HomeMy WebLinkAboutF16-0058_Equipment Data.pdf 0 OF go._/ 12 ill 111 IS if Vail Fire 8 Emergency Services 09/29/16 western States Fire Protection Co. Pøee&4t 41ue4 4,,,,,e preizertv 7026 South Tucson Way Centennial, CO 80112 (303) 792-0022 Fax (303) 792-9049 Fire Protection Equipment Submittal Vail Cascade Remodel 1300 Westhaven Drive Vail, CO 81657 WSFP #CS2893 Prepared by: Bryan Horn,PE Senior Project Manager Western States Fire Protection Co. 7026 South Tucson Way Centennial. CO 80112 (608)215-0568 Email:bryan.horn@wsfp.us September 1,2016 olti OF 10 r e, Reliable ® Model F1 FR Seri Quick Response '30 si' ; Glass Bulb Sprink - 1(1°''° Vail Fire&Emergency Services 09/29/16 G Model F1 FR56 Sprinkler Types - , Standard Spray Upright Standard Spray Pendent0 ill Conventional Upright/Pendent Vertical Sidewall :- --, -rn Horizontal Sidewall — Model Fl FR56 Recessed Sprinkler Types Upright Pendent Conventional Standard Spray Pendent Horizontal Sidewall ,; Model Fl FR56 Concealed Sprinkler Types1r 4 -' Standard Spray Pendent . �. ; :;; Model F1FR42, F1FRXLH & F1FR28 Sprinkler r� Types Vertical Sidewall Horizontal Sidewall Recessed Standard Spray Upright Pendent/F1/F2 Standard Spray Pendent — Model F1 FR40 Sprinkler Types Standard Spray Pendent ' ., ,� . .., • '. , i Model F1 FR42, F1 FR40, F1 FRXLH & F1 FR28 _ Recessed Sprinkler Types .. '. : 1 .• . Standard Spray Pendent �` :,t .. Model F1 FR56LL & F1 FR42LL NSF Certified Low Recessed Concealed Recessed Lead Sprinkler Types Horizontal Sidewall Pendent Pendent/FP Standard Spray Pendent with less than 0.25% Lead 41.1116 - Content Listing & Approvals ! .__=_. The following organizations provide Listings or Approvals •.Yaw for various Model Fl FR series sprinklers. See the Design CM and Installation table in this Bulletin for information on XLH Upright XLH Pendent XLH Recessed specific listings and approvals applicable to each sprin- Pendent F1/F2 kler. 1. Underwriters Laboratories Inc. and Certified for Product Description Canada(cULus). Reliable Model F1FR series sprinklers 2. FM Approvals (FM) are quick-response automatic sprin- klers with a glass bulb thermal element. • 3. Loss Prevention Certification Board (LPCB) A 4. VdS Schadenverhutung GmbH (VdS) Model F1FR series sprinklers are Stan 5. NSF Certified to NSF/ANSi Standard 61 Annex G dard Spray sprinklers, with the excep- (NSF) tion of the Model F1 FR56 Conventional XLH Recessed 6. EC Certificate: 0786-CPD-40239 (RA1414), 0786- sprinkler which is an Old-style/Conven- Pendent FP CPD-40251 (RA1425), 0786-CPD-40252 (RA1475) tional sprinkler. (EC) The Model F1FR Series automatic sprinklers utilize a 3.0 mm frangible glass bulb.These sprinklers have demonstrat- UL Listing Category ed response times in laboratory tests which are five to ten Sprinklers,Automatic&Open(VNIV) times faster than standard response sprinklers. This quick Quick Response Sprinkler response enables the Model Fl FR Series sprinklers to apply water to a fire faster than standard-response sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely man- ufactured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 olti OF lo4,! At normal temperatures, the glass bulb contains the fluid Model F1FR Series sprinklers must be in' in both the liquid and vapor phases. The vapor phase can Reliable sprinkler installation wrench identifi be seen as a small bubble. As heat is applied, the liquid and Installation Information table in this B expands, forcing the bubble smaller and smaller as the liq- wrench may damage the sprinkler. A leak ti• uid pressure increases. Continued heating forces the liquid can be obtained with a torque of 8 to 18 lb-ft to push out against the bulb, causing the glass to shatter, Do not tighten sprinklers over the maximum re. ' 1g0] opening the waterway and allowing the deflector to distrib- installation torque. Exceeding the maximum reco ute the discharging water. installation torque may cause leakage orim� . ii An '8rricy Services Model Fl FR Series sprinklers provide a wide range of op- sprinkler. tions where quick-response, glass bulb sprinklers are used: Recessed Sprinklers • Pendent, recessed pendent, upright, horizontal side- Model F1 FR Series Recessed sprinklers are to be installed wall, and vertical sidewall deflectors as shown in Fig. 1, Fig. 2,or Fig.3, as applicable to the spe- • K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 cific model being installed.The Recessed Escutcheon Data metric), and 5.6 (80 metric) table in the Bulletin identifies the only recessed escutcheons • Flush, recessed, and concealed installations that are permitted to be used with each Model Fl FR Series See the Design and Installation Information table in this Recessed sprinkler.The use of any other recessed escutch- Bulletin for information on the approvals and availability of eon will void all approvals and negate all warranties. specific Model Fl FR series sprinkler configurations. Concealed Sprinklers Model F1FR Recessed Pendent and Recessed Horizon- Model Fl FR Series Concealed Pendent sprinklers are to tal Sidewall sprinklers are required to be used with Reliable be installed as shown in Fig.4 or Fig. 5, as applicable to the Model F1, F2, or FP recessed escutcheons. See the Re- selected cover plate. Model F1 FR56 Concealed Pendent cessed Escutcheon Data table in this Bulletin for listing and and Model F1 FR56LL Concealed Pendent sprinklers have approval information with each specific Model F1FR series a factory-installed Model CCP cup. A protective cap is in- sprinkler. Model Fl and F2 recessed escutcheons, shown in stalled at the factory that should remain on the sprinkler until Fig. 1 and 3, are a friction fit assembly allowing for 3/4-inch the sprinkler is installed and should then be reinstalled on (19mm) and 1/2-inch (12.7mm) of adjustment, respectively. the sprinkler until the cover plate is installed.The concealed Model FP recessed escutcheons, shown in Fig. 2, provide a sprinkler assemblies are completed by the installation of a 1/2-inch (12.7mm)threaded adjustment. Model CCP push-on/thread-off cover plate assembly. The Model F1 FR56 Concealed Pendent and Model F1 FR56LL cover plate and sprinkler cup assemblies are joined using Concealed Pendent sprinklers are required to be used with a cover plate skirt with flexible tabs for threaded engage- Model CCP cover plates.A standard profile Model CCP cov- ment. A choice of two Model CCP cover plate assemblies er plate is available that provides up to 1/2-inch(12.7mm)of provides either 1/2-inch (13mm) or 5/8-inch (8mm)of cover cover plate adjustment. In addition,a low profile Model CCP adjustment. Do not install Model F1FR Series Concealed cover plate is also available that provides up to 5/16-inch Pendent sprinklers in ceilings which have positive pressure (8.0mm)of cover plate adjustment. See the Design and In- in the space above. stallation Information and Listed and Approved Temperature Model F1FR Series Concealed Pendent sprinklers require a Ratings tables in this Bulletin for further information on ap- 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The proved cover plate options. Model RC1 wrench is used to engage the sprinkler wrenching Application surfaces and to install the sprinkler in the fitting. Remove the Model Fl FR Series sprinklers are intended for use in protective cap to install the sprinkler,then reinstall the protective accordance with NFPA 13, FM Property Loss Prevention cap until the cover plate is installed. When inserting or remov- Data Sheets, and the requirements of the Authority Hav- ing the wrench from the sprinkler/cup assembly,care should be ing Jurisdiction. Care must be exercised that the k-factor, taken to prevent damage to the sprinkler. Do not wrench any temperature rating, deflector style, and sprinkler type are other part of the sprinkler/cup assembly. Installation is corn- in accordance with the requirements of the applicable pleted by removing the protective cap from the sprinkler and design and installation standards. In addition, Model pushing the cover plate onto the cup. Final adjustment is made F1 FR Series sprinklers must be used in accordance with by hand turning the cover plate until the skirt flange makes full their listings and approvals, as well as the information contact with the ceiling.Cover plate removal requires turning the provided in this Bulletin. cover plate in the counter clockwise direction.After installation, Installation inspect all sprinklers to ensure that there is a gap between the Glass bulb sprinklers have orange bulb protectors or pro- cover plate and ceiling and that the four cup slots are open and tective caps to minimize bulb damage during shipping,han- free from any air flow impediment to the space above. dling and installation. Reliable sprinkler installation wrench- Concealed cover plate/cup assemblies are listed only for es are designed to install sprinklers with bulb protectors in use with specific sprinklers.The use of any concealed cover place.Remove the bulb protector at the time when the sprin plate/cup assembly other than the Reliable Model CCP with kler system is placed in service for fire protection. Removal Model F1 FR56 Concealed Pendent and Model F1 FR56LL of the bulb protector before this time may leave the bulb vul- Concealed Pendent sprinklers or the use of the Model CCP nerable to damage. Remove bulb protectors by undoing the Concealed cover plate assembly on any sprinkler with which clasp by hand. Do not use tools to remove bulb protectors. it is not specifically listed my prevent good fire protection and will void all guarantees,warranties, listings and approvals. 2. Technical Data: z � 4. Sensitivity: Quick-response # Thread Size: 1/2-inch NPT standard; ISO 7-R1/2 optional , Maximum Working Pressure: 175 psi (12 bar) - 100% Factory tested hydrostatically to 500 psi (3. 7.0 b SIN RA1425, RA1414& RA1435 cULus listed for 250 psi (17 bar) ig07 Vail Fire&Emergency Services Design and Installation Information 09/29/16 Nominal Nominal Nominal Listings Orifice Deflector/ Sprinkler Installation Approval Model K factor Diameter Orientation Height Wrench SIN and Notes US Metric inches mm inches mm Approvals Pendent 2.25 57 D RA1411 cULus 2 F1FR28 2.8 40 3/8 10 Recessed Pendent 2.25 57 GFR2 RA1411 cULus 2 Upright 2.25 57 D RA1421 cULus 1,2 Pendent 2.25 57 D RA1418 VdS F1 FR40 4.0 57 3/8 10 Recessed Pendent 2.25 57 GFR2 RA1418 VdS Pendent 2.25 57 D RA1413 cULus 2 F1FR42 4.2 60 7/16 10 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 Upright 2.25 57 D RA1423 cULus 1,2 Pendent 2.25 57 D RA1410 cULus, NSF F1FR42LL 4.2 60 7/16 10 Recessed Pendent 2.25 57 GFR2 RA1410 cULus, NSF F1FRXLH Pendent 2.25 57 D RA1413 cULus 2 (F1FR42 4.2 60 7/16 10 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 with Pintle) Upright 2.25 57 D RA1423 cULus 1,2 Pendent 2.25 57 D RA1414 cULus, FM, 1,2,3,4 LPCB,VdS, EC Recessed Pendent 2.25 57 GFR2 RA1414 cULus, FM, 1,2,3,4 LPCB,VdS, EC F1FR56 5.6 80 1/2 15 Concealed Pendent 2.25 57 RC1 RA1414 cULus,VdS,EC 5,6 Upright 2.25 57 D RA1425 cULus, FM, 1,2,3,4 LPCB,VdS, EC "Conventional 2.25 57 D RA1475 LPCB,VdS, EC 4 (Pendent or Upright)" Pendent 2.25 57 D RA1415 cULus, NSF 1 F1FR56LL 5.6 80 1/2 15 Recessed Pendent 2.25 57 GFR2 RA1415 cULus, NSF Concealed Pendent 2.25 57 RC1 RA1414 cULus, NSF 6 Horizontal Sidewall 2.63 67 D RA1435 cULus, FM 1,2,3,7 F1FR56 5.6 80 1/2 15 Recessed Horizontal 2.63 67 GFR2 RA1435 cULus, FM 8 Sidewall F1FR56 5.6 80 1/2 15 Vertical Sidewall 2 25 57 D RA1485 cULus, FM, 1,2,3,9 (Pendent or Upright) LPCB (I)cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. (2)cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. (3)Available with FM approved Polyester coating in black or white. (4)Available with LPCB and VdS approved Polyester coating. (5)VdS and EC approvals of the F1FR56 Concealed Pendent sprinkler are for 155°F(68°C)temperature rated sprinklers only.VdS approved sprin- klers must use Norbulb brand glass bulbs with the 1/2-inch(12.7mm)adjustment Model CCP cover plate only. (6) Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates, available as either standard depth with 1/2-inch(12.7mm)of adjustment or low profile with 5/16-inch(8.0 mm)of adjustment. (7)cULus Listing of the F1FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. FM Approval of the F1FR56 Hori- zontal Sidewall sprinkler is for Light Hazard occupancies only. (8)cULus Listing and FM Approval of the Fl FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (9)The F1FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies. Minimum to maximum deflector to ceil- ing distance shall be 4 inches to 12 inches(102mm to 305mm). LPCB approval of the Fl FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. 3. rF I/4% Listed and Approved Temperature Ratings z � 4. Ordinary Temp. Intermediate Temp. Hig I # J• Classification Classification Class , Deflector/ 100°F(38°C)Max.Ambient _ 150°F(65°C) Max. Ambient 225°F(1 r `a IS Model i. Orientation Tedip. Temp. Ambient407 135°F(57°C) 155°F(68°C) 175°F(79°C) 200°F(93°C) 286°F(141°C) Temp. Rating Temp. Rating Temp. Rating Temp. Rating Ra�ire&Emergency Services Orange Bulb Red Bulb Yellow Bulb Green Bulb Blue BulI6 Pendent cULus F1FR28 Recessed Pendent cULus -- Upright cULus F1 FR40 Pendent VdS Recessed Pendent VdS -- Pendent cULus F1FR42 Recessed Pendent cULus -- Upright cULus F1FR42LL Pendent -- cULus, NSF -- Recessed Pendent -- cULus, NSF -- Pendent cULus F1FRXLH Recessed Pendent cULus -- Upright cULus Pendent cULus, FM, LPCB,VdS, EC Recessed Pendent cULus, FM, LPCB,VdS, EC -- F1FR56 Concealed Pendent* cULus cULus,VdS,EC cULus -- Upright cULus, FM, LPCB,VdS, EC "Conventional LPCB,VdS, EC (Pendent or Upright)" Pendent -- cULus, NSF -- F1FR56LL Recessed Pendent -- cULus, NSF -- Concealed Pendent" -- cULus, NSF -- Horizontal Sidewall cULus, FM F1FR56 Recessed Horizontal Sidewall cULus, FM -- F1FR56 Vertical Sidewall(Pen cULus, FM, LPCB dent or Upright) * Model F1FR56 Concealed Pendent and F1 FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover plate. For Intermediate Temperature Classification sprinklers use a 165°F(74°C)temperature rated cover plate. Recessed Escutcheon Data Listed and Approved Recessed Escutcheons Deflector/ Model F1 Model F2 Model FP Model Orientation (Fig. 1 &3) (Fig. 1 &3) (Fig.2) SIN 3/4-inch(19mm) 1/2-inch(12.7mm) 1/2-inch(12.7mm) adjustment adjustment adjustment F1FR28 Recessed Pendent cULus cULus cULus RA1411 F1FR40 Recessed Pendent VdS VdS VdS RA1418 F1FR42 Recessed Pendent cULus cULus cULus RA1413 F1FR42LL Recessed Pendent cULus, NSF cULus, NSF cULus, NSF RA1410 F1 FR42XLH Raraccarl Panrlant rl II i is rl II i is rl II i is RA 1 d1' F1FR56 Recessed Pendent cULus, LPCB,VdS, cULus, FM, LPCB, cULus,VdS, EC RA1414 EC VdS, EC F1 FR56LL Recessed Pendent cULus, NSF cULus, NSF cULus, NSF RA1415 F1FR56 Recessed Horizontal Sidewall cULus cULus, FM cULus RA1435 4. olti OF 10 ilk.1 11 2 1/4'"HOLE D/A. J # P7 [57.2mm] 1 15/16"DIA [49.2mm] Oj "LS [__— — -=-I Vail Fire&Emergency Se ices rs olti OF 10 ."4„,e FACE OF FITTING S TO FACE OF CEILING DIMENSION #%-ill ,T Fl ESCUTCHEON /<��������A + A' MAXIMUM RECESS = 1"[25.4mm] ' AT INIMUM RECESS = 3/879.5mmJ / F1 ESCUTCHEON O.? F2 ESCUTCHEON 1` AT MAXIMUM RECESS = 1-3/8'[34.9mm] g0] AT MAXI UM RECESS = 3/4"[19mmJ AT MINIMUM RECESS = 2-1/16'[52.4mm] Va ire&Emergen y Services AT MINIM , RECESS = 3/8"[9.5mm] Z F2 ESCUTCHEON 0• 9/16 AT MAXIMUM RECESS = 1-5/87-41.3mm] — 1/4" HOLE DIA. 1/8„ AT MINIMUM RECESS = 2-1/16'[52.4m 57.2mm] [3.2mm] 1" X 1 " REDUCER 1 r-,— _r_ PI _ I nl{I, r, (1) I i I 4"-12" 1 15/16" DIA.' 1 -iim _ IIII 1 III / xi - _---- [101.6mm-304.8mm] [49.2mm] 11111 I'llllllll II 2 27/32" DIA. CEILING TO I 041 [72.2mm] DEFLECTOR JL_J All. 1.,,'y ' I TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS. Fl ESCUTCHEON 3/4"[19mm] ADJUS ENT F2 ESCUTCHEON 1/2[12.7mm] DJUSTMENT 013FGOJE RECESSED HSW W/F1 OR ' ES'UTCHEON (1) FM APPROVED FOR 4" — 6" [101.6MM — 15• MM] CEILING TO DEFLECTOR WITH F2 ONLY. F..3 Model Fl FR56 Recessed Horizontal Si.-wall spri' ler with Model Fl or F2 escutcheon 1" x 7/2" REDUCING TEE OR ELBOW TR - - - - - -+- - - - i{-F - - - _ I IT 111 1 n j r- - 2 5/8" PIA. 2 516" DIA — ' �� l' HOLE IN CE.NG L J CUP r i l 'I ��. I�� 01:vu lilts ' 1 1 " MAX. �� iii ) FACE 0 FITTING //////, FACE 0 CEILING ,`__1! if 1 �� I r������/J7-0 DIMENSIb CEIL ' G _ Iii i, i ������ i ----- /2" MAX. T - - 15/16" COV'R ADJUSTMENT NN/1 COVER PLATE ASSEMBLY3 5/16" DIA. SPRINKLER / CONCEALED, 1/2" ADJUSTMENT 017FGO1A Fig.4 Model F1 FR56/F1 FR56LL Concealed Pendent sprinkler with standard depth 1/2-inch(12.7mm)adjustment-Model CCP cover plate 6. olti OF 10 .r.4-14o 1" x 7/2" REDUCING Z 4. TEE OR ELBOW ., 70 Oj 556P" r 2 5/8" P A. Vail Fire&Emergency Se ices 2 5/16" I ' - HOLE * CEILING 09/29/16 CUP i . T, I ,.....do ®3'aEI lilt 1 1/2 MAX. tulii;.. • s.. FACE OF FITTING """"A (' hn 0 TO FACE OF CEILING ,l ,`II��4. r://////= DIMENSION '�\ CEILING ' -� 5/16" MAX. �tim' 3/4" COVER ADJUSTv" T CO PLATE t ASSEMBLY 3 5/16" DIA. SPRINKLER CONCEALED, 5/1 6" ADJUSTMENT 017FG02A /- Fig.5-Model Fl FR56/F1 FR56LL Concealed Pendent sprinkler with low profile 5/16-inch(8.0mm)adjustment-Model CCP cover plate Maintenance Material Data The Model Fl FR Series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA Frame: DZR Brass, QM Brass,or Low Lead Brass 25. Do not clean sprinklers with soap and water,ammonia or Deflector: CDA Alloy 220, 260, or 510 any other cleaning fluids. Remove dust by using a soft brush Load Screw\Pintle: CDA Alloy 360 or 544 or gentle vacuuming. Replace any sprinkler which has been painted(other than factory applied)or damaged in any way. Cup: CDA Alloy 651 or 693 A stock of spare sprinklers should be maintained to allow Washer: Nickel Alloy 440 or 360, coated with PTFE quick replacement of damaged or operated sprinklers. Adhesive Tape Finishes (1) Bulb: Glass Standard Finishes Sprinkler Escutcheon Cover plate(') Bronze Brass Chrome Ordering Information Chrome Plated Chrome White Specify: Polyester Plated 1. Sprinkler Model: [F1 FR28][F1 FR40][F1 FR42] Coated(4)(5)(6) White Painted [F1 FR42LL][F1 FRXLH][F1 FR56][F1 FR56LL] Speciai Application 1-inishes 2. Sprinkler Deflector/Orientation: [Pendent][Recessed Sprinkler Escutcheon Cover plate(') Pendent][Upright][Conventional][Horizontal Sidewall] Electroless Nickel Electroless Nickel Bright Brass [Recessed Horizontal Sidewall][Vertical Sidewall]3 PTFE g 3. Sprinkler threads: [1/2-inch NPT][ISO 7-R1/2] Bright Brass Bright Brass Black Plating 4. Sprinkler Temperature Rating: [135°F (57°C)][155°F Black Plated Black Plated Black Paint Black Paint(2)(6) Black Paint Off White (68°C)][175°F(79°C)][200°F(93°C)][286°F(141°C)] Off White(2)(6) Off White Satin Chrome 5. Sprinkler Finish Chrome Dull Chrome Dull 6. Escutcheon Model: [F1][F2][FP] (1)Other finishes and colors are available on special order. Consult the 7. Escutcheon Finish (where applicable) factory for details.Custom color painted sprinklers may not retain their 8. Cover plate Model: [standard profile CCP 1/2-inch UL Corrosion resistance listing.Coverplate custom paint is semi-gloss, (12.7mm) adjustment][low profile CCP 5/16-inch unless specified otherwise. (2) cULus Listed only. (8.0mm) adjustment] (3) 200°F(93°C)maximum. 9. Cover plate Temperature Rating: [135°F(57°C)for use (4) cULus listed "corrosion resistance" applies to SIN Numbers RA1435 with Ordinary Temperature sprinklers][165°F (74°C) (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and for use with Intermediate Temperature sprinklers] RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. 10. Cover plate Finish (5) FM Approvals finish as"Polyester coated"applies to SIN Number RA1414,RA1435 and RA1425 in standard black or white. Note: When Model Fl FR Series Recessed sprinklers are ordered, the (6)LPCB and VdS Approved finish applies only to RA1425, RA1414, RA1418 sprinklers and escutcheons are packaged separately. (VdS)and RA1475. (7)cULus listed Corrosion Resistant 7. oto OF iv,! Model Fl FR QR Reliable ..c . ..,7 ® K8.0 (115 metric) Quick ResponseQ '6# 15/t Coverage Sprinkl &EmergencyServrgs 2 16 A complete line of UL Listed and FM Approved quick response extended coverage sprinklers for light hazard applications. —x ,, ::.,> 4 h,Syx- Horizontal Sidewall Sprinklers are approved 1 . -k` I (1 ' .for installation 4" 12" (102mm 305mm) ,., e below the ceiling. Model Fl FR QREC Sprinkler Types ' Extended Coverage Pendent Extended Coverage Horizontal Sidewall Extended Coverage Recessed Extended • EC-9 Deflector Pendent Coverage Pendent Model Fl FR QREC Recessed Sprinkler Types Recessed Extended Coverage Pendent Recessed Extended Coverage Horizontal ' e,� — ' "' Aw . Sidewall: 111611. 11111pr VI W• EC-9 Deflector /f , For Model Fl FR QREC 1/2" K 5.6 (80) Sprinkler Types refer to Bulletin 028. Extended Coverage Recessed Extended Horizontal Sidewall EC-9 Coverage Horizontal Sidewall Approval Organizations EC-9 1. Underwriters' Laboratories, Inc. (UL) 2. Underwriters Laboratories of Canada (ULC) 3. Factory Mutual Approvals (FM) 4. NYC MEA 258-93-E UL Listing Category The glass bulb consists of an accurately controlled amount Sprinklers, Automatic & Open of special fluid hermetically sealed inside a precisely manu- Quick Response Extended Coverage Sprinkler factured glass capsule. This glass bulb is specially con structed to provide fast thermal response. The balance of UL Guide Number parts are made of brass, copper and beryllium nickel. VN IV The temperature rating of the sprinkler is identified by the Note: Consult appropriate FM Installation Standards color of the glass bulb. regarding limitations of room size, ceiling height and Application minimum wall fire resistance rating. Product Description Quick response sprinklers are used in fixed fire protec- tion systems: Wet, Dry, Deluge or Preaction. Care must be Reliable Models F1FR QREC and F1FR QREC Recessed exercised that the orifice size, temperature rating, deflector Sprinklers are quick response sprinklers which combine the style and sprinkler type are in accordance with the latest durability for a standard sprinkler with the attractive low pro- published standards of the National Fire Protection Asso- file of a decorative sprinkler. ciation or the approving authority having jurisdiction. Quick The Models Fl FR QREC and Fl FR QREC Recessed Auto- response sprinklers are intended for installation as specified matic Sprinklers utilize a 3.0mm frangible glass bulb. These in NFPA 13. sprinklers have demonstrated response times in laboratory tests which are five times faster than standard response sprinklers. This quick response enables these sprinklers to apply water to a fire faster than standard response sprinklers of the same temperature rating. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 40 OF gr. ,del F1FR QREC Pendent Sprinkler c De -ctor: EC Insta .tion Wrench: Model D Sprinkler Wrencheb Appro -I Type: Quick Response Extended Coverage-Light Hazard Occupancy o #x Mk,IIMAIQf Installation B ata: a ��i{ -rgency Services I pprA ii i Nominal Nominal Thread Sprinkler Temperature Approval Sprinkler K-Factor p pIdentification Orifice Size S Metric Length Rating Organizations Number(SIN) 17/32" 3/4" NPT 8.0 115 2.2" 135°F(57°C) 1,2,3,4 R4842 �, (20mm) (R3/4) (56.1mm) 155°F(68°C) ,. Model F1FR QREC Recesses Pendent Sprinkler Deflector: EC Installation Wrench: Model GFR2 irinkler Wrench Approval Type: Quick Response Extended Coverage-Light Hazard Occupancy Installation Data: NominalSprinkler Nominal Thread K-Factor Sprinkler Temp;rature Approv. 1) Orifice Size Length Rati • Organiz. ions Identification US Metric Number(SIN) 17/32" 3/4"NPT 8 0 115 2.2" 135°F(57°C 2, 3,4 R4842 (20mm) (R3/4) (56.1 mm) 155°F(68°C) (1)Refer to escutcheon data table for dimensions. Model Fl FR QREC Pendent and Recessed 'endent Required Minimum Flow/Pressure Maximu Flow Rate Pressure Coverage ,rea2 1/4"HOLE DIA. gpm(L/min) psi (bar) Width x ength [5Z 15mm] 1 15/16"DIA ft.x ft. m x m) [49.21mm] 26 (98.4) 10.6(0,7) 16 x . (4.9 x 4.9) - 33 (125.0) 17.0(1,2) 18/ 18 (5.5 x 5.5) 1"x 3/4"REDUCER TURN COLLAR - - OR UNTIL TIGHT I"X 1/2"REDUCER 40 (151.4) 25.0(1,7) ! x 20 (6.0 x 6.0)(2) AGAINST SPRINKLER WRENCH BOSS _\ _ (2)UL/ULC Listed for both Pendent and Recessed Pendent at FACE OF FITTING TO 135°F(57°C)only. II Emma II CEILING DIMENSION(2) �s ADJUSTMENT 0 00'V?J p�, A_ f[[3.18mm] 1}I 1- i 2 27/32 DIA. [72.23mm] 136FG028 2. Model F1FR QREC Horizontal Sidewall Sprinkler z � 4. Deflector: EC-9 # Installation Wrench: Model D Sprinkler Wrench Approval Type: Quick Response Extended Coverage-Light Hazard Occupancysg�7 o I Installation DataVail Fire&Emergency Services I - 09/29/16 Nominal Sprinkler Nominal Thread K-Factor Sprinkler Approval(2) Temperature p e Orifice Size Length Organizations Rating Identification /; US Metric Number(SIN) 135°F (57°C) "/32" 3/4" NPT 8.0 115 2'85 1,2,3,4 155°F (68°C) R4862 li (20mm) (R3A) (72.4mm) 175°F (78°C) Model F1FR QREC Recessed Horizontal Sidewall Sprinkler Deflector: EC-9 Installation Wrench: Model GFR2 Sprinkler Wrench Approval Type: Quick Response Extended Coverage-Light Hazard Occupancy Model Fl FR QREC Horizontal Sidewall and Recessed Horizontal Sidewall Required Minimum Flow/Pressure Flow Rate Pressure Maximum Approvalt2) Deflector to Ceiling gpm(Umin) psi(bar) Coverage Area Temperature Organizations Dimension UL FM UL FM Width x Length Rating(') Fl F2 Min.-Max. ft.x ft.(m x m) Inches(mm) 26 (98.4) - 10.6 (0,7) - 16 x 16 (4.9 x 4.9) 135°F (57°C) 6-12 (153-305) 29 (109.8) 32 (121.1) 13.1 (0,9) 16.0 (1,1) 16x16 (4.9x4.9) 4-12 (102-305) 29 (109.8) 36 (136.3) 13.1 (0,9) 20.2 (1,4) 16 x 18 (4.9 x 5.5) 155°F (68°C) 1,2,4 1,2,3,4 4-12 (102-305) 32 (121.1) 40 (151.4) 16.0 (1,1) 25.0 (1,7) 16x20 (4.9x6.0) 4-12 (102-305) 36 (136.3) 44 (166.6) 20.2 (1,4) 30.2 (2,1) 16 x 22 (4.9 x 6.7) 175°F (78°C) 4-12 (102-305) 39 (147.6) 48 (181.7) 23.8 (1,6) 36.0 (2,5) 16 x 24 (4.9 x 7.3) 4-12 (102-305) 33(124.9) 17.0(1,2) 18 x 18(5.5 x 5.5) 135°F (57°C) 4-12(102-305) 39(147.6) 23.8(1,6) 14 x 26(4.3 x 7.9) 135°F (57°C) 4-6(102- 153) 40(151.4) 25.0(1,7) 18 x 22(5.5 x 6.7) 135°F (57°C) 4-12(102-305) 46(174.1) 33.1 (2,25) 14 x 26(4.3 x 7.9) 135°F (57°C) 1,2 1,2 6-12(153-305) 33(124.9) 17.0(1,2) 18 x 18(5.5 x 5.5) 155°F (68°C) 4-12(102-305) 40(151.4) 25.0(1,7) 18 x 22(5.5 x 6.7) 155°F (68°C) 4-12(102-305) 46(174.1) 33.1 (2,25) 14 x 26(4.3 x 7.9) 155°F (68°C) 6-12(153-305) _ (I)FM Approval of recessed sprinkler-135°F(57°C)and 155°F(68°C)only. (2)Refer to escutcheon data table for dimensions. FACE OF FITTING TO(2) CEILING DIMENSION 1/8 \ 4"TO 12" 1\ TURN SPRING COLLAR, l.UMI UNTIL TIGHT AGAINST = , ii SPRINKLER WRENCH BOSS. 1 15//B" IIIIIIIIIIII`'Ii 2 27/32"DIA. DIA 000000U 1-11.1 c - I RECOMMENDED WALL HOLE A"(2) 2 1/4"DIAMETER 59FG02 ADJUSTMENT(2J 14826'02 olti OFpi ! Installation Sprinkler Types Quick response sprinkler are intended for installation as Extended Coverage Pendent114. d ,..„, specified in NFPA 13. Quick response sprinklers and stan- Extended Coverage Sidewall # ,47dard response sprinklers should not be intermixed. • EC-9 HSW Deflector The Model F1FR QREC Recessed Sprinklers are to be in- Recessed Extended Coverage Pendent 7.0 1.11.7 J "55b stalled as shown. The Model Fl or F2 Escutcheons illus- Recessed Extended Coverage Sidewall igO] trated are the only recessed escutcheons to be used with • EC-9 HSW Deflector the Model F1FR QREC Sprinklers. The use of any other Finishes(') Vail Fire 09/29/16&Emergency Services recessed escutcheon will void all approvals and negate all Standard Finishesto warranties. Sprinkler Escutcheon When installing Model F1FR QREC Sprinklers, use the Bronze Brass Model D Sprinkler Wrench. When installing Model F1FR Chrome Chrome QREC Recessed Pendent or Recessed Sidewall Sprinklers, 1White&Black Polyester)3) White use the Model GFR1 Sprinkler Wrench. Any other type of pecial Application Finishes wrench may damage these sprinklers. Sprinkler(2) Escutcheon Glass bulb sprinklers have orange bulb protectors to Electroless Nickel PTFE(3) Electroless Nickel PTFE minimize bulb damage during shipping, handling and in- Bright Brass Bright Brass stallation. REMOVE THIS PROTECTION AT THE TIME THE Black Plating Black Plating SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE Black Paint Black Paint Off White Satin Off White PROTECTION. Removal of the protectors before this time Chrome Chrome Dull may leave the bulb vulnerable to damage. RASCO wrench- (1)Other colors and finishes are available on special order. Consult es are designed to install sprinklers when covers are in factory for details. place. REMOVE PROTECTORS BY UNDOING THE CLASP (2)FM Approval limited to bronze,bright and satin chrome plated, BY HAND. DO NOT USE TOOLS TO REMOVE THE PRO- and polyester coated only. mcULus Listed Corrosion Resistant Sprinkler TECTORS. Maintenance Escutcheon Data The Models Fl FR QREC and Fl FR QREC Recessed Sprin- Face of Fining klers should be inspected and the sprinkler system main- Model°n Adjustment Dimension to Ceiling or tained in accordance with NFPA 25. Do not clean sprinklers Wall Dimension with soap and water, ammonia or any other cleaning fluids. Fl 3/4"(19mm) 3/4"(19mm)�(2 s'(5mm) I Remove dust by gentle vacuuming. Replace any sprin- 1 /6 (35mm) 15/16"(24mm) kler which has beenpainted (other than factoryapplied) or F2 1/2" 13mm 1" (25mm)1) 3/,s'(5mm) pp ) ( ) 19/16"(40mm))2) 11/16' (18mm) damaged in any way. A stock of spare sprinklers should be EC Pendent maintained to allow quick replacement of damaged or op- (2)Ec Hsw erated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used Ordering Information to minimize the potential for damage to sprinklers that would Specify: cause improper operation or non-operation. 1. Sprinkler Model: Fl FR QREC 2. Sprinkler Type Temperature Ratings 3. Temperature Rating Sprinkler Maximum 4. Sprinkler Finish Classification Rating Ambient Temp. Bulb 5. Thread Type: [3/4" NPT] [ISO 7-1R3/4] °F °C °F °C Color 6. Escutcheon Type Ordinary 135 57 100 38 Orange 7. Escutcheon Finish (where applicable) Ordinary 155 68 100 38 Red I Note: When Model F1FR Recessed sprinklers are or- Intermediate 175 79 150 66 Yellow p dered, the sprinklers and escutcheons are pack- Maximum Working Pressure aged separately. 175 psi(12 bar) SIN R4842&R4862 cULus listed for 250 psi(17 bar) 100% Factory tested hydrostatically to 500 psi (34.5 bar) The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years,and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries. Manufactured b Reliable Automatic Sprinkler Co.,Inc. h Recycled Reliabi ® (800)431-1588 Sales Offices % Paper (800)848 6051 a Sales Fax (914)829 2042 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.12/15 P/N 9999970142