HomeMy WebLinkAboutB16-0481_E200_1482188427.pdfL202-13 6 L202-17 L202-17 L202-17 L202-17 L202-17 L202-17 L202-17 (E) (E) (E) (E) a a b L202-17 6 6 6 6 6 6 (E) 8 7 6 5 4 3 9 2 ADJACENT TENANT (N.I.C.) MALL EXIT CORRIDOR MALL EXTERIOR X1 L4 L4 F F F X3 X3 X3 X3 X3 X3 X3 9 -EM LV (RL) PANEL L202 k,m n,p r,s x,y 1/k3/m5/n7/p 9/r 11/s21/x 23/y w w 7 a,b 17/w (E) LIGHTING SWITCHBANK 8A 8B LCP 1 2 2 3 LV 8 9 T L202-41 4 5 SCALE: 1/4" = 1'-0" FLOOR PLAN - LIGHTING 1 SCALE: NONE LIGHTING CONTROL PANEL SCHEDULE 2 1. SEE SHEET E100, GENERAL NOTES. 2. MOUNTING TYPES INDICATED FOR EXIT LIGHTS (WALL, CEILING, ETC.) ARE INTENDED TO BE DIAGRAMMATIC ONLY TO INDICATE REQUIRED LOCATIONS. ELECTRICAL CONTRACTOR SHALL PROVIDE SPECIFIC TYPES OF MOUNTING HARDWARE AS REQUIRED BY FIELD CONDITIONS. 3. IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO DETERMINE THE TYPE OF CONSTRUCTION INTO WHICH EACH LIGHTING FIXTURE WILL BE INSTALLED AND TO FURNISH THE APPROPRIATE MOUNTING HARDWARE AND ACCESSORIES. 4. EXPOSED RACEWAYS SUPPLYING LIGHTING FIXTURES (AND ALL OTHER ITEMS) SHALL BE INSTALLED PARALLEL OR PERPENDICULAR TO BUILDING WALLS. WHERE OFFSETS, "KICKS", ETC. ARE REQUIRED TO AVOID OBSTACLES, THESE SHALL BE DONE IN A WORKMANLIKE MANNER WITHOUT KINKS, "DOGLEGS", ETC. 5. INSTALLATION OF LIGHTING FIXTURES SHALL BE CAREFULLY COORDINATED WITH ARCHITECTURAL AND MECHANICAL DRAWINGS TO AVOID CONFLICTS WITH DUCTWORK, ARCHITECTURAL FEATURES, ETC. WHERE CONFLICTS ARISE, CLARIFY WITH ARCHITECT PRIOR TO PROCEEDING WITH INSTALLATION. 6. BASED ON LIGHTING MANUFACTURERS PUBLISHED DATA, EMERGENCY BATTERY LIGHTS ARE LOCATED TO PROVIDE ONE (1) FOOT CANDLE ALONG THE MEANS OF EGRESS. 7. THIS CONTRACTOR SHALL MEET IN THE FIELD WITH FIRE INSPECTOR TO AIM AND ADJUST EMERGENCY LIGHTS AS HE DEEMS NECESSARY. CONTRACTOR SHALL ADD ADDITIONAL BATTERY LIGHTS AND EXIT SIGNS WERE THE FIRE INSPECTOR MANDATES. 8. WIRE EMERGENCY LIGHTING BATTERY PACKS, BATTERY BACKUP EXIT SIGNS AND NIGHT LIGHTS INDICATED TO LOCAL LIGHTING CIRCUIT AHEAD OF ALL LOCAL SWITCHING. 9. PROVIDE APPROVED HANDLE TIE FOR ALL MULTIWIRE BRANCH CIRCUITS AS REQUIRED PER NEC ART. 210.4(B). 10. PROVIDE LINEAR DISCONNECT FOR THOSE FIXTURES EMPLOYING DOUBLE-ENDED FLUORESCENT LAMPS PER NEC 410.130(G). 11. AIM AND ADJUST ALL LIGHT FIXTURES AS PER ARCHITECTURAL PLANS. WIRE THROUGH RELAY IN LIGHTING CONTROL PANEL "LCP" FOR CONTROL BY TIME CLOCK FOR "GC - GENERAL CLEANING" LIGHTING CONTROL. WIRE THROUGH RELAY IN LIGHTING CONTROL PANEL "LCP" FOR CONTROL BY TIME CLOCK FOR "SO - STORE OPENING" LIGHTING CONTROL. PROVIDE LIGHTING CONTROL PANEL AND LIGHTING CONTACTORS IN A NEMA-1 ENCLOSURE. SEE DETAIL ON THIS SHEET FOR MORE INFORMATION. WIRE THROUGH RELAY IN LIGHTING CONTROL PANEL "LCP" FOR CONTROL BY TIME CLOCK FOR "SN - SIGN" LIGHTING CONTROL. LED EXTERIOR SIGN TO BE PROVIDED BY OTHERS. CONTRACTOR SHALL REFER TO VENDOR DRAWINGS FOR EXACT WIRING REQUIREMENTS AND ROUGH IN. EMERGENCY FIXTURE SHALL BE WIRED WITH LOCAL LIGHTING CIRCUIT AHEAD OF ALL SWITCHING DEVICES. EMERGENCY LIGHT SHALL BE WIRED AS A SWITCHED FIXTURE. INTEGRAL BATTERY PACK SHALL BE WIRED HOT AHEAD OF SWITCHING PER MANUFACTURERS SPECIFICATIONS SO THAT EMERGENCY LIGHTS COMES ON IN A POWER FAILURE REGARDLESS OF SWITCHING. LOCATION OF LOW VOLTAGE OVERRIDE SWITCH. VERIFY EXACT LOCATION WITH OWNER PRIOR TO ROUGH-IN. SEE DETAIL ON THIS SHEET FOR MORE INFORMATION. EXISTING LOCATION OF TRACK LIGHTING CONTROLS. CONFIRM REQUIREMENTS WITH OWNER AND RELOCATE TO NEW LOCATION AS REQUIRED. INTERCEPT AND EXTEND ALL CIRCUITS TO RELOCATED PANEL L202 LOCATION. ROUTE ALL LIGHTING CIRCUITS VIA TIME-CLOCK AND LIGHTING CONTACTORS. SEE DETAIL ON THIS SHEET FOR MORE INFORMATION. REPLACE EXISTING DIMMER SWITCH WITH NEW ON/OFF SWITCH. INTERCEPT AND EXTEND CIRCUIT TO RELOCATED PANEL L202 LOCATION. ROUTE CIRCUIT VIA TIME-CLOCK AND LIGHTING CONTACTOR. SEE DETAIL ON THIS SHEET FOR MORE INFORMATION. CEILING MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR WITH COMPATIBLE REMOTE POWERPACK. HUBBELL CAT. #OMNI-DT SERIES WITH #UNVPP POWERPACK. PROVIDE WITH COMPATIBLE LOW-VOLTAGE MOMENTARY SWITCHES FOR 50% AUTO - 50% MANUAL ON/AUTO OFF OPERATION. FIELD VERIFY EXACT MOUNTING LOCATION AND HEIGHT FOR MAXIMUM COVERAGE. 1 2 3 4 5 6 7 8 8B SHEET GENERAL NOTES SHEET KEYED NOTES SCALE: NONE SHEET NOTES 2 1. LIGHT FIXTURES AUTOMATICALLY TURN ON PER SCHEDULE. 2. LIGHTS AUTOMATICALLY SHUT OFF AT THE END OF SCHEDULED HOURS. 3. DURING NON-BUSINESS HOURS, PRESSING THE LV SWITCH ACTIVATES CORRESPONDING LIGHT FIXTURES FOR MAXIMUM OF 2 HOURS. LIGHTS WILL FLICKER 5-10 MINUTES PRIOR TO SCHEDULED SHUT-OFF. SEQUENCE OF OPERATIONS "STAFF" IS DEFINED: MONDAY THROUGH SATURDAY - 5:45AM UNTIL 11:15 PM SUNDAY - 8:45AM UNTIL 8:15PM "SIGNAGE" IS DEFINED: DUSK TO DAWN. "CUSTOMER" IS DEFINED: MONDAY THROUGH SATURDAY - 9:45AM UNTIL 9:15PM SUNDAY - 11:45AM UNTIL 6:15PM STORE BUSINESS HOURS(*) 1. LIGHTING CONTROL PANEL SHALL BE HUBBELL CX4 OR APPROVED EQUAL. 2. PROVIDE COMPATIBLE LOW-VOLTAGE SWITCH WITH PILOT LIGHT, HUBBELL LVSMXPL OR EQUAL. 3. CONSULT WITH OWNER FOR STORE BUSINESS HOURS PRIOR TO PROGRAMMING. 4. LIGHTING CONTROL SYSTEM IS FURNISHED BY OWNER VENDOR AND TO BE INSTALLED BY CONTRACTOR, UON. REFER TO MANUFACTURER WIRING DIAGRAM AND INSTALLATION INSTRUCTIONS FOR MORE INFORMATION. DETAIL NOTES CP1 CP2 E200 ELECTRICAL LIGHTING PLAN AS NOTED SCALE: PROJECT NUMBER: DRAWING TITLE ISSUE / REVISION 51643 SOLARIS PLAZA 141 E MEADOW DRIVE #202 VAIL, CO 81657 SHEET NUMBER 10.26.16 PERMIT ISSUE 960 Atlantic Ave. Alameda, CA 94501 510 865 8663 mbharch.com 3371 Olcott Street Copyright c 2016 info@acies.net fx: (408) 522-5260 ph: (408) 522-5255 Santa Clara, CA 95054 ENGINEERING EXP: 10/31/17 12.15.16 PLAN CHECK COMMENTS 8A 9 1 1 12/19/16