Loading...
HomeMy WebLinkAboutF16-0057_specs.pdf 444 a: tLjCQ 00, Worldwide tco-fir-y .www #11F Fire Protection Contacts —. 010j Products Products Vail Fire&Em- gency Services n9/30/1 f_ RAPID RESPONSE Series LFII Residential 4.9 K-factor Concealed Pendent Sprinkler Flat Plate, Wet Pipe and Dry Pipe Systems General The Series LFII Residential Concealed Pendent Sprinklers (TY3596) has Description been designed with heat sensitivity and water distribution characteristics TYCO RAPID RESPONSE Series LFII proven to help in the control of residen- tial fires and to improve the chance for occupants to escape or be evacuated. Sprinklers (TY3596) are decorative, fast response,fusible solder sprinklers The Series LFII Residential Con ' designed for use in residential occu- cealed Pendent Sprinklers (TY3596) panties such as homes, apartments, are shipped with a Disposable Pro- • dormitories, and hotels. tective Cap. The Protective Cap is The cover plate assembly conceals temporarily removed for installation, the sprinkler operating components and then it can be replaced to help above the ceiling.The flat profile of the Protect the sprinkler while the ceiling NOTICE cover plate provides the optimum aes is being installed or finished.The tip of thetically appealing sprinkler design. the Protective Cap can also be used The Series LFII Residential Concealed In addition, the concealed design of to mark the center of the ceiling hole Pendent Sprinklers(TY3596)described the Series LFII Residential Concealed into plaster board, ceiling tiles, etc, herein must be installed and main- Pendent Sprinklers (TY3596) provides by gently pushing the ceiling product tained in compliance with this docu- 1/2 inch(12,7 mm)vertical adjustment. against the Protective Cap. When the ment and with the applicable standards This adjustment provides a measure of ceiling installation is complete the Pro- of the National Fire Protection Associa- flexibility when cutting fixed sprinkler tective Cap is removed and the Cover tion(NFPA),in addition to the standards drops. Plate Assembly installed. of any authorities having jurisdiction. to The Series LFII Residential Concealed Dry Pipe System Application Failure of these devices. Sprinklers are intended for use in the The owner is responsible scenarios: Pendent Sprinklers offers a laboratory for main- approved option for designing dry pipe taining their fire protection system • wet and dry pipe residential sprin- residential sprinkler systems,whereas, and devices in proper operating con- kier systems for one- and two-fam- most residential sprinklers are labora- dition. Contact the installing contrac- ily dwellings and mobile homes per tory approved for wet systems only. tor or product manufacturer with any NFPA 13D questions. Through extensive testing, it has been • wet and dry pipe residential sprinkler determined that the number of design systems for residential occupancies sprinklers (hydraulic design area) for Sprinkler up to and including four stories in the Series LFII Residential Concealed height per NFPA 13R Pendent Sprinklers (TY3596) need Identification • wet and dry pipe sprinkler systems not be increased over the number of r the residentialdryipeportions s f ons design sprinklers (hydraulic design Number (SIN) fooccupancy per NFPA 13 area)as specified for wet pipe sprinkler systems,as is accustomed for density/ TY3596 area sprinkler systems designed per NFPA 13. Consequently,the Series LFII Residen- tial Concealed Pendent Sprinklers offer the features of non-water filled pipe in IMPORTANT addition to not having to increase the Always refer to Technical Data number of design sprinklers(hydraulic Sheet TFP700 for the "INSTALLER design area) for systems designed to WARNING"that provides cautions NFPA 13,13D, or 13R. with respect to handling and instal- lation of sprinkler systems and com- ponents_ Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situationor cause it to operate prematurely. Page 1 of 6 FEBRUARY 2015 TFP442 Wel OF irk! TFP442Itv it Page 2 of 6 , S 110 b BODY rb SEALING WRENCH J 1#15 (112" NPT)----------__ A --- - ASSEMBLY RECESS Vail Fire&Emergency Services CAP I_ l� SPRINKLER /-4994 l WRENCHINGiiiiiiiio" i SADDLE IAli I = : AREA I Illkli tkl. LII i LI PUSH WRENCH SUPPORT COMPRESSION IN TO ENSURE CUP WITH �� { SCREW ROLL FORMED tk Ism ` ENGAGEMENT WITH SPRINKLER THREADS \ WRENCHING AREA / II LEVER FIGURE 2 .2/ 114,h W-TYPE 18 GUIDE I 'it.a�� SPRINKLER WRENCH PIN 1111/11M•11111• 1=1111 SOLDER LINK ELEMENT GUIDE PIN HOUSING : ] 1I - DEFLECTOR _ i (OPERATED DEFLECTOR - POSITION) SPRINKLER/SUPPORT CUP ASSEMBLY THREAD INTO j RETAINER SUPPORT WITH THREAD CUP UNTIL iI DIMPLES MOUNTING t Q 0 I� SURFACE IS FLUSH WITH CEILING EJECTION \ SPRING SOLDER-////////{ COVER PLATE/RETAINER COVER TAB ASSEMBLY PLATE FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLER(TY3596) 2-1/2" DIA. SPRINKLER- (63,5 mm) /� 1/2,(12,7 mm) FACE OF SUPPORT CUP 1/2" \ 1 THREADED SPRINKLER ASSEMBLY NPT )___ \ ADJUSTMENT FITTING r OPERATED �- } SPRINKLER - F 1 7/8"±1/4" -=-------- COVER 11 11.1- (47-----=---flEr ,6 mm PLATE S)S I I 1/8' GAP ±6,4 mm) RETAINER (3,2 mm) ____________, - �171 _ _ = - COVER- SPRINKLER- MOUNTING 7/8"(22,2 mm) Il RETAINER SUPPORT CUP 3/16" SURFACE 1-1/8"(28,6 mm) �1 ASSEMBLY ASSEMBLY ` \\.= - 0 . . . • ,.,. tqco N. .....",... - Worldwide www.tyco-fir- #1,, Fire Protection Contacts -.-112 Products Vail Fire&Em gency Services 09/30/16 RAPID RESPONSE Series LFII Residential Sprinklers 4.4 K-factor Horizontal Sidewall Wet Pipe Systems General which the pipe nipples to the sprinklers must be cut. Description The Series LFII Residential Sprinklers • has been designed with heat sensitivity The TYCO RAPID RESPONSE Series and water distribution characteristics LFII Residential Horizontal Sidewall proven to help in the control of residen- Sprinklers (TY2334) are decorative, tial fires and to improve the chance for 1± fast response,frangible bulb sprinklers occupants to escape or be evacuated. designed for use in residential occu- pancies such as homes, apartments, NOTICE 14 dormitories,and hotels.When aesthet- " its and optimized flow characteristics The Series LFII Residential Horizontal are the major consideration,the Series Sidewall Sprinklers(TY2334)described LFII Residential Sprinklers (TY2334) herein must be installed and main- should be the first choice. tained in compliance with this docu- ment and with the applicable standards The Series LFII Residential Sprinklers of the National Fire Protection Associa- are intended for use in the following tion,in addition to the standards of any scenarios: authorities having jurisdiction. Failure • wet pipe residential sprinkler sys to do so may impair the performance terns for one-and two-family dwell- ings and mobile homes per NFPA The owner is responsible for maintain-13D ing their fire protection system and • wet pipe residential sprinkler sys- devices in proper operating condition. /:.--4e I., . tems for residential occupancies up The installing contractor or sprinkler " to and including four stories in height manufacturer should be contacted with , per NFPA 13R any questions. • wet pipe sprinkler systems for the Sprinkler � residential portions of any occu- pancy per NFPA 13 Identification The recessed version of the Series Number (SIN) LFII Residential Sprinklers is intended for use in areas with finished walls. It employs a two-piece Style 20 Recessed TY2334 -- Escutcheon. The Recessed Escutch- eon provides 1/4 inch (6,4 mm) of Technical �� ° recessed adjustment or up to 1/2 inch (12,7 mm)of total adjustment from the Data flush mounting surface position. The adjustment provided by the Recessed Approvals Temperature Rating Escutcheon reduces the accuracy to UL and C-UL Listed 155°F(68°C)or 175°F(79°C) Certified to all requirements of Finishes NSF/ANSI 61 Natural Brass,Signal White,or Chrome Plated IMPORTANT (Refer to the Design Criteria section for physical Characteristics Always refer to Technical Data details on these approvals.) Frame Brass Sheet TFP700 for the "INSTALLER Maximum Working Pressure Button Bronze WARNING" that provides cautions Maximum 175 psi(12,1 bar) Sealing Assembly. Beryllium Nickel tiv/TEFLON with respect to handling and instal- Bulb 3 mm Glass lation of sprinkler systems and com- Discharge Coefficient Compression Screw Bronze ponents. improper handling and K-4.4 GPM/psi''2(63,4 LPM/bart'z) Deflector Copper installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 JANUARY 2016 TFP412 4,4 TFP412 � C Page 2 of 6 ,TM ir Components: WRENCH '33 I Frame ► i FLATS 2 Button r�l �l11I1 I' WRENCH 1 3 - Sealingo �11�; FLATS Vail Firs&Emergency Services TOP-OF- _(° !! Fa 09/3011 Assembry DEFLECTOR ` '1 1) 1/2° NPT Ell 4 - Bulb �������� 5 Compression y1+ 7116"(11,1 mm) �`- Screw �-- NOMINAL 2-7/8" DIA. 6 - Deflector* 6* 5 4 2 MAKE-IN I � (73,{3 mm) P CENTERLINE ! *Temperature rating — Emran T.. -'-ter ' OF WATERWAY is indicated on top , 6�. of Deflector. 7/16" 1 1 STYLE 20 - (11,1 mm) - 3 RECESSED $ 1-1/2° ESCUTCHEON END-OF- 'W(38,1 mm) ESCUTCHEON DEFLECTOR 2-1/8" PLATE SEATING BOSS (54,0 mm) SURFACE RECESSED FIGURE 1 RAPID RESPONSE SERIES LF11 RESIDENTIAL HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS(TY2334) 7/16±1/8" el (11,1±3,2 mm) MOUNTING FACE OF WRENCH RECESS SURFACE SPRINKLER (END"A" USED FITTING FOR TY2334) TOP-OF- CLOSURE I DEFLECTOR J IFIGURE 3 i, TY2334 W-TYPE 6 SPRINKLER WRENCH 2-7/8' DIA. (73,0 mm) WRENCH I� r I F 2-1/4" DIA. (57,2 mm) RECESS 7/16" -.- (11,1 mm) iiI MOUNTING 11 IA 1 — f NI if PLATE END-OF- DEFLECTOR1/8" BOSS I (3,2 mm) PUSH WRENCH 1-1/4" (31,8 mm) - 1/2" (12,7 mm) IN TO ENSURE - ENGAGEMENT 1"(25,4 mm) 1/4' (6,4 mm) WITH SPRINKLER FIGURE 2 WRENCHING AREA STYLE 20 RECESSED ESCUTCHEON FIGURE 4 FOR USE WITH THE RAPID RESPONSE SERIES LFII W-TYPE 7 RECESSED RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER(TY2334) SPRINKLER WRENCH