Loading...
HomeMy WebLinkAboutF16-0047_FP1 plans approved.pdf ° Ci I/4 4,•70011111101Z4-*114 AMCEEC P79 TOWN O` A MP Vail Fire&Emergency Services 09/20/16 Western States •--.4.9y • . . •A tr Fire Protection Co. , ~Spradd/e Creek Rd �rddd, T S 274 Center Drive �o�/d9P y *, SpraddleCreekRd RpNTgGE Igpgp E Glenwood Sptings, Colorado 81601 6) Approvedas leO Tel.: 970-618-3294 Fax: 970-945-9504 W i S Frontage Rd W I i 0 O Colorado State Registration Number: 032 Eagle Valley Pharmacy _ A } 176 • t R-CEILING SYSTEMS, NONCOMBUSTIBLE Four Seasons S Fronta ot FILE NOiir, , .FC 1110 GENERIC 1 HOUR Private Residences"bat. 9e Rd E S Fronta G GYPSUM WALLBOARD,STEEL JOISTS,CONCRETE SLAB FIREV I I W Meadow Dr -1 i.e.(The Seb•• ail age Rd E W Kelly Liken S Fro, One layer 1/2"type X gypsum wallboard or gypsum veneer base applied at right angles MeaclowDr E Meadow Dr to rigid board and Joints locatedchannels 2midwaywith 1"Type between continuous chascrews nnn s and attached toGypsum Campoue Fior, additional pieces of channel 52"long with screws 8"o.c.Fuming channels wire Led to 6k YI open web steel joists 24'Data supporting 3/8"rib metal lath or 9/16'deep 28 gage re Gra E Meadow pr I n ri corrugated steel and 2"concrete slab measured from top of flute (f assed 90 minute • fire test restrained and unrestrained.) _ . __ GD • EMea �� __ SITE LOCATION f Austria Haus is Club&Hotel w Starbucks i Sonnenalp o UNIT #204 REMODEL ry GENERAL NOTES 44o y Weight:Ceding 2 psi ,eek F3ert Ford Alpine Gardens G°re Creek .- Wilio� Fire Test UL Design 8-12 4, • UL Design G502 o GoreCreekDr 1. THE SCOPE OF WORK IS TO RETROFIT AWET PIPE FIRE SPRINKLER SYSTEM IN UNIT#204 PER NFPA 13R 2010. Forest Rd NiiiowR coPIPING IS BEING INSTALLED FOR FUTURE SPRINKLER SYSTEM TIE IN. Ra ,ap vv cl) Red I 2. BUILDING IS AN EXISTING FOUR STORY RESIDENTIAL BUILDING WITH CONCRETE AND STEEL BEAM 1– CONSTRUCTION. THE BUILDING IS PARTIALLY SPRINKLER WITH SPRINKLERS BEING INSTALLED AS UNITS GET REMODELED. ' w 3. RESIDENTIAL SPRINKLERS WILL BE INSTALLED THOUGH-OUT THE UNIT. THE SYSTEM IS CALCULATED BASED ON Z ± o VICINITY MAP THE MOST DEMANDING 4 HEADS WITHIN ACOMPARTMENT WITH A0.1 GPM/FT2 DENSITY AT 14X14 SPACING. LT 1– SCALE: SCALE: N.T.S. 4. THE NEW PIPING IS TO BE COPPER,AND SHOWN AS SOLID RED LINE, EXISTING PIPE SHOWN AS DASHED RED c LINE. W f SITE PLAN 03555. NEW PIPING WILL BE DESIGNED, INSTALLED,AND TESTED PER NFPA 13R 2010 ED. 6.ANY REQUIRED WIRING OF DEVICES,AND FIRE ALARM SYSTEM WORK SHALL BE PROVIDED BY OTHERS PER a SCALE: N.T.S. CONTRACT. 7. TENTING AND INSULATION BY OTHERS PER CONTRACT. 8. OWNER TO PROVIDE ADEQUATE HEAT OR INSULATION TO PREVENT WET PIPING FROM FREEZING. 9. DRILLING HOLES THROUGH STEEL OR FINISHED CEILING BEAMS TO BE DONE BY OTHERS. 10. EXISTING PIPING IS SHOW AS DASHED LINES. 1- z w 0 z w a Hydraulic Information w OCCUPANCY CLASSIFICATION Residential a DENSITY 0.10gpm/ft2 for 900.00ft2(Actual 483.59ft2) J w 53'-11'/z TOTAL HEADS FLOWING 4 0 o / K-FACTOR 4.9 a 13'-5'/z 9'-0 11'-0 20'-6 TOTAL WATER REQUIRED 181.5 re 0 m N confirm bathroom size TOTAL PRESSURE REQUIRED 81.6 w w -- EA,* Vo Ify. 01 SAFETY MARGIN(psi) +57,9(41.5%) a O 1'-t V-1 P%: Resid; tial o anger o. 5'. 5ft2 Inverted Top Beam C-Clamp(Beam) 1 6 SAMMY SCREW 03 BEDROOM i 0 BEDROOM ONE SIDE SAMMY SCREW LIVING ROOM Steel 1-Beam o sidesammysereew AND ROD COPPER PIPE HANGER SPACING 0 V I■ >- (V / ur (�1 ■issomn" , W 1 o 9' Bar Joist —\ e ost PIPE SIZE MAX HANGER SPACING FASTERNER HEX HEAD SIZE } iv rn R sid: I dliesid: tial ih in O iiiii�iiiiiii Round to a e = - 1" 6'-0" 5/16" m ~ F-- / J 10ft 1,1 Z Nearest Inch" a All m y =- Sammy Screew U BATH ( �/� e Thread Zo 1.7i1-1/4" 7'-0" 5/16" 4111) –,m Mode1300 Michig All IIIIIIII Rod t=,t r.� Tot Beam C-Clamp Thread lffa Rounded to ° 3/8" \ or Equal Rod o : Nearest Inch pie �;., Round to ¢ All o Pre-Drill Hole 1-112" 8'-0" 5116" with Lock Nut _ \\\ p Nearest Inch. Thread l■ Swivel Ring�'�'•. Rod 2" 8'-0" 5/16" r /. Ill VIII ' 1:7--5% 13'-0 2'-0 3'-0 10'-10%: Pipe " °� Z N Swivel R• ing _ j Pipe o_ 0 CI �� SwivelRing Note on Plan:Han er Number and'A'Dimensiont2"M )o11PSi \ HANGER DETAILS 0) a o { - r T SCALE: N.T.S. 5 o 1_ r Note on Plan:Hanger Number and'A'Dimension Note on Plan:Hanger Number and'A'Dimension re W KITCHEN 0 MASTER BEDROOM o) CV 0 \ in 0 CD O 0 q EX 4" STANDPIPE 1D1 T "' UP FROM BELOW :I–. 10. / 411: i �/ EN—RY 4" FEED TO SYSTEM C C C C C C . m 6) O y�6 Aft c .5 Tr / DRAWN BY:TYLER WILLIAMS DATE: 8/18/2016 BAT I 4 4 + Resid: tial 2 r 48'-11% 3r-4 4 4 0W 1 0 1e'ai I 0 TRANSITION N " al �'�-- FROM a 0 O STEEL TO Q I 0 COPPER N (?� • t �t. r N �— 0 16'-3 4 q 4"AMES COLT 400 RP OSY BACKFLOW '. 4 1 2nd FLOOR - UNIT 204 FIRE SPRINKLER LAYOUT I . . .:. it L-, . LIT PRV —.,1l L,1:3 ed ern S�ti Fire r role ran C"{•r NOT\ veaENnLYRM INSTALLED B0 Eovh FOR HYDFAuucs) Sit r • Q- SCALE: 1/8" = 1 '-0" NILL��T Leo] CIL • ' Q Ri isiralion.II]'.'•851 I , • N O nn Iyer I lam LewdQ O v U v v DASHED PIPING ON I -n--3 Q - W GARAGE LEVEL BUILDING RISER DETAIL 0-3 > O srrn — BELOW124 a r • W 0 Q J J DERATED FLOW DATA > Water Supply Data Data Supplied by Vail FD Static Pressure 150 psi I CONTRACT NUMBER 4 Residual Pressure 15.090 psi CS2888 � 13'-8Flow 721 GPM �7 OOO 10 From Previous Remodel DRAWING FILE NAME - Location:Village Inn Plaza 6 VILLAGE INN PLAZA 4204 !'CD O 6 �° tk 2 SHEET NUMBER #: 4--\ 72'-1 4F�4111 ' Fire EX6" RP DOUBLE 10 ' Sprinkler Plan CHECK BACKFLOW PREVENTER EX 6" DI 7 UNDERGROUND FP- 1 of 1