HomeMy WebLinkAboutF16-0037_FP1 plans approved.pdf SITE PLAN NOTES: Hydraulic Information 479 1.THIS DETAIL IS SHOWN FOR NFORMATION PURPOSES ONLY AND Remote Area 1 ITS PRESENCE ON THIS PLAN DOES NOT CONSTITUTE ANY INCLUSION OF WATER FLOW I N F OCCUPANCY CLASSIFICATION I Residential FROMUNDERGROUND PIPINGOINSTALLATION. NSTD L TIIE N.THIS CONTRACT.THE TO BEGIN 51Fi1'IC: tspsl 0j, , DENSITY 0.100gpm/ft2 for 900.00ft2(Actual 313.60ft2) 7JTITI 1rs ++� sills .a'.• •t RESPONSIBLE FOR THE UNDERGROUND WORK IS TO PROPERLY RESIDUAL BBpsi TOTAL HEADS FLOWING 3 _�� .,.r, ===� � • Vail Fire&Emergency Services INSTALL,TEST,AND FLUSH THE PIPING PER NFPA PER 07/19/16 THE LOCAL AUTHORITIES BEFORE ANY CONNECTION OF FIRE FLOW: 1309.5gpm K-FACTOR 4.9 PROTECTION SYSTEM DEVICES. TOTAL WATER REQUIRED 44.97 R58.6 INSULATION RATING TOTAL PRESSURE REQUIRED 81.195 PIPE TO BE RAN AS LOW AS POSSIBLE r NO INSULATION TO BE BETWEEN BOTTOM OF PIPE AND DRYWALL SAFETY MARGIN (psi) +16.785 (117.1%) A. - 3 HEAD CALCULATION PER VAIL FIRE DEPARTMENT DESIGN REQUIREMENTS +.��!!!,!!.l�-�� ,�..n" field evaluation of this bath roo is required. 1 HALL VK457 geliggellele Se . / i size? p cket doors? r BEDROOM �+� • �'+ ".!.!.lMRE'-": .Rl.Rl.Rlti STA / / 0 0 0 A37i elluJ.i.. a�a s2 REMOTE AR EA LOCATION ifi i / :.:. �! -1• ' • _6'-2'/s _ AREAOF WORK RESIDENTIAL o v a N a1I _ HAZARD MED - � LO'., ! _ W 4,542 FT2 SYSTEM ; fi . //// pp A MASTER MASTE 7-2 V I I BATH rrDILET HALL DINING IUTGHo a O V .I i1'.IPJ.�1% LIVING ROOM I a .0 4 a UESTBATr 'pp . Osla 8'-6 Fn fi 1'CPUC `1 MATER CLOS%1Ill 8'-s D' - SEWING R000M •0-3/ 3/4'CPVC 4'-8% 0 0 TRY\' o * �' 6 �,_ 1., ii1 _13r� B H Dal 3 3 o M TA CPI S+7 n , .{�� r g� ,1'-71A 0 0V OM A 04 0 a 0 -11%3'-3 f 1 ��, � 7% 1'-' •3'-4 tial s'-b 3 _�.I� . •- -mss' •� I 1 I O r �}QQ r � '1,_1 © 1, •S -�:in • . STAIR N0" �� Ily •�: 3' 12j d !R-MUD ROOM - AUTO GARAGE (BY OTHERS) !' • ,III It o ; OCO�P BY i as g mh i'-2 ` EXISTING CITY VAIN k ��11111 r 01• N 4 111MIM. t L. V. m1' a' ELEV. TAIR SECTION VIEW t...I 0 3'_2 BATH I II DINING • HALL_ 17-- 0 SCALE 1/8" = 1�-0" MEADOW_ANE i a'-8' 7 DM' I . OM - 0 D ` o 2a �o ..._ 0 of �I EQUIPMENT IN MECHANICAL-ROOM MAM R LENA -,r.,� rJ CLOS. ...3 • 6 CLOS. • BATH r r a g 0 Al QQ , 'i_ I - o 03t, I 03A OM _ o o 4 -4-- o a T o - SITE PLAN 3'-7 p m 8'-2% %.0' 0. '-10 8.-EPA ° 4'48 SM 0 a P � ya p 7' " NC SCALE 1- 6 4 6'-8'% CkO\' `UNDRY 2'_3. r BATH 4'-8 PANTRY o ® C] 0 MASTERBEDROOM � KITCHEN P ' ' 0to D3 Fa BATH A rMAIN DRAIN - 8 0 ,L 1 0 0 111111 0 0 0 B DR❑❑ M 1■itmui BEDROOM D 4'-6 _1 / 1: . DOG ■� \-FLOWSWITCH R D Q IYI (MR EO 6Y OiEHRS) 1'CONBRACO SERIES 40-100 cDOUBLE CHECK \ RACKF OW DEVICE 01I. I. +0..Ir fr\,'. \ FIRE PROTECTION PLAN - MAIN LEVEL <N)\ FIRE PROTECTION PLAN - UPPER LEVEL EXCEL FIRE PROTECTiONTO 1° T ^ STARTAT2"UG. , Li PIPETYPE AND SCHEDULE OF THICKNESS i '•i 2INBYOTWATER 1"DfeDisPipe C7IWCRETESLAB ONGRADE TABLE 2c. Dimensions and Physical Characteristics of Copper Tube:TYPE M SCALE 118"= 1'-0" SCALE 118"= 1'- " MAIN BY OTHERS To Safe Discharge Nominal Dimensions,inches _ Calculated Values(basad on nominal dimensions} 0NODE AT SUPPLY CONNECTION Nominal or Cross Weight WeightContents of Tube PLAN NOTES: Standard Outside Inside Wall Sectional of Tube Only, of Tute&Water, per lirear ft Size,inches Diameter Diameter Thickness Area of Bcre. pounds pounds Cu ft Gal sq inches per linear ft pea linear ft RISER DETAIL 1.ALL ROOMS AND AREAS ARE RESIDENTIAL HAZARD UNLESS NOTED OTHERWISE. • 3/6 ` .500 .450 _ .025 :159 .145 .214 _ .00110 .00826 0 2.ALL AREAS ARE SLOPED UNLESSNOTED OTHERWISE. `la .525 .569 .028 .254 .204 .314 .00176 .0132 _ SCALE: NONE 3/A .875 .811 .032 .517 .328 .551 .00359 .0269 3.ALL PIPE ELEVATIONS ARE AT 10'0 A.F.F. UNLESS ON SLOPED CEILINGS 1 -- 1.125 1.055 .035 .874 .465 .843 .00607 .0454 approved a s noted ■ 4. PENDENT SPRINKLERS IN CEILINGS ARE TO BE ALIGNED WTH LIGHTS. 111, 1.375 1.291 .042 1.31 .682 1.25 .00910 .0681 • : �i 1'/a 1.525 1.527 .049 1.83 .940 1.73 .0127 .0951 5.NO NS IN BATHROOMS AND CLOSETS UNLESS NOTED OTFERWISE PK • : 2 2125 2.009 .058 3.17 1.46 2.83 .0220 .165 evaluate bathroom sizes _ 2':'- 2.525 2.495 .065 4.89 2.03 4.14 .0340 .254 . - • -----•---•-, -- • = 3 3.125 2.981 .072 6.98 2.68 5.70 .0485 .363 • ' 7. MAXIMUM SLOPE IS Bf12 UNLESSNOTED OTHERWISE. - 3': 3.525 3.459 .083 9.40 3.58 7.64 .0653 .488 .. : related to sprinkler = 8.SPRINKLERS UNDER GLASS OR CIRECT SUN RAY EXPOSURE TO RADIANT HEAT 4 4.125 3.935 .095 12.2 4.66 9.83 .0847 .634 • tp _ Finish Ceiling SHALL EE INTERMEDIATE TEMPERATURE CLASSIFICATION. 5 5.125 4.907 .109 18.9 6.66 14.8 .131 .982 5'-9 a _ DIN 9.SPRINKLERS INSTALLED WHERE MAXIMUM CEILING TEMPERATURES ARE 151°F 6 6.125 5.881 .122 27.2 ` 8.92 20.7 .189 1.41 a) 0-2 0 requirements . 0355 AND 22t F,FOR EXAMPLE-STEAM ROOMS AND SAUNAS,SHALL BE 8 8125 7.785 .170 47.6 16.5 �.1 .331 2.47 7-8 �� 6VK457,'f�Thread HIGH TEMPERATURE RATED SPRAY SPRINKLERS. 10 10.125 9.701 .212 73.9 25.6 57,5 .513 3.84 " 1'e \ , - c? 8-0 Freedom Series W Orifice 10.ALL SPRINKLER DROPS TO BE%TYPE-M COPPER,1'-0 INLENGTH UNLESS 12 12.125 11.617 .254 106 36.7 82.5 .736 5.51 • 111�}4 0 03� 0 K=4.9 White SSP 160`F Sprinklers NOTED OTHERWISE- y g /7 Witt Concealed White Escutcheons �• 03Jra- [V 03. iq 6-5'% 03% 03� 3'-8 TA I ELEV MECH 5'-6 10'-0 ID In Indicated Areas. o STAIR 5 "� ZO _Vr SPRINKLER DETAIL GENERAL NOTES: o=i ❑oN 8'-5'� 41! ', SPRINKLER SYMBOL 1.ALL PIPE AND HANGER INSTALLATION AND TESTING SHALL CONFORM TO 11. IF FIELD CONDITIONS RESULT IN A CHANGE TO THE SHOP DRAWINGS ABOVE (9 MINIMJM REQUIREMENTS OF N.F.P.A. 13 2010,!RC.2012 AND LOCAL INSTALLATION IN ANY WAY, CONTACT THE PROJE:T ENGINEER TO VERIFY 1'-10 'A � 6-0 PROPOSED CHANGES ARE COMPLIANT WITH NFFA 13D REQUIREMENTS AND • . ELEV. _' E• AUTHORITIES HAVING JURISDICTION. PER HYDRAULIC DESIGN. d cfl -o ao o ' to _D e? 2.ALL MATERIALS AND DEVICES USED ON THIS PROJECT TO BE UL LISTED 12.THE INSTALLER TO FEILD VERIFY ANY MECHANICAL OR PLUMBING 4'-,= o 7'-4+ ANDIOR FM APPROVED FOR USE IN FIRE SYSTEMS THAT IS IN ANY WAY OBSTRUCTING THE SPRAY PATTERN OF THE FIRE ' ' 1 - AUTO GARAGE T ``' 3.SEE KTACHED MATERIAL DATA SHEET FOR ALLAPPLICABLE MATERIALS PROTECTION SYSTEM AND INFORM THE PROJECT ENGINEER SO PROPER �� ' o, Wood Screw#12 x 1'/" SPACING CAN BE CALCULATED • 3_8 7_71h o fi o a ,_ - - f AND EQUIPMENT USED IN THIS PROJECT. r , fJ Wood Screw#12 x 1%" Co 4.ALL PIPE 314"TO BE COPPER WITH COPPER FITTINGS. 13.ALL OUTSIDE UNDERGROUND WORK,DESIGN,INSTALLATION,TESTING MUD ROOM Pipe Strap \ ' . \ \ \ ` AND FLUSHING OF PIPINGS.IS TO BE BY OTHER CONTRACTORS. 03l Wood Screw#12 x 1Y," Pie Pipe Strap \ '' Pipe \ \ \ V. Pie 5.ALL RI.3ERIPUMP PIPE TO BEMEGA THREAD WITH THREADED C.I.FITTINGS. 14.ANYANDALL PAINTING OR PAINT PREPARATION OF PIPING TO BE BY OTHERS i p Pipe �. p MECH ROOM add �$,-1 .'',Z RV GARAGE \ \ \ \ •. / 15.ANYANDALLACCESS PANELS FOR VALVE AND DEVICE ACCESSIBILITY Wood Screw#12 x 1Y.," \ \ \ iii \ \ \ 6.ALL PIPE AND HANGER DIMENSIONS ARE CUT LENGTH UNLESS •. 7 Y715 ` f IS TO BEBY OTHERS. sn , NOTED OTHERWISE AND COAPLY WITH NFPA 13D./ 16.THE FIRE PROTECTION CONTRACTOR SHALL NOT BE HELD RESPONSIBLE 40 � ` a 1�f0 / / A / k„,/ / / • f / \ ti i; Pipe Strap \ \ \ 7.PROJECT SPECIFICATIONS WERE NOT PROVIDED TO THE INSTALLING SHOULD THE NOTED FLOW TEST VALUES NOT BE SUPPLIED AT THE grif T-0Pipe Strap POINT 0=CONNECTION NOW CR IN THE FUTURE.DUE TO THE POSSIBILITY S° ' / / / / / ' / / 2' / / / / / \ \ \ ' \ \ \ CONTRACTOR FOR REVIEW.THEREFORE THE PROJECT IS CONDIDERED Alazg O OF DETERIORATING WATER SUPPLIES. ,i-1- ;3 -\ so ,� m 6 / / / / F / / / / / / / / �' ,�t� a ii9 r +o _ n Wood Joist or Beam/Block Wood Joist or Beam Block Wood Joist or BeamlBlock DESIGN BUILD. Joist or Beam/Block 17. FIELD LOCATE DISCHARGE FROM ALL MAIN IAUXILARI'DRAINS. 03/, 03A 8.THIS CONTRACT IS TO BEGIN FROM A LEVEL,CAPPED COPPER LINE 0 18.BUILDING TO MAINTAIN 400+TO PREVENT FREEZING. 6'-6 • 161-,21h. _ _ r - . • -. , • . [ I . L INSTALLED BY OTHERS INSIDE THE BUILDING. 0 19.SPRINKLER SYSTEM DESIGNEC TO NFPA 13D AND VAIL FIRE DEPARTMENT • HANGER DETAIL 9.SPRINKLERS TO BE INSTALLED IN ACCORDANCE WITH NFPA 13D AND PER THE DESIGN REQUIREMENTS. 4� LOCAL AHJ.ALL SPRINKLERS TO BE INSTALLED PEP SPRINKLER DETAILS. HANGER SYMBOL \ 10.TAMPER SWITCHES FOR SUCTION SHUT-OFF VALVE&ISOLATION BALL VALVE TO BE PROVIDED BY OTHERS. FIRE PROTECTION PLAN - LOWER LEVEL Sprinkler Legend THIS DRAWING AND THIS DESIGN ARE THE N Proposed System Design Criteria PROPERTY OF EXCEL FIRE PROTECTION SCALE 118" =.-- 1'-0" ALAN W. B RU CH Symbol Manufacturer SIN Quantity K-Factor Type Size Response Firish Temperature 81505 AND ARE NOT TO BE COPIED OR TO EXCEL FIRE PROTECTION THIS SYSTEM CONFORMS TO:NFPA 130 2013 AND LOCAL AUTHORITIES HAVING JURISDICTION • Viking Corporation VK457 35 4.9 Pendent 1/2 Quick White 165`'F BE USED, DIRECTLY OR INDIRECTLY, BY N I C ET LEVEL III ANYBODY WHOMSOEVER,WITHOUT THE HAZARD CLASSIFICATION:RESIDENTIAL Total = 35 WRITTEN CONSENT OF EXCEL FIRE 2264 G Road WATER BASED SYSTEMS COMBUSTIBLE CONSTRUCTION,IBC CONSTRUCTION TYPE V B,IBC OCCUPANY TYPE R PROTECTION GRAND JUNCTION, COLORADO 81505 CERTIFICATION NO. 108440 DESIGN DENSITY:.10 gpmisq.ft.OVER 900 sq.ft. 2264 G ROAD GRAN)JUNCTION,CO MAX.AREA PER SPKLR:256 sq.ft.(16'X 161 (970)434.4803 WATER SUPPLY:STATIC:98ps1 RESIDUAL:88ps1 FLOW:1309.5gpm JUNE 14. 2�15 WET SYS. DRY SYS. ANTI-FREEZE PROJECT BY:EXCEL FIRE PROTECTION DATE:03130I207 6 NAME MORRIS RESIDENCE dee.....ae,44e4.4. . SYSTEM DEMAND C SUPPLY CONNECTION: REFERENCE HYDRAULIC INFORMATION ON DRAWING X r+ r TOTAL SQUARE FEET:4,542 Revisions JOB NO. DATE SCALE 4 �? ��F,A fT ]ISI F SiGNATURt O SAME 15-092 07/1r2O16 NOTED ADDRESS VAIL, co STATE CERT# DRAWN CHECKED DRAWING NO. CONTRACT 16-5-00496 JKS WITH GILLETTE CONSTRUCTION, LLC FP-1