Loading...
HomeMy WebLinkAboutF16-0054_FP-1 Plans Approved.pdf 44 " °F 1'4 Light Hazard•0.100gpm/ft2 for 1500.00ft2 P o___ Hanger No.01S I, / �,_`® Top Beam C-Clamp 141 N .•�`�, Steel I-Beam or Modell300Michigan Western States I N7 1- r OP / 4,1:1111V ` 4P` Bar Joist i orEBeam C-Clamp 4 f}F I / �111-1 per �i ®i:z. ,/--41e % e� with Lock Nut Fire Protection Co. 0 INN I ExraTnrG STAARS '3' I iE. All 7026 South Tucson Way N I(D TO RET-1.40•4 Rounded to ThreadCeriieaolel,Colorado 30112 ,' Nearest Inch Q e Rodmil Fire&Emergency Services •J ! e Tel.'303.792-0022 Fat:303.79929039 0/30/16 / �^ . _� o CnlcrarbStaNrR �llalKmNunthcr032 \/ �:' l /�`` k' . ` IIIIIIIIapproved forinstall'`�'��/©' Li _ ` Pipe�l•�': A<r►4'�� � , Ogr ` 1/4 • Swvel Rin• i., - .,,,„;,..... , i o I. x o ��- ' � ®'O µ'=,• Note on Plan:Hanger Number and"A•Dimension -O•.*•y liAleminieiri ✓ v li t \ ""_� Nio ��� '„ HANGER DETAIL(N.TS) r1 N E.XrtlTlr rDnR x __\_ _ rig, - , �"'� END OF PHAS N I rib SPORTS 111—AREA OF WORK 4 (e 11/4 FEED FROM BELO 7 •ING FUTURE CONSTRUCTION) m 111111 ® b �• O9'-51/z y \\ /�Pepis[�,p8,' �' 7io _ V zp ry p pr8sekl Austr a., ✓� rDROP DOWN TO . START OF PHASE TWO F1 �� o a FEED HEADS IN I . 11/2 \ i r - ••'......t 3+d ins vCRAWL SPACE 411 �2 P 11/� 1 _. �� • o4'-33/ . 43/4 1 L . 5'- '/a o0 Creek Dr % O < a N N 11/2 w Thomas ha CoatleYCET H 1-------'<, O 11:117 (11 2 ' (34i-53/ jpil W.s+an NICET Level III on G. - ❑ rI t _ — Vail Ville e Y y �:� � • — — -� ReIMCET L vel III 9 • • e�. `'� sewueY� 7 Antiques-Gifts Rt \ ArtonAWhimG-ge:v z«a<a< E)c1STT16 ISM S ./ Q - r DRAWN BY: TYLER WILLIAMS DAR SP) 7 Alp /.� t__■— : ' DATE: 6/17/2016 t As� I 1 I �] ,,.� �� 1 _ _ VICINITY MAP 11T1---i-'I SCALE 1/8"=1'-0" SCALE: 1/8"= 1' Z d CRAWL SPACE UNDER BAR FOYER(PHASE TWO) /� Derated Flow Test Data GENERAL NOTES 4, O P 11/2 O P 11/2 • PStatic Pressure 135.000 Q ,o' 0 Residual Pressure: 59.000 FIRE PROTECTION SYSTEM TENANT IMPROVEMENT w W / Flow 1435.00 1) MODIFY THE EXISTING SYSTEM IN SUITE TO COMPLY WITH NEW WALL AND CEILING a+ L , ()POSED FLOOR ABOVE I0124 / CONFIGURATION. U U W Outside Hose Flow 250.00 g W / 2) NEW PIPING SHOWN AS SOLID RED LINE. EXISTING PIPING SHOWN AS DASHED RED LINE. d' W 1_ L U .1 3) SYSTEM TO BE DESIGNED, INSTALLED,AND TESTED PER NFPA 13,2013 EDITION. = 0 d Z 4) EXISTING SYSTEM DESIGNED FOR LIGHT HAZARD OCCUPANCYc_ r4 5) NO MORE THAN TWO SPRINKLERS TO BE PIPED FROM ANY 1"OUTLET. 0. '� cn 6) ALL DROPS TO BE USING 1"BLACK STEEL PIPE. WN 7) ALL PAINTING OF PIPE TO BE DONE BY OTHERS, PER CONTRACT. aP4 8)AFTER SYSTEM TURNOVER IT IS THE OWNER'S RESPONSIBILITY TO INSPECT,TEST, AND r4 MAINTAIN THE SYSTEM IN ACCORDANCE WITH NFPA 25. Hydraulic Information 9)PER OWNER AND AHJ,SYSTEM TO BE INSTALLED BUT NOT ACTIVE UNTIL SUPPLY IS CONNECTED Y DURING FUTURE CONSTRUCTION. CONTRACT NUMBER OCCUPANCY CLASSIFICATION Light Hazard — CS2867 DENSITY 0.100gpm/ft2 for 1500.00ft2(Actual 965.43ft2) DRAWING FILE NAME TOTAL HOSE STREAMS 250.00 FIRE SPRINKLER LEGEND PEPI'S BAR-PHASE TWO FLOOR/AREA TOTAL HEADS FLOWING 15 SYMBOL MANUFACTURER MODEL TYPE RESPONSE K-FACTOR THREAD SIZE TEMPERATURE FINISH TRIM STYLE TRIM FINISH QUANTITY PHASE TWO K-FACTOR 5.6 O RELIABLE G5-56 CONCEALED QUICK 5.6 1/2" 155° BRASS CONCEALED WHITE 12 SHEET NUMBER TOTAL WATER REQUIRED 623.99 O - RELIABLE G5-56 CONCEALED QUICK 5.6 1/2" 155° BRASS CONCEALED WHITE 6 flit TOTAL PRESSURE REQUIRED 78.138 SAFETY MARGIN(psi) +40.580(34.2%) TOTAL 18 FP-01 1 OF 1 PLAN NORTH