Loading...
HomeMy WebLinkAboutB16-0481_M500_1482188451.pdfM500 MECHANICAL DETAILS N.T.S. NTS 3 NTS 6 NTS 2 NTS 1 NTS 10 NTS 7 NOT USED 8 NTS 9 NTS 11 NTS NTS 12 DUCT SUPPORT DIA. (IN) MAXIMUM SPACING WIRE DIA. ROD STRAP 6-10 11-18 19-24 12' 12' 12' ONE 12 GA. TWO 12 GA. TWO 10 GA. OR ONE 8 GA. 1/4" 1/4" 1/4" 1" X 22 GA. 1" X 22 GA. 1" X 22 GA. STRAP WIRE OR ROD 1/4" 270 LBS 3/8" 680 LBS 0.162" 160 LBS 1" X 22 GA. - 260 LBS 1" X 20 GA. - 260 LBS 0.106" 80 LBS 0.135" 80 LBS (10 GA.) (12 GA.) 1" X 18 GA. - 420 LBS 1" X 16 GA. - 700 LBS 1-1/2" X 16 GA. - 1100 LBS NOTES: 1 REFER TO SPECIFICATIONS FOR HANGER SPACINGS. 2 ATTACHMENTS TO OVERHEAD STRUCTURE SHALL BE MADE IN ACCORDANCE WITH MALL TENANT AND DESIGN CRITERIA. ALL ATTACHMENT METHODS TO STRUCTURE SHALL BE SUBMITTED TO LANDLORD FOR REVIEW I BEAM "C" CLAMP 3/8" 400 Lb. CAP. MIN. TOP CHORD OF JOIST. MASON TYPE SCBV SEISMIC BRACKET STRUCTURAL STEEL BEAM STRUCTURAL STEEL BEAM SEISMIC BRACKET ATTACHMENT TO A THREADED STEEL ROD SCALE: PROJECT NUMBER: DRAWING TITLE ISSUE / REVISION 51643 SOLARIS PLAZA 141 E MEADOW DRIVE #202 VAIL, CO 81657 SHEET NUMBER 10.26.16 PERMIT ISSUE 960 Atlantic Ave. Alameda, CA 94501 510 865 8663 mbharch.com 3371 Olcott Street Copyright c 2016 info@acies.net fx: (408) 522-5260 ph: (408) 522-5255 Santa Clara, CA 95054 ENGINEERING EXP: 10/31/17 12.15.16 PLAN CHECK COMMENTS ATTACHMENT TO STEEL BEAM SEISMIC ATTACHMENT TO STEEL BEAM NTS 5 NTS 4 NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED 12/19/16