HomeMy WebLinkAboutF16-0063 cut sheets.pdf Fire Sprinkler Material Submittal Meridian Intermountain PO Box 3940 Avon CO 81620 NICET _ - 'II LE EIWITCH F' T CHNOLOGY For 0. 106788 Matterhorn Condo 1552 Matterhorn Dr Vail CO 81657 Material Ty FRB Sprinkler Head Ty 3596 Sprinkler Head TY LF II Sprinkler Head Tyco Anvil Star Fittings and couplings Merritt Weld Outlet Tolco Nibco Hangers PHD Swivel Hangers Anvil Star valves Nibco Valves Tyco Sprinkler cabinet Tyco CV-1 check Valve Guardian FDC FPPI signs Wilkins 975 XL backflow VicoWorldwide Fire Protection Contacts www.tyco-fire.com Products Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General NOTICE The TYCO Series TY FRB Sprinklers ._ Description described herein must be installed and maintained in compliance with this doc- a The TYCO Series TY-FRB,5.6 K-factor, ument, as well as with the applicable Upright (TY313)and Pendent(TY323) standards of the National Fire Protec- moi- 1 Sprinklers described in this data sheet tion Association,in addition to the stan- are � 411 quick response,standard coverage, dards of any other authorities having !- decorative 3 mm glass bulb-type spray jurisdiction. Failure to do so may impair sprinklers designed for use in light or the performance of these devices. ordinary hazard,commercial occupan- 4 cies such as banks, hotels, and shop- The owner is responsible for maintain- __,• { ping malls. ing their fire protection system and -- -- - devices in proper operating condition. The recessed version of the Series TY- The installing contractor or sprinkler FRB Pendent Sprinkler,where applica- manufacturer should be contacted with ble, is intended for use in areas with a any questions. finished ceiling.This recessed pendent sprinkler uses one of the following: • A two-piece Style 15 Recessed Sprinkler --- Escutcheon with recessed adjust- Identification r ment up to 5/8 inch (15,9 mm) from the flush pendent position. ` --- !, Number (SIN) • A two-piece Style 20 Recessed - —Escutcheon with recessed adjust- TY313 Upright 5.6K, 1/2"NPT ment up to 1/2 inch (12,7 mm) from TY323 Pendent 5.6K, 1/2"NPT the flush pendent position. The adjustment provided by the Technical Recessed Escutcheon reduces the Temperature Rating accuracy to which the fixed pipe drops Data 135°F(57°C) to the sprinklers must be cut. 155°F(68°C) Intermediate level versions of Series Approvals 175 of(79 C) 200 F(93°C) Y UL and C-UL Listed TY-FRB Sprinklers are described in FM, LPC-,and VdSApproved 286°F(141°C) Technical Data Sheet TFP357. Sprin- pP kler guards and shields are described CE Certified Finishes in Technical Data Sheet TFP780. Sprinklers with Polyester Finish are UL Sprinkler: Refer to Table A and C-UL Listed as Corrosion-Resis- Recessed Escutcheon:White Coated, tant Sprinklers. Chrome Plated, or Brass Plated Maximum Working Pressure Physical Characteristics 175 psi (12.1 bar) Frame Bronze 250 psi(17.2 bar)* Button Brass/Copper *The maximum working pressure of 250 psi Sealing Assembly Stainless IMPORTANT (17.2 bar)only applies to the listing by Un- Steel w/TEFLON Always refer to Technical Data derwriters Laboratories,Inc.(UL). Bulb Glass Sheet TFP700 for the "INSTALLER Discharge Coefficient Compression Screw Bronze WARNING"that provides cautions K=5.6 GPM/psi1i2(80,6 LPM/bar1i2) Deflector Bronze with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- NICET : •. - i age a sprinkler system or its compo- L : IWITCH nents and cause the sprinkler to fail HNOLO to operate in a fire situation or cause E T GY it to operate prematurely. I. 106788 Page 1 of 4 FEBRUARY 2014 TFP172 NICET LEVEL ILLY----' Vico LEWIS REIW ' H Worldwide FPE TECH i LOGY Contacts www.tyco-fire.com Fire Protection NO. i 6788 Products RAPID RESPONSE Ser- : LFII Residential 4.9 K-factor Penden prinkler Wet Pipe and Dry Pipe Systems General Escutcheon reduces the accuracy to which the pipe drops to the sprinklers Description must be cut. The Series LFII Residential Sprinklers _, TYCO RAPID RESPONSE Series have been designed with heat sensi- ,.T, r.- LFII _LFII Residential 4.9K Pendent and tivity and water distribution charac- Recessed Pendent Sprinklers(TY2234) teristics proven to help in the control are decorative, fast response, frangi- of residential fires and to improve the ble bulb sprinklers designed for use chance for occupants to escape or be in residential occupancies such as evacuated. homes, apartments, dormitories, and - Dry Pipe System Application hotels.When aesthetics and optimized The Series LFII Residential Pendent flow characteristics are the major con- and Recessed Pendent Sprinklers sideration, the Series LFII Residential offers a laboratory approved option NSF. Sprinklers(TY2234)should be the first for designing dry pipe residential sprin choice. kler systems,whereas,most residential —m The Series LFII Residential Sprinklers sprinklers are laboratory approved for are intended for use in the following wet systems only. Sprinkle,' scenarios: Through extensive testing, it has been • wet and dry pipe residential sprin- determined that the number of design Identification kler systems for one- and two-fam- sprinklers (hydraulic design area) for ily dwellings and mobile homes per the Series LFII Residential Pendent and Number (SIN) NFPA 13D Recessed Pendent Sprinklers(TY2234) • wet and dry pipe residential sprinkler need not be increased over the number TY2234 systems for residential occupancies of design sprinklers (hydraulic design up to and including four stories in area)as specified for wet pipe sprinkler Technical height per NFPA 13R systems,as is accustomed for density/ area sprinkler systems designed per Data • wet and dry pipe sprinkler systems NFPA 13. for the residential portions of any Consequently, the Series LFII Resi Approvals occupancy per NFPA 13 dentia) Sprinklers offer the features UL Listed(for use with wet pipe and dry The recessed version of the Series of non-water filled pipe in addition pipe systems) LFII Residential Sprinklers is intended to not having to increase the number C-UL Listed(for use only with wet pipe for use in areas with finished ceilings. of design sprinklers (hydraulic systems) It employs a two-piece Style 20 design area) for systems designed to Certified to all requirements of Recessed Escutcheon.The Recessed NFPA 13, 13D, or 13R. NSF/ANSI 61 Escutcheon provides 1/4 inch (6,4 mm)of recessed adjustment or up NOTICE (Refer to the Design Criteria section for to 1/2 inch(12,7 mm)of total adjustment details on these approvals.) from the flush ceiling position. The The Series LFII Residential Pendent Maximum Working Pressure adjustment provided by the Recessed and Recessed Pendent Sprinklers 175 psi(12,1 bar) (TY2234) described herein must be installed and maintained in compliance Discharge Coefficient with this document and the applicable K=4.9 gpm/psi1i2(70,6 Ipm/bar1/2) IMPORTANT standards of the National Fire Protec- Temperature Rating Always refer to Technical Data tion Association (NFPA), in addition to 155°F(68°C)or 175°F(79°C) Sheet TFP700 for the "INSTALLER the standards of any authorities having Finishes with WARNING" that provides cautions jurisdiction.Failure to do so may impair Natural Brass,Pure White,Signal White,or respecthandling the performance of these devices. Chrome Plated lation of sprinkler systems and corn- The owner is responsible for main- ponents. Improper handling and tainin their fireresponsible system Physical Characteristics installation can permanently damage g protectionFrame Brass a sprinkler system or its components and devices in proper operating con- Button Copper and cause the sprinkler to fail to dition. Contact the installing contrac- Sealing Assembly..Beryllium Nickel w/TEFLON mm) ass operate in a fire situation or cause it for or product manufacturer with any assBulb( operatScrew Bronze to operate prematurely. questions. Deflector Bronze Page 1 of 6 JANUARY 2016 TFP400 VicoWorldwide Fire Protection Contacts www.tyco-fire.com Products RAPID RESPONSE Series LFII Residential Sprinklers 4.4 K-factor Horizontal Sidewall Wet Pipe Systems General which the pipe nipples to the sprinklers must be cut. Description The Series LFII Residential Sprinklers has been designed with heat sensitivity The TYCO RAPID RESPONSE Series and water distribution characteristics LFII Residential Horizontal Sidewall proven to help in the control of residen- Sprinklers (TY2334) are decorative, tial fires and to improve the chance for ir fast response,frangible bulb sprinklers occupants to escape or be evacuated. designed for use in residential occu .4144, - pancies such as homes, apartments, NOTICE .., dormitories,and hotels.When aesthet The Series LFII Residential Horizontal ics and optimized flow characteristics Sidewall Sprinklers(TY2334)described are the major consideration,the Series herein must be installed and main LFII Residential Sprinklers (TY2334) tained in compliance with this docu- should be the first choice. ment and with the applicable standards The Series LFII Residential Sprinklers of the National Fire Protection Associa- are intended for use in the following tion,in addition to the standards of any scenarios: authorities having jurisdiction. Failure • wet pipe residential sprinkler sys- to do so may impair the performance tems for one-and two-family dwell- of these devices. ings and mobile homes per NFPA The owner is responsible for maintain- 13D ing their fire protection system and / . • wet pipe residential sprinkler sys- devices in proper operating condition. / a terns for residential occupancies up The installing contractor or sprinkler 4.' N• to and including four stories in height manufacturer should be contacted with per NFPA 13R any questions. • wet pipe sprinkler systems for the Sprinkler �" residential portions of any occu- pancy p per NFPA 13 Identification The recessed version of the Series LFII Residential Sprinklers is intended Number (SIN) for use in areas with finished walls. It employs a two-piece Style 20 Recessed TY2334 Escutcheon. The Recessed Escutch- NSF® eon provides 1/4 inch (6,4 mm) of Technical V recessed adjustment or up to 1/2 inch — (12,7 mm)of total adjustment from the Data „6 flush mounting surface position. The adjustment provided by the Recessed Approvals Temperature Rating ° Escutcheon reduces the accuracy to UL and C-UL Listed 155°F(68°C)or 175 F(79 C) Certified to all requirements of Finishes NSF/ANSI 61 Natural Brass,Signal White,or Chrome Plated IMPORTANT (Refer to the Design Criteria section for Physical Characteristics Always refer to Technical Data details on these approvals.) Frame Brass Sheet TFP700 for the `INSTALLER Maximum Working Pressure Button Bronze WARNING"that provides cautions Maximum 175 psi(12,1 bar) Sealing Assembly. Beryllium Nickel w/TEFLON with respect to handling and instal- Bulb 3 mm Glass lation of sprinkler systems and corn- Discharge Coefficient Compression Screw Bronze ponents. Improper handling and K.4.4 GPM/psi1'2(63,4 LPM/barli2) Deflector Co..er installation can permanently damage �� a sprinkler system or its compo- nents and cause the sprinkler to fail NIC I;EVEL III to operate in a fire situation or cause L ' IS REIWITCH it to operate prematurely. oLN: TECHNOLOGY Page 1 of 6 JANUARY 2016 / NO. 10678$ TFP412 i/L_