HomeMy WebLinkAboutB16-0481_E400_1482188429.pdfSCALE: NONE PARTIAL ONE-LINE DIAGRAM 1 1. ALL ELECTRICAL EQUIPMENTS AND FEEDERS ARE "(E)", EXISTING UNLESS OTHERWISE NOTED AS "(N)" FOR NEW. RE-TORQUE ALL EXISTING TERMINATIONS PER MANUFACTURER RECOMMENDATION. 2. SWITCHBOARD SHOWN ON THE SINGLE LINE DIAGRAM SHALL BE "FULLY-RATED" ADEQUATE FOR THE MAXIMUM FAULT CURRENT AVAILABLE AT THE POINT OF APPLICATION, INCORPORATING THE CURRENT LIMITING DEVICES AS SPECIFIED. "SERIES-RATING" FOR PANELBOARDS IS ACCEPTABLE. PROVIDE REQUIRED MARKING AS REQUIRED PER NEC ARTICLE 110.22(B) & (C) FOR SIGNAGE AT ALL PANELS AND EQUIPMENT. IF NOT "FULLY-RATED SYSTEM" CONTRACTOR SHALL SUBMIT SHOP DRAWINGS INDICATING SERIES RATING AND INCLUDE A COPY OF ALL LABELING, INCLUDING RESPECTIVE UL LISTING, TO THE AHJ FOR REFERENCE. 3. ALL PANELS SHALL BE PAINTED TO MATCH ADJACENT WALL FINISH (VERIFY WITH ARCHITECT PRIOR TO PAINTING). PROVIDE PHENOLIC NAMEPLATE LABELLING & PANEL DIRECTORY FOR ALL PANELS (EXISTING OR NEW). 4. INTERIOR METAL PIPING SYSTEM SHALL BE BONDED TO THE GROUNDING ELECTRODE SYSTEM. 5. GROUND AND NEUTRAL SHALL ONLY BE BONDED AT THE SERVICE EQUIPMENT AND AT THE SEPARATELY DERIVED SYSTEM. 6. CONTRACTOR TO VERIFY THE INTEGRITY OF THE EXISTING GROUNDING ELECTRODE SYSTEM AND SUBMIT FINDINGS TO ELECTRICAL ENGINEER FOR REVIEW. 7. THE INSULATION OF THE SPECIFIED CONDUCTORS SHALL BE THWN-2, XHHW-2 OR THHN. DETAIL NOTES: DETAIL KEYED NOTES: RELOCATE EXISTING PANEL L202 TO NEW LOCATION AS SHOWN ON SHEET E300. INTERCEPT AND EXTEND ALL EXISTING CIRCUITS TO NEW PANEL LOCATION. EXISTING (2) SETS OF 2-1/2" C. STUBBED INTO TENANT SPACE. FIELD VERIFY EXACT LOCATION. INTERCEPT AND EXTEND EXISTING 4#4/0 + 1#4GND IN 2-1/2"C FOR FEEDER SERVING PANEL TO NEW LOCATION. A SCALE: NONE PANEL SCHEDULES 2 E400 ELECTRICAL PARTIAL ONE-LINE & PANEL SCHEDULES N.T.S. B C ELECTRICAL CONTRACTOR SHALL INVESTIGATE THE EXISTING CONDITIONS AND FUNCTIONALITY OF THE EXISTING PANELS AND TRANSFORMER TO BE RELOCATED IN THIS SCOPE OF WORK, AND SHALL PROVIDE A BID ALTERNATE FOR REPAIRING OR REPLACING NON-FUNCTIONAL AND/OR DEFECTIVE EQUIPMENT. BID ALTERNATE NOTE: SCALE: PROJECT NUMBER: DRAWING TITLE ISSUE / REVISION 51643 SOLARIS PLAZA 141 E MEADOW DRIVE #202 VAIL, CO 81657 SHEET NUMBER 10.26.16 PERMIT ISSUE 960 Atlantic Ave. Alameda, CA 94501 510 865 8663 mbharch.com 3371 Olcott Street Copyright c 2016 info@acies.net fx: (408) 522-5260 ph: (408) 522-5255 Santa Clara, CA 95054 ENGINEERING EXP: 10/31/17 12.15.16 PLAN CHECK COMMENTS (E) TENANT DISTRIBUTION DSL-A: 2000A, 3PH, 4W, 208/120V, 65K AIC (E) 200A 3P (E) A B 12/19/16