNETIC MOTOR STARTER AND DISCONNECT SWITCH. MOTOR OUTLET AND FLEX CONNECTION TO MOTOR. HOMERUN TO PANEL INDICATING CIRCUIT NUMBERS. ALL WIRING SHALL BE #12 AWG WITH GROUND WIRE IN 3/4" U.O.N. CONSULT VOLTAGE DROP TABLE FOR MAXIMUM DISTANCE. T TRANSFORMER WITH REQUIRED GROUNDING. SIZE, VOLTAGE, TYPE AS PER PLANS. SWITCH & FUSE PANELBOARD SURFACE OR FLUSH MOUNTED. SIZE, VOLTAGE, TYPE AS PER PLANS. FACP FIRE ALARM CONTROL PANEL, TOP OF PANEL AT +6'-0" A.F.F. F A V AV xx xx FIRE ALARM MANUAL PULL STATION, +48" AFF. TO TOP OF OPERABLE HANDLE, UON. FIRE ALARM HORN, MOUNTED AT +90" AFF. TO TOP OF DEVICE, UON. FIRE ALARM STROBE LIGHT, +90" AFF. TO TOP OF THE LENS "xx" INDICATES CANDELA RATING. FIRE ALARM HORN/STROBE COMBINATION, +90" AFF. TO TOP OF THE LENS, UON. "xx" INDICATES CANDELA RATING. HVAC SMOKE DUCT DETECTOR, S.M.D. LINE-VOLTAGE THERMOSTAT, S.M.D. T SECURITY CAMERA, REFER TO PLANS. M MOTION SENSOR LOCATION: COORDINATE WITH SECURITY CONTRACTOR. PROVIDE DEVICE BACKBOX AND 3/4" CONDUIT WITH NYLON BUSHING STUBBED INTO ACCESSIBLE CEILING SPACE. SEE GENERAL NOTE S9. SECURITY DEVICE LOCATION: SEE SECURITY VENDOR DRAWINGS. PROVIDE DEVICE BACKBOX AND 3/4" CONDUIT WITH NYLON BUSHING STUBBED INTO ACCESSIBLE CEILING SPACE. "CR" - CARD READER. "KP" - KEYPAD. GENERAL CONTRACTOR GC FIRE ALARM DESIGN BUILD NOTES 1. FIRE ALARM (FA) SYSTEM SHALL BE DESIGNED BY A LANDLORD APPROVED FA SYSTEM CONTRACTOR. THE FA CONTRACTOR SHALL PRODUCE DRAWINGS, EQUIPMENT CUT SHEETS, ETC. PER LOCAL CODE, LOCAL CITY FIRE DEPARTMENT, NEC AND NFPA72 REQUIREMENTS. SUBMIT TO THE LOCAL AUTHORITIES HAVING JURISDICTION AND OWNER'S INSURANCE COMPANY FOR APPROVAL PRIOR TO ORDERING EQUIPMENT. 2. LANDLORD WILL STUB-OUT INTO TENANT'S SPACE A CONDUIT WITH ALARM WIRE AND A J-BOX, FOR CONNECTION TO MALL'S FA SYSTEM. 3. NEW FA SYSTEM SHALL MEET MINIMUM REQUIREMENTS OF MALL AND SHALL BE CONNECTED TO THE MALL'S FA MONITORING SYSTEM. 4. ALL PANELS, PERIPHERAL DEVICES AND MATERIALS SHALL BE STANDARD PRODUCT OF SINGLE MANUFACTURER AND SHALL DISPLAY THE MANUFACTURER'S NAME ON EACH COMPONENT. DEVICES AND MATERIALS SHALL BE COMPATIBLE WITH LANDLORD'S MAIN SYSTEM. 5. GC TO OBTAIN QUOTE FROM THE LL DESIGNATED FA CONTRACTOR AND ENGAGE HIS SERVICES. INCLUDE IN BID ALL COSTS FOR PERMITS AND FEES, IF APPLICABLE. DEMOLITION NOTES 1. WHERE REMOVAL OF AN EXISTING WORK (I.E., OUTLET, CONDUIT, WIRING ETC.) WILL RESULT IN LOSS OF CIRCUIT CONTINUITY, THE REMAINING ISOLATED PORTIONS OF THE CIRCUIT SHALL BE RECONNECTED TO THE NEAREST AVAILABLE AND APPROPRIATE EXISTING OUTLETS. 2. WHERE EXISTING WIRING OR EQUIPMENT IS TO BE ABANDONED, IT SHALL BE REMOVED AND THIS WORK SHALL INCLUDE BUT NOT LIMITED TO THE FOLLOWING: A. REMOVE WIRES AND CABLES B. REMOVE AND RELOCATE LIGHTING FIXTURES C. REMOVE DEVICES AND EQUIPMENT D. REMOVE EXPOSED CONDUITS E. CUT OFF & CAP ABANDONED CONDUIT; STUBS SHALL NOT EXTEND ABOVE FLOOR F. REMOVE OTHER ITEMS NOT INCLUDED IN ITEMS (A) THRU (D) 3. WHERE EXISTING WIRING, DEVICES AND EQUIPMENT ARE REMOVED, SUCH ITEMS SHALL NOT BE RE-USED UNLESS SPECIFICALLY DIRECTED AND APPROVED BY OWNER. 4. REFER TO DEMOLITION NOTES ON ARCHITECTURAL DRAWINGS, REGARDING EXISTING LIGHT FIXTURES. 5. REROUTE ALL CONDUITS THAT ARE TO REMAIN IN SERVICE AND WHICH CONFLICT WITH EQUIPMENT INSTALLATION. 6. WHEREVER EXISTING ELECTRICAL DEVICES, CONDUITS, CABLES, OR OTHER ITEMS CONFLICT WITH REMODEL WORK, WHETHER SHOWN OR NOT, RELOCATE THESE ITEMS. 7. PATCH AND PAINT TO MATCH EXISTING, IN ALL AREAS AFFECTED BY REMOVAL OF ELECTRICAL EQUIPMENT AND DEVICES. 8. DISCONNECT AND REMOVE ALL EXISTING ELECTRICAL DEVICES IN EXISTING CEILINGS AND WALLS WHICH ARE REQUIRED TO BE DEMOLISHED, WHETHER SHOWN OR NOT. MAINTAIN CIRCUITS TO ALL REMAINING DEVICES. ITEM # FURNISHED BY INSTALLED BY C O N T R A C T O R O W N E R C O N T R A C T O R DESCRIPTION SWITCHBOARDS, PANELBOARDS, TRANSFORMERS, CIRCUIT BREAKERS, FUSES, SAFETY SWITCHES. LIGHTING FIXTURES (INTERIOR, EXTERIOR). LIGHTING CONTROL SYSTEM TELECOM PATHWAYS, BOXES, CONDUITS. TELECOM DEVICES, SERVER EQUIPMENTS. O W N E R V E N D O R O W N E R V E N D O R SECURITY SYSTEM. O W N E R EXTERIOR LIGHTING SIGNAGE. ELECTRICAL WIRING PROVISION FOR MECHANICAL & PLUMBING EQUIPMENTS. ALL OTHERS. RECEPTACLES, N14-50R's. MATRIX RESPONSIBILITY E500 ELECTRICAL LIGHTING FIXTURE SCHEDULE & COMPLIANCE FORMS DUPLEX OR QUAD CONVENIENCE OUTLET: 20AMP, 120V ABOVE COUNTER. SEE ARCHITECTURAL ELEVATIONS FOR EXACT HEIGHT. DUPLEX OR QUAD CONVENIENCE OUTLET: 20AMP, 120V, GFCI STANDARD - WHITE = PASS & SEYMOUR #2095W SCALE: PROJECT NUMBER: DRAWING TITLE ISSUE / REVISION 51643 SOLARIS PLAZA 141 E MEADOW DRIVE #202 VAIL, CO 81657 SHEET NUMBER 10.26.16 PERMIT ISSUE 960 Atlantic Ave. Alameda, CA 94501 510 865 8663 mbharch.com 3371 Olcott Street Copyright c 2016 info@acies.net fx: (408) 522-5260 ph: (408) 522-5255 Santa Clara, CA 95054 ENGINEERING EXP: 10/31/17 12.15.16 PLAN CHECK COMMENTS 12/19/16