Loading...
HomeMy WebLinkAboutF16-0037 cut sheets r }iL7r ,r 1 { I-Il TCI-IYIJ I Ei. I IU1 I 15-092 PROJECT SUBMITTAL Fire Sprinkler MORRIS RESIDENCE 4842 MEADOW LANE VAIL, CO 2264 G Road, Grand Junction, CO 81505 Phone: (970)434-4803 Fax: (970)434-0802 EXCEL FIRE PROTECTION SUBMITTAL INDEX MORRIS RESIDENCE 4842 MEADOW LANE VAIL,CO Fire Protection Product Data Index EXCEL JOB NUMBER 15-092 Item Description Model 1. Fire Protection Drawings FP-1 2. Hydraulic Calcs Remote Area#1 3. Backflow Preventer Conbraco Series 40-100 4. Flow Switch Potter Model VSR-SF 5. Overhead fire protection sprinkler piping per Type-M Copper 6. Overhead fire protection fittings Copper 7. Riser fire protection piping per 2"and smaller to be Mega-Thread 8. Riser fire protection threaded fittings Anvil 9. Check,Globe,&Ball valves United Brass 10. Pendant Sprinklers VK457,4.9K,QR, 3/4", 155°F 11. Pendant Sprinklers VK457,4.9K,QR, '/z",200°F 12. Fire Dept. Connection Croker Model 6341 13. Hangers Tolco 14. Spare head cabinet As Required 15. Identification Signs As Required 2264 G Road Grand Junction, CO 81504 Phone: (970)434-4803 Fax: (970)434-0802 Hydraulic Calculations for Project Name: Morriss Residence Location:4842 Meadow Lane, , Vail, CO Drawing Name: Calcs copper Calculation Date: 6/13/2016 Design Remote Area Number: 1 Remote Area Location: Upper Level Bedroom/Sewing Room Occupancy Classification: Residential Commodity Classification: Residential Density: 0.050gpm/ft2 Area of Application: 900.00ft2(Actual 313.60ft2) Coverage per Sprinkler: 256.00ft2 Type of sprinklers calculated: Pendent No. of sprinklers calculated: 3 Type of System: Wet Volume of Dry or PreAction System: N/A In-rack Demand: N/A gpm at Node: N/A Hose Streams: 0.0 gpm at Node: 1 Type: Allowance at Source Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 44.97 @ 85.541 Water Supply Information: Name of Contractor: Excel Fire Protection Address: 2264 G Road, Grand Junction, CO Phone Number: Name of designer: Joshua Smith Authority Having Jurisdiction: Notes: Automatic peaking results Left: 85.541 Right: 85.541 M.E.P.CAD, Inc. i���AutoSPRINK® 12 v12.0.48.0 1 6/13/201611:28:51AM Page 1 Hydraulic Graph Job Name: Morriss Residence N 1.85 Remote Area Number: 1 Date: 6/13/2016 100 I I � Static Pressure 98.000 Water Supply Summary Sheet 90 Node: 1 1309.50 @ 88.000 44.97 @ 85.541 80 70 60 .N a System demand curve fa 50 U, U, a` 40 30 20 -S 10 0 1111 I I I I I 0250 500 750 1000 1250 1500 1750 2000 2250 2500 Flow-gpm �M ©M.E.P.CAD, Inc. AutoSPRINK®12 v12.0.48.0 6/13/2016 11:28:53AM Page 2 iii -Summary Of Outflowing Devices I Job Number:15-092-15-092 Report Description:Residential(1) Actual Flow Minimum Flow K-Factor Pressure Device (qpm) (qpm) (K) (psi) Sprinkler 101 14.74 13.00 4.9 9.044 Sprinkler 102 17.23 13.00 4.9 12.364 * Sprinkler 103 13.00 13.00 4.9 7.039 E> Most Demanding Sprinkler Data E,©M.E.P.CAD,Inc. in AutoSPRINK®12 v12.0.48.0 6/13/2016 11:28:54AM Page 3 Job Name: Morriss Residence Remote Area Number: 1 Date: 6/13/2016 Supply Analysis Static Residual Flow Available Total Demand Required Pressure Node Name (psi) (psi) @ @ (gpm) (psi) (gpm) (psi) 1 Water Supply 98.000 88.000 1309.50 97.980 44.97 85.541 Node Analysis Node Number Elevation(Foot) Node Type Pressure at Discharge at Notes Node Node (psi) (gpm) 1 -10'-0 Supply 85.541 44.97 101 27'-61/4 Sprinkler 9.044 14.74 102 27'-61/4 Sprinkler 12.364 17.23 103 27'-61/4 Sprinkler 7.039 13.00 2 7'-6 58.784 3 8'-0 58.455 4 2'-6 62.826 5 0'-0 76.017 6 8'-0 58.087 7 18'-0 33.111 8 8'-0 43.511 9 18'-0 28.929 10 28'-0 15.104 11 28'-0 15.103 12 28'-0 9.507 13 18'-0 32.154 14 8'-0 42.628 15 18'-0 31.387 LM,©M.E.P.CAD, Inc. di AutoSPRINK®12 v12.0.48.0 6/13/2016 11:28:56AM Page 4 Job Name: Morriss Residence Remote Area Number: 1 Date: 6/13/2016 Pipe Information Flow added Length C Factor Notes Elev 1 Fittings& Total(Pt) Node 1 K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (Foot) (q) Length) Fitting Pf Friction Elev Pe ( ) Fixed Pressure Losses,when Elev 2 Total Flow Equiv. (Foot) Loss Per Unit applicable,are added directly Node 2 Actual ID Length Total (Foot) (Q) (Foot) (psi) Friction(Pf) to(Pf)and shown as a (Foot) negative value. 103 27'-61/4 4.9 13.00 3/4 (See 16'-8'% 150 7.039 Route 1 Notes) Sprinkler, 3'-0 -0.208 0.135904 E(1'-0),T(2'-0) 12 28'-0 13.00 0.8110 19'-8'/4 2.676 12 28'-0 14.74 3/4 (See 7'-13/4 150 9.507 Notes) Flow(q)from Route 2 3'-0 0.552153 E(1'-0),T(2'-0) 10 28'-0 27.74 0.8110 10'-13/4 5.597 10 28'-0 0.48 3/4 (See 12'-7% 150 15.104 Notes) Flow(q)from Route 3 4'-0 4.335 - 0.569853 2E(1'-0),T(2'-0) 9 18'-0 28.21 0.8110 16'-73/4 9.490 9 18'-0 % (See 12'-1 150 28.929 Notes) 4'-6 -0.000 0.194429 2T(2'-0),Tr(0'-6) 13 18'-0 15.78 0.8110 16'-7 3.225 13 18'-0 10.84 3/4 (See 10'-0 150 32.154 Notes) Flow(q)from Route 5 2'-0 4.335 14 8'-0 26.61 0.8110 12' 0 0.511507 6.138 T(2'-0) 14 8'-0 % (See 41'-3'% J 150 42.628 Notes) 3'-6 0.345313 3Tr(0'-6),2E(1'-0) 6 8'-0 21.52 0.8110 44'-9'/4 15.460 6 8'-0 1 (See 1'-0 150 58.087 Notes) 4'-0 0.217 0.095919 E(2'-0),T(2'-0) 2 7'-6 21.52 1.0550 5'-0 0.480 5'-0 150 58.784 2 7'-6 23.44 1 Flow(q)from Route 4 2.168 4 2'-6 44.97 1.0550 0.374929 5'-0 1.875 4 2'-6 1 (See 5'-6% 120 62.826 Notes) 4'-9 1.084 0.489817 2E(2'-4'/2), BFP(-7.052) 5 0'0 44.97 1.0870 10'-33/4 12.107 5 0'-0 1% (See 35'-0 120 76.017 Notes) 3'-4% 4.335 1 -10'-0 44.97 1.4160 0.135143 E(3'-4%),S 38'-4% 5.190 0.00 85.541 Hose Allowance At Source 1 44.97 Total(Pt) Route 1 &©M.E.P.CAD,Inc. di AutoSPRINK®12 v12.0.48.0 1 6/13/2016 11:28:58AM Page 5 Job Name: Morriss Residence Remote Area Number: 1 Date: 6/13/2016 Pipe Information Flow added Length C Factor Notes Elev 1 Fittings& Total(Pt) Node 1 K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (Foot) - (q) Length) Fitting Pf Friction Elev Pe ( ) Fixed Pressure Losses,when Elev 2 Total Flow Equiv. (Foot) Loss Per Unit applicable,are added directly Node 2 Actual ID Length Total (Foot) Oa) (Foot) (psi) Friction(Pf) to(Pf)and shown as a (Foot) negative value. 101 27'-61/4 4.9 14.74 3/4 (See 2'-5 150 9.044 Route 2 Notes) Sprinkler, 1'-6 -0.208 - 0.171365 E(1'-0),Tr(0'-6) 12 28'-0 14.74 0.8110 3'-11 0.671 9.507 Total(Pt) Route 2 (See 8'-10'% 150 12.364 Route 3 102 27'-6'/4 4.9 17.23 3/4 Sprinkler, Notes) 4'-0 -0.208 11 28'-0 17.23 0.8110 0.228843 2E(1'-0),T(2'-0) 12'-101/2 2.947 11 28'-0 3/4 (See 2'4) 150 15.103 Notes) 1'-0 10 28'-0 0.48 0.8110 3 0 0.000301 0.001 2Tr(0'-6) 15.104 Total(Pt) Route 3 (See19'-7 150 33.111 Route 4 7 18'0 5.92+ 12.44 3/4 Notes) Flow(q)from Route 6 and 8 4'-0 4.335 0.257199 2E(1'0),T(2'0) 8 8'-0 18.35 0.8110 23' 7 6.065 8 8'-0 5.09 % (See 33'-5'% 150 43.511 Notes) Flow(q)from Route 9 3'-6 0.404592 3Tr(0'6),2E(1'0) 3 8'-0 23.44 0.8110 36'-11'/4 14.944 3 8'-0 1 (See 0'-6 150 58.455 Notes) 0'-6 0.217 2 7'-6 23.44 1.0550 I-0 0.112385 0.112 Tr(0'-6) 58.784 Total(Pt) Route 4 (See543/4 150 31.387 Route 5 15 18' 0 16.75 3/' Notes) Flow(q)from Route 7 2'-6 0.097040 Tr(0'-6),T(2'-0) 13 18'-0 10.84 0.8110 7'-103/4 0.767 32.154 Total(Pt) Route 5 15 18'-0 16.75 3/4 (See 46'-4% 150 31.387 Route 6 Notes) Flow(q)from Route 7 8'-0 7 18'-0 5.92 0.8110 3 0.031675 4Tr(0'-6),3T(2'-0) 54'-4% 1.723 33.111 Total(Pt) Route 6 11 28'-0 3/4 (See 44'-0 150 15.103 Route 7 Notes) 11'-0 4.335 0.217257 5E(1'-0),2T(2'-0),4Tr(0'-6) 15 18'0 16.75 0.8110 55'-0 11.949 31.387 Total(Pt) Route 7 &©M.E.P.CAD,Inc. di AutoSPRINK®12 v12.0.48.0 1 6/13/2016 11:28:58AM Page 6 Job Name: Morriss Residence Remote Area Number: 1 Date: 6/13/2016 Pipe Information Flow added Length C Factor Notes Elev 1 Fittings& Total(Pt) Node 1 K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (Foot) — (q) Length) Fitting Pf Friction Elev Pe ( ) Fixed Pressure Losses,when Elev 2 Total Flow Equiv. (Foot) Loss Per Unit applicable,are added directly Node 2 Actual ID Length Total (Foot) (Q) (Foot) (psi) Friction(Pf) to(Pf)and shown as a (Foot) negative value. 9 18'-0 3/4 (See 29'-4% 150 28.929 Route 8 Notes) 4'-0 -0.000 0.125202 2Tr(0'-6),E(1'-0),T(2'-0) 7 18'0 12.44 0.8110 33'-43/0 4.181 33.111 Total(Pt) Route 8 14 8'-0 3/a (See 32'-3'/z 150 42.628 Route 9 Notes) 4'-6 0.024000 5Tr(0'6),T(2'-0) 8 8'-0 5.09 0.8110 36'-9'/z 0.883 43.511 Total(Pt) Route 9 &©M.E.P.CAD,Inc. di AutoSPRINK®12 v12.0.48.0 1 6/13/2016 11:28:58AM Page 7 Job Name: Morriss Residence Remote Area Number: 1 Date: 6/13/2016 [Equivalent Pipe Lengths of Valves and Fittings(C=120 only) T—IC Value Multiplier II Actual Inside Diameter 4.87 Value Of C 100 130 140 150 =Factor ( Schedule 40 Steel Pipe Inside Diameter Multiplying Factor 0.713 1.16 1.33 1.51 Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BaIV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DeIV Deluge Valve DPV Dry Pipe Valve E 90°Elbow EE 45°Elbow Eel 11'/4°Elbow Ee2 22'/20 Elbow _ f Flow Device fd Flex Drop FDC Fire Department Connection _ fE 90°FireLock(TM)Elbow fEE 45°FireLock(TM)Elbow flg Flange FN Floating Node fT FireLock(TM)Tee g Gauge GIoV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° I Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap &©M.E.P.CAD,Inc. di AutoSPRINK®12 v12.0.48.0 1 6/13/2016 11:28:58AM Page 8 '"Apo1o#Valves Model DC40 r Made In/an MA DOUBLE CHECK VALVE w w.apollovalves.corn Job Name: Contractor: Job Location: P.O. Number: Engineer: Representative: Tag: Wholesale Distributor: SPECIFICATIONS The Apollo®Model DC40 Double Check Valve assembly shall prevent contamination of the potable water supply due to back-siphonage or backpressure from substances that are ' objectionable, but non-health hazards.The bronze body shall Pi" .14\act .. : -: be configured with individually-accessible top-access check Jib •valves including top-mounted test cocks.The replaceable - i - ji seat rings shall be glass-filled Noryl°and the reversible seat discs shall be silicone rubber. The Apollo°domestic shut-off ball valves shall have stainless steel handles. The pressure DIMENSIONS (in.)-WEIGHTS (lbs.) drop across the assembly shall be documented by USC's FCCC&HR approval curves. Size 3/4" 1" 1 1/4" 1 1/2" 2" A 13 143/4 203/4 213/8 23 % FEATURES B 7 % 71/4 123/8 123/8 12 % • Low pressure loss C 5 1/2 5 % 6 3- /8 6% 6% • Corrosion resistant D 2 7/a 3 % 4 '- /s 4 1/ 4 '/s • Top-mounted test cocks for easy testing Wt. - 8.8 9.5 23.2 25.7 31.5 • Replaceable seats&reversible silicone seat discs • Apollo°ball valves w/SS handles&nuts standard • MADE IN THE USA ,,....'f&140 ��I, ® • 61/11 ISO 9001:2008 ORDERING INFORMATION - REGISTERED ° ° 4 — 1 X X — T X X 2 Alt b •'ii C(REF.) I— /H / L OPTION 0 D. —1-� SHUT-OFF VALVES [- B SIZE f ° – A(REF.) Y-STRAINER Y-STRAINER FLOW CURVES ❑ 0– None (Standard) ❑ 1 –With Y-Strainer ----1. 3/4"-1" SIZE - - '7.5fus 314" 1" ❑ 4-3/4" ❑ 5- 1" ❑ 6- 11/4" 15 ❑ 7- 1 %" ❑ 8-2" y 13 o 11 - 3'0. g -- SHUT-OFF VALVES (Inlet x Outlet) ❑ 1 – Less ball valves (UL Classified) a s/ ------___----- ❑ 2–With Apollo°ball valves 3 ' ' 1 ' CI4–With union-end Apollo°ball valves 0 10 2 30 4o so 60 7o so Flowrate(gpm) OPTIONS —1 114" ❑ F–SAE flare test cock fittings (3/4" & 1"only) ----11/2" ❑ LL–Locking Lever Handles on Apollo° ball valves 11/4 -2" 7.5 Ws 11,4" 11,2. 2.. APPROVALS 14 12 ASSE°1015, CSA°B64.5, IAPMO, USC's FCCC& HR, 10 ; AWWA C-510 and ULA �.n 8 ,_._._- *UL-Classified less ball valves only 6 _ 4 , -. --r--- PERFORMANCE RATING 2 ' 0 20 40 60 80 100 120 140 160 180 200 220 240 Maximum Working Pressure 175 psi Hydrostatic Test Pressure 350 psi Flowrate(gpm) Temperature Range 33 °F– 180 °F Conbraco Industries, Inc.701 Matthews Mint Hill Rd. Matthews NC 28105 USA;www.apollovalves.com;704-841-6000 This specification is provided for reference only.Conbraco reserves the right to change any portion of this specification without notice and without incurring obligation to make such changes to Conbraco products previously or subsequently sold. SS1036 ©3/10 Page 1 of 1 FOR SMALL PIPE VS R-S r PPTTE.RO VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD UL,ULC,CSFM Listed and NYMEAAccepted,CE Marked Service Pressure: Up to 250 PSI (17,2 BAR) Minimum Flow Rate for Alarm: 8-10 GPM(30-38 LPM) Maximum Surge: 18 FPS (5,5 m/s) Enclosure: Die-cast, red enamel finish Cover held in place with tamper resistant screws Contact Ratings: Two sets of SPDT(Form C) 15.0 Amps at 125/250 VAC 2.0 Amps at 30 VDC Conduit Entrances: Two knockouts provided for 1/2"conduit. Usage: Listed plastic, copper and schedule 40 iron pipe. Fits pipe sizes - 1" (25mm), 1 1/4" (32mm), 1 1/2" (38mm) and 2" (50mm) Note: 12 paddles are furnished with each unit, one for each pipe size of threaded and sweat TEE, one for 1" (25mm) CPVC, one for 1" (25mm) CPVC (Central), 4 one for 1 1/2" (38mm) polybutylene and one for 1 1/2" (38mm) threaded (Japan). (CTS-Copper tubing size) Environmental Specifications: • Suitable for indoor or outdoor use with factory installed gasket and die-cast housing. • NEMA 4/IP55 rated enclosure-use with appropriate conduit fitting. • Temperature range: 40° F to 120° F,4,5° C to 49° C) Caution: This device is not intended for applications in explosive environments. Service Use: StoCkNo.1113000 Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D U.S. Pat. No.3921989, Canadian Pat. No. 1009680 Residential occupancy up to four stories NFPA-13R Other Patents Pending National Fire Alarm Code NFPA-72 Optional: Cover Tamper Switch Kit, Stock No. 0090018 The Model VSR-SF is a vane type waterflow switch for use on wet Screw the device into the TEE fitting as shown in Fig. 2. Care sprinkler systems that use 1" (25mm), 1 1/4" (32mm), 1 1/2" must be taken to properly orient the device for the direction of (38mm) or 2" (50mm) pipe size. The unit may also be used as waterflow. a sectional waterflow detector on large systems. The vane must not rub the inside of the TEE or bind in any way. The unit contains two single pole double throw snap action The stem should move freely when operated by hand. switches and an adjustable, instantly recycling pneumatic re- The device can also be used in copper or plastic pipe installa- tard.The switches are actuated when a flow of 8-10 gallons per tions with the proper adapters so that the specified TEE fitting minute (30-38 LPM)or more occurs downstream of the device. may be installed on the pipe run. The flow condition must exist for a period of time necessary to overcome the selected retard period. INSPECTION AND TESTING: Check the operation of the unit by opening the inspector's test valve at the end of the sprinkler line INSTALLATION: These devices may be mounted in horizontal or the drain and test connection,if an inspector's test valve is not or vertical pipe. On horizontal pipe they should be installed on provided. the top side of the pipe where they will be accessible. The units should not be installed within 6"(15cm)of a valve,drain or fitting If there are no provisions for testing the operation of the flow which changes the direction of the waterflow. Select the proper detection device on the system,application of the VSR-SF is not paddle for the pipe size and type of TEE used see Fig. 1 for recommended or advisable instructions on changing paddle. The unit has a 1"NPT bushing The frequency of the inspection and testing and its associated for threading into a non-corrosive TEE. See Fig.2 for proper TEE protective monitoring system should be in accordance with the size, type and installation. Use no more than three wraps of applicable NFPA Codes and Standards and/or authority having teflon tape. jurisdiction (manufacturer recommends quarterly or more fre- quently). Potter Electric Signal Company•2081 Craig Road,St.Louis,MO,63146-4161 •Phone:800-325-3936/Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MKT.#8800003-REV AA PAGE 1 OF 2 MFG.#5400802-11/02 VS`� `��� r le POTTER VANE TYPE WATERFLOW FOR SMALL PIPE The Symbol of Protection ALARM SWITCH WITH RETARD FIG. 1 DO NOT LEAVE COVER FIG. 2 OFF FOR EXTENDED Retard Adjustment: PERIOD OF TIME '44 411 .0 To change time, turn knob - �� (either direction) for desired { � ,%i;; FLOW time delay. Use the minimum WAIl1�� y 1 11/16"APPRox, amount of retard necessary to MOUNT SO • '' (WHITE) COM, (4,3mm) prevent false alarms. A "B" (RED) N,O, / AR BUSHING / (BLACK) N,C, setting is usually adequate for POINTS IN _ DIRECTION OF / this. Factory set at"B". WATERFLOW 1— IIII 1 Shown with optional 1"NPT / r i I 10, THREADED Cover Tamper Switch \ DEPTH / FITTING ON ALL SIZES Kit. DIRECTION OF i %I ti WATER FLOW • RTUE OFT THE OR THREADED E �� SWEAT TYPE J DIREWATER FLOW (((lScrew the device into the tee fitting as shown.Care must be taken to properly orient the device for the direction of waterflow.On sweat tees,no DWG, #737-31 �� threaded bushings,inserts,or adapters are permitted,unless they comply DWG, #802-30 with the dimensions listed in the chart below. Important: Important-The depth to the inside bottom of the tee should have the There are 12 paddles fur- cAuTloNr TO PREVENT LEAKAGE APPLY TEFLON TAPE SEALANT following dimensions: nished with each unit.One for TO MALE THREADS ONLY, DO NOT USE ANY OTHER each size of threaded,sweat or TYPE OF LUBRICANT OR SEALANT, APPROXIMATE DEPTH REQUIREMENT plastic TEE as described in Fig. 2. These paddles have APPROX, RETARD SETTINGS (IN SEC.) TEE SIZE THREADED SWEAT CTS, POLYBUTYLENE CPVC raised lettering that shows the o A B c D E I" x 1" x 1" 2 1/16" 1 3/4" N/A 2 7/16" pipe size and type of TEE that o 10-25 20-40 35-55 50-70 60-90 I 1/4" x 1 1/4" x 1" 2 7/16" 2 7/16" N/A N/A 1 1/2" x 1 1/2" x 1" 2 11/16" 2 1/4" 2 1/2" N/A they are to be used with. The 2" x 2" x1" 3 3/16" 2 3/4" N/A N/A proper paddle must be used. The paddle must be properly DWG. #735-33 attached (see drawing) and Warning: Do not use more than three wraps of teflon tape. the screw that holds the pad- dle must be securely tight- ened. SWITCH TERMINAL CONNECTIONS CLAMPING PLATE TERMINAL FIG. 3 ��� rco010 CAUTION: An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be c� severed, thereby providing supervision of the connection in the event that 0600 DWG.#923-3 the wire becomes dislodged from under the terminal. FIG.4 TYPICAL ELECTRICAL CONNECTIONS FIG. 5 NOTES: To remove knockouts: Place 2 SETS OF NORMALLY OPEN CONTACTS WATERFLOW ZONE EOLR FROM 1. The model VSR-SF has two screwdriver at edge of knock- CLOSE ON ALARM ON FIRE PANEL FIRE PANEL switches,one can be used to outs, not in the center. ¢„� m ,�� operate a central station, M El M IJ ` ' - proprietary or remote signal- 1— = = = ing unit, while the other is 1 C0.� used to operate a local au- M 0 ❑© IETI cdible or visual annunciator. �I M 2. For supervised circuits see THE NC AND NO MARKINGS POSITIVE DC ON THE SWITCH ARE FOR OR HOT AC ® "Switch Terminal Connec- AN ALARM CONDITION, tions" drawingand caution c,< <► NEGATIVE DC t% i--/ THE CONTACTS ARE REVERSED OR NEUTRAL AC 'ci� WHEN THE DEVICE IS IN TwG,#761-2 note(Fig.3). �I o 1gWfr19� THE NORMAL CONDITION. .� DWG.#761-4 APPLICATION WARNING! Due to the possibility of unintended discharges caused by pressure surges, trapped air, or short retard times,waterflow switches that are monitoring wet pipe sprinkler systems should not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. PRINTED IN USA MKT.#8800003-REV AA PAGE 2 OF 2 MFG.#5400802-11/02 TABLE 2c. Dimensions and Physical Characteristics of Copper Tube:TYPE M Nominal Dimensions, inches Calculated Values(based on nominal dimensions) _ Nominal or I Cross Weight Weight I Contents of Tube Standard Outside Inside Wall Sectional of Tube Only, of Tube&Water,' per linear ft Size,inches Diameter Diameter Thickness Area of Bore, pounds pounds Cu ft 1 Gal sq inches per linear ft per linearft 3/8 .500 .450 .025 .159 .145 .214 .00110 .00826 1/2 .625 .569 .028 .254 .204 .314 .00176 .0132 3/4 .875 .811 .032 .517 .328 .551 .00359 .0269 1 1.125 1.055 .035 .874 .465 .843 .00607 .0454 11/4 1.375 1.291 .042 1.31 .682 1.25 .00910 .0681 11/2 1.625 1.527 .049 1.83 .940 1.73 .0127 .0951 2 2.125 2.009 .058 3.17 1.46 2.83 .0220 _ .165 21/2 2.625 2.495 .065 4.89 2.03 4.14 .0340 .254 3 3.125 2.981 .072 6.98 2.68 5.70 .0485 .363 31/2 3.625 3.459 .083 9.40 3.58 7.64 .0653 .488 4 4.125 3.935 .095 12.2 4.66 9.83 .0847 .634 5 5.125 4.907 .109 18.9 6.66 14.8 .131 .982 6 6.125 5.881 .122 27.2 8.92 20.7 .189 1.41 8 8.125 7.785 .170 47.6 16.5 37.1 .331 2.47 10 10.125 9.701 .212 73.9 25.6 57.5 .513 3.84 12 12.125 11.617 .254 106 36.7 82.5 .736 5.51 TABLE 2d. Dimensions and Physical Characteristics of Copper Tube: DWV(Drain, Waste and Vent) Nominal Dimensions,inches Calculated Values(based on nominal dimensions) Nominal or Cross Weight Weight Contents of Tube _ Standard Outside Inside Wall Sectional of Tube Only, of Tube&Water, per linear ft Size,inches Diameter Diameter Thickness Area of Bore, pounds pounds sq inches per linear ft per linear ft Cu ft Gal 11/4 1.375 1.295 .040 1.32 .650 1.22 .00917 .0686 11/2 1.625 1.541 .042 1.87 .809 1.62 .0130 .0971 2 2.125 2.041 .042 3.27 1.07 2.48 .0227 .170 3 3.125 3.030 .045 7.21 1.69 4.81 .0501 .375 4 4.125 4.009 .058 11.6 2.87 7.88 .0806 .603 5 5.125 4.981 .072 19.5 4.43 12.9 .135 1.01 6 6.125 5.959 .083 27.9 6.10 18.2 .194 1.45 8 8.125 7.907 .109 49.1 10.6 31.8 .341 2.55 22 TABLE 3c. Rated Internal Working Pressure for Copper Tube: TYPE M* Annealed*** Drawn** Nominal s= s= s= s= s= s= s= s= s= s= s= s= s= s= Size,in 6000 psi 5100 psi 4900 psi 4800 psi 4700 psi 4000 psi 3000 psi 10,300 psi 10,300 psi 10,300 psi 10,300 psi 10,000 psi 9,700 psi 9,400 psi 100 F 150 F 200 F 250 F 300 F 350 F 400 F 100 F 150 F 200 F 250 F 300 F 350 F 400 F 3/8 570 485 466 456 447 380 285 982 982 982 982 953 925 896 1/2 494 420 403 395 387 329 247 850 850 850 850 825 800 776 3/4 407 346 332 326 319 271 204 701 701 701 701 680 660 639 1 337 286 275 270 264 225 169 580 580 580 580 563 546 529 11/4 338 287 276 271 265 225 169 582 582 582 582 565 548 531 11/2 331 282 270 265 259 221 166 569 569 569 569 553 536 520 2 299 254 244 239 234 199 149 514 514 514 514 499 484 469 21/2 274 233 224 219 215 183 137 471 471 471 471 457 444 430 3 253 215 207 203 199 I 169 127 435 I 435 435 435 423 410 397 1 31/2 252 214 206 202 197 168 126 433 433 433 433 421 408 395 4 251 213 205 201 197 167 126 431 431 431 431 419 406 394 5 233 198 190 186 182 155 116 400 400 400 400 388 377 365 6 218 186 178 175 171 146 109 375 375 375 375 364 353 342 8 229 195 187 183 180 153 115 394 394 394 394 382 371 359 10 230 195 188 184 180 153 115 394 394 394 394 383 371 360 12 230 195 188 184 180 153 115 395 395 395 395 383 372 360 TABLE 3d. Rated Internal Working Pressure for Copper Tube: DWV* Annealed*** Drawn** S= S= S= S= S= S= S= S= S= S= S= S= S= S= Nominal Size,in 6000 psi 5100 psi 4900 psi 4800 psi 4700 psi 4000 psi 13000 psi 10,300 psi 10,300 psi 10,300 psi 10,300 psi 10,000 psi 9,700 psi 19,400 psi 100 F 150 F 200 F 250 F 300 F 350 F 400 F 100 F 150 F 200 F 250 F 300 F 350 F 400 F 11/4 330 280 269 264 258 220 165 566 566 566 566 549 533 516 11/2 293 249 240 235 230 196 147 503 503 503 503 489 474 459 2 217 185 178 174 170 145 109 373 373 373 373 362 352 341 3 159 135 130 127 125 106 80 273 273 273 273 265 257 249 4 150 127 122 120 117 100 75 257 257 257 257 250 242 235 5 151 129 124 121 119 101 76 260 260 260 260 252 245 237 6 148 126 121 119 116 99 74 255 255 255 255 247 240 232 8 146 124 119 117 114 97 73 251 251 251 251 244 236 229 NOTE: *Based on maximum allowable stress in tension (psi)for the indicated temperatures(°F),see page 12. **When brazing or welding is used to join drawn tube,the corresponding annealed rating must be used,see page 12. ***Types M and DWV are not normally available in the annealed temper.Shaded values are provided for guidance when drawn temper tube is brazed or welded,see page 12. 26 TABLE 5. Actual Burst Pressures,'Types K, L, and M Copper Water Tube, psi at Room Temperature Nominal or K 12 M ' The figures shown are averages Standard Size, Actual Outside of three certified tests per- inches Diameter, in Drawn Annealed Drawn Annealed Drawn Annealed formed on each type and size of water tube. In each case, 72 5/8 9840 4535 7765 3885 6135 — wall thickness was at or near 3/4 7/8 9300 4200 5900 2935 4715 — the minimum prescribed for each tube type. No burst 1 11/8 7200 3415 5115 2650 3865 — pressure in any test deviated 8 — from the average by more than 11/4 1 /8 5525 2800 4550 2400 3875 5 percent. 11/2 15/8 5000 2600 4100 2200 3550 — 2 These burst pressures can be used for ACR tube of equivalent 2 21/8 3915 2235 3365 1910 2935 — actual O.D.and wall thickness. 21/2 25/8 3575 — 3215 — 2800 — 3 378 3450 — 2865 — 2665 — 4 41/8 3415 — 2865 — 2215 — 5 578 3585 — 2985 — 2490 — 6 61/8 3425 — 2690 — 2000 — 8 81/8 3635 — 2650 — 2285 — 29 TABLE 6. Pressure Loss of Water Due to Friction in Types K, L and M Copper Tube (psi per linear foot of tube) NOMINAL OR STANDARD SIZE,INCHES FLOW, 1/4 3/8 1/2 3/4 t 1 1/4 1 1/2 2 GPM KLMK L MKL MK L M KL MK L MK L MK L M 1 0.138 0.118 N/A 0.036 0.023 0.021 0.010 0.008 0.007 0.002 0.001 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2 N/A 0.130 0.084 0.075 0.035 0.030 0.024 0.006 0.005 0.004 0.002 0.001 0.003 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 3 N/A 0.275 0.177 0.159 0.074 0.062 0.051 0.014 0.011 0.009 0.003 0.003 0.001 0.001 0.001 0.001 0.000 0.000 0.000 0.000 0.000 0.000 4 N/A 0.125 0.106 0.086 0.023 0.018 0.015 0.006 0.005 0.004 0.002 0.002 0.002 0.001 0.001 0.001 0.000 0.000 0.000 5 N/A 0.189 0.161 0.130 0.035 0.027 0.023 0.009 0.007 0.006 0.003 0.003 0.002 0.001 0.001 0.001 0.000 0.000 0.000 10 N/A 0.126 0.098 0.084 0.031 0.027 0.023 0.010 0.010 0.009 0.004 0.004 0.004 0.001 0.001 0.001 15 N/A 0.065 0.057 0.049 0.022 0.020 0.018 0.009 0.009 0.008 0.002 0.002 0.002 20 N/A 0.096 0.084 0.037 0.035 0.031 0.016 0.015 0.014 0.004 0.004 0.004 25 N/A 0.057 0.052 0.047 0.024 0.022 0.021 0.006 0.006 0.005 30 N/A 0.079 0.073 0.066 0.034 0.031 0.029 0.009 0.008 0.008 35 N/A 0.045 0.042 0.039 0.012 0.011 0.010 40 N/A 0.058 0.054 0.050 0.015 0.014 0.013 45 N/A 0.062 0.018 0.017 0.016 50 N/A 0.022 0.021 0.020 60 N/A 0.031 0.029 0.028 70 N/A 0.042 0.039 0.037 80 N/A 90 N/A 100 N/A 120 N/A 140 N/A 160 N/A 180 N/A 200 N/A 250 N/A 300 N/A 350 N/A 400 N/A 450 N/A 500 N/A 550 N/A 600 N/A 650 N/A 700 N/A 760 N/A 1000 N/A 2000 N/A NOTES: 1.Fluid velocities in excess of 5-8 feet per second are not recommended. 2.Friction loss values shown are for the flow rates that do not exceed a velocity of 8 feet per second. 3. Highlighted and italicized friction loss values indicate flow rates that are between 5 feet and 8 feet per second. 30 NOMINAL OR STANDARD SIZE,INCHES FLOW, 2'/2 3 4 5 6 8 10 12 GPM K LMK L MK L MK L M K L MK L MK L MK L M 1 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 3 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 10 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 15 0.001 0.001 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 20 0.001 0.001 0.001 0.001 0.001 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 25 0.002 0.002 0.002 0.001 0.001 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 30 0.003 0.003 0.003 0.001 0.001 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 35 0.004 0.004 0.004 0.002 0.002 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 40 0.005 0.005 0.005 0.002 0.002 0.002 0.001 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 45 0.006 0.006 0.006 0.003 0.003 0.002 0.001 0.001 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 50 0.008 0.007 0.007 0.003 0.003 0.003 0.001 0.001 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 60 0.011 0.010 0.010 0.005 0.004 0.004 0.001 0.001 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 70 0.014 0.014 0.013 0.006 0.006 0.005 0.002 0.001 0.001 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 80 0.019 0.017 0.016 0.008 0.007 0.007 0.002 0.002 0.002 0.001 0.001 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 90 0.023 0.022 0.020 0.010 0.009 0.009 0.002 0.002 0.002 0.001 0.001 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 100 0.028 0.026 0.025 0.012 0.011 0.010 0.003 0.003 0.003 0.001 0.001 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 120 0.035 0.017 0.016 0.015 0.004 0.004 0.004 0.001 0.001 0.001 0.001 0.001 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 140 0.022 0.021 0.019 0.006 0.005 0.005 0.002 0.002 0.002 0.001 0.001 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 160 0.028 0.026 0.025 0.007 0.007 0.006 0.002 0.002 0.002 0.001 0.001 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 180 0.009 0.008 0.008 0.003 0.003 0.003 0.001 0.001 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 200 0.011 0.010 0.010 0.004 0.003 0.003 0.002 0.001 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 250 0.016 0.015 0.015 0.006 0.005 0.005 0.002 0.002 0.002 0.001 0.001 0.001 0.000 0.000 0.000 0.000 0.000 0.000 300 0.021 0.008 0.007 0.007 0.003 0.003 0.003 0.001 0.001 0.001 0.000 0.000 0.000 0.000 0.000 0.000 350 0.010 0.010 0.009 0.004 0.004 0.004 0.001 0.001 0.001 0.000 0.000 0.000 0.000 0.000 0.000 400 0.013 0.012 0.012 0.006 0.005 0.005 0.001 0.001 0.001 0.000 0.000 0.000 0.000 0.000 0.000 450 0.017 0.015 0.015 0.007 0.006 0.006 0.002 0.002 0.002 0.001 0.001 0.001 0.000 0.000 0.000 500 0.008 0.008 0.008 0.002 0.002 0.002 0.001 0.001 0.001 0.000 0.000 0.000 550 0.010 0.009 0.009 0.003 0.002 0.002 0.001 0.001 0.001 0.000 0.000 0.000 600 0.012 0.011 0.011 0.003 0.003 0.003 0.001 0.001 0.001 0.000 0.000 0.000 650 0.013 0.012 0.004 0.003 0.003 0.001 0.001 0.001 0.001 0.000 0.000 700 0.004 0.004 0.004 0.001 0.001 0.001 0.001 0.001 0.001 760 0.005 0.004 0.004 0.002 0.001 0.001 0.001 0.001 0.001 1000 0.008 0.007 0.007 0.003 0.002 0.002 0.001 0.001 0.001 2000 0.004 0.004 0.004 NOTES: 4.Table 6 is based on the Hazen-Williams formula: P_4.52Q185 C,.85 d4.8] Where: U P=friction loss,psi per linear fool Q=flow,g.p.m. d=average I.D.,in inches C=constant.150 31 TABLE 7. Pressure Loss in Fittings and Valves Expressed as Equivalent Length of Tube, feet Nominal Fittings Valves or Standard Ell 90°Tee Coupling Standard Side Straight Size, in 90° 45° Branch Run Ball Gate Btfly Check 3/8 .5 - 1.5 - - - - - 1.5 1/2 1 .5 2 - - - - - 2 5/2 1.5 .5 2 - - - - - 2.5 3/4 2 .5 3 - - - - - 3 1 2.5 1 4.5 - - .5 4.5 11/4 3 1 5.5 .5 .5 .5 - - 5.5 11/2 4 1.5 7 .5 .5 .5 6.5 2 5.5 2 9 .5 .5 .5 .5 7.5 9 21/2 7 2.5 12 .5 .5 - 1 10 11.5 3 9 3.5 15 1 1 - 1.5 15.5 14.5 31/2 9 3.5 14 1 1 - 2 - 12.5 4 12.5 5 21 1 1 - 2 16 18.5 5 16 6 27 1.5 1.5 - 3 11.5 23.5 6 19 7 34 2 2 - 3.5 13.5 26.5 8 29 11 50 3 3 - 5 12.5 39 NOTES: Allowances are for streamlined soldered fittings and recessed threaded fittings. For threaded fittings,double the allowances shown in the table. The equivalent lengths presented above are based upon a C factor of 150 in the Hazen-Williams friction loss formula.The lengths shown are rounded to the nearest half foot. 32 FIGURE 2. Collapse Pressure of Copper Tube, Types K, L and M Drawn Copper Tube 10000 �a� — ,j —I 9000 •p3—oho_0�,0 Obp—OHO Opp �a O 8000 a � 7000 S� 6000 ,.'s 5000 - 4000 , 3000 2000 _ 'y Q 1000 G1 i y 0 1/2 1 1 1/2 2 2 1/2 3 G1 i et = Annealed Copper Tube H 0 2000 IM ›.' 1900 S 1800 1700 1600 O — 0 0 O O A4 I 1500 030 pp9 Oy6 066 O.�O 09,6 OgO X00 ,�0 1400 1300 1200 1100 1000 900 L\ L m \ 800 700 600 500 — _ 400 __ 300 200 100 0 0 1/2 1 1 1/2 2 2 i/z 3 Nominal or Standard Size, inches 33 FIGURE 3. Expansion vs. Temperature Change for Copper Tube 4.5 0 4.0 U m 3.5 a) U- c' 3.0 a) c 2.5 0 co 2.0 c 0 C—) 1.5 0 1.0 N c c� 0.5 w 0.0 0 25 50 75 100 125 150 175 200 225 250 275 300 325 350 Temperature Change, °F 34 FIGURE 5. Selected Pressure Fittings ADAPTERS r OO iO 2 Inli - ■ FTGxM FTGxF CxC Adapter Adapter Union millikiiiiiii OO © ji 03 Li OO 2 III D i O II I C x M C x F C x C x F Adapter Adapter Tee ELBOWS 2020 OO X20 (CDO �, C x C C x C C x C x C 45° Elbow 90° Elbow Tee 20 (0 1/ IF 02 .O © , ; FTGxC FTGxC CxFTGxC 45°Elbow 90°Elbow Tee COUPLINGS Ii.© iO CxC CxC CxC CxC Roll Stop Staked Stop No Stop Reducing GENERAL NOTES: (a)Fittings are designated by size in the order: 1x2x3(b) Fitting designs and drawings are for illustration only. 36 FIGURE 6. Dimensions of Solder Joint Fitting Ends j T 1 I A F 1 I. K -..- I' G ;I Male End Female End WROUGHT FITTING ENDS' 1 I I ii + 'I-41- K G -°"1 _7-4 Male End Female End CAST FITTING ENDS' Drawings and designs of fittings are for illustration only. TABLE P rlimancinns of Solder Joint Ends for Wrought(W) and Cast(C) Pressure Fittings, inches Nominal Male End _ Female End For use with tube size or Outside Diameter Length Inside Diameter 1 Depth under under under under Standard A K F G ASTM ASTM ASTM ASTM Fittings B 88 B 280 B 819 B 837 Size,In. Type Min. Max. Min. Min. Max. Min. '/e W .248 .251 .38 .252 .256 .31 1/4 * 14 1/4 C W .373 .376 .38 .377 .381 .31 1/4 3/8 1/4 3/8 3/8 C W .497 .501 .44 .502 .506 .38 3/e /2 3/8 1/2 1/2 C W .622 .626 .56 .627 .631 .50 1/2 5/8 1/2 5/8 5/8 W .747 .751 .81 .752 .756 .75 5/8 3/4 5/8 3/4 3/4 C W .872 .876 .81 .877 .881 .75 3/4 7/8 3/4 7/8 1 C W 1.122 1.127 .97 1.128 1.132 .91 1 11/8 1 11/8 11/4 C W 1.372 1.377 1.03 1.378 1.382 .97 11/4 13/8 11/4 11/2 C W 1.621 1.627 1.16 1.628 1.633 1.09 11/2 15/8 11/2 2 C W 2.121 2.127 1.41 2.128 2.133 1.34 2 21/8 2 21/2 C W 2.621 2.627 1.53 2.628 2.633 1.47 21/2 25/8 21/2 3 C W 3.121 3.127 1.72 3.128 3.133 1.66 3 31/8 3 31/2 C W 3.621 3.627 1.97 3.628 3.633 1.91 31/2 35/8 31/2 4 C W 4.121 4.127 2.22 4.128 4.133 2.16 4 41/8 4 5 C W 5.121 5.127 2.72 5.128 5.133 2.66 5 * 5 6 C W 6.121 6.127 3.22 6.128 6.133 3.09 6 * 6 8 C W 8.119 8.127 4.09 8.128 8.133 3.97 8 8 10 C 10.119 10.127 4.12 10.128 10.133 4.00 10 * * 12 C 12.119 12.127 4.62 12.128 12.133 4.50 12 * Copper tube under this standard is not commercially available. 37 Wheatland's Mega-Th read The High Quality Alternative to Schedule 40 Sprinkler Pipe ,,,,iedule 40 strength and dependability. Better hydraulics and value. Engineered to provide greater value and reduced costs in threadable applications. Features and Benefits Specification and Approvals • Wheatland's Mega-Thread offers an inside Wheatland's Mega-Thread is quality diameter which is 3.6% larger than Schedule 40. manufactured to meet or exceed the This results in improved hydraulics and opens following standards: the door to down-sizing when used in conjunction with Wheatland's. • ASTM: A-795 Type E, Grade A • Safer to weld than many zinc-coated lightwall • NFPA 13 threadable products. • UL Listed for wet, dry and • Wheatland's Mega-Thread threads smoothly preaction sprinkler systems. and easily and requires no thread warning. • FM Approved for use in wet • The proprietary mill coating on Wheatland's systems. Mega-Thread extends shelf-life and eases paint • Hot-dipped galvanized Mega- application. Thread meets FM requirements • Offering increased strength and light weight, for dry systems. Wheatland's Mega-Thread helps reduce • Rated 300 psi working pressure. installation fatigue. • Approved for standard hanger spacing, Approved for all threaded couplings and welded Wheatland's Mega-Thread can be used as outlets and is suitable for all roll-grooved and earthquake sway bracing. plain-end fittings. • More widely accepted than lightwall threadable Specifications and descriptions are accurate as where Schedule 40 is specified. known at time of publication and are subject to change without notice. Specifications Nominal Inside UL CRR* Wheatland's Diameter Mega-Thread NPS Nominal O.D. Mega Sch. 40 Mega Sch. 40 L.W.T. Pipe Nom. Pcs/Lift Thread Thread Wt./Ft. 1 1.315 1.087 1.049 .83 1.00 .61 1.462 70 1 1/4 1.660 1.416 1.380 .91 1.00 .39 1.989 51 1 1/2 1.900 1.650 1.610 .86 1.00 .31 2.370 44 2 2.375 2.117 2.067 .87 1.00 .25 3.094 30 Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY *The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Schedule 40 steel pipe is used as the benchmark (value of 1.0). 1w4; \ Wheatland Tube Company tlu� 900 Haddon Avenue, Collingswood, NJ 08108-2162 Ph 800.257.8182 Fax 856.854.0616 www.wheatland.com 0705 1.0M rev SII CAST IRON IIS Cast Iron Threaded Fittings Class 125 (Standard) FIGURE 351 Size A B Unit Weight 90° Elbow Black NPS DN in mm in mm lbs kg 1/4 8 1/2 13 13/16 22 0.16 0.07 3/6 10 9/16 14 15/16 24 0.25 0.11 ;! 1/2 15 11/16 17 11/8 29 0.40 0.18 3/4 20 13/16 22 115/16 33 0.60 0.27 -. - 1 25 15/16 24 11/2 38 0.92 0.42 11/4 32 11/8 29 13/4 44 1.44 0.65 i--B 11/2 40 15/16 33 115/16 49 1.95 0.88 2 50 19/16 40 21/4 57 3.13 1.42 r 21/2 65 113/16 47 211/16 68 4.94 2.24 B IA 3 80 23/16 56 31/8 79 7.21 3.27 1 31/2 90 27/16 62 37/16 87 9.67 4.39 4 100 211/16 68 313/16 98 12.17 5.52 5 125 35/16 84 41/2 114 21.46 9.73 6 150 3'/e 98 51/e 130 31.33 14.21 8 200 53/16 132 69/16 167 64.56 29.28 FIGURE 371 Unit Weight 90° Elbow, Size A B Black Flange&Screw NPS DN in mm in mm lbs kg 21/2 65 113/6 47 211/6 68 10.22 4.63 -4-AH I 3 80 23A6 56 31/8 79 13.25 6.01 4 100 211A6 68 313/,6 98 21.56 9.78 B ' 6 150 3'/s 98 51/8 130 40.50 18.37 tNominal Pipe Sizes of 4"(100 DN)and larger have two holes tapped for stud or tap bolts. Note:See page 37 for pressure-temperature ratings. 38 www.anvilintl.com AIIVIL PF-9.09 SII CAST IRON IIS Cast Iron Threaded Fittings 0 Class 125 (Standard) R N R FIGURE 356 (Straight) Size A B Unit Weight FIGURE 356R (Reducing) Black 45° Elbow NPS DN in mm in mm lbs kg c 0 1/4 8 7/16 11 3/4 19 0.16 0.07 - y i V 3/8 10 7/16 11 13/16 22 0.23 0.10 ' ,-- 1/2 15 '/,s 11 7/8 22 0.37 0.17 N ,.5' 0) ` co 3/4 20 1/2 13 1 25 0.55 0.25 N "-�- E L .'. 1 25 9/,e 14 11/8 29 0.83 0.38 "' FIGURE 356(Straight) 11/4 32 5/8 16 11/4 32 1.33 0.60 " 11/2 40 13/16 22 17/16 37 1.79 0.81 Q a ti .. ZU 2 50 1 25 111/16 43 2.89 1.31 a ST 21/2 65 11/16 27 1"/16 49 4.29 1.95 2 - 3 80 13/is 30 23/is 56 6.44 2.92 Figure 356R(Reducing) on 31/2 90 13/6 35 23/6 60 8.42 3.82 LL it 4 100 19/1s 40 25/8 67 10.64 4.83 A 6 150 23/16 56 37/16 87 26.02 11.80 9 8 200 27/8 73 41/4 108 50.17 22.75 . mlil Unit Weight A Size A B C D B Black 1 � N 1 NPS DN in mm in mm in mm in mm lbs kg R 1 x 1/2 25 x 15 1/2 15 7/8 22 11/16 27 15/is 33 0.95 0.43 U rz FIGURE 356A Size A B Unit Weight U 221/2° Elbow Black o NPS DN in mm in mm lbs kg L 3/a 20 3/8 10 7322 0.52 0.24 u, 1 25 7/,6 11 125 0.80 0.36 m 4 ` _ 11/4 32 1/2 13 11/8 29 1.40 0.63 .R E 11/2 40 5/8 16 11/4 32 1.64 0.74 8 A B J2 50 3/4 19 17/18 37 2.50 1.13 t J_ i U 21/2 65 3/4 19 15/8 41 3.95 1.79 Note:See page 37 for pressure-temperature ratings. (7) NVIL www.anvilintl.com 39 ,�rEa�aT,o�a PF-11.10 II CAST IRON Cast Iron Threaded Fittings Class 125 (Standard) FIGURE 383 Size Unit Weight Hex Bushing Black Galv. NPS DN Hex All Cast Iron NPS DN lbs kg lbs kg C 1/4 8 0.47 0.21 0.47 0.21 • C 3/8 10 0.47 0.21 0.47 0.21 11/2 40 • C 1/2 15 0.42 0.19 0.42 0.19 -. - - • C 3/4 20 0.47 0.21 0.47 0.21 C 1 25 0.50 0.23 0.50 0.23 C 1/4 8 0.75 0.34 0.75 0.34 C 3/e 10 0.75 0.34 0.75 0.34 • C 1/2 15 0.70 0.32 0.70 0.32 2 50 • C 3/4 20 0.71 0.32 0.71 0.32 • C 1 25 0.73 0.33 0.73 0.33 • C 11/4 32 0.81 0.37 0.81 0.37 • C 1/2 15 1.28 0.58 1.28 0.58 • C 3/4 20 1.25 0.57 1.25 0.57 21/2 65 • C 1 25 1.16 0.53 1.16 0.53 • C 11/4 32 1.24 0.56 1.24 0.56 • C 11/2 40 1.29 0.59 1.29 0.59 • C 1/2 15 1.93 0.88 1.93 0.88 • C 3/4 20 1.92 0.87 1.92 0.87 • C 1 25 1.90 0.86 1.90 0.86 3 80 • C 11/4 32 1.77 0.80 1.77 0.80 • C 11/2 40 1.79 0.81 1.79 0.81 C 2 50 1.90 0.86 1.90 0.86 C 21/2 65 1.63 0.74 1.63 0.74 • C 1 25 2.42 1.10 2.42 1.10 • C 11/4 32 2.56 1.16 2.56 1.16 • C 11/2 40 2.65 1.20 2.65 1.20 31/2 80 - • C 2 50 2.54 1.15 2.54 1.15 • Inside hex C 21/2 65 3.23 1.46 3.23 1.46 See page 35(Malleable Iron) for other available sizes. C 3 80 1.96 0.89 1.96 0.89 Continued on next page. According to specifications,hex bushings and cored plugs should be used with 150#malleable iron and 125#cast iron.Solid plugs and face bushings are recommended for use with 250#and 300#fittings. Note:See page 37 for pressure-temperature ratings. 50 www.anvilintl.com ANVIL PF-9.09 II CAST IRON 11 Cast Iron Threaded Fittings 0 Class 125 (Standard) R N 2' Continued from previous page. FIGURE 383 Size Unit Weight Hex Bushing Black Galv. NPS DN Hex All Cast Iron NPS DN lbs kg lbs kg H • C 1 25 3.59 1.63 3.59 1.63 3 • C 11/4 32 3.54 1.61 3.54 1.61 • C 11/2 40 3.44 1.56 3.44 1.56 - - 4 100 • C 2 50 3.11 1.41 3.11 1.41 13. • C 21/2 65 3.29 1.49 3.29 1.49 r U, C 3 80 3.15 1.43 3.15 1.43 C 31/2 90 2.50 1.13 2.50 1.13 • C 2 50 5.12 2.32 5.12 2.32 *a VJ C N • C 21/2 65 4.87 2.214.87 2.21 Q o U 5 125 • C 3 80 4.83 2.19 4.83 2.19 Q C 31/2 90 4.00 1.81 - - C 4 100 3.94 1.79 3.94 1.79 2 • C 2 50 8.00 3.63 8.00 3.63 N ces • C 21/2 65 7.72 3.50 - - 1v y 6 150 • C 3 80 7.75 3.51 7.75 3.51 L.'2 2 g LE • C 4 100 6.83 3.10 6.83 3.10 C 5 125 5.24 2.38 5.24 2.38 • C 3 80 15.50 7.03 - 42 - • C 4 100 13.93 6.32 - - a 8 200 • C 5 125 13.65 6.19 - - C 6 150 13.19 5.98 13.19 5.98 • Inside hex • C 6 150 24.50 11.11 See page 35(Malleable Iron) 10 250 - for other available sizes. C 8 200 22.00 9.98 - - U FIGURE 385 Size Unit Weight Face Bushing Black o NPS DN NPS DN lbs kg t - 41 3 80 2 50 13.30 6.03 m - 21/2 65 2.55 1.16 = -:- - 4 100E See page 35(Malleable Iron) 3 80 19.20 8.71 for other available sizes. = C) R U According to specifications,hex bushings and cored plugs should be used with 150#malleable iron and 125#cast iron.Solid plugs and face bushings are recommended for use with 250#and 300#fittings. Note:See page 37 for pressure-temperature ratings. (7) iVkL www.anvilintl.com 51 PF-9.09 II CAST IRON 11 Cast Iron Threaded Fittings Class 125 (Standard) FIGURE 387 Size Unit Weight FIGURE 388 Size Unit Weight Square Head Plugs, Black GaIv. Square Head Plugs, Black GaIv. _ Cored NPS DN lbs kg lbs kg Solid NPS DN lbs kg lbs kg 3/4 20 0.13 0.06 0.13 0.06 1/2 15 0.10 0.05 0.10 0.05 1 25 0.25 0.11 0.25 0.113/4 20 0.17 0.08 0.17 0.08 11/4 32 0.39 0.18 0.39 0.18 al 1 25 0.32 0.15 0.32 0.15 ~ " 11/2 40 0.50 0.23 0.50 0.23 11/4 32 0.53 0.24 0.53 0.24 l'- 2 50 0.82 0.37 0.82 0.37 11/2 40 0.76 0.34 0.76 0.34 21/2 65 1.32 0.60 1.32 0.60 2 50 1.23 0.56 11.23 0.56 3 80 1.87 0.85 1.87 0.85 21/2 65 2.00 0.91 2.00 0.91 31/2 90 2.50 1.13 2.50 1.13 3 80 3.18 1.44 3.18 1.44 4 100 4.00 1.81 4.00 1.81 31/2 90 4.38 1.99 - - FIGURE 389 Size Unit Weight FIGURE 380 Size Unit Weight Bar Plugs, Black Galv. Bar Plugs, Black Cored NPS DN lbs kg lbs kg Solid NPS DN lbs kg 4 100 3.82 1.73 3.82 1.73 4 100 5.68 2.58 5 125 6.50 2.95 6.50 2.95 • 5 125 9.60 4.35 6 150 9.94 4.51 9.94 4.51 8 200 20.26 9.19 20.26 9.19 6 150 14.78 6.70 FIGURE 390 Size Unit Weight FIGURE 381 Size Unit Weight Countersunk Plugs Black Galv. Cap Black Galv. NPS DN lbs kg lbs kg NPS DN lbs kg lbs kg 1 25 0.20 0.09 0.20 0.09 a 21/2 65 2.55 1.16 - - 1 /4 32 0.32 0.15 0.32 0.15 3 80 4.10 1.86 - - f :, 11/2 40 0.47 0.21 0.47 0.21 2 50 0.84 0.38 0.84 0.38 4 100 6.40 2.90 - - 21/2 65 1.40 0.63 - - 1 5 125 10.70 4.85 - - 3 80 2.25 1.02 - - 6 150 14.20 6.44 14.20 6.44 31/2 90 3.02 1.37 - - See page 32(Malleable Iron) 4 100 3.76 1.71 8 200 27.23 12.35 27.23 12.35 for other available sizes. - - According to specifications,hex bushings and cored plugs should be used with 150#malleable iron and 125#cast iron.Solid plugs and face bushings are recommended for use with 250#and 300#fittings. Note:See page 37 for pressure-temperature ratings. 52 www.anvilintl.com ANVIL PF-9.09 SII CAST IRON IIS Cast Iron Threaded Fittings Class 125 (Standard) R N rz m FIGURE 370 Minimum Dimensions Unit Weight Locknut Size A B C D Black NPS DN in mm in mm in mm in mm lbs kg c 0 21/2 65 3.500 89 3.180 81 .590 15 0.90 2 1.13 0.51 - N C:11101 F V 3 80 4.270 108 3.840 98 .670 17 0.90 2 1.60 0.73 For nominal sizes smaller than 21/2"(65 DN) 4 100 5.380 137 5.000 127 .800 20 .130 3 1.10 0.50 see Malleable Iron page 27. a� a) tim c Cast Iron Threaded Fittings Eu- Class 250 (Extra Heavy) FIGURE 421 Unit Weight _ 2 90° Elbow Size A B Black z8 NPS DN in mm in mm lbs kg o-o- aa 1/4 8 5/8 16 15/16 24 0.37 0.17 1/2 15 13/16 22 11/4 32 0.75 0.34 3/4 20 15/16 24 17/16 37 1.13 0.51 tip 1 25 11/16 27 15/8 41 1.79 0.81 0= LLLE 11/4 32 15/16 33 115/16 49 3.00 1.36 LL '`- B-'1 11/2 40 11/2 38 21/a 54 4.05 1.84 t i A 2 50 113/16 47 21/2 64 6.76 3.07 c B A 1 21/2 65 2 51 215/16 75 10.56 4.79 a ' 3 80 23/8 60 33/8 86 15.25 6.92 FIGURE 424Size B Unit Weight 45° Elbow Black NPS DN in mm in mm lbs kg 1/2 15 a/16 14 1 25 0.66 0.30 3/4 20 5/8 16 11/e 29 1.04 0.47 0 2 1 25 3/4 19 15/16 33 1.56 0.71 t IP 11/4 32 7/8 22 11/2 38 2.70 1.22 m .� 11/240 11/16 27 111/,6 43 3.55 1.61 E A 5 0 A \' 2 50 15/16 33 2 51 6.07 2.75 Y ) i_iiiiiiinii 21/2 65 15/16 33 21/4 57 9.79 4.44 Note:See page 37 for pressure-temperature ratings. (7) NVIL www.anvilintl.com 53 ,�rEa�aT,o�a PF-9.09 II CAST IRON Cast Iron Threaded Fittings Class 250 (Extra Heavy) FIGURE 425Size A Unit Weight Tee Black NPS DN in mm in mm lbs kg 1/4 8 5/8 16 15/16 24 0.47 0.21 �` _. .,, 3/8 10 "/is 17 11/16 27 0.70 0.32 J r • 1 /2 15 3/4 19 11/4 32 1.20 0.54 3/4 20 7/8 22 17/16 37 1.57 0.71 1 25 1 25 15/8 41 2.43 1.10 11/4 32 13/16 30 115/16 49 3.94 1.79 1-4-B -B-- 11/2 40 1716 37 2'/s 54 5.31 2.41 f A 'FA 2 50 13/4 44 21/2 64 9.01 4.09 ---- - ----r-- 21/2 65 115/16 49 215/16 75 14.23 6.45 A i B 3 80 25/16 59 33/8 86 20.95 9.50 1; 4 100 215/16 75 41/8 105 33.98 15.41 FIGURE 426 Unit Weight Reducing Tee Size A,B C D,E F Black NPS DN NPS DN NPS DN in mm 1 in mm in mm in mm lbs kg 3/4 20 3/4 20 1/2 15 3/4 19 7/8 22 15/16 33 13/8 35 1.37 0.62 1/2 15 3/4 19 1 25 13/8 35 11/2 38 2.03 0.92 ' 1 25 1 25 3/4 20 7/8 22 1 25 11/2 38 19/16 40 2.19 0.99 • 3/4 20 15/16 24 11/8 29 15/8 41 111/16 43 3.21 1.46 11/4 32 11/4 32 1 25 11/16 27 13/16 30 13/4 44 113/16 47 3.49 1.58 - 3/4 20 1 25 11/4 32 111/16 43 17/8 48 4.02 1.82 11/2 40 11/2 40 1 25 11/8 29 15/16 33 113/16 47 11516 49 4.26 1.93 1-,-D-.1`-E 11/4 32 1516 33 13/8 35 2 51 21/16 52 4.98 2.26 AB 3/4 20 11/8 29 17/1e 37 17/8 48 2 51 6.24 2.83 r-- C F 2 50 2 50 1 25 11/4 32 11/2 38 2 51 21/8 54 6.57 2.98 11/4 32 13/8 35 191e 40 2316 56 21/4 57 7.11 3.22 11/2 40 11/2 38 15/8 41 2516 59 25/16 59 7.69 3.49 Note:See page 37 for pressure-temperature ratings. 54 www.anvilintl.com ANVIL PF-9.09 UNITED BRASS WORKS, INC. III 11:11 II OaIt° 714 S. Main St., Randleman, NC 27317 Tel: 800-334-3035 Fax: 800-498-4696 www.ubw.com 1S09001 REGISTERED COMPANY Model 99 Swing Check Valve 1 ilif 125 WSP @ 350° Max ... � � - 200 WOG '{•. ': 100% Pressure Tested 1 - •:_:. f�.''. Tti. .� Threaded Ends • Metal Disc I Ei a Integral Seat !:.it 11.3 1 til Do not install laying on side. Keep seat clean. Not Recommended for Pulsating or Vibrating Service! O � . friti A MATERIAL LIST • � i p NO. DESCRIPTION MATERIAL / 4 1 q r 3 Cap(V 1") Brass „ / Cap(11/4”—2") Bronze 2 Washer Brass 3 Body Bronze i 4 4 Disc Brass 5 Hinge Stainless Steel ',�� / /// / ///,-/, 7-/,W , 0 A -I Size '/4" 3/8" '/z" 3/4" 1" 1 1/4" 1 ,/z" 2" A 1.89 1.89 2.14 2.51 3.03 3.45 3.81 4.44 B 1.22 1.22 1.28 1.53 2.06 2.20 2.20 2.86 Ship Wgt. (lbs.) 0.45 0.45 0.58 0.81 1.62 1.81 2.41 3.42 • Qty.Unit Pack 12 12 12 12 6 6 4 2 Qty.Per Case 60 60 60 60 30 18 12 6 011° UNITED BRASS WORKS, INC. III 11 714 S. Main St., Randleman, NC 27317 1509001 Tel: 800-334-3035 Fax: 800-498-4696 www.ubw.com REGISTERED COMRIFMY Model 125SUL Globe Valve • . -, Soft Disc .1 • c L usUL Listed for Fire Sprinkler Service at 250 WOG • 200 WOG @ 180 ° Max 100% Pressure Tested r i� Threaded Ends • Integral Seat 1 Rising Stem Swivel Disc Holder Irma B O Ii MATERIAL LIST o NO. DESCRIPTION MATERIAL 1 Hex Nut SteelC v (D 2 1 Hand Wheel Aluminum -r N/ //: Il 3 Packing Nut Brass �� j 1 �//' 6 4 Packing Graphite Non-Asb. �m�c.� aaa� O Bonnet('/2" — 1") Brass P/ 5 / Bonnet(1'/4" 2") Bronze 6 Stem&Disc Assm. Brass i / d 7 Disc Buna N �� A 8 Body Bronze Size '/2" 3/4„ 1" 1 1/4„ 1 '/2„ 2" A 2.22 2.47 2.97 3.56 4.06 4.69 B 2.03 2.38 2.75 3.00 3.72 3.72 C(closed) 3.38 3.50 4.25 4.75 5.50 5.50 Ship Wt. (lbs.) 0.69 0.94 1.76 2.50 3.26 5.32 Qty.Unit Pack I 12 6 6 4 2 2 Qty.Per Case 72 60 36 24 12 12 III UNITED BRASS WORKS, INC. 111! i pi I t t 9 714 S. Main St., Randleman, NC 27317 1S09001 Tel: 800-334-3035 Fax: 800-498-4696 www.ubw.com REGISTERED COMPANY Model 80 Ball Valve Double Female (Complies with MSS-SP110-92) 200 lbs. WSP @ 406 ° Max 400 lbs. WOG * 100% Pressure Tested Threaded Ends * Blowout Proof Stem 1/4" - %" Full Flow 3/4" - 2" Large Port Diameters F 0 © MATERIAL LIST E=n 0 NO. DESCRIPTION MATERIAL 'mm 1 Lever Plated Steel w/vinyl grip ''k Y ,- O5 E 2 Stem Brass $d, 3 Jam Nut Plated Steel ®, ��►i%!i 0 4 Packing Nut Brass It �� ��!!!i!ii!!!!� 5 Packing Sleeve Brass IIIIIIIII1I A 0 6 Packing Graphite Non-Asb. 7 Bevel Washer Steel % /. ;„ `��1 8 0-Ring Buna 0 9 Tail Piece(1/4"- 1/2") Brass 40 / Tail Piece(3/4"-2") Bronze 0 10 Body Bronze 10 11 Ball Chrome Plated Brass C D 12 Nest PTFE - 8 SHIP QUAN. SIZE A B C D E F WT.(lbs.) PER CTN. 1/4" 0.38 1.86 0.92 0.94 1.58 3.31 0.52 12 3/8" 0.38 1.86 0.92 0.94 1.58 3.31 0.52 12 '/�" 0.50 2.17 1.06 1.11 2.28 4.23 0.78 12 3/4" 0.63 2.05 1.20 1.31 2.38 4.23 0.98 12 1" 0.81 3 .27 1.67 1.59 2.55 4.23 1.59 6 11/4" 1.00 3.48 1.72 1.77 3.19 5.47 2.47 4 11/2" 1.25 3.97 1.95 2.02 3.38 5.47 3.50 4 2" 1.50 4.41 2.14 2.27 3.56 5.47 5.00 2 2 Page 1 of 6 ® FREEDOM® RESIDENTIAL TECHNICAL DATA CONCEALED PENDENT SPRINKLER VK457 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION - 6 - Viking Freedom° Residential Concealed Pendent Sprinkler VK457 is a small high-sensitivity solder link and lever residential sprinkler designed for installation ',_. - . - _• on concealed pipe systems where the appearance of a smooth ceiling is desired. - _':' - �. ;'� The orifice design, with a K-Factor of 4.9 (70.6 metric*), allows the sprinkler's ef- r ' - :. ficient use of available water supplies for the hydraulically designed fire-protection system.The operating element and special deflector characteristics meet the chal- lenges of residential sprinkler standards. The sprinkler is pre-assembled with a threaded adapter for installation with a low- profile small-diameter cover assembly installed flush to the ceiling. The two-piece design allows installation and testing of the sprinkler prior to installation of the - '{ cover plate. The "push-on", "thread-off' design of the concealed cover plate as- sembly allows easy installation of the cover plate after the system has been tested ' ;,F and the ceiling finish has been applied,while also providing up to 1/2" (12.7 mm)of —^p" vertical adjustment.The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE(ENT)coating has been investigated for installation in corrosive atmospheres and is C-UL-US-EU Listed as corrosion resistant as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. 2. LISTINGS AND APPROVALS c 4L us UL Listed (C-UL-US-EU): Category VKKW EU Refer to the Approval Charts and Design Criteria on for C-UL-US-EU Listing requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 2008. Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 4.9 U.S. (70.6 metric*) *Metric K-factor measurement shown is in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-C51000 Viking Technical Data may be found on Deflector Pins: Stainless Steel UNS-S30200 Button: Brass UNS-C36000 The Viking Corporation's Web site at Seat Assembly: Brass UNS-C31600 http://www.vikinggroupinc.com. Compression Screw: Brass UNS-C36000 The Web site may include a more recent Fusible Element Assembly: Beryllium Nickel, coated with black acrylic paint edition of this Technical Data Page. Levers: Stainless Steel UNS-S31600 Lever Bar: Copper Alloy UNS-C72500 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Shipping Cap: Polyethylene Cover Plate Materials: Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800 Spring: Beryllium Nickel Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Freedom° Residential Concealed Pendent Sprinkler VK457 and Cover Plate Assembly must be ordered separately: Sprinkler: Order Sprinkler VK457 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass =A and ENT= JN Temperature Suffix: 165 °F (74 °C) = C, 205 °F (96 °C) = E For example, sprinkler VK457 with a Brass finish and a 165 °F (74 °C)temperature rating = Part No. 14694AC. Form No. F_072607 Rev 15.1 (Added 205 Temp and Footnote 3 in Table 1) Page 2 of 6 ® FREEDOM® RESIDENTIAL TECHNICAL DATA CONCEALED PENDENT SPRINKLER VK457 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Cover Plate Assembly: Base Part No. 13504 (2-3/4"diameter), Base Part No. 13642 (3-5/16"diameter), or Base Part No. 15394 (square cover plate, 3-5/16" diameter) Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix:Polished Chrome=F, Brushed Chrome=F-/B, Bright Brass=B,Antique Brass=B-/A, Brushed Brass=B-/B, Brushed Copper= E-/B, Painted White = M-/W, Painted Ivory= M-/I, Painted Black= M-/B Temperature Suffix: 135°F/57°C=A For example, cover 13504 with a Polished Chrome finish and a 135 °F/57 °C temperature rating = 13504FA. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the"Sprinkler Accessories"section of the Viking data book.) Sprinkler Wrenches**: A. Heavy Duty Part No. 13623W/B (available since 2006), or B. Head Cabinet Wrench Part No. 13619*** (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part No. 14412 (available since 2007) D. Optional Large Concealed Cover Plate Installer Tool Part No. 14867 (available since 2007) **Requires a''/z'ratchet(not available from Viking).***Also optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature,the cover plate detaches, releasing the deflector. Continued heating of the exposed sprinkler causes the fusible element to disengage releasing the sealing assembly. Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern over a specific area of coverage determined by the water supply pressure at the sprinkler to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinkler Model VK457 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1:AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Sprinkler Nominal Maximum Temperature Rating Cover Plate Large Cover Square Cover Temperature Temperature Ambient Ceiling of the Cover Base Part Plate Base Plate Base Classification Rating' Temperature2 Assembly(Required)3 Number4 Part Number4 Part Number4 Ordinary 165 °F (74 °C) 100 °F (38 °C) 135 °F (57 °C) 13504 13642 15394 Intermediate 205 °F (96 °C) 150 °F (38 °C) 135 °F (57 °C) 13504 13642 15394 Sprinkler Finishes: Brass and ENT Cover Plate Finishes: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Corrosion Resistant Coatings5: ENT Footnotes 'The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction.Refer to specific installation standards. 3 Maximum ambient temperature for cover assembly is 100°F(38°C). 4 Part number shown is the base part number.For complete part number,refer to current Viking price list schedule. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts.These tests cannot and do not represent all possible corrosive environments.Prior to installation,verify through the end-user that the coatings are compatible with or suitable for the proposed environment.For automatic sprinklers,the ENT coating is applied to all exposed exterior surfaces,including the waterway.For ENT coated sprinklers,the Belleville spring is exposed. Form No. F_072607 Rev 15.1 Page 3 of 6 N1KING® FREEDOM® RESIDENTIAL TECHNICAL DATA CONCEALED PENDENT SPRINKLER VK457 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart 1 Viking VK457, 4.9 K-Factor Residential Concealed Pendent Sprinkler or systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria. For Ceiling types refer to NFPA 13, 13R or 13D 2013 Editions Sprink- NPT Thread Size Nominal K-Factor ler Base SIN Maximum Water Working Part Number' Inches mm U.S. metric 2 Pressure 14694AC- (165 °F/74°C) VK457 1/2 15 4.9 70.6 175 psi (12 bar) 14694AE- (205 °F/96°C) Max. Covera- Ordinary Temp Ra- Intermediate Temp s Listings and Approvals ge Area 6 ting (165°F/74°C) Rating (205°F/96°C) Minimum Deflec- Width X Installati- Spacing Length Flow 6 Pressure 6 Flow 6 Pressure6 tor to on Type 4 Ft. Ft.X Ft. GPM PSI GPM PSI Ceiling Oos NYC NSF 8 (m) (m X m) (L/min) (bar) (L/min) (bar) EU 12 X 12 13 7.0 13 7.0 (3.7 X 3.7) (49.2) (0.48) (49.2) (0.48) 14X14 13 7.0 14 8.1 (4.3 X 4.3) (49.2) (0.48) (53) (0.56) Conce- See See 16 X 16 13 7.0 14 8.1 Refer to aled with Foot- See Foot- 8 (4.9 X 4.9) (49.2) (0.48) (53) (0.56) Figure 2 Cover note 7 Foot note 7 Plate As- and 10 note 5 and 10 (2.4) 18 X 18 17 12.0 17 12.0 sembly (5.5 X 5.5) (64.4) (0.83) (64.4) (0.83) 20 X 20 20 16.7 22 20.2 (6.1 X 6.1) (75.7) (1.15) (83.3) (1.39) Footnotes 1 Part number shown is the base part number. For complete part number,refer to current Viking price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 3 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approv- als. Refer also to Design Criteria. 4 Listed by Underwriter's Laboratories,Inc.for use in the U.S.,Canada,and European Union. 5 Meets New York City requirements,effective July 1,2008. 6 For areas of coverage smaller than shown,use the"Flow"and"Pressure"for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum"Flow"and"Pressure"used. 7 Cover Temperature Rating is 135°F(57°C). Cover Part No. 13504',13642'(large diameter),or 15394'(square cover plate). 8 UL Classified to:NSF/ANSI Standard 61,Drinking Water System Components(MH48034). 9 Other paint colors are available on request with the same listings as the standard finish colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3. 10 Accepted Cover Plate Finishes are:Polished Chrome,Brushed Chrome,Bright Brass,Antique Brass,Brushed Brass,Brushed Copper,Painted White,Painted Ivory,or Painted Black 9. Form No. F_072607 Rev 15.1 Page 4 of 6 NIKING1(1 ® FREEDOM® RESIDENTIAL TECHNICAL DATA CONCEALED PENDENT SPRINKLER VK457 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart 2 Viking VK457, 4.9 K-Factor Residential Concealed Pendent Sprinkler For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13,refer to the design criteria. For Ceiling types refer to NFPA 13, 13R or 13D 2013 Editions Sprinkler Base SIN NPT Thread Size Nominal K-Factor Maximum Water Wor- Part Number' Inches mm U.S. metric 2 king Pressure 14694JNC- (165 °F/74 °C) VK457 1/2 15 4.9 70.6 175 psi (12 bar) 14694JNE- (205 °F/96 °C) Max. Coverage Ordinary Temp Rating Intermediate Temp Listings and Appro- Area 5 (165°F/74°C) Rating (205°F/96°C) vals3 Minimum Deflector Installati- SpacingWidth X Length Flow s Pressure 5Flow s Pressure 6 to Ceiling on Type C-UL- Ft. Ft.X Ft. GPM PSI GPM PSIUS-EU a NYC NSF (m) (m X m) (L/min) (bar) (L/min) (bar) 12X12 13 7.0 13 7.0 (3.7 X 3.7) (49.2) (0.48) (49.2) (0.48) 14 X 14 13 7.0 14 8.1 (4.3 X 4.3) (49.2) (0.48) (53) (0.56) Conce- See aled with Foot- 16 X 16 13 7.0 14 8.1 Refer to -- 8 (4.9 X 4.9) (49.2) (0.48) (53) (0.56) Figure 2 Cover notes 6, (2.4) Plate As- 8, and 9 18 X 18 17 12.0 17 12.0 sembly (5.5 X 5.5) (64.4) (0.83) (64.4) (0.83) 20 X 20 20 16.7 22 20.2 (6.1 X 6.1) (75.7) (1.15) (83.3) (1.39) Footnotes 1 Part number shown is the base part number. For complete part number,refer to current Viking price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 3 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approv- als. Refer also to Design Criteria. 4 Listed by Underwriter's Laboratories,Inc.for use in the U.S.and Canada. 5 For areas of coverage smaller than shown,use the"Flow"and"Pressure"for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum"Flow"and"Pressure"used. 6 Cover Temperature Rating is 135°F(57°C). Cover Part No.135041,136421(large diameter),or 153941(square cover plate). 7 Other paint colors are available on request with the same listings as the standard finish colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3. 8 Accepted Cover Plate Finishes are:Polished Chrome,Brushed Chrome,Bright Brass,Antique Brass,Brushed Brass,Brushed Copper, Painted White,Painted Ivory,or Painted Black 7. 9 C-UL-US-EU Listed as corrosion resistant. Form No. F_072607 Rev 15.1 Page 5 of 6 ® FREEDOM® RESIDENTIAL TECHNICAL DATA CONCEALED PENDENT SPRINKLER VK457 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com DESIGN CRITERIA (Also refer to the Approval Chart on page 4.) UL Listing Requirements(C-UL-US-EU): When using Viking Residential Concealed Pendent Sprinkler VK457 for systems designed to NFPA 13D or NFPA 13R,apply the listed areas of cover- age and minimum water supply requirements shown in the Approval Charts. For systems designed to NFPA 13:The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers.The minimum required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates given in the Approval Charts for NFPA 13D and NFPA 13R applications for each listed area of coverage,or • Calculated based on a minimum discharge of 0.1 gpm/sq.ft.over the"design area"in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. • Minimum distance between residential sprinklers:8 ft. (2.4 m). NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers.Also refer to pages RES1-17 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data,the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction,and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. 2-1/4" (57.2 mm) diameter opening Sprinkler and is required in — Adapter Assembly the ceiling. (Protective Cap is removed for j....:i;,„,„„„„„,i,„„,„,„,„ installation--use Wrench 13619W Sprinkler n Wrench (Pa 13623W/Bww rtNo, is shown) Step 1; Carefully slide the wrench sideways around the deflector and pinsf f )0A 1/2" ratchet is required Step 2; Carefully press the wrench (not available from Viking). upward and turn slightly to ensure engagement with sprinkler wrench flats. Figure 1: Sprinkler Installation and Correct Use of Wrenches Form No. F_072607 Rev 15.1 Page 6 of 6 NIKING1(1 ® FREEDOM® RESIDENTIAL TECHNICAL DATA CONCEALED PENDENT SPRINKLER VK457 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1/2" — =_ (15 mm) NPT mmmit _._.---=_----_----___-- -_-j_._--—-= 2-9/16" l.�l.� 2-1/16" 2-1/8" 11111 ��lil���l (65 mm) 11111 (52 mm) ONO (54 mm) -- Maximum Minimum �- mm.mmom "MI 2-3/4" (70 mm) or Note: Upon sprinkler activation, the deflector descends 3-5/16" (84.1 mm) to approximately 13/16" (20.6 mm) below the sprinkler body Figure 2: Sprinkler Dimensions and Cover Installation �'\.�� CUJTO� DU NOT PAINT Qe � Z L o (--) v d y N Hi NG Identification of Custom Paint Color: All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates custom 3-5/16" (84,1 mm)-00--- color and will have a representative sample (a paint dot) of the paint on the label Figure 3: Identification of Custom Paint Color for Concealed Covers Figure 4: Square Cover Assembly 15394 Form No. F_072607 Rev 15.1 (Added 205 Temp and Footnote 3 in Table 1) 6341.6345 SES FIRE DEPT. INLET CONN. FLUSH TYPE) CROKER SINGLE INLET An inlet connection with 250 G.P.M. minimum inlet capacity to supplement the fire protection water supply. Provides 41kli abie unobstructed water supply. Flush round design enhances r' • appearance and provides unobstructed passage. . • •k .•r STANDARD EQUIPMENT: Cast Brass round plate with double � - } female adapter; plug and chain; branding as selected. _. •'l SPECIFY THREAD AND BRANDING. v ' BRANDING: "Standpipe", "Auto Spkr." 44 FINISH: Cast Brass Figure No. 6341 Figure No. 6342 OPTIONAL FINISH: PB-Polished Brass PC-Polished Chrome Round Plate Figure No. Size 6341 2 1/2 X 2 1/2 6342 3 X 2 1/2 6343 3 X 3 RESIDENTIAL FIRE DEPT. CONNECTION An inlet connection to supplement the water supply to a ,fes residential sprinkler system. 1. ' i STANDARD EQUIPMENT: 1 1/2" cast brass round plate assembly with integral pin lug swivel inlet. Hose thread inlet _ :i N. , swivel, 1 1/2" NPT female outlet on back of plate. Cast brass plug and brass chain. Overall outside Diameter 4 3/8". SPECIFY THREAD AND BRANDING. U/L LISTED. • BRANDING: "Auto Spkr." a FINISH: Cast Brass Figure No. 6345 OPTIONAL FINISH: PB-Polished Brass PC-Polished Chrome Page 6-12 ® TOLCO www.tolco.com a brandofNlBCD Revision 5/24/2001 Fig. 20 - Standard Pipe Strap Fig. 20S - Flush Mount Pipe Strap Data Table for Fig. 20S Size Range— 1/2" thru 8" pipe Material — Carbon Steel Dimensions •Weights Function — Recommended for supporting pipe Pipe A B C D Hole Max. Rec. Approx. Sizes Size Load Lbs. Wt./100 with fittings vertically or horizontally to walls or 1/2 41/8 5/16 27/8 3/4 7/16 410 21 ceiling. Fig. 20S will support pipe flush with 3/4 45/16 7/16 3 15/16 7/16 410 24 mounting surface. 1 49/,6 9/16 33/8 11/8 7/16 410 26 Approvals —Conforms to Federal Specification 11/4 415/16 11/16 33/4 11/2 7/16 410 30 WW-H-171 E, Type 26 and Manufacturers 11/2 53/16 13/16 41/4 15/8 7/16 410 33 Standardization Society SP-69, Type 26. 2 53/4 11/16 43/4 21/4 7/16 410 38 Finish — Plain 21/2 61/4 19/16 51/4 23/4 7/16 610 102 3 67/6 15/8 57/8 33/8 7/16 610 118 Note—Available in Electro-Galvanized and HDG 31/2 73/8 17/8 63/8 37/8 7/16 610 130 finish or Stainless Steel materials. 4 83/8 21/8 7 43/8 9/16 725 159 Order By— Figure number, pipe size, material 5 97/16 25/8 77/8 53/8 9/16 725 191 and finish 6 101/2 33/16 87/8 67/16 9/16 725 234 8 14 41/4 111/2 83/8 11/16 900 446 Data Table for Fig. 20 Dimensions •Weights Pipe Hole Max. Rec. Approx. Sizes A B C D Size Load Lbs. Wt./100 ' 1/2 37/6 3/4 31/16 15/32 7/16 410 16 A 3/4 4 13/16 31/8 15/16 7/16 410 21C ' • 1 49/16 7/8 33/8 11/2 7/16 410 26 1 /4 415/16 1 33/4 1 /8 7/16 410 3011/2 5/161641/4 21/8 7/16 410 332 53/4 1 /16 _ 43/4 2/8 7/16 410 3821/2 61/4 111/16 51/4 31/ 7/16 610 102ii11 < 3 67/8 2 57/8 33/4 7/16 610 118 31/2 73/8 21/4 63/8 41/4 7/16 610 130 4 83/6 21/2 7 43/4 9/16 725 159 5 97/16 31/16 77/8 513/16 9/16 725 191 6 101/2 35/8 87/8 67/8 9/16 725 234 8 14 45/6 111/2 9 11/16 900 446 Fig. 21 - "Tin Strap" Size Range— 1/2" thru 2" pipe Material — Carbon Steel ` Function — Light duty strap that attaches pipe or copper / tubing to horizontal or vertical structure. 4111(1/27.#. Finish — Pre-Galvanized ~• Note—Available with felt lining, order TOLCOTM Fig. 21 F. / Order By— Figure number and pipe size -- Main Office/Manufacturing Facility•1375 Sapp c1,Ave.•Corona,Ca,92879•Fh: 909.737.5599•Fax: 909.737.0330 36 Customer Servi ce•800.786.5266 www.totco.com CENTRAL H d . C a b . 11 -9 4 Close Sprinkler Hea a • ine r Central Sprinkler Company 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 Product Technical 3 , 6 & 12 Description Data H e a d Central Sprinkler Head Cabinets Model: Sprinkler Head Cabinet Sprinkle r are constructed of a metal enclosure Style: 3, 6 or 12 head with a hinged cover designed to HeadStandard Finish: Red enamel provide on-site storage of an emergency supply of sprinkler heads Mfgr. Source: Non-domestic and a sprinkler head wrench. Capacity: 3 sprinkler heads C a b i n e t NFPA 13 requires a representative 6 sprinkler heads number of each type of sprinkler 12 sprinkler heads head used in a sprinkler system to be Dimensions: stored in a cabinet on-site to allow for immediate removal and replacement 3 head-5"high x 7'/z"long x 2'/z"deep of sprinklers which may have 6 head-5"high x 14"long x 3'/a"deep operated or become damaged. 12 head-5"high x143/4" long x 5"deep Central Sprinkler Head Cabinets Weight: 3 head - 1.5 lbs. are manufactured of heavy gauge 6 head -2.3 lbs. steel with knock-outs to 12 head -4 lbs. accommodate either 1/2" or 3/" N.P.T. threaded sprinkler heads and are painted an attractive red enamel. They are available in three (3), six (6) or twelve (12) head capacity. No. 28-6.0 Close Installation Care & A Ordering Maintenance Information Central's Sprinkler Head Cabinet is The Cabinet, wrench, and stock of When placing an order, indicate the designed with two%s'diameter holes spare sprinklers should be inspected full product name. Please specify the for wall mounting or direct attachment at least quarterly. The following items quantity, model, style, capacity, and to the system riser with a strap-type should be checked: size. hanger. The Cabinet should be Sprinklers, wrenches, and hard- installed at or near the system control 1. The Cabinet should be readily ware for hanging are not supplied valve and must be stocked with an accessible, and not exposed to with the Cabinet. They must be adequate supply of spare sprinklers a corrosive atmosphere or ordered separately. and a sprinkler wrench. temperatures in excess of The stock of spare sprinklers 100°F/38°C. Availability and Service: Central should include sprinklers of each type sprinklers, accessories, and other and temperature rating as are 2. The stock of spare sprinklers products are available throughout the installed in the sprinkler system, in should include an adequate U.S. and Canada, and internationally the following quantities: number of each type and through a network of Central temperature rating. Sprinkler distribution centers. You Sprinklers Spare Sprinklers may write directly to Central Sprinkler In System Required 3. The stock of sprinklers must be Company, or call (215) 362-0700 for in good condition. the distributor nearest you. under 300 6 300-1000 12 4. A sprinkler wrench of the Guarantee: Central Sprinkler over 1000 24 appropriate type must be Company will repair and/or replace included in the Cabinet. any products found to be defective in The Cabinets are designed to material or workmanship within a accept both %"and %" N.P.T. period of one year from date of threaded sprinklers. For%" N.P.T. shipment. Please refer to the current sprinklers, leave the removable Price List for further details of the knockout in the hole. For%" N.P.T. warranty. sprinklers, insert a screwdriver blade from the front top of the shelf and Conversion Table: under the near bottom part of the 1 inch = 25.400 mm knockout annular ring. Press the 1 foot = 0.3048 M screwdriver handle down to remove 1 pound = 0.4536 kg the knockout ring. The hole, with the knockout ring removed, will accept a Conversions are approximate. %" N.P.T. sprinkler. CENTRAL Central Sprinkler Company 451 North Cannon Avenue, Lansdale, PA 19446 ©1994 Central Sprinkler Company Phone(215)362-0700 Printed in U.S.A. FAX (215)362-5385 Hd.Cab.2 CENTRAL Sign 1 -9 5 Close Signs THF 'OAT COM « AUTOMATIC SPRINKLERS For sprinkler systems & devices PEli •1 • :1� ati'ti��• �1 MIN DT Mil 143.ILO1 WM TIM LI 1H PM FL i{T ILT .1U1 �nln • a..H _.1-14:,•,.• n.a.• Ha H. •IL a a Manufactured by: Central Sprinkler Company •• 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 ProductMain prn sprinkler sprinkler control Open sprinkler drain Identification Description Test valve Triangular main drain Signs Water motor Central's Identification Signs are Water motor line designed to provide information to the end user about the sprinkler system Technical and it's components. They are available with a variety of wording Data combinations to meet the signing requirements of NFPA 13. The five basic types of signs are as Model: Sign follows: Style: Flat, rectangular Type A- Control Valve Sign Standard Finish: porcelain or mylar Type B - Multi-purpose Text Signs Size: Type A- 9" x 7" Type C - Cold Weather Sign Type B - 6" x 2" Type D - Fire Alarm Sign Type C- 73/a" x 1'/a" Type E - Hydraulic Calculation Sign Type D -9" x 7" The Signs are constructed of 18 Type E - 5" x 7" gauge steel or aluminum with a Weight: Type A-4.5 oz. porcelain enamel or printed mylar Type B - 0.5 oz. facing respectively. The signs have Type C-2.0 oz. corner holes or slots for easy attach- ment in the field. Type D -4.0 oz. Sign Type B is available with the Type E - 1.5 oz. following text options: Air control Installation Air control valve Air line Alarm test Alarm line Antifreeze system The Identification Signs are pro- Auxiliary drain vided with 1/8" diameter or larger holes Control (or slots) in the corners for easy Control valve attachment using standard hardware Drain chain, wire, plastic lock ties, or light Drain valve gauge metal strap (not included). Entire system From city main In this building In this section Inspectors test Main control No. 28-9.0 Close Sign -Type A Sign -Type D • Ordering THIS VALVE CONTROLS SUPPLY AUTOMATIC SPRINKLERS SPRINKLER a4Information T° ' FIRE - ALARM rill • • When placing an order, indicate MUST OPEN AT ALL WHEN BELL RINGS BE TIMES the full product name. Please TO BE HANDLED ONLY BY AUTHORIZED PERSON OR CALL specify the quantity and type. BY EMPLOYEE CARING FOR SPRINKLER SYSTEM IN CASE OF FIRE FIRE DEFT OR POLICE Hardware for hanging is not DO NOT SHUT VALVE UNTIL FIRE IS ENTIRELY OUT supplied with the Sign. It must be WHEN VALVE IS SHUT FOR EMERGENCY-REPAIRS-OR FIRE- ordered separately. NOTIFY: .r Availability and Service: REQUEST DIRECTIONS--RESTORE PROTECTION QUICKLY Central sprinklers, accessories, and other products are available The blank spaces on this sign may throughout the U.S. and Canada, be utilized to provide message and internationally through a flexibility. Simply add combinations of Sign -Type E network of Central Sprinkler sign Type B and Type C as desired. • HYDRAULIC-SYSTEM • distribution centers. You may This Building is Protected by a write directly to Central Sprinkler Sign -Type B Hydraulically Designed Automatic Company, or call (215) 362-0700 Sprinkler System • • for the distributor nearest you. AUXILIARY DRAIN Location Guarantee: Central Sprinkler No. of Sprinklers Company will repair and/or • • replace any products found to be Basis of Design defective in material or 1.DENSITY GPM/SQ.FT. workmanship within a period of Sign -Type C 2 DESIGNED AREA OF DISCHARGE SQ.FT. one year from date of shipment. System Demand Please refer to the current Price FRONT List for further details of the • • 1.WATER FLOW RATE GPM VALVE 2.RESIDUAL PRESSURE AT THE PSI warranty. VALVE MUST BE OPENED IN CASE OF FIRE BASE OF THE RISER SHUT ALSO DURING SUMMER MONTHS SHUT Conversion Table: • • 1 inch = 25.400 mm BACK 1 foot = 0.3048 M • 1 pound = 0.4536 kg AND MUST BE KEPT OP EN EXCEPT DURING WINTER MONTHS, `conversions are approximate. WHEN VALVE IS TO BE CLOSED AND PIPES DRAINED. CENTRAL _,..„ Central Sprinkler Company 451 N. Cannon Avenue, Lansdale, PA 19446 ©1995 Central Sprinkler Company Phone (215)362-0700 Printed in U.S.A. FAX (215) 362-5385 Signs.1