HomeMy WebLinkAboutF16-0063 cut sheets.pdf Fire Sprinkler Material Submittal
Meridian Intermountain
PO Box 3940
Avon CO 81620 NICET _ - 'II
LE EIWITCH
F' T CHNOLOGY
For 0. 106788
Matterhorn Condo
1552 Matterhorn Dr
Vail CO 81657
Material
Ty FRB Sprinkler Head
Ty 3596 Sprinkler Head
TY LF II Sprinkler Head
Tyco Anvil Star Fittings and couplings
Merritt Weld Outlet
Tolco Nibco Hangers
PHD Swivel Hangers
Anvil Star valves
Nibco Valves
Tyco Sprinkler cabinet
Tyco CV-1 check Valve
Guardian FDC
FPPI signs
Wilkins 975 XL backflow
VicoWorldwide
Fire Protection Contacts www.tyco-fire.com
Products
Series TY-FRB, 5.6 K-factor
Upright, Pendent, and Recessed Pendent Sprinklers
Quick Response, Standard Coverage
General NOTICE
The TYCO Series TY FRB Sprinklers ._
Description described herein must be installed and
maintained in compliance with this doc- a
The TYCO Series TY-FRB,5.6 K-factor, ument, as well as with the applicable
Upright (TY313)and Pendent(TY323) standards of the National Fire Protec- moi- 1
Sprinklers described in this data sheet tion Association,in addition to the stan-
are
� 411 quick response,standard coverage, dards of any other authorities having !-
decorative 3 mm glass bulb-type spray jurisdiction. Failure to do so may impair
sprinklers designed for use in light or the performance of these devices.
ordinary hazard,commercial occupan- 4
cies such as banks, hotels, and shop- The owner is responsible for maintain- __,• {
ping malls. ing their fire protection system and -- -- -
devices in proper operating condition.
The recessed version of the Series TY- The installing contractor or sprinkler
FRB Pendent Sprinkler,where applica- manufacturer should be contacted with
ble, is intended for use in areas with a any questions.
finished ceiling.This recessed pendent
sprinkler uses one of the following:
• A two-piece Style 15 Recessed Sprinkler ---
Escutcheon with recessed adjust- Identification r
ment up to 5/8 inch (15,9 mm) from
the flush pendent position. `
--- !,
Number (SIN)
• A two-piece Style 20 Recessed -
—Escutcheon with recessed adjust- TY313 Upright 5.6K, 1/2"NPT
ment up to 1/2 inch (12,7 mm) from TY323 Pendent 5.6K, 1/2"NPT
the flush pendent position.
The adjustment provided by the Technical
Recessed Escutcheon reduces the Temperature Rating
accuracy to which the fixed pipe drops Data 135°F(57°C)
to the sprinklers must be cut. 155°F(68°C)
Intermediate level versions of Series Approvals 175 of(79 C)
200 F(93°C)
Y UL and C-UL Listed
TY-FRB Sprinklers are described in FM, LPC-,and VdSApproved
286°F(141°C)
Technical Data Sheet TFP357. Sprin- pP
kler guards and shields are described CE Certified Finishes
in Technical Data Sheet TFP780. Sprinklers with Polyester Finish are UL Sprinkler: Refer to Table A
and C-UL Listed as Corrosion-Resis- Recessed Escutcheon:White Coated,
tant Sprinklers. Chrome Plated, or Brass Plated
Maximum Working Pressure Physical Characteristics
175 psi (12.1 bar) Frame Bronze
250 psi(17.2 bar)* Button Brass/Copper
*The maximum working pressure of 250 psi Sealing Assembly Stainless
IMPORTANT (17.2 bar)only applies to the listing by Un- Steel w/TEFLON
Always refer to Technical Data derwriters Laboratories,Inc.(UL). Bulb Glass
Sheet TFP700 for the "INSTALLER Discharge Coefficient Compression Screw Bronze
WARNING"that provides cautions K=5.6 GPM/psi1i2(80,6 LPM/bar1i2) Deflector Bronze
with respect to handling and instal-
lation of sprinkler systems and com-
ponents. Improper handling and
installation can permanently dam- NICET : •. - i
age a sprinkler system or its compo- L : IWITCH
nents and cause the sprinkler to fail HNOLO
to operate in a fire situation or cause E T GY
it to operate prematurely. I. 106788
Page 1 of 4 FEBRUARY 2014 TFP172
NICET LEVEL ILLY----'
Vico LEWIS REIW ' H Worldwide
FPE TECH i LOGY Contacts www.tyco-fire.com
Fire Protection NO. i 6788
Products
RAPID RESPONSE Ser- : LFII Residential
4.9 K-factor Penden prinkler
Wet Pipe and Dry Pipe Systems
General Escutcheon reduces the accuracy to
which the pipe drops to the sprinklers
Description must be cut.
The Series LFII Residential Sprinklers _,
TYCO RAPID RESPONSE Series have been designed with heat sensi- ,.T, r.-
LFII
_LFII Residential 4.9K Pendent and tivity and water distribution charac-
Recessed Pendent Sprinklers(TY2234) teristics proven to help in the control
are decorative, fast response, frangi- of residential fires and to improve the
ble bulb sprinklers designed for use chance for occupants to escape or be
in residential occupancies such as evacuated.
homes, apartments, dormitories, and -
Dry Pipe System Application
hotels.When aesthetics and optimized The Series LFII Residential Pendent
flow characteristics are the major con- and Recessed Pendent Sprinklers
sideration, the Series LFII Residential offers a laboratory approved option NSF.
Sprinklers(TY2234)should be the first for designing dry pipe residential sprin
choice. kler systems,whereas,most residential —m
The Series LFII Residential Sprinklers sprinklers are laboratory approved for
are intended for use in the following wet systems only. Sprinkle,'
scenarios: Through extensive testing, it has been
• wet and dry pipe residential sprin- determined that the number of design Identification
kler systems for one- and two-fam- sprinklers (hydraulic design area) for
ily dwellings and mobile homes per the Series LFII Residential Pendent and Number (SIN)
NFPA 13D Recessed Pendent Sprinklers(TY2234)
• wet and dry pipe residential sprinkler need not be increased over the number TY2234
systems for residential occupancies of design sprinklers (hydraulic design
up to and including four stories in area)as specified for wet pipe sprinkler Technical
height per NFPA 13R systems,as is accustomed for density/
area sprinkler systems designed per Data
• wet and dry pipe sprinkler systems NFPA 13.
for the residential portions of any Consequently, the Series LFII Resi Approvals
occupancy per NFPA 13 dentia) Sprinklers offer the features UL Listed(for use with wet pipe and dry
The recessed version of the Series of non-water filled pipe in addition pipe systems)
LFII Residential Sprinklers is intended to not having to increase the number C-UL Listed(for use only with wet pipe
for use in areas with finished ceilings. of design sprinklers (hydraulic systems)
It employs a two-piece Style 20 design area) for systems designed to Certified to all requirements of
Recessed Escutcheon.The Recessed NFPA 13, 13D, or 13R. NSF/ANSI 61
Escutcheon provides 1/4 inch
(6,4 mm)of recessed adjustment or up NOTICE (Refer to the Design Criteria section for
to 1/2 inch(12,7 mm)of total adjustment details on these approvals.)
from the flush ceiling position. The The Series LFII Residential Pendent Maximum Working Pressure
adjustment provided by the Recessed and Recessed Pendent Sprinklers 175 psi(12,1 bar)
(TY2234) described herein must be
installed and maintained in compliance Discharge Coefficient
with this document and the applicable K=4.9 gpm/psi1i2(70,6 Ipm/bar1/2)
IMPORTANT standards of the National Fire Protec- Temperature Rating
Always refer to Technical Data tion Association (NFPA), in addition to 155°F(68°C)or 175°F(79°C)
Sheet TFP700 for the "INSTALLER the standards of any authorities having Finishes
with
WARNING"
that
provides
cautions jurisdiction.Failure to do so may impair Natural Brass,Pure White,Signal White,or
respecthandling the performance of these devices. Chrome Plated
lation of sprinkler systems and corn-
The owner is responsible for main-
ponents. Improper handling and tainin their fireresponsible
system
Physical Characteristics
installation can permanently damage g protectionFrame Brass
a sprinkler system or its components and devices in proper operating con- Button Copper
and cause the sprinkler to fail to dition. Contact the installing contrac- Sealing Assembly..Beryllium Nickel w/TEFLON
mm) ass
operate in a fire situation or cause it for or product manufacturer with any assBulb(
operatScrew Bronze
to operate prematurely. questions. Deflector Bronze
Page 1 of 6 JANUARY 2016 TFP400
VicoWorldwide
Fire Protection Contacts www.tyco-fire.com
Products
RAPID RESPONSE Series LFII Residential Sprinklers
4.4 K-factor Horizontal Sidewall
Wet Pipe Systems
General which the pipe nipples to the sprinklers
must be cut.
Description The Series LFII Residential Sprinklers
has been designed with heat sensitivity
The TYCO RAPID RESPONSE Series and water distribution characteristics
LFII Residential Horizontal Sidewall proven to help in the control of residen-
Sprinklers (TY2334) are decorative, tial fires and to improve the chance for ir
fast response,frangible bulb sprinklers occupants to escape or be evacuated.
designed for use in residential occu .4144,
-
pancies such as homes, apartments, NOTICE ..,
dormitories,and hotels.When aesthet The Series LFII Residential Horizontal
ics and optimized flow characteristics Sidewall Sprinklers(TY2334)described
are the major consideration,the Series herein must be installed and main
LFII Residential Sprinklers (TY2334) tained in compliance with this docu-
should be the first choice. ment and with the applicable standards
The Series LFII Residential Sprinklers of the National Fire Protection Associa-
are intended for use in the following tion,in addition to the standards of any
scenarios: authorities having jurisdiction. Failure
• wet pipe residential sprinkler sys- to do so may impair the performance
tems for one-and two-family dwell- of these devices.
ings and mobile homes per NFPA The owner is responsible for maintain-
13D ing their fire protection system and / .
• wet pipe residential sprinkler sys- devices in proper operating condition. / a
terns for residential occupancies up The installing contractor or sprinkler 4.' N•
to and including four stories in height manufacturer should be contacted with
per NFPA 13R any questions.
• wet pipe sprinkler systems for the Sprinkler �"
residential portions of any occu-
pancy
p
per NFPA 13 Identification
The recessed version of the Series
LFII Residential Sprinklers is intended Number (SIN)
for use in areas with finished walls. It
employs a two-piece Style 20 Recessed TY2334
Escutcheon. The Recessed Escutch- NSF®
eon provides 1/4 inch (6,4 mm) of Technical V
recessed adjustment or up to 1/2 inch —
(12,7 mm)of total adjustment from the Data „6
flush mounting surface position. The
adjustment provided by the Recessed Approvals Temperature Rating °
Escutcheon reduces the accuracy to UL and C-UL Listed 155°F(68°C)or 175 F(79 C)
Certified to all requirements of Finishes
NSF/ANSI 61 Natural Brass,Signal White,or Chrome
Plated
IMPORTANT (Refer to the Design Criteria section for Physical Characteristics
Always refer to Technical Data details on these approvals.) Frame Brass
Sheet TFP700 for the `INSTALLER Maximum Working Pressure Button Bronze
WARNING"that provides cautions Maximum 175 psi(12,1 bar) Sealing Assembly. Beryllium Nickel w/TEFLON
with respect to handling and instal- Bulb 3 mm Glass
lation of sprinkler systems and corn- Discharge Coefficient Compression Screw Bronze
ponents. Improper handling and K.4.4 GPM/psi1'2(63,4 LPM/barli2) Deflector Co..er
installation can permanently damage ��
a sprinkler system or its compo-
nents and cause the sprinkler to fail NIC I;EVEL III
to operate in a fire situation or cause L ' IS REIWITCH
it to operate prematurely. oLN: TECHNOLOGY
Page 1 of 6 JANUARY 2016 / NO. 10678$ TFP412